1. Cygnus DIVE Underwater Ultrasonic Thickness Gauge Divers wrist mountable thickness gauge with a large bright AMOLED display oe i h p Baad Ww L Simplicity thro CYGNUS INSTRUMENTS ugh technology Designed for the Professional Diver The Cygnus DIVE is a wrist mountable simple to operate robust underwater ultrasonic thickness gauge which provides an invaluable free hand while performing remaining metal thickness measurements The large bright colour AMOLED display is easily viewable by both the diver and his camera even in the poorest visibility and the operation of the gauge couldn t be simpler only two buttons for easy navigation of the intuitive clear menus Key Features e Wrist mountable giving the diver a free hand e Large bright colourAMOLED display highly viewable by diver and camera in poor visibility e A Scan display to assist with measurement verification e Auto Log Data Logging option no log button to press stores up to 5 000 measurements with A Scans e Multiple Echo means no need to remove protective coatings up to 20 mm 0 787 thick e Error checked Multiple Echo measurements to ensure genuine verified measurements are displayed e Deep Coat mode to measure through coatings up to 20 mm 0 787 thick e Single Echo mode with Twin Crystal probes e Probes are connected to the DIVE with a coiled double jacket cable which will extend up to 1 metre 3 ft
2. e Pressure tested to 300 metres 1 000 ft e Rechargeable Lithium lon battery giving up to 11 hours continuous operation MSI Measurement Stability Indicator Measurement Stability Indicator MSI has been built into the single echo measuring _ mode that uses twin crystal probes The gauge changes the colour of the thickness reading numbers from red to yellow to indicate a stable reading Although measuring in single echo mode is new to Cygnus MSI ensures that Cygnus s long established philosophy of providing accurate and reliable thickness readings Is carried through into the single echo measuring mode Twin Crystal and Single Crystal Probes Twin Crystal Probes Twin crystal probes measures in echo echo and single echo modes and is used on un coated surfaces This adds versatility for specific applications such as on extreme front and or back wall corrosion anchor chains links and plastic outfall dredge pipes Single Crystal Probes Single crystal probes use the Cygnus Multiple Echo technique which gives three sound pulses this ignores coatings and provides error checked verified readings Applications Maintenance and safety checks of metal thickness for Ships hulls e Semi sub structures Anchor chains e Subsea pipelines Offshore structures jackets e Storage vessels FPSO s Dock gates piers jetties and pipings plus many more Options and Accesso
3. 44 0 1305 269960 Email sales cygnus instruments com YouTube www youtube com user CygnusInstrumentsLtd Website www cygnus instruments com Technical Specifications Display Battery Measurement Modes Deep Coat Probes Probe Cables Measurement Ranges Measurement Resolution Measurement Units Probe Zero V Path Correction Velocity Range Pulser Receiver Amplifier Data Logging Data Output Computer Software Warranty 2 8 quarter VGA color AMOLED 320 x 240 pixels Large clear thickness measurement 15 mm 0 591 high numbers viewable from all angles A Scan display with automatic X axis Battery level signal strength probe type velocity Measurement mode and units indication Single 3 6V Li ion 8 2 W battery 11 hours continuous measurement Low battery warning alert message Multiple Echo three back wall echoes using Single Crystal zero degree probes automatically ignores surface coatings and measures only metal thickness Single Echo first back wall echo using Twin Crystal probes In Multiple Echo mode allows measurement to be made through thicker coatings of suitable materials of up to 20 mm 0 787 thick Single Crystal Probes e 2 25 MHz 13 mm 0 512 S2C standard e 2 25 MHz 19 mm 0 748 S2D e 3 5 MHz 13 mm 0 512 S3C e 5 0 MHz 6 mm 0 236 S5C Twin Crystal Probe e 5 0 MHz 8 mm 0 315 T5B standard Double outer jacket in tough PU Coloure
4. d yellow for easy locations underwater Coiled for ease of use Fischer S105 series connectors Multiple Echo through coatings with Single Crystal Probes e 2 25 MHZ 3 0 to 250 mm 0 110 to 9 995 e 3 5 MHz 2 0 to 150 mm 0 065 to 6 000 e 5 0 MHz 1 0 to 50 mm 0 045 to 4 000 Single Echo with Twin Crystal Probe e 5 0 MHz 1 5 to 50 mm 0 098 to 6 000 in steel Multiple Echo with Single Crystal probes 0 1 or 0 05 mm 0 005 or 0 002 Single Echo with Twin Crystal probes 0 1 or 0 01 mm 0 005 or 0 0004 mm or inches Fully automatic probe zeroing for all probes types Automatic V Path correction for all Twin Crystal probes 2000 to 9000 m s in 1 m s setps 78740 16 to 354330 71 in s in 39 37 in s steps Twin channel 70 V spike pulser 10 MHz bandwidth 120 dB range automatic TCG 60 MHz measurement time base One handed automatic logging of stable measurements Capacity for up to 5000 points including 640 point A Scan data RS 485 single pair half duplex for surface connection CygLink allows remote logging and viewing of A Scan graphs Survey and report generation to PDF file Graphic analysis of data and statistical calculations Designed for Windows 7 and Windows 8 3 years on gauge and 6 months on probe CYGNUS INSTRUMENTS lt A AS Manufactured in the UK CBO7UK ISS 6
5. ries Data Logger Adds data logging capability to the gauge measurements can be recorded in a linear or grid format CygLink Sofware A Windows application which has two functions used to transfer information from a data logging gauge to a computer and can be used to provide a top side view of the survey Topside Repeater Remote Display Kit Remote display unit connected to the DIVE gauge displaying the thickness measurements at the surface in real time during the survey Topside Repeater with Video Overlay Overlays real time thickness measurement on to a composite video signal displaying it on the monitor screen video recording of the survey HelmetView Display Remote display with fixing bracket for Kirby Morgan helmets with an accessory mounting point Standard Kit Content Cygnus DIVE gauge 2 rechargeable batteries Fast charger Multiple Echo through coating probe 2 25 MHz 13mm 0 512 User manual Spare membranes Membrane key Test block Surface and membrane couplant Contact Details Cygnus Instruments Ltd Facebook www facebook com cygnus instruments Cygnus House 30 Prince of Wales Road Google https plus google com cygnusinstruments Dorchester Dorset LinkedIn www linkedin com company cygnus instruments lItd DT1 1PW United Kingdom Pinterest www pinterest com cygnusndt Tel 44 0 1305 265533 Twitter https twitter com CygnusNDT gauges Fax

Download Pdf Manuals

image

Related Search

Related Contents

EN - TV-SmartTV-500 - Manual Android 4.2  USER MANUAL – EN IN 7845 Elliptical Trainer inSPORTline  HDS 698 C - hidrokar  RCA 31-5030 Home Theater System User Manual  Samsung L77 User Manual  PR612 and PR622 Installation guide Rev.B  Use and Care Manual  Uno User Manual and Troubleshooting Guide  TOPO - Thermo Fisher Scientific  Warning - Folke  