1. 87 44 0 2 3 With Extension Base Unit Q55B Machine screw holes M4 x 2 2 4d locations in N these locations l for conversion LO co adapter anchor am base installation ov i ERNT AQF5 126 6 0 2 K 31 8 0 2 4 With Extension Base Unit Q52B Machine screw o holes M4 x 2 a locations in o these locations a for conversion adapter anchor base installation J RNT AGF3 4 0 2 71 0 2 Use of a base adapter sold separately eliminates the need for additional screw hole machining on the control panel A base adapter is a product that enables MELSEC Q series installation using the MELSEC A series installation holes 7 External Dimensions 7 1 Conversion Adapter Mounting bracket 92 204 257 1 27 4 7 2 Conversion Adapter Anchor Base 20 REA 98 r 1 Model A B C ERNT AQF12 335 8 305 8 321 2 ERNT AQF8 224 6 194 6 210 ERNT AQF5 141 2 111 2 126 6 ERNT AQF3 85 6 55 6 71 Product Warranty Details Please confirm the following product warranty details prior to product use Gratis Warranty Terms and Gratis Warranty Range If any fault or defect hereinafter referred to as Failure attributable to Mitsubishi Electric Engineering Company Limited hereinafter referred to as MEE should o
2. A38B Q312B ERNT AQF12 A38HB Q38B ERNT AQF8 ERNT AQB68 A68B Q612B Q68B ERNT AQB58 A58B Q68B ERNT AQF8 ERNT AQB35 A35B Q38B ERNT AQF8 Q35B ERNT AQF5 ERNT AQB65 A65B Q68B Q65B Q55B ERNT AQB55 Q65B ERNT AQF5 Q55B ERNT AQB32 Q33B ERNT AQF3 ERNT AQB62 Q63B Q52B ERNT AQB52 Q52B 4 Mounting and Installation 4 1 Handling Precautions 1 Do not touch the terminals during energization Doing so could result in electric shock or malfunction Do not disassemble or modify the conversion adapter Doing so could result in failure malfunction injury or fire Do not come in direct contact with the conductive area of the conversion adapter Doing so could result in system malfunction or failure Fully secure the conversion adapter and conversion adapter anchor base using the installation screws and securely tighten the screws within the specified torque range Failure to do so could cause the conversion adapter and anchor base to fall resulting in conversion adapter and conversion adapter anchor base damage 4 2 Use Precautions Item Use Precautions Wiring A wiring change is required if the COM terminals have been separated due to a change in the number of points per common from 8 points 2 circuits to 16 points Module width Because the module width decreases from 37 5mm to 27 4mm the wiring area dimension decreases Verification prior to installation is required M
3. series terminal numbers TB9 18 have been separated due to a change in the number of points per common from 8 points 2 circuits to 16 points 2 For detailed specifications not stated in the Output Module Specification Comparison Chart and for general specifications refer to the user s manual of the output module to be used Those areas with specifications that are different for the MELSEC A series and MELSEC Q series are subject to specification restrictions upon replacement Check the specifications of the connection device 3 Products Required by the Conversion Adapter 1 Conversion Adapter Anchor Base Sold Separately The conversion adapter anchor base secures the bottom of the conversion adapter and is required for conversion adapter use One anchor base is required per base Conversion Adapter Specifications Anchor Base Model Type Weight g ERNT AQF12 12 slot conversion adapter anchor base 590 ERNT AQF8 8 slot conversion adapter anchor base 410 ERNT AQF5 5 slot conversion adapter anchor base 275 ERNT AQF3 3 slot conversion adapter anchor base 185 2 Base Adapter Sold Separately The base adapter enables MELSEC Q series installation using the installation holes of the MELSEC A series base unit Additional hole machining not required Specifications Base Adapter Model MELSEC A Series MELSEC Q Series Installable Conversion Compliant Module Compliant Module Adapter Anchor Base ERNT AQB38
4. 3 is required Q Base Unit Conversion Adapter Anchor Base ERNT AQF12 ERNT AQF8 ERNT AQF5 ERNT AQF3 Applicable O Applicable with some restrictions X Not applicable 1 There are certain slots in which the conversion adapter cannot be installed For example the conversion adapter cannot be installed in Slots 8 to 11 4 slots of the Q base unit when Q132B Q base unit is used with ERNT AQF8 conversion adapter anchor base The machining of screw holes M4 x 2 locations used to install the conversion adapter anchor base such as described below is required when a base adapter sold separately is not used 1 With Main Base Unit Q312B Q38B Q35B or Q33B CPU Machine screw holes M4 x 2 locations these locations for conversion adapter anchor base installation V Conversion 2 I ERNT AQF 7 Adapter Anchor Base 118 5 0 2 ERNT AQF12 94 8 0 2 0 2 ERNT AQF8 ERNT AQF5 ERNT AQF3 2 With Extension Base Unit Q612B Q68B Q65B or Q63B Machine screw holes M4 x 2 locations in these locations for conversion adapter anchor base installation Conversion 4 Adapter udis B Anchor Base ERNT AQF12 ERNT AQF8 ERNT AQF5 ERNT AQF3 __118 5 0 2 FNIT EINE EP PET EE EE YY
5. A Series MELSEC Q Series AY22 QY22 No of input points 16 points 16 points Isolation method Photocoupler isolation Photocoupler isolation Rated load voltage 100 to 240V AC 50 60 2 5 100 to 240V AC 50 20 15 Maximum load voltage 2A point 3 3A common 0 6A point 4 8A common Maximum load voltage current 24V AC 100mA 100V AC 10mA 240V AC 20mA 24V AC 100mA 100V AC 25mA 240V AC 25mA Maximum inrush current 40A 10ms or less 15A 100ms or less 20A 1 cycle or less OFF leakage current 1 5mA 120V AC 60H2 3mA 240V AC 60Hz 1 5mA or less at 120V 60Hz or less at 240V 60Hz Maximum voltage drop at ON 1 5V AC or less 1 to 2A 1 8V AC or less 0 2 to 1A 5V AC or less 0 2A or less 1 5V or less OFF ON 1ms or less 1ms 0 5Hz or less Response time ON gt OFF 0 5 CYCLE 1ms or less 1ms 0 5Hz rated load resistance load Surge killer CR absorber 0 022uF 470Q Varistor 387 to 473V CR absorber Fuse Available None Fuse installation recommended at external wiring Internal current consumption 305mA TYP All points ON 250mA MAX All points ON Wiring method for common 8 points 1 common 16 points 1 common External connection system Note 20 point terminal block 18 point terminal block 1 A wiring change is required if the MELSEC A
6. E opportunity losses or lost profits incurred by the user due to Failures of MEE products damages or secondary damages arising from special circumstances whether foreseen or unforeseen by MEE compensation for accidents compensation for damages to products other than MEE products or compensation for other work carried out by the user Changes in Product Specifications The specifications given in the catalogs manuals and technical documents are subject to change without notice This document is a new publication effective October 2005 Specifications are subject to change without notice The standard price does not include consumption tax Please note that consumption tax will be added at the time of purchase This manual was printed on recycled paper Developed October 2005 50EM8552 A
7. ELSEC A series MELSEC Q series module module 87 5 b The depth increases Verification prior to installation is required Q series module A series module Renewal tool Conversion adapter Base adapter Conversion adapter anchor 166 2 base 36 2mmUP 24 4mm The value in parentheses is the dimension when the base adapter is not used 4 3 Installation Environment For details of the installation environment refer to the user s manual of the CPU module to be used 5 Part Names and Installation Method Q series module A Mounting bracket conversion adapter accessory M3 5 x 6 conversion adapter accessory M3 5 x 6 conversion adapter accessory Conversion adapter installation screw M3 x 30 MELSEC A series terminal block installation screw 2 A b Conversion adapter p Conversion adapter bottom installation screw M3x45 s Conversion adapter anchor base installation screw M4 x 8 conversion adapter anchor base accessory MELSEC A series _ terminal block 5 1 Installation Method 1 2 3 4 5 6 Secure the conversion adapter anchor base to the base adapter or control panel using the conversion a
8. MEE Mitsubishi General Purpose Programmable Logic Controller Renewal Tool Conversion Adapter Model ERNT AQTY22 User s Manual EAN T AQTY22 Model ERNT AQTY22 50 8552 0510 SAFETY PRECAUTIONS Always read these precautions prior to use Before using this product please read this manual carefully and pay full attention to safety to ensure that the product is used correctly The precautions presented in this manual are concerned with this product only For PLC system safety precautions refer to the user s manual of the CPU module to be used In this manual the safety precautions are ranked as DANGER and CAUTION Pd x EI DM a s P A b A pz sopes M I DANG ER Indicates that incorrect handling may cause hazardous I T T I conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous A CAUTION conditions resulting in medium or minor injury and or property i I at Note that failure to observe the A CAUTION level instructions may lead to a serious consequence according to the circumstances Always follow the precautions of both levels because they are important to personal safety Please keep this manual in an easy to access location for future reference and be sure to provide the manual to the end user Installation Precautions N CAUTION Use the conv
9. Series SH 080042 Building Block I O Module By Mitsubishi Electric Corporation 13JL99 Remarks User s Manual 1 Overview This manual describes the Mitsubishi general purpose PLC renewal tool conversion adapter ERNT AQTY22 and the conversion adapter anchor base sold separately ERNT AQF12 AQF8 AQF5 AQF3 that secures the bottom of the conversion adapter The conversion adapter is a product that converts the differences in MELSEC A series and MELSEC Q series pin assignments Once you have opened the packaging verify that it contains the following products Product Quantity Conversion adapter Mounting bracket Mounting bracket fixing screw M3 5 x 6 2 Conversion Adapter Product Specifications No of Connection Points ERNT AQTY22 AY22 16 points QY22 130 Conversion Adapter A Series Model Module Model Q Series Module Conversion Adapter Model Weight g A Series Terminal Terminal Q Series Block Terminal UJ wW e aja UJ mia W A 1 wW a 1 wW o UJ A wW L Ho L HT HE e MH TB10 L HL L L L IL IL 4 18 4 4 Conversion Adapter Output Module Specification Comparison Chart Specifications MELSEC
10. ccur within the gratis warranty period MEE shall repair the product free of charge via the distributor from whom you made your purchase m Gratis Warranty Period The gratis warranty period of this product shall be one 1 year from the date of purchase or delivery to the designated place Note that after manufacture and shipment from MEE the maximum distribution period shall be six 6 months and the gratis warranty period after manufacturing shall be limited to eighteen 18 months In addition the gratis warranty period for repaired products shall not exceed the gratis warranty period established prior to repair m Gratis Warranty Range The gratis warranty range shall be limited to normal use based on the usage conditions methods and environment etc defined by the terms and precautions etc given in the instruction manual user s manual and caution labels on the product Warranty Period after Discontinuation of Production 1 shall offer product repair services fee applied for seven 7 years after production of the product has been discontinued Discontinuation of production shall be reported via distributors 2 Product supply including spare parts is not possible after production has been discontinued Exclusion of Opportunity Loss and Secondary Loss from Warranty Liability Regardless of the gratis warranty period MEE shall not be liable for compensation for damages arising from causes not attributable to ME
11. dapter anchor base installation screws M4 x 8 provided as an accessory Two end locations Secure the mounting bracket to the Q series module using the mounting bracket fixing screws 5 x 6 conversion adapter accessory two upper lower locations Mount the conversion adapter onto the mounting bracket Secure the conversion adapter using the conversion adapter bottom installation screw M3 x 45 1 location Secure the conversion adapter using the conversion adapter installation screws M3 x 30 2 locations Secure the MELSEC A series terminal block to the conversion adapter using the terminal block installation screws M4 two upper lower locations 5 2 Tightening Torque Tighten the module installation screws to the specified torque below An inappropriate tightening torque could cause the product to fall or result in a short circuit product failure or malfunction Screw Location Tightening Torque Range Conversion adapter anchor base installation screw M4 screw 139 to 189N ocm Mounting bracket fixing screw M3 5 screw 68 to 92 Conversion adapter bottom installation screw M3 screw Conversion adapter installation screw M3 screw 43 to 57 MELSEC A series terminal block installation screw M4 screw 102 to 138 6 Conversion Adapter Anchor Base Installation Method To use the conversion adapter a conversion adapter anchor base ERNT AQF12 AQF8 AQF5 AQF
12. ersion adapter and conversion adapter anchor base in an environment of the general specifications defined in the CPU module user s manual Failure to do so could lead to electric shock fire malfunction or product failure or deterioration Do not come in direct contact with the conductive area of the conversion adapter Doing so could lead to system malfunction or failure Fully secure the conversion adapter and conversion adapter anchor base using the installation screws and tighten the installation screws securely within the specified torque range Failure to do so could cause the conversion adapter and anchor base to fall resulting in conversion adapter and conversion adapter anchor base damage Wiring Precautions Be sure to shut off all phases of the external power supply before performing installation or wiring work Failure to do so could result in electric shock or product damage you want to energize and run the unit after completing the installation and wiring work be sure to close the terminal block cover attached to the MELSEC A series terminal block Failure to do so could result in electric shock N CAUTION Properly wire the conversion adapter after verifying the rated voltage and terminal layout of the input output module to be used Connecting a power supply with a different rating or improper wiring could lead to fire or product failure Securely tighten the conversion adapter installation screws conver
13. sion adapter anchor base installation screws and MELSEC A series terminal block installation screws within the specified torque range A loose screw may result in a short circuit fire or malfunction An excessively tightened screw may result in screw or conversion adapter damage causing the conversion adapter to fall a short circuit or product malfunction Do not allow foreign matter such as cuttings or wiring shavings to enter the conversion adapter or module Doing so could lead to fire failure or malfunction Startup and Maintenance Precautions Do not touch the terminals during energization Doing so could result in electric shock or malfunction Be sure to shut off all phases of the external power supply before cleaning and retightening the terminal screws Failure to do so could lead to electric shock Excessively tightened screws could result in conversion adapter or input output module damage causing the conversion adapter to fall a short circuit or product malfunction N CAUTION Do not disassemble or modify the conversion adapter Doing so could lead to failure malfunction injury or fire The conversion adapter case is made of resin Do not drop or apply excessive impact to the case Doing so could lead to conversion adapter damage Disposal Precautions When disposing of the product treat it as industrial waste Related Manuals Manual No Manual Title Model Code MELSEC Q

Download Pdf Manuals

image

Related Search

Related Contents

USER MANUAL - Manfred+Cracco  divx ht6500 H&B  estudio de mercado - Inicio  Wood Burning Inset Stove Installation and Operating Instructions  Nasiff - Medical Equipment Wholesaler  PRISM Single Purchase User Manual - Metropolitan St. Louis Sewer  · Ö Ç ø D : 1. PANTONE BLACK C 2. 3. A5 4. , 5.  AP105-TM11P-66P  British Telecom 075600  Whynter RPD-621EW Use and Care Manual  