Home
pickering
Contents
1. 150 9002 Reg No FM38792 COPYRIGHT 2007 PICKERING INTERFACES RIGHTS RESERVED No part of this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pickering Interfaces Technical details contained within this publication are subject to change without notice Page ii SHIELDED REED RELAY MODULES 40 120 125 EEE TECHNICAL SUPPORT For Technical Support please contact Pickering Interfaces either by phone fax the website or via e mail WARRANTY All products manufactured by Pickering Interfaces are warranted against defective materials and workmanship for a period of two years excluding PXI chassis from the date of delivery to the original purchaser Any product found to be defective within this period will at the discretion of Pickering Interfaces be repaired or replaced Products serviced and repaired outside of the warranty period are warranted for ninety days Extended warranty and service are available Please contact Pickering Interfaces by phone fax the website or via e mail ENVIRONMENTAL POLICY Pickering Interfaces operates under an environmental management system similar to ISO 14001 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment Pickering Interfaces aims to design and operate products in a way that protects the enviro
2. Page 8 2 SHIELDED REED RELAY MODULES 40 120 125 pickering LL SECTION 8 PARTS LIST 619 RL2 RL3 RL4 L E TL d C23 RL5 RL6 RL7 RL8 oo RL9 RL10 RL11 RL12 gt CI oo pes C13 C11 00 C20 C12 Ki RL18 RL19 ABCABCABCABCABCABC LILIT TT RL22 RL23 ABCABCABCABCABCABC EF PTE RL26 RL27 ABCABCABCABCABCABC RL30 RL31 RL32 C21 ABCABCABCABCABCABC E AAA EET pickering Oe Figure 8 1 Reed Relay Module 40 120 125 Component Layout SHIELDED REED RELAY MODULES 40 120 125 Page 8 3 SECTION 8 PARTS LIST Pickering L THIS PAGE INTENTIONALLY BLANK Page 8 4 SHIELDED REED RELAY MODULES 40 120 125 pickering SECTION 9 WARNINGS AND CAUTIONS WARNING DANGER OF ELECTRIC SHOCK THIS MODULE MAY CONTAIN HAZARDOUS VOLTAGES BEFORE REMOVING THE MODULE FROM THE RACK REMOVE ALL SUPPLIES CAUTION Handling of Electrostatic Sensitive Semiconductor Devices Certain semiconductor devices used in the equipment are liable to damage due to static voltage Observe the following precautions when handling these devices in their unterminated state or sub units containing these devices 1 Persons removing sub units from an equipment using these devices must be earthed by a wrist strap and a resistor at the point provided on the equipment 2 Soldering irons used during the repair operations must be low voltage types with earthed tips and isolated from the main
3. This manual is available on the Pickering Interfaces website at http www pickeringtest com SHIELDED REED RELAY MODULES 40 120 125 Pages SECTION4 PROGRAMMING _______________ piekering L THIS PAGE INTENTIONALLY BLANK Page 4 2 SHIELDED REED RELAY MODULES 40 120 125 pickering SECTION 5 PIN OUTS SECTION 5 CONNECTOR PIN OUTS Figures 5 1 and 5 2 provide pin outs for the Matrix Modules in the 40 120 125 model range A1 C1 B1 S1 A2 C2 B2 52 C3 B3 83 4 4 4 54 5 5 5 S5 A6 C6 B6 S6 A7 C7 B7 S7 A8 C8 B8 S8 A9 C9 B9 S9 A10 C10 B10 10 A11 C11 B11 S11 A12 C12 B12 12 A13 C13 B13 513 14 14 14 514 15 15 15 15 A16 B16 C16 16 40 120 021 Figure 5 1 Reed Relay Module 40 120 Pin Outs SHIELDED REED RELAY MODULES 40 120 125 Page 5 1 SECTION 5 PIN OUTS Pickering L A 1 1 49 10 C1 1 51 50 2 S 21 851 5 2 1 52 52 4 52 A3 1 853 5 1 53 54 60 53 A41 55 z C4 1 54 56 54 A51 57 9 5 1 55 8 0 55 A6 1 5911 6 1 56 60120 56 A7 1 6113 C7 1 57 6214 57 A81 15 C8 1 58 6416 58 A9 1 65170 9 1 59 66 18 59 10 1 O 67190 10 1 510 68 20 510 111 69 21 C11 1 511 7022 511 121 071230 12 1 512 7224 S12 A131 e 73259 13 1 513 67426 9 513 141 7527 14 1 514 76230 514 A15 1 77 29
4. 15 1 515 73300 515 A16 1 7931 C16 1 516 30320 516 A17 1 O 81330 C17 1 517 8234 S17 18 1 83350 C18 1 518 68436 518 19 1 685357 C19 1 519 68638 9 519 20 1 87390 C20 1 S20 33400 520 A21 1 89410 C21 1 521 042 521 A22 1 O 91430 C22 1 522 244 S22 A23 1 O 93450 23 1 523 69446 9 S23 A24 1 9547 C24 1 524 O 06430 524 40 125 021 40 125 121 Figure 5 2 Reed Relay Module 40 125 021 121 Pin Outs Page 5 2 SHIELDED REED RELAY MODULES 40 120 125 pickenng SECTION 6 TROUBLESHOOTING SECTION 6 TROUBLESHOOTING INSTALLATION PROBLEMS The Plug amp Play functionality of Pickering switch cards generally ensures trouble free installation If you do experience any installation problems you should first ensure that all cards are properly seated in their slots Improperly mated cards may go undetected by the operating system or may be detected as a card of an unknown type They can also cause the computer to freeze at various stages in the boot sequence If your system employs MXI 3 you should check the integrity of all MXI 3 links When the system is powered up and during Windows start up you should expect to see periodic activity on the MXI 3 RX TX yellow indicators clearing to leave only the PWR LNK green LEDs illuminated The RX TX indicators should show activity when you attempt to access a card DIAGNOSTIC
5. PCI BUS CONNECTOR TERMINATING RESISTORS R4 TO R15 MODULE CONFIGURATION U7 Figure 7 1 Reed Relay Module 40 120 125 Functional Block Diagram Page 7 2 SHIELDED REED RELAY MODULES 40 120 125 pickering Ll SECTION 8 PARTS LIST SECTION 8 PARTS LIST The following pages provide a parts list and component layout diagram for Shielded Reed Relay Modules 40 120 125 SHIELDED REED RELAY MODULES 40 120 125 Page 8 1 SECTION 8 PARTS LIST Pickering Table 8 1 provides a parts list and Figure 8 1 a component layout diagram for the 40 120 125 Shielded Reed Relay Module TABLE 8 1 Shielded Reed Relay Module 40 120 125 Parts List R1 R2 C RS 079 RESISTOR N W 4 x 10k 1206 R3 C RS 085 RESISTOR 10k 0805 R4 to R15 C RS 102 RESISTOR N W 4 x 10R 1206 40 120 021 RL1 to 16 Spare 40 125 021 RL1 to 16 Spare 40 125 121 RL1 to 24 Spare C3 to C21 C23 C CP 034 CAPACITOR 100nF 0603 C1 C2 C22 C24 C CP 024 CAPACITOR 10uF TANT SMD C RL 089 107 1 C 12 SHIELDED C RL 015 102M 1 A 12 SHIELDED C RL 077 102M 1 A 12 SHIELDED J1 C CN 355 cPCI CONNECTOR FEMALE CODING KEY BRILLIANT BLUE V C CP 379 SCSI3 68 PIN C 1C 098 PCI9050 C 1C 099 93 546 DIP C 1C 035 8 PIN DIP SKT C 1C 056 7705 SOP C 1C 087 74 2 SOP C IC 100 74HCT273 SOP C IC 101 TAHCT244 SOP C 1C 090 93C56 SOP C 1C 081 UCN5832EP C MS 071
6. Runtime Engine is required to support the Pickering Test Panels application HARDWARE INSTALLATION CAUTION Electrostatic discharge can damage the components on the module To avoid such damage in handling the board touch the anti static bag to a metal part of the chassis before removing the board from the bag Ensure that there is adeguate ventilation in accordance with the PXI Specification The module should be installed in accordance with the following procedure 1 Ensure that the system is turned OFF but still connected to mains so that it remains grounded 2 Choose an appropriate slot in the rack 3 Remove the blanking plate for the chosen slot 4 Ensure that the injector ejector handle is in its downward position Align the module with the card guides on the top and bottom of the slot CAUTION Do not raise the injector ejector handle whilst inserting the module The module will not insert properly unless the hanale is in its downward position 5 Hold the handle whilst slowly sliding the module into the card guides until the handle catches on the injector ejector rail refer to Figure 3 1 6 Raise the injector ejector handle until the module firmly seats into the backplane The front panel of the module should be flush with the front panel of the chassis 7 Screw the front panel of the module to the front panel mounting rail 8 In a system employing MXI 3 to connect a desktop PC to a PXI chassis or to link multiple
7. alternative to the Test Panels the simple Terminal Monitor program PILMon again on the Programs gt gt Pickering gt gt PXI Utilities menu allows access to all functions of Pickering switch cards through a command line interface In PILMon enter HE for help on it s commands Please note that both the Test Panels and Terminal Monitor gain exclusive access to the cards and so only one of them can be operational at any time SHIELDED REED RELAY MODULES 40 120 125 Page 3 3 SECTION 3 INSTALLATION pickenng THIS PAGE INTENTIONALLY BLANK SHIELDED REED RELAY MODULES 40 120 125 pickering SECTION 4 PROGRAMMING SECTION 4 PROGRAMMING System 40 System 45 and System 50 cards are supported by comprehensive Windows software drivers and can also be programmed at register level There are two separate Windows drivers one accessing cards by Direct I O and the other through VISA Virtual Instrument Software Architecture Both are fully documented by ReadMe and HTML help files accessible through shortcuts on the Programs gt gt Pickering menu The following programming environments are supported for both drivers Microsoft Visual Basic Microsoft Visual C Borland C National Instruments LabWindows CVI National Instruments LabVIEW Support for all these environments is included in the standard installation Please refer to the PXI Switching Programming Manual for complete programming information
8. A and IVI drivers which are compatible with Windows 2000 NT XP operating systems the VISA driver is also compatible with the LabVIEW RT operating system These drivers may be used with a variety of programming environments and applications including National Instruments products LabVIEW LabWindows CVI Switch Executive MAX TestStand etc Microsoft Visual Studio products Visual Basic Visual C Agilent VEE Mathworks Matlab Other environments are also supported please contact Pickering with specific enquiries Power Requirements 3 3V 5V 12V 12V 0 360mA typ 280mA 0 0 Width and Dimensions Single slot PXI CompactPCI card DYI G Camna rFDCI famnlianra SHIELDED REED RELAY MODULES 40 120 125 24 x Shielded SPST Reed Relays 40 125 121 Mating Connectors amp Cabling Examples of connectors and cabling for the 40 110 series are 40 961 096 96 way SCSI style ribbon cable connector 40 970 096 1M Cableform 96 way SCSI Style Female to Female 1A 1m Length Connector Block Shielded 96 way SCSI Style Module Mounted 40 965 096 Please refer to the Pickering Interfaces Interconnection Solutions catalog for the full list of connector cabling options including drawings photos and specifications This is available in either print or as a download Alternatively our web site has dynamically linked connector cabling options including pricing for all Pickering PXI modules Latest Detail
9. Marne Le Vallee France Tel 33 1 60 53 55 50 Fax 33 1 60 53 55 99 email frsales pickeringtest com Pickering Interfaces AB Karl Nordstr msv g 31 432 53 Varberg Sweden Tel 46 340 69 06 69 Fax 46 340 69 06 68 E Mail ndsales pickeringtest com Pickering Interfaces s r o Smetanova 525 Trinec 739 61 Czech Republic Tel 42 0558 339 168 Fax 42 0558 339 168 E mail cesales pickeringtest com Page iii THIS PAGE INTENTIONALLY BLANK Page iv SHIELDED REED RELAY MODULES 40 120 125 CONTENTS Copyright Statement ii Technical Support and Warranty iii Contents this Page nase ee v Section 1 INTOUCHON rr asirese 1 1 Section 2 Technical Specification pp 2 1 Section 3 Installation nee 3 1 Section 4 PFOGIAMMING see sa 4 1 Section 5 Connector Pin OU 5 1 Section 6 Bes pm TT ee 6 1 Section 7 Functional Description aussen 7 1 Section 8 Parts E aeaiaioe rindai iaai 8 1 Section 9 Warnings and Cautions eere 9 1 SHIELDED REED RELAY MODULES 40 120 125 Page v THIS PAGE INTENTIONALLY BLANK Page vi SHIELDED REED RELAY MODULES 40 120 125 pickering SECTION 1 INTRODUCTION SECTION 1 INTRODUCTION GENERAL The 40 12 range of Reed Relay Modules form part
10. UTILITY The Pickering Diagnostic Utility accessible through the Programs gt gt Pickering gt gt PXI Utilities menu generates a diagnostic report of the system s PCI configuration highlighting any potential configuration problems Specific details of all installed Pickering switch cards are included All the installed Pickering switch cards should be listed in the Pilpxi information section if one or more cards is missing it may be possible to determine the reason by referring to the PCI configuration dump contained in the report but interpretation of this information is far from straightforward and the best course is to contact Pickering support support pickeringtest com if possible including a copy of the diagnostic report In the VISA information section if VISA is not installed its absence will be reported This does not affect operation using the Direct I O driver and is not a problem unless you wish to use VISA VISA is a component of National Instruments LabWindows CVI and LabVIEW or is available as a standalone environment If VISA is present and is of a sufficiently recent version the section Pipx40 information should present a listing similar to Pilpxi information Please note that the Diagnostic Utility cannot access cards if they are currently opened by some other application such as the Test Panels or Terminal Monitor SHIELDED REED RELAY MODULES 40 120 125 Page 6 1 SECTIONS TROUBLESHOOTING picke
11. chassis power up the system as follows a For a system comprising a PC and one chassis power up the chassis before powering up the PC b For a system comprising more than one chassis turn ON the last chassis in the system followed by the penultimate etc and finally turn ON the PC or chassis containing the system controller SHIELDED REED RELAY MODULES 40 120 125 Page 3 1 SECTION 3 INSTALLATION Dickering l PXI Chassis Injector Ejector Figure 3 1 Installing the module into a PXI Compact PCI Chassis TESTING OPERATION Start the Test Panels application from the Programs gt gt Pickering gt gt PXI Utilities menu If you are a LabVIEW user run Test Panels LabVIEW VI if not run Test Panels A selector panel will appear listing all installed Pickering PXI switch cards Click on the card you wish to control and a graphical control panel is presented allowing operation of the card Panels can be opened simultaneously for all the installed cards gt Card 1 40 560 021 0 1 00 File Help Pickering Interfaces System 40 m a totus I CadiD Bus Slt Ou Status Flag White 40 560 021 0 1 00 0 14 0 1 Operate Row Column Item State Single n matrix LF Sen Col 183 Col 151 Col 171 Col 133 Col 184 Figure 3 2 Typical Test Panel Display Page 3 2 SHIELDED REED RELAY MODULES 40 120 125 pickering SECTION 3 INSTALLATION As an
12. itch Type Ruthenium Reed Max Switch Voltage 150 DC 100V AC Max Power Max Switch Current Max Carry Current 20W 3W for SPDT 1A 0 25A for SPDT 1 2A 1A for SPDT On Path Resistance Path Resistance Differential Thermal Offset lt 250m0 gt 10 0 lt 10uV Safety CE Compliance All modules are fully CE compliant and meet applicable EU directives Low voltage safety EN61010 1 2001 EMC Immunity EN61000 6 1 2001 Emissions EN55011 1998 Connectors PXI bus via 32 bit P1 J1 backplane connector Signals via front panel 96 Way male SCSI connector for pin outs please refer to the operating manual Product Order Codes 16 x SPDT Ruthenium Reed Relays 40 110 021 Crosstalk 1000 balanced 80dB 1MHz 72dB 10MHz 32 x SPDT Ruthenium Reed Relays 40 110 121 62dB 25MHz 16 x SPST Ruthenium Reed Relays 40 115 021 Isolation 1000 balanced 75dB 1MHz 60dB 10MHz 32 x SPST Ruthenium Reed Relays 40 115 121 16 x DPST Ruthenium Reed Relays 40 115 022 Bandwidth 3dB 70MHz typical 24 x DPST Ruthenium Reed Relays 40 115 122 measured on 40 120 16 x Shielded SPDT Reed Relays 40 120 021 Operate Time lt 0 5ms 0 25ms typ 16 x Shielded SPST Reed Relays 40 125 021 Release Time lt 0 5ms 0 25ms typ Expected Life low power Expected Life high power Programming 1x10 operations gt 1x10 operations Pickering provide kernel VIS
13. nment and the health and safety of its employees customers and the public Pickering Interfaces endeavours to develop and manufacture products that can be produced distributed used and recycled or disposed of in a safe and environmentally friendly manner Observe the Electrical Hazard Warning detailed in Section 9 Observe the Electrostatic Sensitive Device Caution detailed in Section 9 Worldwide Technical Support and Product Information Siaha Wield CARL http www pickeringtest com Pickering Interfaces Headquarters Stephenson Road Clacton on Sea 15 4NL United Kingdom Tel 44 0 1255 687900 Fax 44 0 1255 475058 E Mail sales pickeringtest com Pickering Interfaces Inc 2900 Northwest Vine Street Grants Pass Oregon 97526 USA Tel 1 541 471 0700 Fax 1 541 471 8828 E Mail ussales pickeringtest com Pickering Interfaces Inc East Coast Regional Office 12 Alfred Street Suite 300 3 Woburn Massachusetts 01801 USA Tel 1 781 897 1710 Fax 1 781 897 1701 E mail useastsales pickeringtest com SHIELDED REED RELAY MODULES 40 120 125 Pickering Interfaces GmbH Buchenstrasse 15 D 77880 Sasbach Germany Tel 49 7841 66 49 10 Fax 49 7841 66 49 12 E Mail desales pickeringtest com Pickering Interfaces GmbH Office Munich Feringastrasse 6 D 85774 M nchen Germany Tel 49 8999 216 160 Fax 49 8999 216 200 E mail desales pickeringtest com 6 Rue De La Mare Blanche 77186 Noisiel
14. of the System 40 PXI Programmable Switching system The functionality of each module in the range is the same the part number being derived from tne number and type of relays e g single or two pole etc This module is used for construction of small switching networks for slaving Up to larger switches or for operating external devices The Relay Module is provided in the following configurations 16 x SPDT Shielded Reed Relay Part Number 40 120 021 16 x SPDT Shielded Reed Relay Part Number 40 125 021 24 x SPST Shielded Reed Relay Part Number 40 125 121 SHIELDED REED RELAY MODULES 40 120 125 Page 1 1 SECTION 1 INTRODUCTION piekering L THIS PAGE INTENTIONALLY BLANK Pageta SHIELDED REED RELAY MODULES 40 120 125 pickering SECTION 2 SPECIFICATION SECTION 2 SPECIFICATION OA Sg 14 Bi O A o Os A12 C 1 C12 a Sa Sc B 1 A o Sm C O u A21 OA Spe OE To c A gt OD e C24 Saz O Sca 2 A22 Ca gr As Een m O 5 As m ees M 241 OA Sei6 O So C244 OA A 32 Oo A 242 OA A 16 Cie OE oc a u Cs O C242 0 SaieO S cis S S c24 40 110 121 40 115 121 40 115 122 40 120 021 40 125 121 Switching Diagrams the 40 110 115 120 125 Reed Relay Module Switching Specification Sw
15. ring 1 THIS PAGE INTENTIONALLY BLANK Page 6 2 SHIELDED REED RELAY MODULES 40 120 125 a SECTION 7 FUNCTIONAL DESCRIPTION SECTION 7 FUNCTIONAL DESCRIPTION MECHANICAL DESCRIPTION The 40 12 range of Matrix Modules conform to the 30 height 128mm Eurocard standard Each module comprises the following Ejector Handle Front Panel mounted 96 way SCSI 2 Type connector 16 or 24 ShieldedRuthenium Reed Switches Two spare Shielded Reed Switches Compact backplane connector PCI Bridge U1 Control Logic The front panel is secured to the PCB by two M2 5 x 6mm pan head posi drive screws SHIELDED REED RELAY MODULES 40 120 125 Page 7 1 SECTION 7 FUNCTIONAL DESCRIPTION pickering FUNCTIONAL DESCRIPTION A functional block diagram is provided in Figure 7 1 The Reed Relay Module is powered by a 5V input via Compact PCI connector J1 The interface to the user test eguipment is via the front panel mounted 96 way SCSI type connector J2 The module comprises a PCB populated with shielded single pole or two pole relays depending on the module type The relays are energised via control signals from relay driver U8 The relay driver is addressed by PCI bridge U1 to output the required signal Module configuration is determined by hardwired links and data stored in EEPROM U7 PCI Bridge U1 is configured by EEPROM U2 96 WAY SCSI TYPE CONNECTOR J1 RELAY CONTACTS RELAY COILS COMPACT
16. s Please refer to our Web Site for Latest Product Details www pickeringtest com Operating Storage Conditions Operating Conditions Operating Temperature 0 C to 55 C Humidity Up to 95 non condensing Altitude 5000m Storage and Transport Conditions Page 2 1 SECTION 2 SPECIFCAMON piekering L THIS PAGE INTENTIONALLY BLANK Page 2 2 SHIELDED REED RELAY MODULES 40 120 125 pickering SECTION 3 INSTALLATION SECTION 3 INSTALLATION SOFTWARE INSTALLATION First install the appropriate Pickering PXI switch card drivers by running the installer program Setup exe either from the CD ROM supplied or by downloading the latest version from our website http www pickeringtest com the recommended method There are different versions of the Setup program to suit different Windows versions and software environments Setup is accompanied by a ReadMe file containing additional installation information A single installation covers all cards in the System 40 System 45 and System 50 ranges When installation completes the installed drivers file is offered for display It can also be displayed later using a shortcut on the Programs gt gt Pickering menu If you are not a LabVIEW user you should choose the full version and once that has been installed run the LabVIEW Runtime Engine installer via the shortcut on the Programs gt gt Pickering menu In the absence of LabVIEW the
17. s voltage by a double insulated transformer 3 Outer clothing worn must be unable to generate static charges 4 Printed Circuit Boards PCBs fitted with these devices must be stored and transported in anti static bags SHIELDED REED RELAY MODULES 40 120 125 Page 9 1 THIS PAGE INTENTIONALLY BLANK Page 9 2 SHIELDED REED RELAY MODULES 40 120 125
Download Pdf Manuals
Related Search
pickering pickering pickering funeral home pickerington ohio pickering ontario pickerington local schools pickering test pickerington pickering casino pickering weather pickering interfaces pickering emulsion pickering canada pickerington ohio zip code pickering casino resort pickering fellowship pickerington local school district pickerington heating and cooling pickering funeral home westborough pickering manor newtown pa pickerington zip code pickerington library pickerington north high school pickerington ohio county pickerington methodist hospital pickerington weather
Related Contents
630 EUROSIT Untitled - Indumil CATALOGUE Manual de Utilização SCI Linkkitchen 2.0 User Guide Mercedes-Benz 2010 R350 4MATIC Automobile User Manual GE 29484GE2 Telephone User Manual A&D SH-1000H/SJ-2000H/SJ-5000H/SJ-12KH User's Manual Samsung ES17 Uživatelská přiručka ESPECIFICAÇÃO TÉCNICA TRANSFORMADORES DE Copyright © All rights reserved.