1. METALLIC DIN RAIL CLIP DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT METALLIC NONMETALLIC B SHIELDED PATCH CABLE STP STP Note Strain relief boots not shown for clarity purposes In the event all CatSe patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals RJ45 CONNECTOR CRIMP SPECIFICATIONS R a Please reference the illustration for your Cat5 cable specifications mi CAT5e CABLE 0 237 0 005 686 02 0 13 EIA 568B CATSe CABLE Revised 2011 03 14 14 CONNECTING THE UNIT For FX FXE units remove the dust cap from the fiber optic connectors and connect the fiber optic cables The TX port located on the bottom connector on the FX FXE models should be connected to the RX port of the far end station The RX port located on the top connector on the FX FXE versions should be connected to the TX port of the far end station For 10Base T ports plug a Category 3 or greater twisted pair cable into the RJ45 connector For 100Base T ports plug a Category 5 or greater twisted pair cable into the RJ45 connector Connect the other end to the far end st
2. THE INDUSTRIAL NETWORK COMPANY 100 Series Media Converter amp Industrial Ethernet Switches User Manual amp Installation Guide Revised 2011 04 15 IN TRON THE INDUSTRIAL NETWORK COMPANY Industrial Media Converter and Ethernet Switch Installation Guide 102MC XX 105TX 106FX2 10O2MCE XX YY 105TX SL 108TX 104TX 105FX XX 108TX HV 105FXE XX YY Where XX ST or SC and Y Y 15 40 or 80 Revised 2011 04 15 110FX2 XX YY 111FX3 XX YY 112FX4 XX YY 114FX6 XX YY 116TX Copyright N TRON Corp 2011 820 S University Blvd Suite 4E Mobile AL USA 36609 All rights reserved Reproduction adaptation or translation without prior written permission from N TRON Corp 1s prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other product names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Contact In
3. Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude O to 10 000 ft Network Media 10BaseT gt Cat 3 Cable 100BaseT gt Cat 5 Cable 100BaseFX Multimode 50 62 5 125um Fiber Singlemode 7 10 125um Fiber Fiber Transceiver Characteristics Fiber Length TX PowerMin 19dBm 15dBm RX Sensitivity Max 3 dBm 31dBm 34dBm 34dBm Wavelength 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Connectors 10 100BaseTX RJ45 UTP Port 100BaseFX SC or ST Duplex Port Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 17 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified s FE CE 65SN Revised 2011 03 14 18 104TX 105TX KEY SPECIFICATIONS Physical Height 2 87 7 28 cm Width 1 49 3 78 cm oN I XONN Mess Depth 3
4. Operating Altitude Network Media 10BaseT 100BaseTX Connectors 10 100BaseTX 5 8 14 6 cm 2 0 5 1 cm 4 1 10 3 cm 1 Ib 1 oz 48 kg 35 mm 10 49 VDC Regulated 300 mA max 24VDC Steady State 40 C to 85 C 40 C to 85 C 10 to 95 Non Condensing O to 10 000 ft gt Cat3 Cable gt Cat5 Cable Sixteen 16 RJ 45 TX Ports Recommended Minimum Wiring Clearance Top 1 2 6 cm Front 2 5 1 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 Oper agbagn 16 ANKO 14 ACT 12 LNK RX 10 LNK act oe LNK acr 6 INK act 4 LNK B acr 2 LNK Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI ANSI C63 4 FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 4 Class A Emissions EN 55024 Immunity EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 PFMF EN61000 4 11 VDI FE CE Cc GOST R Certified UL us LISTED 65SN Revised 2011 03 14 38 N TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be free from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase f
5. 53 8 96 cm OG OY Weight 0 6 Ibs 0 27 kg DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated Input Current Inrush Current 215 mA max 24VDC Steady State 7 8 Amp 0 7ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude O to 10 000 ft Network Media 10BaseT gt Cat 3 Cable 100BaseT gt Cat 5 Cable Connectors 10 100BaseT RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified UL us LISTED 65SN FC CE Revised 2011 03 14 20 105TX SL KEY SPECIFICATIONS Physical Height 4 10 2 cm Width 1 2 6 cm Depth 3 7 9 2 cm Weight 0 7 Ibs 0 32 kg DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated
6. Environmental Surrounding Air Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseTX 100BaseFX Multimode Singlemode Connectors 10 100BaseTX 100BaseFX 4 3 10 8 cm 3 1 7 9 cm 4 6 11 5 cm 1 Ibs 9 oz 0 70 kg 35 mm 10 49 VDC Regulated 455 mA max 24VDC Steady State 40 C to 80 C 40 C to 85 C 10 to 95 Non Condensing O to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable 50 62 5 125um 7 10 125um Eight 8 RJ 45 TX Ports Four 4 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 33 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified W FE CE a 65SN Revised 2011 03 14 34 114FX6 KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Input Current Environmental Surrounding Air Temperature Storag
7. Input Current Inrush Current 215 mA max 24VDC Steady State 3 0 Amp 1 0 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude O to 10 000 ft Network Media 10BaseT gt Cat3 Cable 100BaseT gt Cat5 Cable Connectors 10 100BaseT Five 5 RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 21 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI ANSI C63 4 FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 4 Class A Emissions EN55024 Immunity EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 SURGE EN61000 4 6 RF EN61000 4 8 PFMF EN61000 4 11 VDI GOST R Certified 65SN Revised 2011 03 14 22 106FX FX2 KEY SPECIFICATIONS Physical oo Height 3 83 9 73 cm INPURKON Width 1 50 3 81 cm 106FX2 Depth 4 80 12 2 cm Weight 0 6 lbs 0 27 kg DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated Input Current Inrush Current 270 mA max 24VDC Ste
8. and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareillage num rique de la classe A r pond a toutes les exigences de l interf rence canadienne causant des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf rence qui peut causer l op ration peu d sir e Revised 2011 03 14 16 102MC MCE KEY SPECIFICATIONS Physical D INEJ RION Height 2 87 7 28 cm Width 1 49 3 78 cm Depth 3 53 8 96 cm Weight 0 5 Ibs 0 22 kg DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated Input Current Inrush Current 140mA max 24VDC Steady State 8 5 Amp 0 7 ms max 24VDC Input Ripple
9. polarity on unit Plug the Voltage Input Plug back into the top header Tightening torque for the terminal block power plug is 0 5 Nm 0 368 Pound Foot Revised 2011 03 14 12 All LEDs will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 12 28 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3A N TRON SWITCH GROUNDING TECHNIQUES FOR 100 SERIES 102MC 104TX 105TX 105FX 106FX2 and 108TX NONMETALLIC DIN RAIL MOUNT DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GROUNDING POINT DRAIN WIRE WITH LUGS CONNECTING SWITCH CHASSIS TO KNOWN GROUNDING POINT As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as shown here will ground the switch and the chassis The power leads from the power source should be limited to 3 meters or less in length If the use of shielded cables is required it 1s generally recommended to only connect the shield at one end to prevent ground loops and interfere with low level signals i e thermocouples R
10. use of repeaters The 114FX6 FXE6 has 8 10 100BaseTX RJ 45 auto sensing ports and 6 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 116TX has 16 10 100BaseTX RJ 45 auto sensing Each port is capable of auto negotiating 10 100 Mb and half full duplex communications Key Features Full IEEE 802 3 amp 100Base FX Compliance Extended Environmental Specifications Support for Full Half Duplex Operation LED Link Activity Status Indication Autonegotiation Autosensing Speed Duplex and Flow Control Up to 3 2 Gb s Maximum Throughput e Industry Standard 35mm DIN Rail Mounted Enclosure Revised 2011 04 15 6 PACKAGE CONTENTS Please make sure the package contains the following items 1 100 Series Media Converter or Ethernet Switch 2 Instruction Sheet Contact your carrier if any items are damaged UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present LASER SAFETY MCE and FXE models only 40 and 80 CAUTION CLAS
11. 0 days after N TRON receives the product N TRON shall not be responsible for any software firmware information or memory date of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT OPTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may not be available in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WH
12. 5TX and 108TX are affordable and share a small footprint Each switch is capable of auto negotiating 10 100 Mb and half full duplex communications The five port 1OSTX SL offers the same functionality and is distinguished by its ultra slim enclosure The 1O5FX FXE has 4 ports similar to the 104TX plus additional multimode fiber optic up link port s capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 106FX2 FXE2 has 4 10 100BaseTX RJ 45 auto sensing ports and 2 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 1 10FX2 FXE2 has 8 10 100BaseTX RJ 45 auto sensing ports and 2 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 111FX3 FXE3 has 8 10 100BaseTX RJ 45 auto sensing ports and 3 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 112FX4 FXE4 has 8 10 100BaseTX RJ 45 auto sensing ports and 4 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the
13. DC Steady State 8 0 Amp 0 7 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude O to 10 000 ft Network Media 10BaseT gt Cat 3 Cable 100BaseT gt Cat 5 Cable 100BaseFX Multimode 50 62 5 125um Fiber Singlemode 7 10 125um Fiber Fiber Transceiver Characteristics Fiber Length TX PowerMin 19dBm 15dBm RX Sensitivity Max 3 dBm 31dBm 34dBm 34dBm 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Wavelength Connectors 10 100BaseTX RJ45 UTP Port 100BaseFX SC or ST Duplex Port Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 21 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN 61000 6 2 IEC 61000 4 2 ESD IEC 61000 4 3 RS IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEC 61000 4 6 Conducted Disturbances GOST R Certified FE CE LISTED 65SN Revised 2011 03 14 28 110FX2 KEY SPECIFICATIONS Physical Heig
14. ICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS E
15. S 1 LASER PRODUCT Do not stare into the laser Revised 2011 04 15 DIN Rail Mounting Install the unit in a standard DIN rail Recess the unit to allow at least 2 of horizontal clearance for CATSe cable bend radius lt x To install the plastic clip units to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place To install the metal clip units to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place Revised 2011 04 15 To remove the plastic clip units from the 35mm industrial DIN rail place a flat head screwdriver into the release clip found at the bottom of the unit and apply downward force on the clip until it disengages from the bottom of the unit from the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the unit To remove the metal clip units from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the u
16. SSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary depending on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Delaware U S A Revised 2011 03 14 39
17. TD etc Cat5e cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches Revised 2011 03 14 The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when required The best noise immunity and emissions i e CE are obtained when the N Tron switch chassis is connected to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switches with metal brackets can be supplied with optional plastic brackets if isolation is required Users may run a drain wire amp lug from the screw provided on the back face of the enclosure In the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do so may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that there is no voltage difference between the power supply s negative output terminal and the chassis grounding point of the switch 110FX2 111FX3 112FX4 114FX6 and 116TX DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT 105TX SL
18. ady State 8 0 Amp 0 7 ms max 24VDC Environmental Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude O to 10 000 ft Network Media 10BaseT gt Cat 3 Cable 100BaseTX gt Cat 5 Cable 100BaseFX Multimode 50 62 5 125um Singlemode 7 10 125um Connectors 10 100BaseTX Four 4 RJ 45 TX Ports 100BaseFX Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 23 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI IEC61000 6 2 ENS5011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances EN61000 4 11 Voltage Dips and Interruptions GOST R Certified FE CE LISTED 65SN Revised 2011 03 14 24 108TX KEY SPECIFICATIONS Physical Height 3 5 8 89 cm R F Width 1 49 3 78 cm ETON Depth 3 53 8 96 cm Weight 0 7 lbs 0 31 kg DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated HV option 10 60 VDC Regulated Input Current 250 mA max 24VDC Steady S
19. al Input Voltage Input Current Environmental Surrounding Air Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseTX 100BaseFX Multimode Singlemode Connectors 10 100BaseTX 100BaseFX 4 3 10 8 cm 2 4 6 1 cm 4 6 11 5 cm 1 Ibs 5 oz 0 60 kg 35 mm 10 49 VDC Regulated 410 mA max 24VDC Steady State 40 C to 80 C 40 C to 85 C 10 to 95 Non Condensing O to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable 50 62 5 125um 7 10 125um Eight 8 RJ 45 TX Ports Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 31 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI FCC CEFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions FE CE Pc GOST R Certified UL us LISTED 65SN Revised 2011 03 14 32 112FX4 KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Input Current
20. ation Verify that the LNK LED s are ON once the connection has been completed To connect any other port to another Switch or Repeater use a standard Cat5 straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure you are supplying sufficient current for the version chosen Note The Inrush current will exceed the steady state current by 2X 3 Verify that Link LED s are ON for connected ports 4 Verify cabling used between stations 5 Verify that cabling is Category 3 or greater for 1 OMbit Operation SUPPORT Contact N Tron Corporation at TEL 251 342 2164 FAX 251 342 6353 Wwww n tron com N TRON_ Support n tron com Revised 2011 03 14 15 FCC STATEMENT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses
21. e Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseTX 100BaseFX Multimode Singlemode Connectors 10 100BaseTX 100BaseFX 4 3 10 8 cm 3 1 7 9 cm 4 6 11 5 cm 1 Ibs 10 oz 0 73 kg 35 mm 10 49 VDC Regulated 545 mA max 24VDC Steady State 40 C to 80 C 40 C to 85 C 10 to 95 Non Condensing O to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable 50 62 5 125um 7 10 125um Eight 8 RJ 45 TX Ports Four 4 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 J3 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions FE CE FG GOST R Certified UL us LISTED 65SN Revised 2011 03 14 36 116TX KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Input Current Environmental Surrounding Air Temperature Storage Temperature Operating Humidity
22. formation N TRON Corp 820 South University Blvd Suite 4E Mobile AL 36609 TEL 251 342 2164 FAX 251 342 6353 Website www n tron com Email N TRON_ Support n tron com Revised 2011 04 15 GENERAL SAFETY WARNINGS WARNING Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard WARNING Ifthe equipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized modifications to the unit WARNING Do not operate the unit with the end plates removed as this could create a shock or fire hazard WARNING Properly ground the unit before connecting anything else to the unit Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty See the grounding technique section of this user manual for proper ways to ground the unit WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnect the power and allow to cool 5 minutes before touching ELECTRICAL SAFETY WARNINGS WARNING Disconnect the power cable before removing the end plates WARNING Do not operate the unit with the end plates removed WARNING Do n
23. ht Width Depth Weight DIN Rail Electrical Input Voltage Input Current Environmental Surrounding Air Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseTX 100BaseFX Multimode Singlemode Connectors 10 100BaseTX 100BaseFX 4 3 10 8 cm 2 4 6 1 cm 4 6 11 5 cm 1 Ibs 5 oz 0 60 kg 35 mm 10 49 VDC Regulated 355 mA max 24VDC Steady State 40 C to 80 C 40 C to 85 C 10 to 95 Non Condensing O to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable 50 62 5 125um 7 10 125um Eight 8 RJ 45 TX Ports Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 29 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified W FE CE CG 65SN Revised 2011 03 14 30 111FX3 KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electric
24. nit URMK 1000 PM Most N Tron products are designed to be mounted on industry standard 35mm DIN rail However DIN rail mounting may not be suitable for all applications Our Universal Rack Mount Kit P N URMK may be used to mount the 100 Series enclosures to standard 19 racks and our Panel Mount Assembly P N 1000 PM may be used to mount the metal clip versions of the 100 Series enclosures to a panel or any other flat surface NOTE the 1000 PM will only work with the factory installed MDR metal clip options and it is not acceptable for the 116TX units Revised 2011 04 15 9 FRONT PANEL E NIRON 108TX zl a NIR hero 105EX NITRON 105TX ee NIRON C 1047X O NIRON 102Me a Sugg BARS W RS NARS e AE N TRON 114FX6 80 am ig w 4 From Top to Bottom SPD Speed LED LNK ACT Link Activity LED RJ45 Ports Auto sensing 10 100BaseT Connection O Green LED lights when Power is connected NOTE The top LED indicates Link Activity LNK ACT and the lower LED indicates Speed SPD status Revised 2011 03 14 10 LED s The table below describes the operating modes Color LNK ACT SPD Power is Applied Power is OFF Link established no Activity on cable O O B LINKING Link established Activity on cable O N OFF N OFF No link activity on cable N LINK is 100Mbp
25. ot work on equipment or cables during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty Revised 2011 04 15 4 HAZARDOUS LOCATION INSTALLATION REQUIREMENTS l 9 This equipment is suitable for use in Class I Div 2 Groups A B C and D hazardous locations or unclassified or non hazardous locations only WARNING Explosion Hazard Substitution of any component may impair suitability for Class I Division 2 WARNING Explosion hazard do not disconnect while the circuit is live or unless the area is known to be non hazardous and to be free of ignitable concentrations WARNING Explosion Hazard Do not remove or replace the device unless power has been switched off or the area is known to be non hazardous For 1O2MC 105FX 106FX and 108TX Use 60 75 C rated copper wire 0 22Nm 2 inch lbs tightening torque for field installed connectors For 104TX 105TX and 1O5TX SL Use 95 C rated copper wire 0 22Nm 2 inch lbs tightening torque for field installed conductors For the 116TX Use 105 C rated copper wire 0 22Nm 2 inch lbs tightening torque for field installed conductors WARNING Install only in accordance with Local amp National Codes of Authorities Having Jurisdiction Class I Div 2 Installa
26. rom N TRON or its authorized reseller If a product does not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 3
27. s FF O Link is 10Mbs APPLYING POWER 102MC 104TX 105TX 105FX 106FX2 108TX and 116TX Power Connector Top View CHASSIS GROUND V Negative GND Return V Positive 10 30VDC Vi Negative GND Return V Positive 10 30VDC DETAIL Revised 2011 03 14 11 e 110FX2 111 FX3 112FX4 and 114FX6 Power Connector Top View must be powered by Class 2 source only ray Vr VAV V Sanaaaa Unscrew amp Remove the DC Voltage Input Plug from the top header Install the DC Power Cables into the Plug observing polarity on unit Plug the Voltage Input Plug back into the top header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot All LED s will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V or V2 can be connected to power for minimal operation For redundant power operation V and V gt plugs must be connected to separate DC Voltage sources Use wire sizes of 16 28 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3 e 10STX SL Top View CHASSIS GROUND V Negative GND Return V Positive 10 30VDC Vi Negative GND Return V Positive 10 30VDC DETAIL Unscrew amp Remove the DC Voltage Input Plug from the top header Install the DC Power Cables into the Plug observing
28. tate Inrush Current 8 1 Amp 0 7 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude O to 10 000 ft Network Media 10BaseT gt Cat 3 Cable 100BaseT gt Cat 5 Cable Connectors 10 100BaseT Eight 8 RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 2011 03 14 25 Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only g The high voltage model is TUV approved GS per EN 60950 1 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified We FE CE LISTED 65SN a FEDA GO HV Model Only Revised 2011 03 14 26 105FX KEY SPECIFICATIONS Physical Height 3 83 9 72 cm NITRON P Width 1 49 3 78 cm 105FX lt O Depth 3 53 8 96 cm Weight 0 6 Ibs 0 27 kg RX DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated Input Current Inrush Current 270mA max 24V
29. tions require that power connections must be current limited at the power source with an in line fuse rated at 0 5A Class I Div 2 installations require that all devices connected to this product must be UL listed for the area in which it is installed All circuits must have a common disconnect and be connected to the same pole of the disconnect 10 Limited Operating Voltage 12 30V for Class I Div 2 installations 11 WARNING For Sealed Relay Device a Exposure to some chemicals may degrade the sealing properties of materials used in the sealed relay device b Recommendation It is recommended to inspect the sealed relay device periodically and to check for any degradation of the materials and to replace the complete product not the sealed device if any degradation is found Revised 2011 04 15 5 100 Series Industrial Ethernet Switches The 100 Series Unmanaged Industrial Ethernet Switches support high speed layer 2 switching between ports This series of switches are housed in a ruggedized aluminum enclosure and provide Category 5 compliant 10 100 BaseT connections for high performance network design and hub repeater upgrades All fiber products utilize the IEEE compliant SC or ST duplex connectors for fiber optic communications All 10 100Base TX ports utilize the RJ45 shielded connectors The 102MC MCE is a two port unmanaged media converter that converts 10 100BaseTX copper to 100BaseFX full duplex fiber The 104TX 10

Download Pdf Manuals

image

Related Search

Related Contents

User's Guide AB1771-C Network Master (Version 5.21)  décembre 2014 n° 18 - Communauté de Communes Douve Divette  こちら - ご利用の条件|取扱説明書|ケンウッド  Danby DUF1166W User's Manual  critérios de priorização para intervenções ao nível dos pmrr  MANUAL DE INSTRUCCIONES PARA LA LLAVE    Norton Ghost™ Benutzerhandbuch  UNICO ON-OFF 275661B.pmd  GUIDA DELL`UTENTE ABILITATO ALLA CONNESSIONE  