Home

operations

image

Contents

1. Air exchange switch 5 Air inlet grill outdoor side 6 Air outlet grill 7 Electronic control keypad 8 Power supply cord 9 Remote control Accessories EN Ze Seal Drain Joint Drain Tray Water outlet pipe Screw Used on drain joint Si O g rEg j F yD g 1 1 1pec 1 pec The unit displayed in manual are for representational purpose only Actual unit may vary FEATHER TOUCH 1 Power Key e Power button to ON OFF the Air Conditioner 2 Mode Key e Toggles between Auto Cool Dry Fan Modes 3 Temp Timer Adjustment Key e Adjust the temperature timer setting 4 Fan Speed Key e Toggles the Fan speed between High Low and Auto 5 Remote Sensor 6 Room Temp Display 7 Timer Key e Toggles between Timer ON and Timer OFF 8 Swing Key e To adjust the airflow direction DIPLAY UNIT TEMPERATURE TIME ADJUSTMENT CB ONIGEE TIMER ON OFF MODE ADJUSTMENT SWING ADJUSTMENT L S
2. Title Mr Ms Mrs M s Name Residence Address Dist Pin State Occupation ji RC Ret Fax Code Code Mobile No Email Product Details Please Tick The Appropriate Product Colour TV B amp W TV DVD Washing M C AC Plasma TV Rear Projection TV Microwave Oven LCD TV Dealer s Name amp Address Model No Serial No Please Refer Sticker On Back Cover Of Your Product Purchase Date Day Month Year Signature Bill No Accept The Terms And Conditions of The Warranty Customer Signature Thank you for selecting a World Class product and we assure you that it will perform as per your expectations We thank you for taking your time to complete this form All Information Provided by You will be Kept Confidential Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY Customer Code Branch Mirc Electronics Ltd Note Company Will Not Be Responsible For The Loss Of This Form During Transit For Other Details on Our Products amp Services Log On To www onida com BUSINESS REPLY ENVELOPE ONI
3. ONIDA O ONIDA O ONIDA M S MIRC ELECTRONICS LTD WARRANTS THIS ONIDA AIR CONDITIONER except the front grill knobs remote unit and add on plastic parts TO THE ORIGINAL PURCHASER TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP WITHIN ONE YEAR FROM THE DATE OF PURCHASE AS PROVIDED IN THE WARRANTY REGISTERATION CARD WARRANTY FOR COMPRESSOR MIRC ELCTRONICS LTD HEREAFTER WARRANTS TO THE PURCHASER OF THIS ONIDA AIR CONDITIONER THAT FOR A PERIOD OF SIXTY MONTHS FROM THE DATE OF INVOICE WE WILL REPAIR REPLACE THE COMPRESSOR WHICH PROVES UPON INSPECTION BY US OR ANY OF OUR AUTHORISED SALES DEALERS TO HAVE BEEN DEFECTIVE DUE TO MANUFACTURING DEFECT This warranty is subject to terms and conditions as mentioned below 1 This warranty shall be valid only for the said period of 12 months as specified above irrespective of whether the said unit has been in use or not for any reason whatsoever or the unit is moved from one location to another Warranty does not cover accessories external to the equipment The warranty period specified above shall include time taken for repairs replacements break downs transit time etc No notice of expiry period of warranty will be given by the company This warranty shall stand automatically terminated in the event of the said unit being serviced repaired installed de installed re installed or otherwise attended to by any person or organization or agency or
4. Warranty Registration System Help us to serve you better by registering your product for Warranty Web Register at www onida com Telephone Call Centre No OXX 39889000 0XX STD Code of State Capital Post Visit Post the Warranty Registration Card amp Service Centre Copy or Visit the Nearest Service Centre Fa USER MANUAL 3 STAR 2 STAR As per the Government of India s E Waste Management and Handling Rules 2011 implemented from 1st May 2012 the product purchased by you is to be considered as E Waste during it s disposal It cannot be disposed off With your general house hold waste but must be disposed through MIRC Electronics Ltd authorized Collection Center as to prevent any damage to The environment Please refer our website www onida com for details about our E Waste policy And list of Collection Center s We request you to make a note of the above details and support us in our endeavour to ensure an environmental friendly nation ONIDA MIRC Electronics Ltd Onida House G 1 MIDC Mahakali Caves Road Andheri East Mumbai 400 093 Model W182FLT W183FLT The Onida Ethos Putting customers at the center of our existence z ONIDA OWNER S PRIDE IMPORTANT e Please read this owner s manual carefully and thoroughly before installing and operating your room air conditioners e Please retain this owner s manual for future referenc
5. Number Unit Model Sr No Name of Serviceman Date Time Sign of Serviceman Customer Identification Number Unit Model Sr No Name of Serviceman Date Time Sign of Serviceman Preventive Maintenance Service 1 Date Customer Identification Number Name of the customer Installation address Phone Mobile Fax t E mail Unit model Serial Number Service report number Customer s Signature Name Preventive Maintenance Service 2 Date Customer Identification Number Name of the customer Installation address Phone Mobile Fax gt E mail Unit model Serial Number Service report number Customer s Signature Name Preventive Maintenance MIRC Electronics Limited Serial No Warranty Card Customer Copy Customer Details Title Mr Ms Mrs s Name Residence Address Dist Pin State Occupation Te Reg Fax Code Code Mobile No Email Product Details Please Tick The Appropriate Product Colour TV B amp W TV DVD Washing M C AC
6. The base fixing plate is not contained on some models Hold the handle of the base of the air conditioner firmly and pull the base package from the package along with all the machine parts Fix the outer case of the air conditioner to the installation Fore Wye Wall supports with screws supplied by the end user or by the local our Co dealer or authorized service center 6 Push the air conditioner into the outer case horizontally 7 Install the base fixing plate optional tighten the two Outer case Screws Air conditioner installation supports Figure 6 screws at the bottom or both sides of the outer case G A 8 Install the front board 9 Install the air return grids 10 Test running a Connect to power source b Check to see if the room temperature control and the function controls work properly c Check if the water drainage is smooth and unblocked d Check if there are any abnormal sounds during operations ONIDA Treatment of condensing water There are two ways to handle the condensing water Please make your choice according to your needs Treatment of condensing water Method I Block the drainage hole on one side of the unit base with a rubber stopper so as to let the condensing water flow out from the rear drainage hole of the unit as shown in Figure 1 1 Figure 1 1 Drainage hole ros 4 eee Q Sealing ring Ps Qe Water outlet tube R
7. Warranty null and void if i The Air Conditioner is not purchased from the authorized dealers of the company ii The Service Centre copy of warranty card is not received within 10days of date of purchase at the nearest Authorised Service Centre iii Any damage is caused by accident mishandling tampering with installation or negligence in following instructions of the user manual issued by Company iv Any damage is caused by improper electrical circuit outside the unit or by any defective electrical supply v Atany time during the warranty period if any part of the unit is tampered with altered repaired or serviced by any unauthorized person not being the authorized representative of the company or its authorized dealers vi The serail number of the unit or any part thereof is damaged defaced altered obliterated or tampered with or removal for any reason whatsoever viii The unit is unauthorisedly moved from its original place of installation or re installation None of the employees and or Authorized Dealers of the Company have any authority whatsoever to vary the terms and conditions of this warranty This warranty shall be deemed to have been issued at Mumbai state of Maharashtra and courts at Mumbai shall have exclusive jurisdiction on matters covered by or following from this warranty and the original purchaser alone shall have cause of action arising out of the transaction ONIDA Customer Identification
8. not put a heater etc with wet hands or flammable spray where is exposed to direct air flow It may cause an electric shock It may causea fire or deformation It may cause imperfect combustion of the cabinet Select the best location FENCE About 10mm About 10mm Over 50cm 75 150cm 75 150cem Over 50cm 1 To avoid vibration and noise make sure the unit is installed securely and firmly 2 Install the unit where the sunlight does not shine directly on the unit If the unit receives direct sunlight build an awning to shade the cabinet 3 There should be no obstacle such as a fence or wall withing 50cm from the back of the cabinet because it will prevent heat radiation of the condenser Restriction of outside air will greatly reduce the cooling and heating efficiency of the air conditioner 4 Install the unit a little obliquely outward not to leak the condensed water into the room about 10mm or 1 4 bubble with level 5 Install the unit with its bottom portion 75 150cm above the floor level 6 The power cord must be connected to an independent circuit The yellow green wire must be grounded All side louvers of the cabinet must remain exposed tothe outside of the structure ONIDA Installa
9. the fan mode Selected temperature is more than room temperature Air filter is not clean DTING CHART Suggested Remedy Reset MCB Replace fuse wire If the input voltage to the stabilizer is below the acceptable range the AC will not operate Press the On Off key on the control panel or the remote Remove all obstructions to make the airflow paths free Change to COOL mode Make the selected temperature less than room temperature Clean the air filter Note If the unit still does not work or if any other types of symptoms are encountered shut off the mains switch fuse unit and call the service engineer INSTALLATIONS SATISFACTION i D N Customer Name Address Phone O R Unit Model Unit Serial Number Dealer Name Invoice Number Date of Purchase Date of Installation MCB Rating Current Amps Cable Size Ambient Temp C Earthing Room Temp C Stabiliser Grill Temp C Input Voltage Remote Operation Customer s Response To be filled up by the Customer 1 Installation completed within 12hrs _ 24hrs 36 hrs more than 36 hrs 2 How did you find the behavior of the Engineer Excellent Good Not satisfied 3 Overall rating of the service Excellent Good Not satisfied 4 Suggestion if any Job Number Engineer s Signature Customer s Signature
10. DA CUSTOMER RELATION CENTRE Adonis Electronics Pvt Ltd Onida House II Mukund Ground Floor Mahal Industrial Estate off Mahakali Caves Road Andheri East Mumbai Maharashtra India 400093
11. LEEP FAN TIMER SLEEP 1 Open back cover and put 2 Nos AAA size alkaline batteries The remote signal can be reached up to six meters from the Air Conditioner Receiver 3 When the button is pressed on remote Unit will beep once indicating the receipt of signal If no beep sound is heard press the button once again Remove batteries if remote control has not been used for long time 5 Heat mode is not available with all models Operating Your Air Conditioner Your Window Air Conditioner can be conveniently operated using the intelligent cordless remote control 1 Switch on the MCB Press ON OFF button on remote handset to switch ON the AC All icons will glow once Your AC switches on with parameters that were set before power was switched off The unit receives the signal with BEEP tone and your AC starts operation Time Delay To protect the compressor a time delay is incorporated in the circuit The Time Delay ensures that the compressor switches ON only after a delay of about 3 minutes 2 Press the MODE Button for Auto Cool Dry or Fan selection 3 Press the FAN Button to set the Fan Speed Each press changes the fan speed from Low Med High Fan speed The selected fan setting symbol can be seen on the LCD 4 The Set Temp is displayed on LCD Press button A to increase and Vv to the decrease the temperature 5 To switch off the AC press the same ON OFF Button Setting the Desired Ro
12. Plasma TV Rear Projection TV Microwave Oven LCD TV Dealer s Name amp Address Model No Serial No Please Refer Sticker On Back Cover Of Your Product Purchase Date Day Month Wear Signature Bill No Accept The Terms And Conditions of The Warranty Customer Signature Thank you for selecting a World Class product and we assure you that it will perform as per your expectations We thank you for taking your time to complete this form All Information Provided by You will be Kept Confidential Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY Customer Code Branch Mirc Electronics Ltd Note Company Will Not Be Responsible For The Loss Of This Form During Transit For Other Details on Our Products amp Services Log On To www onida com MIRC Electronics Limited Serial No Warranty Card Service Centre Copy Customer Details
13. by the said purchaser himself other than the authorized representative of the company Parts of the unit replaced or repaired under the terms of this warranty are warranted only for the remaining period of the original warranty period For attending any service call under this warranty beyond the municipal limits of the locality in which the authorized representative dealer is situated outstation locations all to and fro travelling and other incidental expenses as prevailing from time to time incurred in connection with the visit of the service personnel technicians etc shall be borne by the said purchaser and shall be payable in advance Additionally all expenses incurred by the authorized representative dealer in collecting the said unit or any part thereof from such outstation locations and its return to the original location shall be borne by the said purchaser Any loss of refrigerant caused due to sabotage improper handling or treatment carelessness accident fire flood earthquake or any natural calamity any corrosive action on the original refrigerant pipes fittings valves etc for whatever reasons shall not be covered under this warranty In the event of any change in the location of the unit during the warranty period this warranty shall become null and void unless the fact of the proposed change is communicated in writing to the authorized dealer at least seven 7 days prior to the said change On receipt of such information th
14. choose back drainage or non drainage See the following procedures to perform back drainage 1 Fit the seal onto the drain joint which provided with your air conditioner accessory 2 Remove the rubber plug from the back of the unit 3 Attach the drain joint to the back of the cabinet where you remove the plug and rotate 90 to securely assemble them 4 Connect the drain joint with a extension drain hose Locally purchased Dos 4 Seal all air gaps in the room Choose the right temperature to avoid over cooling Ventilate the room regularly Switch off the power supply if not in use for long Unplug the unit while cleaning Don t s X Don t leave the doors and windows open when the air conditioner is on Don t use hot water to clean your front grill Don t use scouring powder harsh soaps wax or polish on the grill Don t switch on the air conditioner immediately after switching it off Wait for 2 minutes Don t operate with a clogged filter Don t block air intake amp outlet vents Don t change setting unnecessarily o TROUBLE SH Symptoms Unit does not start Units does not cool Even after the normal Time Delay of approx 2 3 minutes for compressor to start Possible Causes MCB has tripped Fuse has burnt Input voltage to the stabilizer is below acceptable range The On Off key is not pressed The airflow paths are not free The Units is in
15. d Plug in the power plug properly e Otherwise it will cause electric elt will cause electrical shock or fire elt will cause electrical shock or fire shock or fire due to heat due to heat generation e If the supply cord is damaged it generation or electrical shock must be replaced bya special cord or assembly available from the manufacture r or its service agent Do not modify power cord Do not operate with wet length or share the outlet hands or in damp with other appliances environment e Itwill cause electrical shock or It may cause electrical shock e Thi s could damage your health fire due to heat generation Never touch the metal parts Do not clean the air Ventilate well when used conditioner with water together witha stive etc the filter ltmay cause an injury Water may enter the unitand An oxygen shortage may occur degrade the insulation It may cause an electric shock When cleaning the unit first Do not puta pet or house Do not use for special make sure the power and plant wher e it will be purposes breaker are turned off exposed to direct air flow e Since the fan rotates athigh This could injure the pet or plant Do notuse this air conditioner to speed during operation it may preserve precision devices food cause an injury pets plants and art objects It may cause deterioration of quality etc Do not operate Switches Do not apply an insecticide Do
16. e authorized dealer or any of its counterparts shall arrange for de installation of the said unit on chargeable basis However in the event of any damage occuring to the unit or to any of its parts during the course of its transit by the said purchaser repair or replacement the said unit or any part thereof damaged shall not be covered by this warranty ONIDA 10 11 12 13 14 It shall be the absolute discretion of the company to a effect the repairs or replacement of parts whether at the site of installation or at any service centre and b have the job attended to either by the Company s service personnel or its authorised dealer This warranty is in the nature of and for the purpose of set forth herein above and in particular the Company shall not in any event be liable for direct indirect incidental or consequential loss or damages to either the said purchaser and or his property or any other third party The AC is designed to operate at arange 230V 10 Any failure due to operation of the machine beyond these limits will not be covered by the above warranty Customer shall ensure that a stabilizer is installed in those areas where voltage is not available within the warranty range 230V 10 The stabilizer should be of any reputed manufacturer tested and recommended by the Company The purchaser should preserve the original invoice for necessary verification and produce as and when required
17. e AUTO COOL DRY FAN modes and stop when cool mode is selected 2 symbol can be seen on the Remote panel amp LED will glow on display panel when you select the cool mode In this mode you can change the temp settings by pressing and F temp buttons You can change the fan speed setting by pressing FAN button 3 If the Room temp is more than the set temp then the compressor will remain ON and perform the Cooling operation If the room temp achieves the temp less than set temp then the compressor will remain OFF The DRY Mode In the DRY mode your AC reduces the humidity within the room faster 1 Press MODE button to cyclically step through the AUTO COOL DRY FAN modes and stop when DRY mode is selected 2 symbol can be seen on the Remote panel amp LED will glow on display panel when you select the DRY mode 3 In DRY mode Temperature and FAN Speed cannot change Default pre set temperature is 25 C FAN will run at low speed Compressor work as per the Temperature difference ONIDA The FAN Mode 1 Press MODE button to cyclically step through the AUTO COOL DRY FAN modes and stop when FAN mode is selected 2 symbol can be seen on the Remote panel amp LED will glow on display panel when you select the FAN mode 3 In FAN mode only FAN will run at set speed and Compressor will remain off Temperature will be displayed on display panel Temperature setting can be changed 4 In this mode
18. e after reading it thoroughly Dear customer Congratulation on buying ONIDA Air Conditioner Your Air Conditioner comes with ONIDA Guarantee of Quality as detailed in the manual ONIDA takes great pride in providing its customers with state of the art products that adheres to international quality standards ONIDA is committed to following quality policy laid by our chairman and managing director Mr G L Mirchandani We are committed to quality and strive for continuous improvement through innovation and human development to give customer better value for money always ONIDA stands committed to provide the ultimate customer satisfaction as nothing brings us greater joy than having satisfied customers of ONIDA At ONIDA feedback and suggestions based on your product usage experience is greatly appreciated Please contact to us at response onida com Dr Y V Verma Chief Executive Officer The Onida Ethos Understanding customer lives dreams and aspirations better than anyone else z ONIDA OWNER S PRIDE Salient Features Inside Air Conditioner Control Panel Remote Overview Operations Safety Precautions Installation Electrical Requirements Take care of your Air Conditioner Precautions to be taken Trouble Shooting Chart Installation and Satisfaction Report Warranty Terms amp Conditions Preventive Maintenance Service Coupon Warranty Card Customer C
19. ealing strips on the housing remain in position 2 Connect the air conditioner to the power and position excess cord length beneath the air conditioner base 3 Engage the chassis fixing brackets into the bottom housing rail and secure to the base with the screw provided 4 Remove the front panel from it s carton and plastic bag and fit as per the installation instruction Switch unit on Check for operation of the unit and check for vibration in the installation 6 Fit the drain pan to the housing and run a drain line to a suitable location if required ao FLASH OR SEAL AROUND EXTERNAL WALL FRAME ORARCHITRAVE ENSURE LOUVRES ARE ENTIRELY OUTSIDE THE WALL F STURDY TIMBER DRAIN PAN FRAME STEADYING BRACKET TIMBER FRAMED ONE PER SIDE WALL OR PARTITION ISS SOLID TIMBER SUPPORT Alternative method of installation if external support cannot be provided Installations of the unit into the wall 45 BRICK CUT AWAY TO CLEAR LOUVRES 45 BRICK CUT AWAY t TO CLEAR LOUVRES FRONT LOUVRE y y 00mm minimum OPTIONA AIR OUT OPTION B ONIDA Installation Steps Pull out the Air return grids and remove three screws on the front board then take off the front board Figure 1 Air return grids 4 Front board Figure 3 Remove the two screws at the bottom or on both sides of the Figure 2 a Remove the base fixing plate optional steps
20. om Temp You can set the temp at which you would like your room to be Press button to increase the set temp On every press the temp increases by 1 C Press wy button to decrease the set temp On every press the temp decreases by 1 C The two digit display shows the set temp on LCD The setting temp range is from 16 32 C Your window AC operates in one of four modes AUTO COOL FAN DRY The modes button cyclically chooses between these operating modes Cooling capacity measured at High speed as per IS 1391 1992 Part 1 Your Window AC operates in one of four modes AUTO COOL DRY FAN The modes button cyclically chooses between these operating modes The AUTO Mode 1 Press MODE button to cyclically step through the AUTO COOL DRY FAN modes and stop when AUTO mode is selected 2 A symbol can be seen on the Remote panel when you select the AUTO mode 3 In this mode the fan speed can be changeable 4 Temperature can be pre set in this mode default temperature is 25 C 5 Inthe AUTO mode your AIR CONDITIONER Thinks for you The unit automatically and continuously monitors the difference between room temp and set temp and adjusts the fan speed accordingly to ensure maximum comfort The COOL mode In the cool mode the compressor is in operation and your AC functions in the standard operating mode cooling your room to the desired set temp 1 Press MODE button to cyclically step through th
21. opy Warranty Card service Center Copy The Onida Ethos Delivering products that enrich customer lifestyle reliably stylishly and thoughtfully z ONIDA OWNER S PRIDE 1 5T Window Air Conditioner Model Code W182FLT W183FLT Aesthetics a Unique Flat Panel Performance a 3 Star 2 Star Energy Saver BEE Rated b High BTU Compressor d Large Condenser Coil Trapezoidal Inner Grooved Tube Features a Combined Timer b Auto Restart c Multi Fan Speeds d Full Function LCD Remote e Gold Fin Safety amp Reliability a Low Deration Factor b Hydrophilic Fins for Evaporator c 5 Stage Epoxy Polyester Painting d Rugged Construction With Thicker Gauge Steel Because there are many models feat pattern Others please refer to using m tures and appearance will vary we only introduce the follow Left Right air fins 1 Front panel 2 Air filter 3 Frame 4 Cabinet
22. r 7 20 gauge The MCB for the air conditioner should not be rated less than 20 Amps The meter to which your air conditioner line is connected should have at least a 20 Amp rating Wire ends should be tightened fully Your air conditioner operates at a voltage of 230 V AC 10 In case your area experiences voltage fluctuation please use a suitable voltage stabiliser as per the table below Tonnage of your Voltage Stabilizer Air conditioner Rating 1 0 Ton 3 KVA 1 5 Ton 4 KVA ONIDA e PRECAUTION Air Filter The air filter behind the inlet grill should be checked and cleaned at least once every 2 weeks or as necessary to maintain optimal performance of the air conditioner How to remove the air filter 1 Hold the slot under the front panel then uplift it outwards and remove the front panel 2 Pinch the handle under the air filter and make the air filter arched remove it from the slot from underside to upside 3 Clean the filter with warm soapy water The water should be below 40 C to prevent distortion of the filter 4 Rinse off and gently shake off excess water from the filter Allow the filter to dry before replacing it To prevent distortion of the filter do not dry in direct sunlight To meet different requirement of different type of air conditioner there are two kinds of methods for your choice to treat the condensed water For Cooling Only Models You can
23. t will goes off Press again to cancel SLEEP operation NOTE The SLEEP function is only available under COOL and AUTO Modes only SWING Operation Press SWING button to adjust the airflow direction Press it again to stop Vent Control The Vent control is located above the control knobs The operation is different on different models see below figures For maximum cooling efficiency CLOSE the vent This will allow internal air circulation OPEN the vent to discharge stale air RS lt CLOSE a VENT OPEN CLOSE OPEN To open the vent pull the lever toward you To open the vent set the lever to the right position To close it push it in To close it set the lever in the left position Vertical air flow adjustment manually To adjust vertical air flow direction adjust any one of the horizontal louver blades When adjusting the horizontal louver blades up and down always keep the top or bottom blades horizontal This can effectively prevent water droplets condensing on the front panel of the unit To prevent injury to the user or other people and property damage the following instructions must be followed e Incorrect operation due to ignoring of instruction will cause harm or damage the seriousness is classified by the following indications Do not operate or stop the unit by inserting or pulling out the power plug Do not damage or use an unspecified power cor
24. tion of the Housing Step 1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to installation Steps Step 2 Prepare the hole in the wall so that the bottom of the housing is well supported the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B Holes from the outside through to the cavity should be sealed The housing should slope down towards the rear by about 5mm to allow water formed during operation to drain Step 3 Install the housing into the wall and secure Ensure the foam seals are not damaged Flash seal or fill gaps around the inside and outside to provide satisfactory appearance and protection against the weather insects and rodents FLASH OR SEALAROUND EXTERNAL WALL FRAME OR ARCHITRAVE r DRAIN PAN EXTERNAL SUPPORT FRAME AT BALANCE STURDY TIMBER FRAME ALL ROUND UNIT POINT OF A C ALTERNATIVELY BRACKETS TIMBER FRAMED AS ILLUSTRATED BELOW WALL OR PARTITION MAY BE USED NAN iit AAN SISIKII W Preferred method of installation into a timber framed wall partition or window NOTE UNIT MAY BE SUPPORTED BY A SOLID FRAME FROM BELOW OR BY AHANGER FROM ASOLID OVERHEAD SUPPORT ONIDA Installation of the unit into the Housing 1 Slide the unit into the housing until it is firmly against the rear of the housing Care is required to ensure the foam s
25. ubber stopper a When this method is adopted the condensing water in the base plate cannot be drained completely The remaining water may improve the heat dispersing effect of the unit but with louder noise b Installation of drainage tube Install the sealing ring to the drainage tube and align the tube with the rear drainage hole of the unit and turn the water outlet connecting tube for 90 degrees and then clamp it firmly Figure 1 2 Figure 1 1 Figure 1 2 Water outlet tube Extended water tube Method Il The condensing water flows out from the drainage hole at the base plate of the unit a When this method is adopted the condensing water in the base plate can be drained completely which helps to prevent from rusting There will be no noise of water splashing But the air conditioner has to n Drainage hole be raised to a certain height in installing so that the Water containing Pie AS Rubber stopper water containing plate can be placed between the 7 base of the unit and the supporting platform Bi b Installation of the water containing plate Use a rubber stopper to block the drainage hole at the rear of the unit and place in the water containing plate Figure 1 3 Figure 1 3 The unit displayed in manual are for representational purpose only Actual unit may vary ONIDA Electrical requirements Wiring up to the location of the air conditioner should be as unde
26. you can change the FAN Speed TIMER Operation You can program your AC to switch itself ON or OFF at particular time Maximum set time is 24 hrs with 1 0 hr increment ON TIMER When the AC is OFF in standby press TIMER Button on remote to use this feature as the TIMER make sure that MCB switch is ON The TIMER light on Display panel will glow ON For EXAMPLE Suppose you want to switch ON the AC after 8 hrs Press TIMER button when AC is in OFF condition Press TIMER button to set ON timer Display on Remote will show 8 OFF TIMER When the AC is ON press TIMER Button on remote to use this feature as the TIMER The TIMER light on Display panel will glow ON For EXAMPLE Suppose you want to switch OFF the AC after 8 hrs Press TIMER button when AC is in ON condition Press TIMER button to set OFF timer Display on Remote will show 8 CANCEL TIMER If you want to cancel either TIMER ON or TIMER OFF press the TIMER button till the timer becomes blank ONIDA NOTE Upto 10 hrs setting time increment will be 0 5 hrs after 10 hrs setting time increment will be 1 hrs SLEEP Operation To switch on SLEEP operation Press SLEEP button on remote In this mode the set temperature will increase by 1 C over the next 1hour and by another 2 C after an additional 1 hour This new temperature will be maintained for 5 hours before it returns to the original selected temperature Then uni

Download Pdf Manuals

image

Related Search

operations operations operations manager operations manager jobs operations synonym operations manager salary operations manual operations research operations center operations manager job description operations specialist operations definition operations coordinator operation sports operations hero operations siege codes operations center john deere operations director operations manager jobs near me operations hero login operations department operations 1 operations executive operations research pdf operations management research operations pace

Related Contents

Télécharger en PDF  Campus Culture  Bedienungsanleitung Sesam 800 Mobile Winden, 943549  gigabeat V401/V801 取扱説明書  MapPro80_User Manual Addendum  +7( 0  PRECAUCION - PBI  Samsung 400EX Керівництво користувача  T100™ Thermal Cycler  9525711-3B HJA-310LA_IM_PT_R15.indd  

Copyright © All rights reserved.
Failed to retrieve file