1. Version Date Description V1 0 2005 9 27 Created V1 1 2005 12 2 Incorporated the changes made by BioAdmin V1 1 Chapter 12 Site Key is added V2 0 2006 4 17 Incorporated the changes made by BioAdmin V2 0 Chapter 8 Access Control is added Chapter 9 Monitoring is added V3 0 2006 8 23 Time Attendance added BioStation added V4 0 2007 3 5 Incorporated the changes made by BioAdmin V4 0 V4 1 2007 5 30 Incorporated the changes made by BioAdmin V4 1 V4 2 2007 10 19 Incorporated the changes made by BioAdmin V4 2 BioEntry Plus added Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 15 1 1 1 2 1 2 1 1 2 2 Getting Started Outline This manual illustrates how to use BioAdmin software BioAdmin is a PC Windows software for the control and management of Suprema s BioEntry BioStation and BEACon products BioAdmin includes various functions needed for a host station for applications of access control and time amp attendance using these devices For proper hardware connection please refer to BioEntry Installation manual and BioStation Installation manual There are two approaches in managing BioEntry and BioStation Using BioAdmin program which is the management software running on Windows based PC platforms This manual is mainly focused on operating BioEntry and BioStation using BioAdmin software Integrating the management functio
2. Firmware Version 1 0_071009 192 Device Configuration Operation Mode Network Setting Entrance limit Setting Door Setting 1 0 Setting Command Card Wiegand BioEntry Plus Time Date 18 2007 Time 6 49 40 PM Basic Setting Operation Mode Setting All Always Card Fingerprint No Time Only Card No Time Fingerprint No Time Fingerprint Setting Security Level Normal Scan Timeout 10 Syne with Host PC Time Get Time l Set Time Double Verification Mode Double Verification Mode Double Verification Mode Double Verification Mode 1 N Fast Mode Matching Timeout Refresh son Applyto Others Setto Defautt BioEntry Plus Time Date 1712007 a Time 3 04 25 PM C Syne with Host PC Time Date amp Time Read from BioEntry Plus device Get Time button makes BioAdmin read from BioEntry Plus Copyright 2007 by Suprema Inc Suprema Inc http www supremainc com BioAdmin User Manual 193 There are two methods to read a date amp time shown as below Manual Type Just type date amp time manually and pressing Set Time button makes them transfer to BioEntry Plus device Synchronize with Host PC Time Check it and press Set Time button to transfer to BioEntry Plus device Operation Mode Setting Operation Mode Setting
3. Suprema Inc The details setting of door that is operated by each device may be set up Two doors may be controlled by one device and Secure I O door connected by RS485 may be also controlled Outside Inside Device Set two devices to control 1 door Door Open Relay Set the output terminal to control door among the connected devices Door Open Period sec Set the time when the selected output terminal operates in door open relay Exit Button Select a button input terminal used to open door Door Status Select an input terminal to connect a sensor used to check the status of door Switch Type N O or N C Door Open Alarm sec Enter the time to determine whether door is open for a long time Driven By Select an event when door is open for a time longer than the set Door Open Alarm setting http www supremainc com BioAdmin User Manual 184 Lock Time Set the time when a designated door is always closed as an item inter working with the entrance exit time set in entrance control item Unlock Time Set the time when a designated door is always opened as an item inter working with the entrance exit time set in entrance control item Anti passback Set whether to apply anti passback between Outside and Inside device a Soft Make a record and allow entrance in case of not verifying APB Hard Not allow record and entrance in case of not verifying APB Reset Time Make cleari
4. Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 246 Monitoring BioAdmin supports real time monitoring functions By selecting the Monitoring menu you can check the log events of networked BioEntry and BioStation on time BioAdmin Software 3 System User Management Device Management Access Control Monitoring Event List Task Event Door i Setup Monitoring Date Time Device Event T amp A Event Ce Start Monitoring 2007 10 17 15 43 05 1058 Identify Fail Pause Monitoring 2007 10 16 23 42 55 2686 Identify Success User ID User Name D 853 Dongsuk Suh 2686 Door 0 Relay Or 0 Status Monitoring On 2007 10 17 15 40 07 entify Success Checked Users 1 Total Users 1 Wa Suprema Inc 7 1 Setup Monitoring Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 247 7 2 Monitoring Event Setup Event List Event Real Time Monitoring Reset Sys Function Yes Forced Open Door Yes Held Open Door Yes Door Closed Yes Tamper 1 Yes Tamper 2 Yes Tamper 3 Yes Request to Exit Door 1 Yes Request to Exit Door 2 Yes Clear Alarm 1 Yes Clear Alarm 2 Yes Clear Alarm 3 Yes Enroll Bad Finger Yes Enroll Success Yes Enroll Fail Yes Fingerprint Scan Fail Yes Verify Success Yes Verify Fail Yes BEE ee ee On this menu you can select the events to be shown on the monitoring window simply by double clicki
5. Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 217 Delete Fail Command Card Fail Waiting Smart Card Input Fast blinking red fixed None 4 8 5 Wiegand Setting The Wiegand Setting tab is used to manage the Wiegand input output format of BioEntry By selecting the menu the Wiegand setting page is updated on the main window System Setting UO Setting LED Beep Wiegand Setting Card Configuration Wiegand Format Format 26 bit Standard Change format Load from File Save to File EAAA AAAA AIII IIII IIII IIII I0 Total Bits 26 ID Bits 16 ID bit O ParityBit Odd E ParityBit Even AB Fields Fail ID Disable FC Code Disable Inverse Parity on Fail Disable i Field Default Values Pulse Pulse Width 50 usec Pulse Interval 2000 usec ABA Track Il ABA Track Il Format Disable Apply Apply to Others Set to Default Wiegand Format New Wiegand format can be configured graphically using the Wiegand Configuration wizard The Wiegand Configuration wizard will be shown by pressing the Change format button Select format You should select one of the three supported formats in the first page If Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 218 BioEntry device is connected to the controller by ABA Track II output not by Wiegand interface you should check Use AB
6. All Always kl Double Verification Mode Card Fingerprint No Time v C Double Verification Mode Only Card No Time v C Double Verification Mode Fingerprint Mo Time v C Double verification Mode BioEntry Plus has 4 operation mode setting options from No 1 to No 4 each option may be assigned for its time Double Verification Mode Door is operated as long as different user verifications should be executed within 15 seconds Note Double Verification mode is specially designed for two user s verification for secure access control Fingerprint Setting Fingerprint Setting Security Level Normal v 1 N Fast Mode Auto l Scan Timeout 10 Matching Timeout D v Security Level Normal Secure More Secure Control FAR False Acceptance Rate internally The more FAR the less FRR False Rejection Rate so default is normal level 1 N Fast Mode Auto Normal Fast Faster In case more than hundreds fingerprints are saved in device 1 N mode may take Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 194 longer If you set fast mode as fast or fastest performance is somewhat low but 1 N recognition can take less time Default is normal Scan Timeout 1 20 sec User can designate the standby time when entering fingerprint If a user doesn t enter fingerprint within this time it is construed as input failure Default is 10 sec
7. Auto Mode Schedule is highlighted Please refer to 6 1 Time Zone Setting for definded Time Zone 4 5 5 Device Setting Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 172 This window is to check and change various settings of BioStation EC BioAdmin Software System User Management Device Management Access Control Device Configuration Fe Device Management Task W Search Device Add New BEACon F Remove Device W Check Status Q Refresh Device List Device Info Device Name 5238 New BioStation Device ID Device Type BioStation BSR OC Image amp Sound Operation Mode Notice Wiegand Network Setting Door Setting Firmware Version Function Key J 5238 V1 4_071008 V03 I O Setting Entrance limit Setting Device Setting Fingerprint E All Devices g BioAdmin Server 192 168 1 87 ZE 1058 New BioEntry Plus a F com E 5238 New Biostation Security Level Image Quality Normal Sensitivity TMa 1 N Delay Chk Duplicate FP Disable Input Output Input 0 Disabled Output 0 Tamper Switch None Fingerprint Relay Driven By Lock Time None a 2 sec Disabled All Events Fast Mode v view Image v Scan Timeout v Matching Ki Input 1 Output 1 Duration rns Duration sec Interphone auto Disabled Disabled 1000 3 Di
8. Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual BioAdmin Software 99 4 System User Management Device Management Access Control Device Management Task g Search Device GB Add New BEACon W Remove Device Check Status E Refresh Device List YB BioAdmin Server 1058 New BioEntry Plus 2686 New BioStation SF 192 168 1 254 BB New BEACon 42965 New BioEntry 42714 New BioEntry Device Configuration fe Device Info Device Type Serial Number Device Name Firmware Version System Setting I O Setting LED Beep Wiegand Setting Card Configuration Suprema Inc Select Search Device menu click Search BioEntry select either serial port or TCP PI and then press search button If device is found as a result of search result report reading device s found is shown Press OK button to select device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 100 Add New Device Search BioEntry Search BioStation Serial Port COM Port COM v Baudrate 115200 TCP IP IP Addr Search Searching COM1 Detected Device New BioEntry 1050 Finish Device Search 1 device s found f the devices are connected properly new device ID appears on the Device Tree window Device Tree Ku All Devices a COMI 1050 New BioEntry Select User Managemen
9. Wiegand Card ID Setup Device Default v BioEnty Smart Pass _ 1st Template 2nd Template Device Default v Smart Card AF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Scan Incase of stand alone mode without USB scanner check Use BioStation as Enroll Station press scan button place a finger twice on device and then input the first fingerprint information In case that device is configured by 2 or more networks specify BioStation ID press scan button place a finger on device twice and then input the first fingerprint information Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule 67 Use Device as Enroll Station Device ID 2686 New BioStaton v Wiegand Card ID Setup 1st Template 2nd Template C Duress Duress NV H a ff eS ravers RN Bad PERRE et a a a ae PA E 8 D n an n Dn Dn in SSH n Dina D WAN ae Sara ff of e NN 9 ER NS li td SSN ON e ep Liebe e Dr Dr D D sc en A ag RE SE A Ate a ae LEE OL eA dence al al er ff AA E or 1 1 Security Level BioStation BioEntry Plus Device Default BioEntry Smart Pass Device Defaut v Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Ca
10. Detailed operations are as follows You can set up a Time Zone by combining time codes and a holiday group One time code is selected for each day from Monday to Sunday http www supremainc com BioAdmin User Manual 241 Press Access time setting button Enter the name of access time Access Time Setting Name Schedule 0 6 12 18 24 Sunday New Time Code 4 I 0 6 12 18 24 Monday New Time Code ll Tuesday New Time Code 2 Wednesday New Time Code 3 Thursday New Time Code 3 en 6 12 18 24 Friday New Time Code 4 I 6 12 18 24 D Saturday New Time Code I I TII Holiday Schedule Holiday Group1 New Holiday List v 12 18 Holiday Group2 Disable wl 0 12 Select time span per day of the week from Monday to Sunday Select holiday group Select the time span to apply for holiday group Holiday group may be set in two ways To add the set access time to list of access time click OK button 6 4 Door Zone setting From BioAdmin v4 2 new type of Access Control is used Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 242 V4 1 below Please use previous format New User Please use v4 2 only format If previous user having BioAdmin v4 1 below it is possible to convert to v4 2 only format but won t back to previous format any more Please pay attention to you
11. Device Type BioEntry Plus 1058 New BioEntry Plus 198 If Device ID me sid Firmware Version 1 0_071009 EE Operation Mode Network Setting Entrance limit Setting Door Setting UO Setting Command Card Wiegand Door Mode O No Door Door 0 Name Door 0 Outside Device 1058 Inside Device NotUse Door Relay s100 relay0 Door Open Period sec Exit Button Switch Type Door Status Switch Type Door Open Alarm sec Lock Time None UnlockTime Hong Anti passback APB Type 3 NiO 100 door open buttor v v 100 door open status NiO 10 v O Two Door Mode Outside Device Inside Device Door Relay Door Open Periad sec Exit Button Switch Type Door Status Switch Type Door Open Alarm sec Lock Time Unlock Time Reset Time Minute Refresh l Apply to Others Setto Default W Suprema Inc Outside Inside Device Set two devices to control 1 door Door Relay Set the output terminal to control door among the connected devices Set the time when the selected output terminal Copyright 2007 by Suprema Inc Door Open Period sec operates in door open relay Exit Button Select a button input terminal used to open entrance door which is Input O for use N O Normal Open N C Normal Close Door Status Select an input terminal to connect a sensor used to check the status of entrance door N O or N C which is Input 1 fo
12. Start Date 17 1 71970 Entrance Limitation BioStation Expiry Date 12 31 2030 e h Daily Limit 0 00 23 59 Timed APB Minute Other Information Password BST Admin Leve Normal User j Cancel Especially you can select the Company Department and Title on the drag down menu To add new Company Department or Title information press L button After entering the required information press Add button Press Save button to save the added information Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 91 Company Name Your Company Suprema In addition to the basic user information you can add Custom Fields to the user information If you do not need these custom fields just skip the custom fields setting To set up the custom fields press Custom Fields tab User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Customize Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Click the Customize button 92 Check on the required Fields and enter the user information for those selected fields Custom Fields Text Fields Vv Text 1 Text 2 Text 3 Text 4 Number Fields V Number 1 C Number 2 Date Fields V Date 1 C Date 2 Checkboxes Checkbox 1 M
13. 3 User Management User management covers the following operations Add new user Delete checked user Transfer checked user to device Delete checked user from device Manage users in device Synchronize all users Export to file Upload from file 3 1 Configuration of user management page 113 By selecting User Management menu user management page is updated on the main window Task Box User List B BioAdmin Software System Liser Management Device Management Actess Control User Management User Management Task ompany ES Add New User 3 30 Suprema ES Delete Checked Users Nakwon Lee Suprema Sy Transfer checked users to device ChangGyun Lee Suprema E Delete Checked Users from Device E E Suprema EC Manage Users in Device iganbole Jeon Suprema QA Synchronize All Users Game ahs SE Export to File f Fil IIhwan Gang Suprema amp operon EM Gyunghun Hong Suprema Jonguk Hwang Suprema SE o EES Sg Ce Department Template N Act Manager 3 Manager Engineer Manager Chiet Engineer lt lt lt lt lt lt lt lt lt E Manager Checked Usq rs 1 Total Users 10 Selection tool box Copyright 2007 by Suprema Inc Wa Suprema Inc http www supremainc com BioAdmin User Manual 114 3 2 3 3 The user management page is divided into 3 sectors User List The user database is under central management on host PC The user management page incl
14. Press the Group by this field button and Group by box button to manage the user list as a group by your required columns Also you can add a column to the group simply by dragging up the column to the header box Management Access Control User Management Gi Department e User ID UserName Company Departm Template N Active S Department M amp S 934 ChangGyun Lee Suprema M amp S Manager 1205 Gunsaeng Shin M amp S Manager 3786 Hyunbok Jeon Suprema M amp S Chief 4465 Bohyun Gha Suprema M amp S 4583 Gyunghun Hong Suprema M amp S O0000 Department R amp D a 853 Dongsuk Suh Suprema Manager H Y g 861 Nakwon Lee Suprema R amp D 2 Y gJ 1144 Hoyoung Gyou Suprema R amp D Engineer 2 Y g 4582 llhwan Gang Suprema R amp D Engineer 2 NV g 4584 Jonguk Hwang Suprema R amp D Manager 2 Press the Remove Column button to remove a column from the header Also you can remove a column simply by dragging down the column from the column header Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 117 User Management El Department User ID User Name Company Departm Template N Active B Department M amp S oO 934 ChangGyun Lee Suprema M amp S Manager H Y g 1205 Gunsaeng Shin M amp S Manager 2 a tian Press the Alignment button to array the content in your preferred way Press the Best Fit button to optimize the width of a co
15. RB ees eee Bi fe I Ar AF oe ee Set ZZ d d Ae eieiei eieiei ee d Leger N A A vat Li SOE od SEPALS GES OLE L EE E o LE EE e teg af eer e eier e ee E LAARA de H e Hid fe fe 1 1 Security Level BioStation BioEntry Plus Device Default v BioEntry Smart Pass Device Default v Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Verification Test 95 Press the OK button to complete the registration process Then you can see the information of the registered user on the user list window It means that user s information is added to the database on host PC User Management User ID User Name Company Department Title Template Num Active Dongsuk Suh Suprema R amp D Manager 2 3 3 Step 3 Issuing user smart card Double click the registered user on the user list Then the user information window appears showing the registered information of the user Click Fingerprint tab on user information window Place a smart card on PC USB smart card device and press Write button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 96 Smart Card RF ID S N 0 UselD 853 RF ID 0 C Bypass Card Read Card At first trial site key management window appears If the key input remains blank factory default key is used So just press OK button to comp
16. Search Device Ki Add New BEACon T F Renove Deves on rm mussten mme YW Check Status Refresh Device List Operation Mode Network Setting Function Key Device Setting EE Image amp Sound Notice Wiegand Door Setting UO Setting Entrance limit Setting Device Name 6238 New BioStation Device ID 5238 letwork Notice e All Devices Notification BioAdmin Server EI 192 168 1 87 1058 New BioEntry Plus a E com D 5238 New Biostation Total Length 1024 Byte Current Length p5 Access Control EIER Appiytoothers Ges Suprema Inc 4 5 8 Wiegand The Wiegand Setting tab is used to manage the Wiegand input output format of BioStation By selecting the menu the Wiegand setting page is updated on the main window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Copyright 2007 by Suprema Inc 178 BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info i Search Device Device Name 5238 New BioStation Device ID 5238 ES Add New BEACon BH Remove Device Device Type BioStation BSR OC Firmware Version V1 4_071008 v03 YQ Check Status Refresh Devies List Operation Mode Network Setting Function Key Device Setting We GC Image amp Sound Notice Wiegand Door Setting UO Setting Entrance limit Setting Wiegand
17. Text 1 Hobby Text 2 Fax iren Ip Addr Text 4 Number Fields V Number 1 C Number 3 C Number 2 CI Number 4 Date Fields V Date 1 A Memorial Day C Date 2 Checkboxes Checkbox 1 Married C Checkbox 3 W Checkbox Car C Checkbox 4 After filling out the custom fields following the pop up window will appear On this window you can see the detail of your selected custom fields Press the OK button to save these custom fields Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 106 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Hobby Fax Ip Addr Room No A Memorial Day 4 13 2006 C Married F Car After entering the user information press the Fingerprint tab to enroll user s fingerprint templates Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 107 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 1 1 Security Level BioStation BioEntry Plus Device ID 2686 New BioStation Wiegand Card ID Setup Device Default v BioEnty Smart Pass a 1st Template 2nd Template Device Default v Duress Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Re
18. The width of pulse The default is 50 us Pulse Interval The interval of pulse The default is 2000us Fail ID Normally the module outputs Wiegand signals only if matching succeeds If this option is checked the module outputs the fail ID when matching fails Inverse Parity on Fail If this option is checked the module outputs Wiegand signals with inverted parities when matching fails 4 8 6 Smart Card setting Card Configuration is the process of defining custom sectors on user s smart card to store user information including user ID and templates By selecting Card Configuration menu smart card layout page is updated on the main window Note It is recommended that only advanced users attempt to change the layout since improper changes may render the smart card unusable Read this chapter carefully for changing the layout from the default configuration System Setting I O Setting LED Beep Wiegand Setting Card Configuration Smart Card Layout eee ae Bkkk eae SERRE Template Size Reset Layout Block Color Key HAEA CHEM AJI EEEE m CIS Index Block T Template 1 Data E Unavailable M Unused T Template 2 Data Apply Apply to Others Setto Default Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 223 Editing layout Template size Template size is configurable from 254 to 382 By factory default template size is specified as 350 bytes storing two
19. Wireless Network Key Network Authentication WWPA_PSK Encryption Strength TKIP AES Network Key seeccccecesee Confirm Key eeccceccccess Serial On RS422 485 network a new device can be detected automatically or added by new device search menu in device management Once device is connected to network properly device ID will be displayed with a bracket under port on device tree window Baudrate in RS485 RS232 interface represents the frequency of carrier wave changing status per sec In communicating with BioStation device default is 115200 but if any trouble lowering the baudrate can solve the problem Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 59 Add New Device Search BioEntry Search BioStation Search BioEntry Plus Serial Port COM Port COM Baudrate 115200 O TCP IP IPAddr L USB Device BioStation USB Virtual BioStation UDP BioEntry Plus Search Searching COM1 Detected Device New BioStation 6238 Finish Device Search 1 device s found 2 All Devices ai L BioAdmin Server 1058 New BioEntry Plus 2686 New BioStation Se com SE 5238 New BioStation S 192 168 1 254 H a New BEACon 42965 New BioEntry 42714 New BioEntry Although a device is disconnected from network it still remains on device tree window Remove device menu is used when removi
20. button and check mark to transfer Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 84 Select a Device VJ All Devices MWB BioAdmin Server EI 1058 New BioEntry Plus MME 2686 New BioStation Press Manage Users in Device button and click the device If the area of user information is marked in yellow color it is successfully transferred 2 2 7 Step 7 Monitoring Event list windows will be appeared if selecting Monitoring menu Select Setup Monitoring and double click each event of Real Time Monitoring to change its status as Yes or No Press OK button Press Start Monitoring to start real time event Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual EC BioAdmin Software System User Management Device Management Access Control Event List k Monitoring Task CS Setup Monitoring Ce Start Monitoring CS Pause Monitoring Status Monitoring On Event Door 85 Date Time 2003 10 16 23 29 46 2007 10 17 00 36 37 2007 10 17 00 36 37 2007 10 17 00 36 57 2007 10 16 23 36 59 2007 10 16 23 37 01 2007 10 17 00 37 06 2007 10 17 00 37 08 2007 10 17 00 37 11 2007 10 17 00 37 11 2007 10 17 00 37 Device 42714 2686 2686 2686 42965 42714 2686 2686 2686 2686 2686 Event Identify Fail Identify Success Door 0 Relay On Identify Fail Identify Fail Identify Fail Identify
21. 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 130 3 8 3 9 Delete checked users from device On user list window enrolled user can be deleted by delete checked user from device button Detailed operating process is as follows Select a user to delete Press delete checked user from device button on task window Select a corresponding device on select device display Selected checked user is not deleted on host PC user list To delete it from host PC user list press delete checked user button Note Be careful in selecting a device in a network because it is a task to delete user information from selected device Manage users in device Manage users in device is to upload user information from device to host PC database User information such as user ID fingerprint information access group number security level is uploaded thru this process In this menu you can upload user database selectively from chosen device on network Select Target Device Device List Template Information All Devices User ID Number ofT Access Grou Security Level Check QB BioAdmin Server SE 1334 New BioStation E 192 168 1254 B 254 New BEACon E 943 New BioEntry 1050 New BioEntry FF 192 168 1 74 SC 1539 New BioStation Check All Il Uncheck All Check Reverse Delete Selected Us
22. 9 2 2 Time setup Select time setup menu on time attendance code definition page and set time attendance time as follows Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 261 Time Attendance Code Definition Attendance Code New Attencance Code Device Setup Time Setup BioStation Function Key Setting Time Setup From o 00 Fs Start of a new day Minimum Work Hours o hour s Check In Time 98 Check Out Time 17 Overtime Limit from 18 to 00 Minimum Overtime 2 hour s Nonworking Time 00 00 zm 00 00 00 00 lto 00 00 00 00 i Sij to 00 00 Detailed setting process is as follows Set standard time of work start in from start of a new day Set minimum work hrs of applicable day in minimum work hrs In case work hrs is less than set minimum work hrs absence is applied to report In case of setting minimum work hrs as 0 this function may not be used Enter check in time Enter check out time Enter maximum overtime hours In case one works overtime more than set maximum OT hrs such hrs are not included in report as OT Enter minimum overtime hours In case of working overtime less than set minimum overtime hours such hours are not applied as overtime in report Set up Nonworking Time to exclude certain period of time from work time This time will not be included in the working hour on report You can select up to three Nonworking Time a
23. DER Entrance limit Setup Device Setting Get Time Set Time No Time No Time Always No Time 1 N Schedule T amp A Mode Always Not Use l Refresh Apply Apply to Others Set to Default Suprema Inc Once the BioStation is connected to the BioAdmin Server connected BioStation will be added to the device tree whenever you start the BioAdmin software Also you can see the connected BioStation by pressing the Refresh Device List Even though a BioStation is properly connected to the BioAdmin Server it may take several minutes to show up on the device tree if a BioStation is unauthorized one an orange color is indicated on the BioStation icon In this case you can not communicate with that unauthorized BioStation Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 54 NE Eu All Devices WLAN E L BioAdmin Server Live S 192 168 1 77 ched Statis W 5238 New Set Time i 192 168 1 254 Gs 1 New BEA Rename Device 42965 42714 Remove From Server Issue Certificate of Device Reset Device l To communicate with the BioStation select the unauthorized BioStation and press the right button of the mouse Press Issue Certificate of Device menu After issuing the certificate you can use this BioStation Because the BioStation restart after issuing this certificate
24. Generally inside installed device sends open relay for secure purpose SO BioEntry Plus sets as Host and BioStation sets as Slave via RS 485 connection 1 Go to Network Setting of BioEntry Plus 2 Select Host mode in RS 485 setting 3 Type ID number of BioStation as a slave 4 Go to Network Setting of BioStation 5 RS 485 should be Slave in RS 485 setting Case 2 BioStation at outside door and Secure I O at inside for high secure BioStation as a Host controls Input output of Secure I O If verified successfully BioStation open a door via Secure I O 1 Select BioStation as a Host and check SIO Max 4 to control 2 Type assigned number from back side of Secure I O by controlling DIP switch 3 Control door or siren via basic In Out of Secure I O Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 170 4 5 4 Serial RS232 Set baudrate of BioStation s RS232 ports Default is 115 200 bps As to serial in case of any trouble in condition of cable lowering baudrate can be a solution USB Setting Select whether or not to allow connection with host PC via USB port of BioStation As USB port is exposed to outside in some cases connection is not allowed for security reason Function key Function key is to input T amp A event before fingerprint input for T amp A control such as in out in duty or out duty In BioStation usually function
25. Input amp inputi Exiit Switch Wiegand card Wiegand user or Disabled Output0 amp Output Choose from duress tamper switch authentication success authentication fail wiegand card wiegand user and disabled Signal output time of output port can be set in msec unit Tamper switch in case BioStation case is open choose whether or not to set system lock mode for security reason Relay Relay Driven By ai Events v Duration sec 3 Lock Time None K Interphone Disable K RE 1 Unlock Time None vi Relay On Relay Off Driven By Choose from all events auth selected events auth selected events and disabled In case of selected events user can set door open time Lock Unlock Time Door lock time and unlock time can be set separately by day holiday zone which should be set in advance in time zone setting on access control menu Duration relay running time as per set event Once door is released door can be locked again after set door open time interphone Enable this option when you are using a interphone along with BioStation Relay On Off Administrator can control the relay of the BioStation by using this Relay On Off menu Note overall system door open time is computed by adding door lock open Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 175 time and device open time 4 5 6 Image amp Sound Menu to set background
26. Password TimedAPB Minute BST Admin Leve Normal User x 3 5 1 User information In user information you j Cancel can enter basic personal information details information access group other information and additional information for BioStation In basic personal information enter user ID name company dept and title For details enter telephone number mobile phone number email gender and date of birth Make sure to check Active in access group Otherwise database in device will be deleted Edit Private Information Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 119 Private Information User ID Display Setting No Limit Delete Photo Private Message Welcomel Change photo and message when succeeded in verification and configure display condition which should be used Private Information of the device Access Group Enter the access group information for each user To apply the designated access group information to each user please check on the Active option and sent transmit this user to the BioStation and BioEntry If you do not check on this option or do not transmit the user to the BioStation or BioEntry access group will not be applied to each user If you check on Bypass ID option that user will be able to access the door just by placing this card to the BioStation without fingerprint or pa
27. Station Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 233 Smartcard Info BioEntry ID 1050 New BioEntry Read Card Smart Card Info Serial No 40399034 Wiegand String 00000000 000006at UserlD 853 Security Level BioEntry Default User Name Dongsuk Suh Access Group 1st Template 2nd Template 1 gt ae J MEP et a at tar meee ie ig a PP A A E EE EE DEET Wee Eat EE d VA CEE Tee CH EE GE hi Ki N GE 4 a A AS N D D D D ran D D D D w Kee ee E Ka SS SNS Bee he A Af nL LL ANA Du n NNR se NS cee ante ew AOS te EH ier o ab TE Lee BE LEE E eee N F SCH d Eet Eer oe bi ei Duress No 5 4 1 Read issued smart card On this Manage Smartcard window information stored on the smart card can be retrieved similarly to the reading process described in Chapter 3 User Management 5 4 2 Smart card format On this Manage Smartcard window the formatting can be processed similarly to the formatting process described in Chapter 3 User Management 5 5 Edit Card Layout Smartcard layout is the process of defining custom sectors on user s smart card to store user information including templates By selecting the Configure Smartcard Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 234 Layout button the smartcard layout
28. The Import from file button is used to upload user database from an external database to BioAdmin Software user database User list saved as CSV Comma Separated Values format can be loaded into user database list Detailed operations are as follows Press the Import from file button Importing Select File to Import Preview Cancel Select a file to upload After selecting the file you can see the content examples of 5 users on the preview window Check the preview window to confirm the selected file is the right file from which you want to upload the database Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Importing Select File to Import 135 File C Documents and Settings tester My Documents test csv Preview JE Column Column2 Column3 853 Dongsuk Suh 861 Nakwon Lee 934 ChangGyun Lee 1144 Hoyoung Gyoung 1205 Gunsaeng Shin Column4 Suprema Suprema Suprema Suprema Column5 R amp D R amp D M amp S R amp D M amp S Ifthe file is correct press the Next button Select a column to upload Importing Field Setup Column Order Data Sample Column 853 Column3 Setup Field Column4 Column5 Select Column to User list field UserID am C Column pennan Columng Columni0 Column 1 Press the Upload button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User M
29. Use data source name BiodminMySQL Use connection string Se string Build 2 Enter information to log on to the server User name bioadmin Password eeeeeeeeeeeg C Blank password 3 Enter the initial catalog to use Test Connection Press Test Connection button to check the connection status Press OK button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 37 BioAdmin Server Config Status ei 3ioAdmin Server V4 2 192 168 1 120 Running Connection dy TCP Port 1480 Max Connection 32 Database WI Database Type MySQL v SaL Connection String Provider MSDASOL 1 Password testtest Persist Security Info Treu User ID bioadmin D ata Source BioddminMySOL OpenSSL Path C Open3SL bin openssLexe Pass Phrase eeccccce Select the database type as MySQL t you were already using the MySQL press Apply button on BioAdmin Server Config Press Stop and Start the BioAdmin server Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 38 BioAdmin Server Config Status ER Connection DN i SR a TCP Port 1480 Max Connection 32 Client List Database WI Database Type MySQL v SaL Connection String Provider MSDASOL 1 Password testtest Persist Security Info Treu User ID bioadmin Data Source BioAdminMy
30. YQ Check Status Refresh Device List Image amp Sound Notice Wiegand Door Setting IO Setting Entrance limit Setting iced oh mass Operation Mode H Network Setting Function Key Device Setting Network T amp A Function i All Devices Function Key Event BioAdmin Server g 192 168 1 87 Function Key In 1058 New BioEntry Plus F com 7 Use this Event D 5238 New Biostation V Activate Relay by this Event Auto Mode Assigned Key Information 1 None 3 None F1 In R 4 None 6 None F2 Out 7 None 9 None F3 Duty In R CALL None ESC None F4 Duty Out R Relay in use l Refresh Apply Apply to Others l Setto Default W Suprema Inc Set 16 keys in device and choose one out of 16 function keys to check function key event message displayed on BioStation LCD use of this function key and relay use Choose a function key to set Enter event name in Function Key field Decide whether or not to check use this event Decide whether or not to check activate relay by this event Relay is usually linked to door lock control device and used to open close a door Note In case of selecting T amp A mode as Fixed at Operation Mode tab you will see highlighted Fix check box which is useful for T amp A management Note In case of selecting T amp A mode as Auto at Operation Mode tab
31. device ID and firmware version of selected BioStation Device ID number and firmware version are necessary information to check a product for technical support after installation Device Info Device Name 5238 New BioStation Device ID 5238 Device Type BioStation BSR OC Firmware Version 1 4_071008 VU Device Name Device Type Device ID Firmware Version 4 5 2 Operation mode Time setting Date and time shown first are those read from BioStation If you click get time button it reads date and time from BioStation once again Method of BioStation time change is divided into direct input and synchronization with current PC time Direct input either input numbers directly in date and time window or place a cursor on a number and click up down arrow keys for input Press set time button after input to transfer input date and time to the selected BioStation Synchronization with PC time check sync with current PC time and set time button then selected BioStation time is set by current PC time BioStation Time Date DI 8 2006 5 O Sync with Host PC Time Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Basic Configuration 161 1 1 Operation Mode if you select 1 1 operation mode on BioStation user ID should be suggested first and then the user should authorized himself with his fingerprint or password which can be assigned by p
32. for breach of warranty with respect to the Product This limited warranty shall not extend to any product which has been i subject to unusual physical or electrical stress misuse neglect accident or abuse or damaged by any other external causes ii improperly repaired altered or modified in any way unless such modification is approved in writing by the Supplier iii improperly installed or used in violation of instructions furnished by Suprema Suprema shall be notified in writing of defects in the RMA report supplied by Suprema not later than thirty days after such defects have appeared and at the latest one year after the date of shipment of the Products The report should give full details of each defected product model number invoice number and serial number No product without RMA Return Material Authorization number issued by Suprema may be accepted and all defects must be reproducible for warranty service Except as expressly provided herein the products are provided as is without warranty of any kind either express or implied including but not limited to warranties or merchantability fitness for a particular purpose Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 3 Disclaimers The information in this document is provided in connection with Suprema products No license express or implied by estoppels or otherwise to any intellectual property rights is granted by this do
33. gt Preference gt Device Time Setting you do not need to synchronize the time on this menu FW upgrade Jegen Device Management Add New Device Add New BEACon Set Time Upgrade Firmware Get Challenge Code Set Challenge Code Site Key Setting By selecting the Firmware Upgrade menu a pop up window for firmware Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 281 upgrade appears Firmware Upgrade BST_ 1_0_060802 bin SelectFirmware ee Select Firmware to Upgrade Select a firmware file by clicking the Search Firmware button Execute upgrade by clicking the Upgrade Firmware button H BioEntry or BioStation is turned off or reset in the process of upgrading restoration might be impossible Firmware upgrade is processed for one device Selection of a group or all devices is not allowed For detailed setting refer to chapter 5 user management Note Once firmware upgrade is complete BioEntry and BioStation are rebooted automatically and connected to network It is recommended not to do any other operation for about 5 10 sec after BioEntry or BioStation are rebooted due to upgrade 10 3 3 Site Key Setting Site Key Wizard Select Site Key to Change O Changing Secondary Key O Changing Site Key Options Only Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 282 To prevent un
34. menu may be selected by clicking right mouse button on BioEntry Plus Icon or a name Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 191 BioEntry Plus Network Setting 192 168 1 87 1058 System Information 1058 Refresh 00 17 fc 20 04 22 Network Setting IP Address Gateway Subnet Mask Server IP Port System Information Show the ID and MAC address assigned to BioEntry Plus at present if clicking Refresh button it reads the information again Network Setting Use DHCP Check it if the BioEntry Plus is to be automatically assigned with IP Use Server Check it if BioEntry Plus is connected to BioAdmin Server and operates Check it to synchronize temporary with server Port Use the same value with the BioEntry Plus port and the server port Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 4 7 3 Operation Mode E BioAdmin Software System User Management Device Management Access Control Device Management Task W Search Device Add New BEACon F Remove Device W Check Status Q Refresh Device List a e All Devices BioAdmin Server CH 192 168 1 87 ZE 1058 New BioEntry Plus GE com SE 5238 New Biostation BioEntry Plus Time Device Info Device Name 1058 New BioEntry Plus Device ID 1058 Device Type BioEntry Plus
35. sound effects and other display sound of BioStation User can set desired background notice and log image and also change sound effect fit for user s style BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info Device Name 5238 New BioStation Device ID 5238 Search Device Ki Add New BEACon gt Renove Deve Gemeng BloStaionBSR 0C FimwareVersion mme W Check Status Refresh Device List Operation Mode Network Setting Function Key Device Setting ES eg Le Sen Image amp Sound Notice Wiegand Door Setting I O Setting Entrance limit Setting Sound vetwork 5 All Devices BioAdmin Server EI 192 168 1 87 1058 New BioEntry Plus a E com W 5238 New Biostation Status way Pie Start Scan Success Error Question Button Detect Finger Place Finger lt Display Sound Language Korean Background Sub Info Time Volume Menu Timeout 20 sec Msg Timeout Resource File No Change g Private Msg Enable Refresh l Apply to Others Set to Default Wa Suprema nc Background Image In this menu user can change background image of BioStation BioStation background can be chosen from logo image slideshow and notice Image file format which can be uploaded to background are varying i e JPG GIF BMP and PNG but size is fixed as 320 240 pixels In case th
36. 3 5 5 button to designate the users card ID Get Wiegand RF ID If you press Get Wiegand RF ID button BioStation RF or external Wiegand card reader will be waiting for the card If the user put his card to the BioStation or to the external Wiegand card reader the Wiegand ID of that card will be registered as the user s card ID Therefore you can use this option to get the Wiegand ID from the card and apply it to the user Use User ID as RF ID If you press Use User ID as RF ID button Wiegand card ID is entered as same as the user ID This menu is useful when the users were already using Wiegand cards of which card ID was set as same as the user ID Input Wiegand RF ID manually If you press Input Wiegand RF ID manually button you can enter the Wiegand RF ID manually 1 1 Security Level You can change the security level for the 1 1 verification of BioEntry and BioStation If a user s fingerprint condition is very poor and he often fails in 1 1 verification administrator may enroll his fingerprint after lowering the 1 1 security level for that user Issue user smart card BioEntry Smart basically operates with users smart card containing user information and fingerprint templates Issuing is required to create the user s smart card Issuing of user s smart card is processed on the user management window which is initiated by double clicking a user on the user list or by pressing the Register New User b
37. BioAdmin User Manual E BioAdmin Software System User Management Device Management Access Control Log List Task g Get Recent Logs Auto Upload CS Stop Auto Uploa RS Upload All Log IS Export Report Status Auto Uploading Off Filtering Tool ding 21 142007 2128 2007 Device ID UserID Event C Source 8 2 4 Upload all logs g List Date Time 2007 02 28 16 00 58 2007 02 28 16 02 16 2007 02 28 16 43 17 2007 02 28 17 11 40 2007 02 28 17 59 55 2007 02 28 20 23 19 2007 02 28 21 21 05 2007 02 28 22 04 59 2007 02 28 22 05 07 2007 02 28 22 05 41 2007 02 28 22 13 17 2007 02 28 22 20 13 2007 02 28 22 36 11 2007 02 28 22 36 12 2007 02 28 22 36 14 2007 02 28 22 36 15 2007 02 28 22 36 16 2007 02 28 22 36 17 2007 02 28 22 36 19 2007 02 28 22 36 20 2007 02 28 22 36 22 2007 02 28 22 36 31 2007 02 28 22 36 47 2007 02 28 22 42 47 2007 02 28 22 42 48 2007 02 28 22 42 50 2007 02 28 22 42 51 2007 02 28 22 42 52 2007 02 28 22 42 54 Device ID 1539 1539 1539 1539 1539 1334 1334 1334 1334 1334 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 Event System Started Delete All System Started System Started System Started System Started Delete All Identify Fail Identify Fail System Started System Started Identify Fail Enroll Success Enroll Success Enroll Success Enroll Succes
38. C Bypass Card Read Card Write Card Format Card Scan Delete Verification Test Press Scan button and put your 1 fingerprint twice for 1 template Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 78 1st Template C Duress X vA Pai E Za ae i Ce fff af aerer ff ei d E 8 8 Dn n n D n n n SES Gen Dn ANN E NN Oe et fff aa oe a Be N N sc a a a gE NN A ai e Ae lf A wee FAAS feierte Aa af PAS ef Sb 44 ef fon Oe te ff of ei A 2nd Template Device ID 1058 New BicEntry Plus 1Y Wiegand Card ID Setup Duress Copyright 2007 by Suprema Inc Delete Put your 2 template same as 1 method above 1 1 Security Level BioStation BioEntry Plus Device Default v BioEntry Smart Pass Device Default v Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Read Card Write Card Format Card http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 79 Device ID 1058 New BioEntry Plus Wiegand Car
39. Durationims 200 Not Use v Device Type Display the device to be set at present Function Select a function to be performed as an input Default Not use Schedule Set the input to be operated only for the time set in access control Always or No Time Output Output Device Tamper Set to designate the function of tamper Port Select one of input terminals set in the selected device Switch Type N O or N C Duration ms Operate as long as the longer time is entered 5238 w Port Relay 0 v Alarm On Event Add Delay ms Hightms Lowi ms Count Priority CH 0 D D Oo Alarm Off Event Priority 0 Add Del All Device type Display the devices to be set at present Port Select an output terminal to be set in a selected device Alarm On Event It may set so that if a listed event occurs the output is Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 186 generated from the port of a selected device How to add Event Add Event 5228 Relay 0 Event Event Auth Success Device 5238 Priority 1 Signal Setting Delay ms 0 Count 1 Hightms 0 Low ms 0 Event Itis set so that if a selected event occurs the output is generated to the port of the previously selected device Device Select a device
40. Fail Identify Fail Identify Success Door 0 Relay On Identify Success Door 0 Relay On TARA Event User ID User Name D 2900002 2900002 0 2900002 Wa Suprema Inc Door If there are already door setting you can see Door monitoring shown as below figure which can be Open Door Close Door and Release Alarm Open Door Apply to actual device Close Door Apply to actual device Release Alarm Does not apply to actual device but only in PC Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual BioAdmin Software Device Management Access Control 86 Monitoring Event List Tesk Event Door TS Setup Monitoring Selected Device Select All Door Ce Start Monitoring Pause Monitoring Open Door Close Door Release Alarm Status Monitoring On C Don Name Device ID Status Last Event Alatmjevent Checked Users 1 Total Users 1 2 2 8 Step 8 Log List f selecting Log List menu it will be appeared in the main window Click Get Recent Logs Auto Upload select a device press OK button then you can see event log data added at log database of host PC Log List K Date Time Device ID Event TABA Event 2007 02 26 11 31 05 1334 Enrall Success 2007 02 28 11 31 06 1334 Enroll Success 2007 02 28 11 31 07 1334 Enroll Success 2007 02 28 11 31
41. False Rejection Ratio is in inverse proportion to each other FRR will increase with higher security levels Default value is Auto Normal Scan Timeout Scan Timeout specifies the timeout period for user input If a user does not make his her finger scanned place smartcard or input Wiegand during this period error will be returned Sensitivity Sensitivity specifies sensor sensitivity to detect a finger On high sensitivity the module will accept the finger input more easily In other hand by decreasing the sensitivity the input fingerprint image will be more stabilized In case of optical models sensitivity to sunlight is also alleviated by decreasing sensitivity parameter Default value is 7 Fast Mode When more than hundreds of templates are stored in BioEntry the matching time for 1 N identification can be very long Fast Mode parameter can be used to shorten the 1 N matching time with little degradation of authentication performance The security level FAR is not affected by this parameter but the FRR can be a bit higher than in normal mode In typical cases Fast Mode 1 is as 2 3 times faster than Normal mode And Fast Mode 5 is 6 7 times faster than Normal mode Default value is 0 Matching Timeout Timeout period for 1 N matching If identification process is not finished during this period error will be returned Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 4 8 3 B
42. Format All Devices Format 26 bit Standard BioAdmin Server 5j g 192 168 187 EAAA AAAA AIII IIII III IIII 10 Total Bits E 1058 New BioEntry Plus a F com S amp 5238 New BioStation pp 16 1 ID bit O ParityBit Odd 1 E ParityBit Even A8 Fields FC Code Disable Field Default Values Refresh Apply Apply to Others Set to Default Suprema Inc Wiegand Format New Wiegand format can be configured graphically using the Wiegand Configuration wizard The Wiegand Configuration wizard will be shown by pressing the Change format button Select format You should select one of the three supported formats in the first page http www supremainc com BioAdmin User Manual 179 Wiegand Configuration Wiegand Format O Pass Through Wiegand Forme Custom Wiegand Format 26 bit standard The 26 bit standard format is most widely used and consists of 8 bit FC code and 16 bit ID You cannot change the bit definition and the parity bits in 26 bit standard format Pass Through format Pass Through format is used when only the format of ID field is known When the Wiegand input string is detected BioEntry device extracts ID bits and starts verification with the ID If the verification succeeds the device outputs the Wiegand input string as unchanged Parity check and advanced options are ignored in this format By definition Pass Through format is only useful when the operation
43. Image Quality Moderate v Security Level Auto Normal v Scan Timeout 10 sec Sensitivity T Highest v Fast Mode 5 Fastest v Matching Timeout infinite Apply Apply to Others Set to Default Operation Mode 1 1 verification if 1 1 mode is selected in BioEntry Smart present user smart card first and finger scan starts In case of BioEntry Pass finger scan is processed by Wiegand input from external device such as ID card or user fingerprint 1 N identification in 1 N mode finger scan authentication is done with user s fingerprint only As device sensor is always on input standby mode 1 N scan starts right away once a finger is placed on Both Both 1 1 verification and 1 N identification are supported Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 209 Baud rate Baud rate is the number of times per second that the carrier signal value changes state If you have some problems to communicate with BioEntry or with BioStation changing baud rate to lower value can be a solution Image Quality When a fingerprint is scanned the module will check if the quality of the image is adequate for further processing The image quality parameter specifies the strictness of this quality check Security Level Security level specifies FAR False Acceptance Ratio If it is set to 1 100 000 it means that the probability of accepting false fingerprints is 1 100 000 Since FAR and FRR
44. Matching Timeout 0 10 sec After fingerprint enrollment it can assign max time in sec until verification result comes If a time is over the assigned time fingerprint search stops without seeing verification result This is specially designed for users who are waiting for longer search time against lower templates 4 74 Network Setting LH BioAdmin Software EIS System User Management Device Management Access Control Device Management Device Configuration Task Device Info fi m p Se coer Deve Device Name 1058 New BioEntryPlus Device ID 1058 Add New BEACon EE SE P Remove Device Device Type BioEntry Plus Firmware Version V1 0_071008 YW Check Status Operation Mode Network Setting Entrance limit Setting Door Setting I O Setting Command Card Wiegand Refresh Device List WEE zl LZ TCP IP Use DHCP O Notuse DHCP Networ D All Devices BioAdmin Server a 192 168 1 87 Port SE 1058 New BioEntry Plus RER a E com 5238 New BioStation Server Setting Use Server Not use Server RS485 Mode Host v Baudrate Slave device 0 Slaon Refresh Apply Apply to Others Set to Default er Suprema Inc TCP IP t selects whether to receive IP address automatically from the settings of BioEntry Plus or be manually set If the IP address is set as DHCP to BioEntry Plus or if directly set
45. New Bcenty Ps 3 F 192 168 1 254 E 1 New BEACon 42965 New BioEntry 42714 New BioEntry Device Configuration Device Info Device Name 1058 New BioEntryPlus Device ID 1058 Device Type BioEntry Plus Time Date 10 16 2007 BioEntry Plus Firmware Version 1 0_071009 o Operation Mode Network Setting Entrance limit Setup Door Setup Secure I O Command Card Wiegand Syne with Host PC Time Time 11 55 20 PM Basic Setting Operation Mode Setting All Always Card Fingerprint No Time Only Card No Time Fingerprint No Time Fingerprint Setting Security Level Normal Scan Timeout 10 GetTime 1 SetTime Double Verification Mode Double Verification Mode Double Verification Mode Double Verification Mode 1 NFastMode Auto Matching Timeout 3 Refresh Apply Apply to Others l Setto Default 73 BioEntry Plus connected to the server is automatically added to the list and also if selecting Refresh Device List it shows the list of newly connected devices Even though accessing BioEntry Plus to the server it may take several minutes until it is actually connected to the server and listed on the window Step 3 Connect a New Device Select Device Management at the Main Window e Select Search Device and click Search BioEntry Plus Check UDP Bio
46. Same Users Users 1 Templates 2 4 Get from Device Close 2 4 5 Step 5 Enroll user ID in the external controller It is required that the issued user ID is also registered to the external controller to grant access when the Wiegand string for the user is received If you are using Suprema s BEACon controller you can just skip this additional registration to the controller 2 4 6 Step 6 Authentication test Amber LED on the device blinks slowly indicating that the device is waiting for finger scan for identification Swipe finger on the sensor If the user is successfully identified steady green LED appears with one beep sound Otherwise red LED appears with 3 beep sounds On successful identification the Wiegand string is also sent to the controller which can be checked by operation of relay on the controller 24 7 Step 7 Monitoring Select Start Monitoring menu to start the real time monitoring on all of the connected BioEntry devices Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual E BioAdmin Software System User Management Device Management Access Control Event List s Monitoring Task CS Setup Monitoring EB Start Monitoring Pause Monitoring Status Monitoring On 2 4 8 Step 8 Check log Date Time 2007 02 28 22 20 09 2007 02 28 22 20 13 2007 02 28 22 04 59 2007 02 28 22 05 07 2007 02 28 22 20 22 2007 03 28 22 19 19 2007 02 2
47. Success When verification is successfully done Verify Fail When the user is not verified Delete Success When deletion of user succeeds Identify Not Granted Identification is successfully done but entrance denied Verify Not Granted Verification is successfully done but entrance denied Delete Fail When deletion of user fails Verify Duress When duress finger is verified Identify Duress When identified finger is a duress finger Temper Switch On When temper switch on the device is enabled implying device is opened Command Card Success When command card operation successfully completed Command Card Fail When command card operation is failed Controller Reject When input port on which Controller Reject function is assigned is activated Controller Accept When input port on which Controller Accept function is assigned is activated Detect Input 0 Detect Input 1 When input port 0 is activated regardless of assigned function When input port 1 is activated regardless of assigned function Describing output pattern On each enabled event output pattern can be flexibly described by programming using 4 parameters whose meanings are depicted as t_high t_delay 1 2 it e _ gt Copyright 2007 by Suprema Inc http www supremainc com 214 BioAdmin User Manual Parameter Meaning Allowed value Delay initial delay before generatin
48. Suprema Inc Suprema Inc 196 http www supremainc com BioAdmin User Manual 197 Timed APB Limit verification if re verification is not attempted for a specified time minute Options 1 4 If entering start time end time of each option and specifying the max access allowance number for the time it allows the only number of access for the specified time Automatic T amp A Mode Change Set in which attendance mode BioEntry Plus is used T amp A mode Not use Fixed in Fixed out Auto Auto Mode if authentication is approved for a specified time its attendance mode is automatically converted to Entrance or Exit Fixed in Fixed out mode Set the attendance mode to either entry or exit among entrance or exit Default Access Group Setting In case of a user with no access group information it may set a user to be grouped in an access group 4 7 6 Door Setting The detail setting of door that is operated by each device may be set up Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual E BioAdmin Software System User Management Device Management Access Control Device Management Task W Search Device a Add New BEACon BH Remove Device YW Check Status W Refresh Device List 1 All Devices BioAdmin Server EI 192 168 1 87 SE 1058 New BioEntry Plus com1 E 5238 New Biostation Device Configuration Device Info Device Name
49. TODD e Uu 1 Enter 32 in the Total Bits field 2 Select ID bits according to the definitions 3 Press Next You cannot specify parity bits in Pass Through mode Custom format When users know all the information of a Wiegand format Custom format can be defined When a Wiegand input string is detected BioEntry device checks the parity bits first If all the parity bits are correct the device extracts ID bits and starts verification with the ID Users can also set alternative values of each field and enable advanced options such as Fail ID If the verification succeeds the device outputs a Wiegand string The output string may be different from the input string according to the alternative values and advanced options For example assume that 44 bit Custom format is composed as follows EAAAAAAA III III BBBBBBBI WII IO left most bit is Oth bit BITO E Even parity for BIT1 BIT22 O Odd parity for BIT23 BIT42 ID bits Field1 and Field 3 A Field 0 B Field 2 You can configure this format in the following sequences Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 220 Wiegand Configuration Format Total Bits A ID Bits 28 Format co DATATE gt Ouer Enter 44 in the Total Bits field Select Even Parity Press the even parity bit In this example it is BITO Select Odd Parity and press the odd parity bit and User ID according to t
50. User Manual 4 4 2 3 We Bites L BioAdmin Server 192 168 1 77 SE 5238 New BioStation gt Virtual USB Device E T 2686 virtual BioStation SF 192 168 1254 R I New BEACON 42965 New BioEntry 42714 New BioEntry Status of each device is updated in case of the followings When BioAdmin software starts When a device is selected anew When clicking check status menu When connecting BioStation to host PC via USB Zone List 150 Zone List can be configured as some grouping to manage and control connected each device then display a list If you click Zone List you can see zone list combination of each device In case of no Zone setting it display as Stand Alone in the sub device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual BioAdmin Software System User Management Device Management Access Control Device Management Task g Search Device Add New BEACon F Remove Device W Check Status Device Configuration Zone Information Ee 151 Q Refresh Device List Zone Properties a e All Zones 7 Stand Alone 5238 New BioStation 1058 New BioEntry Plus Sub zone 2686 New BioStation No Zone Name Zone Type Zone M Suprema Inc Adda Sub Zone Click right button of mouse on the device to make Master Device for a zone and you will see Cre
51. User Manual 139 Add New Device Search BioEntry Search BioStation Search BioEntry Plus Serial Port COM Port com Baudrate 115200 O TCP IP IP Addr USB Device BioStation USB Virtual BioStation UDP BioEntry Plus Search Searching COM1 Detected Device New BioStation 5238 Finish Device Search 1 device s found Press search button to display search result Press ok button to display searched device on device list The number in bracket ahead of searched device name is device ID To change device name place a cursor on applicable device and press the right button of the mouse to display a menu Choose change name then input window appears where a new name can be entered S BioAdmin Server 1058 New BioEntry Plus 2686 New BioStation Se com SE 5238 New BioStation i 192 168 1 254 Gs New BEACon 42965 New BioEntry 42714 New BioEntry Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 4 1 2 Ethernet 140 In case device and host PC is connected by Ethemet enter IP address and pot in TCPIIP field on add new device window In case of BioStation and BEACon IP address can be checked in device For details refer to manual of each device In case of BioEntry Ethernet interface is not supported but can be linked by Ethernet using Ethernet to Serial converter in host PC Input IP address o
52. above configuration Attendance Rule Group List Code Name Sun Mon Tue Wed Thu Fri Sat New T amp A rule group New Aen NewAtten New Atten New Atten New Atten New Atten New Atten Delete Press Add button to generate new rules on T amp A group and configure each specific rule Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 9 4 1 9 5 Copyright 2007 by Suprema Inc T amp A Rule Group Name Daily Rule Sunday Monday Tuesday Wednesday Thursday Friday Saturday Holiday Setting Holiday Schedule Holiday Group Holiday Group Monthly Schedule C Set as default New T amp A rule group 2 New Attencance Code v New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Attencance Code All holiday Not Use New monthly schedule Save Close Use as default 265 By checking on set as default apply selected T amp A rule as basic rule In case T amp A rule is not set for certain users basic rule applies to such users How to prepare report http www supremainc com BioAdmin User Manual 266 Report List E Filtering Company None O B Department None EI User ID 0 User Name l Report Type Daily Report O Daily Summary O
53. are as follows Press the Add New Time Code button Time Code Definition Time Code Name Eeer Time Code Term 1 2 Type directly Term 2 SCH Clear Table Term 3 Term 4 Term 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 I II Input the name of time span Input the time in a box and set the time code Time span may be easily set by dragging the time bar displayed on the bottom Time code is also set by dragging it to the bottom of Window If directly entering time click Direct Input button In case directly inputting the time each space is changed to be entered If completing the entries press Apply to save them If directly entering and dragging the timer bar on the bottom the set values are changed into the contents in the selected time bar In addition please note that all other times shorter then 10 minutes it is changed to 0 or 10 minutes Click OK button to add time span to the list of time span Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 239 6 2 Holiday setting To include holidays on the Time Zone you need to set up holidays in advance Detailed operations are as follows P
54. by RS232 422 485 Also BioStation can be use with host PC via USB interface For details on installation refer to BioStation installation manual Step 2 Search new device Run BioAdmin software Enter login ID and password Select device management on main menu to display device management page on main window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual BioAdmin Software f System User Management Device Management Access Control Device Management Task W Search Device GB Add New BEACon F Remove Device W Check Status Q Refresh Device List ork D I All Devices BioAdmin Server ag 192 168 1 106 2686 New BioStation S 192 168 1 77 SE 5238 New BioStation o E 192 168 1 254 8B 1 New BEACON 42965 New BioEntry 42714 New BioEntry Device Configuration Device Info Device Name Device Type BioStatian BSTW TC Image amp Sound Notice Operation Mode BioStation Time Date 10 16 2007 Time 10 40 13 PM Basic Configuration 1 1 Operation Mode ID Fingerprint ID Password ID Fingerprint or Password Card Only 1 H Identification Auto Function Key Function Key Double Mode No Time Encryption Information Encryption Disable 2686 New BioStation Wiegand Network Setting Device ID Firmware Version Door Setup Function Key Syne with Host 2686 V1 4_071008 V01 Secure I O PC Time 53
55. card For the detailed operation refer to the issuing procedure on the User Management menu Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Device ID 3143 New BioStation ze Wiegand AF ID Setup 1st Template 2nd Template C Duress C Duress aa ono ee P mi e a aa aa aa aa Ee e Sf e ir E De Del f f ng te Geelen NS fF eegenen bw Su et tt of PRPP abe a get at att ot att at of of of Ot ft ff ee eG Oa ae EE d f f l f H H Se D D Dn Dr Dr D D Ce D n SS N SE e 0r P a a ie gate gle gt ge gh gee 8 CN A E EE Ee egen ee ema al a ae wan e kg S DA Manage Smartcard 232 1 1 Security Level BioStation Device Default K BioEntry Device Default Mj Smart Card AF ID Smartcard S N 5 N 0 RF 000 0 User ID UserlD 853 C Bypass Card Verification Test The Manage Smartcard menu enables a pop up window to read the smart card information and format smart card On this window you can check the smartcard information such as Serial No Wiegand string if applicable User ID Security Level User Name Access Group and Template Data If you do not have a USB smart card Device Writer you can also read the smart card information directly through BioEntry by check on Use BioEntry as Enroll
56. default on BioEntry device Connect the device with the controller as shown on the following configuration BioEntry Smart Wiegand I F Z 2 O S Ka Access Controller 9 24Vdc To other controllers or host computer Fingerprint Reader Smartcard Reader For more details on the installation refer to the BioEntry Installation manual or Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 88 BEACon Operation Manual 2 3 2 Step 2 Enroll user Run BioAdmin software Enter Login ID and password By factory default the initial Login ID is admin and the password is blank Select User Management on the main menu then the user management page appears on the main window B BioAdmin Software Ce System User Management Device Management Access Control User Management User Management Task User ID User Name Company Department Template Num Active ER Add New User ER Delete Checked Users Bn Transfer checked users to device D I Delete Checked Users from Device ine Manage Users in Device en Synchronize All Users IS Export to File RA Import From File There are no items to show Selection Tool Check All Uncheck All Check Reverse Check Selected Users Uncheck Selected Users W Suprema Inc Select the Add New User menu on the task window then the pop up window appears Copy
57. it may take a few minutes to show this BioStation again on the device tree After the certificate is issued for the BioStation orange mark will be removed from the BioStation icon This means that you can communicate with the BioStation without any problem E Di All Devices E L BioAdmin Server 2686 New BioStation Si 192 168 1 77 SE 5238 New BioStation S 192 168 1 254 8B 1 New BEACon 42965 New BioEntry 42714 New BioEntry Select Search device menu click BioStation search select a desired network out of serial port TCP IP and USB device BioStation and press search button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 55 Note If you find a device from search results Ex searching 192 168 1 101 port 1470 Detected device new BioStation device number Finish device search Search result device s found is displayed Press OK button to select a device Add New Device Search BioEntry Search BioStation Search BioEntry Plus Serial Port COM Port Baudrate TCPIIP IPAddr 192 168 l 1470 OUSB Device BioStation USB Virtual BioStation Search Searching 192 168 1 77 port 1470 Detected Device New BioStation 5238 Finish Device Search 1 device s found Once it s connected to device successfully new device ID and network connected to device are also displayed in device
58. keys from F1 to F4 are used and if necessary it can be increased up to 16 keys Pressing function key on BioStation first and then enter fingerprint to record applicable T amp A even in a log In the future T amp A SOFTWARE this log information can be used for various T amp A and salary control data In respect of function key in BioAdmin software reference needs to be made to all explanations on T amp A event rule in both device management menu and report menu Function key setting in device management menu is to set T amp A event message shown on BioStation display whereas T amp A key setting in report menu is to set T amp A event message applied when creating T amp A report In BioStation log actual T amp A event message is not recorded but the number of pressed T amp A key is recorded BioAdmin reads this value refers to the table between previously defined function key and T amp A event and generates suitable T amp A report Thus function key set in this chapter doesn t show in an actual BioAdmin report or upon log check Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 171 BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info Gi A y erdi Device Device Name 5238 New BioStation Device ID 5238 Bi Add New BEACon Al Bee B Remove Device Device Type BioStation BSR OC Firmware Version V1 4_071008 v03
59. mark new device to modify network setting Depending on the network environment administrator can select DHCP or USE Server Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 146 BioEntry Plus Network Setting 192 168 1 87 1058 System Information 1058 Refresh 00 17 f 20 04 22 Network Setting IP Address Gateway Subnet Mask Server IP Port The default port of BioEntry Plus is 1471 Can be modified After finishing network setting you can find the added new device in Device List The right click of mouse button on the device is also available Note In case of checking Use Server in the BioEntry Plus Network Setting please follow the below setting as Server IP IP addressi of PC nstalled BioAdmin Server program Port Port number used in BioAdmin Server program Default 1480 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 147 4 2 Add New BEACon Searching and adding process of BEACon Add BEACon Serial COM Part Baudrate TCP IP IP Address 1 254 Port New BEACon BEACon ID 1 BEAConName New BEACon BioEntry 1 42714 BioEntry 2 42965 Detailed operations are as follows Press the Add New BEACon button on the task box Select the communication method between Serial and TCP IP In case
60. page is updated on the main window It is recommended that only advanced users attempt to change the layout since improper changes may render the smart card unusable Read this chapter carefully for changing the layout from the default configuration Change Smart Card Layout Smart Card Layout Pe LlUILL IRR l Bi ijili SERRE REE Template Size Block Color Key mM CIS Index Block T Template 1 Data E Unavailable IT Unused T Template 2 Data 5 5 1 Configuration of smartcard layout edit page The Configure Smartcard layout page is divided into 3 sectors Smart Card Layout It shows the smartcard layout of the Smartcard Device Writer device connected to the host PC Smart Card Layout It shows the name of currently selected device and the layout of the current device If a group or all devices are selected the contents are not available New configuration This sector is used for editing new layout to be applied to the devices and the User e smart card Controls for managing layout Fill with Current Configuration Value button updates the contents of the new Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 235 configuration using the retrieved layout from currently selected device Transfer button transmits new layout to the selected BioEntry device selected group or all BioEntry devices Several control buttons for editing layout also exist 5 5 2 Size of Fi
61. rather than BioStation Search new installed BioEntry Plus within same network bandwidth Select the detected BioEntry Plus device Make BioEntry Plus network setting In case of DHCP environment BioEntry Plus is automatically assigned IP address In case of not supporting DHCP environment BioEntry Plus is temporarily assigned IP address so network administrator has to assign valid IP address Not to conflict with other IP address only one device is detected and administrator has to assign each device in sequence Copyright 2007 by Suprema Inc http www supremainc com Add New Device Search BioEntry Search BioStation Search BioEntry Plus Serial Port COM Port Baudrate O TCP IP IP Addr UDP BioEntry Plus Detected Device New BioEntry Plus 1058 192 168 1 87 Finish Device Search 1 device s found Check mark UDP BioEntry Plus in Search New Device window click Search button then all connected BioEntry Plus devices are detected which may take a certain minutes depending on the network traffic or line condition You may click Search button again for not detected devices Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 145 Select Detected Device Check the device to add and click OK Check All Uncheck All Cancel Press OK button then Detected Device Selection windows is appeared Check
62. rule button to set a new T amp A rule Time Attendance Rule Code Name CheckinTime CheckOutTime Check In Device Check Out Device New Attencance Code 08 00 17 00 Incase of pressing add button time attendance rule window appears Time Attendance Code Definition Attendance Code New Attencance Code Device Setup Time Setup BioStation Function Key Setting Reader Setup Separate Check In Check Out Devices Using Function Keys BioStation Select Device Use All Devices to collect attendance data Use Selected Device to collect attendance data Cancel Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 259 Enter attendance code 9 2 1 Device setup Select device setup menu on time attendance rule page and set In Out input device as below Time Attendance Code Definition Attendance Code New Attencance Code Device Setup Time Setup BioStation Function Key Setting Reader Setup First Check In Last Check Out Separate Check In Check Out Devices Using Function Keys BioStation Select Device Use All Devices to collect attendance data Use Selected Device to collect attendance data ES Ss eer pp yer Incase of choosing first check in last check out user applies first authorized time as check in and last authorized time as check out Incase of choosing separate check in check out devices
63. s technologies and products please visit Suprema s website http www supremainc com or contact by e mail sales supremainc com About This Manual This is an introduction to operation of BioEntry BioEntry Plus and BioStation This manual describes how to manage templates properly adjust relevant parameters enroll or delete templates etc The purpose of this manual is to provide instructions to using BioEntry and BioStation and troubleshooting tips Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 6 Table of contents Table of Contents cx e cece Gee aaea a ra a aea ae eine ne ieee eee 6 T Getting SUA EE 15 yy EE en E 15 zs RSCTA EE 15 ENN Sie Ge 15 1 2 2 Finger scan smart Card GEVO AEN 15 UE ele 16 TZA ite Au EE 16 T25 M usiiehech ante hatin adi AE EE dds 16 JPA SE o D e E A EE ET EEN EE E E E E T E EN 16 1 2 7 User database 246th aaa NEE EAA EEA AA 16 1 2 8 Transfer i nice i iia dee nite ida iii at nl daca Eaa iiA 17 1 2 9 Site key for smartcard sssrinin arna ar AA E EEE S EET Ea 17 EC Howto e Cu e EE 17 13 1 Selecta Metro 17 1 3 2 How to place a finger ON a gemet EEN 17 1 3 3 Tips for different finger Copdtonms EEN 18 1 3 4 Advices on fingerprint enrolment EEN 18 1 4 Concept of BiOAGMIN A 7 18 1 4 1 How to install BiOAGMIN Gene e 19 1 4 2 How to install BiOAGMIN Che NEEN 31 1 4 3 Using MySQL or SQL Server datzabase ENEE 33 1 4 4 Check the
64. templates on the card CIS index block Header information is stored on the CIS index block which is depicted by red color Template data block Blocks for template 1 data and template 2 data Number of blocks for each template data is determined by template size Template 1 data is depicted by yellow and template 2 data is depicted by green respectively Unused block Blank block which is not defined by layout Unavailable block Block that is prohibited from use Editing procedure To configure customer s layout following procedures are required Initialize all the blocks to unused ones by pressing the Reset Layout button Select the required template size Press the Select CIS Index button and click an unused block to select a CIS index block Press the Select Template button and click an unused block to indicate the start block of template data Then the blocks of template 1 data are set automatically from the selected start block Press the Select Template button again and click an unused block to indicate the start block of template 2 data The Apply button transmits smart card layout to selected devices Factory default layout BO FP PPP PRP EER Ta aa ca ac GG GGEE GOO clalc BRHEDRRHEERRREER CIS Index Template 1 Data E Unavailable Unused Template 2 Data Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 224 4 9 BEACon Configuration By selecting a BEACon on the D
65. the encryption setting to the remaining BioStation devices You should be very careful in using the encryption function If you are set different encryption key among BioStation devices you may not be able to use the user s template compatibly among those devices f the encryption key on host PC is different from that of BioStation or if only either of host PC and BioStation is using the encryption option following warning message will appear whenever such device is found on the network If you press No such BioStation devices will be disconnected from the network BioAdmin Software Found the device having different encryption setting For changing this setting all user data must be deleteed from the device IF you don t want to change encryption setting you can t use the device Do you want to delete all user data and change encryption setting to device ID 1811 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 10 1 8 10 1 9 10 2 Copyright 2007 by Suprema Inc 278 BioAdmin information About BioAdmin BioAdmin Y 4 2 0 76 Copyright C 2007 by Suprema Inc httpviwww supremainc com About BioAdmin on menu bar represents information on BioAdmin in use Reconnect Server In case of bad communication user can reconnect server to communicate again BioAdmin 4 2 A Reload all data from DB User Management http www supremainc com BioAdmin Use
66. the Time sync with Server the time of BioStation will be automatically set as the time of the server If the network between a BioStation and BioAdmin Server is not stable you can reconnect the BioStation to the server Select the BioAdmin Server on the device tree window of Device Management menu and press the right button of your mouse Press the Reconnect Server menu You can also find this Reconnect Server menu on the System menu of Command Menu Bar E Di All Devices Serial RS 485 Use for RS 485 communication of BioStatiobn In RS 485 mode the connected devices take a role as Host and Slave Suprema s new total integrated system including BioStation BioEntry Plus and Secure I O are consist of 1 host device 1 slave device and max 4 Secure I O Host device has total 10 relay and 20 inout Please refer to the Secure I O Installation Guide for further information Mode PC Connection Host Slave None Baudrate Slave Device SIO default Setting Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 169 Emergency Operation Setting Device Secure VO 0 v Input Port Input 0 Switch Type Hi Durationims 9 Output Port Output 0 High ms oO Low ms 0 Count 0 Save Cancel Here are some examples of RS 485 connection Case 1 BioStation at outside door and BioEntry Plus at inside
67. the USB memory as a correct USB drive Thus user should not change or remove the file in the USB drive You can add a virtual terminal to the network by the following procedures Register a USB memory as a virtual terminal You can do so with the Initialize menu of the Network USB memory menu on BioStation For the detailed Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 142 operation please refer to the BioStation User Guide After registering a USB memory as a virtual terminal connect it to the host PC Check whether your host PC properly recognizes the virtual terminal as a drive e e Select the virtual terminal on the Search Device menu Select the drive of the connected virtual terminal and press Search button e After finding the virtual terminal press OK button Add New Device Search BioEntry Search BioStation Search BioEntry Plus Serial Port COM Port Baudrate O TCP IP IP Addr O USB Device BioStation USB Virtual BioStation Scanning USB Devices Detected Device Virtual BioStation 2686 Finish Device Search 1 device s found Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 143 E L BioAdmin Server SE 1058 New BioEntry Plus o gt Virtual USB Device E i 2686 Virtual BioStation 4 1 5 UDP BioEntry Plus BioEntry Plus is to add a device using UDP function
68. to generate an event Priority By allowing priority to a function it may prevent a priority event from being hidden or turned off preceding over low priority function Signal Setting Delay delay time before output is generated Count frequency to repeat off on interval High time when output is generated Low time when output is not generated Alarm Off Event If a listed event occurs it may release an output of which priority is equal to or lower than the priority of the port of a selected device 4 5 11 Entrance Limit Setting Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 187 BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info KG A y erdi Device Device Name 5238 New BioStation Device ID 5238 ES Add New BEACon gt BH Remove Device Device Type BioStation BSR OC Firmware Version V1 4_071008 v03 YQ Check Status Refresh Devies List Operation Mode Network Setting Function Key Device Setting GE _ Image amp Sound Notice Wiegand Door Setting I O Setting Entrance limit Setting etwork Entrance Limit Setting ES Al Devices a i Li 0 g Bio dmin Server TimedAPB min A 192 168 1 87 m 1058 New BioEntry Plus Option 1 Max Number of Entrance a E com S amp 5238 New BioStation Option 2 Max Number of Entrance Option 3 Max Number of Entranc
69. verification Default 2sec Chk Duplicate FP Check whether it is duplicate fingerprint or not when a user enroll their fingerprint which can protect and identify same fingerprint with two IDs Fast mode In case more than hundreds fingerprints are saved in device 1 N mode may take longer If you set fast mode as fast or fastest performance is somewhat low but 1 N recognition can take less time Default is normal View image User can choose either to yes or no to view or hide input fingerprint image on LCD display of BioStation Default is Yes Scan timeout User can designate the standby time when entering fingerprint If a user doesn t enter fingerprint within this time it is construed as input failure Default is 10 sec Matching After fingerprint enrollment it can assign max time in sec until verification result comes If a time is over the assigned time fingerprint search stops without seeing verification result This is specially designed for users who are waiting for longer search time against lower templates Input Output BioStation provides 2 respectively programmed input and output which can be connected to external device In input output menu set input output port Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 174 InputfOutput Input 0 Disabled v inputi Disabled v Output 0 Disabled v Output 1 Tamper Switch v Tamper Switch None J Duration ms 2000
70. window Press select button to transfer user information database in device from host PC to device Note By transferring all users to device surplus users in devices will be deleted 3 11 Export to file The Export to file button initiates saving information of selected users in CSV format Fingerprint templates are not included in this exportation Exported CSV file Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 133 can be edited using Microsoft Office Excel or usual text editor Detailed operations are as follows Check on the users to export Press the Export to file button User Data Export Select fields to export Field list Selected Field list a Mobile 3 Access Group Access Group2 Access Group3 Access Group4 Issuing Date Expire Date Card No Fax IP Addr A memorial day Married User ID User Name Company Department Title Gender Date of Birth Hobby Room No Select fields to export You can select the target fields simply by moving the target fields from Field list to Selected Field list Select a file to export Press Export button Exporting Export Result After selecting the fields press the Next button After selecting the file press Next button Exporting success Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 134 3 12 Import from file
71. www supremainc com BioAdmin User Manual 204 Wiegand Configuration O Pass Through Wiegand Format Custom Wiegand Format mrm Coma Pass Through Wiegand Format Pass Through Format is used as long as ID field format is known If Wiegand input string is detected the device finds ID bits and starts the authentication with the ID If authentication is successful the device outputs the Wiegand input string with no change Parity check and advanced options are disregarded in the format According to the definition Pass Through format is available only when the use mode is 1 1 In case of use mode is 1 N bit order except ID field should be set to 0 Assuming that 32 bit Pass Through format is as follows II AX XXI MINX the very left bit is Oth bit BITO I Id field X Unknown field The format can be set as the following sequence Wiegand Configuration Format Total Bits 32 Apply pm 26 gt CAEN MEA e use wel ee PIECE 21 even Party 2 DAPATAN HAAT o cca Pay as TO SED e undefined Coste Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 205 Input 32 into Total Bits field Select a ID bit according to the definition Press Next button In pass through mode parity bit may not be specified User defined Wiegand format If a user has the overall information for Wiegand format the user may set the customized format If Wieg
72. 08 1334 Enrall Success 2007 02 28 11 31 09 1334 Enroll Success 2007 02 28 11 36 26 1334 Identify Mode 2007 02 28 12 00 51 1334 Delete Success 2007 02 28 12 00 51 1334 Delete Success Copyright 2007 by Suprema Inc User ID 2 3 853 861 934 1 1 2 User Name Source d BioStation BioStation Dongsuk Suh BioStation Nakwon Lee BioStation ChangGyun Lee BioStation BioStation BioStation BioStation http www supremainc com BioAdmin User Manual 87 2 2 9 2 3 2 3 1 Step 9 Reports Select report menu to display report list on main window You can specify company name dept name user ID and user name for setting and select required type of report such as daily report by setting period or individual report e Upload log is a button to upload a log saved in device and update report button is a button which implements display prior to output listing a log uploaded device by date and individual Lastly view report is a button to preview a report Press print button to print Quick start with BioEntry Smart This section describes the basic procedures to operate BioEntry Smart using a USB fingerprint scanner and smart card device as its enrollment device Step 1 Hardware installation In this hardware configuration the device is not connected to the host PC but to an external controller via Wiegand interface It is assumed that the controller supports the standard 26 bit Wiegand format as
73. 2007 Manager Absence 10 4 2007 853 Date 10 5 2007 Manager Dongsu Date 10 4 2007 10 5 2007 853 Date 10 6 2007 10 6 2007 853 B Date 10 7 2007 10 7 2007 853 S Date 10 8 2007 tnlolonn oca Press view report button Copyright 2007 by Suprema Inc Manager Manager Manager Dongsu Dongsu Dongsu Absence Absence v W Suprema Inc http www supremainc com BioAdmin User Manual Individual ser Name D 83 7 1 2006 7 10 2006 7411172004 741212006 711312006 741472006 7115 2006 7116 2006 741712004 7118 2006 741912004 7 2 2006 7 20 2006 7 21 2006 7 22 2006 7 23 2006 7 24 2006 772572004 7426 2006 7 27 2006 7 28 2006 7 29 2006 73 2006 713012006 743112006 7 4 2006 7 S 2006 76 2006 TITRE 7 8 2006 77972006 Rao ReaD Rao RAD Rao Rao Rao mao nao Roo Rao Rad Rad kad ReO ReO Reo RRO RaO Rad Rao neo nao ReaD Rad Rao Rao Dap Rao man Manager Manager Manager Manager Manager Manager Manger Manager Manager Manager Manager Manager Manager Manager Manager Manager Manager Manager Manager Manager Manager Manager Wednetday September 27 2006 11 47 20AM Press ae to save a file in varying formats Press a to print out the report 9 6 Edit Data gt gt 3 gt gt gt gt gt gt gt gt ee ee Holiday Holiday 268 7 1 2006 8131 2006 Pav
74. 238 New BioStation BioStation BSR OC Notice Wiegand Door Setting Network Setting Get IP address by DHCP Ouse NotUse PC Connection 115200 Refresh Device ID 5238 Firmware Version 1 4_071008 V03 I O Setting Function Key Entrance limit Setting Device Setting Port 1470 O Set IP address manually Max 1 115200 v Serial RS 232 Baudrate USB Setting Enable USB port O Disable USB port Apply to Others Set to Default Suprema Inc To setup the wireless network you need the following procedures First you need an access point Each access point has its own SSID and in some cases it use the data encryption BioStation supports WPA_PSK and WEP as the data encryption methods Refer to the manual of your access point device and check whether it is using the data encryption If yes you need to check the type of the data encryption Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 166 WLAN Setting Preset Preset 1 v Change Setting Preset bio_linksys ESSID bio_linksys Auth mode Open System Encryption WER Preset To activate the wireless network you should select one of the 4 preset Of course you can not use the wired LAN upon using wireless LAN function BioStation WLAN Setting Preset Name bio_linksys ESSID bio_linksys Wireless Network Key Network Authentication Open System Enc
75. 253 3 2 4 Uploadiall lOGS EE 254 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 12 0 2 5 EXDOM ep Ee EE EE Ee 255 3 2 6 Delete e Hd un TEE 256 9 REDONS ee eegene enee eege eier 257 9 1 Configuration of reports PAGS EE 257 9 2 Setup attendance rule AEN 258 ENN DAN E E L a SE 259 92 2 UE E 260 9 2 3 BioStation function key setting ANEN 262 9 3 Setup Monthly Schedule E 263 9 4 Group Configuration for T amp A Control esrtegtegtueee tege 264 GE 265 9 5 HOW lo prepare E EE 265 9 6 Editi Data EE 268 10 Menu ee e TEE 271 LR EN WE ga a ee eee eee 271 10 1 1 Manage Admin account AEN 271 10 1 2 Data ee le DT 271 NIR Eu REENEN 271 TOTA Lock alli devices EE 271 TOTS Unlock e E 272 10 1 6 Load BioAdmin 1 X data ENEE 272 UE 272 10 1 8 BiOAGMiIN infOrrMation eseeceseesececeseseceseeseeeeesecseenseeseseeccesseeeaesesecstsnseeeeeeseeseeeetsesetatenseeetantes 278 10 4 9 RECONNECE E 278 10 2 User Mamagermentt cccccccesesessesesscesesesseseseceetessesessneaesescecnesneaneasenseesensesenennenss 278 10 3 Device Management EE 279 10 3 1 Time setting anssi inania iEn aa E NNE eiS SEEDEN SA 280 RECKEN 280 10 3 3 Site Key Setting 3 0 1 ste EE EE 281 UE ACCESS CON Ol E 283 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 13 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Revision History
76. 74 KR 1539 New BioStation 8 2 5 Export Report Log data can be exported to CSV file format using the Export Report button Detailed operations are as follows Press the Export Report button Select fields to export by simply moving the target field from Field List to Selected Field List Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 256 8 2 6 Exporting Select fields to export Field list Selected Field list Date Time Device ID Event T amp amp A Event User ID User Name Source i Cancel After selecting the fields press the Next button Selecta file to export After selecting the file press the Next button Press the Export button Exporting Export Result Exporting Success Delete Log information The Delete Log Data button eliminates selected log data from log database on host PC Log data on BioEntry and BioStation are not removed by this command but automatically removed only when the device requires space for additional log data Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 9 Reports Report menu includes the followings operations Setup attendance rule Upload log from device and create T amp A event report Export a created report to file Print created report EC BioAdmin Software System User Management Device Management Access Control Report List Task Filt
77. 8 22 20 25 2007 02 28 22 20 28 2007 03 28 22 19 22 2007 03 28 22 19 30 2007 02 28 22 20 37 2007 0 40 Device ID 1050 1539 1334 1334 1050 943 1050 1050 943 943 1050 Event Identify Success Identify Fail Identify Fail Identify Fail Identify Success Identify Success Verify Fail Verify Success Verify Success Identify Success Verify Fail Identify T amp A Event 112 User ID User Name Source Freescan BioStation BioStation BioStation Freescan Freescan Wiegand Wiegand Smartcard Freescan Wiegand Wa Suprema Inc Select the Reports menu Then the report list window appears on the main window Select the Get Recent Logs Auto Upload button to see the updated event log data added to the existing log list of BioAdmin Log List Date Time 2007 02 28 11 31 05 2007 02 28 11 31 06 2007 02 28 11 31 07 2007 02 28 11 31 08 2007 02 28 11 31 09 2007 02 28 11 36 26 2007 02 28 12 00 51 2007 02 28 12 00 51 Device ID 1334 1334 1334 1334 1334 1334 1334 1334 Copyright 2007 by Suprema Inc Event Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Identify Mode Delete Success Delete Success T amp amp A Event User ID 2 3 853 861 934 User Name Source a BioStation BioStation Dongsuk Suh BioStation Nakwon Lee BioStation ChangGyun Lee BioStation BioStation BioStation BioStation http www supremainc com BioAdmin User Manual
78. A Track II In that case the output signal will be in ABA Track Il format You can also specify the number of characters for ABA Track II output Wiegand Configuration ABA Track II Wiegand Format O Pass Through Wiegand Format Custom Wiegand Format C Use ABA Track II 26 bit standard The 26 bit standard format is most widely used and consists of 8 bit FC code and 16 bit ID You cannot change the bit definition and the parity bits in 26 bit standard format Pass Through format Pass Through format is used when only the format of ID field is known When the Wiegand input string is detected BioEntry device extracts ID bits and starts verification with the ID If the verification succeeds the device outputs the Wiegand input string as unchanged Parity check and advanced options are ignored in this format By definition Pass Through format is only useful when the operation mode is 1 1 If the mode is 1 N the bits other than ID field are set to 0 For example assume that 32 bit Pass Through format is composed as follows III X XXXIII WIIN left most bit is Oth bit BITO I Id field X Unknown field You can configure this format in the following sequences Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 219 Wiegand Configuration Format Total Bits 32 pn 26 J Format e CEET KEENT e Deen e TERERERKERERERT a even ay aSlEHEHEHE ER PTD 47 9 odd Parity s GRD
79. BioAdmin Manual Version 4 2 BioAdmin BioEntry BEACon and BioStation are registered as trademarks of Suprema Inc All rights reserved No part of this work covered by the copyright hereon may be reproduced or copied by any means graphics electronic or mechanical methods including photocopying recording taping or information and retrieval systems without written permission of Suprema Inc Any software furnished under a license may be used or copied only in accordance with its terms Suprema Inc reserves the right to modify or revise all or any part of this document without notice and shall not be responsible for any loss cost or damage including consequential damage caused by reliance on these materials Ses SUPREMA Copyright 2007 by Suprema Inc BioAdmin User Manual 2 Suprema Warranty Policy Suprema warrants to buyer subject to the limitations set forth below that each product shall operate in substantial accordance with the published specifications for such product for a period of one 1 year from the date of shipment of the products Warranty Period If buyer notifies Suprema in writing within the Warranty Period of any defects covered by this warranty Suprema shall at its option repair or replace the defective product which is retumed to Suprema within Warranty Period freight and insurance prepaid by buyer Such repair or replacement shall be Suprema s exclusive remedy
80. BioAdmin software met lloton EEN 44 Les erer Eet 47 LAT CONNECE SEINE ere ai ea ian diana aia dana 47 1 5 2 Registering the initial system administrator account EEN 47 19 3 gt Login to the el E EE 48 L User Level on BIOAGIMIN d eucergkeeststbrueEuketeER SEENEN NEESEEEEREEAEEEEGn 49 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 7 1 7 Bertolt Ce 49 1 441 Command Menu Dar neniani a a eaten eae 50 UR E nu TEE 51 Re tel 51 ETA MEIER EE AE EE EE AE 51 8 User DAA cascade crete feet auton aaa Aaaa a aAa aar adins 51 GR Te EE 52 2 1 Quick start with Petten eecht a ene a eee 52 211 Step 1i AW melen 3 hee ee ddd aad ed eat ela di aie 52 2 1 2 Step 2 Search MEW Ee 52 21 3 slep Ee Nee 56 21A Step k User Managements E 60 2 1 5 Step 5 Rules on user T amp A event control eeeccececeseseeeeeeeeeeeeeseesceesceeacseatseataeeeatesaeetseesees 69 2 1 6 Step 6 Enroll user with transfer checked user to device mem 69 ZET Step T Monitoring ENEE EE cies EE aes ected 70 2 1 8 Step 8 Log List ed 71 E We KE Me TEE 71 2 2 Quick start with BioEntry PluS an telsteedelianes Gees dale Gade Ruled eel 72 2 2 1 Step 1 Hardware Installation AAA 72 2 2 2 Step 2 Search a NEW Device snennsenssneenseeesrtenttnrsstenntnttsneenrnnentennnnnonntnnnnnnontennannennn nnn teen 72 2 2 3 Step 3 Connect a New Dewce A 73 2 2 4 Step 4 User Management AEN 74 2 2 5 Step 5
81. Checkbox 2 Ip Addr A Memorial Day Married Car Number 3 Number 4 Date 3 O Date 4 C Checkbox 3 C Checkbox 4 After entering the user information press the OK button After filling out the custom fields the following pop up window will appear On this window you can see the details of your selected custom fields Press OK button to save these custom fields After entering the user information press the Fingerprint tab to enroll user s fingerprint templates Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 93 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 1 1 Security Level BioStation BioEntry Plus Device ID 42965 New BioEntry Wiegand Card ID Setup Device Default sei BioEnty Smart Pass 1st Template 2nd Template D evice Default Duress Duress Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Read Card Write Card Format Card Delete Scar Verification Test Acquire first template by pressing the Scan button followed by touching finger on the USB fingerprint scanner twice Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custo
82. Cl Use Fingerprint Template Encryption Check on the Use Fingerprint Template Encryption Ifyou select the encryption option a warning message will appear If you want to continue the encryption press Yes button BioAdmin Software Press Change Encryption Key button Security Option Change Encryption Key Enter Encryption Key Change Encryption Key New Encryption Key Confirm Encryption Key Press Change button in Change Encryption Key window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 277 Press OK button in Preference window If you press Cancel button in Preference window or if the data encryption is interrupted by a network error system will return to its earlier status before encryption Whenever you change the encryption key you need to apply the new encryption key for each of the connected BioStation Also you need to do so whenever you add a new BioStation to the network Because encryption process will remove the existing user s templates on BioStation you need to transfer the user s templates to the BioStation after finishing the encryption When you use the encryption function It is highly recommended to change the encryption key Encryption key should be less than 31 digits Ifthe encryption is interrupted by a network error or by power failure restart the BioAdmin program Then BioAdmin will automatically transfer
83. Control Device Management Device Configuration Task Device Info Di i 3 y erdi Device Device Name 1058 New BioEntry Plus Device ID 1058 Bi Add New BEACon VE D W Remove Device Device Type BioEntry Plus Firmware Version 1 0_071009 YQ Check Status Ei Refresh Device List etwork Card ID Command Refresh e E All Devices 001 46680495 Issue Card BioAdmin Server 192 168 1 87 Lg Let New BioEntry Plus Gan E 5238 New Biostation Apply to Others Operation Mode Network Setting Entrance limit Setting Door Setting I O Setting Command Card Wiegand Card ID 0 Read Card Command Type Issue Card Add Need Authentication by Administrator W Suprema Inc Command Card has outstanding feature provided by BioEntry Plus which easily add or delete new user or delete all user using BioEntry Plus device Card List Display the list of command card registered to the currently selected BioEntyr Plus Card ID Display the card number read from a card or input the ID of RF card to register Read Card Read the ID of RF card to register and display card ID item Command type Select a function to give the RF card to input Need Authentication by Administrator As it requires a user for admin authentication it may prevent misuse or abuse 4 7 9 Wiegand Wiegand tab is used to manage the Wiegand I O format If selecting the menu W
84. Control ine Set T amp 4 Rule Group Selection Tool Check All Se Device Management SC SmartCard Ss Access Control E Log List Q Monitoring Reports Total User 0 W Suprema Inc Click Add New User to register new user Type user information in the tab of User Data Information Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information 75 User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information User ID Name Company Department Title Details Edit Private Information Access Group Phone Status Active Mobile Group 1 Full Access E Mail Gender Group 2 None Group 3 None Date of Birth 10 17 2007 Group 4 None Stat Dale 1 1 1970 ExpiyDate 12 31 2030 e 0 Other Information Entrance Limitation BioStation Daily Limit 0 0 00 23 59 Timed APB 0 Minute Password BST Admin Leve Normal User You can select your department amp title using combo box To add new company department or title information press J button or type company department title in information input window To save added information press Close button Company Name Your Company Suprema Copyright 2007 by Suprema Inc http www supremai
85. Delete All Delete All Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success System Started System Started Delete All Identify Fail Identify Fail System Started 8 1 Configuration of Log check page TARA Event The Reports page is composed of 2 components Log List User ID User Name 2 3 Dongsuk Suh Nakwon Lee ChangGyun Lee Dongsuk Suh Nakwon Lee ChangGyun Lee Dongsuk Suh Nakwon Lee ChangGyun Lee Dongsuk Suh Nakwon Lee ChangGyun Lee Source BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation Suprema Inc 250 v Log database is stored on host PC enabling to preserve old log data Log list shows stored log events describing Date Time Device ID Event User ID User Name and Source Filtering Tool You can filter log records by Date Device User ID Name Event and Source For example if a device is selected log events of the selected device will be Copyright 2007 by Suprema Inc http www supremainc com BioAdmin U
86. E i A Leger N A A Ge ef A e e fe of A Za ef oeee ei LP AL LGC ae e LLLL SL ALS foo e LAA A a a fff K i i Eales fad E E TN A A ier ee teg Al af wel af eiert ef ra ri fe fe Templates can be enrolled by two methods Enrollment using PC USB scanner 122 1 1 Security Level BioStation BioEntry Plus Device Default BioEntry Smart Pass Device Default x Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Enrollment using BioEntry device connected to host PC By default USB scanner is used for enrollment By enabling the Use BioEntry as Enroll Station check box and selecting a device ID BioEntry device is used to get user s templates Up to 2 fingerprint templates can be included in the user database Acquisition of template Press the Scan button and touch the same finger twice If the acquisition of template is successful scanned template is depicted on the template window To register the second template for different finger press the Scan button at the right section Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 123 Enrollment of duress finger Duress finger can be enrolled to generate duress signal when the specified finger is detected on the device After a template is acquired enable the Duress check box to indicate that the template should be saved as
87. ED Beep sound Setting There are two LED s and one beep on BioEntry device to provide processing status and result to users The colors of two LED s are mixed to generate 3 colors green red and amber By selecting the LED Beep Setting tab the LED Beep configuration page is updated on the main window System Setting UO Setting LED Beep Wiegand Setting I Card Configuration Green LED Disabled Event Enabled Event Delay ms 0 i Enroll ait Finger Enroll Processing Mighms 500 Identify Fail Enroll Success Lois 500 Delete Fail verify Wait Finger Tarmnor Qwittrh On Mi Vorifv Praroccina Mi Count 0 Red LED Disabled Event Enabled Event Delay ms 0 Enroll Success a Enroll Wait Finger a Verify Success a Enroll Processing High ms 1 Identify Success Enroll Fail Low rms 0 Delete Success Verify Wait Finger Vorify Mirrace Mi tvari Praroccina vi Count 1 Beep Disabled Event Enabled Event Delay ms 0 Enroll Wait Finger a Enroll Success a S Enroll Processing Enroll Fail High ms 10 Verify Wait Finger Verify Success Lowims 0 Verify Processing Verify Fail Idontifv Wait Finnar Mi Idontifiv Ciuireoce D i Count 1 Apply Apply to Others Set to Default Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 216 Configuration of LED Beep Programming s
88. Entry Plus and press Search button e e If detected BioEntry Plus press OK button Select the detected BioEntry Plus and press OK button again Note BioEntry Plus supports DHCP function so you can easily verify assigned IP address in your network which can also distinguished as its own device ID In case of static IP network environment you can type your own Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 74 static IP address For more than two static IP address you have to register each one separately After finishing registration you need to type it at the network tab of the corresponding device 2 2 4 Step 4 User Management If clicking User Management menu you can see User Management at the Main Window Note User Data Information mainly devides by User Information and Fingerprint User Information is consists of User ID Name Company Department Title and Phone number Fingerprint is mainly for fingerprint information of user BioAdmin Software System User Management Device Management Access Control T User ID User Name Company Department Title Template Num Active ER Add New User There are no items to show ER Delete Checked Users BS Transfer checked users to device Delete Checked Users from Device ine Manage Users in Device Pil Synchronize Al Users Gy Export to File By Import From File Sa Set Access
89. Grant Device 1 Grant Device 2 Deny Device 1 3 ER Lil Deny Device 2 Duress Device 1 gt Duress Device 2 Tamner Device 1 4 9 4 Switch Setting On this menu you can change the switch setting of BEACon The switch setting can be differently configured depending on the operation mode of BEACon On 1 door mode switch 1 is automatically set up as the door sensor and 3 as RTE request to exit Therefore you can set up switch 2 4 5 and 6 as other various functions on the Normal Switch Setting menu On 2 door mode switch 1 and 2 are automatically set up for the door sensor Also switch 3 and 4 are automatically set up for RTE Therefore you can set up switch 5 and 6 for other various functions on the Normal Switch Setting menu Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual BEACon Relay Setting BEACon Switch Setting Switch 1 v Door 1 Status Setting Switch Select Lock Delay 2000 ms Held Open Delay 10000 ms Not Use Not Use 228 Switch Type NIC D Select a switch to set up the configuration Once you select a switch applicable items for the selected switch will be activated on the switch setting window Switch Select Switch 1 v Door Status Setting Switch Type Nic v By selecting a door sensor switch you can set up the lock delay and held open delay of the connected BEACon If the
90. Inc http www supremainc com BioAdmin User Manual 4 7 5 Emergency Operation Setting Device Input Port Switch Type Duration ms Output Port Hight ms Low ms Count Input 0 Hi 0 Output 0 0 D 0 Save Entrance Limit Setting BioAdmin Software 4 System User Management Device Management Access Control Device Management Task Device Configuration g Search Device S Add New BEACon W Remove Device W Check Status Refresh Device List Device Info Device Name Device Type BioEntry Plus 1058 New BioEntry Plus Device ID 1058 Firmware Version 1 0_071009 Operation Mode Network Setting Entrance limit Setting Door Setting I O Setting Command Card Wiegand pS SS Ss Entrance Limit Setting CH All Devices BioAdmin Server Gg 192 168 1 87 ZE 1058 New BioEntry Plus a F com W 5238 New BioStation Timed APB min Option 1 Option 2 Option 3 Option 4 Automatic T amp A Mode Change T amp A Mode Not Use Default Access Group Setting Default Group Full Access Max Number of Entrance Max Number of Entrance Max Number of Entrance Max Number of Entrance Fixed Entrance Fixed Exit Time Nev Refresh Apply to Others Set to Default Entrance Limit Setting Copyright 2007 by
91. Individual Repor Individual Sun Update Report ae CO Rebuild ai SE View Report 10 1 2007 v 10 31 2007 vi Export CSV file Press upload log and import the latest log information This process is to create a report based on the latest event logs so even after completing upload log log is not displayed on report list Copyright 2007 by Suprema Inc Select company dept and user on setting filtering menu to creating a report Choose either daily report or individual report on type menu Choose start date and finish date of report on period menu Press update report button http www supremainc com BioAdmin User Manual BioAdmin Software System User Management Device Management Access Control Task ine Setup Attendance Rule BR Setup Monthly Schedule G Rule Group Setup a Report List Filtering Company Department UserID User Name Date D 7 Depart Date 10 1 2007 10 1 2007 853 R amp D B Date 10 2 2007 10 2 2007 853 LJ Date 10 3 2007 Title Manager Manager Report Type Daily Report O Individual Repo O Ete Period Im um ei 10 31 2007 ei 267 Upload Log O Daily Summary S O Individual Sun Update Report Refresh Rebuild All View Report Export CSV file User Na In Dongsu Dongsu out Work Over Result Check Check Absence Absence 10 3 2007 853 5 Date 10 4
92. LY e e EEEEEE HATTEN e Press the buttons used to calculate the first parity bit In the example they are BIT1 BIT22 Press gt gt button Press the buttons used to calculate the second parity bit In the example they are BIT23 BIT42 Press Next button Replaced value In 26 bit standard it is possible to specify another FC code In customized format it is possible to specify the replaced value in non ID field If the replaced value is set the device change the fields with the replaced values Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 207 4 8 Manage BioEntry device By selecting a BioEntry on the Device tree the Device Configuration window for the selected BioEntry is updated on the main window BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info 0 Search Device GB Add New BEACon BH Remove Device Device Name 42965 New BioEntry Firmware Version P1 7F 07020500 W Check Status EEN Refresh Device List System Setting I O Setting LED Beep Wiegand Setting Card Configuration Device Type BioEntry Pass TC Serial Number 952965 Operation Mode Both v Baudrate AEN Jetwork e All Devices H L BioAdmin Server 5238 New BioStation 2686 New BioStation d BE 192 168 1 87 Scan Timeout 10 sect o Sensitivity 7 Highest v 1058 New BioE
93. Name Company Department Details Edit Private Information Phone Mobile E Mail Gender Male Date of Bith 10 16 2007 Start Date 12 141970 Expiry Date 12 31 2030 e Other Information Password Access Group Status Group 1 Group 2 Group 3 Group 4 Entrance Limitation BioStation Daily Limit Timed APB Active Full Access None None None 0 00 23 59 Minute BST Admin Leve Normal User Click user information tab and enter user information Copyright 2007 by Suprema Inc 61 http www supremainc com BioAdmin User Manual 62 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information User ID Es W I Edit Private Information Name Dongsuk Suh Company Suprema Department R amp D Title Manager Details Access Group Phone UI 2 345 6789 i Status Active Mobile 098 765 4321 Group1 Full Access E Mail dsuck anymail Group 2 Gender Male Group 3 Date of Birth 6 14 1970 Group 4 Start Date 1 1 1970 Entrance Limitation BioStation Expiry Date 12 31 2030 e h Daily Limit H _ 0 00 23 59 Timed APB 0 Minute Other Information Password BST Admin Leve Normal Use
94. Preferences Preferences menu supports the following functions Device Time Setting Automatic Locking Backup Options Security Option Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Preference Device Time Setting Automatic Locking C Lock all BioEntry readers when exit BioAdmin Backup Options Default Backup Directory Automatic Backup Option C Use Automatic Backup Change Lock Password Security Option O Use Fingerprint Template Encryption Access Control Option Device Time Setting 273 By checking synchronize with current PC time at startup on preference window administrator can set time of linked all devices by host PC time Automatic Locking BioEntry and BioStation can be locked by password to enhance the security If the locked BioEntry or BioStation is found on the network BioAdmin software requests to enter password to unlock BioEntry and BioStation Locking mechanism is enabled by the Lock all BioEntry devices on exit check box in this window or the Lock All Devices menu below the System menu in Command menu bar If it is enabled BioAdmin software locks the devices at termination of the program The Change Lock Password button initiates the Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 274 password management window Lock password of BioEntry and BioStation can be changed by pressing chang
95. Q Refresh Device List l 1 S ES J 2 I i Input SC Device v Por Input 0 e All Devices Oo BioAdmin Server Function Not Use v Switch Type N O E 192 168 1 87 S 1058 New BioEntry Plus Schedule Always v Duration ms 0 o E COM D 5238 New Biostation Tamper Not Use Output Device n058 v Port Relay 0 Alarm On Event Alarm Off Event Delay ms 0 Priority 0 High ms 0 Low ms 0 Count 0 Priority O Refresh Anny Applyto others 1 Setto Default Suprema Inc Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Input Device Function Schedule Tamper Output Output Device v Port Not Use v Switch Type Always Duration ms Not Use Device Type Display the device to be set at present Tamper Set to designate the function of tamper 1058 sl Port Alarm On Event CH Delzwirmc High ms 0 Low ms 0 Count 0 Priority 0 Alarm Off Event 200 Input 0 v N O v 0 Function Select a function to be performed as an input Schedule Set the input to be operated only for the time set in access control Port Select an input terminal set in the selected device Switch Type N O or N C Duration ms Operate as long as the longer time
96. Resource File choose from English Korean Custom no change Select language to change click browse and choose applicable configuration file rc after changing configuration file reset BioStation to apply and select applicable language on language select menu to view Private Msg Select private information such as photo or message displayed in BioStation LCD window Background Choose from logo notice and slideshow as background of BioStation LCD display Volume to adjust speaker volume of BioStation Volume ranges from 0 to 100 When using daily in normal situation set a volume as 20 50 Default is 20 Msg Timeout When a user matches his fingerprint BioStation shows the success or fail message on its screen Administrator can change the time during which those messages are shown on the BioStation Default is set as 2 seconds Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 177 If there s company notice administrator can show the notice on LCD of BioStation Notice can be input up to maximum 1024 byte and a number of letters varies depending on language After transferring notice to device by pressing apply button you can check and view notice on LCD of BioStation only if you selected notice as background in display sound menu and apply BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info
97. SGL OpenSSL Path C OpenSSL bin openssl exe Pass Phrase eeecceee Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 39 BioAdmin Server Config Status e 3ioAdmin Server 4 2 192 168 1 120 Running Connection T TCP Port 1480 Max Connection Database u Database Type MySQL v SaL Connection String Provider MSDASOL 1 Password testtest Persist Security Info Treu User ID bioadmin D ata Source BioddminMySOL OpenSSL Path C Open3SL bin openssLexe Pass Phrase eecccece If the status is changed as Start press OK button Using SQL Server database If you are already using MySQL Server you can use SQL Server database instead of mdb Execute BioAdmin Server Config menu Click the Configure button on the Database field On the Data Link Properties window select Microsoft OLE DB Provider for SQL Server and press Next button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual E Data Link Properties Provider Connection Advanced All 40 Select the data you want to connect to OLE DB Provider s MediaCatalogDB OLE DB Provider MediaCatalogMergedDB OLE DB Provider MediaCatalogwebDB OLE DB Provider Microsoft ISAM 1 1 OLE DB Provider Microsoft Jet 4 0 OLE DB Provider Microsoft OLE DB Provider For Data Mining Services Microsoft OLE DB Pro
98. Server Microsoft OLE DB Simple Provider MSDataShape OLE DB Provider for Microsoft Directory Services Press Next button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 26 Data Link Properties ll R i Provider Connection Advanced All Specify the following to connect to Access data 1 Select or enter a database name 2 Enter information to log on to the database User name Admin Password Blank password C Allow saving password Test Connection Select the Database file and press OK button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 27 Select Access Database Look in E BioAdmin Server My Recent Documents Desktop My Documents Bi My Computer a File name BioAdminData My Network Files of type Microsoft Access Databases mdb d SSL Set up the encryption details between BioAdmin Server and BioAdmin Client or between BioAdmin Server and BioStation Press Refresh button to show the current setting Press Apply button to store the new setting To apply the changes you should stop and restart the BioAdmin Server Press OK button to store the new setting and close the BioAdmin Server Config window Press Cancel button to cancel the new setting and close the BioAdmin Server Config window OpenSSL Setting BioAdmin Serve
99. Software Reset initiate software reset Program sample for input port lf administrator wants to connect the wiegand input of the user ID to the input button to initialize enrollment the following procedure is required Suppose to use input port 0 user should press a button for at least 500 ms to activate a function First choose applicable device on device list window Choose a function of input port 0 with Enroll by Wiegand ID Input 500 as minimum input time of input port 0 Press apply button to transfer new settings to applicable device Configuration of output port In configuring output port multiple functions can be programmed to produce different output pattern on each event Event means when to activate the output port and output pattern defines how to activate the output port respectively Programming procedure is as follows Enable required event by selecting event from disabled event Program output pattern by editing delay high low and count values Output events Event Description when to activate the output port Enroll Success When a user is successfully enrolled on the device Enroll Fail When enrollment fails Identify Success When identification is successfully done Identify Fail When the device fails to find out the matched user Copyright 2007 by Suprema Inc http www supremainc com 213 BioAdmin User Manual Verify
100. User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 65 Device ID 2686 New BioStation Wiegand Card ID Setup 1st Template C Duress x SN RLG CU SNE AAA EE RN Bae fff A fete ei ei ei d eA E Dr D Dr DD Dr D Dr D ae Dr Dr Dr Dr N Cen D n NN E Seeerei e Se ee ae De N N Liebe e Dr Dr D D gg NN Oe en EES SE A aerer ar AA pote LLR AED NN a ae A decal el atl er LE La rr 2nd Template C Duress y wN aN RB y n mmn Ar ta oe F ei REET erer H Set ZZ d d Ae eieiei eieiei ee d Da ig Leger N A A if KEE at ad A tn en A d date SAS ei E Eales ff E PE AA wegen af eer e eier e a On a A LAARA fe fe Delete 1 1 Security Level BioStation BioEntry Plus mp evice Default v BioEntry Smart Pass Device Default v Smart Card AF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Read Card Write Card Format Card How to enter fingerprint information by BioStation device is as follows Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 66 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule 1 1 Security Level BioStation BioEntry Plus Device ID EALEN Tela k
101. User Time Attendance Rule AA 82 2 2 6 Step 6 User registration with Transfer Checked Users to Device mem 83 E RL Ve ul BEE 84 22 8 Step 8 LOG LIB EE 86 2 2 9 2 Sep Ge REDOMS EE 87 2 3 Quick start with BioEntry Smart EE 87 2 3 1 Step 1 Hardware mstbalonon nenn 87 WAT Step 2 Enroll USE iiun iad are iia neler d a ia aeta EN 88 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 8 2 3 3 Step 3 Issuing user smart card EE 95 2 3 4 Step 4 Enroll user ID in the external conter 97 2 3 5 Step 5 Authentication Test 97 2 4 Quick start with BioEntry E 98 2 4 1 Step 1 Hardware instalation e a aaa 98 24 2 Step 2 Search new dewice ANEREN 98 243 Step re EE 101 2 4 4 Step 4 Enroll user with transfer checked user to device men 109 2 4 5 Step 5 Enroll user ID in the external conter 111 2 4 6 Step 6 Authentication Test 111 241 Step T MOning 2 2 02 elites aie aia adi a ead Ahad ania ead 111 248 Step8 Check 10g eier 112 GE e LEE 113 3 1 Configuration of User management PAGE ee eeeeeeeecececeteteeeeeeeeeeeeeeeeeeeeeeteeeeteteteeeeas 113 3 2 SRI le EE 114 33 Usertist Display dl e EE 114 E DOIG E 117 3 5 Add Be EE EE 117 3 91 ler wort eege Zeck Zeeche ebe 118 Kee ue RE A aiid ele dea RATAR 120 3 93 57 e TUE 121 KE ISSUE USEF SMA ME 124 3 5 5 Issue with PC USB smart Card device EEN 124 3 5 6 Issue with BioEntry Smart d dowels 125 3 5 7 User securi
102. access group and security level is transferred by this process Check the registered user to transfer http www supremainc com BioAdmin User Manual 110 User Management rs User ID User Name Company Department Title Template Num Active 853 Dongsuk Suh Suprema R amp D Manager 2 V Select the Transfer Checked Users to Device button and select the devices to transfer the user data Select a Device Me A Devices MB BioAdmin Server MINE 1334 New BioStation Me 192 169 1 254 MEG 254 New BEACon MS 943 New BioEntry ME 1050 New BioEntry Me 192 168 1 74 KR 1539 New BioStation C Overwirte users with different information Select the Manage Users in Device button to see the user list enrolled in the selected device If the color of user data is yellow it means the user data has been successfully transferred to the device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 111 Select Target Device Device List Template Information All Devices UserID Number ofT Access Grou Security Level Check QB BioAdmin Server SE 1334 New BioStation E 192 168 1 254 B 254 New BEACon E 943 New BioEntry 1050 New BioEntry F 192 168 1 74 SC 1539 New BioStation Check All Uncheck All Check Reverse Delete Selected Users Check Same Users Check Diferent Users Check Hen User Delete All Users e Hide
103. ad Card Write Card Format Card Delete Scat Verification Test Acquire first template by pressing the Scan button followed by touching a finger on the USB fingerprint scanner twice Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 108 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enrall Station 1 1 Security Level BioStation BioEntry Plus Device ID 2686 New BioStation Wiegand Card ID Setup Device Defaut ze BioEntry Smart Pass 1st Template 2nd Template Device Default w C Duress Duress Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 i rd N Q NI A MA EE RN Bad PERRE et a a a ae PA E Gen Dn Da YAN E 8 Da xn Ta nx px a att eet ff fff ei ee ee D D D N C Bypass Card NN a D SS li td SSN ON Oe en A ag RE SE Read Card A Ate a ae LEE OL eA dence al al er ff AA E or Write Card Format Card Acquire second template similarly to the acquisition of first template Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 2 4 4 Copyright 2007 by Suprema Inc 109 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule 1 1 1 Security Le
104. age is divided into 3 sectors Device configuration The configuration set up window shows the current configurations of networked BioEntry BioStation and BEACon Also this window shows the configurations to be changed Task box The Task box includes buttons to control basic operations of the Device Management page List Window List Window divides into Device List and Zone List Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 138 Device List displays a list of connected devices and it can be changed its setting value by selecting a certain device Zone List displays the defined zone of the connected device Please refer to 4 4 List Window section for further information 4 1 Search New device To search new BioStation BioEntry or BioEntry Plus device and add click search device menu in task box If add new device window pops up select a device for search from BioEntry BioEntry Plus or BioStation and select serial port TCP IP Ethernet or USB device according to interface between device and host PC The USB connection is available only with BioStation and UDP can be used for BioEntry Plus 4 1 1 Serial port In case device and host PC are linked by serial network set applicable COM port of host PC and select baudrate Default baudrate of BioStation BioEntry and BEACon is 115 200 bps Copyright 2007 by Suprema Inc http www supremainc com BioAdmin
105. and input string is detected the device checks the parity bit first of ally If every parity bit is correct the device extracts ID bit and starts the authentication with the ID A user may set each field with other values and set advanced option such as Fail ID If authentication is successful the output strings may differ from input string depending on replaced values and advanced options Assuming that 44 bit customized format is structured as follows EAAAAAAA III HI BBBBBBBI WII IO the very left bit is Oth bit BITO E Even parity for BIT1 BIT22 O Odd parity for BIT23 BIT42 ID bits Field1 and Field 3 A Field 0 B Field 2 The format may be set as the following sequence Wiegand Configuration Format Total Format Bits 44 ID Bits 0 e fi DI 15 i UserID 16 fife fee DI 31 Even Parity 2 EMEEN E 48 OERE 47 0 dd Parity Hi 63 Undefined PARAR Copyright 2007 by Enter 44 into Total Bits field Select Even Parity Press even parity bit In the example it means BITO According to the definition repeat 2 and 3 for Odd Parity and User ID Press Next button Suprema Inc http www supremainc com BioAdmin User Manual 206 Wiegand Configuration Parity Choose bits for calculating parity 1 2 FETT PERERPER s Co STMT OMe ITT a Da 32 AE ee
106. anual 136 Importing lt Back JI Finish 1 Cancel Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 137 4 Device Management By selecting the Device Management menu the device management page is updated on the main window Task Box Device Configuration Bic Admin Software Dev ce Management Device Contiguration Task a Device Info Search Device Device Name 1058 New BioEntryPlus Device ID 1058 E Add New BEACon r BH Remove Device Device Type BioEntry Plus Firmware Version 1 0_071009 Check Status Ke Operation Mode Network Setting Entrance limit Setting Door Setting I O Setting Command Card Wiegand Q Refresh Device List BioEntry Plus Time nod 0 18 2007 Sync with Host PC Time All Devices z BioAdmin 5 ii g EE Time 8 19 29 PM E GetTime 1 SetTime 1058 New BioEntry Plus a E com 5238 New BioStation Basic Setting Operation Mode Setting All Always x Double Verification Mode Card Fingerprint No Time KA Double Verification Mode Only Card No Time K i Double Verification Mode Fingerprint No Time v Double Verification Made d Fingerprint Setting Security Level Normal 1 N Fast Mode Auto Scan Timeout 10 Matching Timeout 3 Refresh Apply to Others Set to Default Wa Suprema Inc Device amp Zone List Device management p
107. ata loss from the virtual terminal Delete All Device From USB Memory Remove the data of all virtual terminals from the USB memory To use the USB memory again as a virtual terminal you need to register the USB memory as a virtual terminal Delete Device from USB Memory Remove the data of the selected virtual terminal from the USB memory BioStation Tii All Devices BioAdmin Server Le d Check Status S 192 168 1254 Cp New BEACor Safely Remove USB Memory E 42965 Refresh Virtual Devices l 42714 Delete All Device from USB Memory u Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual i Bio All Devices D BioAdmin Server EI Virtual USB Device E Ti Check Status a 192 168 BB Newt Safely Remove USB Memory lt E d Delete Device from USB Memory i re IC 4 4 List Window List Window divides into Device List and Zone List 149 Device List displays a list of connected devices as Icon type and Zone List displays the defined zone of the connected device 4 4 1 Device List if Device List is connected icon is active e 192 168 1 77 SE 5238 New BioStation E gt Virtual USB Device E T 2686 virtual BioStation B 192 168 1 254 E New BEACon 42965 New BioEntry 42714 New BioEntry If Device List is not connected icon is inactive Copyright 2007 by Suprema Inc http www supremainc com BioAdmin
108. ate New Zone and click it E ee Il Zones A CO Stand Alone d 2686 New BioStation Type Zone Name as you want and select a device as Master Device Check a mark a device to be Zone Member and press Next button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 152 Zone Management Zone Name New Device Group Master Device 5238 New BioStation Zone Member rat 058 New BioEntry Plus 2686 New BioStation You can select synchronization what you want among same zone device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 153 Zone Management Syne Option Setting Synchronize User Info Synchronize Log Data Select Sub Zone whether it is APB Entrance Limit or No Sub Zone Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 154 Zone Management Sub zone Management Create New Anti passback Zone Create New Entrance Limit Zone Modify Existing Sub zone No Zone Name Zone Type Zone Men For the purpose of synchronization only within same zone device please select Not use Sub Zone Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Zone Management Created New Zone Press Finish to transfer data to each device Zone Information Zone Name New Device Group Master 5238 New BioS tati
109. ated and stored on the host PC Then it is selectively distributed to the BioEntry and BioStation connected on the network using transfer menu Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 17 1 2 8 Transfer Transfer to Device is used to transfer the user database of the host PC to BioEntry and BioStation The user information such as User ID templates access group and security level is transferred by this process Detailed operations are as follows Enroll new users on BioEntry and BioStation Replace inconsistent templates on BioEntry and BioStation Delete templates of unknown users or de selected users on BioEntry and BioStation Transfer from Device is used to upload the user formation from BioEntry and BioStation to the database of host PC The user information such as User ID Template Number Number of Access Group and Security Level can be uploaded by this process 1 2 9 Site key for smartcard Site key is a password for smart card to ensure that an authorized card should be used for a specific installation 48 bit key is used in BioEntry Smart allowing 0 to 281374976710655 OxFFFFFFFFFFFF For proper operation the same key should be configured on BioEntry Smart and user s smart card 1 3 How to place a finger 1 3 1 Select a finger to enroll 1 Itis recommended to use an index finger or a middle finger 2 Thumb ring or little finger is relatively more difficul
110. ated on the main window B BioAdmin Software i System User Management Device Management Access Control Log List is Get Recent Logs Auto Upload Ca Stop Auto Uploading gS Upload All Log fa Export Report E Delete Log Data Status Auto Uploading Off Filtering Tool 21 1 2007 2 28 2007 Device ID UserID Event C Source Date Time 2007 02 28 11 31 05 2007 02 28 11 31 06 2007 02 28 11 31 07 2007 02 28 11 31 08 2007 02 28 11 31 09 2007 02 28 11 36 26 2007 02 28 12 00 51 2007 02 28 12 00 51 2007 02 28 12 00 52 2007 02 28 12 00 52 2007 02 28 12 00 53 2007 02 28 12 00 53 2007 02 28 12 01 05 2007 02 28 12 01 41 2007 02 28 12 01 57 2007 02 28 12 01 58 2007 02 28 12 02 00 2007 02 28 12 02 01 2007 02 28 12 02 02 2007 02 28 12 02 03 2007 02 28 12 02 13 2007 02 28 12 02 14 2007 02 28 12 02 15 2007 02 28 12 02 16 2007 02 28 12 02 17 2007 02 28 12 02 18 2007 02 28 15 37 19 4 2007 02 28 20 23 19 2007 02 28 21 21 05 2007 02 28 22 04 59 2007 02 28 22 05 07 2007 02 28 22 05 41 Device ID 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 1334 Event Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Identify Mode Delete Success Delete Success Delete Success Delete Success Delete Success Delete Success
111. ated on the main window Main window contains the following information and controls Retrieved information from currently selected device Information stored on host PC such as user database or log data Controls to manage or to configure the information User Database User database refers to the entire user information including user ID user name and fingerprint information BioAdmin software is based on user database management in priority That is user database is created updated and saved to host PC Then it is selectively distributed to BioEntry and BloStation devices connected to network via transfer Note Difference between select and check select is used when choosing each user ID in select tool box press Shift button and choose a user with an arrow key or click the last user ID with a mouse to select multiple users whereas check is to check each selected user ID Using check tool you can check all uncheck all reverse check check user and uncheck a selected user with ease Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 52 2 1 Quick start This chapter explains basic procedures of operating BioEntry BioEntry Plus and BioStation device integrated with external system Quick start with BioStation This paragraph describes basic procedures of operating BioStation Step 1 HW installation BioStation can be networked by cable wireless LAN as well as
112. ation check get IP address automatically In case of not using DHCP check set IP address manually and set IP address gateway subnet mask and DNS Changing LAN setting like this is required to set IP address in order to connect Serial or USB linked BioStation by LAN or to change IP address of BioStation connected by LAN to another address Max means the maximum number of host PCs Server Client application is available only when the system is networked through Ethernet If the system operates as server client users can operate the BioAdmin Client program from multiple host PCs However if the system is not operated as BioAdmin Server BioAdmin Client but connected just as normal Ethernet there will be a limit to the maximum number of host PCs to operate BioAdmin at the same time For example if you select this menu as 4 you can operate the BioAdmin program on 4 host PCs at the same time Server Setting This menu shows that the BioStation is connected to the server You can connect the BioStation to the server by checking on Use option and entering the server IP and server port If you connect a BioStation to the server existing Ethernet connection of the BioStation is disconnected and the BioStation is connected to the server It may take a few minutes to reconnect to the server depending on the network Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 168 condition If you check on
113. authorized access Smartcards are encrypted with a 48 bit site key For a BioEntry device to decrypt a Smartcard the site key stored in the device should match with that of the card Users can store as many as two site keys in the BioEntry device and select two advanced options If the Use Secondary Key option is selected the device will try both the primary and secondary keys when decrypting a Smartcard If it is not selected the device will try only the primary key The Auto Update option is useful when changing the keys of Smartcards With this option on the device will re encrypt a Smartcard with the primary key when it is encrypted with the secondary key Note Site keys should be handled with utmost caution If it is revealed the whole system is not secure any more Primary Key PrimaryKey Change Change Primary Key Current Primary Key New Primary Key Retype Primary Key Change Site Key Option C Use Secondary Key C Set current primary site key to secondary key To change the primary key you should enter the current and new primary keys Besides the Auto Update option you can also select the following options Set current primary site key to secondary key Replaces the secondary key with the current primary key before changing the primary key Secondary Key To change the secondary key you should enter the current primary key and the new secondary key Copyright 2007 by Suprema Inc http
114. c com BioAdmin User Manual 270 The result can be modified at the report By clicking Result of the report the list to select displaying result will be shown as above figure which is appeared on bold strokes and verified the changes easily we Result ct lEarly Out r ee In Note After correcting report data you should press Update Report button without checking on Rebuild All If you check on Rebuild All T A data will retum to the original data before such correction Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 271 10 10 1 10 1 1 10 1 2 10 1 3 10 1 4 Menu bar functions System i System User Management Device M Admin Account Backup Database Restore Backup Lock Al Devices Unlock All Devices Load BA ver 1 x Data Preference About BioAdmin Reconnect Server Manage admin account Add administrator to log in the BioAdmin or change password user level of an existing administrator Data backup Make manual backup file as well as auto backup file on the option menu Backup file is saved as date serial number format at the server installed a path Data recovery After BioAdmin software modified to server client type data recovery is possible to copy backup file to server installed PC To recover a data previously created backup file should be existed By coping the
115. c com BioAdmin User Manual 83 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Rule group REMMI AmE v Apply to all user Daily Schedule Sunday New Attencance Code Monday New Attencance Code Tuesday New Attencance Code Wednesday New Attencance Code Thursday New Attencance Code Friday New Attencance Code Saturday New Attencance Code Holiday New Attencance Code Holiday Group Al holiday Monthly Schedule Name New monthly schedule First Week Sun Mon Tue Wed Thu Fri Sat C Working Day Second Week Sun Mon wed Thu Fri Sat C Holiday Third Week Sun Mon Tue Wed Thu Fri Sat Fourth Week Sun Mon Tue wed Thu Fri Sat Fifth Week Sun Mon Tue wed Thu Fri Sat Sixth Week Sun Mon Tue Wed Thu Fri Sat 2 2 6 Step 6 User registration with Transfer Checked Users to Device menu Transfer checked users to device is used for transferring user database from host PC to BioEntry Plus device which are User ID Fingerprint Access Group Admin Level and so on Check registered user User Management bi User ID UserName Company Department Title Template Num Active k 853 Dongsuk Suh Suprema R amp D Manager 2 Click Transfer checked users to device
116. ce Set ng E 171 45 6 moge sS SOUNG ME 175 r SNAN Lee EE 176 4 5 8 WICOANG DEE 177 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 10 4 9 9 Door Seuing a Banas Sedan ana ee Bhan A ee as 182 4 510 O Setting BE 184 4 5 11 Entrance Limit Settings Ee EE 186 46 Manage AKTER vu EEN 188 4 7 Manage BioEntry Plus E E 189 CT Device information inssin AEE EAA AEAEE Aaaa 189 4 7 2 Detect Device via UDP EEN 189 4 7 3 Operation Mode niiin a a ia a n 192 ATA Network Seting iiini iaa EEEE E EE 194 4 7 5 Entrance Lmt Seling ensien RE AE E 196 E DOO SOG E 197 Dee o EE 199 4 7 8 Command Gard osred enint nni tasted saseiiaiaatiaaiala aed hanaeidara ainda 201 ALLS Wiegand DEE 202 4 8 Manage BioEntry device u cccccinue icin dence dea dn 207 4 81 RE RT E TE 207 43 2 SYSIEM E ul WEE 208 48 3 VO SENG E 210 48A LED Beep sound ees dada hed EE 215 4 3 5 Wiegand Seung DEE 217 4 3 6 lt Smart Card Seting isscha seinen tained eal R 222 NR BEACON Ore ue V e gt 4 EE 224 4 9 1 Operation Mode Suche ranned aaa s aa ilar a hulu lia de 225 4 9 2 Signaling speed Baud rate AEN 225 4 9 3 BEACon Relay Seting aurin aaiae ata rAd ORALE AA EEEE REAREA EA 225 AGA Switch Setting EE 227 4 9 5 Refresh Apply Transfer apply to another devce ENEE 229 RE e EE 230 5 1 Configuration of Smartcard Page c cccscecececeeesessscnneeteeseeseseneceenseseneeseeseeeseeees 230 5 2 Smartca
117. check in check out devices can be designated separately using select device menu In that case limited to check in device first time is applied as check in and limited to check out device last time is applied as check out In case user inputs check in or check out for unselected device log information is indicated as check in or check out but when creating a report check in or check out is not applied Using function keys BioStation In case of choosing using function keys BioStation limited to the cases when T amp A key set in BioStation it is applied to a report as check in or check out This menu is applied only to BioStation Therefore BioEntry can t be used as T amp A device in this case Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 260 User can choose a device for T amp A use thru select device menu Select a Device IG All Devices ETS 192 168 1 250 CR 250 New BEACon OE 22547 New BioEntry Me 192 168 1 60 MME 1811 New BioStation Me 192 168 1 27 ig 1539 New BioStation ETS com OE 1050 New BioEntry In case of choosing use all devices to collect attendance data all devices connected to network are used for T amp A device However in case of choosing using function keys BioStation BioEntry can t be used for T amp A device In case of choosing use selected device to collect attendance data only selected device can be used for T amp A device
118. com BioAdmin User Manual 57 You need to designate the port as 1470 Add New Device Search BioEntry Search BioStation Serial Port COM Port h Baudrate TCP IP IP Addr 192 168 f 1470 USB Device BioStation O USB Virtual BioStation Search Searching 192 168 1 74 port 1470 Detected Device New BioStation 1539 Finish Device Search 1 device s found Administrator needs to know IP address and port 1470 Once device is connected properly IP address is displayed as one group and device ID is displayed with a bracket on device tree window Device Tree E Ed All Devices QB BioAdmin Server SE 1334 New BioStation 192 168 1 254 R I 254 New BEACon 943 New BioEntry 1050 New BioEntry 192 168 1 74 SE 1539 New BioStation Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 58 Wireless network setup Set up free set name network name SSID data encryption key type and network key check on wireless network setup before operation Applying DHCP you can set automatic upload of IP address on BioAdmin in order to get IP address automatically check such an IP address and search a device in device management When setting IP address manually you can search a device by specifying assigned IP address gateway and subnet mask BioStation WLAN Setting Preset Name WPA ESSID biostation_wpa
119. cument Except as provided in Suprema s Terms and Conditions of Sale for such products Suprema assumes no liability whatsoever and Suprema disclaims any express or implied warranty relating to sale and or use of Suprema products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Suprema products are not intended for use in medical life saving life sustaining applications or other applications in which the failure of the Suprema product could create a situation where personal injury or death may occur Should Buyer purchase or use Suprema products for any such unintended or unauthorized application Buyer shall indemnify and hold Suprema and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim of personal injury or death associated with such unintended or unauthorized use even if such claim alleges that Suprema was negligent regarding the design or manufacture of the part Suprema reserves the right to make changes to specifications and product descriptions at any time without notice to improve reliability function or design Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined Suprema reserves th
120. d BEACon Switch Setting For the detailed operation of BEACon refer to BEACon operation manual Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 225 4 9 1 4 9 2 4 9 3 Operation Mode BEACon can control up to two doors The Operation Mode window shows whether the selected BEACon is configured as one door mode or two door mode Signaling speed Baud rate The Baud rate window shows the transfer speed of the selected BEACon Baud rate On this menu you can select the transfer speed of BEACon If you change the Baud rate on this menu communication speed between BEACon and host PC will be changed Once you change the Baud rate of BEACon you also need to accord the Baud rate of BioEntry and BioStation with the changed Baud rate of BEACon Operation Mode Baudrate Set One Door Mode SetTwo Doors Mode 115200 v BEACon Relay Setting On this menu you can change the relay setting of BEACon The relay setting can be differently configured depending on the operation mode of BEACon On 1 door mode relay 1 is automatically set up as door release Therefore you can set up relay 2 3 and 4 as alarm On 2 door mode relay 1 and 2 are automatically set up as door release Therefore you can set up relay 3 and 4 as alarm Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 226 BEACon Relay Setting BEACon Switch Setting Relay Selec
121. d ID Setup 1st Template SS RN Bae fff A fete ei ei ei d eA eR RRR NS sae NN gar ae De N N eee e Dr Dr D D gg NN Fh oh a ae PA PB ot CALL foro VW ME 1 SE rs MA E LLR AED C Duress Ee Mr Lea ME fo a tt ff ff ft rr Se e e 2nd Template C Duress y wN aN RB y n mmn Ar ta oe F ei REET erer H Set ZZ d d Ae eieiei eieiei ee d Da ig Leger N A A if KEE at ad A tn en A d date SAS ei E Eales ff E PE AA wegen af eer e eier e a On a A LAARA fe fe Delete The method via BioEntry Plus is following as Copyright 2007 by Suprema Inc 1 1 Security Level BioStation BioEntry Plus mp evice Default v BioEntry Smart Pass Device Default v Smart Card AF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Read Card Write Card Format Card http www supremainc com BioAdmin User Manual 80 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule 1 1 Security Level BioStation B ioEntry Plus Device ID 1058 New BioEntry Plus ze Wiegand Card ID Setup Device Default e BioEntry Smart Pass _ 1st Template 2nd Template Device Default v Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Scan In case
122. d on because it should receive log data from the connected BioStation and store it on the database real time After selecting a PC to use as the BioAdmin Server install the BioAdmin Server program This chapter shows the installation process under the condition that you are using the database on your host PC If you are using MySQL or SQL Server you can refer to the chapter 1 4 3 Start Installation Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 20 Bi BioAdmin Server InstallShield Wizard Welcome to the InstallShield Wizard for BioAdmin Server The Install ard will install B nin on your computer To continue click Next Choose Destination Location BioAdmin Server InstallShield Wizard Choose Destination Location Select folder where setup will install files Setup will install Biaddmin er in the following folder To install to this folder click Next To install to a different folder click Bre and select another folder Choose the hard disk drive on which BioAdmin Server is to be installed By Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 21 default BioAdmin Server is installed in C Program Files BioAdmin Serven Setup Open SSL ie Setup OpenSSL Welcome to the OpenSSL Setup Wizard This will install OpenSSL 0 9 8d on your computer It is recommended that you close all other applications before continuing Cl
123. door is closed the door strike will be locked after your designated lock delay time If the door is opened for more than your designated Held Open Delay time the held open door event will be triggered Door 1 Status Setting 2000 ms Held Open Delay 10000 ms Lock Delay Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 229 4 9 5 Door RTE Setting By selecting RTE switch you can set up the input delay If the RTE switch is activated for more than your designated input delay time the door will be opened Door 1 RTE Setting Input Delay 300 ms Normal Switch Setting For the remaining switches you can set up other various functions such as RTE tamper clear alarm switch If the switch is activated for more than your designated input delay time the selected function will be triggered Normal Switch Setting Function Not Use vi Input Delay 0 ms Refresh Apply Transfer apply to another device Refresh You can restore the original configuration by pressing the Refresh button before pressing Apply button Apply After changing the configuration you need to press the Apply button to save Transfer You can transmit the changed configurations to other devices by pressing the Transfer button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 230 5 Smartcard The Smart Card menu is used to see the list of smartcards issued o
124. duress mode Note What is duress mode Duress finger can be used in a situation when one is threatened by a thief in front of a door If duress finger is entered door is opened normally but it can be set to sound an emergency alarm or ring an emergency call which has been set as output port For instance in case of enrolling 2 fingers the first finger can be enrolled as normal finger whereas the second finger as duress finger Duress finger should be a different finger from a normal finger enrolled beforehand Delete fingerprint To delete fingerprint delete from the second fingerprint information on the right The first fingerprint information can be deleted after the second fingerprint information is deleted Test matching In order to check that enrollment of template is properly completed matching test can be processed Press the Test Matching button and touch the registered finger on the specified device Then a message will appear to show the matching result Wiegand RF ID Set up Wiegand RF ID Device ID 3143 New BioStation Get Wiegand RF ID UserID 853 Use User ID as RF ID wWiegandiRF ID 000 H J Input Wiegandi RF ID manually If you use BioStation RF or use the normal BioStation along with an external Wiegnad card reader you need to allocate the card ID to each user Press this Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 124 3 5 4
125. e Option 4 LI Max Number of Entrance Default Access Group Setting Default Group Full Access v l Refresh Apply to Others Set to Default Suprema Inc Entrance Limit Setting may be set to restrict repetitive verification or prevent repetitive entry for a specified time Timed APB Limit verification if re verification is not attempted for a specified time minute Options 1 4 If entering start time end time of each option and specifying the Max Number of Entrance for the time it allows the only number of access for the specified time Default Access Group Setting In case of a user with no access group information it may set a user to be grouped in an access group The default is Full Access which allow users who does not assign access group Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 188 4 6 Manage Virtual Terminal You can manage a virtual terminal with the same device management menus for BioStation except the followings Time Setting You can not set the time of BioStation with virtual terminal Thus you should set time directly to BioStation Lock all devices Unlock all devices You can not set lock unlock of BioStation with virtual terminal Thus you should the lock unlock directly to BioStation Firmware Upgrade Store a firmware file on a virtual terminal Connect the virtual terminal to BioStation and upgrad
126. e Attendance Rule Use Device as Enroll Station ee Security Level BioStation BioEntry Plus Device ID n 058 New BioEntry Plus ze Wiegand Card ID Setup Device Defaut ze BioEntry Smart Pass 1st Template 2nd Template Device Default e C Duress C Duress Smart Card RF ID Smart Card GAN S N 0 RF 000 0 N Ce D Bi EEE EER ERA E ea a e eegen E e S A arr D NN i KS H ff Be ue E X vA Pai Pa E ECH LASS LA OA ei ae ee f Be i Ce EA e e Se Se E E Lee n D A A 8 User ID UserlD 853 sa ANN E d LB DE E D Din Dn D e 2 AL AS NN A Wd D Dm H e NN M Si Ges urban N N teg EE a EE SEE E an dn D ee sc a a a A aen C Bypass Card ee lf SAPP AS ef bff ef forn Oe a fo wi Read Card SLPS fren FAAS forte RK Write Card Format Card Press Ok button for exit then you can see the registered user data in the User Management window which means that it was recorded in database of host PC User Management e User ID User Name Company Department Title Template Num Active E 853 Dongsuk Suh Suprema R amp D Manager Step 5 User Time Attendance Rule By applying already registered User time attendance rule group to the user it will be used for a reference when generated a report Copyright 2007 by Suprema Inc http www supremain
127. e button and entering old and new password Change Lock Password Change Password Old Password New Password Retype New Password Help Get Challenge Code Unlock Device and Password to Default Note As BioAdmin software doesn t save lock password administrator should remember the password when using lock mechanism Resolving the locked devices If the devices are locked but cannot be unlocked in case of forgetting password the following procedures are required Obtain a challenge code file using the Get Challenge Code button and send the file to technical support team support supremainc com Get Challenge Code Select Device Device ID 1058 New BioEntry w e65ba5fc4a97F Fcd496494b6485b37d6 9618b5f1caeb67534558227Fe76668c6 Click Write to File for writing to file then e mail us with the file The support team will send you the unlock code file corresponding to the Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 275 challenge code Use Unlock a BioEntry and Password to the Default button to resolve the device Then the device is unlocked and password is changed to default null Write Challenge Code Select Device Device ID H Ost New BioEnty v Open Code File e641ccea 1452499627F58c148466F a3 SchafF643F 4a1F 49338 2ad583ek4db57ea Click Write to unlock the BioEntry Backup Options Default backup d
128. e size of image file to upload is different adjust image size using graphic tool In background user can choose and upload one image file as background of logo image and notice As for slideshow maximum 16 image files can be uploaded and it shows images in turn at a set interval Sound In this menu user can change sounds of device or check current sound effects Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 176 Sound effects of device consists of 6 sounds in total i e start sound when device is turned on button sound when pressing a button scan success sound when finger scan is successful question sound when pressing a ESC button error sound when finger scan failed detect finger sound when a finger is placed on fingerprint sensor Note the size of sound file can t exceed 512KB and sounds may not change depending on the format of the file 4 5 7 Notice Display Sound Language choose language used for menu and various messages on BioStation LCD display Language can be chosen from Korean English and Custom Sub Info set items displayed at the lower part of BioStation background Choose from notice time and none In case of notice contents are scrolled from right to left on display Default is time Menu Timeout if no input is made in a certain menu for a set time it returns to initial page Choose from infinite 10 sec 20 sec 30 sec Default is 20 sec
129. e t of 2 If necessary administrator can add or correct user s T A data H you double click a specific T A data on daily report or individual report Edit Data window will be initiated Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Edit Data Event Date 2 1 2006 Name UserID Result Event date Event time Event 7 16 44 4M 2 1 2006 6 57 10 PM Event Property Date This Day Time Event In Device Add Event Edit Event When you change events you must refresh resu Rebuild All 269 Dongsuk Suh Device 5221 New BioSt 5221 New BioSt 7 16 44 AM ZS 5221 New BioStatic v Delete Event It list without checking Ifyou refresh list with Rebuild All all of result data will roll back in selected Close period Enter desired event values on the Event Property box and press Add Event or Edit Event button Press Accept button to apply the corrected data to T A report The changed events are displayed as Result field in grey color RB Date 2 1 2006 2 1 2006 853 Dongsuk Suh 7 16 44 AM 6 57 10 PM 11 40 Date 2 2 2006 2 2 2006 853 Dongsuk Suh 8 17 31 AM 5 07 06 PM 08 49 Copyright 2007 by Suprema Inc Date ID UserName In Out WorkTime OverTime Result Check In Check Out 00 57 In Out 00 00 Late In In Out http www supremain
130. e the firmware using firmware upgrade menu on BioStation After connecting a virtual terminal to BioStation you can use the following menus of BioStation For the detailed operation refer to the BioStation User Guide Synchronize Change the user data and device settings of BioStation as same as the stored data on virtual terminal Export Virtual Terminal Remove the stored data on virtual terminal and make a new virtual terminal with the current data of the BioStation Import Virtual Terminal Remove the stored data on BioStation and apply the data store on virtual terminal Firmware Upgrade Upgrade the BioStation firmware with the stored firmware file on virtual terminal Initialize Remove all virtual terminals on from USB memory Refresh Check the status of the USB memory and activate menus regarding USB memory Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 189 4 7 Manage BioEntry Plus device 4 7 1 Device information H shows the device name device type device ID and firmware version of the selected BioEntry Plus Device ID number and firmware version are necessary information to check the product for our technical support after the installation BioAdmin Software DER System User Management Device Management Access Control Device Management Device Configuration Ge Task Device Info W Search Device GB Add New BEACon BH Remove Dev
131. eans user information has been added to Database in host PC User Management User ID UserName Company Department Title Template Num Active Dongsuk Suh Suprema R amp D Manager 2 t 853 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 2 1 5 Step 5 Rules on user T amp A event control New T amp A rule can be applied by day User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Rule group Apply to auser Daily Schedule Sunday New Attencance Code Monday New Attencance Code Tuesday New Attencance Code Wednesday New Attencance Code Thursday New Attencance Code Friday New Attencance Code Saturday New Attencance Code Holiday New Attencance Code Holiday Group All holiday Monthly Schedule Name New monthly schedule First Week Sun Mon Tue wed Thu Fri Sat Working Day Second Week Sun Mon Tue We Thu Fri Sat Holiday Third Week Sun Mon Tue wed Thu Fri Sat Fourth Week mm Mon Tue wed Thu Fri Sat Fifth Week Sun M ue wed Thu Fri Sat Sixth Week Sun Mon Tue we Thu Fri Sat 2 1 6 Step 6 Enroll user with transfer checked user to device menu Transfer checked user to device is used to transfer user database from host PC to BioStation User information s
132. electing Security Option Preference Device Time Setting Automatic Locking C Lock all BioEntry readers when exit BioAdmin Change Lock Password Backup Options Default Backup Directory Automatic Backup Option Cl Use Automatic Backup Security Option Cl Use Fingerprint Template Encryption Access Control Option In case of changing settings such as various modes changes are applied only after apply button is pressed 4 5 3 Network setting This window shows setup for various networks of a device As per interface Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual methods it is divided into LAN serial and USB LAN 165 In network setup list box at upper part of a window set whether or not to use LAN and if yes whether to use cable LAN or wireless LAN Specify a port as 1470 BioAdmin Software System User Management Device Management Access Control Device Management Task W Search Device Ki Add New BEACon W Remove Device W Check Status Refresh Device List 5 All Devices BioAdmin Server E 192 168 1 87 SS 1058 New BioEntry Plus a F com W 5238 New BioStation WLAN Setting Device Configuration Device Info Device Name Device Type Image amp Sound _Operation Mode fEtnemet v LAN Type WLAN Setting TCP IP Server Setting Serial RS 485 Mode Baudrate Slave Device 5
133. en parity for BIT1 BIT22 O Odd parity for BIT23 BIT42 ID bits Field1 and Field 3 A Field 0 B Field 2 You can configure this format in the following sequences Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 181 Wiegand Configuration Format Total Bits A ID Bits 28 Format co DATATE gt Ouer Enter 44 in the Total Bits field Select Even Parity Press the even parity bit In this example it is BITO Select Odd Parity and press the odd parity bit and User ID according to the definition Press Next Wiegand Configuration Parity Choose bits for calculating parity 1 2 Parities o EPEE ERREPRERE s e RRERERR DR Ces _ a M IKKEEED o oe PITTA BE e Press the bits which are used in calculating the first parity bit In this example they are BIT1 BIT22 Press gt gt Press the bits which are used in calculating the second parity bit In this example they are BIT23 BIT42 Press Next Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 182 Alternative values In 26 bit standard you can specify alternative FC code In Custom format you can specify alternative values for non ID field If alternative values are set the BioEntry device will replace corresponding fields with these values before sending outputs Wiegand Configuration Alternative Value 26 Bit Standard Custom Format F
134. er to Uninstall BioAdmin Server Service Run Install BioAdmin Server Service for restarting Log in to BioAdmin Connect Server Connect Server Server IP Server 1480 Connected to server Enter the server IP and server port Press Test button and check whether the BioAdmin Client can access to the BioAdmin Server Press Save button to store the server setting and access to that server Registering the initial system administrator account Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 48 Register Admin There is no system administrator Register a new system administrator now Admin ID Password Confirm After entering Admin ID and password press OK button At this initial registering you can put any Admin ID and password This initial registration is required to open the BioAdmin Client program after installing the BioAdmin Server Therefore once you register this initial Admin ID and password you can log in to the BioAdmin Client without registering additional admin account from the next time 1 5 3 Log in to the BioAdmin 4 2 LH BioAdmin 4 2 Admin ID Password Connected to server After entering the Admin ID and password press log in button Enter the Admin ID and password you used upon registering the initial administrator account You can see the s
135. ering Report Type ine Setup Attendance Rule BR Setup Monthly Schedule Rule Group Setup Department None O ndividualRepo Individual Sun Company None Daily Report Daily Summary UserID 0 O Ete User Name Period 1o 12007 w mmm ei 257 m Upload Log Update Report Rebuild All View Report Export CSV file Date ID Depart Title User Na In Out fe Result Check Check Date 10 1 2007 10 1 2007 853 R amp D Manager Dongsu Absence B Date 10 2 2007 10 2 2007 853 R amp D Manager Dongsu Absence Date 10 3 2007 10 3 2007 853 R amp D Manager Dongsu Absence B Date 10 4 2007 10 4 2007 853 R amp D Manager Dongsu Date 10 4 2007 Date 10 5 2007 10 5 2007 853 R amp D Manager Dongsu Absence Date 10 6 2007 10 6 2007 853 R amp D Manager Dongsu Absence B Date 10 7 2007 10 7 2007 853 R amp D Manager Dongsu Holiday S Date 10 8 2007 v tnlolonn ops non Mananne me dessen 9 1 Configuration of reports page Report list page consists of 2 elements Report list page a Suprema Inc Report list shows menus setting filtering report type period and basic information required for creating a report Task box Task box has buttons to set T amp A rule Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 258 9 2 Setup attendance rule Press setup attendance
136. ers Check Same Users Check Diferent Users Check New Users Delete All Users S 3 JHide Same Users Users 10 Templates 20 40 Get fram Device Close Detailed operating process is as follows Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 131 Press Manage users in device button Select a corresponding device on device list window Under device list window you can see user and number of fingerprint information enrolled in the selected device User classification Same user user whose user information in BioAdmin software corresponds to user information uploaded from device Different user user whose user information in BioAdmin software doesn t correspond to user information uploaded from device New user user information uploaded from device doesn t exist in BioAdmin software it can be construed as surplus user in device Color classification Same user indicated in yellow Different user indicated in red New user indicated in white Check classification Check all check select all user information Uncheck all to uncheck after checking all user information Check reverse to uncheck checked user or check unchecked user Delete selected user to delete selected user Check same users select users whose user information in BioAdmin software corresponds to user information uploaded from device Check different use
137. erver information by pressing the Server Setting button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 49 1 6 User Level on BioAdmin 4 2 On BioAdmin 4 1 you can differentiate the user level into three groups as below Administrator Administrator can change and see all the settings on BioAdmin software Viewer Viewer can see the settings but can not change any settings on BioAdmin software User User can see his log information 1 7 BioAdmin configuration BioAdmin Software is composed of 4 elements command menu bar main menu task and utilities and main window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 1 7 1 R ElioAdmin Software Command Menu Bar i System User Management Device Management Access Control Sa User Management Task ES Add New User ES Delete Checked Users Sp Transfer checked users to device e Delete Checked Users from Device EC Manage Users in Device en Synchronize All Users cy Export to File E Import from File Selection Tool Uncheck Selected Users Main Menu Task and Utilities Command Menu bar user Management User Name Dongsuk Suh Nakwon Lee ChangGyun Lee Hoyoung Gyou Gunsaeng Shin Hyunbok Jeon Bohyun Gha llhwan Gang Gyunghun Hong wang Main Window Company Department Suprema R amp D Suprema R amp D Suprema M amp S Suprema R amp D M amp S Supre
138. ese for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them Please contact Suprema local Suprema sales representatives or local distributors to obtain the latest specifications and before placing your Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 4 product order Note Third party brands and names are the property of their respective owners About BioEntry and BioStation BioEntry and BioStation are biometric access control and time attendance device with algorithms awarded 2 consecutive grand prix at finger scan contest FVC2004 amp FVC2006 and standard Wiegand interface BioEntry and BioStation can replace an existing system or be added to an existing access control and time attendance system with ease BioEntry Smart is a fingerprint smart card device that seamlessly integrates fingerprint and smart card device into one device BioEntry Smart is designed to replace existing access devices like proximity or magnetic devices without additional wiring Fingerprint template is stored in each user s smart card and there is no need to store fingerprint data in a device itself This eliminates the burden of template management and networking devices BioEntry Pass is a fingerprint access device equipped with fast one to many fingerprint identification engines Enrolled with more than hundreds of user
139. evice tree the Device Configuration window for the selected BEACon is updated on the main window BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task z BEACon Configuration 0 Search Device B Add New BEACon BH Remove Device Check Status Q Refresh Device List BEACon Relay Setting BEACon Switch Setting Device Tree Relay Select Relay 1 v Relay On Relay Off amp all Devices Door 1 Unlock Setting GF 192 168 1 250 E Unlock Duration 3000 22547 New BioEntry E 192 168 1 60 Not Use S 1811 New Biostation a 192 168 1 27 W 1539 New BioStation F com 1050 New BioEntry Operation Mode Baudrate Set One Door Mode SetTwo Doors Mode 115200 Alarm ON Event Alarm OFF Event B User Management Refresh Apply to Others Suprema Inc The Device Configuration window is divided into 3 sectors Operation Mode BEACon can control up to two doors The Operation Mode window shows whether the selected BEACon is configured as one door mode or two door mode Baud Rate The Baud rate window shows the transfer speed of the selected BEACon Configuration Set up window The Configuration set up window shows the current configurations of the selected BEACon Also this window shows the configurations to be changed The configuration set up menu is divided by separate tabs such as BEACon Relay Setting an
140. ey Device Setting LAN Type fEthernet v Port 1470 WLAN Setting TCP IP Get IP address by DHCP Set IP address manually Max 1 v Server Seting O Use NotUse Serial RS 485 Serial RS 232 Mode PC Connection v Baudrate 115200 v Baudrate 115200 8 v USB Setting Slave Device Enable USB port Disable USB port Apply Apply to Others Set to Default Manual If a user verify by pressing T amp A Function Key its function key keeps same function to the following users until disabling manual mode Please pay attention to when you select manual mode Fixed Key If selecting Fixed mode and go to Function Key tab you will see highlighted Fix check box For example if you fix F1 key it is not necessary to push F1 key but just paste your finger to work for F1 function Double Mode In case of verifying two user s fingerprint it is possible to send relay for door opening or siren which is special option for higher security level Always No Time Defined Time Zone of Access Control Note Double mode is specially designed for two user s verification for secure access control Please pay attention to select this mode Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 164 Encryption Information Enable or Disable Note Go to System gt Preference Menu to make availability by s
141. f mounted Ethernet to Serial converter Input 1470 for all ports Add New Device Search BioEntry Serial Port COM Port TCP IP Search BioStation Search BioEntry Plus Baudrate IP Addr 192 168 Port 1470 USB Device BioStation USB Virtual BioStation Searching 192 168 1 77 port 1470 Detected Device New BioStation 5238 Finish Device Search 1 device s found Cancel Once device is linked correctly with network searched device ID appears with bracket under port on device tree window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 141 E L BioAdmin Server 1058 New BioEntry Plus 2686 New BioStation Si 192 168 1 77 SE 5238 New BioStation 4 1 3 USB device In case of connecting BioStation with host PC by USB select USB device and search fee All Devices E L BioAdmin Server amp 1058 New BioEntry Plus S USB Device FY 2686 New BioStation 4 1 4 Virtual Terminal You can use a USB memory as a virtual BioStation terminal After connecting a USB memory to BioStation store the necessary information such as user information log and various setting values of the BioStation Then by connecting the USB memory to the host PC you can utilize most of the BioAdmin menus with the connected virtual terminal Note To use a virtual terminal OS of your host PC should recognize
142. fer remaining user information after deleting a specific user you can also delete such deleted user information from device Transfer checked user to device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 129 Select a Device Me AI Devices MB BioAdmin Server MINE 1334 New BioStation Me 192 169 1 254 MEG 254 New BEACon Me 943 New BioEntry MO 1050 New BioEntry Me 192 168 1 74 MINE 1539 New BioStation Overwirte users with different information Transfer checked users to device is to transfer user DB in host PC to device To run a device user data including fingerprint information should be transferred to device after user enrollment User information such as user ID finger scan information access group and security level is transferred through this process Transfer procedure is processed in selected device selected group or all devices linked on network In how to select check user user information can be transferred selectively Detailed operating process is as follows Check a user to transfer Press transfer checked users to device button Select a device on select device window In case user ID is same but user information is different if you check overwrite data in host PC will overwrite the same user s information in device f not able to find a selected user in device new user data is transferred from host PC database to device Copyright
143. file in the created folder as data serial number type at the server installed path all data can be restored as original backup status All administrator amp user information rules and log history are restored at the corresponding point but data after restoration will be disappeared Lock all devices Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 272 10 1 5 10 1 6 10 1 7 Lock unlock linked all BioEntry and BioStation while using BioAdmin software If administrator clicks lock all devices menu all linked BioEntry and BioStation are locked and once locked they dont react to any external packet except unlock command In case of BioStation connected to the server lock device does not support Unlock all devices By clicking unlock all devices menu user can unlock all locked BioEntry and BioStation If lock password has been set user needs to enter password to unlock Enter locking password DevicelD 21929 is locked Load BioAdmin 1 X data Load BA ver 1 x Data tr Load User list Setti Preference Load Log list e Click Load BioAdmin 1 X data menu to import previous user data and log data generated while using BioAdmin software version 1 Note This menu can be used at a time of first execution of BioAdmin software version 3 0 only It is because data is created anew after deleting existing data when importing previous data running this menu
144. g output 0 65535 pulses in msec High duration duration of pulse in high state in msec 0 65534 65535 continuously active until new output event occurs Low duration interval between consecutive pulses 0 65535 where the output signal remains low Count Number of pulses 0 infinitely repeated until new output event occurs 1 255 Programming example of output pattern Assume that a user want to assign an alarm signal at output port O generating following patterns On identification success or verification success for duress finger the device sends blinking output during 5 seconds When temper switch is on the device sends steady output during 10 seconds Programming procedure is as follows First select a target device on the network window Disable currently selected events on output 0 by moving enabled ones to the disabled sector Program the required events by enabling each event followed by editing output pattern parameters as follows Event to be enabled Output pattern parameters Verify Duress Delay 0 High 500 Low 500 Count 5 Identify Duress Delay 0 High 500 Low 500 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 215 Count 5 Delay 0 High 10000 Low 0 Count 1 Temper Switch On Press the Apply button to transmit the new configuration to the target device 4 8 4 L
145. ght 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 244 Access Group Setting Access Group New Access Group 1058 New BioEntry Plus 1058 New Time Zone Del All Device K 058 New BioEntry Plus Access Time New Time Zone To start with BioAdmin v4 2 only please follow the direction Select a device and add or delete Time Zone of device For special user in specific time select device and change Default Access Group to Full Access Go to Add New Time Zone and make access time for a special user Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 245 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information User ID 853 Edit Private Information Name Dongsuk Suh Company Suprema Department R amp D Manager Details Access Group Phone 012 345 6789 Status Active Mobile 098 765 4321 Group 1 Full Access v None E Mail dsuck anymail Group 2 Er Reese Gender Male Group 3 ge SE Group Date of Birth 6 14 1970 Group 4 None Start Date 1 1 1970 Entrance Limitation BioStation Expiry Date 12 30 2030 v 0 Daily Limit 0 00 23 59 Timed APB Minute Other Information Password BST Admin Leve Normal User
146. he definition Press Next Wiegand Configuration Parity Choose bits for calculating parity 1 2 Parities o EPEE ERREPRERE s e RRERERR DR Ces _ a M IKKEEED o oe PITTA BE e Press the bits which are used in calculating the first parity bit In this example they are BIT1 BIT22 Press gt gt Press the bits which are used in calculating the second parity bit In this example they are BIT23 BIT42 Press Next Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 221 Alternative values In 26 bit standard you can specify alternative FC code In Custom format you can specify alternative values for non ID field If alternative values are set the BioEntry device will replace corresponding fields with these values before sending outputs Wiegand Configuration Alternative Value 26 Bit Standard Custom Format Field D Ven Bit 1 to Bit 7 Alt Value Advanced options You can specify the characteristics of Wiegand signal and the advanced options in the last page of the wizard Advanced options are not available for Pass Through format Wiegand Configuration Advanced Options Pulse Width us 50 Pulse Intervalfus 2000 Advanced Options C Fail ID C Inverse Parity on Fail Use Default Uses default values for Wiegand signals Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 222 Pulse Width
147. heck In Check Out In Out Selected events are used as basis of T amp A result and computation of work hours if you do not want to apply Late In or Early Out to a specific key check on Calculate as normal check in check out event Changes will apply only when report is updated after changing BioStation function key setting 9 3 Setup Monthly Schedule By setting monthly schedule you can select working day and holiday which are used as a basis of T A report On holiday late in early out absence are not applied Work hours on holiday will be added to the holiday work time Press Setup Monthly Schedule button Monthly Schedule Setting Name New monthly schedule Monthly Schedule First Week Sun Tue Second Week Sun Tue Third Week Sun Tue Fourth Week Sun Tue Fifth Week Sun Mon Tue Sixth Week Sun Mon Tue Legend C Working Day C Holiday After changing this setting please update report again Save Cancel Select Working Day and Holiday and press Save button To apply new monthly schedule to T A report check on the Rebuild All of the Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 264 Report List window and press Update Report button 9 4 Group Configuration for T amp A Control You can make a group for the rules on T amp A event control using the
148. icating that the device is waiting for finger scan for verification Place a finger on the sensor If the user is successfully verified steady green LED appears with one beep sound Otherwise red LED appears with 3 beep sounds Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 98 2 4 2 4 1 2 4 2 On successful verification the Wiegand string is also sent to the controller which can be checked by operation of relay on the controller Quick start with BioEntry Pass This section describes the basic procedures to operate BioEntry Pass without a PC device Step 1 Hardware installation In this configuration the device is connected to an external controller via Wiegand interface as well as to the host PC through RS485 interface It is assumed that the controller supports the standard 26 bit Wiegand format as default of BioEntry device BioEntry Pass Wiegand I F Z 2 O 9 Ka GND Access Controller 9 24Vdc To other controllers or host computer Host PC For more details on the installation refer to the BioEntry Installation manual or BEACon Operation Manual Step 2 Search new device Run BioAdmin software Enter Login ID and password By factory default the initial Login ID is admin and the password is blank Select Device Management on the Main menu then device management page will appear on the main window
149. ice Me AI Devices L BioAdmin Server KR 1334 New BioStation Me 192 169 1 254 MEG 254 New BEACon MS 943 New BioEntry ME 1050 New BioEntry Me 192 168 1 74 KR 1539 New BioStation C o Cone The smart card layout window is activated only for BioEntry Smart model If the selected device is BioEntry Pass this menu will not be activated Press the OK button to save the new smartcard layout to the PC USB smartcard device writer The saved layout is also applied in issuing a new smartcard using PC USB smartcard device writer Factory default initial setting layout Factory default smart card layout is as follows _ MOQUER 11111 E CIS Index Template 1 Data RW Unavailable Unused Template 2 Data Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 237 6 Access Control In the menu time span and access group may be designated Time span and access group are used to limit user s authority to allow their access according to the rules Although up to BioAdmin 4 1 version the access control may be used as it is new access control function may be also used easily However to use the new access control function the existing setting is disabled if a user is to use the new access control function with the previous items it is possible to select which function is to be used If the selection is changed BioAdmin Client should be resumed if using the existing
150. ice Device Type BioEntry Plus Firmware Version V1 0_071009 Ye Check Status eera SCH Operation Mode Network Setting Entrance limit Setting Door Setting UO Setting Command Card Wiegand Q Refresh Device List d J Device Name 1058 New BioEntry Plus Device ID 1058 BioEntry Plus Time SR Ge Date 19 2007 Syne with Host PC Time evices BioAdmin Server S SCH 7 r BS g 192 168 1 67 Time 8 15 17 PM Get Time Set Time SE 1058 New BioEntry Plus a com Basic Setting E 5238 New Biostation Operation Mode Setting All Always Double Verification Mode Card Fingerprint No Time Double Verification Mode Only Card No Time Double Verification Mode Fingerprint No Time C Double Verification Mode Fingerprint Setting Security Level Normal 1 N Fast Mode Auto Scan Timeout 10 Matching Timeout 3 Refresh Apply ApplytoOthers Setto Defaut W Suprema Inc 4 7 2 Detect Device via UDP Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 190 BioEntry Pl Date All Devices EI L BioAdmin Server 5238 New BioStation Time 1058 New BioEnt taali i 2686 New BioStal Check Status Setti Set Time bratio Rename Device Remove from Server Reset Device d Fit WEN o Factory Default Delete All Log yerpr Fingerpr Setup
151. ick Next to continue or Cancel to exit Setup Cancel After copying all files set up the Open SSL BioAdmin Server Configuration and Database Setting If you finish the Open SSL set up following window will appear which is to set up the BioAdmin Server configuration In most cases you can maintain its default value for the BioAdmin Server configuration Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 22 ZC BioAdmin Server Config Stopped Connection TCP Port 1480 M i CP Por E ax Connection 32 d Database Database Type Access DB mdb Connection String Provider Microsoft Jet OLEDB 4 0 Data Source C Program Files BioAdmin Server BioAdminD ata mdb Persist Security Info False OpenSSL Path CADpenSSLbin openssl exe Pass Phrase MI Status Status shows the current version and status of the BioAdmin Server By pressing Start or Stop button you can start or stop the operation of BioAdmin Server If BioAdmin Server is stopped logs from the networked BioStation will not be stored on the database of the BioAdmin Server and BioAdmin Client will not be able to access to the BioAdmin Server If you changed any server configuration or database setting stop the BioAdmin Server and restart it Before you restart the BioAdmin Server changes in the BioAdmin Server configuration or database will not be applied to the BioAdmin Server Co
152. iegand setting page is updated on the windwo Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 203 BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info i Search Device Device Name 1058 New BioEntry Plus Device ID 1058 a Add New BEACon J W Remove Device Device Type BioEntry Plus Firmware Version 1 0_071009 il YQ Check Status 8 O Setting Command Card Wiegand E Refresh Device List NL S Wiegand Format O Not Use 5 ES all Devices Format 26 bit Standard Change Format BioAdmin Server 2 Z 192 168 1 87 EAAA AAAA AIII IIIT III IIII 10 Total Bits 26 SE 1058 New BioEntry Plus P GE com IDBits 16 5238 New BioStation 1 1D bit O ParityBit Odd E ParityBit Even 7 A B Fields FC Code Disable Default Field Data l Refresh Apply to Others Set to Default Suprema Inc Wiegand format It is possible to set new Wiegand format by using Wiegant setting wizard Pressing Format change shows the Wiegand Setting wizard Select one of there formats supported in the first page 26 bit standard Wiegand format 26 bit standard format is the most widely used and consist of 8 bits FC code and 16 bits ID In 26 bits standards formation bit definition and parity bit may not be changed Copyright 2007 by Suprema Inc http
153. ield DZ Non ID Bit 1 to Bit 7 Alt Value 1q 4 5 9 Door Setting Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual BioAdmin Software System User Management Device Management Access Control Device Management Task i Search Device a Add New BEACon W Remove Device YQ Check Status Ei Refresh Device List 5 ES All Devices BioAdmin Server 192 168 1 87 1058 New BioEntry Plus o E com W 5238 New Biostation Device Configuration Device Info 183 Device Name 5238 New BioStation Device ID 5238 Device Type BioStation BSR OC Operation Mode Image amp Sound Notice Wiegand Door Mode Door 0 Name Door 0 O No Door Outside Device 5238 Inside Device Not Use Door Relay Disable Door Open Period sec Exit Button Switch Type Door Status Switch Type wi Door Open Alarm sec 5 All Events v v Driven By Network Setting Function Key Firmware Version 1 4_071008 V03 Device Setting Door Setting UO Setting Entrance limit Setting Door 1 Name Outside Device Inside Device Door Relay Door Open Period sec Exit Button Switch Type Door Status Switch Type Door Open Alarm sec Driven By Lock Time Copyright 2007 by Suprema Inc Lock Time None Unlock Time None Unlock Time Anti passback APB Type Reset Time Minute l Refresh Apply to Others Set to Default
154. ificate G Terminal ID 1334 Database Select the database type of the BioAdmin Server BioAdmin Server uses Microsoft Access Database by default If you are not using any extemal database leave this field just as its default MS Access DB mdb Additionally if you are already using MySQL or SQL Server BioAdmin Server also supports MySQL and SQL Server However BioAdmin Server does not provide any new installation of the MySQL or SQL Server For the details of the database management refer to the chapter 1 4 3 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 25 After selecting the database type press Configure button and set up the database If you are using the default mdb file select Microsoft Jet 4 0 OLE DB Provider E Data Link Properties Provider Connection Advanced Al Select the data you want to connect to OLE DB Provider s MediaCatalogDB OLE DB Provider MediaCatalogMergedDB OLE DB Provider MediaCatalogwebDB OLE DB Provider Microsoft ISAM 1 1 OLE DB Provider Microsoft Jet 4 0 OLE DB Provider Microsoft OLE DB Provider For Data Mining Services Microsoft OLE DB Provider for Indexing Service Microsoft OLE DB Provider for Internet Publishing Microsoft OLE DB Provider for ODBC Drivers Microsoft OLE DB Provider for OLAP Services 8 0 Microsoft OLE DB Provider for Oracle Microsoft OLE DB Provider for Outlook Search Microsoft OLE DB Provider for SOL
155. ined Time Zone of Access Control at main menu Please refer to 6 1 Time Zone Setting Time Zone should be transferred to all devices to select in 1 N operation mode T amp A function key T amp A function key is to enter T amp A event before entering fingerprint for T amp A control such as in out in duty out duty In BioStation usually from F1 to F4 function keys are used for this and if necessary function key can be increased up to 16 keys T amp A key mode can be chosen from function key mode and none mode In case of using BioStation for exclusive use of access control choose none while in case of using for T amp A control choose function key Pressing T amp A key on BioStation first and then enter fingerprint to record applicable T amp A event in a log In the future T amp A software this log information can be used for various T amp A and salary control data T amp A Mode BioStation Function Key can be changed by below Auto T amp A mode is automatically changed by pre defined function key of BioStation If selecting this Auto mode and go to Function Key tab you will see highlighted Auto Mode You can also select Time Zone of Access Control at main menu Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 163 Image amp Sound Notice Wiegand Door Setting I O Setting Entrance limit Setting Operation Mode Network Setting Function K
156. ing log data Transfer Copyright 2007 by Suprema Inc E Cancel http www supremainc com BioAdmin User Manual DBMigrationTool DB Information DB Version Number of Users Number of Logs Latest Log Date 31 BioAdmin mdb 20060501 45 902 7 9 2006 3 57 26 PM Transferring holiday code data Holiday code data transferring complete Transferring time code data Time code data transferring complete Transferring T amp A rule data T amp A rule data transferring complete Transferring T amp A event data T amp A event data transferring complete v After the transfer press Close button Installation Complete BioAdmin Server was successfully installed If you are using the OS Windows 2000 or XP BioAdmin Server will start as its background service After this initial installation BioAdmin Server will run automatically 1 4 2 How to install BioAdmin Client Start Installation Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual Le BioAdmin 4 0 InstallShield Wizard 32 Welcome to the InstallShield Wizard for BioAdmin 4 0 The InstallS Choose Destination Location BioAdmin 4 0 InstallShield Wizard Choose Destination Location Select folder where setup will install files Setup will install Bia amp dmin 4 0 in the ing folder uter To continue clic
157. int please try to place a finger correctly with care 2 Incase of low acceptance ratio the following actions are recommended Delete enrolled fingerprints and re enroll the fingers Enroll the same finger additionally Try with another finger if a finger is not easy to enroll due to scar or wom out 3 For the case when an enrolled fingerprint can t be used due to scar or holding a baggage it is recommended to enroll more than two fingers 1 4 Concept of BioAdmin 4 2 BioAdmin 4 2 is operated as server client application so that users can operate the BioAdmin Client program from multiple host PCs at the same time If the users connect BioStation to the BioAdmin Server logs from the BioStation will be automatically stored on the database of BioAdmin Server real time In this server client application BioAdmin Client is used as the user interface to manage the data If the user does not connect the BioStation to the BioAdmin Server logs will not be Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 19 1 4 1 stored on the database automatically BioAdmin Server is designed only for BioStation Therefore you can not use the BioEntry or BEACon as the server client application This chapter describes the installation and operation of BioAdmin Server and BioAdmin Client programs How to install BioAdmin Server Select the PC to be used as the server Server PC should be always tune
158. ioEntry Factory defaults list of parameters for BioEntry Pass is as follows Factory defaults of parameters 210 Operation mode Factory defaults 1 1 verification BioEntry Smart 1 N verification BioEntry Pass Selectable values 1 1 verification 1 N identification Both Security level Auto Normal 1 1 000 3 10 000 1 10 000 3 100 000 1 100 000 3 1 000 000 1 1 000 000 3 10 000 000 1 10 000 000 3 100 000 000 1 100 000 000 Auto Normal Auto Secure Auto More Secure Image quality Moderate Weak Moderate Stronger Strongest Sensitivity O lowest to 7 highest Scan timeout 10 sec 1 to 20 sec or Infinite Matching timeout Infinite 1 to 20 sec or Infinite Fast mode 0 Normal 0 Normal to 5 Fastest I O Setting Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 211 BioEntry provides 2 programmable inputs and 2 programmable outputs which can be used to interface with external devices UO Setting menu refreshes the main window to manage the I O settings By factory default no functions are defined for each programmable O s System Setting UO Setting LED Beep Wiegand Setting Card Configuration Input 0 Se Function TN v min 100 ms Input 1 Function No Action v min 100 ms Output 0 Disabled Event Enabled Event Delay ms o Hi i BS Fail Pigntm
159. irectory Default backup directory for database can be specified on the preference page Related backup files will be stored on the specified directories In case of BioAdmin Software v4 0 above this option cannot create a backup path but backup file at the server installed path Automatic Backup Option By checking on the Use Automatic Backup check box you can automatically save the backup database whenever you close the BioAdmin software In case of BioAdmin Software v4 0 above the backup file is created at the server installed path which is similar to manual backup You can select the period of the automatic backup between everyday and every month This automatic backup replaces the old database with the new database at the termination of BioAdmin software Note automatic backup option saves data on the basis of closing BioAdmin software Thus in case of not running BioAdmin or not closing BioAdmin after running data is not saved Security Option Security option is used to encrypting fingerprint template data which is used between host PC and BioStation By encrypting the template data you can Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 276 enhance the security level of of the system Security option should be used only when there is no fingerprint data on the BioStation Otherwise BioAdmin will remove all fingerprint templates on the BioStation Security Option
160. is entered Relay 0 v Priority 0 Add Device Display the devices to be set at present Port Select an output terminal to be set in a selected device Alarm On Event It may set so that if a listed event occurs the output is generated from the port of a selected device How to add Event Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 201 Add Event 1058 Relay 0 Event Event Auth Success Device H 058 v Priority Signal Setting Delayims 0 Count High ms 0 Low ms Event Itis set so that if a selected event occurs the output is generated to the port of the previously selected device Device Select a device to generate an event Priority By allowing priority to a function it may prevent a priority event from being hidden or turned off preceding over low priority function Signal Setting Delay delay time before output is generated Count frequency to repeat off on interval High time when output is generated Low Time when output is not generated Alarm Off Event If a listed event occurs it may release an output of which priority is equal to or lower than the priority of the port of a selected device 4 7 8 Command Card Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 202 BioAdmin Software System User Management Device Management Access
161. k Next To install to this folder click Next To install to a different folder click Dro and select another Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 33 Choose the hard disk drive on which BioAdmin Client is to be installed By default BioAdmin Client is installed in C Program Files BioAdmin Installation Complete BioAdmin 4 0 InstallShield Wizard InstallShield Wizard Complete Setup has finished installing Biaddmin 4 0 on your computer e9 BioAdmin Client was successfully installed Close the installation program and execute the BioAdmin Client 1 4 3 Using MySQL or SQL Server database You can use MySql or SQL Server database by the following procedures Using MySQL database If you are already using MySQL Server you can use the MySQL database instead of mdb Execute BioAdmin Server Config menu Click the Configure button on the Database field Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 34 On the Data Link Properties window select Microsoft OLE DB Provider for ODBC Drivers and press Next button E Data Link Properties Provider Connection Advanced Al Select the data you want to connect to OLE DB Provider s MediaCatalogDB OLE DB Provider MediaCatalogMergedDB OLE DB Provider MediaCatalogwebDB OLE DB Provider Microsoft ISAM 1 1 OLE DB Provider Microsoft Jet 4 0 OLE DB Provider Micro
162. l BioStation BioE ntry Plus Device ID ESLAMA Wiegand Card ID Setup Device Defaut BioE ntry Smart Pass 1st Template 2nd Template Device Default v Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Scan Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 64 Press scan button place a finger on BioStation scanner twice and input the first fingerprint information User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 1 1 Security Level BioStation BioEntry Plus Device ID 2686 New BioStation Wiegand Card ID Setup Device Default v BioEntry Smart Pass 1st Template 2nd Template D evice Default v C Duress Smart Card AF ID Smart Card GAN SAND RF 000 0 A KW AN at SE Ee Be ak fff Af fate ff ot I7 8 User ID UserlD 853 ANN E Deelt D s Dm e Dip Dip D Dia ue Dr Dr Dr D Dr D See A CW cb NS ct ammm Aaen C Bypass Card gg NN PGT a A A Ate a ae A AP etal al ee a fo E Read Card ae n A d ae Pee Write Card Format Card Delete Verification Test Input the second fingerprint information in the same way as the first fingerprint information input process Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual
163. lect All Door Status Monitoring On Door Name Device ID Status Last Event Alarm Event Door 0 1058 Door Closed Door 0 2686 Door Closed 2007 10 16 23 42 55 I 8 User Management Device Management SmartCard Ss Access Control E Log List Reports Checked Users 1 Total Users 1 a Suprema Inc It supports the status of access door Selecting real time monitoring and selecting Access door shows the monitoring screen of access door 7 4 1 Door Open Close H checking the checkbox of access door to open from the access door list and click Door Open you may open or close the door However in the case it analyze it only with input information unlike the determination whether it is closed so it may differ from the actual status Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 249 7 4 2 Alarm Release f there is an event to generate an alarm to open door or forcibly open door the alarm status may be canceled by clicking alarm release However alarm release may require the operation of admin Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 8 Log List The Reports menu covers the following operations Management of log database stored on host PC Upload new log events from BioEntry and BioStation into the log database By selecting the Log List the log list page is upd
164. lete issuing process if the site key was not changed from factory setting Site Key Current Site Key C Change Site Key Retype Site Key On the user list window you can see the serial number of the smart card Smart Card RF ID S N 1077514292 UserllD 853 RF ID 0 C Bypass Card Read Card Select the Smart Card menu Then you can see smart card is added on the list Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 2 3 4 2 3 5 E BioAdmin Software System User Management Device Management Access Control SmartCard SmartCard List Task Card No User ID User Name ER Issue User Card 1077514292 853 Dongsuk Suh Configure Smart Card ine Configure Card Layout BS Configure Card Wiegand Delete Smart Card 25 9 Access Control 97 Issuing Date 2006 04 13 00 00 00 SmartCard Number 1 Step 4 Enroll user ID in the external controller Suprema Inc It is required that the issued user ID is also registered to the controller to grant access when the Wiegand string for the user is received If you are using Suprema s BEACon controller you can just skip this additional registration to the controller Step 5 Authentication Test Procedure to test verification using the user s smart card is as follows First place the user s smart card in front of the device below the sensor Then amber LED blinks rapidly ind
165. lumn 3 4 Select user Users can be chosen for selective processing of operations such as transfer removal or exportation You can select the required user simply by using the check box on the user list Selection Tool Check All Uncheck All Check Reverse Check Selected Users Uncheck Selected Users Check All Check all users Uncheck All Uncheck all users e e Check Reverse Check all users except the users who were originally checked Check Selected Users Check the selected users e Uncheck Selected Users Uncheck the selected users 3 5 Add New User The Add New User button enables the pop up window to register user data on host PC Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information Details Phone Mobile E Mail Gender Date of Birth Start Date Expiry Date UserID Name Company Department Title 012 345 6789 118 853 Edit Private Information Dongsuk Suh Suprema R amp D Manager Access Group Status Active 099 765 4321 Group 1 Full Access dsuck anymail Group 2 Male Group 3 6 14 1970 Group 4 14141970 Entrance Limitation BioStation 12 31 2030 e Daily Limit 0 0 00 23 59 Other Information
166. m Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 94 Device ID 42965 New BioE ntry Wiegand Card ID Setup 1st Template C Duress di If cf ro OF ea EE A ravers S SC E 8 D n an n Dn Dn in SSH n Dina D WAN ae Sara ff of e NS ae De N N a SSN ON we ep Liebe e Dr Dr D D sc en A ag RE EE A d af ef Here NG ee AA E erte ar or 2nd Template Duress 1 1 Security Level BioStation BioEntry Plus Device Default v BioEntry Smart Pass Device Default B Smart Card AF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Read Card Write Card Format Card Acquire second template similarly to the acquisition of first template Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule 1 Device ID 42965 New BioEntry v Wiegand Card ID Setup 1st Template C Duress x SN AEN A LEE Ee EE ay ee SE eA E Cen D n NN E Se e e d NM 2 E t Zo 2 A Al ey z 7 d d H i gar eee e Dr Dr D D ct a EES SE S eer ar EE AA pote Sh AE Hee NN a ae A decal el atl rr 2nd Template C Duress y aN aN
167. m Started System Started System Started Delete All Identify Fail Identify Fail System Started System Started Identify Fail Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Delete All Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success User ID User Name D Nakwon Lee ChangGyun Lee Hoyoung Gyo Gunsaeng Shin Hyunbok Jeon Bohyun Gha Ilhwan Gang Gyunghun Hong Jonguk Hwang Dongsuk Suh Nakwon Lee ChangGyun Lee Hoyoung Gyo Gunsaeng Shin Hyunbok Jeon Bohyun Gha Tlhwan Gang Gyunghun Hong Suprema Inc Source BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation 253 v In case of pressing stop auto uploading button user can release set auto uploading Also in case of disabled mode when setting time transfer user can release ti me transfer Once auto uploading is released status auto uploading off is indicated on task box Copyright 2007 by Su prema Inc http www supremainc com
168. ma Suprema Suprema Suprema Suprema 50 Title Manager z 3 3 ra 2 Fi ZS lt Z Manager Engineer Manager Chief Engineer Wei i i A lt lt Manager W Suprema Inc Command menu bar contains command items supported by BioAdmin software which are grouped into 4 categories System admin Account back up database restore backup lock all devices unlock all devices upload 1 x version data preference BioAdmin information and close User management add new user company management department management title management and setup custom fields Device management add new device add new BEACon set time upgrade firmware upload password initialization code password initialization site key setting Access control time code definition holiday definition time zone definition door zone definition and access group definition Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 51 1 7 2 1 7 3 1 7 4 1 8 Main menu Major command menus can be accessed by buttons on the left pane such as user management device management smart card access control monitoring log list or report Task and Utilities Task window shows sub menus for the selected main menu Utility window shows the User selection tool Device tree and Log filtering tool Main window On each command menu relevant information is upd
169. ma Inc http www supremainc com BioAdmin User Manual 102 Select the Add New User menu on the task window and then the pop up window appears User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information Details Phone Mobile E Mail Gender Date of Birth Start Date Expiry Date Password User ID Name Company Department Title Edit Private Information Male 10 16 2007 17141970 12 31 2030 e 1 Other Information Access Group Status Group 1 Group 2 Group 3 Group 4 Entrance Limitation BioStation Daily Limit Timed APB BST Admin Leve Active Full Access None None None 0 00 23 59 Minute Normal User Enter the user information on the User Information tab Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 103 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information User ID 853 Edit Private Information Name Dongsuk Suh Company Suprema Department R amp D Title Manager Details Access Group Phone 012 345 6789 Status Active Mobile 098 765 4321 Group Full Access E Mail ds
170. min O30min O 60min rr ee Once auto uploading is applied status auto uploading on is indicated on task box Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual E BioAdmin Software System User Management Device Management Access Control Log List Task g Get Recent Logs Auto Upload CS Stop Auto Uploading RS Upload All Log IS Export Report Status Auto Uploading On Filtering Tool Device ID UserID Event C Source 21 142007 2128 2007 g List Date Time 2007 02 28 16 00 58 2007 02 28 16 02 16 2007 02 28 16 43 17 2007 02 28 17 11 40 2007 02 28 17 59 55 2007 02 28 20 23 19 2007 02 28 21 21 05 2007 02 28 22 04 59 2007 02 28 22 05 07 2007 02 28 22 05 41 2007 02 28 22 13 17 2007 02 28 22 20 13 2007 02 28 22 36 11 2007 02 28 22 36 12 2007 02 28 22 36 14 2007 02 28 22 36 15 2007 02 28 22 36 16 2007 02 28 22 36 17 2007 02 28 22 36 19 2007 02 28 22 36 20 2007 02 28 22 36 22 2007 02 28 22 36 31 2007 02 28 22 36 47 2007 02 28 22 42 47 2007 02 28 22 42 48 2007 02 28 22 42 50 2007 02 28 22 42 51 2007 02 28 22 42 52 2007 02 28 22 42 54 8 2 3 Release auto uploading Device ID 1539 1539 1539 1539 1539 1334 1334 1334 1334 1334 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 1539 Event System Started Delete All System Started Syste
171. mode is 1 1 If the mode is 1 N the bits other than ID field are set to 0 For example assume that 32 bit Pass Through format is composed as follows XII MHIX XXXII IHX left most bit is Oth bit BITO I Id field X Unknown field You can configure this format in the following sequences Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 180 Wiegand Configuration Format Total Bits 32 pn 26 J Format e CEET KEENT e Deen e TERERERKERERERT a even ay aSlEHEHEHE ER PTD 47 9 odd Parity s GRD TODD e Uu 1 Enter 32 in the Total Bits field 2 Select ID bits according to the definitions 3 Press Next You cannot specify parity bits in Pass Through mode Custom format When users know all the information of a Wiegand format Custom format can be defined When a Wiegand input string is detected BioEntry device checks the parity bits first If all the parity bits are correct the device extracts ID bits and starts verification with the ID Users can also set alternative values of each field and enable advanced options such as Fail ID If the verification succeeds the device outputs a Wiegand string The output string may be different from the input string according to the alternative values and advanced options For example assume that 44 bit Custom format is composed as follows EAAAAAAA III HHI BBBBBBBI WII IO left most bit is Oth bit BITO E Ev
172. n will restart automatically DB Migration Tool If you were BioAdmin version 3 X you need to convert the data from BioAdmin 3 1 to BioAdmin 4 X If you do not need the old data press Close button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 29 DBMigrationTool Select MDB File BioAdmin mdb DB Information DB Version 20060501 Number of Users Number of Logs Latest Log Date 7 9 2006 3 57 26 PM Select the old BioAdmin mdb file DBMigrationTool A It will delete all data Continue Press Transfer button to transfer the old data to BioAdmin 4 X If you transfer the old data old data will be deleted Therefore if necessary back up the old data before transferring to BioAdmin 4 X This data transfer may take time depending on the size of the existing database Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual gt DBMigrationTool Select MDB File DB Information DB Version Number of Users Number of Logs Latest Log Date 30 BioAdmin mdb 20060501 45 902 7 9 2006 3 57 26 PM User card information data transferring complete Transferring company data Company data transferring complete Transferring department data Department data transferring complete Transferring title data Title data transferring complete Transferr
173. n the BioAdmin Software All of user s smart cards will be automatically shown on the Smartcard list of this menu The Smartcard menu covers the following operations Issue User Card Manage Smartcard Configure Card Layout Configure Card Wiegand Delete Smartcard E BioAdmin Software System User Management Device Management Access Control SmartCard SmartCard List a Task Card No User ID User Name Issuing Date ER Issue User Card 1077514292 853 Dongsuk Suh 2006 04 13 00 00 00 Configure Smart Card GO Configure Card Layout oc Configure Card Wiegand D I Delete Smart Card SmartCard Number 1 a Suprema Inc 5 1 Configuration of Smartcard page By selecting Smart Card menu Smart Card management page is updated on the main window The Smartcard page is divided into 2 sectors Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 231 Smartcard List The Smart card database is under central management on host PC The Smartcard list includes the detailed list of smart cards issued on BioAdmin software Task box Task box includes buttons to control the basic operations of the Smartcard page 5 2 Smartcard List The Smartcard list includes the following information of the Smartcards Card Number UserID User Name Issuing Date Expiry Date 5 3 Card issue The Issue User Card menu enables a pop up window to issue a user s smart
174. nality into customer s application software using SDK which contains versatile API s to control BioEntry and BioStation For further information please refer to SFM SDK Reference Manual BioStation SDK manual and UniFinger Engine SDK Reference Manual Fundamentals This chapter provides introductive information on BioEntry BioStation and BioAdmin including basic concepts operation flow and overview of the software Finger scan device Fingerprint access device is a device to authenticate the identity of each person using fingerprints It can be easily integrated into access control system by connecting with access control panel through industry standard interface such as Wiegand interface Since fingerprints contain biometric features which are unique for each person fingerprint access device can be substituted for existing access devices such as barcode magnetic card keypad or RF card devices with high security and efficiency Finger scan smart card device Fingerprint smart card device is an advanced model of fingerprint access device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 16 which improves security of the system by integrating smart card technology Fingerprint data for each person is stored on user s smart card and the device authenticates the user by comparing the stored fingerprint data in the smart card with the input fingerprint data 1 2 3 Template A template is the bi
175. nary data representing the features of each fingerprint The fingerprint image acquired from a fingerprint sensor is converted to a template which is stored on the memory of the fingerprint access device or on user s smart card In authenticating a user a new template is also generated and compared with the stored templates 1 2 4 Enrollment Enrollment is the process to store the fingerprint template with user information Through enrollment process new users are entered into the system 1 2 5 Verification Verification is the process of authenticating an input fingerprint with the fingerprint of the specified user On BioEntry Smart a user places smart card containing personal fingerprint template and user information Then the device carries out verification process by scanning an input fingerprint On BioEntry Pass verification process can be implemented by connecting external Wiegand device such as RF card device which provides the current user ID 1 2 6 Identification Identification is the process of searching a matched fingerprint among the stored fingerprints on the device BioEntry Pass and BioStation basically operate in identification mode which requires no additional input except the placement of a finger 1 2 7 User database User database includes user ID user name fingerprint templates and so on BioAdmin software is based on the central management of user database That is the user database is created upd
176. nc com BioAdmin User Manual 76 You can type phone mobile e mail gender date of birth details and User Data Information will be indicated as Start Date which can be configured Expiry Date of user In case of applying access control please check mark Active of Access Group Status and select group what you already generated In addition private password can be generated which is used for password verification Daily Limit is to make verification available of daily limitation In case of setting timed APB it will be possible to verify it again after at least one time verification Please click Custom Fields to create more detailed user data information Click fingerprint tab to register user e fingerprint information The method of fingerprint registration is divided by two via USB fingerprint scanner and BioEntry Plus device Same as BioStation The method via USB fingerprint scanner is following as Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 77 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 1 1 Security Level BioStation BioEntry Plus Device ID fi 058 New BioEntry Plus _ Wiegand Card ID Setup Device Defaut ze BioEntry Smart Pass _ 1st Template 2nd Template Device Default v Duress Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853
177. nce Limit Zone Setting Sub zone Nam Limitation Zone Entrance Limit By Time Period 0900 z 1000 Max Number of Entrance Max Number of Entrance Max Number of Entrance Max Number of Entrance 30 Time Limit for Re entrance min 0 No Limit You can type Entrance Limit By Time Period and Max Number of Entrance sg You can also set minimum time in minute to allow repeat entrance 4 5 Manage BioStation device If you select BioStation on device list the device setup window of selected BioStation is updated on main window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 159 BioAdmin Software System User Management Device Management Access Control Device Management Device Configuration Task Device Info ae i Search Device Device Name 5238 New BioStation Device ID 5238 Bi Add New BEACon B Remove Device Device Type BioStation BSR OC Firmware Version V1 4_071008 V03 YQ Check Status Refresh Device List Image amp Sound Notice Wiegand Door Setting I O Setting Entrance limit Setting Refresh Device Lis Operation Mode Network Setting FunctionKey Device Setting ork BioStation Time All Devices Date 18 2007 4 Syne with Host PC Time BioAdmin Server 192 168 1 87 Time 8 18 23 PM Get Time Set Time 1058 New BioEntry Plus o E com W 5238 New Biostation e Basic Co
178. nd see the Nonworking Time by using the drop down menu Note Drop down menu on Nonworking Time is not to select a certain Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 262 Nonworking Time among the three Nonworking Times but to just show the time setting of the Nonworking Time Thus once you set up two or three Nonworking Times on this menu all of those Nonworking Times will be excluded from the working hour on report 9 2 3 BioStation function key setting On time attendance code definition page select BioStation function key setting menu and set log information and report display as below Time Attendance Code Definition Attendance Code New Attencance Code Device Setup Time Setup BioStation Function Key Setting BioStation Function Config Function Key F1 Use this key for T amp A T amp A Event vIn Event Type In v C Calculate as normal checkinicheckout event After changing this setting please update report again with Rebuild All option Detailed setting process is as follows Select applicable key Incase of using selected key as T amp A key check on Use this key for T amp A Input T amp A event for selected function key Upon Monitoring and log check Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 263 input in T amp A event for applicable key is displayed Select Even Type among C
179. nfiguration 1 1 Operation Mode ID Fingerprint No Time ID Password No Time ID Fingerprint or Password Always Card Only No Time 1 N Operation Mode Auto v 1 N Schedule Always Function Key Function Key v TeAMode Not Use Double Mode No Time Mj Encryption Information Encryption Disable Refresh l Apply Apply to Others Set to Default Suprema Inc Device setup window is divided into 2 areas Device information Device information displays type name serial number and FW version of selected device Configuration window Configuration window shows settings of selected BioStation device and enables user to correct those settings Configuration menu consists of separated tabs i e operation mode network setting function key device setting image amp sound and notice At lower part of configuration window are 4 buttons i e refresh apply apply to others and set to default Refresh call device setting again Apply apply corrected setting on the current window to device Apply to others apply corrected setting on current window to another device Device can be selected on select device window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 160 Set to default change setting as default To apply this value to device make sure to press apply button 4 5 1 Device information You can check device name device type
180. ng a device from device tree window Device name can be changed using change device name menu but device ID Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 60 can t be changed as it is fixed as one 2 1 4 Step 4 User management Select user management menu to display user management page on main window Note In user management user related information can be divided into basic information and fingerprint information Basic information includes user ID name company dept position and telephone number Fingerprint information is about user s fingerprint BioAdmin Software System User Management Device Management Access Control User Management User Management g Task User ID User Name Company Department Title Template Num Active ER Add New User There are no items to show ER Delete Checked Users Ey Transfer checked users to device Delete Checked Users from Device GO Manage Users in Device Pil Synchronize Al Users Gy Export to File Py Import from File Sa Set Access Control ine Set T amp 4 Rule Group Selection Tool Check All Suprema Inc Select add new user menu on task window to pop up a window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information User ID
181. ng entrance limit time against APB limit 4 5 10 I O Setting Make operation of each input and output setting possible through I O setting LH BioAdmin Software System User Management Device Management Access Control Device Management Task g Search Device GB Add New BEACon F Remove Device W Check Status Q Refresh Device List Sg E All Devices BioAdmin Server 5j 192 168 1 87 g 1058 New BioEntry Plus o E com E 5238 New BioStation Copyright 2007 by Suprema Inc Device Configuration Device Info Device Name 5238 New BioStation Device Type BioStation BSR OC Operation Mode Image amp Sound Notice Network Setting Wiegand Input Device ID 5238 Firmware Version V1 4_071008 V03 Function Key IO Setting Device Setting Door Setting Entrance limit Setting Device Em Port Input 0 Function Not Use Switch Type Hp Schedule Always Tamper Not Use Output Device 6238 Alarm On Event Delay ms High ms Low ms Count Priority Duration ms 200 Port Relay 0 Alarm Off Event Priority 0 Refresh amy f Applyto Others Setto Defautt Wa Suprema Inc http www supremainc com BioAdmin User Manual Input Device Function Schedule Tamper 185 5238 v Port Input 0 x Not Use v Switch Type NIO v Always v
182. ng on the Yes No field of each event If you double click the Yes field it will be changed to No and the event will not be listed on the monitoring window H you double click the No field it will be changed to Yes and the event will be listed on the monitoring window Start Monitoring By pressing the Start Monitoring button you can start the real time monitoring of the log events from all networked BioEntry and BioStation If you select another menu during monitoring mode monitoring will be stopped Event List on the monitoring window shows up to 5000 events If the number of events is more than 5000 the oldest event will be automatically deleted from the list Even though the oldest event is deleted from the monitoring list it still remains on the log data of BioEntry and BioStation Monitoring is automatically started when the menu Monitoring is selected from another menu So the Start Monitoring is needed only to restart Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 248 monitoring after pausing monitoring 7 3 Pause Monitoring By pressing the Pause Monitoring menu you can stop monitoring ZA Event List for Door BioAdmin Software System User Management Device Management Access Control Monitoring Event List D ze Task Event Door TS Setup Monitoring Ca Start Monitoring mg Pause Monitoring b Close Door Release Alarm Selected Device Se
183. ngerprint data Template Template size is configurable from 254 to 382 By factory default template size is specified as 350 bytes storing two templates on the card 5 5 3 Block CIS index block The header information is stored on the CIS index block which is depicted by red color Template data block Blocks for template 1 data and template 2 data The number of blocks for each template data is determined by template size Template 1 data is depicted by yellow and template 2 data is depicted by green respectively Unused block Blank block which is not defined by layout Unavailable block Block that is prohibited from use 5 5 4 Editing process To configure customer s layout the following procedure is required Initialize all the blocks to unused ones by pressing the Reset Layout button Select the required template size Press the Select CIS Index button and click an unused block to select a CIS index block Press the Select Template button and click an unused block to indicate the start block of template data Then the blocks of template 1 data are set automatically from the selected start block Press the Select Template button again and click an unused block to indicate the start block of template 2 data Press the Transfer button to transfer the new smart card layout to selected devices Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 5 5 5 236 Select a Dev
184. ntry Plus SF 192 168 1 254 Fast Mode Auto v Matching Timeout Infinite v B New BEACON EE 42965 New BioEntry 42714 New BioEntry Image Quality Moderate v Security Level Auto Normal SCT SmartCard Refresh Apply Applytoothers 1 Setto Default Suprema Inc Device Configuration window is divided into 2 sectors Device information Device information shows the model name serial number device name and firmware version of the selected BioEntry Configuration Set up window The configuration set up window shows the current configurations of selected BioEntry Also this window shows the configurations to be changed The configuration set up menus are divided by separate tabs such as System setting I O setting LED BEEP setting Wiegand setting and Card Layout 4 8 1 Device information Administrator can check device name device type device ID and FW version of Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 208 BioEntry Device ID number and FW version are necessary information to check a product for technical support after installation 4 8 2 System Setting User can set up the parameters of BioEntry on the System tab When this tab is selected the system setting page is updated on the main window System Setting I O Setting LED Beep Wiegand Setting Card Configuration Operation Mode Both v Baudrate 115200 v
185. o False UserllD sa Data Source BIOADMIN 50PM34 OpenSSL Path C Open3SL bin openssLexe Pass Phrase eecccece If the status is changed as Start press OK button 1 4 4 Check the BioAdmin software installation Network Configuration Configure the Network menu of the BioStation as to use the server Ask the IP address of the server PC to your network manager You can also check this IP address on Network connection page of your operation system For more details on BioStation setting refer to the BioStation Installation Guide Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 45 Local Area Connection Status General Support Internet Protocol TCP IP Address Type Assigned by DHCP IP Address 192 168 1 66 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 5 Details If you change the BioStation setting to use the server BioStation will try the connection with BioAdmin Server soon You can check the connected BioStation on BioAdmin Server Config window At this stage BioStation was just connected to BioAdmin Server but not managed by the BioAdmin Server If you issue the certificate BioStation will get managed by the BioAdmin Server Ifthe BioStation is connected to the BioAdmin Server BioAdmin Server will get the necessary information from BioStation This may take a few minutes depending on the data size on BioStation While receiving da
186. of serial set COM port and network baudrate and incase of TCP IP input IP address of BEACon to add For how to check IP address in BEACon refer to BEACon manual Input BEACon ID to add in BEACon ID field For how to check ID in BEACon refer to BEACon manual Designate and input BEACon name in Name field If you press update attached BioEntry button it starts searching applicable BEACon and linked BioEntry device As a result of search linked BioEntry ID is indicated in BioEntry 1 and BioEntry 2 fields In case of failing to search BEACon due to wrong input of IP address Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 148 4 3 or ID none is indicated here Press ok button to view searched BEACon and linked BioEntry on device list E New BEACON 42965 New BioEntry 42714 New BioEntry Remove device Select a device on task list and click Remove Device on task box to remove the selected device You can also remove a device by selecting a device on device list and clicking a right button of the mouse You can remove virtual terminal from the network by the following procedures Select a virtual terminal on the device tree and click the right button of your mouse Safely Remove USB Memory Click this menu to detach the virtual terminal from your host PC after storing data on it If you detach the virtual terminal while storing or using data it can cause a d
187. of stand alone usage check the registration using BioEntry Plus press Scan button and put your finger twice to register 1 template In case of more than two devices via networking set BioEntry Plus ID press Scan button and put your finger twice to register 1 template Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station 81 1st Template C Duress X vA Pai E Za ae i Ce fff af aerer ff ei d E 8 8 Dn n n D n n n SES Gen Dn ANN E NN Oe et fff aa oe a Be N N sc a a a gE NN A ai e Ae lf A wee FAAS feierte Aa af PAS ef Sb 44 ef fon Oe te ff of ei A 2nd Template Device ID 1058 New BicEntry Plus 1Y Wiegand Card ID Setup Duress Copyright 2007 by Suprema Inc Delete Please follow same procedure for 2 template 1 1 Security Level BioStation BioEntry Plus Device Default v BioEntry Smart Pass Device Default v Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Read Card Write Card Format Card http www supremainc com BioAdmin User Manual 82 2 2 5 User Data Information User Information Custom Fields Fingerprint User Tim
188. on Sub zone Device Zone Type 2686 1058 5238 APB Anti PassBack Zone information divides into for Entrance and Exit Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 156 Zone Management Anti passback Zone Setting Sub zone Name Office Selectable Devices Entrance 2686 New BioStation 5238 New BioStation Exit 1058 New BioEntry Plus Only user who has fingerprint verification successful for Entrance device can be verified for the Exit device which is used to manages entrance members Entrance Limit Zone setting can be applied for entrance limit function at once based on synchronized entrance log within same zone devices Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 157 Zone Management Entrance Limit Zone Setting Sub zone Name Limitation Zone Selectable Devices Zone Member 1058 New BioEntry Plus 2686 New BioStation 5238 New BioStation fa setting is limited for repeat entrance within same zone devices other devices follow the same setting which deny repeat entrance though a user is successful for entrance within same zone devices Select a device from Zone Member Device and press Next button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 158 Zone Management Entra
189. one a user does not need resuming If a user is not included in any access group it is allowed to enter every entry door However if a user is set to any basic access group the user should follow the basic entry group setting Ifa user is contained in a group but the does not have the information about the access the user may access the door with no restriction However if using a new access group function the device must have the group information ER BioAdmin Software DAR i System User Management Device Management Access Control Task Time Code Holiday Time Zone Door Zone Access Group CS Add New Time Code TimeCode No TimeCode Name Term 1 Term 2 CS Add New Holiday 0 08 00 09 00 11 00 12 00 15 00 16 00 18 00 19 00 21 00 22 00 G Add New Time Zone 09 00 10 00 12 00 13 00 16 00 17 00 19 00 20 00 22 00 23 00 BF Add New Door Zone 10 00 11 00 13 00 14 00 17 00 18 00 20 00 21 00 23 00 24 00 S z Add New Access Group X Delete L Transfer to All Readers B User Management E Device Management E Reports Total Time Code 3 W Suprema Inc Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 238 6 1 Time Code setting You can set up Time Zone by combining several Time Codes Therefore before setting up the time zone you need to set up the time code first Maximum 5 time sections can be selected for each time code Detailed operations
190. ow You can specify company name dept name user ID and user name for setting and select required type of Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 72 2 2 2 2 1 2 2 2 report such as daily report by setting period or individual report Upload log is a button to upload a log saved in device and update report button is a button which implements display prior to output listing a log uploaded device by date and individual Lastly view report is a button to preview a report Press print button to print Quick start with BioEntry Plus Step 1 Hardware Installation BioEntry Plus may set the network by using wired LAN For the detail information of installation please refer to the BEPus Installation Guide Note The LED color of BioEntry Plus can be changed by BioEntry Plus status Please refer to the page 10 of BioEntry Plus Install Guide V1 0 for further color status Step 2 Search a New Device Run BioAdmin Software Enter login ID and Password Select Device Management at the Main Window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 2 2 3 BioAdmin Software System User Management Device Management Access Control Device Management Task i Search Device a Add New BEACon W Remove Device W Check Status Ei Refresh Device List ES All Devices BioAdmin Server 192 168 1 87 e 1056
191. p 4 Event User ID User Name Ce Start Monitoring 2003 10 16 23 29 46 42714 Identify Fail D CS Pause Monitoring 2007 10 17 00 36 37 2686 Identify Success 2900002 2007 10 17 00 36 37 2686 Door 0 Relay On Status Monitoring On 2007 10 17 00 36 57 2686 Identify Fail 2007 10 16 23 36 59 42965 Identify Fail 2007 10 16 23 37 01 42714 Identify Fail 2007 10 17 00 37 06 2686 Identify Fail 2007 10 17 00 37 08 2686 Identify Fail 2007 10 17 00 37 11 2686 Identify Success 2900002 2007 10 17 00 37 11 2686 Door 0 Relay On D 2686 Identify Success 2900002 Suprema Inc 2 1 8 Step 8 Log List Select the Log List menu Then the log list window appears on the main window Select the Get Recent Logs Auto Upload button to see the updated event log data added to the existing log list of BioAdmin Log List V Date Time Device ID Event T amp A Event User ID User Name Source amp 2007 02 28 11 31 05 1334 Enroll Success 2 BioStation 2007 02 26 11 31 06 1334 Enroll Success 3 BioStation 2007 02 28 11 31 07 1334 Enroll Success 853 Dongsuk Suh BioStation 2007 02 28 11 31 08 1334 Enroll Success 861 Nakwon Lee BioStation 2007 02 28 11 31 09 1334 Enroll Success 934 ChangGyun Lee BioStation 2007 02 28 11 36 26 1334 Identify Mode 1 BioStation 2007 02 28 12 00 51 1334 Delete Success 1 BioStation 2007 02 26 12 00 51 1334 Delete Success 2 BioStation 2 1 9 Step 9 Report Select report menu to display report list on main wind
192. pyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual BioAdmin Server Config Status 42 ei 3ioAdmin Server V4 2 192 168 1 120 Running Connection SR Database SRRR LU U SaL Copyright 2007 by Suprema Inc TCP Port Database Type Connection String OpenSSL Path Pass Phrase 1480 Max Connection 32 SOL Server Provider SQLOLEDB 1 Persist Security 50PM34 Info False UserllD sa Data Source BIOADMIN C OpenSSL bin openssl exe Browse Select the database type as SQL Server Press Apply button Stop and restart the BioAdmin Server http www supremainc com BioAdmin User Manual 43 BioAdmin Server Config Status ER E Connection DN i SR a TCP Port 1480 Max Connection 32 Client List Database 8 Database Type SQL Server GR Connection String Provider SQLOLEDB 1 Persist Security Info False UserlD sa D ata Source BIOADMIN 50PM35 OpenSSL Path C OpenSSL bin openssl exe Pass Phrase eeecceee Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 44 BioAdmin Server Config Status e 3ioAdmin Server 4 2 192 168 1 120 Running Connection T TCP Port 1480 Max Connection Database u Database Type SQL Server SaL Connection String Provider SQLOLEDB 1 Persist Security Inf
193. pyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 121 Custom Fields Text Fields F Hobby MlTet2 Fax lire Ip Addr Text 4 Number Fields V Number 1 C Number 3 C Number 2 CI Number 4 Date Fields V Date 1 A Memorial Day C Date 2 eckboxes V Checkbox 1 Married C Checkbox 3 T Checkbox Car checkbox 4 Note Custom fields may look like a blank page but if you click settings on the right lower end a display where you are to set custom fields such as string number date and checkbox appears If you check such fields items are generated in blank custom fields 3 5 3 Fingerprint The next step of registration is adding user s fingerprint templates to database Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Device ID 2686 New BioS tation v Wiegand Card ID Setup 1st Template C Duress Ge ee a n Se WAN ee D Do D N EE EES E OF ae af eier e ae A z dat e el ei ei a ae a aa aah al Sara ff ff d NM d d NM 2 d d H E d L d y A Al ey z 7 d d H r Se Se Aert e e e A A A ar LA frre LLR AED p a 2nd Template C Duress Ce Dr D aN RB ee ee Pa S
194. pyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 23 Connection On this menu you can set up the networking details TCP Port Enter the TCP port This TCP port is used when you attach a BioStation to the BioAdmin Server or when you access to the BioAdmin Server from BioAdmin Client Use a unique port which is not used by any other software In most cases you can use the default port 1480 Max Connection Enter the maximum number of BioStation or BioAdmin Client which can be connected to the BioAdmin Server at the same time For example if you designate it as 50 the total number of BioStation and BioAdmin Client which can be connected to the BioAdmin Server simultaneously will be 50 Maximum number for this connection should be less than 128 If the number is less than 32 which is the default value you do not need to lower this number from the default Client List Client List shows the list of BioStations which are connected to the BioAdmin Server This list shows the IP Address of those connected BioStations and indicates whether the SSL Certificate was issued You can issue or remove the SSL Certificate on this list If the BioAdmin Server is stopped this menu will be deactivated Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 24 Client List ID Type IP Address 1334 BioStation 192 168 1 53 Terminal 1 Authorized 0 SSL Cert
195. r User can type Phone Mobile E mail Gender and Date of Birth then User Data Information will be indicated as Issue Date which can be configured Expiry Date of user Incase of applying access control please check mark Active of Access Group Status and select group what you already generated Daily Limit is to make verification available of daily limitation In case of setting timed APB it will be possible to verify it again after at least one time verification In addition private password can be created which is used for password verification Please click Custom Fields to create more detailed user data information Choose company dept and title using a combo box To add a new company dept or title information press LJ button or enter Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 63 company dept or title in information input window and then press add button To save added information press Close button Company Name Your Company Suprema To enroll user s fingerprint information click fingerprint tab Fingerprint input process is divided into one by USB fingerprint scanner and the other by BioStation device How to input fingerprint information using USB fingerprint scanner is as follows User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule 1 1 Security Leve
196. r Manual 279 Company Management Department Management Title Management Setup Custom Fields te Checked Ileers fram Nevire User management menu on menu bar supports following functions Add New User Company Management Department Management Title Management Setup Custom Fields For detailed setting refer to chapter 5 user management 10 3 Device Management EE Device Management Access C Add New Device Add New BEACon Set Time Upgrade Firmware Get Challenge Code Set Challenge Code Site Key Setting Device management menu on menu bar supports following functions Add New Devices Add New BEACon Set Time Upgrade Firmware Get Challenge Code Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 10 3 1 10 3 2 Set Challenge Code Site Key Setting 280 For detailed setting as to add new device add new controller import factory password code factory password password initialization refer to chapter 6 device management Time setting Device Management Access Add New Device Add New BEACon Upgrade Firmware Get Challenge Code Set Challenge Code Site Key Setting You can synchronize the time of all of the networked BioEntry to the time of host PC If you already checked on the Synchronize current PC time at startup check box which is on Options
197. r decision which will be asked waming message whether it will convert to new Access Control format or not You can set up a door zone combining multiple BioEntry devices Enter the name of the door zone Check on the target BioEntry devices and click the lt lt button Door Zone Definition Door Zone List Reserved Door Zone New Door Zone 943 New BioEntry 1 1539 New BioStation O11050 New BioEntry Cancel Press the OK button to add the door zone on the door zone list 6 5 Access Group setting As you seen in 6 4 Door Zone Setting there are previous and new method for access group setting Previous Method By combining time zone and door zone you can designate an access group With this access group you can restrict the user s right to access Press the Add New Access Group button Enter the name of access group Check on the time zone and door zone and press the lt lt button Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 243 Access Group Definition Access Group Name New Access Group Time Zone Time Zone List Reserved New Time Zone Door Zone Door Zone List Reserved New Door Zone Press the OK button to add the selected access group to the access group list You can apply this access group to users on the 3 User Management menu New Method Copyri
198. r use Door Open Alarm sec Enter the time to determine whether entrance door is open for a long time Driven By Select an event when an entrance door is open for a time longer than the set Long Time Door Open setting Lock Time Set the time when a designated entrance door is always closed as an item inter working with the entrance exit time set in entrance control item Unlock Time Set the time when a designated entrance door is always opened http www supremainc com BioAdmin User Manual 199 as an item inter working with the entrance exit time set in entrance control item Anti passback Set whether to apply anti passback between Outside and Inside device Soft Make a record and allow entrance in case of not verifying APB Hard Not allow record and entrance in case of not verifying APB Reset Time Make clearing entrance limit time against APB limit 4 7 7 I O Setting Window to set I O terminals as use s discretion besides door BioAdmin Software DER System User Management Device Management Access Control Device Management Device Configuration Task aa Device Info ee Device Name 1058 New BioEntry Plus Device ID 1058 a Add New BEACon BH Remove Device Device Type BioEntry Plus Firmware Version 1 0_071009 Check Status bakes Operation Made Network Setting Entrance limit Setting Door Setting I O Setting Command Card Wiegand
199. r uses a encrypted communication with BioAdmin Client and BioStation by using SSL authentication Encrypting the communication between Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 28 BioAdmin Server and BioAdmin Client or BioStation enables much more secure solution to protect the information Designate the OpenSSL path By default you can find the file on the following directory If it is installed in any other directory click the Browse and designate the correct directory Default directory of the openssl exe C OpenSSL bin openssl exe Pass Phrase is required to issue the certificate You should enter more than 8 digits combination of English number or special character To make the system secure you are strongly recommended to change the Pass Phrase upon the initial installation of BioAdmin Server Change Pass Phrase New Pass Phrase ie Confirm If you change this Pass Phrase while using the BioAdmin Server after the installation you should conduct the following procedures Change the SSL option of the connected BioStations as Not Use Stop the BioAdmin Server Change the Pass Phrase Start the BioAdmin Server Issue the SSL certificate for BioStation If you are using BioAdmin Client select the BioStation and press the right button of the mouse Select Authenticate Device Ifthe certificate is issued properly and stored on the BioStation BioStatio
200. rd Read Card Write Card Format Card Verification Test Input the second fingerprint information in the same way as the process of first fingerprint information input Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 68 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Use Device as Enroll Station Device ID 2686 New BioStation Wiegand Card ID Setup 1st Template C Duress e NENON SANA Gel Ee et UI EE 44 d ad EE ef a SC E 2nd Template C Duress y aN KM a oi Set 1 1 Security Level BioStation BioEntry Plus Device Default v BioEntry Smart Pass Device Default v Smart Card AF ID Smart Card S N S N 0 RF 000 0 User ID n D n NN LEA AA AGE 6 of oo e pe LRE aa Oe te d E UserlD 853 T A d date SAS ei Ee LOLS SL Oe oof ter A A P A wie Dr D Dr DD Dr D Dr D NS gar eee e Dr Dr D D Eales ff E PE AA wegen af eer e eier e C Bypass Card Aa Wd WRAN gg N N ct a EES fi 4 Ce Das if SE SE eA A aerer a ae AA pote SPAS foe NN a ae A decal el atl Oe ot tt ff ff ff Read Card fe fe Write Card Format Card Ce le Delete To close enroll process click OK button Then you can see enrolled user information on user list window This m
201. rd the specific Wiegand string contained in customer s ID card can be transferred to the smart card For this operation RF Wiegand device should be connected to the Wiegand input port of the selected BioEntry device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 127 Read Wiegand String Device ID 1243 New BioEntry Get Wiegand String UserID H Wiegand String C write Wiegand String As ItIs Cancel Detailed operations are as follows Press the Wiegand String Setup button Press the Get Wiegand String button and touch the ID card containing Wiegand string on the Wiegand device The Wiegand string received from the device is displayed on the user management window Enable Write Wiegand String As It is check box to use the Wiegand string instead of the user ID Press OK button to issue the user s smart card Then the received Wiegand string is stored on the smart card If the check box is disabled the Wiegand string converted from user ID is written to the smart card 3 5 9 Read issued smart card The information stored on the issued smart card can be retrieved by Read Card button on the user data information window When PC USB smart card device is used the site key management window will also appear if the site key is mismatched In reading process the site key change option is neglected 3 5 10 Card format Formatting is the process of erasing iss
202. rd KE EE 231 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 11 o AR D lio D EE e Soh ae ease trea hc ree hte fred pit eA teres ei tad ied 231 5 4 Manage SIMANCANC E 232 54T Readissued SMart Carden cei iit see ah oer aah eee desta 233 542Z Smart Gard ommatan anria AENA ANERER wieder 233 Dis EditCa rd LEE eege ees Zeg 233 5 5 1 Configuration of smartcard layout echt page EEN 234 5 5 2 Size of Fingerprint data Template EEN 235 9 59 90 BOCK s sce thea ee naan TEE O OAOT 235 E EN ie Ree EE 235 5 5 5 Factory default initial setting vote 236 E en e EE 237 6 1 ime Code SOU e SE 238 6 2 Holiday de e WEE 239 Le SEN det Et e EE 240 64 DOOr ZONE SEUNG WEE 241 6 5 Access Group setting 2 eccececsceceseeceseeeeesesecacsecaeseeecsesecacsecaesesaeseeecaseecaeeeeateneeeatees 242 He MOMONG e aa aeaa aaa ea aaa iaaea 246 K Setup ee ln e WEE 246 T220 Start Montong E a Band Sut adnan Maun Over aeaa era dita va Nuns eean ea Nal edauran ita Marcuse 247 Zoe Fa reehkerermgi Zeg ageet calito Go ue ee Gee ee 248 PAs Event ISU TOR DOOM geseet eenegen 248 LA Door Open Close oiana ashes nee avian Eeer 248 42 Alann REIGASC ics sae aon AAA A E A i seen 249 S E EE 250 8 1 Configuration of Log Check page c dcc aac ed ad ee 250 8 2 Manage Log database eiert eet A eee GN Ane ee eee 251 8 2 Ee e CN 251 8 2 2 Auto uploading Seuing EE 251 8 2 3 Release auto uploedmg AEN
203. re defined Time Zone of Access Control at main menu Please refer to 6 1 Time Zone Setting Time Zone should be transferred to all devices to select in 1 1 operation mode Default is Always or No Time Always can be selected only one in below ID Fingerprint ID Password ID Fingerprint or Password Card Only 1 1 Operation Mode ID Fingerprint ID Password ID Fingerprint or Password Card Only No Time No Time i Always v No Time v 1 N Operation Mode in 1 N Operation mode user is authorized by fingerprint without user ID input About how to start fingerprint input user can choose one of 3 modes i e auto OK button Function Key and none Auto mode Because BioStation sensor is always on as standby mode scan starts right after a finger is placed on the sensor Ifyou choose OK button or Function Key button mode you have to place a finger after pressing OK button or Function Key button on BioStation when entering fingerprint Incase of not using 1 N mode but using 1 1 mode only choose None mode Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 162 1 N Identification Auto v 1 N Schedule Always Function Key Function Key J T amp A Mode Not Use J Double Mode No Time v 1 N Schedule Select time zone of 1 N Operation mode which can be also assigned by pre def
204. ress the Add New Holiday button Press the Edit Code list in Holiday Setting window Holiday Setting ania New Holiday List w10 19 2007 4 Del All Friday October 19 200 w C Yealy Repeat Days Long Enter the name of Holiday Group Enter the date to be grouped as a holiday group and click Add button At the moment it is also possible to designate period or repeat depending on the date option Enter the number of days to enter However the max number of items may not be larger than 32 In the case holiday group should be additionally created Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 6 3 TEA Rule Group Name Daily Rule Sunday Monday Tuesday Wednesday Thursday Friday Saturday Holiday Setting Holiday Schedule Holiday Group Holiday Group Monthly Schedule C Setas default Save Close Time zone setting Copyright 2007 by Suprema Inc New T amp A rule group 2 240 After completing the addition of holiday click OK button The generated Holiday list can be used for Time amp Attendance Report New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Attencance Code New Holiday List Not Use New monthly schedule
205. right 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 89 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information User ID Edit Private Information Name Company Department Title Details Access Group Phone Status Active Mobile Group 1 Full Access E Mail Group 2 None Gender Male v Group 3 None Date of Bith 10 16 2007 wi Group 4 None Start Date 1 1 1970 e Entrance Limitation BioStation Expiry Date 12 31 2030 el Daily Limit 0 00 23 59 Timed APB Minute Other Information Password BST Admin Leve Normal User Enter the user information on the User Information tab Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 90 User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Basic Personal Information User ID 853 Edit Private Information Name Dongsuk Suh Company Suprema Department R amp D Title Manager Details Access Group Phone 012 345 6789 Status Active Mobile 098 765 4321 Group Full Access E Mail dsuck anymail Group 2 None Gender Male v Group 3 Date of Birth 6 14 1970 v Group 4 None
206. rs select users whose user information in BioAdmin software doesn t correspond to user information uploaded from device Check new users select users who are enrolled in device only but do not exist in BioAdmin software Delete all to delete selected users and the other all users Hide same users If you press check same users checkbox of a user whose data is same both in device and host PC is checked If you display hide same users these users can be hidden on finger scan information window Get access group data Check a checkbox of get access group data and execute Get from device to upload user access group information Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 132 3 10 Synchronize all users Synchronization all users button transfers all user data base in host PC to device and surplus users remaining in device only are deleted User information such as user ID fingerprint information access group number and security level is uploaded thru this process Select a Device Me AI Devices MB BioAdmin Server ME 1334 New BioStation Me 192 169 1 254 MEG 254 New BEACon Me 943 New BioEntry ME 1050 New BioEntry Me 192 168 1 74 MINE 1539 New BioStation Transfer all users to device and delete redundant users in device only Detailed operating process is as follows Press synchronize all users button Select applicable device on device list
207. ryption Strength WER Netwo rk Key MH Confi rm Key sasnsonosnnnnnannnnnnnnnnn Preset Name preset name is displayed on the BioStaiton using WLAN setting ESSID ESSID is the unique ID of the access point To check the ESSID of your access point refer to the manual of your access point or ask your network administrator Auth mode You can select the network authentication open system shared key and WPA PSK It must have same setting to authentication of access point You can see this setting on security page in access point setup application Encryption Strength You can select the encryption strength between WEP Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 167 and WPA PSK By selecting WEP or WPA PSK you can encrypt the communication data between access point and BioStation If the BioStation is too far from the access point or there is an obstacle between BioStation and access point the network can be interrupted Also the wireless network may not be successful due to the unique characteristics of the access point Thus it is highly recommended to have another network method rather than wireless LAN TCP IP Get IP address by DHCP Use Dynamic IP address Set IP address manually Use Static IP address In BioStation settings choose whether to get IP address automatically or set manually In case that IP address is automatically assigned to DHCP in BioSt
208. s Verify Success Low ms Verity Fail Identify Success v Count Output 1 Disabled Enabled Event Delay ms 0 Enroll Success D Verify Success BA 7 High 100 Enroll Fail E verify Fail gedet Be Delete Success E Identify Success Lowims 0 Delete Fail Identify Fail Identify Not Granted v verify Duress v Count 1 Apply Apply to Others Setto Default Configuration of input port To define the configuration of input port function and minimum duration should be specified Function means what to do when the input port is activated and minimum duration means the required duration of pulse to activate the input port Description of Input functions Function Description No Action Disable input port Enroll by Scan initiate enrollment using finger scan Identify by Scan initiate identification using finger scan Delete by Scan delete user by identifying input finger Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 212 Delete Alll delete all user data Enroll by Wiegand ID enroll by scan with user ID received at Wiegand input port Verify by Wiegand ID initiate verification using finger scan with user ID received at Wiegand input port Delete by Wiegand ID delete user with user ID received at Wiegand input port Controller Reject input for reject signal from controller Controller Accept input for accept signal from controller
209. s Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Delete All Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success Enroll Success User ID User Name D Nakwon Lee ChangGyun Lee Hoyoung Gyo Gunsaeng Shin Hyunbok Jeon Bohyun Gha Ilhwan Gang Gyunghun Hong Jonguk Hwang Dongsuk Suh Nakwon Lee ChangGyun Lee Hoyoung Gyo Gunsaeng Shin Hyunbok Jeon Bohyun Gha Tlhwan Gang Gyunghun Hong Suprema Inc Source BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation BioStation 254 v In case of pressing upload all logs button select device window appears and all logs of device selected here are uploaded In case partial log information remains in BioAdmin existing log information is kept as it is and new log information is uploaded Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 255 Select a Device Me AI Devices MB BioAdmin Server ME 1334 New BioStation Me 192 169 1 254 MEG 254 New BEACon Me 943 New BioEntry ME 1050 New BioEntry Me 192 168 1
210. s identification can be done in less than one second BioStation is the access control and time attendance finger terminal of distinguished performance Multifunctional fingerprint terminal for access control and time and attendance BioStation provides various information real time adopting 2 5 inch color LCD and high quality sound Also using wireless LAN or USB memory you can configure network and transfer data without complicated wiring BioEntry and BioStation supports various fingerprint sensors i e Optical semiconductor type capacitive type or scan type swipe thermal type Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 5 enabling a user to utilize an optimum fingerprint sensor fit for the application system About Suprema Inc Suprema is a leading biometric company offering core fingerprint technologies in various applications Suprema s fingerprint products include access control systems time attendance system low cost standalone OEM modules USB fingerprint scanners and fingerprint algorithm SDK Suprema s fingerprint recognition algorithm was proved to be the world top level by ranking first in the 3rd international Fingerprint Verification Competition FVC2004 amp FVC2006 with the lowest error rate in light category Suprema s fingerprint products have been sold to more than 80 different countries and are being used in various applications For more information on Suprema
211. sable v Unlock Time None Relay on Ki Relayof Refresh Apply to Others Sette Defaut Fingerprint Security Level Normal Image Quality Normal v Sensitivity 7 Max v 1 N Delay 2 sec v Chk Duplicate FP Disable v Security level Suprema Inc Fast Mode Auto v View Image Yes v Scan Timeout 10 v Matching 3 v Security level can be chosen among normal secure and most secure Internally security level adjusts FAR False Acceptance Ratio As FAR and FRR False Rejection Ratio are in inverse proportion to each other the higher security level is the more FRR increases so does FRR Default is normal Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 173 Image quality Decide standards by which the quality of input fingerprint image is over certain level You can choose from weak normal and strict Default is normal Sensitivity Sensitivity decides sensitivity of detecting a finger In high sensitivity finger input is accepted more easily but if sensitivity is lowered input fingerprint image gets more stable as fingerprint is captured only when fingerprint covers more than a certain part of a finger In case of optical model sensitivity can be moderated by lowering setting of sensitivity against the rays of the sun Default is 7 Max 1 N Delay Interval Time to take 2
212. ser Manual 251 shown Task box Task box includes buttons to control basic operations of the Log List page 8 2 Manage Log database 8 2 1 Get recent logs In case of pressing get recent logs auto upload button window for select device pops up and as to selected device here log information newly generated after log information in BioAdmin is uploaded For the BioStation connected to BioAdmin Server you do not need to get logs from them because logs will be automatically saved on BioAdmin Server on real time Select a Device I All Devices COMB BioAdmin Server CIS 1334 New BioStation CTS 192 169 1 254 CIR 254 New BEACon OE 943 New BioEntry D 1050 New BioEntry CTS 192 168 1 74 CR 1539 New BioStation Auto Uploading NotUse O15min O30min O 60min 8 2 2 Auto uploading setting In case of pressing get recent logs auto upload button log information generated in BioEntry and BioStation for set period can be uploaded automatically to BioAdmin Administrator can execute auto uploading by choosing 15 min 30 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 252 min 60 min according to applied environment Select a Device Me A Devices MB BioAdmin Server MME 1334 New BioStation Me 192 168 1 254 MSS 254 New BEACon MOS 943 New BioEntry MS 1050 New BioEntry Mie 192 168 1 74 KR 1539 New BioStation J Auto Uploading NotUse QO15
213. soft OLE DB Provider For Data Mining Services Microsoft OLE DB Provider for Indexing Service Microsoft OLE DB Provider for Internet Publishing Microsoft OLE DB Provider for ODBC Drivers Microsoft OLE DB Provider for OLAP Services 8 0 Microsoft OLE DB Provider for Oracle Microsoft OLE DB Provider for Outlook Search Microsoft OLE DB Provider for SOL Server Microsoft OLE DB Simple Provider MSDataShape OLE DB Provider for Microsoft Directory Services Select data source name Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 35 Data Link Properties Provider Connection Advanced All Specify the following to connect to ODBC data 1 Specify the source of data Use data source name OF dBASE Files Excel Files MS Access Database 2 Enter information to log on to the server User name Password C Blank password _ Allow saving password 3 Enter the initial catalog to use Test Connection Enter the ID and password of the DB server It there is no password designated check on the Blank password If there is any password check on the Allow saving password Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual E Data Link Properties Provider Connection Advanced All 36 Specify the following to connect to ODBC data 1 Specify the source of data
214. ssword Auth Limit means the number of access that the user is allowed in a day from 00 00 to 24 00 of the day If you do not want to restrict the number of access for a user leave this menu as the default 0 Timed means the minimum time interval required for access of the same user If you set this menu as 5 that user will not be able to enter the door again within 5 minutes Other Information The Password on this menu is required when the BioStation requires the Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 120 user s password Also users should enter this password when they log in to the BioAdmin Client to check their log information BioStation admin level On this menu you can select the user as an administrator for BioStation terminal Note in user information user ID should be entered as it s a required field but the rest fields can be left blank 3 5 2 Custom field You can add customized user information columns on the user management window by designating required fields on the Custom Fields menu Customize button enables the pop up window to add the customized user information column After filling out the required contents press the OK button User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Fax 031 4567 8562 IP Addr 123 123 121 Room No A Memorial Day 6 14 2007 Married C Car Co
215. t Relay 1 Di Relay On Relay Off Door 1 Unlock Setting Unlock Duration 3000 O ms Not Use Alarm ON Event C C Alarm OFF Event fees L Detailed Operations are as follows Select a relay to set up the configuration Once you select a relay applicable items for the selected relay will be activated on the relay setting window You can also open close the relays by pressing the Relay On Relay Off buttons Relay Select Relay 1 si Relay On Relay Off Unlock Setting Enter the unlock duration time Once the door is unlocked it can be locked again after this unlock duration time Door 1 Unlock Setting Unlock Duration 3000 ms Alarm On Event Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 227 Select alarm on events on the drag down menu by checking on the Set Event check box Enter High Low and Count to set up the alarm frequency If any of the alarm on events is triggered the alarm will be activated at your designated frequency Alarm ON Event Event Grant Device 1 v C Set Event High ms Low ms Count 0 Alarm Off Event Select alarm off events You can enable the alarm off events simply by double clicking the events on the disabled event list If any of the alarm off events is triggered the alarm will be deactivated regardless of remaining duration or pulse counts Alarm OFF Event Disabled i Enabled
216. t button on main menu and select Manage users in device on task window Once device is selected fingerprint information such as user ID number of fingerprint access group security level and Check to select is displayed Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 101 Select Target Device Device List Template Information WI Devices User ID Number of T Access Grou Security Level Check COMI 7 TEE Check All ll Uncheck All Check Reverse Delete Selected users Check Same Users Check Ditferent Users Check New Users i Delete All Users Hide Same Users Templates 0 0 Get Access Group Data Get from Device Close 2 4 3 Step 3 Enroll user Select the User Management menu then the user management page appears on the main window A BioAdmin Software System User Management Device Management Access Control User Management User Management Task El User ID UserName Company Department Template Num Active ER Add New User There are no items to show ER Delete Checked Users Bn Transfer checked users to device D I Delete Checked Users from Device GO Manage Users in Device Synchronize All Users IS Export to File RA Import From File Selection Tool Check All Uncheck All Check Reverse Check Selected Users Uncheck Selected Users W Suprema Inc Copyright 2007 by Supre
217. t to place in a correct position 1 3 2 How to place a finger on a sensor 1 Place a finger as it completely covers the sensor with maximum contact 2 Itis better to place the core part of a fingerprint to the center of a sensor People usually tend to place only the top end of a finger Where is the core center of a fingerprint A peak where spirals of fingerprint ridges are dense Usually opposite to lower part of a nail Itis recommended to place a finger as the lower part of a nail is located at the center of a sensor Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 18 3 If a finger is placed as in the right picture only a small area of a finger is captured So it is recommended to place a finger as in the left picture 1 3 3 Tips for different finger conditions Suprema s fingerprint products are designed to scan fingerprint smoothly regardless of the conditions of a finger skin However if a fingerprint is difficult to scan due to other influences please refer to the followings tips 1 Ifa finger is stained with sweat or water scan after wiping moisture off 2 Ifa finger is covered with dust or impurities scan after wiping them off 3 Ifa finger is way too dry scan after blowing warm breath on a fingertip 1 3 4 Advices on fingerprint enrollment 1 In fingerprint recognition enrollment process is very important Therefore when enrolling a fingerpr
218. ta from BioStation you may not control the BioStation from BioAdmin Client Check Server Status If you finished the installation of BioAdmin Server and BioAdmin Client you can check the server status on BioAdmin Server Config window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 46 BioAdmin Server Config Status ei 3ioAdmin Server 4 2 192 168 1 120 Running Connection fi TCP Port 1480 Max Connection Database u Database Type SQL Server SaL Connection String Provider SQLOLEDB 1 Persist Security Info False UserlD sa Data Source BIOADMIN 50PM34 OpenSSL Path C Open SL bin openssl exe Pass Phrase eeccccce Check the version and status of the BioAdmin Server Enter the server IP and server port on BioAdmin Client You can check the connection status by pressing Test button Connect Server Server IP 192 168 Server 1480 Connected to server Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 47 1 5 1 5 1 1 5 2 f you can access to the BioAdmin Server now you are ready to use the BioAdmin Server and BioAdmin Client Note In case of installed BioAdmin Server successfully it may occur not to connect to server correctly Please restart BioAdmin Server program You may go to Windows Start gt Program gt BioAdmin Serv
219. teps for LED and Beep is similar to output port configuration Additional events are selectable listed as Event Description when to activate the output port Enroll Wait Finger When the device is waiting for a finger scan to enroll Enroll Processing When the device is in enrollment process Identify Wait Finger When the device is waiting for a finger scan to identify Identify Processing When the device is in identification process Verify Wait Finger When the device is waiting for a finger scan to verify Verify Processing When the device is in verification process Delete Wait Finger When the device is waiting for a finger scan to delete Description of default LED Beep configuration By factory default various output patterns are defined for LED and beep to show current status and processing result The description of default LED Beep configuration is listed as follows Events LED Beep Enroll Wait Finger Slow blinking amber None Verify Wait Finger Fast blinking amber None Identify Wait Finger Slow blinking amber None Delete Wait Finger Fast blinking amber None Enroll Processing Steady amber None Identify Processing Verify Processing Enroll Success Steady green One beep sound Verify Success Identify Success Delete Success Command Card Success Verify Duress Identify Duress Enroll Fail Steady red Three short beep sounds Verify Fail Identify Fail
220. ting Use DHCP select Not use DHCP Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 195 Set the IP address gateway subnet mask and port as proper values Port default 1471 is operated as a server port if it uses server Server Setting It shows whether the BioEntry Plus is connected to server If connecting BioEntry Plus that is connected to general TCP IP nota server to server check Use and set the server IP address and the server port As such if connected to a server the BioEntry Plus is connected to it and disconnected from the TCP IP immediately It may take a time until it is reconnected to the server again If the communication status of BioEntry Plus connected to the server is not good click the right mouse button on BioAdmin Server server and try to reconnect to server RS485 Use for RS 485 communication of BioStatiobn In RS 485 mode the connected devices take a role as Host and Slave Suprema s new total integrated system including BioStation BioEntry Plus and Secure I O is consist of 1 host device 1 slave device and max 4 Secure I O Host device has total 10 relay and 20 inout Please refer to the Secure I O Installation Guide and 4 5 3 Network Setting of BioStation in this manual for further information Mode PC Connection Host Slave None Baudrate Slave Device SIO default Setting Copyright 2007 by Suprema
221. tree window Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 56 E Di All Devices EI L BioAdmin Server SE 2686 New BioStation 3 192 168 1 77 TEE Se 192 168 1 254 E 1 New BEACon 42965 New BioEntry 42714 New BioEntry Select user management button on main menu and select Manage users in device on task window Once device is selected fingerprint information such as user ID number of fingerprint access group security level and select is displayed Select Target Device Device List Template Information All Devices User ID i Check FF 192 168 1 77 o jevice D Different Bioadmin Server EH W 2886 New Biostation E 192 168 1 254 S 1 New BEACon 42965 New BioEntry 42714 New BioEntry Check all Uncheck All Check Reverse Delete Selected Users Check Same Users Check Different Users Check New Users Delete All Users Users 3 Hide Same Users Templates 3 6 Getfrom Device Close 2 1 3 Step 3 Connect device Select Device Management menu to display device management page on main window BioAdmin software network setup is divided into network serial port and USB connection Change settings and apply them to device Network setup is to designate settings for local and wireless network connection Copyright 2007 by Suprema Inc http www supremainc
222. ty level and all time pass card Bypass setting ENEE 125 3 5 8 Wiegand string setting USING ID can ENEE 126 3 5 9 Read issued smartcard nisitan ieii ia Naia a naia 127 3 5 10 Card hue EE 127 3 5 11 Notes on card ISSUC oer dEr Eaa ANENE EEE ANNE AANEREN ia 127 3 5 12 Rules on user T amp A event contre 128 Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 9 3 6 Delete checked user 128 3 6 1 Delete checked user from BioAdmin software A 128 3 6 2 Synchronization deleted user information With COVICC 0 ENEE 128 3 7 Transfer checked user tO device eene 128 3 8 Delete checked users from device A 130 3 9 Manage users in device si acccsicictiieieadi lata dni ad et An alee ie 130 3 10 e ler 132 3 11 Exp rtto UE 132 3 12 IMporttrom fle iss anna a e a Eed Ve sde EE 134 4 Device Management cccscesceseseetceseseesteseseesesseteesesseseeeeneeseeseeseeeeseeneeseeease 137 4 1 Search New device A 138 AVA 7 DOMAl e EE 138 4 12 SEUNG TEE 140 4 13 USB devige hniena ne aaae EENS EES 141 4 1 4 Virtual Terminal E 141 4 1 5 UDP BioEntry ES ee 143 427 Add New BEACON EE 147 4 3 Remove device AAA 148 AA JLISUWINGOW enee See 149 GE le e 149 APA 2 ZOMG EE ras dante EE 150 4 5 Manage BioStation device EE 158 4 5 1 Device information EE 160 4 5 2 Operation Mode teini Ae 160 4 5 3 gt NGWORK ul e EE 164 4 5 4 FUNCHON ke ergi entre eege A ere Eeer 170 4 5 5 Devi
223. ual 115 company dept on user list window User Management bi User ID l User Name Company Deparment Title Template N Active d 853 Dongsuk Suh Suprema Manager 2 oO Nakwon Lee Suprema 2 Y g 934 ChangGyun Lee Suprema Mat Manager 2 Y g 1144 Hoyoung Gyou Suprema R amp D Engineer 2 Template N Active Columns a Y Arrange By gt Sort scending Sort Descending Group by this Field Group by Box Remove Column Field Chooser Alignment gt Best Fit lt lt lt lt lt lt lt lt lt Press the Columns button and check on your required columns to show them on the user list Company Template N Active Check User ID User Name Arrange By gt Suprema Suprema Suprema Sort Ascending Sort Descending Company Brann bis thia Clala Nanartrnant Press the Arrange By button and select your required columns to array the user list by your selected column Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 116 Active Yy Title Check Sort Ascending User ID User Name Template N Sor Descending Group by this Field Group by Box Company Department Titla m ma Press the Sort Ascending button to array the user list in ascending order Press the Sort Descending button to array the user list in descending order
224. uch as user ID fingerprint information access group and security level is transferred through this process Check enrolled user User Management User ID User Name Company Department Title R amp D Template Num Active Dongsuk Suh Suprema Manager 2 Click transfer checked user to device check device and click ok select Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 70 button Select a Device Sat Devices MB BioAdmin Server MME 1334 New BioStation Me 192 168 1 254 IR 254 New BEACon MS 943 New BioEntry MS 1050 New BioEntry Mie 192 168 1 74 MINE 1539 New BioStation C Overwirte users with different information Press Manage users in device button and click device If user information fields are indicated in yellow it means user information has been transferred to device successfully 2 1 7 Step 7 Monitoring Select Monitoring menu to show Monitoring display on main window Select Monitoring setting menu and double click Monitoring on off To save click ok button To start monitoring for linked all BioStation devices select start monitoring Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 71 EC BioAdmin Software System User Management Device Management Access Control Monitoring Event List k dess Event Door bc Setup Monitoring Date Time Device Event T amp am
225. uck anymail Group 2 None Gender Male v Group 3 Date of Birth 6 14 1970 v Group 4 None Start Date 17 1 71970 Entrance Limitation BioStation Expiry Date 12 31 2030 e h Daily Limit 0 00 23 59 Timed APB Minute Other Information Password BST Admin Leve Normal User j Cancel Especially you can select the Company Department and Title on the drag down menu To add new Company Department or Title information press the CJ button After entering the required information press the Add button Press the Save button to save the added information Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 104 Company Name Your Company Suprema In addition to the basic user information you can add the Custom Fields to the user information If you do not need these custom fields just skip the custom fields setting To set up the custom fields press the Custom Fields tab User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule Customize Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 105 Click the Customize button Check on the required fields and enter the user information for those selected fields After entering the user information press the OK button Custom Fields Text Fields
226. udes detailed list of user database and summarized information Selection tool box Selection tool box includes buttons to select users Task box Task box includes buttons to control basic operations of the user management page User List window User list includes the following information on the users Shows basic information such as user ID name company dept position title number of enrolled fingerprint and status Double click user ID to pop up user information window User information has 4 tabs i e User information custom field fingerprint and user time attendance rule Fingerprint templates fingerprint image is never stored Note What is activation in access group setting It is used when transferring user data in host PC to device If activation is not on checked upon transferring checked in user list to device user data can t be transferred and data in device is deleted For instance when one returns to work after having been excluded from access group and inactive due to dispatch or long term leave activate him her and manage user list User List Display Setting You can customize the display of the user list Detailed operations are as follows Press the right button of your mouse on the column header of User List Note What is Column Header It is on the head of row user ID name Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Man
227. ued information on the smart card The Format Card button on the user data information window initiates formatting process The site key change option is effective in this process 3 5 11 Notes on card issue Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 128 3 5 12 3 6 3 6 1 3 6 2 3 7 Before writing on a new smartcard you should format the new smart card first Site key is not stored in BioAdmin software to improve the security of the system Note It is the necessary for the administrator to remember and keep in secret the custom site key for proper management of the system Also please pay keen attention to changing the site key on the smart card If writing to smart card is stopped accidentally in issuing process the smart card might be corrupted and irrecoverable Be careful to avoid accidental stop in writing smart card Rules on user T amp A event control This menu is used to set user time attendance rule For the detailed operation refer to Chapter 12 Report Delete checked user Delete checked user from BioAdmin software Delete checked user information on user list window If you check a user and click delete checked user in task box a message do you want to delete checked selected user appears If you press ok button checked user is deleted from BioAdmin of the host PC Synchronization deleted user information with device If you trans
228. utton on the main window Smart card can be issues by two methods Issuing with PC USB smart card device Issuing with BioEntry Smart connected with host PC To use a BioEntry Smart as a card issuer enable the Use BioEntry as Enroll Station check box and select a device ID Otherwise PC USB device is used as a card issuer Issue with PC USB smart card device Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 125 3 5 6 3 5 7 Place the target smart card on the PC smart card device Press the Write button to initiate issuing The site key management window will appear at the first trial of issuing after starting of BioAdmin software Also the window will appear if it fails to access the smart card due to the mismatch of the site key Type the current site key to access the smart card If it remains blank BioAdmin software uses default key OxFFFFFFFFFFFF as a current site key If it is desired to change the site key on issuing enable the Change Site Key check box and type new site key Then new site key is updated on the smart card The new site key should be correspondent with the site key on BioEntry Smart device Issue with BioEntry Smart Place the target smart card at selected BioEntry Smart Press the Write button to initiate issuing Since the site key management information is stored on BioEntry issuing is processed without requesting site key User securit
229. vel BioStation BioEntry Plus Device Default v Device ID 2688 New BioStation v Wiegand Card ID Setup BioEntry Smart Pass Device Default v 1st Template 2nd Template C Duress C Duress Smart Card RF ID Smart Card S N S N 0 RF 000 0 User ID UserlD 853 aN aN RB ees eee Bi fe I Ar AF oe ee No SA dE d CS Pd hle ZZ d d Ae eieiei eieiei ee d EE SS RN Bae fff A fete ei ei ei d eA CaS E Y E Cen Dn Dn D D vat Li SOE od EREEREER SERERA Lift tse ff fees A T e E A ee ih ieee d NM 2 E t Zo 2 A Al ey z 7 d d H i gar eee e Dr Dr D D teg af eer e eier e C Bypass Card On Gp na a E LAARA fe fe e SE E E ct a EES SE erte ar LA of rrr SAAS Cote E ff a tt ff ff ft rr Press the OK button to complete the registration process Then you can see the information on the registered user on the user list window It means that the user s information is added to the database on host PC User Management User ID User Name Company Department Title Template Num Active Dongsuk Suh Suprema R amp D Manager Step 4 Enroll user with transfer checked user to device menu Transfer to Device is used to transfer the user database of the host PC to BioEntry devices The user information such as User ID templates
230. vider for Indexing Service Microsoft OLE DB Provider for Internet Publishing Microsoft OLE DB Provider for ODBC Drivers Microsoft OLE DB Provider for OLAP Services 8 0 Microsoft OLE DB Provider for Oracle Microsoft OLE DB Provider for Outlook Search Microsoft OLE DB Provider for SQL Server Microsoft OLE DB Simple Provider MSDataShape OLE DB Provider for Microsoft Directory Services Enter the SQL Server name Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 41 Data Link Properties Provider Connection Advanced All Specify the following to connect to SOL Server data 1 Select or enter a server name BIOADMIN 5OPM35 User name 2 Enter information to log on to the server Use Windows NT Integrated security Use a specific user name and password a Blank password E Allow saving password 3 Select the database on the server Attach a database file as a database name Test Connection Enter the User name and Password for the database server If there is no password check on the Blank password If there is any password check on the Allow saving password Choose the Select the database on the server To select this option you should create the database in advance on the SQL Server Press Test Connection button to check the connection status Press OK button Co
231. www supremainc com BioAdmin User Manual 283 SecondaryKey Change Change Secondary Key Current Primary Key New Secondary Key C Retype Secondary Key Change Site Key Option C Use Secondary Key Auto Update Key Options You can also change the key options only In this case you only have to enter the current primary key with the options Site Key Options Change Site Key Option Current Primary Key C Use Secondary Key Auto Update 10 4 Access Control gd Access Control Time Code Definition Holiday Definition Time Zone Definition Door Zone Definition Access Group Definition Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual 284 Access control menu on menu bar supports following functions Time Code Definition Holiday Setting Time Zone Setting Door Zone Setting Access Group Setting For detailed setting refer to chapter 8 access control Contact Information Suprema Inc 16F Parkview Office Tower Jeongja dong Bundang Seongnam Gyeonggi Korea Tel 82 31 783 4502 Fax 82 31 783 4503 Website http Awww supremainc com Sales inquiry sales supremainc com Technical inquiry support supremainc com Copyright 2007 by Suprema Inc http www supremainc com
232. y level and all time pass card Bypass setting On issuing security level can be specified for each user By changing Security Level dropdown list user s security level can be specified from 1 1 000 to 1 100 000 000 If Device Default is selected security level configured on BioEntry Smart device is used To issue all time pass card bypass card you can choose bypass card option Note What is bypass card Device authorizes a user with a card without fingerprint authentication process Copyright 2007 by Suprema Inc http www supremainc com BioAdmin User Manual User Data Information User Information Custom Fields Fingerprint User Time Attendance Rule oat Device ID 3143 New BioStation ze Wiegand AF ID Setup 1st Template 2nd Template C Duress C Duress aaa ono Se eee tt ee a aa aa aa aa Ee e Sf ee E De Del E ee een Geelen NN fF eegenen bw Su oe ttf PRRP PRA PPRPP d of of Ot ft ff GO E tt gll d f f l f H H CD Dr D D D p Dean D D s Dee N Ce D n SS N SE e BS ee KR e HB I Sarre aed eee al a L Es CN x Ger kg S 3 5 8 Wiegand string setting using ID card 126 1 1 Security Level BioStation Device Default BioEntry Device Default Smart Card AF ID Smartcard S N S N 0 RF 000 0 User ID UserlD 853 C Bypass Card Verification Test On issuing a smart ca
Download Pdf Manuals
Related Search
Related Contents
COMET 2 - Marco Beverage Systems Tobii T60 XL Eye Tracker Scanner Central Admin 4.6 Guida dell`utente SONOKIT de 2 pistas Massive Wall light 17000/30/10 9000X Series Drives Option Board 品質保証書 取扱説明書 窓口用 インターホン SD BRITE III Remote - ADB Airfield Solutions SmartXS Installation Guide Copyright © All rights reserved.