Home

Electrically adjustable table base frame Type ELS3

image

Contents

1. Make sure that you use the matching screws when installing the foot section Observe the maximum torque of 10 Nm of the A screws Each of the foot tubes has a base plate with 4 mounting holes gt Screw the foot sections onto the feet tubes of the lifting columns with 4 A screws each Table base frame ELS3 20 4 9 4 CAUTION 4 5 9 4 9 6 DANGER A Table base frame ELS3 SUSPA gt Screw the adjustable feet to the foot sections Step 4 Fasten controller to the table top The controller must be fastened in a position that allows all lifting columns to be connected by the motor cable The controller must always move with the lifting columns on their travel path We recommend fastening the controller to the bottom of the table top gt Select the matching screws gt Fasten the controller to the drilled holes provided on the bottom of the table top close to the frame 2 fastening points Step 5 Fasten manual switch to table top gt Select the matching screws gt Fasten the manual switch in the desired position on the table top Step 6 Connections with controller Mortal danger through cable breakage or damage to the cable In case of cable breakage or damage to the cable there are dangers to life and limb or property damage caused by electric shock Never operate the table base frame with a damaged mains cable Only use the supplied mains cable
2. Do not pull the cable across sharp edges Do not bend the cable Do not place heavy objects on the cable Do not pull on the cable Pull the mains plug to disconnect the table base frame from the power supply 21 WARNING A CAUTION DANGER A DANGER WARNING A Table base frame ELS3 SUSPA Immediately disconnect the controller from the power supply at any sign of cable breakage Please contact your specialist dealer Danger of falling Excess cables and wires as well as edges can cause a risk of stumbling Avoid having loose excess cables laying around and use cable ties if necessary Check all connections Make sure that the cable is routed safely when the table is adjusted Danger by improperly connected power cable An improperly connected power cable can cause a fire or an electric shock Operate the controller only at the mains voltage indicated on the nameplate Do not use a power source with high voltage or DC voltage Carefully check the power source Make sure that the mains cable is connected correctly Danger due to moisture and water Moisture and water in the vicinity of the controller or the mains cable may cause an electric shock or a malfunction Do not touch or grip the mains plug with wet hands Do not allow moisture and water to reach the controller or power cables Danger of crushing injury to hands or damage The movements of the lifting columns can cause injury lf there are people
3. conditions can lead to malfunctioning or render the table base frame unusable Use the table base frame only in the specified temperature range Avoid high humidity and prevent the table base frame from making contact with water Only qualified personnel such as your specialist dealer may repair the table base frame when used in incorrect operating conditions Danger of injuries and interruptions in operation by improper use There are risks posed by improper or unprofessional use of the table base frame Use the table base frame only for the purpose intended Additional information The provisions of the accident prevention regulations of the employer s liability insurance association are basically applicable to all work on the table base frame Observe and follow the following rules and regulations too m applicable binding regulations on accident prevention m applicable binding regulations at the place of use m approved technical rules for safe and professional work m existing environmental protection regulations m other applicable regulations Installation Follow safety chapter Observe and follow the Chapter General safety instructions from page 9 gt Check the delivery for completeness damage or anything else that is conspicuous Table base frame ELS3 11 SUSPA gt Observe the applicable safety and accident prevention regulations during transportation gt Contact details can be found in the Chapter Ide
4. extracted to a maximum of 1700 mm The table top overhang in the length on the right and left may not exceed 100 mm The table base frame may be loaded by a maximum of 90 kg This is the combined total of the weight of the table top and the load on the table such as a computer screen and keyboard etc max 800 650 a o3 O uy To 735 Empfehlung 1200 1900 x max 100 einstellbar 1200 1700 max 100 Table base frame ELS3 18 4 5 1 CAUTION A Table base frame ELS3 SUSPA Step 1 Install table base frame Risk of damage Screws may not go into the housing deeper than 5 mm When screwing the motor housing to the frame make sure that the correct type of screw is used Use only the supplied screws Observe the maximum torque of 7 Nm of the B C screws SUSPA gt Fasten the transverse web inserts for lifting columns by using 2 C screws each to the longitudinal joints of the table top 4 5 2 Step 2 Fasten the table base frame to the table top gt Align the table base frame in the center on the bottom of the tabletop gt Fasten the mounted table base frame with the matching screws to the bottom of the table top 4 5 3 Step 3 Fasten foot sections to the lifting columns CAUTION Danger of damage to property through the use of the wrong screws The functionality of the lift is only guaranteed when the supplied screws are used
5. height 1220 mm Hub 650 o y Lifting capacity 50 kg per leg Length of motor cable 1200 mm Maximum static bending 150 Nm moment 24 V DC 3 3 Table base frame ELS3 16 SUSPA 443 Dimensions SUSPA COMPACT controller Output performance 280 VA Standby consumption lt 0 3 W 264 x 103 x 37 mm Input voltage 207 253 V 50 Hz Ambient temperature 0 30 C Relative air humidity 5 85 during operation _ Duty cycle max 10 1 min operation 9 min pause Electromagnetic In accordance with compatibility the EMC Directive and the valid EMC standards for industrial use 444 Dimensions SUSPA SMART controller Output performance 216 VA Standby consumption lt 0 3 W approx 305 g Input voltage 207 253 V 50 Hz Ambient temp 0 30 C Relative air humidity 5 85 during operation Duty cycle max 10 1 min operation 9 min pause Electromagnetic In accordance with compatibility the EMC Directive and the EMC standards for industrial use Table base frame ELS3 17 SUSPA 4 5 Setup and installation When assembling the table base frame ELS3 for office tables or desks with a custom table top into a finished table the following points must be observed see drawing below The table base frame is suitable for table top sizes of max 800 mm deep and 1200 mm 1900 mm in length The table base frame may be
6. risks You can mitigate the residual risks by observing and following the safety instructions and the intended use carefully and attentively as well as avoiding improper use Danger of death caused by dangerous voltage DANGER A Regularly check the electrical cabling of the table base frame Replace damaged cables Residual electrical energy remains in lines controller and motor after the table base frame is shut down In order to install and repair the table base frame it must be disconnected from the mains Table base frame ELS3 WARNING A WARNING A WARNING A CAUTION WARNING A 3 3 SUSPA Danger of stumbling Excess cables and wires as well as edges can cause a risk of stumbling Avoid having loose excess cables laying around If necessary use cable holders binders Risk of injury caused by improper or unauthorized modifications There are risks posed by making unauthorized modifications to the table base frame and using spare parts manufactured by third parties Use only original spare and wear parts supplied by the manufacturer Do not modify install additions or reconstruct the table base frame Danger of injury and damage to property due to incorrect operation Read the Chapter Operation and follow the safety instructions given there Use the table base frame only in compliance with the specifications in Chapter Operating conditions Non compliance with the operating
7. SUSPA GmbH apply These can be accessed online at www suspa com under Downloads General Terms and Conditions Liability and warranty claims in the case of damage to persons or objects are excluded if they can be attributed to one or more of the following causes m Improper use of the table base frame m Incorrect installation and commissioning of the table base frame m Disregarding the information in the operating instructions m Unauthorized modifications to the table base frame m Inadequate maintenance and repair work m Disasters caused by foreign objects or force majeure Target audience of the operating instructions The operating instructions are intended for the operator of the electrically adjustable table base frame Objectives of the operating instructions These operating instructions serve as support and contain all necessary instructions that must be observed and followed for general safety transport installation and use These operating instructions with all the safety information must m be followed read and understood by all persons working on the machine this is especially true of the safety instructions m be accessible to every one of the above mentioned target groups m be consulted even if the slightest doubt arises safety Objectives m Avoid accidents m Increase lifetime and reliability of the table base frame 3 1 DANGER A 3 2 3 2 1 DANGER A DANGER A Table base fr
8. SUSPA SUSPA GmbH Electrically adjustable table base frame Type ELS3 Read the operating instructions prior to the first commissioning Follow the safety instructions Please retain for future use Get the current operating instructions at www suspa com uk suspa service0 downloads user manuals July 2014 These operating instructions are a component of the technical documentation of the table base frame in accordance with the EU Machinery Directive These operating instructions correspond to the Guideline 2006 42 EC of the European Parliament and the Council for Adjustment of Legal and Administrative Regulations of Member States for Machinery Machinery Directive Appendix I Point 1 7 4 CE These operating instructions are addressed to the plant manager who must pass them on to the personnel responsible for installation connection use and maintenance of the table base frame The plant manager must ensure that the information contained in these operating instructions and in the accompanying documents has been read and understood The operating instructions must be stored in a place that is known to the personnel and easily accessible to employees and must be consulted even if the slightest doubt arises SUSPA GmbH is not liable for damage to people animals or objects or to the table base frame itself arising from the improper unauthorized use or through disregard or insufficient consideration of the safety criteria cont
9. USPA GmbH assumes no liability for damage resulting from such improper use Intended use also includes m Following all instructions in the operating instructions m Following all safety instructions Improper use m Using the table base frame and its electrical equipment contrary to its intended use m Using the table base frame outside or in damp rooms m Loading the table base frame with a load greater than 90 kg m Loading the table base frame with loads that are not centered m Using the table base frame for pulling on or from objects m Operating the table base frame beyond the physical operating limits as described in the Chapter Commissioning Operation m Operating the table base frame contrary to the specifications provided in the installation instructions regarding safety information installation operation and malfunctions m Operating the table base frame when there are obvious problems m Carrying out repair cleaning and maintenance work without first switching off the table base frame Risk of injury or damage caused by improper use or modifications Danger exists due to unauthorized modifications to or unauthorized use of the table base frame Only use original spare parts from the manufacturer Do not misuse and do not make modifications Table base frame ELS3 7 2 2 2 3 Table base frame ELS3 SUSPA General Instructions Warranty and Liability In principle the General Terms of Sale and Delivery of
10. ained in these operating instructions or through alteration of the table base frame or use of unsuitable spare parts At delivery SUSPA GmbH will replace or repair defective products covered by the warranty however beyond that SUSPA GmbH assumes no liability The copyright for these operating instructions is held solely by SUSPA SUSPA GmbH Muhlweg 33 90518 Altdorf GERMANY www suspa com or its legal successor Reproduction or circulation of these operating instructions to third parties only by express written permission of copyright holder This also applies if only excerpts of the operating instructions are copied or circulated These same conditions apply to the disclosure of the operating instructions in digital format Status July 2014 2 Table base frame ELS3 Archiving SUSPA gt Always keep the operating instructions ready at hand gt tis important to read the operating instructions before installation Symbols and signal words The following symbols and signal words are used in this documentation The combination of a pictogram and a signal word classifies the respective safety information The symbol can vary depending on the type of danger DANGER WARNING CAUTION CAUTION IMPORTANT When this signal word is used the consequence is death or severe physical injuries if the corresponding precautionary measures are not adopted or followed When this signal word is used personal injury or damage to p
11. ame ELS3 SUSPA General safety instructions Scope Danger to life risk of physical injury or damage to property There are dangers associated with disregarding or ignoring the operating instructions and the safety information contained therein Read the operating instructions carefully before operating the ELS3 table base frame for the first time Observe and follow the general safety instructions Follow the special safety instructions in the Chapter Design and installation The ELS3 table base frame has been constructed according to state of the art technology and recognized safety regulations In order to prevent danger to life and limb of the user third parties or to the table base frame use the ELS3 only for its intended purpose and in perfect condition with regard to safety Bodily injuries and or property damages resulting from non compliance with the instructions provided in the operating instructions are the responsibility of the company operating the table base frame Rectify any faults that may impair the safety of operation Observe and follow all safety instructions and hazard warnings Keep all safety and hazard warnings in proper legible condition at all times This device can be used by children from 8 years and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge when they have been given supervision or instruction concerning the safe use of the device and understand th
12. e cable Do not place heavy objects on the cable Do not pull on the cable Pull the mains plug to disconnect the table base frame from the power supply Immediately disconnect the controller from the power supply at any sign of cable breakage Please contact your specialist dealer DANGER Mortal danger when making modifications A There is a danger of electric shock when touching live parts inside the units Do not open the unit under any circumstances Only qualified personnel such as your specialist dealer may repair the unit 3 2 2 2 Dangers from mechanical energy WARNING A Danger of crushing injury or damage The movements of the lifting columns can cause injury If there are people or objects within the effective operating range of the table base frame there is a danger of crushing or of damage to objects The legs of the lifting columns are not fitted with pinch or crushing protection Do not reach into the effective range of the lifting columns during operation Make sure that there are no people animals or objects in the entire travel path of the lifting columns If the installed table construction is not stable there is a danger to objects due to unforeseen bending of components CAUTION Do not exceed the specified load capacity of the table base frame See Chapter Technical data 3 2 3 Residual risks Despite all the precautions that have been taken there may be unapparent residual
13. e resulting risks Children may not play with the unit The unit may not be cleaned and serviced by children lf there are any problems with the ELS3 table base frame immediately disconnect the controller from the power supply and contact your dealer Dangers Dangers posed by electrical energy Danger by improperly connected power cable An improperly connected power cable can cause a fire or an electric shock Operate the controller only at the mains voltage indicated on the nameplate Do not use a power source with high voltage or DC voltage Carefully check the power source Make sure that the mains cable is always connected correctly Danger by electric current You can get an electric shock when pulling on the mains cable Hold the plug firmly when unplugging the cable SUSPA DANGER Danger due to moisture and water A Moisture and water in the vicinity of the controller or the mains cable may cause an electric shock or a malfunction Do not touch or grip the mains plug with wet hands Do not allow moisture and water to reach the controller or power cables DANGER A Mortal danger through cable breakage or damage to the cable In case of cable breakage or damage to the cable there are dangers to life and limb or property damage caused by electric shock Never operate the table base frame with a damaged mains cable Only use the supplied mains cable Do not pull the cable across sharp edges Do not kink th
14. he table base frame Machine identification Electrically adjustable table base frame Type identification ELS3 Year of construction 2013 Designated use The electrically adjustable table base frame is used to raise a countertop for seating or standing workstations in the office the delivered version is compliant with Directive 2006 42 EC of the European Parliament and of the Council dated 17 May 2006 on machinery and conforms with the following harmonized standards and normative documents to which this declaration refers Applicable EC Directives EC Machinery Directive 2006 42 EC EC Electromagnetic Compatibility Directive 2004 108 EC Applied harmonized standards e DIN EN 527 1 2011 08 Office furniture Work tables and desks Part 1 Dimensions e DIN EN 527 2 2002 Office furniture Work tables and desks Part 2 Mechanical safety requirements e DIN EN 527 3 2003 06 Office furniture Work tables and desks Part 3 Test methods e DIN EN 61000 3 2 3 3 6 2 6 3 Electromagnetic Compatibility EMC e DINENISO 12100 2011 Safety of machinery Risk assessment and risk reduction e DIN EN 60335 1 2012 Safety of electrical appliances for household and similar purposes partially applied We hereby assure that the certification procedure is performed in accordance with the Machinery Directive 2006 42 EC and that the requirements of the standard DIN EN ISO IEC 17050 1 Conformity assessment Supplier s declaration
15. hin the effective operating range of the table base frame there is a danger of crushing or of damage to objects The legs of the lifting columns are not fitted with pinch or crushing protection Do not reach into the effective range of the lifting columns during operation Make sure that there are no people animals or objects in the entire travel path of the lifting columns 5 2 Operating 5 2 1 HSM OD 2 LD up down manual switch The HSM OD 2 LD up down manual switch is a simple manual switch with operating buttons to move the lifting columns up or down Up Moves the table up Down Moves the table down 5 2 2 Perform a reset gt Connect the power cable with the mains supply gt Press the down switch on the manual switch until approx 5 20 seconds the lifting columns have moved down to the lowest position followed by an upward movement of approx 2 3 mm CAUTION Perform a reset after every disassembly or exchange of the lifting columns and or controller Table base frame ELS3 24 6 1 6 2 6 3 Table base frame ELS3 SUSPA Decommissioning Follow safety chapter Observe and follow the Chapter General safety instructions from page 9 Switch off adjustment function gt Disconnect the power cable from the mains voltage Storing the table base frame The storage area should be cool and dry in order to prevent corrosion on the individual parts of the table base frame The
16. ine and in the operating instructions The special safety symbols or icons are used at appropriate places within the text in these operating instructions Warning signs Warning Danger zone Warning Hazardous electrical voltage A Warning Risk of hand injuries A Warning Trip hazard Mandatory signs Observe information provided Observe additional information Table base frame ELS3 Table of Contents 1 Identification 1 1 1 2 2 General Instructions 2 1 2 2 2 3 3 General safety instructions 3 1 3 2 3 2 1 3 2 2 3 2 3 3 3 4 installation 4 1 4 2 4 3 4 4 44 1 442 443 444 4 5 4 5 1 4 9 2 4 9 3 4 9 4 4 5 5 4 5 6 Table base frame ELS3 Designated use Improper use Warranty and Liability Target audience of the operating instructions Objectives of the operating instructions Scope Dangers Dangers posed by electrical energy Dangers from mechanical energy Residual risks Additional information Scope of supply View after assembly Operating conditions Dimensions and technical data Lifting column ELS3 BTU Lifting column ELS3 BTD Dimensions SUSPA COMPACT controller Dimensions SUSPA SMART controller Setup and installation Step 1 Install table base frame Step 2 Fasten the table base frame to the table top Step 3 Fasten foot sections to the lifting columns Step 4 Fasten controller to the table top Step 5 Fasten manual switch to table top Step 6 Connect
17. ions with controller 10 10 11 PE E E E N E E 11 12 14 14 15 15 16 17 17 18 19 20 20 21 21 21 95 Commissioning op ration ac tec este cece sten sce csc escort os cnc eaeeec diinon dadina sunie indiai 5 1 Commissioning 5 2 Operating 9 2 1 HSM OD 2 LD up down manual switch 0 2 2 Perform a reset 0 DS COMMIS SIO MING sta ene tersanriansene tasepotesensaiinudanrodes tannins totsatusihaniaebecaseistuastavniunaciervanndixsavnaits 6 1 Switch off adjustment function 6 2 Storing the table base frame 6 3 Disposal of table base frame 7 Spare parts Original EC Declaration of Conformity c cc csssssesesessessessessesesseesessessessessesaeseeseesensessesaesassaesessessessesseneeaseagss Table base frame ELS3 24 24 24 24 25 25 25 25 1 1 1 2 CAUTION A SUSPA Identification Electrical adjustable table base frame ELS3 SUSPA GmbH Telephone 49 91 87 9 30 0 Muhlweg 33 Fax 49 91 87 9 30 229 90518 Altdorf E mail info de suspa com GERMANY Website www suspa com Designated use The electrically adjustable table base frame is used to raise a countertop for seated or standing workstations in the office The lifting columns of the table base frame are designed for load that applies pressure Other use of the electrically adjustable table base frame or use beyond its intended purpose is considered non intended and thus improper In this case the safety may be impaired or compromised S
18. ntification 4 1 Scope of supply Table base frame ELS3 Check that the supplied and delivered lifting column system is complete These operating instructions apply for the following types m Electrical lifting column system ELS3 BTU slender tube at bottom or m Electrical lifting column system ELS3 BTD slender tube at top Lifting column ELS3 BTU square Part No 004 10161 Quantity 2 Delivered with retracted leg SUSPA COMPACT controller for ELS3 BTU Quantity 1 SUSPA SMART controller for ELS3 BTU Quantity 1 Lifting column ELS3 BTD square Part No 004 10162 Quantity 2 Delivered with retracted leg SUSPA COMPACT controller for ELS3 BTD Quantity 1 SUSPA SMART controller for ELS3 BTD Quantity 1 Manual switch Manual switch up down HSM up down HSM OD 2 LD OD 2 LD Part No Part No 098 10010 098 10010 Quantity 1 Quantity 1 Power cable EU Power cable EU shielded shielded Part No Part No 098 10011 098 10011 Quantity 1 Quantity 1 The following table base frame is designed for assembly with the electric lifting column system ELS3 BTU or the electric lifting column system ELS3 BTD Table base frame Frame Longitudinal table top for 2 leg system connection ELS3 Quantity 2 Part No 004 10165 Frame Transverse web insert for lifting columns Quantity 2 Foot section for lifting columns aa Quantity 2 ee ere Scre
19. of conformity Part 1 General requirements were complied with in the issuance of this declaration This declaration will lose its validity if any modifications are made to the machine without consultation with us Any unauthorized modifications in this sense excludes any liability on our part Altdorf den 4 44 L R a aS Vy P Ca lair Name Signature Management SUSPA GmbH Table base frame ELS3 26
20. or objects within the effective operating range of the table base frame there is a danger of crushing or of damage to objects The legs of the lifting columns are not fitted with pinch or crushing protection Do not reach into the effective range of the lifting columns during operation Make sure that there are no people animals or objects in the entire travel path of the lifting columns Connect the motor cable of a lifting column with input M1 of the controller Connect the motor cable of the second lifting column with input M2 of the controller 22 SUSPA Connect the manual switch with the controller CAUTION Connect the power cable in a way to ensure sufficient cable length over the entire adjustment N N Connect the mains cable with the POWER input on the controller The controller may only be operated after installation gt Connect the power cable with the controller gt Atleast two people are needed to place the fully assembled table on its feet gt f necessary level the table using the adjustable feet gt Perform a reset see page 24 Table base frame ELS3 23 SUSPA Commissioning operation 5 1 Commissioning Follow the safety instructions in the Chapter Installation WARNING Danger of crushing injury to hands or damage A The movements of the lifting columns can cause injury lf there are people or objects wit
21. room temperature at the storage location must constantly be between 10 C and 30 C The air humidity of the storage space must not be greater than 60 gt Package the table base frame so that it is not damaged by external influences whilst in storage gt f necessary use cardboard boxes and other packaging material gt Secure the table base frame against accidental tilting and instability during storage Disposal of table base frame Dispose of the packaging material in accordance with current national regulations gt Due to the danger of possible environmental pollution have the table base frame disposed of by an approved specialized company Spare parts Use only spare parts from the manufacturer of the table base frame SUSPA GmbH gt For ordering spare parts contact the following address SUSPA GmbH Telephone 49 91 87 9 30 0 Muhlweg 33 Fax 49 91 87 9 30 229 90518 Altdorf E mail info de suspa com GERMANY Website www suspa com You need the material number and description to place an order Please refer to the Chapter Scope of supply for more information 25 SUSPA Original EC Declaration of Conformity C according to the EC Machinery Directive 2006 42 EC Annex Il Section 1 A We hereby declare under our sole responsibility SUSPA GmbH Telephone 49 91 87 9 30 0 Muhlweg 33 Fax 49 91 87 9 30 229 90518 Altdorf E mail info de suspa com GERMANY that the type of construction of t
22. roperty may result if the corresponding precautionary measures are not taken It can also constitute an injury accident or health risk When this signal word is used the consequence may be minor physical injuries if the corresponding precautionary measures are not adopted or followed When this signal word is used the consequence may be malfunctioning This signal word is only used if no damage to health can occur The signal word is without a symbol since the degree of danger is slight When this signal word is used it refers to simplification of operations or cross references This signal word is only used if no damage to health can occur The signal word is without a symbol since the degree of danger is slight Other symbols and tags Handling instructions Provides instructions for a specific action Note Important information for understanding the device or for optimized operations Table base frame ELS3 SUSPA i Structure of warnings DANGER The first line describes the type and source of the danger The second line describes the consequences if no measures are adopted to safeguard against the danger The last line describes measures to avoid the danger WARNING Risk of injury by failure to observe safety symbols Ignoring or not following the warnings provided on the machine and given in the installation instructions may lead to injuries and other dangers Pay attention to and follow the warnings on the mach
23. w A M8x16 Quantity 8 Screw B M6x15 Quantity 12 Table base frame ELS3 13 Adjustable feet a Quantity 4 Allen key wrench Quantity 1 screw C M6x10 Quantity 21 The table top and the requisite ee a a material are not included 4 2 View after assembly The electrically adjustable table base frame is used to raise a countertop for seating or standing workstations in the office 1 4 2 5 3 View from the bottom 1 Table leg 1 4 Manual switch 2 Table top 5 Table leg 2 3 Controller with mains connection 4 3 Operating conditions 15 C to 30 C 30 to 60 No heavy dirt or contamination caused by dust acids and corrosive gases Table base frame ELS3 14 SUSPA fe 4 4 Dimensions and technical data 4 4 1 Lifting column ELS3 BTU 202 mm lt _______ Es ps ee E s 4 e e Lifting column view from the top 1220 mm 570 mm 065 Dimensions Lifting column 60 65 70 mm Lift 650 mm Retracted height 570 mm Extended height 1220 mm B mn Tsw Hub 650 Lifting capacity 50 kg per leg o 60 Length of motor cable 1200 mm Maximum static bending 150 Nm moment 24 V DC 60 mm Table base frame ELS3 15 f 4 4 2 Lifting column ELS3 BTD 202 mm Lifting column view from the top o D 1220 mm 570 mm m oO oa Dimensions Lifting column 70 65 60 mm Lift 650 mm Retracted height 570 mm Extended