Code Alarm 3000 Instruction manual

image

Contents

1. certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le Minist re n assure toutefois pas que le mat riel fonctionnera la satisfaction de l utilisateur Avant d installer ce mat riel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de entreprise locale de t l communication Le mat riel doit galement tre install en suivant une m thode accept e de raccordement Dans certains cas les fils int rieurs de l entreprise utilis s pour un service individuel ligne unique peuvent tre prolong s au moyen d un dispositif homologu de raccordement cordon prolongateur t l phonique interne L abonn ne doit pas oublier qu il est possible que la conformit aux conditions nonc es ci dessus n emp che pas la d gradation du service dans certaines situations Actuellement les entreprises de t l communications ne permettent pas que l on raccorde leur mat riel des jacks d abonn sauf dans les cas pr cis pr vus par les tarrifs particuliers de ces entreprises Les r parations de mat riel homologu doivent tre effectu es par un centre d entretien canadien autoris d sign par le fournisseur La compagnie de t l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais onctionnement Pour sa propre protection l utilisateur doi
2. 3 keys at the same time for 2 seconds Some smoke detectors require entering a keypad command to reset them after an alarm Press then hold down the 4 key for several seconds If the smoke has cleared the smoke detector will reset and the fire zone light will go out when the 4 key is released If the smoke has not cleared from the detector open a window or door and fan clean air into the detector and try resetting again Ready light ON system is ready to be armed Ready light OFF open zone Zone must be closed or bypassed before arming Ready light flashing with Armed light ON indicates access code 9 16 programming Bypass light comes ON when you bypass a zone To bypass a zone press 1 Master Code and then the zone s you wish to Bypass Enter 01 for zone 1 08 for zone 8 16 for zone 16 Press to return to ready Trouble light ON means there is a fault onthe system Press any key to silence keypad beeping Press then 2 to display trouble type one or more zone lights will come ON to indicate the type of trouble 1 Battery A C Power Day loop Telephone line Communicator Bell circuit Smoke detector circuit Clock needs resetting Press t when an error is made in entering code then enter code again to return to ready state after using commands 9 10 11 12 13 14 15 8 16 ZONE BY PASSING Press 1 press the zone you wish to by
3. the feature is being enabled and will sound one long beep if the feature is being disabled Press to return to Ready Alarm Test Enter 6 Master Code 8 for a 2 second test of the keypad lights keypad sounder and alarm bells Press to return to Ready Keypad Zones There are three zones which can be activated from the keypad They are activated by pressing two keys at the same time and holding them for 2 seconds These zones may or may not be active on your keypads depending on how your installer has programmed them F Keypad FIRE zone Pressing this key for 2 seconds will activate the keypad fire zone and the bell siren output will pulse ON and OFF This zone is annunciated by the Fire light on the keypad A Keypad AUXILIARY zone Pressing this key for 2 seconds will produce a series of beeps on the keypad along with the transmission To confirm transmission the keypad sounder will beep 6 times P Keypad PANIC zone Depending on how your installer programs the panel pressing this key for 2 seconds may produce a completely silent alarm or an audible alarm along with the transmission If programmed as audible the alarm bell will ring Testing It is recommended that the system be tested on a weekly basis NOTE Perform tests in the off peak hours such as early morning or late evening 1 2 3 7 8 Inform the monitoring station that you are testing your system Disarm the system Ready li
4. when access is needed to part of the protected area Also damaged wiring or contacts on a zone may be temporarily bypassed until repairs can be made so that the panel can be armed To bypass zones enter 1 and the zone numbers to be bypassed i e 0 1 for zone 1 1 6 for zone 16 Ifthe 0 key is pressed twice instead of a zone number all zone bypasses will be removed If the 9 key is pressed twice the last group of zones which was bypassed will be recalled Press to return to Ready For security reasons your installer may prevent the bypass command from operating on certain zones The Bypass light is ON as long as at least one zone is bypassed Do not unintentionally bypass zones when arming Zone bypasses are automatically cancelled each time the panel is disarmed and must be re applied before the next arming Trouble Display The PC3000 continuously monitors a number of possible trouble conditions If one of these conditions occurs the keypad sounder will beep quickly twice every 10 seconds and the keypad Trouble indicator will light Pressing any key on the keypad will silence the beeper but the Trouble light will remain on until the trouble condition is cleared If you cannot determine the cause of the trouble condition call your installer for assistance Press the then 2 keys to display the type of trouble The zone lights indicate the type of trouble condition Zone Light Trouble 1 Defe
5. NLESS PROGRAMMED BY INSTALLER Colored labels on keypad door indicate which keys are active Programming Access Codes Up to 15 access codes in addition to the Master Code can be entered from the keypad Press 5 and Master Code The Program light will flash and the zone lights will show which codes have already been programmed To enter a new code or change an existing code first press the code number 0 1 to 1 6 and then enter your 4 digit code To erase a code press instead of a 4 digit code Note that the and keys cannot be used in a code Press to return to Ready Quick Arm Feature When the Quick Arm feature is enabled the panel may be armed simply by entering 0 instead of a 4 digit code The 0 command will not disarm the panel Enter 6 Master Code 4 to turn ON and OFF the Quick Arm feature When the command is entered the keypad will beep 3 times if the feature is being enabled and will sound one long beep if the feature is being disabled Press to return to Ready Door Chime Feature The door chime feature is used while the panel is disarmed to provide a tone from the keypad each time a door or window is opened or closed The doors and windows which will provide this indication are programmed by your installer Enter 6 Master Code 6 to turn the door chime feature ON and OFF When the command is entered the keypad will beep 3 times if
6. System Reference Zone Area Type 1 NO 0c BR W ND 8 Fire Zone Keypad Zones Keypad Zone F Fire Keypad Zone A Auxiliary Keypad Zone P Panic Access Codes Access Code Assigned To Access Code re re re re re ON DAF ON n Oo a KF ND O re Entrance and Exit Delays Entry Delay seconds Auxiliary Entry Delay Exit Delay seconds Auxiliary Exit Delay Monitoring Station Account Number Phone For Service Call Phone Assigned To seconds seconds A Word About Your System The PC3000 Security System has been designed to give you the greatest possible flexibility and convenience Read this manual carefully and become familiar with the operation of your Security System Your installer will tell you which commands listed in this manual apply to your system Fill out the System Reference sheet in this manual and store it in a safe place for future reference The label provided for the nside of the keypad door can be used to record which sensors are on each zone Important Note Remember that no security system can prevent emergencies It is only intended to alert you in case of an emergency and should not take the place of prudent security practices or life and property insurance It is important to test your system every week To do this first inform the monitoring station that you are testing your system Then with the system disarmed activate all detection sensors one at atime and o
7. bserve the zone light come on at the keypad as each sensor is activated Perform a bell test by entering 6 Master Code 8 with the system disarmed The PC3000 can be programmed at the time of installation to automatically perform a test transmission to the monitoring station on a regular basis If the system has not been programmed for this automatic test call the monitoring station for instructions on how to perform a test transmission Don t forget to inform the monitoring station when you have finished your test Check to see if the Trouble light is on when arming the system See the Trouble Display section in this manual for a description of the different trouble conditions Contact your installer for assistance if the trouble condition cannot be located and corrected How Your System Works Your PC3000 Security System is made up of a control panel one or more PC3000RK keypads and various detectors and sensors The control panel will be mounted out of the way in a utility room or basement The metal cabinet contains the system electronics fuses and stand by battery There is normally no reason for anyone but the installer to have access to the control panel The keypad s have an audible indicator display lights and command entry keys The keypad is used to send commands to the system and to display the current system status Keypads are mounted in convenient areas close to the exit entry doors The security system has up to eig
8. ctive Stand by Battery 2 AC Power Failure see NOTE below 3 Day Zone Trouble 4 Telephone Line Problem 5 Unsuccessful Communication Attempt with Monitoring Station 6 Bell Circuit Failure 7 Smoke Detector Circuit Trouble 8 Loss of Time on System Clock Press to return to Ready NOTE The keypad buzzer will not sound for AC failure until there is also a low battery condition The Trouble light will come ON as soonas AC fails and will remain on until AC restores Smoke Detector and Fire Alarm Reset If your system is equipped with smoke detectors or other fire alarm detectors use the following instructions for resetting an alarm Before resetting a fire alarm signal be sure you know the source of the alarm and that there is no danger see Evacuation Planning elsewhere in this manual The system bell siren alarm signal pulses 2 seconds ON and 2 seconds OFF when the alarm is generated from the fire circuit The transmission to the monitoring station is delayed by 30 seconds The alarm may be silenced and the transmission delayed for 2 minutes by pressing any number key on the keypad If the detector causing the alarm is reset before the 2 minute delay expires no further alarm will occur If the detector is not reset at the end of the delay the alarm will start again and the transmission will occur in 30 seconds if a keypad key is not pressed An immediate fire alarm signal and transmission is generated by holding down the 1 and
9. e replaced every three years For other system devices such as smoke detectors passive infrared ultrasonic or microwave motion detectors or glassbreak detectors consult the respective manufacturer s literature for testing and maintenance Fire Safety in the Home Most fires occur in the home and to minimize this danger it is recommended that a household fire safety audit be conducted and a family escape plan be developed Household Fire Safety Audit 1 Are all electrical appliances and outlets in a safe condition Check for frayed cords over loaded lighting circuits etc If you are uncertain about the condition of your electrical appliances or household service have a professional evaluation Are all flammable liquids stored safely in closed containers in a well ventilated cool area Cleaning with flammable liquids should be avoided Are fire hazardous materials such as matches well out of reach of children Are furnaces and wood burning appliances properly installed clean and in good working order Have a professional evaluation Family Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly It is thus very important that a family escape plan be developed and rehearsed 1 2 Every family member should participate in developing the escape plan Study the possible escape routes from each location within the house and since many fires occur at night special attenti
10. er expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd Digital Security Controls Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify orto change this warranty nor to assume for it any other warranty or liability concerning this product Warning Digital Security Controls Ltd recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected Printed in Canada 29000664 R1 1994 Digital Security Controls Ltd October 7 1994 INSTRUCTION MANUAL PC3000 WITH PC3OOORK KEYPAD Department of Communications Notice NOTICE The Canadian Department of Communications label identifies certified equipment This certification means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of he local telecommunications company The equipment must also be installed using an acceptable method of connection Insome cases the company s inside wiring associated with a single line individual service may be extended by means of cer
11. ght should be ON Perform a battery bell test by pressing 6 Master Code 8 The alarm will sound for about 2 seconds If a trouble occurs after the test press 2 to view the trouble condition Activate each sensor in turn For example open a door or window Observe the zone light come ON as each sensor is activated The zone light will go OFF as each sensor is restored to normal door or window is closed Press the F key The signal will sound in a pulsed mode Arm then disable the panel to silence the signal Repeat this test by pressing the A and P keys in turn Remember the A key does not ring the bell and the P key may not be programmed for an audible signal If the fire zone is used activation will cause the signal to sound in a pulsed mode CAUTION Do not use open flame or burning materials to test a smoke detector Contact your installer for information on safe methods to activate a smoke detector Should your system fail to operate properly call your installer for service When testing is complete call and advise the monitoring station Maintenance With normal use the system requires minimum maintenance The following should be observed 1 2 3 Do not wash the keypad with a wet cloth Light dusting with a barely damp cloth should remove normal accumulations of dust The battery bell test is designed to determine battery condition however it is recommended that the stand by battery b
12. ht zones or areas of protection Each zone used will have connected to it various sensors such as door or window contacts motion detectors glassbreak detectors and vibration or shock sensors When a sensor is in alarm a keypad light will be on to indicate which zone is in alarm Master Code The 4 digit Master Code is used for arming and disarming the system for programming additional access codes and for changing other features The Master Code will be supplied to you by your installer All Keypad entries are made by pressing one key at a time and may be changed by you at any time if the installer selects an option For additional access codes see Programming Additional Access Codes Arming Close all protected doors and windows and stop movement in areas covered by motion detectors If the Bypass light is ON be sure zones are being intentionally bypassed before arming the system see Zone Bypassing Check to see that the Ready light is ON all zones are closed The system cannot be armed unless the Ready light is ON Enter a 4 digit access code As each digit is entered the keypad sounder will beep Once the correct access code is entered the Armed light will come ON and the keypad sounder will beep quickly If the access code was entered incorrectly or the Ready light was not ON the keypad sounder will beep steadily for 2 seconds When the correct code is entered and the system is armed exit through the door indicated b
13. on should be given to the escape routes from sleeping quarters It is essential that escape from a bedroom be possible without opening the interior door Consider the following when making your escape plans e Make sure that doors and windows that open to the outside are easily opened Ensure that they are are not painted shut and that their locks operate smoothly f opening the exit or using the exit is too difficult for children the elderly or handicapped plans for rescue should be developed This includes making sure that those who are to perform the rescue can promptly hear the fire warning signal e f the exit is above the ground level an approved fire ladder or rope should be provided as well as training in its use e Exits on the ground level should be kept clear Be sure to remove snow from exterior patio doors in winter outdoor furniture or equipment should not block exits e The family should have a predetermined assembly point where everyone can be accounted for for example across the street or at a neighbour s house Once everyone is out of the house call the Fire Department A good plan emphasizes quick escape Do not investigate first or attempt to fight the fire and do not attempt to rescue belongings or pets as this takes up valuable time Once outside do not re enter the house Wait for the fire department e Write the plan down and rehearse frequently so that should an emergency arise everyone will kno
14. pass Press to return to Ready Arm system PROGRAMMING USER CODES Press 5 Master Code then press 01 through 16 for the user code you wish to program then enter a 4 digit code Press to return to Ready INSTANT ARM Press 9 before any user code arms system without entry delay Arm Interior Press Quick Exit Press Quick Arm Press Reset Detectors Press Noonan A CG 7 amp NOT NOT NOT IN IN IN USE USE USE PRESS KEY FOR 2 SECONDS TO ACTIVATE TEST SYSTEM WEEKLY nen PC3OOORK TS When ON in the normal operating mode the Zone Lights indicate an open zone eg open door window etc Refer to zone chart on keypad door for zone information Armed light will come ON indicating system is armed Ensure Ready light is ON enter 4 digit access code Armed light flashing with Ready light indicates access code 9 16 programming Memory light ON means an alarm has occurred To display zone that caused alarm press then 3 Zone light will come on indicating which zone caused the alarm Fire light is ON when a detector on the fire loop is in alarm Press any key within 30 seconds of first alarm to get 2 minutes to reset smoke detectors Press F for 2 seconds to activate FIRE transmission Press A for 2 seconds to activate an AUXILIARY transmission Press P for 2 seconds to activate PANIC transmission THESE BUTTONS WILL NOT FUNCTION U
15. t s assurer que tous les fils de mise la terre de la source d nergie lectrique des lignes t l phoniques et des canalisations d eau m talliques s il y en a sont raccord s ensemble Cette pr caution est particuli rement importante dans les r gions rurales AVERTISSEMENT L utilisateur ne doit pas tenter de faire ces raccordements lui m me il doit avoir recours un service d inspection des installations lectriques ou un lectricien selon le cas L indice de charge IC assign chaque dispositif terminal indique pour viter toute surcharge le pourcentage de la charge totale qui peut tre raccord e un circuit t l phonique boucl utilis par ce dispositif La terminaison du circuit boucl peut tre constitu e de n importe quelle combinaison de dispositifs pourvu que la somme des indices de charge de l ensemble des dispositifs ne d passe pas 100 L Indice de charge de ce produit est 42
16. tified connector assembly telephone extension cord The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment User should ensure for their own protection that the electrical ground connections of the power utility elephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas CAUTION Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate The Load Number LN assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100 The Load Number of this unit is 42 AVIS L tiquette du minist re des Communications du Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme
17. w what they are to do Revise the plan as conditions change for example when there are more or fewer family members in the home or if there are changes to the house e Make sure your fire warning system is operational by conducting weekly tests as noted elsewhere in this manual If you are unsure about system operation contact your installing dealer t is recommended that you contact your local fire department and request further information on home fire safety and escape planning If available have your local fire prevention officer conduct an in house fire safety inspection Limited Warranty Digital Security Controls Ltd warrants that for a period of twelve months from the date of purchase the product shall be free from defects in materials and workmanship under normal use and that in fulfilment of any breech of such warranty Digital Security Controls Ltd shall at its option repair or replace the defective equipment upon return of the equipment to its repair depot This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Controls Ltd such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties wheth
18. y your installer as the exit entry door The exit time may be changed by your installer please refer to the Quick Arm feature Auto Bypass Option Home Away Arming This feature if selected by your installer will allow you to arm your system with any valid access code and the system will automatically bypass the interior zones if those interior zones have been designated as home away zones by the installer When activated the Bypass light will come ON If you exit within the allowed exit time the system will automatically reactivate the interior zones This feature is designed to save the user from having to manually bypass interior zones each time they wish to arm the system and remain at home In residential applications where the system has been armed and the interior zones are automatically bypassed the interior zones can be reactivated from a keypad outside the interior zones protection area e g a bedroom Toreactivate the interior zones press then 1 and the Bypass light will go out Entry Delay Off Arming If you wish to arm your system and eliminate the entry delay enter 9 before your access code The Armed light will flash as a reminder that the system is armed and has no entry delay An entry through any zone programmed as a delay zone will create an instant alarm Disarming Enter the premises only through the door indicated by your installer as the entry door The keypad sounder will be ON Go to the ke
19. ypad and enter the 4 digit access code If an error is made entering the code press the key and enter the code again The Armed light will go out and the keypad sounder will stop The correct access code must be entered before the allowed entry time expires The entry delay time may be changed by the installer If an alarm occurred while the panel was armed the Memory light and the light for the zone which caused the alarm will start to flash and will continue flashing for 2 minutes At the end of 2 minutes the keypad lights will stop flashing and the keypad will return to the normal Ready condition If youreturn home and find an alarm has occurred while you were away itis possible that an intruder may still be on the premises Go to a neighbour s and if your system is monitored call the monitoring station They will advise what action has been taken as a result of the alarm and whether the premises are safe to enter If your system is not monitored call the local police to investigate Alarm Memory Display If the Memory light is on an alarm has occurred since the last time the panel was armed The alarm memory will automatically be displayed when the system is disarmed see Disarming Press the then 3 keys to display which zone caused the alarm The alarm memory will be cleared when the panel is re armed Press to return to Ready Zone Bypassing Bypassed zones do not cause an alarm Use zone bypassing

Download Pdf Manuals

image

Related Search

Related Contents

Emerson EZH and EZHSO Series Pressure Reducing Regulators Drawings & Schematics  Rotinas Limpas nas Operações das Indústrias  1 - BIANCHI MARE` SpA  1 - Ibratele  Kit motorisation Spatz - produktinfo.conrad.com  DKファン - 大建工業  gm-LG QSG Network  Kicker KX100.2 Stereo Amplifier User Manual  取扱説明書 - LIXIL  Philips Feed-thru connectors SWV3033S  