Home

AC-3000F - Rice Lake Weighing Systems

image

Contents

1. E ase amp AC 3000F e User s Manual Operator e Rev O page 27 4 2 Voiding the Last Transaction This function cancels the transaction of the previously printed label receipt This function must be used before calling up the next PLU D Void the transaction e Press the VOID key e The previous label receipt issue transaction will be canceled TULIP e The voiding display will be displayed for a few 4 3 Changing from Weighed Item to Fixed price Item This function is used to change the mode from the weighed item to the fixed price item This function must be used when the PLU is displayed on the screen 1 Enter the fixed price Example Fixed price 8 00 Note Skip this step if the fixed price is the same o o as the preset unit price H Press the FIXED PRICE key PRICE 4 4 Fixed Weight Override This function is used to temporarily change a fixed weight of the fixed price item This function must be used when the PLU is displayed on the screen Change the fixed weight Example Current weight 50 oz e Enter the new weight and press the FIXED New weight 63 oz WEIGHT key aa 4 5 Date Override This function is used to temporarily change the current date This function must be used when the PLU is displayed on the screen Note This function is not available when printing in the receipt mode H Enter the date e Enter the date MMDDYY
2. AMOUNT DISCOUNT Used to subtract the entered amount from the selling price PERCENT DISCOUNT Used to subtract the entered percentage from the selling price SAVE Used to save PLU data until the SAVE key is pressed again PRINT Used to print labels Also used to start batch printing FORMAT Used to select the lable format 1 4 BOUQUET Used to add a handling charge for a customized bouquet PRESET AMOUNT DISCOUNT Used to access preset discount amount PRESET CHARGE Used to add by percentage the handling charge PRESET CHARGE AMOUNT Used to add by monetary amount the handling charge page 11 1 4 Loading Label Receipt Roll 1 Make sure that the power is off Open the side cover Pull the release lever to raise the printer head Load the new roll onto the holding shaft Note Before installing the label roll remove labels from the first 30 cm 12 inches of backing paper OFF Thread the paper through positions as shown in the diagram Check that the backing paper is e threaded properly under the guide shaft e threaded properly through the label sensor e threaded properly over the peeling bar making sure it passes through the groove Release Lever Printer Head Label Holding Shaft Label Guide Printer nit e Peeling Bar Label Sensor Guide Shaft When the label needs to be wound up wind the end of the backing paper around the wi
3. operation should be performed after the PLU has been accessed and before the label is issued This function can be used at any time Note This function is not available when printing in the receipt mode Select the desired store name STORE e Enter the store name number and press the 2 NAME STORE NAME key Example Store name no 2 AC 3000F User s Manual Operator Rev O page 29 4 9 Care Extra Text Print With this function a preset care extra text can be selected and printed on the first label This operation should be performed after the PLU has been accessed and before the label is issued This function must be used when the PLU is displayed on the screen Note This function is not available when printing in the receipt mode D I Select the desired care extra text e Enter the care extra text number and press the 1ST CARE TEXT key El Note When extra text printing is not needed o gt press the 0 key followed by the 1ST CARE TEXT key Example Care extra text no 10 4 10 Care Coupon Text Print With this function a preset care coupon text can be selected and printed on the second label This operation should be performed after the PLU has been accessed and before the label is issued This function must be used when the PLU is displayed on the screen Note This function is not available when printing in the receipt mode Select the desired care
4. the cash payment transaction and issue labels AC 3000F User s Manual Operator Rev 0 1 3 3 Additional Function Keys DATE TIME STORE NAME LOGO 2ND CARE TEXT POP TEXT FIXED m D T ao UTM DX m NG 3 4 DATE TIME Used to display the current date and time for a few seconds STORE NAME Used to change the store name corres ponding to the entered number LOGO Used to access a logo message corres ponding to the entered number after the PLU has been accessed 1st CARE EXTRA TEXT Used to print the care instruction on the first the label 2nd CARE COUPON TEXT Used to print the care instruction on the second the label POP TEXT Used to access the POP text corres ponding to the entered number after the PLU has been accessed FIXED WEIGHT Used to temporarily change a fixed weight of the fixed price item FIXED PRICE Used to temporarily change from weight item sales to fixed price item sales Also used to enter a new fixed price Preset Key Examples CHECK Used to finalize check payment transactions CARD Used to finalize credit card payment transactions PRESET PLU Used to access PLU data from among two levels PRESET PERCENT DISCOUNT Used to access preset discount percentage AC 3000F User s Manual Operator e Rev O DISCOUNT SAVE PRINT BOU QUET DIBIO DISCOUNT Used to enter a special selling price
5. DER Been AC 3000F page 34 Error Message IMPROPER POSITION CHECK CASSETTE CHARACTER OVER POP MESSAGE OVER CHARACTER AD MESSAGE OVER CHARACTER REG CODE OVER CHARACTER STORE NAME ADDR OVER CHARACTER LABEL END LABEL SIZE ERROR PRICE DISCOUNT IS TOO LARGE TABLE STRUCTURE CORRUPTION MAX ITEM NUMBER OVERFLOW SAME OPR TOTALING ON MAC AME OPR PROCESSING ON OTHER MEMORY NOT INITIAL SET SYSTEM ERROR E2ROM NOT INITIAL SET NO POWER SCALE REMOVE THE ITEM ON THE PLATTER REMOVE THE ITEM ON THE PLATTER COMM ERROR ON RESULT TRANSFER MASTER CONNECTION ERROR SYSTEM ERROR CHECK CABLE SYSTEM ERROR CHECK MASTER SCALE MASTER IS OFF LINE MEMORY AREA OVERFLOWED ERROR ON COMM CROSSOVER N Error Contents The cassette is not in the correct position AC 3000 only PLU name has too many characters per line Insufficient space for POP message Extra text has too many characters per line Insufficient space for register code Store name and address have too many characters per line All labels have been used Improper label size is used The discounted price is incorrect Table structure has become corrupted Maximum number of items exceeded receipt application only An operator performed sub total operation at a different scale The same operator code is used at a different scale Memory has not been initialized A fundamental system error has occurred E2 ROM has not been initializ
6. ISHIDA AC 3000F Retail Scale Operator Manual ee RICE LAKE WEIGHING SYSTEMS Industrial Solutions on a Global Scale St This manual is based on standard specifications Therefore application of this manual may depend on the country standards or customer specifications You can help to improve this manual by calling attention to errors and by recommending improvements Please convey your comments to the nearest Ishida Company regional representative Thank you Copyright 1997 by Ishida Co Ltd All Rights Reserved No part of this manual may be reproduced in any form by mimeograph or any other means without written permission of the publisher VAN CAUTIONS FOR USE Always operate the scale on a level surface Do not expose the scale to Do not allow any liquids to come direct sunlight for long periods into contact with the scale or terminal Do not drop or apply a strong When cleaning the scale only use shock to the scale a soft dry cloth or a cloth wetted with a neutral cleanser Never use thinner or other volatile liquids Always operate the scale with the same rated AC power supply shown on the specification plate VAN SAFETY CONSIDERATIONS To ensure safe operation the general safety considerations below must be followed Grounding This instrument is a Class 1 device which requires protective grounding for safe operation To avoid potential shock hazards a protect
7. PLU page 10 NUMERIC ENTRY Keys 0 through 9 are used to enter numeric data CLEAR Used to cancel incorrectly entered numeric data Also used to stop printing labels Also used to return to the operation mode LABEL BATCH Used to issue batches of labels LOWER PRESET Used to access the second level of data programmed to the preset keys MULTIPLY Used to multiply the entered quantity of fixed price items PACK COUNT SUB TOTAL Used to issue a label that shows the number of labels packs total weight and amount which have been transacted since this key was last pressed PAPER FEED Used to advance labels receipts to the correct printing position PLU SELECT Used to access PLU data Also used to display the tare weight PRE PACK 4 m VOID 20 m D H SUB g E FE AMT g E L PREPACK Used to switch between auto printing mode and manual printing mode PROGRAM MODE Used to enter the subtraction mode after a d digit password has been entered Also used to exit the subtraction mode TEMPORARY DATE Used to temporarily change the current date VOID Used to cancel the previous item registra tion HELP Used to display an explanation up to 32 letters of each function RESET Used to forcibly exit a particular mode and return to the initial status of the operation mode SUBTOTAL Used to obtain the subtotal for customized bouguets AMOUNT TOTAL Used to finalize
8. and press the DATE key Example November 20 1997 Note The scale may be configured at installation to override the expire date instead of the current ees gt date M Month D Day Y Year page 28 AC 3000F User s Manual Operator Rev 0 4 6 Save The SAVE key is one of the additional function options During a transaction the SAVE key can be used to maintain accessed PLU data that will be used repeatedly This data is reset when the SAVE key is pressed again ER Select the PLU e Select the desired PLU if not already Select PLU displayed Save the PLU e Press the SAVE key Then the SAVE indicator will light Note To cancel the save mode press the SAVE key again 4 7 Logo Print With this function a preset logo can be selected and printed on the labels This operation should be performed after the PLU has been accessed and before the label is issued This function must be used when the PLU is displayed on the screen Note This function is not available when printing in the receipt mode EN Select the desired logo e Enter the logo number and press the LOGO key Note 1 When logo printing is not needed D press the 0 key followed by the LOGO key 2 Label format must be configured to allow logo printing Example Loge ne 2 4 8 Store Name Print With this function a preset store name can be selected and printed on the labels This
9. coupon text e Enter the coupon text number and press the 2ND CARE TEXT key 2ND Note When coupon text printing is not needed 3 o gt press the 0 key followed by the 2ND CARE TEXT key Example Care coupon text no 30 4 11 POP Text Print With this function a preset POP text can be selected and printed on the labels This operation should be performed after the PLU has been accessed and before the label is issued This function must be used when the PLU is displayed on the screen Note This function is not available when printing in the receipt mode EN Select the desired POP text e Enter the POP text number and press the POP TEXT key e Note When POP text printing is not needed 6 2 press the 0 key followed by the POP TEXT key Example POP text no 6 page 30 AC 3000F User s Manual Operator Rev 0 CHAPTER 5 SUBTRACTION Contents 5 1 Subtraction 5 1 Subtraction The subtraction is used to subtract the transacted total from the running totals The operator has to enter the PLU number quantity and price The recommended way to manage subtraction is to keep all incorrectly produced labels in one place and subtract each label in turn Note Confirm that the Operation Key Sheet and not the Program Key Sheet is being used for this operation EN Enter the subtraction mode e Enter the password followed by the PROGRAM MODE key to enter the subtrac ti
10. ed The internal cables are not properly connected An item is on the platter when the power is turned ON An item is on the platter when the power is turned ON Communication error when sending transaction data The master scale is not properly connected System error involving the cable has occurred System error involving the master terminal has occurred The master scale is not on line Too much data is in the memory area The same transaction data is received by the master scale AC 3000F User s Manual Operation Rev 0 6 2 How to Release Error Conditions e f an error occurs for any reason use the CLEAR key to release the error condition e f trouble occurs during operations and you are unable to return to normal operation use the RESET key to re initialize the scale This operation produces the same effect as turning the power off and then restarting 6 3 How to Replace Fuse If the display does not light when the power is on this may indicate a problem with the fuse Use the procedure below to check and replace the fuse 1 Turn off the power and unplug the power cord from AC outlet 2 Use a Philips head screw driver to remove the fuse holder cover located by ON OFF switch 3 Check whether or not the fuse has blown 4 If the fuse has blown replace with the same type of fuse 5 Return and secure the fuse holder cover 6 Plug the power cord into AC outlet and turn on the scale 6 4 Othe
11. g is on the weigh platter e Check that the initial display appears on the screen e Check that the AUTO indicator is not lit Note If the AUTO indicator is lit press the PREPACK key to turn off the indicator KEY IN ITEM No Enter the PLU Entering PLU number e Enter the PLU number and press the PLU key PLU no 450 Fixed price 2 20 Example Pressing PLU preset key e Press the preset key in which the PLU number is set Note When accessing the lower preset PLU number press the LOWER PRESET key prior to pressing the preset key Example When accessing PLU15 PLU15 PLUS5 Example When accessing PLU95 LOWER PLU15 PRESET 2 PLUS5 Multiply the quantity if any e When selling more than one of the same item enter the quantity and press the MULTIPLY key e Otherwise go to the next step Multiple labels e Enter the number of labels and press the PRINT key Note Press the CLEAR key once to temporarily stop printing To continue printing press the PRINT key again One label e Press the PRINT key 4 Issue the label X 3 gt Example Ten labels eis Example One label PRINT AC 3000F e User s Manual Operator e Rev 0 page 17 2 3 Prepack for Fixed price tem DR Ge the prepack mode Check that nothing is on the weigh platter e Check that the initial display appears on the screen e Press the PREPACK key to turn o
12. ive grounding conductor for the instrument must be securely connected to the main grounding provision by qualified service personnel Do not remove covers or enclosures To avoid personal injury and shock do not open or remove any covers or enclosures of the instrument unless specified in the manual Do not perform unspecified maintenance For your personal safety do not perform any maintenance procedures which are not specified in the manual Disconnect power supply before servicing To ensure your personal safety disconnect the power supply before servicing CONTENTS Chapter 1 Overview RE see eie EO EE EE EE EE 2 Ueleg VE 2 1 3 Operation iN EE EE NE OE EE EE NE EE N AE EE A 1 4 Loading Label Receipt Roll iss ERAS AE GEREGEER ARE GEE KG ARE GER GREG e 6 1 5 Pre operation INSpection E 7 E WT en EE 8 Chapter 2 Basic Operation for Label Application 2 1 Label Operation How ee EE EE RR AR EE EE RR RR EE RR RA EE EE RR ek ee EE RR AR ee EE RR eke ae 10 22 Counter Sale of Fixed price tem RE ESE ESE ESE EE SKREE SEER ERGE SEE DES GES EER Ge WEE 11 2 3 Prepack for Fixed price Hem ii EE EE EE RR ee EE ee ee Ek Rek ee Ee Re ee ea EE 12 24 Label Batch PP ei bie ee DE ee Ee Be Ee Ee oe EE Ee Re ED Ee ED Ge 13 2 5 Pack Count Sub tofal ee EE EE ee Ee ee ee ee GEE 14 Chapter 3 Basic Operation for Receipt Application 3 1 Bouquet Operation FIOW csccccccsssseeeeesseeeeeeseaseeeeeseaseeeesseaseeeesseaseeee
13. key Example PLU no 450 Pressing PLU preset key e Press the preset key in which the PLU number is set Note When accessing the lower preset PLU number press the LOWER PRESET key prior to pressing the preset key BATCH MODE ROSE Example When accessing PLU15 PLU15 PLUS5 Example When accessing PLU95 LOWER PLU15 gt EE Enter the desired number of labels e Enter the number of labels to be issued Max 999 e Press the LABEL BATCH key Example Twenty labels 2 Lo WS BATCH MODE ROSE H Enter any other PLUS if necessary e Repeat steps 2 and 3 when labels for any other PLUs are needed A maximum of 20 PLUs can be entered E Print labels e Press the PRINT key Note Press the CLEAR key to temporarily stop printing To continue printing press the PRINT key again To cancel batch press CLEAR key again AC 3000F User s Manual Operator e Rev O page 19 2 5 Pack Count Sub total This function is used to print the pre packing information label including the total quantity total weight and total amount which have been issued since the last time the PACK COUNT key was pressed 1 Enter the pack count sub total mode e Press the PACK COUNT key PACK COUNT PRINT TO PRODUCE SUBTOTAL H Print the pack count sub total e Press the PRINT key e The scale returns to the initial display after issuing pack count sub tota
14. l label page 20 AC 3000F User s Manual Operation Rev O CHAPTER 3 BASIC OPERATION FOR RECEIPT APPLICATION 3 1 oil 3 1 2 3 2 3 3 3 3 1 3 3 2 3 3 3 3 3 4 3 3 5 Contents Bouquet Operation FOW wee 16 en te uge Beete TE 16 OpEIAIIONEIOW EE RE EE ERG ek ee 16 Fixed price ITEM Sale se 17 SUDTOTAI DISCOUNT ee ese ee 18 Subtotal Amount DISCOUNT ees ee 18 Subtotal Percent DISCOUNT un 18 Subtotal Special Price 18 Handling Charge P ee uer Ven ie tte ue ven 19 Handling Charge mount 19 3 1 Bouquet Operation Flow 3 1 1 Start up Operations 1 Label issuing mode e Press the PREPACK key to turn on the AUTO indicator if it is not lit 2 Customized bouquet issuing mode e Check that the AUTO indicator is not lit Note If the AUTO indicator is lit press the PREPACK key to turn off the indicator 3 1 2 Operation Flow page 22 d On Demand Operations Chapter 4 Ae Quantity multiplication Fixed price Item Sale ane e Fixed price change Section 3 3 Item amount discount Item percent discount Item special price e Subtotal amount discount Section 3 5 1 e Subtotal percent discount Section 3 5 2 Finalizing Transaction Issuing Receipts AC 3000F User s Manual Operator Rev O 3 2 Fixed price Item Sale EN Initial display e Check that nothing is on the weigh platter Pd e Check that the initial display appears on
15. n INSpe ction TO ROWS OR ES GE ee ie De 1 1 Appearance Customer Display Power Switch Fuse Height Adjustment Key Sheet 1 2 Operator Display Operator Display Side Cover Se UNTPRICE SAVE AUTO L PLU ISHIDA AC BOOOF J Indicators SAVE Lights when the SAVE mode is used AUTO Lights when the AUTOMATIC PRINT prepack mode is used page 8 AC 3000F User s Manual Operator Rev 0 1 4 Operation Keys 1 3 1 Operation Key Sheet COUPON TEXT Operation Key Sheet Program Key Sheet Insert the Operation Key Sheet over the Program Key Sheet AC 3000F User s Manual Operator e Rev O EI N 2 m ZS SO GE RS Mm U Q CH lt 9 G om SR Tm DE A HI ce DEZ Pou D m z 3x ja rm Q Ee SP E Oo OPE ds Fi e z D hel E Cc Preset Keys Additional Function Keys Six of the following options can be preset by the dealer in accordance with the customer s request e DATE TIME STORE NAME LOGO 1st CARE EXTRA TEXT 2nd CARE COUPON TEXT POP TEXT FIXED PRICE e DISCOUNT e AMOUNT DISCOUNT PERCENTAGE DISCOUNT e SAVE PRINT FIXED WEIGHT FORMAT BOUQUET page 9 1 3 2 Basic Function Keys 0 el CLR jes gt D og I m 36 n D m m 4 D MULTIPLY ir PACK COUN PAPER FEED
16. n the AUTO indicator if it is not lit H Enter the PLU Entering PLU number e Enter the PLU number and press the PLU key PLU no 450 Fixed price 2 20 Example Pressing PLU preset key e Press the preset key in which the PLU number is set Note When accessing the lower preset PLU number press the LOWER PRESET key prior to pressing the preset key Example When accessing PLU15 PLU15 PLUS5 Example When accessing PLU95 LOWER PLU15 PRESET gt PLUS5 H Print labels Continuous issue e Press the PRINT key to continuously issue labels e Press the CLEAR key to stop printing Specified number of labels e Enter the number of labels and press the PRINT key Note Press the CLEAR key once to temporarily stop printing To continue printing press the PRINT key again PRINT ML KLEE Core N 4 ee CLR Example Ten labels aa 2 D Exit the prepack mode e Press the PREPACK key e The AUTO indicator will turn off KEY IN ITEM No men page 18 AC 3000F User s Manual Operator Rev O 2 4 Label Batch Print This function presets the number of fixed price labels max 20 PLUS to be printed This function is only available for fixed price items Er Enter the label batch print mode e Press the LABEL BATCH key to enter the label batch print mode DH Enter the PLU Entering PLU number e Enter the PLU number and press the PLU
17. nding sleeve and secure it with the U pin as shown in the diagram Push the printer head down until it locks securely Close the side cover Turn on the power and press the PAPER FEED key to advance the label receipt to the correct printing position page 12 Release Lever Printer Head Label Holding Shaft Label Guide Printer Unit A Peeling Bar Label Sensor Winding Sleeve Guide Shaft ON PAPER Ges FEED a AC 3000F User s Manual Operator Rev 0 1 6 Pre operation Inspection In order to maintain optimum scale performance perform the following inspection before starting daily operations Always turn off the power switch when performing this inspection CAUTION 1 Make sure that the power is off SS OFF 2 Check that the scale and the level device aperture are clean and free of foreign matter label adhesive etc to make the scale level If not wipe any soiled areas with a dry cloth 3 In order to maintain good printing quality clean the thermal head at least once a week with a cotton swab dipped in cleaning fluid Do not use metal tools to clean the thermal head as they may damage the head surface CAUTION 4 Adjust the scale to level by using the height adjustment feet Level Indicator GIO Correct Incorrect Height Adjustment 5 Make sure the label receipt amount is sufficient AC 3000F User s Manual Opera
18. on mode Example Password 70 00 Note To exit the subtraction mode press the PROGRAM MODE key again e Press the ENTER key ooo SUBTRACTION MODE PRESS ANY KEY ENTER H Enter the PLU e Enter the PLU number followed by the PLU key Example PLU no 2 ENTER PLU NUMBER 3 Enter the quantity e Enter the quantity of the item label to be subtracted and press the VOID key Example Three 3 pcs D Enter the price e Enter the price of the item label to be subtracted and press the VOID key Example 3 75 Note Ifa mistaken entry was made use the VOID key to return to the screen with the mistake Then enter the correct data D Print e Press the PRINT key 000002 PRESS PRINT 0 00 PRINT D Repeat the transaction e Repeat steps 2 through 5 for any other items labels to be subtracted Return to the initial display e Press the PROGRAM MODE key to return to the initial display 1 D KEY IN ITEM No nn mr page 32 AC 3000F User s Manual Operation Rev 0 CHAPTER 6 TROUBLESHOOTING 6 1 6 2 6 3 6 4 Contents Error MESSAGES siene Ee GEE GE oneness 30 How to Release Error Conditions 31 How to Replace FUSE ccr 31 Other Problems es RE ERG EER 31 6 1 Error Messages When errors occur use the error table below to ascertain the cause of the error and to recover normal operations 7 N CHARACTER OVER
19. r Problems e Poor printing quality The thermal head has become soiled Use the supplied cleaner set to clean the printer head e Labels are not printed as soon as an item is placed on the weigh platter The scale is set in the MANUAL mode AUTO indicator is not lit Press the PREPACK key to turn on the AUTO indicator e Labels are not issued The printing position may not be properly set Press the PAPER FEED key to align the paper to the correct printing position AC 3000F User s Manual Operator Rev O page 35 Y ISHIDA A ISHIDA CO LTD 44 SANNO CHO SHOGOIN SAKYO KU KYOTO 606 JAPAN PHONE 075 771 4141 FACSIMILE 075 751 1634 TELEX 05422065 SCALES J IW702
20. rcent DIGOU se GR Ee GE ELE EG Sp cial PHOS RR EE siden EES ER SEER ENE aes Voiding the Last Transaction Changing from Weighed Item TO Fixed price ITEM ee Fixed Weight Override wn ee Date Override ie ek Beieleit AR E T TT store Name PINE aas sesse EER EER Care Extra Text PINE Care Coupon Text Pint POP E AE EE 4 1 Mark Down Functions The following three mark down options are available Only one of these three options may be used at one time This function must be used when the PLU is displayed on the screen Note The discounted amount or entered special price must be less than displayed total price 4 1 1 Amount Discount EN Enter the discount amount Entering discount amount e Enter the amount to be discounted and press the AMOUNT DISCOUNT key Pressing AMOUNT DISCOUNT preset key e Press the preset key in which the discount amount is set 4 1 2 Percent Discount Example Discount amount 0 50 se EN Enter the discount percentage Entering discount percentage e Enter the percentage 1 99 to be discounted and press the PERCENTAGE DISCOUNT key Pressing PERCENT DISCOUNT preset key e Press the preset key in which the percent discount data is set Example Discount percentage 10 gion 4 1 3 Special Price m Enter the special price e Enter the special price and press the DISCOUNT key Example Special price 4 50
21. rform discount operation e Enter the discount amount and press the AMOUNT DISCOUNT key BORA Iw LI Ir to 3 3 2 Subtotal Percent Discount H Obtain the subtotal amount e Press the SUBTOTAL and BOUQUET keys UDF E e ar H Perform discount operation e Enter the discount percentage and press the PERCENT DISCOUNT key Example Discount rate 5 3 3 3 Subtotal Special Price 1 Obtain the subtotal amount e Press the SUBTOTAL and BOUQUET keys mor l LL I H Perform special price operation e Enter the special price and press the DISCOUNT key Example Special price 10 50 Gole gt BR C ml ut Ir te page 24 AC 3000F User s Manual Operator Rev O 3 3 4 Handling Charge DN Obtain the subtotal amount e Press the SUBTOTAL and BOUQUET keys E Add the handling charge Example Charge 10 e Press the PRESET CHARGE Key 3 3 5 Handling Charge Amount Obtain the subtotal amount e Press the SUBTOTAL and BOUQUET keys 2 Add the handling charge e Press the PRESET CHARGE AMOUNT Key AC 3000F e User s Manual Operator e Rev O page 25 CHAPTER d ON DEMAND OPERATION 4 1 4 1 1 4 1 2 4 1 3 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 10 4 11 Contents Mark DOWN FUNCHONS ee se AMOUNT DISCOUP EE EE SE EER GE HEKS EEN GE Pe
22. ssaaseeeeses 16 3 2 Fixed price ltem Sale ike RR Re EE RE Re GE GN ae Ee AR AE Ge Ak ee ee ke ie Ee 17 3 3 Subtotal DISCOUM 226 RE ER EN AE ee KEN EE N EER EE DE He Ee eile SE be Re DES Se Ee 18 Chapter 4 On demand Operation 4 1 Mark Down Fun e CS 22 4 2 Voiding the Last Transaction E 23 4 3 Changing from Weighed Item to Fixed price Hem ee 23 4 4 Fixed Weight Overrde ekkkkKKKKKKKKRRREREREEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEN 23 4 5 Dale Override ii Rd EE ii Ge Re EE Ee 23 AO OV RE EE EE EE N 24 A7 Joen Print sasies ius as Ge Ak ea Ge ak EG GR Ge rp 24 48 Stor Name di ES OE EE 24 49 Care Extra Text Prins esse ge Re Ee GREG REG ee eg Ge ed ed 25 4 10 C r COUPON Text PIT ii ES RR RR Ge ENG OR Ge RR ee Og ee 25 d d1 POP d PD EE 25 Chapter 5 Subtraction 5 1 SUDHACHON ARE EE Ed EE GE EE OE rrr EE EE nna 28 Chapter 6 Troubleshooting GL Se d ie ie EE EE OE EE EE EE EN 30 6 2 How to Release Error Conditions ees ee RE AR EE EE RR AR ee EE RR RR ee EE RR ek ea EE 31 6 3 How ie Repldce FUSS ies REG KEES ERG ENE EED EE AE EED SEER AGE N SEG EE ED GR 31 6 4 Other Problems SERE aseene EERSTEN 31 CHAPTER OVERVIEW Contents ld Appearance iss ER PIE ES EES 1 2 Operator DisplAy 1 3 Operation KEYS ee 1 3 1 Operation Key Sheet 1 8 2 Basie EUNSION KEYSER EK EERS ENE ii 1 3 3 Additional Function Keys 1 3 4 Preset Key Examples 1 4 Loading Label Receipt Roll 1 5 Pre operatio
23. the screen KEY IN ITEM No e Check that the AUTO indicator is not lit EEEE Note If the AUTO indicator is lit press the Sie PREPACK key to turn off the indicator D Enter the PLU Entering PLU number e Enter the PLU number and press the PLU key Example PLU no 450 Fixed price 2 20 e Press the BOUQUET key to register an item Pressing PLU preset key e Press the preset key in which the PLU number i PLUIS BOU is set l l gt Era e Press the BOUQUET key to register an item E Multiply the quantity if any x BOU 3 gt hi gt e When selling more than one of the same item enter the quantity and press the MULTIPLY key and then press the BOUQUET key to register the multiple items e Otherwise go to the next step Example When accessing PLU15 4 Repeat the item sale if any e Repeat steps 2 and 3 for any other items Example PLU no 480 Fixed price 0 98 5 Issue the receipt Example The customer pays 10 00 e Enter the amount tendered by the customer ANT and press the AMOUNT TOTAL key Then the l 1 if H J H o gt change due will be calculated and the receipt will be issued AMOUNT PCSO2 CHANGE 2 42 AC 3000F e User s Manual Operator e Rev 0 page 23 3 3 Subtotal Discount 3 3 1 Subtotal Amount Discount EJ Obtain the subtotal amount e Press the SUBTOTAL and BOUQUET keys wore aan ar mg B n LL OU I LI Pe
24. tor e Rev O page 13 1 6 Power On Ed Plug in AC power cord e Make sure that the power cord is pluged into the AC outlet E Turn on the power switch H Initial display e Make sure that nothing is on the weigh platter and that the initial display appears Initial display page 14 AC 3000F User s Manual Operation Rev O CHAPTER 2 BASIC OPERATION FOR LABEL APPLICATION 2 1 2 1 1 2 1 2 2 2 2 3 2 4 2 5 Contents Label Operation FIOW ee 10 Stari up OperafioNs EE SEER SE EE gade 10 Operation FIO W iS ee Ed eg a 10 Counter Sale of Fixed price ltem 11 Prepack for Fixed price tem 12 Label Batch Bim 13 Pack Count Sub Totol ee se 14 2 1 Label Operation Flow 2 1 1 Start up Operations 1 Label issuing mode e When automatic printing is desired press the PREPACK key to turn on the AUTO indicator if it is not lit 2 Receipt issuing mode e Check that the AUTO indicator is not lit Note If the AUTO indicator is lit press the PREPACK key to turn off the indicator 2 1 2 Operation Flow Counter Sale Fixed Price Item Section 2 2 Fixed Price Item Section 2 3 On demand Operations Chapter 4 Label Issue On demand Operations Chapter 4 Label Issue page 16 AC 3000F User s Manual Operator Rev 0 2 2 Counter Sale of Fixed price tem H initial display e Check that nothin

Download Pdf Manuals

image

Related Search

Related Contents

König CMP-WNROUT41 ADSL Wi-Fi Ethernet LAN White router  ISANDE  取扱説明書 (1.08 MB/PDF)  DF1 PROTOCOLE 35012365_02.book  ダウンロード - むらき小児科  Abrir y cerrar fondos  THE RICHNESS OF OCCUPATIONAL INSTRUCTION  Torker Bicycle CX User's Manual  Other Applications Troubleshooting Precautions  Gainward 426018336-2760 NVIDIA GeForce GTX 660 2GB graphics card  

Copyright © All rights reserved.
Failed to retrieve file