User Manual Wireless remote control
Contents
1. only with the according charger 2010 7 13 EDT EURODIMA wireless remote control 5 5 Automatic sender shutdown APO function The sender is equipped with an automatic sender shutdown APO function and shuts down automatically approx 15 min after the last command entry This function is for safety and prolongs the battery life To reactivate the sender after an automatic shutdown you have to push the start button responsibility to turn off the sender with the STOP button if it is not needed anymore 4 The automatic sender shutdown does not release the user from the 6 BATTERY AND BATTERY CHARGER 6 1 NiMH battery The capacity of the battery depends on its age and the surrounding temperature Older batteries lose their capacity by and by Temperatures below 0 C and above 40 C make the capacity decrease quicker gt Charge the battery completely before first use and or after storage for longer than 6 months Consider that the battery reaches its full capacity only after 3 to 5 charging cycles charge and discharge completely Charge the battery only with the associated charger Charge the battery at a surrounding temperature of 0 to 40 C Charge the battery only if the status LED in the sender flashes red and an acoustic signal sounds Charge the battery completely before it is stored for a long period Otherwise it can lead to a total discharge Store the battery at room temperature Protect the battery fro
2. _EDT EURODIMA DIAMOND TECHNOLOGIES User Manual Wireless remote control SH EDT EURODIMA GMBH Diamond Technologies Plant Germany Lagerstrasse 6 Oberheinrieter StraBe 30 32 A 5071 Wals Salzburg D 74199 Unterheinriet Tel 43 0 662 42 42 48 Tel 49 0 7130 40095 0 Fax 43 0 662 42 42 48 20 Fax 49 0 7130 40095 20 e Mail office eurodima com e Mail office eurodima com www eurodima com www eurodima com EDT EURODIMA wireless remote control Contents 1 Eet 3 2 SALOU eer eege eeler deer ee lee 4 2 1 IUnfendediusez e 202er 4 2 2 Safety measures at installation and operaion nn 4 3 Te hnical E 5 4 Dimensions 2 ae ee 6 5 Olele E 6 5 1 Eelere ee E EES 6 52 MOG ser Rene 7 e EOI EEIE e a ee T T 7 e Se NEI e Ee Sender serrr a ng es 7 5 5 Automatic sender shutdown APO Tunchon nn 8 6 Battery and battery charger ccccccsssssseeeeeeeeeeeeeeeeeeeeeeeeeeeesenseeeeeeeeeeeeeseesseeeneeeeeeeeesensees 8 6 1 NIMH Re EE 8 Bee e 8 6 3 QA108600 QD108300 QD308300 with EG type approval 9 7 ABEE ee EE 10 Tet EN EE ee Ed 10 7 2 Frequency SWIN EE 10 7 3 EDT EURQDIMA Men E 11 7 4 Address switch via coded olug 11 7 5 Sender upcoding ee ee a preteen EHE Reedereien 12 8 Service and maintenance uunssssnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnen 12 9 Trouble sho ling aint ett iach he eee Aan 13 10 Liablility and Warranty E 13 2010 2 13 EDT EU
3. your detailed address and your telephone number so that you can be reached in case of questions gt To avoid transport damages please use the reusable form package that you received at the first delivery of the system or pad the system well Deliver it free to your dealer or to this address EDT EURODIMA GmbH Lagerstrasse 6 A 5071 Wals Salzburg gt If you want to bring a defect system yourself please call for an appointment 2010 12 13 EDT EURODIMA wireless remote control 9 TROUBLE SHOOTING Please check the functions first with cabin or cable control Problem Possible reason Measures No sender reaction when PNo voltage gt Check battery contacts for damage or dirt starting up gt Put charged battery into battery slot gt Charge battery fully Low voltage alert already Battery contacts damaged gt Check battery contacts for damage or dirt after short operation time or dirty gt Charge battery fully gt Battery not charged gt Check if the charging processes correctly gt Battery defect gt Check sender function with a fully charged or a replacement battery The status LED in the gt Receiver has no voltage gt Check connection cable to receiver sender flashes green gt No remote connection gt Check functions via LEDs to control lamps but no commands are gt Command crane on was of the receiver executed not given Some commands are not gt Receiver defect gt Check the connection cable
4. RODIMA wireless remote control 1 PREFACE This manual is for the user and the service personnel of that device It is not an alternative for the actual instruction We recommend an instruction by a qualified employee of EDT EURODIMA or by a sales partner that we have authorised All persons involved in start up service maintenance and or repair of this device must have fully read and understood that manual For any questions please get back to the producer or the authorised sales partner Please adhere to our safety measures and descriptions which are highlighted in this text by that sign A The wireless remote control has safety measures but nevertheless operation errors or misuse can lead to dangers Non observance can lead to danger for life of user or third parties damages at this device or other devices A damages at buildings decreasing the efficiency of the sawing system 2010 3 13 EDT EURODIMA wireless remote control 2 SAFETY Read this user manual attentively bevor you start working This is especially important for first installation start up and maintenance of the remote system The user manual is part of the remote control system and must be readily available for users at all times In the user manual the word machine is used for the different applications of the remote system 2 1 Intended use gt The remote control system is made for control of machines and for data transfer Al
5. e so called dead man s constraint Release all control elements so that they get back into 0 position and push the start button Only then the machine will react to remote orders again This prevents the machine from uncontrolled movements after connection disruptions 5 3 Turn on sender Steps 3 and 4 must be done within 4 seconds 1 Put a charged battery into the battery compartment 2 Tear the STOP button 3 Press the start button shortly and release it If the button is pressed for more than half a second the sender is turned off 4 Press the start buttom once again until the status LED flashes green Release the button Now the sender is ready for operation 5 According to the application you have to press the start button once again bevor commands can be made The sender turns off if gt the start button is pressed longer than half a second see above point 3 gt the start up process step 3 and 4 take longer than 4 seconds gt another button is pressed during the start up process Then you have to do the steps 3 and 4 or 3 to 5 again Before starting work always use the acustic alarm signal You alert your colleagues that they have to anticipate machine movements 5 4 Turn off sender Press the STOP button If the status LED flashes red in the sender an acoustic signal sounds and or the sender vibrates you have to change the battery Otherwise the sender turns off within minutes Recharge the battery
6. hen working without remote control during breaks or after end of work Always secure the remote control against use by unauthorised person e g by shutting away In case of emergency or during incidents turn off the remote control immediately by pressing the STOP button Only use the remote control in technically perfect condition Incidents or defects that affect safety must be removed by specialists that are trained and authorised by EDT EURODIMA before being used again Be aware that the movement directions of the control elements may seemingly change according to place and perspective to the machine This is especially valid for rotary cranes if your place is changed form inside the turning circle to its outside The user must acquaint himself with the sense markings at the machine prior to starting the machine Let repairs may only be done by specialists that are trained and authorised by EDT EURODIMA Only original parts and accessories e g batteries may be used as appliance safety may not be guaranteed and our guarantee will not apply anymore Work cautiously with the remote control and acquaint yourself with its functions especially if you it is the first time that you work with it or if you do is infrequently Prior to every start check the STOP button function If you press the STOP button when sender is on the status LED in the sender must turn out If it does not turn out stop the remote system immediately Remove the batte
7. m short circuit and always use the provided protection cap for storage Vv VV WV VV At proper handling more than 500 load cycles can be reached 6 2 Charger According to customer needs AC or DC chargers are available Please consider the following Only charge the batteries that are indicated on the type plate Do not use the charger in explosive areas Use the charger only with the voltage that is indicated on the bottom side Use the charger only in cars or in closed rooms Use the charger only within the indicated temperatures Protect the charger from heating dust and humidity Do not cover the charger during use Take away the charger from power if it is not used Stop use of the charger immediately if there is an error at the device or the cable Do not make technical changes at the charger or the cable Repairs may only be done by a specialist VVVVVVVVVV V 2010 8 13 EDT EURODIMA wireless remote control The current status of operation is shown via three LEDs LED green Illuminated if battery is fully charged LED orange Illuminated if battery is being charged LED red Illuminated if battery is defect or totally discharged is illuminated for a few seconds before the charging starts orange LED illumnated A If a battery that is totally discharged is put into the charger the red LED 6 3 QA108600 QD108300 QD308300 with EG type approval The charger is delivered with a connection cable with ap
8. or example self regulating doors can be opened and closed by different senders During longer breaks turn off the sender by pressing STOP The function sender upcoding does als save power of the battery The option sender upcoding does not release the user from the responsibility to turn off the sender with the STOP button if it is not needed anymore 8 SERVICE AND MAINTENANCE We recommend to have your remote control checked once per year by EDT EURODIMA or an authorised dealer The system is widely maintenance free However please consider the following gt Constantly check the functionality of the STOP button Sediments at the switch can affect mechanism and function gt Check the bellows rubber seals of the elements for their leak tightness Defect bellows or rubber seals must be changed immediately as humidity and dirt affect the functions gt Never clean the sender with a pressure washer or with sharp or pointed devices gt The sender batteries must be charged and discharged regularly In case of defect A Never work with a defect remote control system gt Never try to interfere into the electronics of a remote control system We would have to reject guarantee claims o Send the defect device immediately to your dealer or the producer They are well aquainted with the system and dispose of the necessary OEM parts o Always send in sender and receiver and add a detailed error description o Do not forget to indicate
9. propriate plug Charge battery 1 Connect the charger to current supply via the connection cable 2 Put the battery into the charging shaft Charging starts automatically Technical data 100 240 V AC QA108600 Supply voltage 10 30 V DC QD108300 QD308300 lt 5 Charging ime nn approx 3hous s lt tS Workingtemperature 10 400 i Casing material Plastes OO28 6 6 6 6 7 7 7T T ti i i aO S S C S Protection class o o 2010 9 13 EDT EURODIMA wireless remote control 7 OPTIONS Availability of the following options depends on model and configuration of your remote control system 7 1 Safety features O 3 The safety features allow a fast automatic shutdown of the remote controlling in specific ei emergency situations Possible dangers through unintended machine activations are avoided O shock off can trigger an automatic shutdown of the control when a strike is put on the sender e g if the sender is hit by a hard device and loses control S roll detect can detect rolling down of the sender and trigger quick shutdown zero g can detect falling or casting of the sender and trigger a shutdown of the sender O within seconds 4 T ES inclination switch can trigger an automatic shutdown if the sender exceeds a certain time in with the inclination angle of 130 to 170 and or lies with front side down must press the start button un
10. replacement sender without any problems On the masterkey all system dependent data such as frequency and system address are placed This information are transmitted when putting the key into the replacement sender The data transfer only works for senders that are equipped with these options Otherwise the masterkey is just to switch on and off the sender If a sender without preparation for the masterkey is operating with a masterkey the key has the same mechanical closure it continues to function on its internally programmed receiver see type plate 7 4 Address switch via coded plug The coded plug activates a preselected frequency and address coding that match the data of the related receiver If the coded plug is used in an identical replacement sender it gets the same data like the original sender and so it can access its receiver Change coded plug Turn union nut tothe jc Put coded plug in the bush of the left take off the ro replacement sender Turn union nut to coded plug tothe top lt the right and lock coded plug KS 2010 11 13 EDT EURODIMA wireless remote control gt Without coded plug operation is not possible gt If the coded plug is torn off during operation the sender turns off gt The coded plug has the serial number of the related receiver 7 5 Sender upcoding The sender is activated by commands only and turns off automatically 7 seconds after entry of the last command So f
11. ry and the iLOG from the sender and call a service technician 4 13 wireless remote control 3 TECHNICAL DATA 2010 EDT EURODIMA 334 338 MHz 400 475 MHz1 865 870 MHz 902 928 MHz DECT 1880 1900 MHz 1 not all frequency ranges are available 12 5 20 25 50 250 kHz DECT 1 728 MHz TC TX 641 lt 10 mW TC 680 690 lt 10 mW TC 681 691 lt 5 mW TX 681 691 lt 5 mW DECT nominal 10 mW 5 13 EDT EURODIMA wireless remote control 4 DIMENSIONS 216 mm 8 50 112 mm 4 41 a SO a an 202 mm 7 95 88 mm 3 46 5 OPERATION 5 1 Display _ VT EURODIMA d d S St rung S Motor is Uberlast gt dl 3 Motor Ei y otor Ein p 1 4 way push button switch ft cut in left l cut in right lt feed left gt feed right 2 Error 3 Motor overload 4 Motor on 5 Potentiometer for revolution setting feed and cut in 6 Motor on 7 Remote control on off 2010 6 13 EDT EURODIMA wireless remote control 5 2 iLOG The sender is equipped with the electronic key EDT EURODIMA iLOG The iLOG contains all data that are needed for the sender operation Without iLOG operation is not possible According to the model the iLOG can be used for replacement senders that are identical in construction When turning on or interrupting the remote connection e g at a connection break or when going over coverage the remote system reacts with th
12. the type plate in the battery place of the sender it is equipped with AFS automatic frequency selection When starting the sender AFS checks if the last used frequency channel is available If it is used the system finds automatically an available frequency channel and saves it If the currently used frequency channel is taken by another frequency system you have to turn off and on the sender again so that AFS can change to an available frequency channel The option AFS also includes the function manual frequency forwarding For an optimal performance of AFS all other remote control systems in direct surrounding e g the construction site should be turned on before starting the remote control for the first time So AFS can detect automatically which remote channels are taken by other systems and choose an appropriate available channel for the own system Furthermore when starting the control for the first time the user should pay attention to a realistic distance to the receiver and machine 7 2 5 EDT EURODIMA AFM If AFM is indicated on the type plate in the battery place of the sender it is equipped with AFM automatic frequency management AFM detects continually any available frequency channels If the currently used frequency channel is taken by another system AFM changes automatically to an available frequency channel 7 3 EDT EURODIMA masterkey This option allows the user to exchange a defect sender against a
13. til the status LED flashes green Then the sender is ready for use again Ce If the sender was switched of with shock off roll detect zero g orr inclination switch you V a A The safety features do not release the user from the responsibility to turn off the sender with the STOP button if it is not needed anymore 7 2 Frequency switch 7 2 1 Fixed frequency If a frequency is indicated in the battery place of the sender e g 433 500 MHz the sender is equipped with a fixed frequency If a change of frequency should be necessary because the channel is taken by another user please contact your service department 7 2 2 Frequency switch via scanner Sender and receiver are equipped with four frequencies If a frequency channel is used you can switch to another at the sender s rotary switch The scanner in the receiver follows the sender automatically to the new frequency within a second 7 2 3 Manual frequency forwarding If the type plate in the sender s battery place has the indication man the sender is equipped with the function manual frequency forwarding With this function you can change the frequency channal during remote control operation Press the start button until an acoustic signal sounds Then release the button If all available frequencies should be taken please contact your service department 2010 10 13 EDT EURODIMA wireless remote control 7 2 4 EDT EURODIMA AFS If AFS is indicated on
14. to the executed P Connection line to machine receiver for firm seatening is interrupted If none of these measures lead to resolving the problem call your service technician your dealer or EDT EURODIMA 10 LIABLILITY AND WARRANTY Unauthorized modifications and changes to the machine as well as non observance of the operating instructions void the manufacturer s liability for resulting damage We only warrant error free operation for original replacement parts manufactured by EDT EURODIMA GMBH Any guarantees and warranty become void if machines or machine parts have been opened This warranty is valid on condition that the machine is used handled maintained and cleaned according to the operating instructions Claims under the warranty will be recognized up to 12 months from the date of purchase invoice date The warranty includes the repair or replacement of defective parts free of charge Parts subject to normal wear are excluded from this warranty EDT EURODIMA is not liable for direct indirect or consequential damage from defects loss or expenses in connection with or resulting from the unsuitability of the device for a specific purpose Implied assurances of use or suitability for a specific purpose are expressly excluded 2010 13 13
15. ways watch the according work safety and accident prevention regulations gt Reading the user manual and compliance with the comprised safety notes is also intended use gt The system may not be used in explosive areas or for control of machines for passenger transport if it is not accredited explicitely by the producer gt Changes at the system may only be done by specialised staff that has been trained and gt Vv VV VV MM 2010 authorised by EDT EURODIMA All changes must be documented in a record that is factory provided at the producer Safety measures of the system may not be changed removed or bypassed Especially changes in any part of the emergency stop system are forbidden Safety measures at installation and operation The electric connection according to the attached wiring plan may only be done by an electician The receiver may only be opened by trained personnel Inner parts may be under perilous voltage The supply voltage of the machine must be turned off before opening the receiver Pay attention to the prohibition of persons in the danger area especially under loads cranes Choose a safe place for remote controlling where you see all the movements of the machine the load movements and the surrounding work conditions It is forbidden to put away a remote control with status on without supervision Always turn off the remote sender when it is not needed This is especially important if you change place w
Download Pdf Manuals
Related Search
Related Contents
Digi-Mux HS USER MANUAL - VTC Express manuel Aspen 3 2009.pub MANUAL DO USUÁRIO Photovac 2020 Pro Manual - Field Environmental Instruments, Inc. TX6A™ 10Gig™ カテゴリ 6A UTP 配線システム HE500TSW232 Manual Melissa 740-095 User's Manual La Crosse Technology TX62U-IT User's Manual Copyright © All rights reserved.