1. Manual del usuario User s manual Electroac stica General Ib rica S A Index 1201 Control console 1301 Audio processor 28 29 30 1202 Control console 31 Basic operation Access restrictions 32 34 34 Advanced functions Operation of the module for paging over the telephone 35 38 39 Operation of the pre recorded message player Central Rack Modules 40 42 43 1204 2 Channel 5 W control unit 44 1203 Intercom unit 44 45 1105 Pre amplified XLR microphone base 1107 Volume regulator for mic base 1105 45 1106 Auxiliary input 46 1501 Wall base for connection of control consoles and music sources 1205 4 Channel 1 W control unit 46 47 1206 Digital control keyboard 47 1207 4 Channel 2 W control unit 48 Adapting musical sources to the audio processors 49 Guarantee 51 Overview Congratulations you have beenprovided witha MILLENNIUM sound intercommunication and Public Address system that will offer you multiple services The MILLENNIUM system begins in the processor module that is in charge of receiving and emitting the audio and control signals for the installation The control consoles manage and control all the features of the installation and messages and warnings can be emitted from them In different parts of the installation you can have local contro
2. a SETUP As long as we keep the button pressed what is said to the microphone will be broadcast in all the selected zones It is also possible to select several groups or zones or even a combination of groups and zones taking into account that if we enter a group to select some of its zones the selection of that group as a whole unit will automatically be cancelled If the paging line is busy because another call is being broadcast or a pre recorded message is being played or saved from another console 1202 instead of the last two screens the following message will appear Control console 1202 Access restrictions 1202 o Enabling and disabling the general access password 2 Entering the general access password If three groups for instance have been previously created e e e e o e e e e e e e a SETUP O A SETUP Provided that there is NEITHER a pre recorded message player 1103 NOR a module for sending messages over the telephone 1104 in the system e e g o a n SETUP Y MORE e g o n n SETUP O PASSWORD e e e e a n SETUP P NO disables the general access password P 1 P 243 avitum on the led lamp next to YES If then we press ves then the code 1234 has been enabled as general access password The 4 bottom keys An 3A A SETUP and AY act here as numeric keys If the general access password is acti ve whenever we want to access
3. as you keep on pressing the button Push button LOCK By pressing this push button the zone 2 will stay permanently selected you can talk to zone 2 even if the push button 2 is released A red lamp informs you that the communication with zone 2 is permanently open If this button is pressed again the lock function is disabled Volume regulator zone 1 By turning this screw clockwise we will raise the volume level of the message broadcast in zone 1 Volume regulator zone 2 By turning this screw clockwise we will raise the volume level of the message broadcast in zone 2 1203 MI E L E N NL UEM BLA Pre amplified XLR microphone base 1105 Professional XLR microphone socket Microphone type selector This switch enables the user to select which type of microphone will be connected to the XLR socket dynamic electret without power supply or electret with phantom power supply Pilot lamp ON Itkeeps on lighted while the device is working correctly no matter if there is a microphone connected or not Volume regulator for mic base 1105 1107 Push button ON OFF One press turns on and the next press turns off the microphone base 1105 On lamp Indicates that the microphone base is avaible to be used Volume regulator To turn up Nor down V the volume level of the microphone signal Pilot lamp for volume regulation It blinks when the volume level of the microphone reaches i
4. instance have been previously created A SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 gt TIME e a SETUP O gt or modifies the hour d or 4 modifies the minute PE adjusts the time of the system Central Rack Modules 1315 Power Supply Unit Once connected to 230 V it supplies 15 Vdc for the other devices in the central rack and for the general line as well Central Processing Unit 1316 It is the main device that controls the different elements of the system It communicates with the system devices monitoring the control parameters It allows the adjustment of such parameters through the control console 1202 Pre Amplified Audio Input 1101 1 It allows the insertion into the system of low level audio signals like the ones supplied by standard audio sources like CD Players Cassette Players etc Each 1101 1 module provides two audio programs what means that no more than two modules of this type can be present in one system FM Radio tuner 1102 1 Radio tuner that operates in the FM band 88 108 MHz It can be operated from the control console 1202 It is equipped with a low level audio input that can be switched with the radio tuner The 1102 1 module provides only one audio program what means that up to four mod
5. n SETUP O gt MESSAGE amp E n SETUP O d usa 3 e e g o n n o MORE e g e n SETUP O EXT MC And then the sign gt appears next to EXT MC e Starts recording the message from the gooseneck microphone in the control console or from an external microphone connected to the RCA socket in the pre recorded message player depending on where the symbol gt is As long as we keep the key pressed a countdown starting from 15 will let us know the time remaining to finish up the record The message record willfinish when the countdown reaches 0 or when we release the button whatever comes first If the paging line is busy because another message is being broadcast or a pre recorded message is being played or saved from another console 1202 instead of starting the record the following message will appear e o e SETUP 5 2 O Erasing a message 1202 If the general access password is active the system will require us to introduce it every time we try to operate this module see point 2 of access restrictions O Time setting If three groups for instance have been previously created A SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 n SETUP P YES erases message number 1 If three groups for
6. telephone password is NOT active and there is 1104 in the system NEITHER a pre recorded message player 1103 NOR a module for e e sending messages over the telephone o o 1104 in the system o e o e gt gt more se e e z more e e o e Fi set F Em lt SOFTWARE VERSION WS m FA m EA hy JE IE E 18 sis VENDA Control console 1202 Operation of the module for sending messages over the telephone 1202 If the general access password is active the system will require us to introduce it every time we try to operate this module see point 2 of o Changing the length of the time while a message over the telephone can be broadcast If three groups for instance have been previously created e e e e e e LJ e e e e e a m SETUP O A SETUP Provided that the general access password is NOT active and there is NOT a pre recorded message player 1103 in the system but THERE IS a module for sending messages over the telephone 1104 e g p SETUP lt T PHONE n E or modifies the maximum time length while a message can be broadcast access restrictions O Assigning a telephone number to a zone o Assigning a telephone number to a group If three groups for instance have been previously created A SETUP Provided that the general access password is NOT active and there is NOT a pre recorded message player 1103 in the sys
7. to the advanced functions of the system the module for sending messages over the telephone or the pre recorded message player a password will be required by the following screen e e e e e e e e e e e e a SETUP O The 4 bottom keys AJ A A SETUP ad AW act here as numeric keys If we make a mistake when entering the password it is possible to start again by pressing amp ERASE For each entered digit a symbol will be substituted by a symbol M AAA NASAL UEM jl p E Control console 1202 Advanced functions 1202 Q Giving a number to each zone This is the first thing that has to be done in order to configure a system and it does not have to be done again if the system configuration is not modified Provided that no groups have been created yet e e e m SETUP O A SETUP If the general access password is NOT active and there is NEITHER a pre recorded message player 1103 NOR a module for sending messages over the telephone 1104 in the system e o g e n SETUP O lt d ZONES e e e e a mo SETUP lt ZONE SET cancels all the numbers that have been given to the zones until pressed 4 P HERE gives to the control console 1202 the zone number I the console needs a zone number only if it must be ready to receive messages ZONE SET When pressed the system is ready to assign number 1 to a zone and all the zone set led lamps of
8. O If one group has already been created n SETUP O D GR 01 And then the sign lt appears next to GRO1 If the general access password is NOT active H see o gt ZONES Provided that there are 3 numbered zones in the system and zone number 2 belongs to group number 1 setup 5 D gt ZON 001 gt gt ZON 002 Now zone number 1 belongs to group number 1 and zone number 2 does not Ez 5 groups in the screen If three groups for instance have been previously created E gt GR 01 And then the sign lt appears next toGR01 If the general access password is NOT active RN lt CHANGE GR 03 serv EK Now it is recommended to initialise the system again like in point number 13 so that the system checks again the relationships between groups and zones If three groups for instance have been previously created e e e e a SETUP O GR 03 And then the sign gt appears next to GRO3 If the general access password is NOT active c e o n SETUP lt ERASE e e e co gt YES o o o ce n m SETUP M I L L E N N 1 U M Edi 1 202 If the general access password is active the system will require us to introduce it every time we 37 Control console 1202 Advanced functions try to operate one of the advanced functions see point 2 of access restriction
9. On and Off If three groups for instance have been previously created M KS P gt GENERAL Andthe sign lt appearsnext 10 GENERAL gt ZONE If three zones for instance have been previously named RU P gt ZON001 And the sign lt appears next to ZONOO1 J If the zone was previously off m Es m KS m ane Changing the audio channel in a zone If three groups for instance have been previously created Es P gt GENERAL And the sign lt appears next to GENERAL ZONE sive gt ZON 001 And the sign lt appears next to ZON 001 A fl If the zone was previously on see P gt CHAN 1 Provided that at least 2 channels are available at the system am E O Altering the volume level of a zone If three groups for instance have been previously created D GENERAL And the sign lt appears next to GENERAL gt ZONE If three zones for instance have been previously named gt ZON 001 And the sign lt appears next to ZON 001 A fd o 4 alters the volume level of the previously selected zone MAIRENA ME UEV pcc Control console 1202 Basic operation 1202 o Turning a Group of zones On and Off in a specific channel e e e e n m SETUP O DP GR 01 And then the sign lt appears next to GRO A Jl Provided that there are for instan
10. ars next to ZON 001 A n If the general access password is NOT active o a n a SETUP O SETUP P NAME E gt gt gt the cursor is placed in letter O lt O is replaced by P P g e e a SETUP If the general access password is active the system will require us to introduce it every time we try to operate one of the advanced functions see point 2 of access restrictions o Creating a group and giving it a number If NO groups have been created yet n SETUP O D GENERAL And then the sign lt appears next to GENERAL A 1 If the general access password is NOT n m sme o n SETUP O n sme O Egi 35 E dV ICE es INTIS EA EXE d 1 202 If the general access password is active the system will require us to introduce it every time we try to operate one of the advanced functions see point 2 of access restrictions Control console 1202 Advanced functions 4 Labelling groups with names o Assigning a zone to a group Q Changing the order of appearance of Q Erasing a group If one group has already been created n SETUP O P GR 01 And then the sign lt appears next to GRO1 amp If the general access password is NOT active e o g e n n SETUP O P NAME o e o n n SETUP 4 gt gt gt the cursor is placed in letter R 4 R is replaced by Q e e SETUP
11. ce 4 channels available at the system e e o o n m SETUP O CHAN 1 B CHAN 2 CHAN 3 CHAN 4 turn the group ON at the selected channel or amp TURN OFF turns the audio OFF in the selected group O Changing an audio channel from external AUX music source to internal radio Tuning of a channel with internal radio If three groups for instance have been previously created o e e o o o e e e n SETUP a Provided that there are for instance 4 channels available at the system P CHAN 1 Provided that there is an internal RA DIO tuner available for CHANNEL 1 but the channel is in AUXILIAR mode e e o n n sme o5 DP RADIO And then the sign lt appears next to RADIO AS Provided that there are for instance 4 channels available at the system P CHAN 1 Provided that there is an internal ra dio tuner available for CHANNEL 1 and the channel is in RADIO mode O o g e n SETUP O ds or 4 short press tunes the radio 0 1 MHz up or down lt d or 4 long press searches for the next available radio station in a higher or in a lower frequency Making a call to zones which are not in private mode If three groups for instance have been previously created e e o e n SETUP O DP GR 01 And then the sign lt appears next to GR O1 O e o e o e o e o e e g o a n SETUP o e e o o
12. cludes one With the key amp we move up the dial and with the key O we move it down Reserved push button Push button to be used in more advanced versions Push button for turning ON OFF a zone Once the zone s are selected this push button allows you to turn ON or OFF the ambient music function The symbol OF or J 1 will appear depending on whether it is turned OFF or ON Bell menu button Once the zone s are selected pressing this push button gives access to another menu that allows you to turn ON or OFF the option of listening to the bell in the selected zone using button B You can also adjust the volume of the bell using the button QO to raise it and the button O to lower it 1201 0060 M ENS UEM Control console 1201 e a 8 E O Push button for talking Once the zone is selected and after pressing this button first the clock symbol a will appear while the pre warning tone sounds in the selected zone or zones The system is ready to broadcast a message when the icon appears Push button for accessing the Messages menu Once the zone is selected and after pressing this button you will be able to adjust the volume of the messages using the button O to raise it and the button O to lower it By means of push button number we can select if a pre warning tone will be played or not Music menu push button Once the zone is selected and after pressing this button you wi
13. dually until that raise cannot be perceived in front of the speakers REMEMBER If there is distortion in the sound of your installation it is probably caused by an excess of volume in your musical source 3 In the music source connected to the audio processor using direct audio signal outputs those that are not affected by a volume regulator like CDs radio tuners HI FI sound systems etc there is no need of regulation These direct audio outputs provide the best results and are usually called LINE OUT REC OUT TAPE CD or AUDIO E ME ET NENET UEM Garant a Edi garantiza sus fabricados electr nicos y electroac sticos contra cualquier defecto de fabricaci n que afecte a su funcionarriento durante 24 meses a partir de la fecha de su producci n indicada en cada fabricado comprometi ndose a reparar o reponer los m dulos defectuosos cuyo fallo siempre a juicio de Edi se deba a defecto de fabricaci n sin cargos de repuestos Esta garant a no incluye gastos de env o de m dulos ni mano de obra de sustituci n en la instalaci n de los citados m dulos electr nicos y electroac sticos En ning n caso la garant a cubre los desperfectos o roturas de piezas errbellecedoras rejillas errbellecedores car tulas marquillos Esta garant a se refiere nicamente al concepto de sustituci n en f brica de los m dulos producidos por eli excluy ndose cualquier otra cobertura o responsabilidad sobre el resto de materiales
14. itante correr con los gastos originados sin causa justificada de garant a ATENCION Si Vd observa alg n problerra en su instalaci n Edi nuestro Servicio de Atenci n al cliente le atender de 9h a 13h PREGUNTENOS EG I 6 40 53 53 0 consulte a su instalador habitual Guarantee Edi guarantees its electronic and electroacoustic products against any manufacturing defect that affects its operation for 24 months from the production date indicated in every manufacture taking the commitment of repairing or replacing the faulty modules which failure always to the discretion of Edi is caused by a manufacturing defect without any charge for spare parts This guarantee does not include charges for the shipping and handling of the modules nor the labour charges for the replacement in the installation of the aforementioned electronic and electroacoustic modules The guarantee will not cover in any case the damages or breakings of the trimming pieces lattices trims masks frames This guarantee refers only to the concept of replacement in factory of the modules produced by Egi excluding any other cover or responsibility on the rest of the materials or the whole of the installation that is put at the user disposal but that is not supplied nor executed by Edi A Therefore this guarantee does not cover a The fitting up and the interconnection between the modules b The results from the abuse or misuse of the product including b
15. l units and signal emitters microphone inputs and external musical sources or even intercommunicators between different zones Finally the speakers and acoustic diffusers will perform the diffusion of the sound messages signals or warnings with power and quality 27 MILLENNIUM Control console 1201 Once the Console is turned ON a menu will appear indicating the control keys for the zones zone 1 B zone 2 B zone 3 O and the dial position of the FM radio of the processor only if the processor includes a FM radio From this menu and after selecting one or several zones you will be able to decide what do you want to do with them emitting music warnings or signals Let us see each one of the control keys Door opener 1 Push button that activates the electromagnetic door opening mechanism selected as 1 This push button could manage any other output application using a relay Door opener 2 Push button that activates the electromagnetic door opening mechanism selected as 2 This push button could manage any other output application using a relay Push button for selection of zone 3 general line When it is pressed the symbol gt will appear to indicate that the zone has been selected If zone has been selected it is only possible to browse the bell and messages menus push buttons nr and O Push button for radio tuning When pressed you access to the FM tuner in the audio processor if it in
16. ll be able to adjust the volume of the music using the button to raiser it and the button Q to lower it By means of push button number B we can select channel 1 10r 2 FM If zone 1 has been wired in stereo the key will allow us the selection between mono and stereo Back to main menu push button When pressed it takes us back to the main menu Push button for selection of zone 2 When it is pressed the symbol will appear to indicate that the zone 2 has been selected Push button for selection of zone 1 When it is pressed the symbol lt will appear to indicate that the zone 1 has been selected Location of gooseneck microphone Location for the microphone with gooseneck only in 1201 11 version 1201 QOS DO O 8 Melb LE NN DIM pM M Audio processor 1301 This processor allows you to provide sound for facilities with 2 centralised zones plus 1 de centralised zone general line being these zones understood as the different areas which must be considered for message broadcast Version 1301 1 incorporates a FM tuner and a dual RCA input for external musical sources 1 ON OFF switch for the installation 2 Input for 1201 module Phone type input RJ45 for the connection of the 1201 control console There is also the possibility of connecting it internally Antenna input Coaxial input for FM antenna It enables the connection ofa FM antenna to imp
17. n SETUP O As long as we keep the button 1 pressed what is said to the microphone will be broadcast in all the zones belonging to group GRO Ifthe selected group is GENERAL the call will be broadcast in every zone of the installation Itis also possible to select several groups or zones or even acombination of groups and zones taking into account that if weentera group to select some of its zones the selection of that group as a whole unit will automatically be cancelled If the paging line is busy because another call is being broadcast or a pre recorded message is being played or saved from another console 1202 instead of the last two screens the following message will appear NENE ALAS NENEI UEM Control console 1202 Basic operation 1202 o Making a call when any of the targeted zones is in private mode If three groups for instance have been previously created e e e n n SETUP gt GRO1 And then the sign lt appears next to GR O1 If in the selected group any of the zones is in private mode e e g e n sEUP O If instead of a group a zone had been selected which was in private mode the name given to that zone would appear in the screen gt YES will send the message to the whole group gt gt NO will send the message only to the zones of the selected group which are not in private mode e e g o n n SETUP O e e e e
18. o el conjunto de la instalaci n puesta a disposici n del usuario pero que Bi no surrinistra ni ejecuta Por lo tanto no quedan cubiertas por esta garant a a La instalaci n e interconexionado entre sus m dulos b Las consecuencias de abuso o mal uso del producto incluyendo pero no lirritado a b 1 No usar el producto para fines nonrales o no seguir las instrucciones de Eli para el correcto uso y mantenimiento del mismo b 2 La instalaci n o utilizaci n de los productos de foma no concordante con las nomas t cnicas o de seguridad vigentes C Las aver as producidas por la incorrecta instalaci n de los m dulos o con cable que no sea el adecuado d Las aver as generadas por intervenci n de persona no autorizada por Eli e Las consecuencias de mezcla con equipos de otro origen as corro adaptaciones rrodificacio nes ajustes y o tentativas de ajustes irrespectivarrente de que ello haya sido efectuado de forma t cnicamente correcta en principio siempre que no exista expresa autorizaci n por gi f Las consecuencias de accidentes cat strofes naturales o cualquier causa ajena al control de Edi incluyendo pero no limitado al rayo agua y disturbios p blicos En todos estos casos excluidos de la garant a y siempre que los m dulos no sean juzgados corro defectuosos por parte de Edi SU remitente deber hacerse cargo del importe total de la reparaci n y caso de producirse visita de nuestros t cnicos su solic
19. of the message If reduced to 0 the message will be played in each target zone at the volume level that is set for paging there 1202 If the general access password is active the system will require us to introduce it every time we try to operate this module see point 2 of access restrictions Q Monitoring a message If three groups for instance have been previously created SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 P gt MESSAGE e e o n n SETUP gt msG 7 e e e e g n n a SETUP MONTOR plays the message number 7 if previously recorded by the built in speaker at the control console 1202 If the paging line is busy because another message is being broadcast or a pre recorded message is being played or saved from another console 1202 instead of playing the message the following message will appear 41 MEIE EEE NENEI UEM Control console 1202 Operation of the pre recorded message player o Recording a message If three groups for instance have been previously created BT e e e a SETUP O A SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 FE n
20. recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 dd EVENT1 4 EVENT 20r EVENTS and then the sign gt appears next to the selected option gt e Assigns message number 2 to no event orto event 1 2 or 3 depending on the previously pressed key 2 Broadcasting a message as a reaction o Selecting the destination of a message If three groups for instance have been previously created A SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 e e g o n sEUP O D gt MESSAGE P Ma3 e g e n SETUP O P e g n Mm SETUP n n SETUP gt assigns ZON 001 as first destination of message number 3 and leaves empty the three other possible destinations In order to assign a 2 3 or 4 destination move vertically the symbol with the 4 buttons on the right and select destination between the different zones and groups by pressing B or P When everything is according to our preferences we must press gt O Respecting or overriding the private mode of the zones If three groups for instance have been previously created SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system bu
21. rnal audio source RCA inlet for the connection of external audio sources 1106 1501 M tl LEN N UEM BLA 4 Channel 1 W Control unit 1205 ON OFF push button One press turns on and the next press turns off the sound system in that zone NOTE The control unit can be turned on at a moderate volume level by pressing V while the unit is still OFF Volume regulator To turn up A or down V the volume level of the control unit Channel selector This push button enables the user to select the sound channel that will be played in a zone Each push will change between the four available channels and the selection will be showed by the light of a red lamp Digital control keyboard 1206 ON OFF push button One press turns on and the next press turns off the digital amplifier which drives the speakers of that zone Volume regulator To turn up Aor down N the volume level of the digital amplifier to which the digital keyboard is connected Channel selector This push button enables the user to select the sound channel that will be played in a zone Each push will change between the four available channels and the selection will be showed by the light of a red lamp 47 1205 1206 amp MALE NN DEM SE ee 4 Channel 2 W Control unit 1207 Push button ON OFF One press turns on and the next press turns off the sound system in that zone The current statu
22. rove the reception of radio stations o Input for external music source RCA input for external music sources It enables the connection of an external music source CD cassette player etc 1301 00 Control console 1202 The control console 1202 is provided with a 4 line LCD display and a keyboard which allow the user to control and program all the possible functions The operation language can be selected between a total of six at the function menus The console enables also the control of up to four radio tuners installed in the 1316 audio processor The 127 different zones which can be controlled by the console can be grouped being 15 the maximum number of groups A name can be assigned to each zone or group of zones and the selected names must have no more than 7 characters like hall room 1 room 2 lift garage etc As many consoles as necessary can be used in the same installation up to 127 Push button for talking Push button for controlling audio programs Push button for controlling voice messages Set up push button Push button On Off of the console 000000 Push buttons for menu browsing 1202 MERTE NENEI UEM Control console 1202 Basic operation 1202 o Turning the system On and Off m semp If three groups for instance have been previously created AY 5 E Fl En m e Turning a zone
23. s O Changing the Public Address volume o Enabling and disabling the private Q Changing the pre warning tone of an 11 Changing the operation language level in a zone mode in a zone announcement If three groups for instance have been previously created e e e e n SETUP Y D GENERAL And then the sign lt appears next to GENERAL ZONE Provided that there are 3 numbered zones in the system e e e e a m SETUP O gt ZON 001 And then the sign lt appears next to ZON 001 A n e n SETUP O d or 4 modifies the volume level of the paging in the selected zone If three groups for instance have been previously created p 2 SETUP O gt GENERAL And then the sign lt appears next to GENERAL B ZONE Provided that there are 3 numbered zones in the system o e e e p SETUP O gt ZON 001 And then the sign lt appears next to ZON 001 A e e o O n seme O Do PRIVATE o o o n e sme O gt ENABLE or gt DISABLE enables or disables the private mode of a zone If three groups for instance have been previously created e o e mM SETUP O A SETUP Provided that the general access password is NOT active and there is NEITHER a pre recorded message player 1103 NOR a module for sending messages over the telephone 1104 in the system e e e e e e e e e e e 2 m su 6 g
24. s will be showed by the light of a red lamp Volume regulator To turn up A or down V the volume level of the control unit Channel selector This push button enables the user to select the sound channel that will be played in a zone Each push will change between the available channels up to a maximum of four and the selection will be showed by the light of a red lamp 1207 M I L L E N N 1 U M Adapting musical sources to the audio processors The audio processors allow nearly every type of audio source to be connected to them like cassette players radio tuners CD players HI FI systems compact HI FI satellite TV PC soundblaster etc For a correct operation of the set you should go through the following steps 1 Ask your installer to connect the musical device that you want to the audio processor 2 If the musical source has been connected to the audio processor by taking the signal from the loudspeaker output or from the headphones socket it is usally so in radio cassette sets compact systems walkmans etc you must set the volume at the music source at a proper level to prevent sound distortion caused by excessive volume Go through the following steps a Set the volume of the musical source to the minimum level b Ifthe musical source is a radio set tune a FM station and if it is a cassette CD player etc press PLAY to start the music playing c Turn up the volume level of the music source gra
25. sword for messages over the telephone The 4 bottom keys A 44 A SETUP and A U act here as numeric keys This password will have to be entered in the telephone keyboard whenever the user tries to broadcast a message over the telephone This will be requested by means of a set of commands recorded in the module 1104 The user will listen to these commands in his telephone handset after dialling the extension reserved for the Public Address system E hM 9E iE de IN s all OEN A Control console 1202 Operation of the pre recorded message player 1202 If the general access password is active the system will require us to introduce it every time we try to operate this module see point 2 of o Broadcasting a message at a definite time If three groups for instance have been previously created A SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 e e g e e e g e n SETUP O n SETUP E uoun or changes the hour MNUTE or changes the minute gt programs message number one to be launched at the selected time to an event access restrictions If three groups for instance have been previously created SETUP Provided that the general access password is NOT active and there is a pre
26. t BELL e e e e e e e g a SETUP O gt TONE 2 And then the sign lt appears next to TONE 2 changes the pre warning tone of the announcement If three groups for instance have been previously created A SETUP Provided that the general access password is NOT active and there is NEITHER a pre recorded message player 1103 NOR a module for sending messages over the telephone 1104 in the system e e e le o o e e e e e e n n SETUP LANG e e e e e e e e e o O O n SETUP O gt ENGLISH And then the sign lt appears next to ENGLISH changes the operation language NANNY If the general access password is active the system will require us to introduce it every time we Control console 1202 Advanced functions 1202 try to operate one of the advanced functions see point 2 of access restrictions e Checking the software versions Initialising the system gt YES If three groups for instance have been It is recommended to proceed with this previously created operation after the options described in points 1 and 6 If three groups for instance have been i e e eo e e e previously created LEO E LE E S dd p 2 ow o A SETUP Provided that the general access password is NOT active and there is SETUP NEITHER a pre recorded message 4 player 1103 NOR a module for Provided that the general access sending messages over the
27. t NOT a module for sending messages over the telephone 1104 a SETUP o5 e g o smP O 4 YES and then the sign gt appears next to YES ensures the broadcast of the message in ALL the destination zones wo and then the sign gt appears next to NO will only broadcast the message in those destination zones which are not in private mode MAIRENA al AU dA Control console 1202 Operation of the pre recorded message player o Replay of a message If three groups for instance have been previously created RE b A SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 P MESSAGE ducas En m En lt REPEAT Provided that message number 5 is already recorded m K 4 ES m atur lt INTERVAL ks 4 m mE Ei 4 4 Ie programs message 5 to be played 2 times with an interval of 1 minute between 2 repeats Changing the volume level of a message If three groups for instance have been previously created A SETUP Provided that the general access password is NOT active and there is a pre recorded message player 1103 in the system but NOT a module for sending messages over the telephone 1104 an de or 4 modifies the volume level
28. tact your usual installer 51 Fecha de instalaci n Installation date Electroac stica F Empresa instaladora Installer E E J
29. tem but THERE IS a module for sending messages over the telephone 1104 e e o e a mM SETUP O Ps rp modifies the telephone number 4 o d modifies the zone number assicn assigns the selected telephone number to the desired zone number If three groups for instance have been previously created e e e e n m SETUP O A SETUP Provided that the general access password is NOT active and there is NOT a pre recorded message player 1103 in the system but THERE IS a module for sending messages over the telephone 1104 e n 1 PHONE e e g o n SETUP n o lt d zone e e o o n sEUP O P rp modifies the telephone number 4 4 modifies the group number ssicN assigns the selected telephone number to the desired group number O Enabling and disabling the password for messages over the telephone If three groups for instance have been previously created e e e e a n SETUP o A setup Provided that the general access password is NOT active and there is NOT a pre recorded message player 1103 in the system but THERE IS a module for sending messages over the telephone 1104 lt d T PHONE e e g o n SETUP e e e e a SETUP O P No disables the password for messages over the telephone gt 1 gt 2 4 3 dail turn on the led lamp next to YES If then we press YES then the code 1234 has been enabled as pas
30. the devices which can be given a zone number will blink If in the mentioned devices one of the ZONE SET buttons is pressed that specific device will be identified as ZONE NR 1 and the system will get ready to assign number 2 10 the following device zone e e e e n mM SETUP O By following this procedure we can give consecutive numbers to all the zones of the installation without going back to the console 1202 this is useful for the initial configuration of the installation It is also possible to select a specific zone number by pressing Qs or C ana after pressing ZONE SET and following the ZONE SET button of the corresponding device the selected number will be given to that device this is useful to replace an old device by a new one which must have the same zone number without repeating the set up procedure e e e e a m SETUP O When a zone number has been assigned to all the zones of the installation we will quit the labelling procedure and all the ZONE SET led lamps of the different devices will stop blinking Now it is recommended to start up the system point nr 13 prior to label the zones with names o Labelling the zones with names If NO groups have been created yet e o e e a SETUP O P GENERAL And the sign lt appears next to GENERAL D gt ZONE If three zones for instance have been previously created e e o o a seme O B ZON001 And the sign lt appe
31. ts maximum 1105 1107 Melb SIL NN DIM ee Auxiliary Input 1106 Push button ON OFF One press turns on and the next press turns off the auxiliary input 1106 On lamp It lights when the module is activated by pressing the push button ON OFF or automatically when a signal coming from a previous module is passing through Volume regulator To turn up A or down V the volume level of the auxiliary input Pilot lamp for volume regulation It lights only when the module is activated locally but not when signals coming from other modules are passing through the auxiliary input It blinks when the volume level has reached its top Inlet for audio source An external audio source CD player cassette deck soundblaster etc can be connected here for local use A wireless microphone receiver can also be connected here Wall base for connection of control consoles and music sources 1501 This wall socket can be used to connect whether a control console or any external audio source to the audio processors 1301 or 1302 The two inlets that are present in the wall socket can be used simultaneously o Pilot lamp for RCA signal reception It lights when the RCA connectors are receiving an audio signal from an external music source which is over the minimum sensitivity threshold 2 Inlet for console Inlet type RJ45 for the connection of control consoles 1201 or 1202 Inlet for exte
32. ules of this type could be installed in one system Pre recorded message player 1103 1 It allows to save and to store in digital format up to eight messages The maximum length of each message will be of fifteen seconds Interface for telephone systems 1104 1x It allows the connection through an analogue extension of a telephone central unit By doing this it is possible to broadcast messages through any telephone handset 43 B MALL EN Nol UEM A 2 Channel 5 W Control unit 1204 Push button ON OFF On press turns on and the next press turns off the sound system in that zone NOTE The control unit can be turned on at a moderate volume level by pressing V while the unit is still OFF Volume regulator To turn up A or down V the volume level of the control unit Channel selector This push button enables the user to select the sound channel that will be played in a zone Each push will change between the two available channels and the selection will be showed by the light of a red lamp Intercom unit 1203 Push button to select zone 1 By pressing this push button a call will be made to zone 1 It is possible to talk to zone 1 as long as you keep on pressing the button Push button to select zone 2 By pressing this push button a call will be made to zone 2 It is possible to talk to zone 2 as long
33. ut not limited to b 1 Notusing the product for usual purposes or not following the instructions from amp i for the correctuse and maintenance of the product b 2 The installation or use of the products in a way that is not concordant with the technical or security rules now in force c The malfunctions caused by the wrong installation of the modules or by an installation with inappropiate cables d Themalfunctions caused by the intervention of a person non authorised by Edi e Theconsequences of mixing with equipment from other sources and also adaptations modifications adjustments and or adjustment attempts irrespectively of those that have been performed ina technically correct way provided that there is not an express authorisation by Edi r f The consequences of accidents natural catastrophes or any cause beyond Edi control including but not limited to lightning water and public disturbances In all these cases that are excluded from the guarantee and every time that the modules are not considered as faulty by Edi the sender should take responsibility of the full amount of the repair and in the event of a visit from our technicians the requesting person will bear the expenses originated without a cause justified in the guarantee WARNING If you notice any problem in your Edi installation our Customer Support Service will attend you from 9h to 13h Central European Time ASK US mei LE yc NP UNE Or con