1. Figure 3 1 PIM_STATUS_IDLE Packet Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www it swa com Page 23 of 38 CHLAGE Wireless Access 3 3 3 PIM_STATUS_CHANGE similar to HereIsExtendedUserRecord byte Field Data Description 1 Start of Frame OAH 2 Address FFH 3 Type 31H 4 Length 05H 5 Bytel 6 Byte2 7 Data Byte3 8 Byte4 9 Byte5 10 11 Frame Check Sequence CRC or CHECKSUM Figure 3 2 PIM_STATUS_CHANGE Packet Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 24 of 38 CHLAGE Wireless Access byte bit function comments If FFH then PIM has nothing new to report and byte2 byte3 byte4 byte5 will all be 0 bytel WAPM address If 00H to FEH not AAH then byte2 byte3 byte4 contain the status for that WAPM 0 Reader tamper 1 the bytel WAPM has a reader tamper 1 Low Battery 1 the bytel WAPM has a low battery 2 Loss of RF Communications 1 the bytel WAPM has a loss of RF byte2 3 PIM Tamper 1 the polled PIM s door is open y 4 Cache Status 1 enabled 0 disabled 5 Motor Stall 1 the bytel WAPM s lock motor
2. byte bit function Comments bytel Door unlock time 1 255 seconds default 3 0 none 0 1 reverse Card format 2 Northern 1 l depends on PIM type 3 Northern 2 4 Northern 5 2 5 Northern 6 byte2 3 Trouble level not applicable on RS485 PIM 4 Door open level not applicable on RS485 PIM 5 Deny access l enable deny access option 0 disable deny access option 6 Re latch event 1 relatch on door open 0 relatch on door close 7 Relock method 1 relatch on door position change 0 timer only byte3 Heartbeat time low byte number of 15 second intervals low byte byte4 Heartbeat time high byte number of 15 second intervals high byte 0 WA WPR2 Reader type 1 iClass 0 all others default 0 1 Pre alarm enable 1 enable 0 disable 2 0 normal 3 1 Best WEXK bytes Motor type for IRL MIRL WA Ey ane moe 4 Schlage WA5600 WA993 amp Marks MIRL cyl 5 Schlage WA5200 5_ Latch Type for WISI 1 strike 0 relay 6 Request to exit mode 1 normal 0 inquiry fi Extended unlock 1 enabled 0 disabled 0 Retry times 1 15 default 5 3 byte 6 4 Door held open time 1 15 seconds 15 value 5 7 0 First Delay 0 15 100 mS resolution default 2 or 200 mS 3 byte 7 ri Subsequent Delay 0 15 100 mS resolution default 2 or 200 mS 7 byte 8 Cache memory bits per card 0 255 0 cache disabled default 0 0 reserved 1 reserved 2 reserved 3 reserved byte 9 i 4 Auto purge 1 disabled 0 enabled default 1 5 Failsafe mode 00 d
3. GET_WAPM_DATALOG page 15 NEXT_DATALOG page 28 send event details card data door alarms request to exit amp troubles GET_PREVIOUS_WAPM_DATALOG page 16 NEXT_DATALOG page 28 repeat sending event details in case of receiving error WAPM_LOCK_ CONTROL page 16 WAPM_STATUS page 22 control the lock strike state locked momentary unlock extended unlock WAPM_TIMED_UNLOCK page 17 WAPM_STATUS page 22 momentary unlock specifying the unlock time available in version 2 hardware only ABORT LINK page 22 WAPM_STATUS page 22 abort a current linking mode SET_LINK page 21 WAPM_STATUS page 22 initiate a linking mode SET_POLL page 21 PIM_STATUS_IDLE page 23 sets WAPM addresses to which the PIM will respond GET_OEM_CODE page 22 OEM_CODE page 28 to determine if the device is a PIM GET_WAPM PIM_ASSOCIATION page 21 WAPM PIM_ STATUS page 30 determine what PIM a WAPM is in GET_PIM_INFORMATION page 20 PIM_CONFIGURATION page 30 get PIM configuration information GET_WAPM_CONFIGURATION page 17 WAPM_CONFIGURATION page 31 to retrieve configuration data from a WAPM SET_WAPM_CONFIGURATION page 18 WAPM_STATUS page 22 to send configuration data toa WAPM Table 3 1 Commands and Their Responses 3 1 Communication Packet Format The protocol commands and responses both use the same communication
4. The Stop button can be used to abort the PIM 485 OTD RS link mode 2 4 PIM 485 OTD RS Alarms Each WAPM linked to a PIM 485 OTD RS can report five different types of alarms low battery reader tamper loss of RF communications lock motor stall and PIM tamper Refer to section 3 3 1 page 22 section 3 3 2 page 23 and section 3 4 4 page 34 for details on how these five alarms are reported using the RS485 protocol NOTE When a PIM tamper occurs and if polling is being done by WAPM then a PIM tamper alarm will be reported for each WAPM linked to the PIM that has the PIM tamper If polling by PIM then a PIM tamper will only be reported once when that PIM is polled 2 5 What Happens if the PIM 485 OTD RS Loses DC Power All of the configuration and linking information is stored in non volatile memory in the PIM 485 OTD RS Therefore if PIM 485 OTD RS DC power is lost or cycled upon restoring DC power the PIM will continue operation with the same configuration and linking information There is no need to re configure or re link Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 11 of 38 CHLAGE Wireless Access 2 6 Using the PIM 485 OTD RS Reset Switch The Reset Switch S3 is used if the PIM 485 OTD RS does not seem to be working properly Pressing the Reset Switch has the same effect as cycling DC power
5. byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 4DH 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com P N M053 027 D Table 3 5 GET_WAPM_DATALOG Command Packet Format Ingersoll Rand Security Technologies Wireless Access CHLAGE 3 2 1 4 GET_PREVIOUS_WAPM_DATALOG same as SendPreviousDatalog byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 6DH 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM Table 3 6 GET_PREVIOUS_WAPM_DATALOG Command Packet Format 3 2 1 5 WAPM_LOCK_CONTROL same as OutputControl Note The WAPM_LOCK_CONTROL command will only work with a battery operated Wireless Access Point Module WAPM WA52xx WA56xx WA993 WPR2 when it is sent in response to having received a card swipe data command byte Field Data Description 1 Start of Frame OAH WAPM Address 00H to FEh amp not AAH Type 4FH 2 3 4 Length 01H Data 1 timed unlock using the re latch time 2 extended unlock indefinite 3 re lock 4 turn on auxiliary relay WRI OUT only 5 turn off auxiliary relay WRI OUT only 6 reserved 7 red led on VIP only 8 red led off VIP only 9 green led on VIP on
6. 293 4257 fax www it swa com Page 25 of 38 CHLAGE Wireless Access 3 3 4 PIM _STATUS_CARDDATA similar to HereIsExtendedUserRecord byte Field Data Description 1 Start of Frame OAH Address FFH Type 31H Length 01H to 26H bytel byte2 byte3 byte4 OlaoOlNAT ND A AJIN byte5 See Table 3 24 below for a 10 Data byte6 detailed description of the byte1 11 byte7 byte38 formats 42 byte38 43 44 Frame Check Sequence CRC or CHECKSUM Table 3 23 PIM_STATUS_CARDDATE Packet Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 26 of 38 CHLAGE Wireless Access byte bit function comments if FFH then PIM has nothing new to report and byte2 byte3 byte4 byte5 will all be 0 bytel WAPM address if 00H to FEH not AAH then byte2 byte3 byte4 contain the status for that WAPM 0 Reader tamper 1 the bytel WAPM has a reader tamper 1 Low Battery 1 the bytel WAPM has a low battery 2 Loss of RF Communications 1 the bytel WAPM has a loss of RF byte2 3 PIM Tamper 1 the polled PIM s door is open y 4 Cache Status 1 enabled 0 disabled 5 Motor Stall 1 the bytel WAPM s lock motor
7. How to Set an RF Channel One of fifteen RF channels can be set using DIP switch SW7 on the PIM Table 2 5 shows how to set SW7 to select the desired RF channel Channel Switch 1 Switch2 Switch3 Switch 4 1 up up up Up 1 up up up down 2 up up down Up 3 up up down down 4 up down up Up 5 up down up down 6 up down down Up 7 up down down down 8 down up up Up 9 down up up down 10 down up down Up 11 down up down down 12 down down up Up 13 down down up down 14 down down down Up Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 10 of 38 CHLAGE Wireless Access 15 down down down down Table 2 5 DIP Switch Setting to Select the RF Channel NOTE The first two switch settings select Channel 1 2 3 2 Linking WAPM s using the Configuration amp Demonstration Tool CDT The Schlage Wireless Access Schlage Wireless Access Configuration amp Demonstration Tool CDT version 1 43 or higher can be used to link WAPM s to a PIM 485 OTD RS The PIM 485 OTD RS must be connected to the PC running the CDT using a serial connection either RS485 or RS232 NOTE When using an RS232 connection any RS485 connection must be disconnected for the CDT to operate properly Remember to re connect the RS 485 when done confi
8. 36 of 38 CHLAGE Wireless Access 5 FCC Compliance amp Warnings 5 1 FCC Compliance This device has been authorized by the FCC Rules and Industry Canada This device complies with the limits for a Class B digital device and a Class B intentional radiator pursuant to Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The Wireless Access System Component must be installed by qualified professionals or contractors in accordance with FCC part 15 203 Antenna Requirements Do not use any antenna other than the one provided with the unit 5 2 ACA Compliance The Australian version of the Panel Interface Module AUPIM TD2 AUPIM TD4 AUPIM 485 OTD or AUPIM EXP has been authorized by the Australian Communications Authority ACA 5 3 UL Compliance The Panel Interface Module PIM 485 OTD is listed under UL294 as an access control system accessory Access equipment manufactured and or sold by Schlage is not rated for or intended for use in life safety installations For UL installations use Schlage Power Supply model 593PI 12DC UL listed class 2 power supply For UL installations the Panel Interface Module enclosure PIM 485 OTD must be mounted in a secure area The Panel Interface Module s P
9. PIM 485 OTD RS plastic 16 indoor RS485 Optional remote indoor only ANT REM IN plastic n a indoor ee a omni directional antenna ANT REM I O plasie ia indoor Optional remote indoor outdoor outdoor omni directional antenna indoor Optional remote directional ANT REM I O 6DB plastic n a outdoor panel antenna 6 dB gain Table 1 2 PIM 485 OTD RS Sales Model Table Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com Page 7 of 38 P N M053 027 D CHLAGE Wireless Access 2 Installing the PIM 485 OTD RS 2 1 Configuring the PIM 485 OTD RS The Schlage Wireless Access Configuration amp Demonstration Tool CDT version 1 43 or higher must be used to configure each PIM 485 OTD RS to emulate the desired number and address of Recognition Systems Readers The PIM 485 OTD RS must be connected to the PC running the CDT using a serial connection either RS485 or RS232 NOTE When using an RS232 connection any RS485 connection must be disconnected for the CDT to operate properly Remember to re connect the RS 485 when done configuring Once the PIM 485 OTD RS is powered and connected to the PC and the CDT is running press and hold either the SA or SB switch on the PIM 485 OTD RS while pressing and releasing the Reset switch on the PIM 485 OTD RS Once the PIM 485 OTD RS LED s CR7 amp CR10 start to flash the
10. Packet Format Ingersoll Rand Security Technologies CHLAGE Wireless Access 3 2 2 4 GET_WAPM PIM_ASSOCIATION similar to EnterIdleMode2 byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 65H 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM Table 3 15 GET_WAPM PIM_ASSOCIATION Command Packet Format 3 2 2 5 SET POLL similar to EnrollUser Note When using the SET_POLL command to set the polling addresses only one PIM 485 OTD RS can be on the RS485 bus All other PIM 485 OTD RS s must be temporarily disconnected byte Field Data Description 1 Start of Frame OAH 2 PIM Address 00H to FEh amp not AAH 3 Type 49H 4 Length 02H 5 Da Low WAPM range 0 to FEH not EEH 6 High WAPM range 0 to FEH not EEH 7 8 Frame Check Sequence CRC or CHECKSUM Table 3 16 SET_POLL Command Packet Format 3 2 2 6 SET_LINK similar to EnterIdleMode byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 45H 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com P N M053 027 D Table 3 17 SET_LINK Command Packet Format Ingersoll Rand Security Technologies Page 21 of 38 Wireless
11. SA SB switch can be released This places the PIM 485 OTD RS in the CDT communication mode If the CDT is shut down and restarted the PIM 485 OTD RS must be reset as indicated above to return to the CDT communication mode 2 1 1 PIM 485 OTD RS Configuration Once the CDT shows that the PIM 485 OTD RS is connected the Addresses tab on the CDT s PIM panel is used to configure the PIM 485 OTD RS s emulation addresses There are four fields on the Addresses tab Unique Addr Lo Addr Hi amp PIM Addr The Unique field shows the PIM 485 OTD RS unique address and should never be changed without instructions from Schlage Technical Support The Addr Lo indicates the lowest WAPM address that the PIM 485 OTD RS will emulate and Addr Hi indicates the highest The PIM Addr indicates the address that this PIM will respond to when PIM polling is used Table 2 1 shows the allowable range of values for the Addr Lo Addr Hi amp PIM Addr fields on the CDT Addresses tab PIM Model Addr Lo Addr Hi PIM Addr PIM 485 OTD RS 0 254 0 254 0 254 address 255 FFH is reserved for the ACP address address 170 AAH is reserved for broadcast messages Table 2 1 CDT Addr Lo amp Addr Hi Fields Range of Values After setting the Addr Lo Addr Hi amp PIM Addr fields to the desired values click the Set button to send these values to the PIM 485 OTD RS Rule for setting PIM Addr For multiple PIM 485 OTD RS s on the same communi
12. datal byte12 byte13 bytel4 byte15 bytel6 data2 byte17 byte18 timestamp N am kem R en E a am E m A em E n E n E a E e e e Table 3 36 Request to Exit Activated Datalog 3 4 6 Door Open Too Long The Door Open too Long datalog is sent by the WAPM when the WAPM s door is held open too long after being unlocked byte field description bytel address address of WAPM generating datalog byte2 byte3 byte4 byte5 byte6 byte7 byte8 format byte9 byte10 bytell datal byte12 byte13 bytel4 byte15 bytel6 data2 bytel7 byte18 timestamp es an COLO LOlOlOsOlOlOsO R OoOlsolyolsol ol o Table 3 37 Door Open Too Long Datalog Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 35 of 38 CHLAGE Wireless Access 4 Contacting Schlage Wireless Access For questions regarding Schlage Wireless Access www ir swa com main 800 313 2962 630 876 5680 technical support 866 322 1237 fax 630 293 4257 Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page
13. each PIM 485 OTD RS will emulate NOTE This manual is to be used in addition to the PIM Installation Manual M053 001 xxx and the Wireless Access System Configuring and Operating Manual M053 007 xxx There are five steps to installing a PIM 485 OTD RS 1 Using the PIM Installation manual M053 001 xxx determine the optimum PIM 485 OTD RS mounting location and permanently mount the PIM 485 OTD RS in that location 2 Using the Access Control Panel s ACP Installation Procedure mount and install the ACP and connect it to the PC that will be running the Access Control Software Using this manual configure amp connect the PIM 485 OTD RS to the ACP 4 Using the ACP s User s Manual configure the software to work with the PIM 485 OTD RS U sing this manual link the PIM 485 OTD RS to all the WAPMs it will control section 2 3 page 10 Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 6 of 38 CHLAGE Wireless Access Table 1 1 and Table 1 2 show the PIM 485 OTD RS sales models and their major specifications Sales Models PIM 485 OTD RS Closed Enclosure Opened Enclosure internal c Antenna or optional remote Table 1 1 PIM 485 OTD RS Enclosure MAXIMUM ACCESS CONTROL PANEL MODEL ENCLOSURE NUMBER LOCATION INTERFACE DESCRIPTION OF WAPMs
14. set until that WAPM communicates with the PIM A subsequent SET WAPM CONFIGURATION command must not be sent until the Configuration Mode bit is cleared for all WAPMs linked to that PIM P N M053 027 D Table 3 24 PIM_STATUS_CARDDATA bytel byte38 Definitions Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www it swa com Page 27 of 38 CHLAGE Wireless Access 3 3 5 NEXT_DATALOG same as HereIsNextDatalog response byte Field Data Description 1 Start of Frame OAH 2 Address FFH 3 Type 38H 4 Length 12H 5 bytel 6 byte2 7 byte3 8 byte4 9 byte5 10 byte6 11 byte7 12 byte8 13 byte9 See section 3 4 below for a Data detailed description of the byte1 14 bytel0 byte18 formats 15 bytel1 16 byte12 17 byte13 18 byte14 19 bytel5 20 byte16 21 byte17 22 byte18 23 24 Frame Check Sequence CRC or CHECKSUM Table 3 25 NEXT_DATALOG Packet Format 3 3 6 OEM_CODE same as HereISOEM Code response byte Field Data Description 1 Start of Frame OAH 2 Address FFh 3 Type 4FH 4 Length 02H 5 57H ascii W 6 en 41H ascii A 7 8 Frame Check Sequence CRC or CHECKSUM P N M053 027 D Table 3 26 PIM OEM_CODE Pa
15. to the PIM 485 OTD RS Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 12 of 38 CHLAGE Wireless Access 3 Protocol Commands Responses amp Datalogs This section is intended for reference and to document how the PIM 485 OTD RS uses the Recognition Systems protocol It is not a detailed description of the protocol for protocol details please refer to the Recognition Systems Hand Geometry Unit Technical Manual version 2 0 70100 6006 A subset of the Recognition Systems Hand Geometry Unit Protocol commands responses and datalogs are implemented in the PIM 485 OTD RS The Recognition Systems protocol is a multi drop polling protocol where the ACP is the master and the PIM 485 OTD RS s are the slaves As master the ACP initiates all communications using addressed commands and then waits for a response from the addressed PIM 485 OTD RS The Recognition Systems protocol provides for polling by access point Standard Recognition Systems commands and responses have been implemented to allow for polling by WAPM In larger systems where there maybe be up to 254 WAPM s on a RS 485 bus polling by WAPM would result in a long round trip polling time In order to reduce the round trip polling time the ability to poll by PIM is included Modified Recognition Systems commands and responses have been implemented to poll
16. 7 52 Warnings ennir E E AEE E A EE EEEE R EESK 37 Gs Revision Hist rys ssscssrsssercorcssessssossssssssostssbesoses sees vaop on tsois kob evers sisses tisessa oss sinio o soporo S ornoek aS ob sss So EES Ea resosi 38 P N M053 027 D Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com Page 4 of 38 CHLAGE Wireless Access Wireless Access System WAS 1 1 Overview Every access control system that uses Wireless Access contains two different types of modules Figure 1 1 e at least one Wireless Panel Interface Module WPIM and e at least one Wireless Access Point Module WAPM Wireless Wireless Access Panel Access g Wired Wired Access Control Interface Point i i Communication Communication Point Panel Module Module WPIM WAPM Access Control Panel Location i Access Point Location Figure 1 1 Wireless Access System Block Diagram The WPIM is wired to the access control panel and ideally is installed very close to the access control panel The WPIMs installation location is determined by the location of the WAPMs with which it will communicate using RF The WAPM is installed at the access point where access will be controlled and or monitored Depending on the application and which WAPM is used some wiring at the access control point may be required Regardless of which WPIM or WAPM module is used t
17. 85 OTD RS to an AOP oe ee eceecesseeeceseeeeeseseeesecaeesecnaeseceaecaessecaeeaecnaeenesaesateaeeaeeetente 9 2 2 1 PIM 485 OTD RS using an Original PIM PCB ee eeseeesecseesecneeerceseseeeceaeeecsaecateaecaeestenaeeneeaeeneeaes 10 2 2 2 PIM 485 OTD RS using a RS485 PIM PCB configured for 2 wire communication cece 10 2 2 3 PIM 485 OTD RS using a RS485 PIM PCB configured for 4 wire communication e cece 10 2 3 Linking the PIM 485 OTD RS to WAPMS ssoneosoresienicosiemeien 10 2 3 1 Howto Setan RIF Channel vi 5 scc c2sicss eneinio soca iezesdiutiansdea ect sctuss den lesteceasas so causteststeas EO 10 2 3 2 Linking WAPM s using the Configuration amp Demonstration Tool CDT 11 24A PIMP485 OTD RS Alaris seoor dinine Chueh ces cotaeeas doapscentetaisees coup tuevaweas EA stasis csuetsascoasvies dls 11 2 5 What Happens if the PIM 485 OTD RS Loses DC Power esccescessessseeseeeseeeeeeeeeeseeeseeeeeeeeeeeeeneeeneensees 11 2 6 Using the PIM 485 OTD RS Reset Switch ccccccccecssessseeseeesceseeeseceeeceseceaeceaecaeecaeeeseeeeeeeeeeeeesereneeeneenaees 12 3 Protocol Commands Responses amp Datalogs essesessoeseesoesesoesoesessoesessoesesoessesossoeseesossesosssesoessesessosoesossesssse 13 3 1 Communication Packet T orma isernia AA A O E AA AAA E e 14 22 Command Foma o A A EAE EAE E EAEE NOAOA 15 3 2 1 Commands for Addressing WAPM S sccessssssesseesecteeeesecaeesceneesecnaeenesaecateaecaeseten
18. AAH 6 PIM address 00H to FEh amp not AAH 7 8 Frame Check Sequence CRC or CHECKSUM Table 3 30 WAPM PIM STATUS Packet Format 3 3 8 PIM_CONFIGURATION byte Field Data Description 1 Start of Frame OAH 2 Address FFh 3 Type 53H 4 Length 06H 5 Low byte of PIM RF address 6 High byte of PIM RF address 7 Type of PIM 8 aii Low WAPM range 0 to FEH not EEH 9 High WAPM range 0 to FEH not EEH 10 PIM RF Channel 11 12 Frame Check Sequence CRC or CHECKSUM 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www it swa com P N M053 027 D Table 3 31 PIM CONFIGURATION Packet Format Ingersoll Rand Security Technologies CHLAGE Wireless Access 3 3 9 WAPM_CONFIGURATION similar to HereIsUserRecord response byte Field Data Description 1 Start of Frame OAH 2 WAPM Address FFH 3 Type 32H 4 Length 10H 5 bytel 6 byte2 7 byte3 m WAPM 8 byte4 configuration 9 byte5 ia bi data structure ue see Table 3 11 page 19 above 11 byte7 12 byte8 Data 7 13 byte9 14 bytel0 0 15 bytel 1 0 16 bytel2 0 17 byte13 0 18 bytel4 0 19 bytel5 0 20 bytel6 0 21 22 Frame Check Sequence CRC or CHECKSUM Figure 3 3 WAPM_CONFIGURATION Packet Format 3 4 Datalog Formats This
19. Access CHLAGE 3 2 2 7 ABORT_LINK same as Abort byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 32H 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM Table 3 18 ABORT_LINK Command Packet Format 3 2 2 8 GET_OEM_CODE same as SendOEMCode byte Field Data Description 1 Start of Frame OAH 2 PIM Address 00H to FEh amp not AAH 3 Type 6FH 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM Table 3 19 SEND_OEM_CODE Command Packet Format 3 3 Response Format Responses are data packets sent from the PIM 485 OTD RS to the ACP 3 3 1 WAPM_STATUS similar to HereIsStatus response byte Field Data Description 1 Start of Frame OAH 2 Address FFh 3 Type 30H 4 Length 03H 5 Bytel 6 Data Byte2 7 Byte3 8 9 Frame Check Sequence CRC or CHECKSUM Table 3 20 WAPM_STATUS Packet Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com P N M053 027 D Page 22 of 38 CHLAGE Wireless Access byte bit function Comments 0 Reader tamper 1 the polled WAPM has a reader tamper 1 Low Battery 1 the polled WAPM has a low battery 2 Loss of RF Communicat
20. CHLAGE Wireless Access READ FIRST WHEN INSTALLING A PIM 485 OTD RS Addendum INSTALLING CONFIGURING amp OPERATING PANEL INTERFACE MODULE RS485 Recognition Systems Version PIM 485 OTD RS The most current version of this document is available for download at http www ir swa com iy Ingersoll Rand ecurity Technologies S P N M053 027 D CHLAGE Wireless Access Schlage Ingersoll Rand Security Technologies 245 W Roosevelt Road Building 7 Suite 48 West Chicago IL 60185 main 800 313 2962 630 876 5680 technical support 866 322 1237 fax 630 293 4257 web ir swa com Copyright 2003 2008 Ingersoll Rand all rights reserved No part of this document can be reproduced transmitted or transcribed in any form by electrical mechanical optical manual or otherwise without the prior written consent of Ingersoll Rand Ingersoll Rand reserves the right to alter or revise the content of this document as needed to support future product revisions without obligation to notify any persons of specific changes The use of trademarks trade names or other product identification is solely for reference purposes All other product brand names are trademarks or registered trademarks of their respective holders Ingersoll Rand believes the information in this document to be accurate and reliable Ingersoll Rand does not guarantee results from the use of this information Ingersoll Rand assumes no responsibility o
21. EM_CODE same as HereISOEM Code respomnse cccccescessseeseeeeceeeeseceaecseeceeecaeecaeeeseeeeeseneereas 28 3 3 7 WAPM PIM STATUS scsscestecsieucs oledaess ofsbeses ecaccunpdeuss olscavasobsbecel E A 30 3 3 8 PIM CONFIGURATION cccccesessesesseseeseseeseeecseesesecneaesecnesaesecneaesecaseaesecaeesesecaeeacecaeeseeecaesaeereneeeses 30 3 3 9 WAPM_ CONFIGURATION similar to HereIsUserRecord response eececeeesteeeeeeeeeeereeseenteees 31 3 4 i Datalos FOrmnats 3 32 22a ikea evel etetacst tenes Aas cehei ates este hat eeeaceeset reeset 31 3 4 1 Transaction Buffer Empty cccccecccesccesscesecesecseecaeecseeesecseeeeeeeseeeseeeseceaecaeceaecsaecaeecaeecaeseneeeneseneeerenas 32 3 4 2 Identity Verde 5c cess vsnc otstacestissencusbssanesgestedsteiecstasseuchlciaitsaesdatek eis asdstasseaceabetaetiaas eds ast aateeleess Sins 32 3 4 3 Door Forced Opetics csisic assvsteccisdicdiaiet e a EE pide asta dha dead ese sea 33 3 4 4 Tamper Activated asenin iesciizecc ceeds nnne i EE A EEE ER cds cuideacadecdaevadeas 34 3 4 5 Request to Exit Activated ssnicisriieanie ie E EES AEE R Rii 35 3 4 6 Door Open Too LOM es iniia necnnnian innn a a a a avvaeedsccdeyatsaveuceassbscvaevss 35 4 Contacting Schlage A E E E ET EEE EE A ES 36 5 FCC Compliance amp Warnings cssssccssscssssscssssssscscscscesecesccssccssessscssscssscsssscescssecesscsseessessocssscssscsssssosesees 37 Dil FOC Compliance sieisen i EREA N EEEE E ETE EEEE ER ES 3
22. IM 485 OTD maximum standby current at 12 VDC is 70mA 5 4 Warnings P N M053 027 D RF Exposure To comply with FCC RF exposure requirements for mobile transmitting devices this transmitter should only be used or installed at locations where there is normally at least a 20 cm separation between the antenna and all persons Do not co locate and operate in conjunction with any other antenna or transmitter Changes or modifications not expressly approved by Schlage could void the user s authority to operate the equipment Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com Page 37 of 38 CHLAGE Wireless Access 6 Revision History Version Date Changes X001 12 19 02 preliminary in house release for comments X001 1 12 20 02 added card conversion sections added single channel selection section 001 12 20 02 added HID to card conversion name released for publication 002 02 06 03 changed WA logo corrected OUTPUT _ CONTROL command section consistently used byte instead of data added checksum as frame check method changed some command response names for better correlation with Wireless Access terminology added PIM polling added commands POLL_WAPM_CHECKSUM POLL_PIM WAPM_TIMED_UNLOCK GET_OEM_CODE GET_WAPM_CONFIGURATION amp SET_WAPM_CONFIGURATION added responses OEM
23. Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 32 of 38 CHLAGE Wireless Access byte field description bytel address address of WAPM generating datalog byte2 byte3 byte4 byte5 byte6 byte7 byte8 format byte9 byte10 bytell datal byte12 Card data read at WAPM either Wiegand or byte 13 magnetic data first 80 bits format depends on bytel4 which card conversion is being used refer to byte15 section 2 1 2 page 9 above bytel6 data2 byte17 byte18 timestamp ClOlOlO sol ol o Table 3 33 Identity Verified Datalog 3 4 3 Door Forced Open The Door Forced Open datalog is sent when a door position switch has indicated that the door has been opened i e door position switch goes from low to high when was not shunted and it was locked byte field description bytel address address of WAPM generating datalog byte2 byte3 byte4 byte5 byte6 byte7 byte8 format ODH byte9 byte10 bytell datal byte12 byte13 bytel4 byte15 bytel6 data2 bytel7 byte18 timestamp SolOlsO ol o o COlOlOlOsOlol ol o o Table 3 34 Door Forced Open Datalog Ingersoll Rand Security Technologies 245 W Roosevelt Ro
24. URATION Command Packet Format 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www it swa com P N M053 027 D Ingersoll Rand Security Technologies Page 17 of 38 CHLAGE Wireless Access 3 2 1 8 SET_WAPM_CONFIGURATION similar to HereIsUserRecord NOTE The SET_WAPM_CONFIGURATION command must only be sent when the Configuration Mode bit in the WAPM_STATUS PIM_STATUS_CHANGE or PIM_STATUS_CARDDATA for all WAPMs linked to the PIM are reset 0 byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 37H 4 Length 10H 5 bytel 6 byte2 7 byte3 oh WAPM 8 byte4 i configuration 9 byte5 ii vine data structure e yt see Table 3 11 page 19 below 11 byte7 12 byte8 Data yte 13 byte9 14 byte10 0 15 bytel1 0 16 bytel2 0 17 byte13 0 18 bytel4 0 19 bytel5 0 20 bytel6 0 21 22 Frame Check Sequence CRC or CHECKSUM Table 3 10 SET_WPAM_CONFIGURATION Command Packet Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 18 of 38 CHLAGE Wireless Access
25. _CODE WAPM_CONFIGURATION PIM_STATUS_IDLE PIM_STATUS_CHANGE amp PIM_STATUS_CARDDATA 003 04 24 03 removed Datalog flag from PIM_STATUS_CHANGE amp PIM_STATUS_CARDDATA responses added Request to Exit Active WAPM Forced WAPM Open Too Long amp Tamper Active flags to PIM_STATUS_CHANGE amp PIM_STATUS_CARDDATA responses added commands POLL_PIM_CRC POLL_PIM_CHECKSUM SET_LINK SET_POLL GET_WAPM PIM_ASSOCIATION amp GET_PIM_INORMATION added responses WAPM PIM_STATUS amp PIM_CONFIGURATION 004 05 05 03 PIM Configuration packet changed PIM Address byte to PIM RF Channel byte corrected several figure table captions 005 05 18 04 updated block diagrams updated remote antenna models added PIM tamper reporting note noted that WAPM_TIMED_UNLOCK command is available in version 2 PIMs amp WAPMs deleted battery references in Warning section changed TOC to show 3 levels added note about card data bits transferred 01 24 05 Ir ized manual wl gt 09 29 05 Implemented SET POLL GET _WAPM_ CONFIGURATION amp SET _WAPM_ CONFIGURATION commands and WAPM_ CONFIGURATION response added WAPM configuration data structure changed PIM model number references to PIM 485 OTD RS re formatted table of contents to show 4 levels corrected FCC statement may not cause changed various nomenclature and contact info throughout manual added VIP OEM_CODE responses added VIP red led green led beeper con
26. ad Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 33 of 38 CHLAGE Wireless Access 3 4 4 Tamper Activated The Tamper Activated datalog is sent when a WAPM has detected one of five different types of trouble that need attention This datalog contains information identifying the exact cause of the trouble byte field description bytel address address of WAPM generating datalog byte2 0 byte3 0 betes timestamp f byte6 0 byte7 0 byte8 format OEH 0 Reader Tamper 1 Low Battery 2 Loss of RF Communication byte9 PIM Tamper 5 datal Motor Stall 6 7 bytel0 0 bytel 1 0 bytel2 0 bytel3 0 bytel4 0 bytel5 0 byte16 data2 0 byte17 0 byte18 0 Table 3 35 Tamper Activated Datalog Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 34 of 38 CHLAGE Wireless Access 3 4 5 Request to Exit Activated The Request to Exit Activated Verified datalog is sent when the WAPM s request to exit switch is activated i e closed goes from high to low byte field description bytel address address of WAPM generating datalog byte2 byte3 byte4 byte5 byte6 byte7 byte8 format byte9 byte10 bytell
27. aeeneeaecaeeeeeaeeataes 15 3 2 1 1 POLL WAPM_CRC same as SendStatusCRC sssessesesesesessseeeesseserssseesessesresseseeseeresseseeseeseese 15 3 2 1 2 POLL WAPM CHECKSUM same as SendStatusChecksum cessecseeseeeceeeeeeeeeeeeeeeeeees 15 3 2 1 3 GET _WAPM DATALOG same as SendDatalog 0 0 ceeceesesseeseceeeeeceeeeecaeeeessecaeeeeaesaeeneeneeeees 15 3 2 1 4 GET PREVIOUS WAPM DATALOG same as SendPreviousDatalog 0 0 0 eceseeeeseeeeeeeeneeeees 16 3 2 1 5 WAPM LOCK CONTROL same as OutputComnttrol 0 ee eeceeeeeseereeeeceeeeeceeeeceaeeeeeaesateneeneeeees 16 3 2 1 6 WAPM_ TIMED UNLOCK similar to DisplayCodedMessage essesecesceeeeeeeeeeseeneeneeneeeees 17 3 2 1 7 GET _WAPM_ CONFIGURATION similar to SendUserRecord 0 c ee eeeeeseeeceeeeeeseeeeeeeeseenees 17 Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 3 of 38 CHLAGE Wireless Access 3 2 1 8 SET WAPM CONFIGURATION similar to HereIsUserRecord ceceseeceeeceteereeseceeeeeeneeeees 18 3 2 2 Commands for Addressing PIM S cssssssccssessceseeecseeecesecaeesecneeseceaeenssaecateaecaeveeeeaeeneeaecaeeaeeaeeatenes 20 3 2 2 1 POLL PIM CRC similar to Calibrate eee ccesecseeeecneeeeceseeeeeecsseeeeesecaeseeeneeseceaeenesaesaeeeeeneeetes 20 3 2 2 2 POLL PIM CHECKSUM similar to SendExtendedUserRecord ceeecceseeeecet
28. bligation or liability for the information presented in this document Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 2 of 38 CHLAGE Wireless Access INSTALLATION amp OPERATING INSTRUCTIONS TABLE OF CONTENTS 1 Wireless Access System WAS scccccccccscsssscasecnssescosssesscussevasesssosesssassesecesseonseceseessosssarscesssnsnensesusacctscasecoascasooasoes 5 DoD QV GEIS Wie ses vcse seek A E A ck aes oe east eu Sate ees A dente vCal wand oes ete A erases Least 5 1 2 Panel Interface Module RS485 Recognition Systems PIM 485 OTD RS ceeecseeseeeeeereeseeeeeseceeeeeeneeeres 6 2 Installing the PIM 485 OTD RS sssscsssssssssssssssnsscsssssssssssenessssneesesssssescesssesosssssnessssnessesseessssnessessessesesssoes 8 21 Confi uring the PIM 485 OTDERS vic csoccncseesscas ioe sstscnvesonsednnsttentescchsbesssnasecondsdenstauhavdsotesaesochsneehsuney ies Nkaka 8 2 1 1 PIM 485 OTD RS Gonfieuratiotts csc 5 ce vecsluel aneio ain saai e Eaei EEEa E EEES SaN 8 2 1 2 WAPM Card Conversion Configuration ccceccssesccssessessecseeesceseeeesecseesecaeseecnaeaeseeenaeeneeaecaseaeeaeeaeeneees 9 QV DV NOG E bates E ov bea sain cons evga tes tne est cates Weve AE A ounce sabes batabeasassn eds EEEE 9 A122 RS A83 HD ecoin a A N A AA NA ELAS 9 ALZI RSA MAGCARD aan E AO ORA EEA 9 2 2 Connecting the PIM 4
29. by PIM Since Recognition Systems products maybe on the RS 485 bus with PIM s the GET OEM CODE command and the OEM _CODE response have been implemented to determine if the device polled is a PIM NOTE The data used in the OEM_CODE response has been arbitrarily selected by Schlage and has not been authorized by Recognition Systems as a unique OEM code While the PIM 485 OTD RS supports both the CRC 2 byte and CHECKSUM 1 byte for the Frame Check Sequence Schlage recommends that the CHECKSUM method be used for three reasons 1 It is one byte instead of two resulting in a smaller packet size 2 the packet size is small enough that a checksum provides adequate error detection and 3 the CHECKSUM is much easier to calculate than the CRC Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 13 of 38 CHLAGE Wireless Access ACP Command PIM Response How used POLL_WAPM_CRC page 15 WAPM_STATUS page 22 WAPM polling with CRC POLL_WAPM_CHECKSUM page 15 WAPM_STATUS page 22 WAPM polling with CHECKSUM POLL _ PIM CRC page 20 PIM_STATUS_IDLE page 23 PIM_STATUS_CHANGE page 24 PIM_STATUS_CARDDATA page 26 PIM polling with CRC POLL_PIM_ CHECKSUM page 20 PIM_STATUS_IDLE page 23 PIM_STATUS_CHANGE page 24 PIM_STATUS_CARDDATA page 26 PIM polling with CHECKSUM
30. cations port each PIM must have a unique PIM485 Addr Rules for setting Addr Lo amp Addr Hi Addr Hi must always be equal to or greater than Addr Lo Addr Hi gt Addr Lo Addr Lo to Addr Hi cannot span more than 16 Addr Hi Addr Lo lt 15 For multiple PIM 485 OTD RS s on the same communications port there cannot be any address overlap in other words on the same communications port there can be only one PIM 485 OTD RS emulating a specific reader address The reader addresses emulated by any one PIM 485 OTD RS must be consecutive Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 8 of 38 CHLAGE Wireless Access Note address 170 AAH is reserved for broadcast messages if the Addr Lo to Addr Hi range includes address 170 AAH then that PIM will control one less WAPM than normal 2 1 2 WAPM Card Conversion Configuration The CDT is used to set the card conversion configuration for a Wireless Access Point Module WAS5S2XX WA56XX WA993 WRI WPR WSM MIRL or WEXK to emulate a Recognition Systems Hand Geometry Unit Once the CDT shows that the PIM 485 OTD RS is connected and after the desired WAPM has been linked to the PIM 485 OTD RS the WAPM Configuration tab on the CDT is used to select one of three card conversions None RS_485 26b and RS _ 485 MAGCARD 2 1 2 1 None When the N
31. cket Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www it swa com Page 28 of 38 CHLAGE Wireless Access byte Field Data Description 1 Start of Frame OAH 2 Address FFh 3 Type 4FH 4 Length 02H 5 56H ascii V 6 a 31H ascii 1 7 8 Frame Check Sequence CRC or CHECKSUM Table 3 27 VIP5100 OEM_CODE Packet Format byte Field Data Description 1 Start of Frame OAH 2 Address FFh 3 Type 4FH 4 Length 02H 5 56H ascii V Tan 35H ascii 5 7 8 Frame Check Sequence CRC or CHECKSUM Table 3 28 VIP5500 OEM_CODE Packet Format byte Field Data Description 1 Start of Frame OAH 2 Address FFh 3 Type 4FH 4 Length 02H 5 56H ascii V aa ai 39H ascii 9 7 8 Frame Check Sequence CRC or CHECKSUM Table 3 29 VIP993 OEM_CODE Packet Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www it swa com P N M053 027 D Page 29 of 38 CHLAGE 3 3 7 WAPM PIM_STATUS Wireless Access byte Field Data Description 1 Start of Frame OAH 2 Address FFh 3 Type 39H 4 Length 02H 5 Ge WAPM address 00H to FEh amp not
32. eeeeeseeeeeneeneeeees 20 3 2 2 3 GET _PIM_INFO similar to SendCalibrationData ec ecesescsesecseeeeeeeceeeeceeeeceaeeeesaecaeeaeenereees 20 3 2 2 4 GET WAPM PIM_ ASSOCIATION similar to EnterIdleMode2 00 cee eeeeeeeceteeeeeeereeneeeenees 21 3 2 2 5 SET POLL similar to EnrollUser 0 cc ccccccccccceeseessceeseeeeeeseceseceseeecesecaecsaecaeecaeecaeeeeeeneeseeeeerenerees 21 3 2 2 6 SET_LINK similar to EnterIdleMode 0 ecececccescceseceseccecseecseeeneeseecaeeeaeeeeeseeeeeeeeeseneeneeneenaees 21 3 2 2 7 ABORT LINK same as Abort eceecsescsseceesecneeeecseeeecaeceeesecaecaecnaeeeesaeceeaecaeeeesnasseeeaeeeeeaeeaees 22 3 2 2 8 GET _OEM_ CODE same as SendOEMCode cccccesccesecsseeseeeseeesecaeecaeeeseeeeeeeeeeeeenereneeneeeneenaees 22 Di RESPONSE MOMMA siesena e aea e eea a aa e dace daec E eaer aine seauuex asgesseatdsseatectesass 22 3 3 1 WAPM STATUS similar to HereIsStatus response cccceesceesceeseeeeceecesecaecaeecaeecseeeaeeseeeeeeeneenas 22 3 3 2 PIM_STATUS_IDLE similar to HereIsExtendedUserRecord eecccesceeseceseceseeeeeeneeeseeseeeneeeseeses 23 3 3 3 PIM_STATUS_CHANGE similar to HereIsExtendedUserRecord cccccscecseeeceeeeeereeeseeeeeeseeeeeeees 24 3 3 4 PIM_STATUS_CARDDATA similar to HereIsExtendedUserRecord cecceeseesceeseereeeeeeeeeeeseees 26 3 3 5 NEXT _DATALOG same as HereIsNextDatalog response sssesssssseeeeeeecseeeeceeeeeeaeeeeeaeeaeeeeeneeas 28 3 3 6 O
33. guring Once the PIM 485 OTD RS is powered and connected to the PC and the CDT is running press and hold either the SA or SB switch on the PIM 485 OTD RS while pressing and releasing the Reset switch on the PIM 485 OTD RS Once the PIM 485 OTD RS LED s CR7 amp CR10 start to flash the SA SB switch can be released This places the PIM 485 OTD RS in the CDT communication mode If the CDT is shut down and restarted the PIM 485 OTD RS must be reset as indicated above to return to the CDT communication mode Once the PIM 485 OTD RS is connected to the PC and the CDT is running the Link tab on the CDT s PIM panel is used to control the PIM 485 OTD RS s Link Mode The Panel field must be set to indicate which WAPM is to be linked Table 2 6 shows the allowable range of values for the Panel field on the CDT Link tab PIM Model Panel Field PIM 485 OTD RS 0 254 address 255 FFH is reserved for the ACP address address 170 AAH is reserved for broadcast messages Table 2 6 CDT Panel Field Range of Values for PIM Models After setting the Panel field to the desired value for the WAPM being linked click the Start button to place the PIM 485 OTD RS into the link mode Power up or reset the WAPM to initialize the linking process between the PIM 485 OTD RS and the WAPM NOTE For proper operation the Panel field must only be set to the range of values for which the PIM 485 OTD RS has been configured to emulate section 2 1
34. he communication link between the WPIM and WAPM is always RF This manual describes the installation and operation of a Panel Interface Module RS485 Recognition Systems PIM 485 OTD RS a WPIM Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 5 of 38 CHLAGE Wireless Access 1 2 Panel Interface Module RS485 Recognition Systems PIM 485 OTD RS The Panel Interface Module RS485 Recogntion Systems PIM 485 OTD RS is a product in the Schlage Wireless Panel Interface Module WPIM category The PIM 485 OTD RS is the wireless interface to any Access Control Panel ACP that has a Recognition Systems Inc hand geometry access control reader interface Figure 1 2 cess td Access i Wireless Control Access Panel with RS485 PIM 485 ne Wired Access are ver RF Communication Point an j f Recognition N Communication f OTD RS Module Communication Point Systems WAPM Interface Access Control Panel Location Access Point Location from to 16 Figure 1 2 PIM 485 OTD RS Block Diagram Each PIM 485 OTD RS is connected via a 2 or 4 wire polled RS 485 interface to an ACP with a Recognition Systems interface Each PIM 485 OTD RS can control from 1 to 16 WAPM s The Schlage Configuration amp Demonstration Tool CDT is used to determine what and how many RS 485 polling addresses
35. ions 1 the polled WAPM has a loss of RF bytel 3 PIM Tamper 1 the PIM door is open 4 Cache Status 1 enabled 0 disabled 5 Motor Stall 1 the polled WAPM s lock motor is stalled 6 7d 0 1 2 byte2 2 4 Datalog Ready 1 the polled WAPM has a datalog ready 5 Configuration Mode 1 the polled WAPM is in configuration mode 6 Link Mode Enabled 1 the polled PIM WAPM is in link mode 7 0 Trouble 1 the polled WAPM has trouble i e byte1 lt gt 0 1 2 Door Position Switch 1 closed 0 open polled WAPM 3 byte3 4 Request to Exit Switch 1 inactive 0 active polled WAPM Wireless Request to Enter Wireless 1 active 0 inactive polled 5 Switch WAPM VIP LBM Status VIP 1 bolt extended 0 bolt retracted 6 Key Switch 1 key being used 0 key not being used 7 Lock State 1 unlocked 0 locked polled WAPM The Configuration Mode bit is set after the PIM receives a SET WAPM CONFIGURATION command and remains set until that WAPM communicates with the PIM A subsequent SET WAPM CONFIGURATION command must not be sent until the Configuration Mode bit is Table 3 21 WAPM_STATUS bytel byte2 amp byte3 Definitions cleared for all WAPMs linked to that PIM 3 3 2 PIM_STATUS_IDLE similar to HereIsExtendedUserRecord P N M053 027 D byte Field Data Description 1 Start of Frame OAH 2 Address FFH 3 Type 31H 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM
36. is stalled 6 7 O equest t Ee Sve These bits are set when a changed of state occurs 1 WAPM forced f a in the bytel WAPM similar to datalogs that 2 WAPM Open Too Long occur when polling by WAPM 3 Tamper Active byte3 4 5 Configuration Mode 1 the polled WAPM is in configuration mode 6 Link Mode Enabled 1 the bytel WAPM of the PIM is in link mode 7 0 Trouble 1 the bytel WAPM has trouble i e byte2 lt gt 0 1 2 Door Position Switch 1 closed 0 open bytel WAPM 3 byte4 4 Request to Exit Switch 1 inactive 0 active bytel WAPM y Wireless Request to Enter Wireless 1 active 0 inactive polled 5 Switch WAPM VIP LBM Status VIP 1 bolt extended 0 bolt retracted 6 Key Switch 1 key being used 0 key not being used 7_ Lock State 1 unlocked 0 locked bytel WAPM 0 polled PIM does not have more events to report byte5 More Events 0 lt gt polled PIM has more events to report and should be polled again The Configuration Mode bit is set after the PIM receives a SET WAPM_ CONFIGURATION command and remains set until that WAPM communicates with the PIM A subsequent SET WAPM CONFIGURATION command must not be sent until the Configuration Mode bit is Table 3 22 PIM_STATUS_CHANGE bytel byte5 Definitions cleared for all WAPMs linked to that PIM P N M053 027 D Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630
37. is stalled 6 7 O equest t Ee Sve These bits are set when a changed of state occurs 1 WAPM forced f ae in the bytel WAPM similar to datalogs that 2 WAPM Open Too Long occur when polling by WAPM 3 Tamper Active byte3 4 5 Configuration Mode 1 the polled WAPM is in configuration mode 6 Link Mode Enabled 1 the bytel WAPM of the PIM is in link mode 7 0 Trouble 1 the bytel WAPM has trouble i e byte2 lt gt 0 1 2 Door Position Switch 1 closed 0 open bytel WAPM 3 byte4 4 Request to Exit Switch l inactive 0 active bytel WAPM y Wireless Request to Enter Wireless 1 active 0 inactive polled 5 Switch WAPM VIP LBM Status VIP 1 bolt extended 0 bolt retracted 6 Key Switch 1 key being used 0 key not being used 7_ Lock State 1 unlocked 0 locked bytel WAPM 0 polled PIM does not have more events to report byte5 More Events 0 lt polled PIM has more events to report and should be polled again byte6 Card data bit count number of data bits in card data 8 252 msb of byte7 is first bit of nye carddata read from card g Card data read at WAPM either Wiegand or magnetic data up to the first 255 bits format 7 7 depends on which card conversion is being used refer to section 2 1 2 page 9 above number of bytes of card data byte38 depends on number of bits read from card The Configuration Mode bit is set after the PIM receives a SET _WAPM_ CONFIGURATION command and remains
38. isabled 01 fail unlocked 10 fail locked 6 default 00 7 Cache memory mode 0 full card number 1 facility code default 0 Table 3 11 WAPM Configuration Data Structure Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 19 of 38 Wireless Access CHLAGE 3 2 2 Commands for Addressing PIM s 3 2 2 1 POLL_PIM_CRC similar to Calibrate byte Field Data Description 1 Start of Frame OAH 2 PIM Address 00H to FEh amp not AAH 3 Type 3AH 4 Length 00H 5 CRC LSB Frame Check Sequence 6 CRC MSB 3 2 2 2 POLL_PIM_CHECKSUM similar to SendExtendedUserRecord Table 3 12 POLL_PIM_CRC Command Packet Format byte Field Data Description 1 Start of Frame OAH 2 PIM Address 00H to FEh amp not AAH 3 Type 74H 4 Length 00H 5 Frame Check Sequence CHECKSUM Table 3 13 POLL_PIM_CHECKSUM Command Packet Format 3 2 2 3 GET_PIM_INFO similar to SendCalibrationData byte Field Data Description 1 Start of Frame OAH 2 PIM Address 00H to FEh amp not AAH 3 Type 3CH 4 Length 00H 5 6 Frame Check Sequence CRC or CHECKSUM 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com P N M053 027 D Table 3 14 GET_PIM_INFO Command
39. ly 10 green led off VIP only 11 beeper on VIP only 12 beeper off VIP only 6 7 Frame Check Sequence CRC or CHECKSUM 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax www ir swa com P N M053 027 D Table 3 7 WAPM_LOCK_CONTROL Command Packet Format Ingersoll Rand Security Technologies CHLAGE Wireless Access 3 2 1 6 WAPM_TIMED_UNLOCK similar to DisplayCodedMessage NOTES 1 This command is only available in a version 2 of the PIM 485 OTD RS amp WAPMs 2 The WAPM_TIMED_UNLOCK command will only work with a battery operated Wireless Access Point Module WAPM WA52xx WA56xx WA993 WPR2 when it is sent in response to having received a card swipe data command byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 56H 4 Length 02H 5 bytel number of seconds to unlock 6 Tee byte2 always 0 7 8 Frame Check Sequence CRC or CHECKSUM Table 3 8 WAPM_TIMED UNLOCK Command Packet Format 3 2 1 7 GET_WAPM_CONFIGURATION similar to SendUserRecord byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 38H 4 Length 05H 5 WAPM Address 00H to OFH 6 0 7 Data 0 8 0 9 0 10 11 Frame Check Sequence CRC or CHECKSUM Table 3 9 GET_WAPM_CONFIG
40. one card conversion is selected the first 80 bits read from a card Wiegand proximity or magnetic are packed into the datal and data2 fields of Identity Verified datalog type 7 with byte9 bit 7 containing the first bit read see Table 3 33 page 33 below NOTE The Datalog format limits the card data to be transferred to 80 bits 10 bytes Therefore this also becomes a limit when polling by WAPM For version 1 of the PIM OTD 495 RS this 80 bit limit still applies when polling by PIM With the appropriate firmware and version 2 of the PIM OTD the number of card data bits transferred will increase to 255 2 1 2 2 RS 485 HID 26b When the RS_485 HID _ 26b card conversion is selected the 16 bit card number field bits 10 25 of a standard 26 bit Wiegand formatted card are extracted a BCD binary coded decimal 4 bits per digit conversion is done the resulting five decimal 4 bit digits are right justified and then packed into the datal field of the Identity Verified datalog type 7 see Table 3 33 page 33 below The datal field is therefore the same as the Recognition Systems ID number using a Wiegand 8 26 type reader In addition the data2 field contains the first 40 bits read from the card similar to the None conversion 2 1 2 3 RS_485 MAGCARD When the RS_485 MAGCARD card conversion is selected the data read from the card is expected to be in ABA Track 2 MagStripe format as specified in ISO 7811 The con
41. packet format Table 3 2 Field Description Start of Frame OAH indicates the start of a packet Address the address to which the packet is being sent Type the command or response type Length the number of bytes in the data field Data the data being sent it may be 0 bytes Frame Check Sequence CRC 2 bytes or CHECKSUM 1 byte Table 3 2 Communication Packet Format Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www it swa com Page 14 of 38 Wireless Access CHLAGE 3 2 Command Formats Commands are data packets sent from the ACP to the PIM 485 OTD RS 3 2 1 Commands for Addressing WAPM s 3 2 1 1 POLL_WAPM_CRC same as SendStatusCRC byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 44H 4 Length 00H 5 CRC LSB Frame Check Sequence 6 CRC MSB Table 3 3 POLL_WPAM_CRC Command Packet Format 3 2 1 2 POLL_WAPM_ CHECKSUM same as SendStatusChecksum byte Field Data Description 1 Start of Frame OAH 2 WAPM Address 00H to FEh amp not AAH 3 Type 3BH 4 Length 00H 5 Frame Check Sequence CHECKSUM Table 3 4 POLL_WAPM_CHECKSUM Command Packet Format 3 2 13 GET_WAPM_DATALOG same as SendDatalog
42. section details the data field portion of a NEXT_DATALOG response from the PIM 485 OTD RS to the ACP NOTE The data field portion of the NEXT_DATALOG response is always 18 bytes long NOTE The PIM 485 OTD RS does not do any time stamping therefore the time stamp field is always 0 filled Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 31 of 38 CHLAGE Wireless Access 3 4 1 Transaction Buffer Empty The Transaction Buffer Empty datalog is sent when a WAPM receives a GET WAPM DATALOG or GET PREVIOUS WAPM DATLAOG command from the ACP and the WAPM has no datalog to send In other words the WAPM had not set the Datalog Ready bit in the WAPM_ STATUS or PIM_STATUS response byte field description bytel address address of WAPM generating datalog byte2 byte3 byte4 byte5 byte6 byte7 byte8 format byte9 byte10 bytell datal byte12 byte13 bytel4 byte15 bytel6 data2 byte17 byte18 timestamp S O OlO o o 2 Ss x SLO OlOlOloOl o ol o Table 3 32 Transaction Buffer Empty Datalog 3 4 2 Identity Verified The Identity Verified datalog is sent when a card has been swiped or presented at the WAPM s card ready This datalog contains the data read from the card Ingersoll
43. t Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 9 of 38 CHLAGE Wireless Access RS485 products label their wires and Some products associate the signal with A some with B The bottom line is that the should always be connected to the and the to the however it is designated Reversing the polarity will not damage either RS485 device it just won t communicate So take your best guess a 50 50 chance about connecting to and to and if it doesn t work switch them NOTE If the PIM has a 9 PIN RS 232 connector it is only to be used with the CDT section 2 3 2 2 2 1 PIM 485 OTD RS using an Original PIM PCB ACP RS 485 Connector PIM 485 OTD RS J6 A B Table 2 2 RS485 Connection Original PIM PCB amp ACP 2 2 2 PIM 485 OTD RS using a RS485 PIM PCB configured for 2 wire communication ACP RS 485 Connector PIM 485 OTD RS J7 TA amp RA TBt amp RB Table 2 3 RS485 Connection RS485 PIM PCB amp ACP 2 2 3 PIM 485 OTD RS using a RS485 PIM PCB configured for 4 wire communication ACP RS 485 Connector PIM 485 OTD RS J7 R TA R TBt T RA T RB Table 2 4 RS485 Connection RS485 PIM PCB amp ACP 2 3 Linking the PIM 485 OTD RS to WAPMs 2 3 1
44. trol subcommands to WAPM LOCK CONTROL command added VIP LBM Status amp Key Switch status bits to WAPM_STATUS PIM_STATUS_CHANGE PIM STATUS CARDDATA responses 02 12 08 Changed various nomenclature and contact information made minor edits and corrections added Schlage logo changed Ingersoll Rand to Ingersoll Rand changed Security amp Safety to Security Technologies removed address from cover page changed wyreless to wireless removed all s changed www wyrelessaccess com to www ir swa com changed technical support to 866 322 1237 added notes to WAPM LOCK CONTROL amp WAPM_TIMED UNLOCK commands corrected documentation error in polarity of DPS in WAPM_ STATUS amp PIM STATUS _CHANGE responses added Request to Enter to WAPM_STATUS PIM_ STATUS _CHANGE PIM STATUS CARDDATA responses 04 01 08 Added Cache Status and Configuration Mode bit definitions to WAPM_STATUS PIM_ STATUS _CHANGE PIM STATUS CARDDATA responses Ingersoll Rand Security Technologies 245 W Roosevelt Road Bldg 7 Suite 48 West Chicago IL 60185 800 313 2962 630 293 4257 fax P N M053 027 D www ir swa com Page 38 of 38
45. version takes the first 20 characters after the start sentinel character or until the end sentinel character is detected the characters then has their parity stripped and the resulting 4 digit characters are packed into the datal and data2 fields of Identity Verified datalog type 7 with byte9 bits 7 4 containing the first character read after the start sentinel see Table 3 33 page 33 below Field separators if present are included as a separate character If 19 characters are received between the start and stop sentinels then the stop sentinel character is included as the 20 character If 18 characters are received between the start and stop sentinels then the stop sentinel character is included as the 19 and the LRC character as the 20 If 17 or less characters are received between the start and stop sentinels then the stop sentinel character and LRC character are appended to the end with any remaining unused characters being zero filled 2 2 Connecting the PIM 485 OTD RS to an ACP The PIM 485 OTD RS connects to an ACP using either a 2 or 4 wire RS485 asynchronous serial interface The communication parameters are fixed at 9600 baud 8 data bits 1 stop bit and no parity Notes about making a RS485 connection There is some confusion about the A and B designations for the RS485 signals The EIA RS 485 Specification labels the data wires as A and B but many Ingersoll Rand Security Technologies 245 W Roosevel

Download Pdf Manuals

image

Related Search

Related Contents

アシストユニット取扱説明書  ኖዙኮዙ ኌዊዙኖ ኴዊንኄ ኌኔዄዐ ኔኖኣኽ SCP716  <<< User and installation manual  Severin RG 2343 raclette  Manuale di Riferimento  MANUAL COIFA ARTICA LOFRA  NEC MultiSync LCD2070WNX User's Manual  CONTENTS  Bedienungsanleitung 2 mode d'emploi 8 instructies 13  Canules trachéales TRACOE Twist - TRACOE Medical  