CD3000S-2PH Thyristor Unit

image

Contents

1. WARRANTY CONDITION Producer gives a 12 months warranty to its products The warranty is limited to repairing and parts substitution in our factory and does exclude products not properly used and fuses Warranty does not include products with serial numbers deleted The faulty product should be shipped to Producer at customer s cost and our Service will evaluate if product is under warranty terms Substituted parts remain of Producer property Fuses and Fuse Code for UL 200 kARMS Symmetrical A I C 200 kARMS Symmetrical A I C Qty ese cooe EH been vee rusecooe ate alan Ye ARMS ARMS A2sec 600 660Grbi0 16 16 145 600 660Grb10 16 16 145 600 660Grb10 32 32 74 CP URD 22x58 63 sa o ooo er ug 27x60 100 100 3210 a ee E ST 60 660 660 660 660 660 660 CP URQ 27x60 160 160 15000 660 Current I2T max Fuse and Fuse holder CODE 0 FuseCODE ARMS A2 sec FU1038 16A 100A Neut Eng CD3000S 2PH__10 100A 06
2. notify the carrier immediately Check that the product features shown on CD3000 cover corresponds to that ordered Before to switch on the unit be sure that The load current is equal or less than the max current of the thyristor unit The operating voltage is equal or less than the max voltage of the thyristor unit Verify the Fan Power Supply only for size S6 and S8 Mounting CD3000 unit should be always mounted in vertical position to improve air cooling on heatsink Maintain minimum distances in vertical and in horizontal as represented Don t install in proximity of hot elements and near units generating electromagnetic interferences When more units are mounted in the same cabinet provide air circulation as represented Sometimes it is necessary to provide a fan to have better air circulation CD3000S 2PH from 10A to 100A User s manual TECHNICAL SPECIFICATIONS General features A i Wi Stocking from 40 gei ire temperature to 100 C ype Simina from 30 to 40 C 10A 15A UL Listed ZMVV operating for higher temp e O oo Coe Wire Pin temperature consult derating curve UL Listed ZMVV _ Ea M6 Screw 70 8 8 0 1 Fork Spade Terminal Load isolation 2500Veff Copper Tube Crimp Lug Coe ane Socket PolymericV2 material aluminium Delay switch ON time 0 5 period Max Delay switch OFF time 0 5 period Max 25A S1 35A S4 10 8 MS Fan voltage a 45A S57 10 8 m6 Oae epee E
3. 4 30Vdc 20mA Max Logic input SSR ON gt 4Vdc Standard for size SO S1 OFF lt 1Vdc current 4 30Vdc 12mA Max Logic input SSR ON gt 4Vdc Standard for other sizes OFF lt 1Vdc 10A SO Logic input SSR 5 30Vdc 5mA Max 15A S1 0 50 low current oe 25A S1 oe 35A 54 0 50 18 l 6 10 ws F a 0 110Vac Input Series 45A S7 0 50 18 6 f 10 3 ES oe ae ee o oa S a a aa be E range Voltage current one cycle current thyristor range Voltage Ow o ov soov maen toms to maem ttomsee o FR voe 25A S1 24 480 1200 1200 150 230 15 610 47 70 6o 2500 35A S4 24 600 1200 1600 250 600 15 1800 47 70 88 2500 SO Si S4 S7 S8 4 5mm L 30 4 5mm L 65 mm 4 5mm L 65 mm 4 5mm L 65 mm 4 5mm o 0 o ol 0 ol o G fe Cy Cy eS o 00 O o o gsl 30 mm me ol a a ee eee CD3000S 2PH from 10A to 100A User s manual DIAGRAM OF CONTROL CONNECTION Size SO Size S4 S7 e S8 Fan Power Supply for size S8 N Input Input Ld SSR SSR Ld rs 110Vac 110Vac Ld 230Vac 230Vac rs POWER UNIT POWER UNIT y TO LOAD TO LOAD TO LOAD The user installation must be protecting by electromagnetic circuit breaker or by fuse isolator Load Type Wiring instructions Derating curve CD3000S unit has isolated heatsink For safety connect the _ K
4. USER S MANUAL cop3000 2PH Rev 05 2012 THYRISTOR UNIT from 10A to 100A 00003 Important warning for safety Thyristor units are used in power industrial equipment The voltages used in the Thyristor unit can cause severe electrical shock and could be lethal Don t remove the plastic cover Don t use this unit in aerospace and nuclear application Electric Shock Hazard Risque the choque lectrique When thyristor unit has been connected to main supply voltage and is switched off before to touch it be secure that the unit is isolated and wait at least one minute to allow discharging internal capacitors Thus be secure that access to thyristor unit is only permitted to specialised personnel the authorised personnel must read this manual before to have access to the unit the access to the unit must be denied to unauthorised personnel Important warnings attention Local regulations regarding electrical installation should be rigidly observed e Safety regulations must be rigidly observed Don t bend components to maintain insulation distances Protect the unit from high temperature humidity and vibrations Don t touch components to prevent electrostatic discharges on them Verify that all rating are in line with real needs If authorized personnel must measure voltage current etc on units take away rings and other jewels from fingers and hands Authorized personnel working on thyristor unit under power supply voltage m
5. heatsink to hearth using its terminal with hearth symbol MAX ENOM X CD3000S can be susceptible to airborne interferences from near equipment or from interferences on main supply so a number of precautions must be taken Contactors coils and chokes must have in parallel a RC filter and must be supplied with a different voltage line All input output signals must use screened bifilar wires Signal input and output must not route in same cable try and must not be parallel Local regulations regarding electrical installation should be rigidly observed Use copper cables and wires rated for use at 75 C only Use wire terminal UL Listed ZMVV Order Code CD3000S 2PH Operating Voltage Volt 10A Write 480Vac ZC Fan at 110Vac External Protection IP20 for size S7 and S8 External fuses and fuse holders 35A lt NF No fuses Current Firing Options 15A Operating 600Vac 110Vac EP 25A Voltage 230Vac EF 45A MAX Volt UL UL Certification 75A 100A 1 Only for size from 35A to 100A CD3000S 2PH from 10A to 100A User s manual FUSES AND FUSE HOLDER Size 15A 25A Size 35A Size 45A 75A CE WARNING CD3000S unit must be protected against short circuit by High speed fuses The fuses must be with proper I2t lower than the thyristor one The warranty of thyristor is null if no proper fuses are used High speed fuses are only used for the thyristor protection and can not be used to protect the installation
6. ust work on insulated board Be secure that board is not connected to earth This listing does not represent a complete enumeration of all necessary safety cautions Protection protection CD3000 thyristor unit has a polymeric plastic cover to compliance to International specification IP20 To understand if IP20 protection is sufficient should be evaluated the installation place Open Type Equipment Earth terre CD3000 family has isolated heatsink For safety connect the heatsink to earth to avoid shocks in case that circuit board or thyristor lose insulation Earth impedance should be correspondent to local earth regulation Periodically the earth efficiency should be inspected l Our thyristor units have an excellent immunity to electromagnetic interferences if all suggestions contained in this manual are respected In respect to a good Engineering practice all inductive loads like solenoids contactor coils should have a filter in parallel Emissions emission All thyristor switching at high speed generate some radiofrequency disturbance CD3000 series compliance with EMC rules for CE mark In many installations near electronic devices have not been noted problems If radiofrequency devices at low frequency are used near the thyristor unit some precautions should be taken like line Filters and shielded cables for input signal and for load cables Installation Before to install the CD3000 unit examine for damages or deficiencies If any is found