InfraPower®
Contents
1. 13 16 13 O O 46 201 1 10 01 23 14 32 V16C13 4C19 324 MTS Switched 20 Connected 16 47 2044 40 14 223 4334 WARC12AC10_2948_MTS witehad Connarctan Id 4 b M IPDo 3leGro 201 101 2011100 Completed UM IPM 01 Q213V2 P 26 www austin hughes com Part IV FAQ 4 1 InfraPower Manager IPM 01 1 Whatis InfraPower Manager The InfraPower Manager IPM 01 is a Windows based system to consolidate management of max 240 PDUS via 15 IP dongles using a simple web interface which monitors and controls the MTS MI PDUs in the data center Authorized users have a secure control over outlets to power ON OFF at the man aged device level It also provides the detailed PDU and event logged records and sends alarm email once ampere overloading Please find the link below http Awww austin hughes com support software infrapower IPM 01 msi 2 Which OS platform does IPM 01 support MS Windows XP Professional with SP3 32bit only MS Windows 7 Professional with SP1 MS Windows 7 Ultimate with SP1 MS Windows Server 2003 R2 Standard Edition with SP2 MS Windows Server 2008 Standard Edition SP2 MS Windows Server 2008 R2 Standard Edition SP
2. I dome coups uU i ADU 14 V2D CT 346 19 X24 MTSITH Cnnnaripd Pium Monitor 24 Location Sarar Rack 044 vr T pr geo de TH sansar El C Deacivalp e Oe 1 Oe An of ene Alarm Satang Temp 35 0 25 Humid zu Lance Cen new date agat PDU log provides last 5000 PDU log records about a certain PDU by the user s selection The software will generate a PDU log record in every one minute IP dong groups IR ilit 14 n 3 Poel 01 88 VIBCTMACIO 32A NTS Swirhed 20 Curent Conneaded Location 007 Circun B Hama Amp Amp Co Los Alen i Load Alarm Laad 12102174 18 10 25 Rack 001 114618 328 l 13 16 12102114 14 08 24 001 18 525 a 13 16 00 SZC 18 08 25 Rak 001 RCTS TSS t 13 16 2 2114 12 07 25 Zemer 001 114219 323 5 a 13 18 00 Prase 11 iz ariarga zr ea First Frpuiaus 3 T HU 10 Had Last UM IPM 01 Q213V2 P 20 www austin hughes com Step 3 Usage amp operation Event provides last 5000 events about PDU s configuration amp connection and sensor s configuration amp connection in a certain IP dongle group 212102114 20121021 20121021 14 2012102
3. UM IPM 01 Q213V2 5 www austin hughes com 1 3 Temp amp Humidity Sensor Connection amp Specification Temp amp Humid Sensor Temperature to 80 C 32 to 176 Relative 0 to 10095 R H Humidity Accuracy 0 to 100 8 0 R H Sensitivity 20 to 80 4 5 R H Housing Chassis amp Cover Dark gray Installation Magnetic base for unrestricted installation TH sensor w 2m cable standard Cable Length TH sensor w 4m cable option Cable Specification 4 wired 3 5mm to RJ11 0 to 80 Degree Humidity 0710096 non condensing Dimensions 30L x 25Wx 18H mm Weight Net 10g InfraPower W WS Wi WSi series PDU InfraSolution X 2000 series InfraGuard Cabinet sensor system UM IPM 01 Q213V2 P 6 www austin hughes com Part Il IP Configuration and Software 2 1 IP dongle configuration After the completion of IP dongle connection please take the following steps to configure the IP dongle 1 Prepare a notebook computer to download the IP setup utilities from the link http www austin hughes com support utilities infrapower IPdongleSetup msi 2 Double click the IPDongleSetup msi and follow the instruction to complete the installation 3 Go to each first level PDU with the notebook computer amp a piece of CAT 5 6 cable to configure the IP dongle by IP setup utilities as below Please take the procedure for all dongles ONE BY ONE ZA IP d
4. 23 35 52 23 34 51 23 33 50 23 32 49 23 31 48 23 30 47 23 29 46 23 28 45 23 27 44 23 26 44 23 25 43 23 24 42 23 23 41 23 22 40 23 21 39 23 20 38 23 19 37 23 18 36 23 17 39 23 16 34 23 15 33 V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS V16C13 4C19 32A MTS Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20
5. Alarm gt Scan gt Refresh gt Temp gt Backup gt amp SNMP gt First Freacus 1 2 3 B 7 8 10 Hec 7 Last 20127 02114 Change dongle 111 aires or naggwnn 2012702 14 acrmin dangla gap 07 20121 02714 scri dongle prog 03 21121 2 14 Deacdwale IF dongle giup 04 The types af system event User 11 add Dakta Chance madi tine rali Chenge leering passen 9 op Chars ratrash mode Hima rate 11 Deactivate donga group 21 Change iP dongle address or 31 Enatle Olsable P dongle group No command password ici Enable Disable daily backup 41 Change IP dangle arcup Ha command password Charge backup path Changa temp unh Calziuz Fahrenhall 11 o Cis able dam Enable Cable SHNF 2 Changs danm amail 3aivar gating Change SNP parar setting 3j Add Delete aiam mad recipient Past sys log gt provides a search function in a certain period to find event occurrences in User gt Setup gt Alarm gt Scan gt Refresh gt lt Temp gt Backup gt amp SNMP gt Pas System Log view Lor Teast 101 roms 2012 02 2012 02 Had Laai 12112114 10 25 Change IF dongle 01 address ar passzeurd JD312 0
6. Humidity connection amp specification Part Il IP Configuration and Software 7 2 1 IP dongle configuration 2 2 InfraPower Manager IPM 01 FREE PDU management software Part Ill Data Export 23 Parl IV FAQ aA 27 4 1 InfraPower Manager IPM 01 4 2 IP dongle 4 3 Meter for MTS amp MT PDU 4 4 Others Part V Troubleshooting P 30 5 1 PDU disconnection 5 2 Replacement removal or addition for PDU amp IP dongle UM IPM 01 Q213V2 www austin hughes com Part Seup and Connection 11 PDU meter setting 8 cascade InfraPower 7 DIP Switch ON DIP Switch OFF PDU cascade port Current display 123452878 ON Dip switch 4 Reset button B For rackmount PDU e 2 on the front panel left e on the rear panel Cascaded PDUs setting Using the dip switch no 1 2 3 4 amp 8 to setup each PDU level as below Cascaded PDUs Dip switch no 1st level PDU 2nd level PDU ard level PDU 4th level PDU 5th level PDU 6th level PDU 7th level PDU 8th level PDU 9th level PDU 10th level PDU 11th level PDU 12th level PDU 13th level PDU 14th level PDU 15th level PDU 16th level PDU UM IPM 01 Q213V2 P 1 www austin hughes com 11 PDU meter setting 8 cascade 1st level PDU 2nd level PDU 3rd level PDU InfraPowe
7. UM IPM 01 Q213V2 7 www austin hughes com 2 2 InfraPower Manager IPM 01 FREE PDU management software InfraPower Manager IPM 01 is a FREE PDU management software to enhance the features and benefits of the MTS switched and MT monitored PDUs by providing a centralized and remote management platform and total reporting with detailed logs amp event occurrences InfraPower Manager IPM 01 can support max 5 concurrent login users and manage multi IP dongles max 15 hence the concurrent login users can access amp remote PDUs max 240 15 IP dongles x 16 level PDUs Step 1 Software download Prepare a management PC to download the free InfraPower Manager IPM 01 from the link http www austin hughes com support software infrapower IPM 01 msi Supported OS platform list MS Windows XP Professional with SP3 32bit only MS Windows 7 Professional with SP1 MS Windows 7 Ultimate with SP1 MS Windows Server 2003 R2 Standard Edition with SP2 MS Windows Server 2008 Standard Edition SP2 MS Windows Server 2008 R2 Standard Edition SP1 A Ensure the user logins in the management PC as a member of Administrators Group before IPM 01 Installation and execution Step 2 System setup Initial system setup lt User gt lt Setup gt lt Alarm gt lt Scan gt lt Refresh gt lt Temp gt lt Backup gt lt SNMP gt lt Sys log gt lt Past Sys log gt Step 3 Usage
8. SNMP Sys log Past Sys log Processing InfraPower Manager IPM 01 Q112V1 Logout Status Processing Details Sensor PDU log Event Past log Help UM IPM 01 Q213V2 P 23 www austin hughes com 6 Right click the PDU level below 7 Select Save Target As to download the PDU log file InfraPower Manager IPM 01 0112V1 Logout Status IP dongle groups wu Details Past Log view MM DD Max period up to 31 days E Event 3o i 3 PU Log ony CSV forma First Previous 1 2 3 4 5 6 7 8 9 10 Next Last Event PDU log Past log A To download the PDU log file please 1 Right click the PDU level below 2 Select Save target as to download the PDU log file Please take the step 1 amp 2 forthe other PDU levels one by Help Open PDU Level 01 Open in New Tab PDU Level 02 Open in Mew Window PDU Level 03 Save Target As Print Target PDU Level 04 PDU Level 05 1 y Refresh PDU Level 06 Copy Shortcut PDU Level 07 Paste PDU Level 08 3l Blog with windows Live Backup PDU Level 09 127 E mail with Windows Live SNMP PDU Level 10 Translate with Live Search All Accelerators Cut Temp PDU Level 11 sys 100 PDU Level 12 Add to Favorites PDU Level 13 Properties PDU Level 14 PDU Level 15 PDU Level 16 UM IPM 01 Q213V2 P 24 www austin hughes com 8 Select the path amp
9. Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Switched 20 Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected Connected 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13
10. Unplug the Cat 5 6 cable on the first disconnected PDU then plug it to the second disconnected PDU to check if the problem caused by the first disconnected PDU 3 GUI shows the whole group of PDU s disconnected otep 1 Cable disconnected loose or defective Check the Cat 5 6 cable connection to PDUs and network devices Make sure the connectors are firmly attached And check if any defects on your cable or not If yes replace a new one step 2 dongle failed l Check if the network setting of the IP dongle is correct or not If duplicated IP address is in a network it may cause such problem li Disconnect the IP dongle from the network and try to direct connect the Cat 5 6 cable from IP dongle LAN gt port to a computer network port and use IP Setup utilities to check if the IP dongle can be found or not If it cannot be found the IP dongle may be failed Step 3 1st level PDU failed Move the IP dongle from 1st level PDU to 2nd level PDU to check if the problem caused by 1st level PDU s failure or not If yes replace 1st level PDU UM IPM 01 Q213V2 P 30 www austin hughes com 5 2 Replacement Removal or addition for PDU amp IP dongle 1 How to replace the failed IP dongle otep 1 Prepare a new IP dongle Step 2 Disable alarm email in Alarm page otep 3 Replace the failed IP dongle with the new one on 1st level PDU otep 4 Configure the setting of the new IP dongle same as the old one Pl
11. amp operation lt Status gt lt Details gt lt Sensor gt lt PDU log gt lt Event gt lt Past log gt UM IPM 01 Q213V2 P 8 www austin hughes com Step 1 Software download Double click the IPM 01 msi and follow the instruction to complete the installation IPM 01 msi ig InfraPower Manager Setup Welcome to the InfraPower Manager Setup Wizard The Setup Wizard will install InfraPower Manager on your computer Click Next to continue or Cancel to exit the Setup Wizard Cancel jx InfraPower Manager Setup Select Installation Folder This is the Folder where InfraPower Manager will be installed To install in this Folder click To install to a different Folder enter it below or click Browse Folder c Program Files InfraPower Manager Advanced Installer Cancel UM IPM 01 Q213V2 P 9 www austin hughes com Step 1 Software download 2 InfraPower Manager Setup Ready En Install The Setup Wizard is ready to begin the InfraPower Manager installation Click Install to begin the installation IF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Advanced Installer 2 InfraPower Manager Setup Installing InfraPower Manager Please wait while the Setup Wizard installs InfraPower Manager This may take several minutes Status Advanced Installer Back Next gt ix Inf
12. analysis purpose IPDongleGroupOt1 LevelO1 20111001 20111001 Compatibility Mode Microsoft Excel Viewer Open Quick Print Copy Find Go Print Switch Print Preview Setup Area Windows Office Document Page Setup Window n ala PEN 1 t num L Date Time Model Name Status Circuit amp Circuit A load amp Circuit A alarm amp Circuit B max amp Circuit load amp Circuit B alarm amp Total load amp 2 2011 10 01 23 59 14 V16C13 4C19 32A MTS Switched 20 Connected 16 13 16 13 3 2011 10 01 23 58 13 V16C13 4C19 32A MTS Switched 20 Connected 16 13 16 13 F G 1 J L 4 2011 10 01 5 2011 10 01 6 2011 10 01 7 2011 10 01 8 2011 10 01 29 2011 10 01 10 2011 10 01 11 2011 10 01 12 2011 10 01 13 2011 10 01 14 2011 10 01 15 2011 10 01 16 2011 10 01 17 2011 10 01 18 2011 10 01 19 2011 10 01 20 2011 10 01 21 2011 10 01 32 2011 10 01 23 2011 10 01 124 2011 10 01 35 2011 10 01 6 2011 10 01 28 2011 10 01 2011 10 01 31 2011 10 01 32 2011 10 01 33 2011 10 01 34 2011 10 01 35 2011 10 01 36 2011 10 01 37 2011 10 01 38 2011 10 01 39 2011 10 01 40 2011 10 01 41 2011 10 01 42 2011 10 01 43 2011 10 01 44 2011 10 01 45 2011 10 01 23 57 12 23 56 11 23 55 10 23 54 10 23 53 09 23 52 08 23 51 07 23 50 06 23 49 05 23 48 04 23 47 03 23 46 02 23 45 01 23 44 00 23 42 59 23 41 58 23 40 57 23 39 56 23 38 55 23 37 54 23 36 53
13. and slide out the failed IP dongle from the MTS MT PDU Then replace a new one for the PDU and re configure the IP address to fit your network setting Please refer to the user manual P 5 UM IPM 01 Q213V2 P 28 www austin hughes com 4 3 Meter for MTS amp MT PDU 1 Whatis feature of the MT PDU The MT PDU offers simple amp highly reliable power distribution to multiple equipments and built in a digital ampere meter indicates the total power consumption of equipment connected to the PDU The digital ampere meter has an interface which can connect to an IP dongle to the ethernet network which allows managers to real time remote monitor the PDU load thru the InfraPower manager IPM 01 2 Whatis feature of the MTS PDU The MTS PDUS offers the same features as MT PDUS with an addition remote control power capability to individual PDU outlets The remote outlet power control allows power on off functionality for power recycling to reboot locked up equipment and to avoid unauthorized use of individual outlets 3 Which types of outlet can MTS PDU support The MTS PDU supports IEC 60320 C13 IEC 60320 C19 NEMA 5 15 20R amp BS1363 outlet type 4 the MTS and MT PDUs cascade together Yes the MTS amp MT model PDUs can connect together as a cascade chain 5 If one of the cascaded MTS MT PDU loses power will it affect other PDUs in the same chain No the other cascaded MTS MT PDUs in upper amp lower level will n
14. power fluctuation or failure Use of supplies or parts not meeting our specifications Normal wear and tear Any other causes which does not relate to a product defect B Removal installation and set up service charges Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures B Re position or relocate the receiving antenna B Increase the separation between the equipment and receiver B Connect the equipment into an outlet on a circuit different from that to which the receiver is connected The company reserves the right to modify product specificatio
15. 1 A Ensure the user logins in the management PC as a member of Administrators Group before IPM 01 Installation and execution 3 Which database does the IPM 01 support PostgreSQL 4 What is the PostgreSQL default password for 012 1qazaWSX 5 Howcanlreceive alarm email and get full log report Ensure that IPM 01 is executed and the alarm server is configured properly and being enabled 6 What is the default login name amp password of 012 Default login name admin amp password 00000000 7 What is the command password of 012 Each IP dongle group has its command password It will be requested for any PDU configuration and control The administrator can set different command password for different IP dongle group or all IP dongle groups use the same password 8 The MTS MT PDUs can t be found by IPM 01 Please double check the cable connection and the level setting of each PDU If a cascade chain has duplicate the level PDUS it will cause this problem 9 Is it possible to manage the MTS MT PDUs from different workstations Yes the InfraPower manager supports 5 concurrent login users from different workstations UM IPM 01 Q213V2 27 www austin hughes com 10 Canthe MTS MT PDUs connect the KVM switch Yes only CyberView IP KVM switch In this connection IP dongle will not be needed For the details please find the link below http www austin hughes com support usermanual infrapo
16. 14 712102114 112102113 43212 02114 22012102113 201210213 210112 102 13 912102113 48 The of avant FEU coniguration POU POU comiguration FOU comiguration POL comiguration POU cpni guration POU POL comguration POL conriguration FEU cpmigurzationi POL commguratien Lari 51180 lag Ti nnm Change name POU Level 01 duit D4 name POU Level D1 Quiet 03 Change aul name FOU Level 01 Julit 02 Change autict name POU Level D1 Quiet D1 Switch putet on POLI Level 01 Ouigl 04 Ewflch puia POU Level Culgi 3 Switch oiei an POU Leser 02 Sich pudgi an POU Laul 71 Oude d1 Change alam amp POU Leser on Chou B Change alarm amp POU Level 041 Cuit A Change POL name POL Level 01 Fil connection Sansor configuration Distraction Reconnection 11 Change alam amp i Oru Cirult n TH aenanr 2 Change POU rame 2 Change temp alarm 31 Change POU location 3 Changa humid alarm 14 Sean putet on off 4 Temp alan RC TE OH Change name Humid atarm Disconnedion Reconnection Amp alam IP donge connection Disconnection Reconnection UM IPM 01 Q213V2 P 21 www austin hughes com Step 3 Usage amp operation Past log provides a search function in a certain period to find the l
17. 152 166 01 POPS part 161 eria TL Gor Liner Username d1 20 cMax el minutes ida To i ERI i poy UM IPM 01 Q213V2 15 www austin hughes com Step 2 System setup Scan IP dongle groups auto scan 5 Min 5 secs Max 60 secs Cancel Scan rate Apply lt Refresh gt Auto data refresh Refresh rate 20 Min 10 secs 60 secs Backup gt Data backup setting Daily backup Enable Disable Backup to ea Example C Program Filesi SNMP gt SNMP server setting SNMP Enable Disable IP address 192 168 0 1 Community public Apply Download MIB file UM IPM 01 Q213V2 P 16 Auto scan rate on the page Auto data refresh rate on the amp pages Daily backup proceeded at 00 00 for last 24 hours data The backup data for saved in text file format Folder InfraPowerDataBackup will be automatically created under the path vou entered The SNMP server setting allows you to enable or disable SNMP communication between 01 and SNMP manager 01 SNMP server must be enabled for this feature to work Download the file to assist you in configuring SNMP manager to retrieve data i www austin hughes com Step 2 System setup Sys log gt provides last 5000 events in User gt Setup gt lt
18. 2718 1B OO 25 Deactivate dongle cg ec 02 2042 09 14 46 0B 2b sdrrin Deadeate dongle group 03 2012 02 14 1 017 25 Bat admin Deartivatu IP dongle grup 04 gt UM IPM 01 Q213V2 P 17 www austin hughes com Step 3 Usage amp operation Status provides the users a scan function to monitor the PDUs of each IP dongle group one by one amp set the alarm amp for the PDU dongle groupe 0 IF Jonge name Marne address 122 16 1 40 Circus B Fam L ucalipn Tip Man Load i 20 Rack 0411 00 A 18 0 0 Switched 20 Rack 002 m 1 Sliced 20 Rack DJ 00 33 10 45 Swfichad 20 Rack 004 1 20 Serar Rark O4 43 1n AD Monitor 11 Rack 004 Monitor 10 Sera Rack QU 45 Morio 18 Sera Rack Ond 44 Monitor 18 Rack Od 45 Monitor 15 Serer Rark 10 16 Mrritnr 15 Server Rark 011 AT 18 Rack 012 45 Morin 24 Sera Rack 011 a5 Monitor 24 Rack O14 43 Monitor 24 O15 Rad 018 dat retra 1 unter during dara in tree Bex E gVA ans diia qaare gearch raw PLUS Pres Fi iio or diragmt ing acres UM IPM 01 Q213V2 P 18 www austin hughes com Step 3 Usag
19. 8 18 16 18 18 18 18 18 16 18 16 45 Carell A Low Mamm 5 5 S 5 5 5 5 5 5 z z 5 amp 5 5 5 5 z 5 15 15 16 1 16 18 1 amp 8 15 18 15 15 16 15 15 18 16 16 16 15 15 18 1 16 16 16 B Te Load Alarm 00 13 00 13 13 0 0 13 n 13 00 13 D 13 00 13 ig 13 0 0 13 n 13 00 12 D 13 n 13 6 0 13 D 13 13 0 0 13 00 13 n 13 00 13 ud 13 13 0 0 13 00 13 Tata Lnad 00 D D 181 Dg 00 00 00 00 00 00 Dg Da 0 0 D 0 0 00 00 D 00 D D b 00 Completed www austin hughes com Part Ill Data Export Select IP Dongle group Tick the box of PDU log amp ignore the PDU level selection Click and a Message from webpage dialog box pops up 3 Enter the period of PDU log to export min 1 day max 31 days Click OK to confirm the export process It may take several minutes to complete InfraPower Manager 01 0112 1 Logout Status IP dongle groups 01 02 03 05 06 oz 08 o9 1o 11 12 13 44 35 Details Past Log view YYYY MM DD Max period up to 31 days ELEME Lootpe PDU log From i 10 i 1 PDU log Event To 10 31 i i For PDU Log only in CSV format Event First Previous 1 9 10 Next Last Past log Message from webpage fx Help Are you sure to export Refresh Temp nd 1
20. InfraPower Intelligent Remote Power Management User Manual IPM 01 PDU management software MTS switched PDU MT monitored PDU 111714 HL Designed and manufactured by Austin Hughes UM IPM 01 Q213V2 www austin hughes com Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference B Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth B Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit B When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing dam age to other equipment or injury to persons nearby B When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating m Arrange the equipments power cord in such way that others won t trip or fall over it B f you ar
21. P13 www austin hughes com Step 2 System setup In Setup page the administrator can activate the IP dongle group amp set the group command password ome couv IIR please sahaj che IP one one DO MOT acne the grou P dosage and FOL conseckan IP dongle group 01 e Each grasp careat fone P dopage and 16 POL dangle setting i Fheinnzgirxor eani charge F dong sites aed fern dep IP dangle address 182 108 1 0 ums debis rcx ee ri Firei asier the D natus bo maka ite change ruf ia lag page 5 tan tpisis page to make ihe sane ckarpe os P Poe 101 dongle meup Command password e Enade CI Diable peii omenan pasa wori im OOD LATTA needs Iz set command tor P doe grape ens ay enn Pow password i PaaS lrrwrmnd p rani reqeeied For arr POU cenfgurbon and 5 Adminalraor can set cone passera fer differenc P doage poin ir a Fdongk Ehe same passer UM IPM 01 Q213V2 P 14 www austin hughes com Step 2 System setup Alarm Alarm email server setting anri ems Enab 2 L isable Tha saim esting m for all F donge POL groups SMTF 152 188 D 1 ZMTF part 26 POPS aar
22. PDU InfraPower InfraPower InfraPower CAT 5 6 CAT 5 6 cable cable Up to 20 meters Up to 20 meters To LINK port of the 1st PDU To LINK port of next PDU Up to 16 levels UM IPM 01 Q213V2 P 3 www austin hughes com 1 2 IP dongle installation amp connection IP dongle for rackmount PDU Horizontal IP dongle installation steps fix the IP dongle on the rear side of rackmount PDU with 4 screws plug the RJ 45 connector of IP dongle into the LINK port of the 1st level PDU meter use the CAT 5 6 cable to connect IP dongle to network device Rear side of rackmount PDU To LAN port Customer s network device router or hub 77 47 fa 47 47 47 47 UM IPM 01 Q213V2 P 4 www austin hughes com 1 3 Temp amp Humidity connection amp specification MT MTS meter provides 1 sensor port for Temp amp Humidity monitoring The user can see the Temp Humidity reading not only from the local meter display but also from remote management software low profile design with magnetic base for easy affixing to the rack cabinet Plug n Play sensor with 2M or 4M cord Temp amp Humid Sensor Model IG THO1 2M 2M IG THO1 4M 4M Temperature A e User MUST order TH sensor option before delivery The length of the PDU may be increased by 50mm e e e e
23. Power Manager start up setting Please follow the instruction to complete your own setting Click Next to continue or Cancel to exit InfraPower Manager Software component s analysis amp installation The following 3 software component s are required to run InfraPower Manager 1 Apache 2 2 Please decide to use the existing or new Apache 2 2 C Use existing Apache Install new Apache 2 2 Tick this if the management PC has been already installed Apache Folder CAAppSenA Port 2 PHP 5 Please decide to use the existing or new PHP 5 f Use existing PHP Install new PHP 5 Tick this if the management PC has been already installed PHP Folder CAAppSen 3 PostgreSQL 9 0 Please decide to use the existing or new PostgreSQL 9 0 C Use existing PostgreSQL Install new PostgreSQL 9 0 Tick this if the management PC has been already installed PostgreSQL Folder C Program Files PostgreSQL 9 PostgreSQL login postgres PostgreSQL password 1qaz2W5X Install Cancel Completed A PostgreSQL password can be changed by user The password of PostgreSQL must contain at least three of the following four character groups English uppercase characters A through Z English lowercase characters a through z Numerals 0 through 9 Non alphabetic characters such as UM IPM 01 Q213V2 P 12 www austin hughes com Step 2 System setup Users can follow below step 1 3 to access the managem
24. click to complete the download process Please take Step 6 7 amp 8 for the other PDU levels one by one nfraPower M anager IPM 01 Q112V1 Logout Status IP dongle groups 02 03 6 Details Past Log view Sensor Log type PDU log B ces Save in 2 Desktop 4 Documents X My Computer My Recent Network Places Past log Documents E IPDongleGroupO1 Level01 20111002 20111101 Help A To download the PDU log file 3 1 Right click the PDU level bel Desktop 2 Select Save target as to do Please take the step 1 amp 2 fo PDU log Event First Previous 1 Tees My Documents PDU Level 01 PDU Level 02 Alarm PDU Level 03 My Computer Scan PDU Level 04 PDU Level 05 a File name ongleGroup0s Level 20111001 201110216 Refresh PDU Level 06 My Save as type csv Document Temp PDU Level 07 PDU Level 08 PDU Level 09 PDU Level 10 Sys log PDU Level 11 Past Sys 4 log Setup Backup Download complete Te Download Complete 01 20111001 20111031 csv From 127 0 0 1 Downloaded 3 3UMB in 1 sec Download Ea AIPDonglearoup Bs Level 1 20111001 20111031 c Transfer rate 3 50MB Sec Close this dialog box when download completes UM IPM 01 Q213V2 P25 www austin hughes com e Below is the sample of a PDU log file in MS Excel CSV format e User can use the data for
25. e amp operation Details gt provides a detailed status about a certain PDU The user can not only set the name amp location for PDU amp each outlet but also power ON OFF the outlets one by one for switched PDU POL exl m 18 328 5 s ahus Cpnneckcd Gre A Max mre 16 Load Amg Hama 1 S ner 1 2 Bam r 2 3 3 1 11 um Penes d 1 Sun_Senver_2 i Chen Rotari 17 HP 1 1B BladwSever 20 data Save sme ian Cancel new dain Peciorydefeut Rese POU m estinga POU Frees 01 greet fg UM IPM 01 Q213V2 Mame Switched 20 Location Sener Rack 001 On OH CN 19 Outer Kim Amp TB 2550558 672 Flame Sera 4 EM Dol Berr 3 Dui Soror 4 miem LA Sun_Server_4 Cisco Rone 2 HF Blacesenver 3 arpi 4 Amp arr oh arr ON arr ON 2 pasas ord reqaesied pusem www austin hughes com Step 3 Usage amp operation Sensor
26. e using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labelled on the equipments electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipment s ratings label Observe all precautions and warnings attached to the equipment B If you dont intend on using the equipment for a long time disconnect it from the power outlet to prevent being dam aged by transient over voltage B Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock B Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invali date its warranty B If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover B Any product on which the serial number has been defaced modified or removed B Damage deterioration or malfunction resulting from Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by us Any damage of the product due to shipment Removal or installation of the product Causes external to the product such as electric
27. ease refer to P 5 for IP dongle configuration otep 5 Click Start Connection in Status page for the relevant IP dongle otep 6 Enable alarm email in Alarm page again 2 How to replace the failed 1st level PDU with a new one otep 1 Prepare a new PDU and set the PDU to 1st level Please refer to P 1 for the PDU level setting Step 2 Disable alarm email in Alarm page Step 3 Power off amp unplug the device s which connected to the PDU otep 4 Power off amp remove the failed 1st level PDU from connection otep 5 Install the IP dongle on the new 1st level PDU otep 6 Install and connect the new PDU otep 7 Power on the new PDU and connect to the device s otep 8 Click Start Connection in Status page for the relevant IP dongle otep 9 Configure the new PDU in Status and Details page such as Alarm Amp Name Location Step 10 Enable alarm email in Alarm page 3 Howto replace affailed certain level PDU with a new one otep 1 Prepare a new PDU and set the PDU level accordingly Please refer to P 1 for the PDU level setting otep 2 Prepare an appropriate length Cat 5 6 cable otep 3 Disable alarm email in Alarm page otep 4 Use the Cat 5 6 cable to bridge over the failed PDU which will be replaced to minimize log data loss otep 5 Power off amp unplug the device s which connected to the failed PDU otep 6 Power off amp remove the failed PDU from connection otep 7 Install
28. ent PC and InfraPower Manager IPM 01 System authentication Step 1 Open Internet Explorer I E version 7 0 or above User name Step 2 Enter the IP address of management PC into the address bar If fail to access please ask MIS to check the service port of the management PC Step 3 Enter the user name the default is admin Enter the password the default is 00000000 Password 2 e Login user Login user Router or hub gt Management InfraPower Manager IPM 01 Only Administrator is authorised to access lt User gt lt Setup gt lt Alarm gt lt Scan gt lt Refresh gt lt Temp gt lt Backup gt amp lt SNMP gt for initial system setup In User page the administrator can create max 5 concurrent login users and set the user name amp password After this all users can take the three steps above to access IPM 01 Pe admin On anna access user Seng Sc Peran Tere Pusat ing a ni miran mirata sa arc Stee a ee wor 4 char 18 cne for user pene char ged rama 18 ches foc user peeved jee mw change p user rare m poeraio pmi cregie 3 new gis gamer is eee viiam ong ken wong gt UM IPM 01 Q213V2
29. ns without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2011 Austin Hughes Electronics Ltd All rights reserved UM IPM 01 Q213V2 www austin hughes com Unpacking The equipment comes with the standard parts shown on the package contents Check and make sure they are included and in good condition If anything is missing or damage contact the supplier immediately Package contents 1 Vertical MTS MT PDU x 1 VMS mounting screw set of 2 or 3 VMB mounting bracket set 49 M6x2 M6nutx2 2 3 sets 2 Rackmount MTS MT PDU x 1 A All electrical power and power control wiring must be installed by a qualified electrician and comply with local and national regulations Power ON B Connect the PDU into an appropriately rated receptacle B When the PDU is power on the LED display will light up That means all outlets are activated B Keep the equipments in the power off position until it is plugged into the PDU A Don t exceed the outlet branch or phase limitations UM IPM 01 Q213V2 www austin hughes com Content Over IP connection via IP dongle Part Setup and Connection 4093 ee SOY ACA P 1 lt 1 15 PDU meter setting 8 cascade 1 2 IP dongle installation amp connection 13 Temp amp
30. og records about a certain PDU or the event occurences about a certain IP dongle group dongie groups ct Mex period e 1 days aut Li export POULE ory n CEV Sorani Past Lag view POU lag Event Laval d 38 Lag First Previouz 1 201210214 112 Dz H 2012 102 14 21112 02 114 2012 102 14 212 102 14 21712 1092314 2210214 112102114 2012 1027 14 2012 102 44 21112102 14 2112 102114 2042 02 14 2042 2 14 20120214 201210214 112 102 14 2012102114 112 Dz 14 2012 102 0 14 21112 02 1 14 2012 102 114 21112 102 14 11112102114 UM IPM 01 Q213V2 HLC12 324 4TS 13 324 13 32 4 12 323 5 4013 325 HLC3 324 MTS 4 13 325 13 32 5 4 13 328 4 5 13 328 4 5 4013 328 5 213 32 5 4013 325 40213 325 HLU13 324 MT8 4213 325 5 13 32 4 13 325 5 HLC12 325 4TS 4013 328 5 HeC12 325 MTS 12 22 4013 325 HLC13 324 MTS 4 13 324 Connected Connected Connected Connected Cone cbad Connacted Connacbad Connacred Connacbad Connecred Connected 4 40 Connected Connacbad Connected Connecbad Connected Connected Connected Connacbad Connaced Pinna chad P 22 Na 18 15 16 16 18 16 45 18 16 18 16 18 1 1
31. ongle on ist level PDU CAT 5 6 cable Mx To notebook computer To IP dongle SY lt gt LAN port LAN port Reconnect the IP dongle with the network device router or hub after finish dongle configuration Ensure the PDU in power ON status D IP setup utilities for IP Dongle Yer Q411Y1 Infra Power Intelligent Remote Power Management IP Dongle list Configuration Device MAC address 00 00 50 05 1 Name EE Location Rack 001 Password New password Confirm new password IP address 192168017 Write down the new IP address amp password Subnet mask 552552580 00 for lt Setup gt purpose refer to P 13 Gateway 19216802354 00 Save Close 4 Click Scan to search the connected IP dongles 5 Enter the device name in the name field min 4 char max 16 char The default is Name 6 Enter the location in the location field min 4 char max 16 char The default is Rack 001 7 Enter the password in the password field for authentication min 8 char max 16 char The default is 00000000 8 Enter the new password in the new password field min 8 char max 16 char 9 Re enter the new password in the Confirm new password field 10 Change the desired IP address Subnet mask Gateway then click Save to confirm the setting to IP dongle 11 The default IP address is as below IP address 192 168 0 1 Subnet mask 255 255 255 0 Gateway 192 168 0 254
32. ot be affected 6 Whatis the maximum cabling distance between two cascaded PDUs Up to 20 meter 66 feet of CAT 5 6 cable 7 Whatis the maximum cascade level of the MTS PDU in a chain 16 levels 4 4 Others 1 Doesthe InfraPower PDU has the overpower protection Yes the PDU provides the resettable fuse or optional circuit breaker for the overpower protection 2 Whatis the standard inlet cable length of InfraPower 3 meter 9 9 feet 3 Where can find the Catalogue User manual Model list Wire diagram of InfraPower PDUs Please visit the www austin hughes com 4 How can we get a further support Please send the email to support 2infra power com or sales infra power com UM IPM 01 Q213V2 P 29 www austin hughes com Part V Troubleshooting 5 1 PDU disconnection 1 GUI shows certain level PDU disconnected otep 1 PDU power off Check the PDU is power ON or not otep 2 PDU level setting duplicated in the same PDU group Check and make sure PDU level is unique and not duplicated in the same PDU group Please refer to P 1 for the PDU level setting 2 GUI shows from a certain level PDU to the last oneidisconnected otep 1 Cable disconnected loose or defective Check the Cat 5 6 cable connection to PDUs and network devices Make sure the connectors are firmly attached And check if any defects on your cable or not If yes replace a new one otep 2 The first disconnected PDU failed
33. r InfraPower InfraPower CAT 5 6 CAT 5 6 cable cable Up to 20 meters Up to 20 meters C To LINK port of next PDU Up to 16 levels IP dongle refer to P 3 9 12345678 12345678 1 23 45 6 7 6 Dip switch setting Dip switch setting Dip switch setting B Ihe PDU can be cascaded up to 16 levels B For IP PDU access simply connect 1 x IP dongle IPD 01 B dongle allows access to 16 levels Meter display setting Using the dip switch no 5 amp 7 to setup each PDU meter display as below Current display Dip switch no Circuit A Circuit B Circuit A only Circuit B only Audio alarm Using the dip switch no 6 to setup each PDU audio alarm as below Dip switch 6 On Disable O UM IPM 01 Q213V2 P 2 www austin hughes com 1 2 IP dongle installation amp connection To remote PDU over IP users can order IP dongle IPD 01 IP dongle for vertical PDU Vertical IP dongle installation steps slide the IP dongle on the plate above the meter plug the RJ 45 connector of IP dongle into the LINK port of the 1st level PDU meter use the CAT 5 6 cable to connect IP dongle to network device To LAN port CTi Q Customer s network device router or hub IP dongle IP Remote Access rEsET B Please refer dip switch setting on P 1 2 for different level PDUs 1st level PDU 2nd level PDU 3rd level
34. raPower Manager Setup Completing the InfraPower Manager Setup Wizard Click the Finish button ka exit the Setup Wizard Cancel UM IPM 01 Q213V2 P 10 www austin hughes com Step 1 Software download Double click the InfraPower Manager IPM 01 and follow the instruction to complete start up setting InfraPower Manager A For MS Windows 7 and MS Windows server 2008 it requires to run a program with administrator rights before execution Right click InfraPower Manager IPM 01 and then select Properties Click the Compatibility tab Tick the box Run this program as an administrator and then click OK 01 Properties x Security Details Frevious Versions General Shortcut Compatibility IF you have problems with this program and it worked correctly on an earlier version of Windows select the compatibility mode that matches that earlier version Help me choose the settings Compatibility mode Run this program in compatibility mode for Windows XP Service Pack 3 Cut Settings Run in 256 colors Run 640 x 480 screen resolution Disable visual themes Disable desktop composition Disable display scaling on high DP settings Properties Frivilege Level Iw Run this program as an administrator Change settings for all users UM IPM 01 Q213V2 P 11 www austin hughes com Step 1 Software Download rd InfraPower Manager Infra
35. stall and connect the new PDU otep 5 Power on the new PDU otep 6 Click Search in Status page to search the new installed PDU Step 7 Configure the new PDU in Status and Details page such as Alarm Amp Name Location Step 8 Enable alarm email in Alarm page If the added PDU in the last level youMUST reconfigure and reset the level for the affected PDU s which next to the added PDU The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2013 Austin Hughes Electronics Ltd All rights reserved UM IPM 01 Q213V2 P 32 www austin hughes com
36. the new PDU cancel the cable bridging and reconnect the PDU to the last and next one otep 8 Power on the new PDU and connect to the device s otep 9 Configure the new PDU in Status and Details page such as Alarm Amp Name Location Step 10 Enable alarm email in Alarms Ignore step 2 amp 4 if the failed PDU is in the last level UM IPM 01 Q213V2 P 31 www austin hughes com 5 2 Replacement Removal or addition for PDU amp IP dongle 4 How to move out a PDU without a replacement otep 1 Prepare an appropriate length Cat 5 6 cable Step 2 Disable alarm email in Alarm page Step 3 Use the Cat 5 6 cable to bridge over the removed PDU to minimize log data loss otep 4 Power off amp unplug the device s which connected to the PDU otep 5 Power off amp remove the PDU from connection otep 6 Click Disable Monitoring in Details page to stop monitoring the removed PDU Step 7 Enable alarm email in Alarm page If the removed PDU in the last level you MUST reconfigure and reset the level for the affected PDU s which next to the removed PDU A Ignore step 1 amp 3 if the removed PDU is in the last level 5 How to add an extra PDU to an existing PDU group otep 1 Prepare a PDU and set the PDU level accordingly Please refer to P 1 for the PDU level setting otep 2 Prepare an appropriate length Cat 5 6 cable Step Disable alarm email in Alarm page otep 4 In
37. wer UM IPS 01 pdf 11 Does the IP dongle support web browser access Yes the IP dongle features a browser based built in graphical user interface GUI that can configure monitor and power control to individual outlets For the details please find the link below http www austin hughes com support usermanual infrapower UM P PS 01 pdf 4 2 IP dongle 1 Whatis the IP dongle The IP dongle provides a simple and economical way to consolidate management of max 16 pcs MTS MT PDUs by a single IP connection to the network 2 Whatis the IP setup utilities This is a windows application used to assign the IP address of IP dongle You can download the IP setup utilities from the link below http www austin hughes com support utilities infrapower IPdongleSetup msi 3 Doesthe IP dongle support DHCP Dynamic Host Configuration Protocol No the IP dongle only works with static IP address 4 How can I reset the IP dongle password to the factory default value Press the reset button of IP dongle for at least 8 seconds to reset the IP dongle to the factory default value as below IP address 192 168 0 1 Password 00000000 5 Will the reset of IP dongle affect the power to the outlets No the IP dongle operates on a separate circuit so the power to the outlets will remain unchanged 6 How I replace a failed IP dongle As the IP dongle is hot swappable without power disconnection you can unplug the RJ45 connector