Home

意万仕 UL-TP100胶灯说明书(GS认证) - Emaux Water Technology

image

Contents

1. aE VA WARNING Never operate this pool lamp for more than 10 seconds unless it is totally submerged in water Without total submersion the lamp assembly will get extremely hot which may result in serious F MAU X injury to pool users installers or bystanders or in damage to property Be sure power is off before installing or removing lamp Allow lamp to cool before relamping w o oO This light fixture uses a Halogen Quartz lamp Do Not touch lamp with bare hand this may La A Water Technology severely reduce its life Use the plastic furnished with the replacement lamp to eliminate finger prints pin from the bulb For use only when immersed in water IP68 For operation only with approved safety isolating transformer Input 230V Output 12V 7 7 75VA UL TP100 Series Underwater Light The safety isolating transformer must meet the EN61558 2 6 standard J SELV eon ae shall be installed outside of Zone 0 1 and 2 O pe rati n g P roced u res Ifyou want to replacement the lamp loosen the screw of back cover open the back cover and replace the lamp and carefully fixed gasket seal re tightening the screw The replacement takes place from the side of the luminaires in contact with the water but after the water of the pool has been partially or completely drained CAUTION Never try to repair or replace the lamp by yourself If this underwater light fixture is out of working it shall be repaired or replaced by the manufacturer or his s
2. OR CONCRETE POOL w w LOCK POSITION OPEN POSITION A G 1 2 V t ern inal 1 am p ri Figure 4 d The light fixture and all metal parts that are within 350cm of the pool must be properly protected with non ductile materials and that the connections must be waterproof FOR EURO LESS POOL e The mounting bracket must be properly installed so that the top edge of the Underwater Light lens is at least Do ge 45CM below the surface of the water in the pool see Figure 1 2 Consult the local Government Building Department to be certain that the pool s electrical system meets all applicable requirements Figure 5 wC DD POSITION POSITION
3. ervice agent or similarly qualified persons in order to avoid a hazard CAUTION The transparent plastic Protective Shield can not be replaced if the Protective Shield is cracked this underwater light fixture shall be scrapped REPLACEMENT PARTS Description Part No Colored Lens Cover 01221003 Face Plate 01051057 Clear Lens 01041020 O ring Seal 02021008 PLEASE READ THE FOLLOWING CAREFULLY AND Sema Na aie KEEP THIS USER MANUAL SAVE FOR FUTURE REFERENCE Globe Holder 04011031 Reflector 03018015 a Cover Over 01231002 Body 01231003 DANGER Screw 03011007 02021024 RISK OF ELECTRICAL SHOCK OR ELECTROCUTION Tooth Head 01231004 Light Bracket 01012005 Screw 03011012 i j Light Bracket 01012006 serviceman in accordance to the requirements of your government standard or local authorities Improper Wall Bracket 01012008 installation will create electric hazards which could result in serious injury death as well as damage to the Light Bracket 01012007 O ring 02011051 FOR FIBREGLASS POOL PRE FAB Nut 01012009 MODULAR POOL AND VINYL LINER POOL This underwater light fixture must be installed by a licensed or certified electrician or a qualified property Before servicing the light disconnect the power supply from the circuit breaker Failure to do so could result in serious injury death and or damage to the property EMLIO9102802 INSTALLATION B Perfor
4. he light for more than 10 seconds fill pool until the Underwater Light is completely submerged in water 12 The flexible cable of this luminaire cannot be replaced if the cord is damaged the luminaire shall be destroyed C Winterizing The luminaire should be left in place for winterization DO NOT MOUNT ON DO MOUNT ON CONCRETE MUST BE CUT BACK AROUND NICHE TO ALLOW FOR A COMPACT PLASTER SEAL W A ie Figure 1 AM a FOR FIBREGLASS POOL PRE FAB MODULAR POOL AND VINYL LINER POOL NA WT REVERSE RADIUS IRREGULAR OR FLAT WALLS WITH NO TIGHTER SURFACE UNEVEN SURFACES SURFACE THAN 6 FT RADIUS AS VIEWED FROM TOP l Ensure that the electrical system and its wiring for the pool conform to the requirements of your govenment or your local authorities The installation of the Underwater Light should only be performed by a licensed Figure 2 Figure 3 electrician i The junction box or the low voltage transformer for 12 volt Underwater Light model is to be located at least 350cm from the edge of the pool see Figure 1 S b The junction boxes shall not be installed in zones 0 1 and 2 where permitted for SELV circuits Terminal blocks must meet the IEC60988 2 1 standard having the rated connecting capacity of 1 5mm2 use SS of screw type terminal at least 25A rated current mounted on junction boxes inside See Figure 0 _ gt screv type A F
5. m the following steps after the electrical system requirements are met 1 Locate position on a vertical wall where light is to be installed The top of the light lens must be 45cm A Preparatory steps which must be completed by the electrician before light below is installed see Figure 1 normal water level and maximum depth for luminaire is 2 5m see Figure 1 SEOGWININ 2 Connect conduit to midst of Mounting Spacer left of Bracket see Figure 2 TO POWER SOURCE l 3 If pool surface is to be plastered you must allow proper concrete cutback for plaster thickness Finish FEED PARAFFIN concrete surface must be flush with Mounting Spacer CAUTION Finish area surrounding Mounting Spacer MUST be flat and flush with the face of Mounting Spacer this ensures a snug fit between light and wall see Figure 3 _WATER LEVEL 4 After pool surface is finished trim the Conduit 5 Wrap a length of the cord up to a maximum of 3 5mt long on the back of the light assembly 6 Connect cord electrical wires at Junction box through Conduit be careful not to pull the 75mm 80mm of eee ee ae slack cord at the light through the conduit when connecting the wires 7 Connect all wires to the corresponding circuit wires in the junction box and feed paraffin 8 Secure the junction box cover in place 9 To check for proper operation turn on main switch or circuit breaker 10 Rotating Locking System ensures light is secured to bracket see Figure 4 11 Before operating t

Download Pdf Manuals

image

Related Search

Related Contents

Clique aqui para baixar o arquivo PDF  BC8-3252/BC10  Instructions PRESS GW1G2G3G4G  Journal - Euroméditerranée  Specifications Genius ColorPage  aSERIES A13VD VariFocal Dome Camera  A “Hands-on” Introduction to OpenMP*  ACHROMATIC MONAURAL POWER AMPLIFIER  Manual de instalação  ComLynx Manuale dell`Utente  