Home
- NOVEXX Solutions
Contents
1. binding effect of this manual Contents The present manual refers exclusively to the LA BO applicator It is written for the purpose of en suring professional usage and calibration of the unit Prerequisites for the use and adjustment are the professional installation and configuration of the unit For any technical questions you may have that are not described in the user manual see e The service manual or e Request a service technician from one of our sales partners Our service technicians are available to assist you particularly with configuring the unit as well as in the case of malfunctions Technical status 10 2007 Copyright Avery Dennison holds all rights to this manual and its appendixes Reproduction reprinting or any other types of duplication even of portions of this manual may only be carried out with express written consent Third persons in particular competitors should not be given access to the infor mation in this manual Printed in Holland Manufacturer Novexx Solutions GmbH Ohmstrasse 3 85386 Eching Germany Phone 49 8165 925 0 Fax 49 8165 3143 www novexx com NOVEXxX Solutions reserves the right e To make modifications to construction parts components and software as well 85 to employ comparable components in place of the parts specified in keeping with technical advances To modify information in this document No commitment will be made to expand these modifications to incl
2. of the LA BO It is necessary to adjust the position of the blow pipe to obtain an aligned and straight label transport to the vacuum grid 10 Adjusting the air stream support 1 Use an Allen key of 2 5 mm to loosen the threaded pin of the blowpipe 2 Adjust the blowpipe so the maximum number of air holes are centered to the label width m f there are air holes outside the width of the label they should be closed off by the red rings m The air holes in the blow pipe should be directed to the vacuum grid Setting the dispensing position parameter When using the LA BO applicator the dispensing stop position should be set so that the label is just released when dispensed i e so that it no longer adheres to the carrier material If the label is not completely dispensed but is still partially attached to the carrier material the label will blown off side ways or upside down or will not be blown off by the LA BO Advancing the carrier material too far can cause the label be pulled back under the dispensing edge in case of strong adhesive or the following label can come in contact with the dispensed label Initializing the applicator There s no initialization of the applicator necessary If the ALX 92x or ALS 20x 256 is switched on the fan in the applicator is activated 08 2015 00 29 Mounting amp Setting Operating Manual LA BO NOVEX X lt 08 2015 00 SOLUTIONS Compressed air setti
3. time NOVEXX K SOLUTIONS Value 19 0 mm also depending on distance of label sensor to disp edge label must be entirely dis pensed Applic signals LA BO After start sig preferred setting for maximum output capacity 60 ms Tab 9 The parameter settings required for operating the LA BO applicator on an ALS 20x 256 Labeller firmware version 1 34 Firmware 1 34 Applicator interface m The SIGNAL INTERFACE gt Al BOARD SIGNAL menu appears if the optional applicator interface is installed and if SIGNAL INTERFACE gt Interface mode Applic signals Menu Parameter LABEL SETUP Lab stop offset SIGNAL INTERFACE Interface mode Applicator type SIGNAL INTERFACE gt Al BOARD SIGNAL Apply mode Blow on time Value 19 0 mm also depending on distance of label sensor to disp edge label must be entirely dis pensed Applic signals LA BO After start sig preferred setting for maximum output capacity 60 ms Tab 10 The parameter settings required for operating the LA BO applicator on an ALS 20x 256 Labeller firmware version 1 34 Firmware 2 52 Standard signal interface Menu Parameter LABEL SETUP Lab stop offset SIGNAL INTERFACE Interface mode Applicator type SIGNAL INTERFACE gt AP PLIC SIGNALS Apply mode Blow on time Value 19 0 mm also depending on distance of label sensor to disp edge label must be entirely dis pensed
4. 15 pins A9103 has to be ordered 2 LA BO for ALS 206 256 3 Filter regulator Required tools 5 Allen key 4mm Small size screwdriver 08 2015 00 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS Fitting the applicator 1 Remove the apply roller from the dispensing edge 1 and then remove the dispensing edge from the dispenser arm fixture by loosing the M8 bolt 2 Remove the black bracket from the dispenser rods by releasing the 2 M5 bolts 3 at the bottom side 2 Slide the aluminium bracket of the LA BO over the 2 dispenser arm rods 1 and tighten the screws 2 3 Remount the black bracket on the dispenser arm rods 1 and adjust the height of the LA BO so that there s a distance of approximately 39 mm to the black bracket for the dispensing edge Remount the dispensing edge of the ALS 20x 256 2 08 2015 00 19 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS 4 Plug the cable of the LA BO into the high density D sub connector in the Al board at the back side of the ALS 20x 256 or into the D Sub 15 connector when using Internal Applicator Interface adapter connector A9103 necessary Install the included filter regulator somewhere close by the LA BO e g on the support stand of the ALS 20x 256 Connect the LA BO to the filter reg ulator Connect the compressed air to the filter regulator Max 5 Bar 08 2015 00 20 Mount
5. 2X firmware V3 30 or later e Required version of the ALS 20X 256 firmware V1 17 or later Al The printer dispenser must be equipped with an Application Interface Al board version V1 11 or later Start signal The start signal must be connected to the Product sensor input of the Al interface When the Inter nal Applicator interface on the ALS is used the startsignal must be connected to the M12 connector Start m See service manual ALX 92x ALS 20X 256 256 Applicator Interface topic section chapter In terface signals Product Sensor For using the M12 connector on ALS see Service manual ALS 20x 256 Connecting the sensors Properties LA BO Label Applicator Blow On The applicator is driven by compressed air The label is held to the aluminium grid on the bottom side of the applicator by an inwards airflow created by a fan on the side of the applicator Mode of Operation The fan in the LA BO is continuously powered creating a strong inwards airflow through the alu minium vacuum grid at the bottom side While a label is dispensed the small blow pipe is activated creating a small focused air stream to force the label against the aluminium grid When the label is fully dispensed it is held onto the aluminium grid by the inwards airflow and is then stand by to blow off the label When the application cycle is triggered by the product sensor a high volume air pres sure is applied through th
6. Applic signals LA BO After start sig preferred setting for maximum output capacity 60 ms Tab 11 The parameter settings required for operating the LA BO applicator on an ALS 20x 256 Labeller firmware version 2 52 08 2015 00 23 Mounting amp Setting Operating Manual LA BO 08 2015 00 Firmware 2 52 Applicator interface NOVEXX K SOLUTIONS m The SIGNAL INTERFACE gt Al BOARD SIGNAL menu appears if the optional applicator interface is installed and if SIGNAL INTERFACE gt Interface mode Applic signals Menu Parameter LABEL SETUP Lab stop offset SIGNAL INTERFACE Interface mode Applicator type SIGNAL INTERFACE gt Al BOARD SIGNAL Apply mode Blow on time Value 19 0 mm also depending on distance of label sen sor to disp edge label must be entirely dispensed Applic signals LA BO After start sig preferred setting for maximum output capacity 60 ms Tab 12 The parameter settings required for operating the LA BO applicator on an ALS 20x 256 Labeller firmware version 2 52 24 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS ADJUSTING THE LABELLING APPLICATION HEIGHT 08 2015 00 In general to obtain a good apply accuracy of the label on the product it is recommended to adjust the LA BO as close as possible to the product surface Obviously a safe distance has to be respect ed so the conveyed products can n
7. IONS MOUNTING ON AN ALX 92X Requirements Required components Component Part number A8679 LH Basic Module LA BO 8680 RH Bolt Set 3x screw ISO7380 M5x20 included Filter regulator included Tab 3 These parts are required to mount the LA BO on an ALX 92x 1 LA BO for ALX 92x Required tools e Allen key 3mm e Small size screwdriver m For ALX 92x supplied before May 2007 3 mounting holes have to be drilled in the ALX 92x ground plate Please refer to User manual page 36 for detailed instructions 08 2015 00 14 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS Fitting the applicator 1 Pull out the black top left knob 1 and turn the LA BO housing in the upper position 2 3 Plug the cable of the LA BO into the D sub connector of the ALX 92x on the top side of the print er unit 08 2015 00 15 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS 4 Connect the applicator to the compressed air Adjusting the dispensing edge to the vacuum grid After fitting the applicator the position of the dispensing edge in relation to the vacuum grid of the applicator must be verified and adjusted if necessary When viewed from the side the bottom sur face of the vacuum grid must be slightly below and in front of the dispensing edge fig 11 Position of dispensing edge to vacuum grid As a guideline the center of the dispensin
8. NOVEXX SOLUTIONS OPERATING MANUAL LA BO Applicator Release 1 8 2015 Operating Manual LA BO SOLUTIONS Content General Notes amp Safety Instructions 5 General notes 5 Validity and binding effect of this manual 5 Illustrations and descriptions 6 Safety instructions 7 Information and qualifications 7 Operational safety of the unit 8 Technical Data 10 Application Notes 10 Intended Purpose 10 System Requirements 10 Properties 11 Mode of Operation 11 Specifications 12 Mounting amp Setting 13 Safety Instructions 13 Mounting on an ALX 92x 14 Requirements 14 Fitting the applicator 15 Adjusting the dispensing edge to the vacuum grid 16 Parameter settings on the ALX 92x 17 Mounting on an ALS 20x 256 18 Requirements 18 Fitting the applicator 19 Adjusting the dispensing edge to the vacuum grid 21 Parameter settings on the ALS 20x 256 22 Adjusting the labelling application height 25 Adjusting the LA BO to the used label material 26 Adjusting the sliding bars in the vacuum grid 26 Adjusting the air nozzles in the vacuum grid 28 Adjusting the air stream support 29 Setting the dispensing position parameter 29 Initializing the applicator 29 Compressed air settings 30 08 2015 3 Content Operating Manual LA BO NOVEX X lt SOLUTIONS 08 2015 4 ii Operating Manual LA BO NOVEX X lt SOLUTIONS General Notes amp Safety Instructions GENERAL NOTES Validity and
9. X X lt SOLUTIONS Mounting amp Setting SAFETY INSTRUCTIONS WARNING The applicator uses a large air flow to blow off the label which is held at the bottom side of the applicator Don t look straight in to the vacuum grid of the running applicator to avoid that dust or label residues are blown into your eyes gt When setting the applicator make sure that the applicator cannot be triggered unintentionally e When mounting dismounting or servicing the LA BO make sure the labelling head ALX 92x or ALS 20x 256 and the air pressure are switched off The operating air pressure must be at least 5 bars and no more than 6 bars The applicator may only be assembled and commissioned by qualified personnel The applicator housing may only be opened by authorized technicians Repairs to the applicator may only be performed by authorized technicians who are aware of the risks involved Check the applicator regularly for defective parts Replace defective parts immediately and only by original spare parts provided by the manufacturer By doing so you avoid hazards caused by spare parts of low quality The applicator construction must not be modified e g by installing a larger pneumatic valve Unauthorized modifications changes or improper usage exclude all liability on the part of the manufacturer for damage resulting there of 08 2015 00 13 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUT
10. d Therefore the air nozzles of the LA BO can be fine adjusted in the X width and Y length direction in reference to the label area To adjust the air nozzles in X direction width of label 8 Adjusting the air nozzles across feeding direction gt Turn the black lower right knob 8A clockwise or counter clockwise until the sliding bars noz zles are centered over the width of the label m This setting becomes more critical for smaller label sizes If the non closed nozzles are not cen tered over the width of the label the label will move sideways during the blow on action To adjust the air nozzles in Y direction length of label A 75 100 mm A lt 75mm 9 Adjusting the air nozzles in feeding direction 1 Loosen the 2 small black knobs 9A and slide them towards the dispensing edge for label for mats with a length of less than 75 mm In case the label is longer than 75 mm slide the 2 small black knobs away from the dispensing edge 2 Retighten the 2 small black knobs m For small label formats less than 40 mm width it is recommended to check if the open noz zles are centered over the width of the label 08 2015 00 28 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS Adjusting the air stream support The small brass blow pipe 10 creates an air stream during the dispensing of the label to support the label towards the vacuum grid
11. e air nozzles built in above the aluminium grid The nozzles which are not covered by the black sliding bars will now blow off the label towards the product at a high ve locity After that the next label can be dispensed on the grid 08 2015 00 11 Technical Data Operating Manual LA BO SPECIFICATIONS Material type Label size Application distance Application capacity Product speed Application angle Application accuracy Control Compressed air Air consumption Dimensions Weight Environmental conditions Protection class Power consumption Supply voltage Noise level Tab 2 Technical specifications of the LA BO a Depending on label size SOLUTIONS Self adhesive labels of paper PE or PP Min 30 x 30 mm Max 100 x 100 mm Min 20 mm Max 100 mm 3 Up to 160 labels min From 0 up to 120 m min 5 90 10 Typically 1mm 2 Applicator Interface 5 6 bar Appr 1 Itr apply cycle ALX 92x 300 x 345 x 153 mm ALS 20x 256 357 x 188 x 153 mm 3 5 kg Enclosed rooms Working temperature 5 to 40 C Storage temperature 0 to 60 C Relative humidity 30 to 80 non condensing IP 21 15 VA 24 V DC from ALX or ALS 82 dB A during blow cycle b Depending on label size and time necessary for trailing edge of label to be released from backing paper c Depending on labelsize blow distance productsurface and accuracy 12 Technical Data Operating Manual LA BO NOVE
12. g edge should be positioned approximately 1 mm above the vacuum grid surface To adjust Loosen the fixing screws of the angular adjustment of the dispensing edge rotate the dispensing edge in the desired position and retighten the screws 08 2015 00 16 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS Parameter settings on the ALX 92x PRINT PARAMETERS Dispense position O mm label must be entirely dispensed Head disp dist 24 5mm SYSTEM PARAMETERS Save Mode recommended for difficult release of trai Application mode ling edge of label material Applicator type ASA After start sig APPLICATOR PARA Application mode preferred setting for maximum output capacity Blow on time 60 ms Tab 4 The parameter settings required for operating the LA BO applicator on an ALX 92x 08 2015 00 17 Mounting amp Setting Operating Manual LA BO SOLUTIONS MOUNTING ON AN ALS 20X 256 Requirements Required components Component Part number A8677 LH Basic Module LA BO for ALS 204 A8678 RH A9824 LH Basic Module LA BO for ALS 206 256 A9825 RH included Filter regulator Tab 5 These parts are required to mount the LA BO on an ALS 20x 256 u When mounting LA BO to ALS 206 256 an additional spacer block A9090 for the L shape fixture has to be ordered it When using the Internal Applicator Interface on ALS 20x 256 an adapter connector 44 pins to
13. he label is not dispensed straight on the grid or still sticks with the trailing edge on the dispenser please check the height adjustment of the dispenser in relation to the vacuum grid 3 Carefully adjust the bars to the label size by moving the knobs just against the label edge with out touching the edge of the label Bars outside the width of the label should be fully moved inwards the vacuum grid so all the air nozzles above this bar are closed 4 Proceed some dispensing tests and check if the knobs on the bars are not touching or holding the edge of the dispensed label 08 2015 00 26 Mounting amp Setting Operating Manual 4 SOLUTIONS 6 Adjusting the bars in the vacuum grid so air nozzles outside the label surface are closed off m In most applications with a blow on applicator it will be difficult to visually verify the position of the sliding bars from the bottom side of the vacuum grid Therefore the bars can also be adjusted by matching the section of the bars outside the vacuum grid to the label surface as shown on 7 7 Adjusting the bars in the vacuum grid by matching the outside section of the sliding bars with the label surface 08 2015 00 27 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS Adjusting the air nozzles in the vacuum grid To achieve optimal labelling apply accuracy it is important to adjust the blow off air flow in the center of the label under the vacuum gri
14. hearing protection Keep the product information at hand With respect to this manual 5 It should be kept at the location where the unit is installed and be available to the operator 5 It should always be legible 5 If the unit is sold the manual should be made available to the new owner e The safety and warning notes affixed to the unit itself must be kept clean and legible Missing or damaged signs must be replaced Ensure the required qualifications are met e Ensure that only trained and authorized personnel operate configure and service the unit e Only allow qualified and well trained expert personnel or service technicians to perform config urations e The responsibilities with regard to operation configuration and maintenance should be clearly defined and consistently maintained e In addition personnel should also be instructed on a regular basis in matters of occupational safety and environmental protection Qualification for operation The instruction of personnel using the unit must ensure that e The operating personnel can use the unit on their own and safely e The operating personnel can remedy small operational disruptions on their own At least two people must be instructed in the unit s usage e Enough label material must be provided for testing and instructional purposes 08 2015 00 7 General Notes amp Safety Instructions Operating Manual LA BO NOVEX X lt SOLUTIONS Operational safety of the u
15. ing amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS Adjusting the dispensing edge to the vacuum grid After fitting the applicator the position of the vacuum grid of the applicator in relation to the dispens ing edge must be verified and adjusted if necessary When viewed from the side the bottom sur face of the vacuum grid must be slightly below and in front of the dispensing edge fig 11 Position of dispensing edge to vacuum grid As a guideline the vacuum grid surface should be positioned approximately 1 mm below the center of the dispensing edge To adjust Loosen the fixing screws of the applicator s bracket adjust the height of the LA BO to the dispensing edge and retighten the screws 08 2015 00 21 Mounting amp Setting Operating Manual LA BO NOVEXX K SOLUTIONS Parameter settings on the ALS 20x 256 Firmware 1 10 Menu Parameter MACHINE SETUP Act Apl Interf LABEL SETUP Lab stop offset Applicator type APPLICATOR PARA Apply mode Blow on time Value Int appl Interf Activates the internal applicator in terface Ext appl Interf Appears only if the optional appli cator interface is installed 19 0 mm also depending on distance of label sensor to disp edge label must be entirely dispensed ASA After start sig preferred setting for maximum output capacity 60ms Tab 6 The parameter settings required for operating the LA BO applicato
16. ngs CAUTION The applied compressed air must match the following conditions to assure proper operation of the applicator gt The maximum air pressure must not exceed 6 bar A higher pressure can damage the device gt The air pressure must be kept constant to ensure the correct operation of the applicator The Blow on applicator should be operated with an air pressure of 5 6 bars Air pressure valve There is only one large 5 3 air pressure valve located at the back side of the applicator base plate 11 The valve has 2 electrical coils and therefore 3 positions If both coils are not activated the LA BO is in a stand by status and no air pressure is used If the upper coil is activated the valve switches the air flow to blow off the label from the vacuum grid If the lower coil is activated the valve switches the airflow to the blow pipe which functions as a support air stream to guide the label against the vacuum grid during dispensing of the label 11 The pressure valve is located on the back side of the base plate 30 Mounting amp Setting Ohmevate 3 GmbH 85386 Eching SOLUTIONS Germany 49 8165 925 0 http Awww novexx com
17. nit Proper usage Applicators of type LA BO are additional units for Avery Dennison print and apply or labelling heads The applicators take self adhesive labels from the dispenser mechanism and stick these onto moving or non moving products The company operating the unit must install it with suitable equipment to protect operating personnel from danger for example the danger of hands or fingers being crushed by reaching in between the product and the dispensing edge WARNING Improper usage of the unit can cause accidents property damage and production downtime Only use the unit in accordance with the instructions specified in this manual gt Only configure the unit in accordance with this manual and with the required care gt Only use original accessories Do not make any modifications or alterations to the unit gt Repairs to the device may only be performed by authorised specialists who are aware of the risks involved Protection against injuries by electrical current Applicators of type LA BO operate using low voltage 24 V DC supplied by Avery Dennison print and apply or labelling heads WARNING Never connect the LA BO unit directly to mains voltage Only operate the unit once the housing has been reassembled properly Before cleaning switch off the Avery Dennison print and apply or labelling head and remove the power cable from the socket WARNING The unit is not pro
18. ot come in contact with the parts of the LA BO especially the blow pipe for air stream support Variations in product height also have to be considered when adjusting the height of the LA BO The labelling distance of the LA BO to the product surface may vary between 20 mm and maximum 100 mm 4 Labelling distance between LA BO and product 25 Mounting amp Setting Operating Manual LA BO NOVEX X lt SOLUTIONS ADJUSTING THE LA BO TO THE USED LABEL MATERIAL The following adjustments have to be made every time the label format is changed on the ALX 92x or ALS 20x 256 Adjusting the sliding bars in the vacuum grid Because the blow on applicator needs to create a strong air flow evenly spread over the label sur face it is important to adjust the sliding bars of the vacuum grid This is done by sliding them in or out until the opening in the vacuum grid matches the label size of a dispensed label Once this set ting is done the sliding bars will close off the air nozzles which are positioned outside the label area 1 Adjust the bars of the vacuum grid enough outside so a label can be dispensed freely on the vacuum grid without touching any of the knobs on the bars 5A 5 The sliding bars in the vacuum grid must be adjusted to close off air nozzles outside the label surface 2 Dispense a single label on the vacuum grid of the applicator The label should not touch any of the knobs on the adjusting bars If t
19. ove the applicator e Horizontal also referred to as side labelling the product is located next to the applicator System Requirements Machine type The LA BO can be operated on the following machines Device Part number LA BO Controller Notes ALX 924 925 926 LH A8679 Al ajbjc ALX 924 925 926 RH A8680 ALS 204 206 256 LH A8677 dab Al or internal rye ALS 204 206 256 RH A8678 Tab 1 Print and Apply and labelling machines to which the LA BO can be applied LH lefthand RH righthand Al Applicator Interface a Use of the Al is mandatory for ALX b The Applicator Interface Al is not contained in the scope of delivery and has to be ordered separately with the ALX or ALS unit A5032 Al factory installed A5207 Al Upgrade kit ALX 924 925 926 has to be equiped with standard dispensing edge d Use of the Al is optional for the ALS The Internal applicator interface of the ALS can be used also but limits the use of PLC signals e ALS 20x 256 256 has to be equiped with L shape fixed dispensing edge By ordering the specified part number you will receive a LA BO applicator with installation material and connection cables suitable for installation on the device type listed at the beginning of the line The Applicator Interface Al board is not part of the delivery and has to be ordered separately 10 Technical Data Operating Manual LA BO NOVEX X lt SOLUTIONS Firmware e Required version of the ALX 9
20. r on an ALS 20x 256 Labeller firmware version 1 10 Firmware 1 33 Standard signal interface Menu Parameter LABEL SETUP Lab stop offset SIGNAL INTERFACE _ Interface mode Applicator type SIGNAL INTERFACE gt APPLICATOR INT PPY mode Blow on time Value 19 0 mm also depending on distance of label sensor to disp edge label must be entirely dispensed Applicator int ASA After start sig preferred setting for maximum output capacity 60ms 80 7 The parameter settings required for operating the LA BO applicator on an ALS 20x 256 Labeller firmware version 1 33 Firmware 1 33 Applicator interface m The APPLICATOR PARA menu appears if the optional applicator interface is installed Menu Parameter LABEL SETUP Lab stop offset Applicator type APPLICATOR PARA Apply mode Blow on time Value 19 0 mm also depending on distance of label sensor to disp edge label must be entirely dispensed ASA After start sig preferred setting for maximum output capacity 60ms 40 8 The parameter settings required for operating the LA BO applicator on an ALS 20x 256 Labeller firmware version 1 33 08 2015 00 22 Mounting amp Setting Operating Manual LA BO Firmware 1 34 Standard signal interface Menu Parameter LABEL SETUP Lab stop offset SIGNAL INTERFACE Interface mode Applicator type SIGNAL INTERFACE gt APPLIC SIGNALS Apply mode Blow on
21. tected against splashing water gt Keep the unit dry gt If liquids have penetrated the LA BO unit switch the Avery Dennison print and apply or la belling head off and disconnect or unplug it s power cable immediately Inform a service techni cian Protection against injuries by mechanical action WARNING Risk of injury due to moving and rapidly rotating parts Long hair loose jewellery long sleeves and so on are not permissible when using the unit gt Sufficient protective clothing must be worn gt Keep moving parts free from obstructions even when the unit is not switched on if there is a chance the machine might be turned on gt Switch off the machine before making any mechanical settings Do not wear ties loose clothing jewellery wrist watches or similar items on your person when near the operating unit 08 2015 00 8 General Notes amp Safety Instructions Operating Manual LA BO NOVEX X lt SOLUTIONS WARNING There is a low risk that you may get your hands crushed between the vacuum grid of the LA BO and the conveyed products Never reach between the product and the LA BO edge while the unit is in operation or ready for operation Protection against injuries by chemicals CAUTION Operating materials such as cleaning agents or the solvents in glues can be damaging to health gt Always follow the instructions use and safety regula
22. tions specified by the manu facturer 08 2015 00 9 General Notes amp Safety Instructions Operating Manual LA BO NOVEX X lt SOLUTIONS Technical Data APPLICATION NOTES 08 2015 00 Intended Purpose Applicators of type LA BO are additional units for print and apply or labelling heads that are listed in the section Machine type on page 10 They take self adhesive labels from the dispenser mech anism and stick these onto moving or non moving products The LA BO is mounted to the print and apply ALX 92x or labelling head ALS 20x 256 by means of an included base plate The applicator is controlled by the optional Applicator Interface Al board mandatory for ALX and optional for ALS or by the Internal Applicator Interface ALS only The electrical connection to the LA BO is done via a plug connector The drive is provided by com pressed air Remark The optional Applicator Interface Al board is not included with the LA BO and has to be ordered separately with the print and apply or labelling head The application process is triggered by means of a product sensor which is also connected to the Al board Installation position Permissible installation positions for the LA BO are e Vertical if application takes place from top to bottom also referred to as top labelling the product is located below the applicator or from bottom to top also referred to as bottom label ling the product is located ab
23. ude any units delivered earlier 08 2015 00 5 General Notes amp Safety Instructions Operating Manual LA BO NOVEX X lt SOLUTIONS Illustrations and descriptions Dangers and risk notes Important directions that you must absolutely observe are particularly emphasized WARNING A warning refers to risks that can lead to serious injury or death The warning contains safety measures to protect the relevant persons Always follow the instructions Figures Texts are accompanied by figures where necessary Generally the LA BO unit shown is a right handed version The left handed version is only shown where it is necessary to differentiate between the two 08 2015 00 6 General Notes amp Safety Instructions Operating Manual LA BO NOVEX X lt SOLUTIONS SAFETY INSTRUCTIONS Information and qualifications Follow the instructions WARNING Safe and efficient operation of the LA BO unit can only be guaranteed if you observe all neces sary information Product liability and warranty claims can only be asserted if the unit was operated in accordance with the directions in the manual gt Before operating the unit read the operating instructions and all other notes carefully Observe the additional safety and warning notes on the LA BO unit gt Only permit competent people to operate and configure this unit gt When working with the LA BO for a longer period it is advisable to use
Download Pdf Manuals
Related Search
Related Contents
User Manual 2e Forum des élus et de l`emploi territorial - forum I Istruzioni per l`uso Thor Gas Oven Installation and Operation Instructions Europa B evo Europa B evo 24 - Tecno-Gaz PREVIEW the Rice Lake 720i Indicator installation and service manual HBAC-20 guitar combo user manual Schließnaht-Anlage Serie 1280/4 Betriebsanleitung User Manual Copyright © All rights reserved.