Home

BLANCCO LUN FOR WINDOWS

image

Contents

1. N CCO COM o Blancco Oy Ltd Lansikatu 15 80110 Joensuu Finland Tel 358 207 433 850 Fax 358 207 433 859 sales blancco com www blancco com
2. Bee blancco CERTIFIED DATA ERASURE BLANCCO LUN FOR WINDOWS User Manual VERSION 2015 1 3 2 4 all Compatible with Windows 8 CERTIFIED FOR i 1 Windows Microsoft Compatible Vista Windows XP Windows Windows ERIHFIESEER SERDEN Server 2012 2 Server 2012 Windows Windows Microsoft TA ip Wind Certified Certified Servers200882 Servere2008 Server 2003 Designed for ABSTRACT This is the official Blancco LUN for Windows User Manual Blancco is the proven data erasure solution for millions of users around the world As the pioneer and global leader in data sanitization and end of lifecycle solutions the company offers the most certified data erasure within the industry Blancco LUN allows data storage administrators to securely erase individual drives as well as logical drives such as LUNs in an active storage environment blancco 2 31 DEFINITIONS To execute some actions on a computer administrator rights may be required This means that only the person with permission and unrestricted access or the administrator has the rights to implement said act The line on the display screen where a command is expected Generally the command NE command line is the line that contains the most recently displayed command prompt A console based program uses a text based interface Many console moie e e Diskp
3. EN 5 EAEN E 6 Administrator Rights nnn nnn nnn nn nnn nnn nnn nnn nn nnn i nnn nnn i ennt enne enne nene 6 Iristall Uniristall 55 E A 7 ar ui 7 7 7 Uaec 8 Ui e e E 8 ist attached drives mM 9 pido ETE 10 11 Erase multiple drives nennen nnne 12 Erasure 5 14 REPOMING e 16 CONTGUIATON asi aii erie ii aie ea Eua ia i eerie ta saeva ton tl a etu sn tu eaae Een RR ux gena 16 License management c deseen ud xL dede do ee Edo erc Ll quedes es edes 17 Extra fields and info fields in the log files and the GUI sssssemH Hee 19 Automatically connect to the Management Console 20 Importing the reports manually to Blancco Management Console for 21
4. set to dynamic as illustrated in the following picture n C Windows system32 cmd exe size set to dynamic Application exiting You can also set a specific buffer size as seen here C Windows system32 cmd exe New buffer size 268435456 Buffer size set to 268435456 6x1 66680000 gt gt Application exiting blancco 25 31 The buffer size can also be set in the Windows Registry To do this the following path must be manually created HKEY_LOCAL_MACHINE SOFTWARE Blancco SITShredding Settings Once in this location create a DWORD with the name Au ferSize and then modify the value To set it as dynamic the following value should be given BufferSize 4294967295 in hex ffffffff Here is an example with a 50MB buffer The buffer size used needs to be BufferSize 52428800 divisible by 1024 In this example the buffer size is set to 50 MB blancco 26 31 Email the report automatically advanced option You can choose to automatically email the report to a specified email address This setting will override the settings shown in the setup GUI above The report format will depend on the template settings chosen in the previous chapter These options allow you to send XML HTML and PDF reports The e mail function will send the format you have activated through the template settings You can either hardcode an email address in the Setup Tool or a use dynamic valu
5. Changing the local log 22 Generate HTML and PDF report from a customized nnne 23 scm 24 Email the report automatically advanced option 0 eee ee nnnm nnn nnns 27 Short Message Service SMS Letra as certes Da dk EUER ae Duran ap Ere BON apa 28 Met 29 Contact information ocior iiie toile ree eda ia riae vana un teen dava ea a dun t dna ava COS dux o aea agen eder 30 26 blancco 4 31 BLANCCO LUN Blancco LUN is created for demanding enterprise environments where secure data erasure of individual disks or logical disk units such as LUNs needs to be performed in active data storage environments and systems FEATURES AND REQUIREMENTS Key Features e Shred any type of disk drive supported by Microsoft Windows including IDE SCSI FC and iSCSI e Easy to use administrative interface based on command line e Multiple drives can be shredded concurrently and or simultaneously Supports all leading data erasure standards which enable compliance with different policies and regulations referring to erasure standards e Detailed secure reporting based on XML format compliant with Blancco Management Console for centralized reporting System Requirements Windows Server 2012 R2 2012 2008 2003 all versi
6. DEFAULT ALGORITHM 1 1 HMG Infosec Higher standard 3 2 Peter Gutmann s Algorithm 35 3 U S Department of Defense Sanitizing DoD 5220 22 M 3 4 Bruce Schneier s Algorithm 7 5 Navy Staff Office Publ 3 6 NCS Center 4 7 Air Force System Security 4 8 US Army 3 9 Not currently in use 7 10 OPNAVINST 5239 1A 3 11 NSA 130 1 3 12 DoD 5220 22 M ECE 7 13 BSI 2011 VS similar 3 14 BSI GS 2 15 BSI GSE 3 50 Random 1 Random 1 round of overwriting based on pseudo random data generated by host OS PRG You also have the option to view the erasure standards with the command standards as seen below nistrator C Program Files Blancco Blancco LUN gt BlanccoLUN exe standards HMG Infosec Standard 5 Lower Standard HMG Infosec Standard 5 Higher Standard Peter Gutmann s Algorithm DoD 5226 22 M Bruce Schneier s filgorithm Navy Staff Office Publication CNAUSO 5239 26 National Computer Security Center CNCSC TG 8 25 gt Air Force System Security Instructions 5626 U S Army AR3S amp 8B 19 9 German Standard BSI USITR OPNAVINST 5239 1 NSA 136 1 DoD 5226 22 M BSI 2611 US Similar Application exiting C Program Files Blancco Blancco LUN gt blancco 15 31 REPORTING The solution will log information about the shredding in log files These log files can be handled by an administrator The report includes time date and the serial number from the unit being erased a
7. b6bf 11d8 gt Drive number 2 Drive name Sumo lt gt Drive letter E Device name Hitachi HDS72161 KLA336 Device path name PhysicalDrive2 Device adaptor Intel R gt ICHSR ICH9R ICH18R DO SATA RAID Controller Device model HD 72161 KLA Device vendor Hitachi Device bus IDE Device bus type RAID Device port Device path Device target 2 Device LUN Device disk id F6E2REF4 Device sectors 1953525168 Device serial TG H BAPSGZJHU Device size 931 51 Device path idelttdiskhitachi_hds721616k1a330 4819 gt Drive number 3 Drive rive letter Device name IET VIRTUAL DISK SCSI Disk Device Device path name PhysicalDrive3 Device adaptor Microsoft iSCSI Initiator Device model UIRTUAL DISK Device vendor IET Device bus SCSI Device bus type iSCSI Device port 3 Device path Device target Device LUN Device disk id 4D4B71CD Device sectors 20971520 Device serial 9528139 9 419899143197 13144 Device size 16 00 Device path scsilfldisk amp ven_iet amp prod_virtual disk 181c121344868600600H lt 53F56 gt blancco 9 31 As seen in the example picture Blancco LUN lists information per drive This information includes the actual path as well as the unique ID for a listed disk or a listed logical unit This ID is called Device disk id in the list Diskpart The same drive list is shown in Microsoft utility DISKPART list
8. xml after the value Note Any value can be used as the file name If the extra field is not specified the registry value will be used as file name directly Example If log if specified the log file will be named log xml 22 31 Generate HTML and PDF report from a customized template As a default an XML log is generated Also a HTML report is created from a template file This HTML file is also used for creating a PDF file The PDF format is set so you cannot change the information in the PDF file once it is generated The default setting is that all formats are generated To change this change the registry settings as described below You can create a custom designed report by changing the special template that is included in the solution You can also change the path to the template if necessary with registry settings Note These registry settings are the same no matter if you have 32 or 64 bit systems Defines the path to a template used when generating a customized report If this value does not exist no extra report is generated Possible values Defines if a pdf are 0 and 1 should be generated of the 0 Don t make template generated pdfs report If emailing 1 Make pdfs of the report is from the activated the pdf is template report sent Path to the T lateFilePath emplateFilePat template MakeLogIntoPdf 59 gt blancco 23 31 Buffer size Blancco LUN supports a v
9. disk Status Storlek DISKPART gt The drives are represented by the same numbers in DISKPART as in the Blancco program Tip If the user is more familiar working with DISKPART DISKPART can be used to identify the correct drives and then use Disk nrto start the erasure process mee Bee blancco 10 31 Erase a drive To start an erasure use the parameter shred followed by the algorithm of choice and which drive or drives to shred with space in between each new input value Example shred 0 3 5 This example will shred drive three using the HMG Infosec Baseline standard After the completion of drive number three drive number five will be shredded with the same algorithm The algorithm is selected by the number in the table below and the drive by the number presented in the list produced by the parameter ist Each erasure has to be confirmed by a Yes before the operation starts If you are sure that you have selected the correct drive you can add y into the command line to skip the confirmation question During the erasure the administrator can follow the progress Gis Blancco LUN Eraser ele Blancco LUN Eraser is shredding drive number 1 Ib ttttththhhthhhhnbbhhbi A 1 Speed 3 99 MB s Elapsed time Time left 66 66 43 Picture Erasure in progress Bee blancco 11 31 After the operation is complete the p
10. license Please contact your sales representative to go through these licensing options Chee 7 E C ERASE LUN ERASE LUN ERASE LUN te solaris MANAGEMENT CONSOLE Picture Overview of Blancco LUN all options The Windows version is marked in red Administrator Rights Required The solution is designed for shredding the whole drive It will first remove any partitions and file systems on the drive to free up the whole writeable area After that it will overwrite the whole writeable area on the drive sector by sector according to the selected erasure standard In Windows you need to have administrator rights to be able to write directly to a device Hence you need to start the solution as administrator blancco 6 31 INSTALL UNINSTALL Evaluation Blancco LUN is available through your local Blancco representative Contact us to receive an evaluation version of the software or for licensing information Install Install the solution with the self extracting compressed executable This opens an installation wizard that will guide you through the necessary installation steps The installation package can also be delivered as an msi package upon request Uninstall Use Add Remove Programs in the Control Panel to remove Blancco LUN blancco 7 31 USER GUIDELINES The solution consists of a console based program running on a Windows system and is started f
11. ariety of different storage equipment Depending of the type of storage the amount of I O sent at one time can affect the performance of the erasure The user can affect this amount by changing the parameter BufferSize If the BufferSize parameter is not set the software will try to use the preferred size specified by the hardware and the operating system Especially in high end storage systems this size is normally too small to get the optimal erasure performance Note that Blancco LUN requires double the amount of RAM based off of the buffer size For example if the buffer size is 512MB then 1024MB of RAM will be used If you want the software to automatically change the buffer depending on the current performance and are defining this value in Command Line Interface the value Z can be used The buffer size then changes each minute depending on the current performance If the same storage is erased over and over again the most efficient is to manually specify a buffer size that is believed to optimize performance The software will then run the entire operation with the specified buffer size The buffer size used needs to be divisible by 1024 To change the buffer size give the command BlanccoLUN exe buffersize as seen below Em Administrator CAWindov C Program Files Blancco Blancco LUN gt BlanccoLUN exe buffersize blancco 24 31 You will then be prompted to enter the new buffer size By entering the value Z it will be
12. art is a command line utility that supports the use of scripts to LELNNNP US 4B OO DWORD consists of two WORDs which is equal to 32 bits Administrator rights HASP key HASP key is inserted in a USB port and contains the Blancco licensing data HTML which stands for Hyper Text Markup Language is the predominant markup language for web pages It provides a possibility to create structured documents by denoting structural semantics for text such as headings paragraphs lists etc as well as for links quotes and other items IDE SCSI FC and iSCSI are all types of drives with different capacities and traits They differ in everything from cable amount drives per bus and transmitting capacity Logical Unit Number is a unique number from 0 to 7 used to identify a logical unit or SCSI devices e g external hard drives String is a data type consisting of a sequence of characters A string is often LLENO T eXtensible Markup Language is a markup language that defines a set of LERNEN D 0 REN IDE SCSI FC and iSCSI jae blancco 3 31 TABLE OF CONTENTS EUN EY 5 Features and Requirements nna aan 5 KEY FEATURES EE 5 2 22 02 reap d 5 System
13. cified in international format always starting with zeros do not use the sign In the example above the number starts with 00358 for a Finnish number To enable the SMS service during an erasure add the optional parameter s s Example shred 0 3 5 sms 00358207433850 In this example the HMG Infosec lower standard will be used 0 to erase LUN 3 and 5 and SMS messages will be sent to number 00358207433850 every two hours with progress reports An SMS will be sent to the specified cell phone number when the operation is performed The SMS will contain information about the outcome of the operation and duration time An SMS progress report will look like this Blancco LUN has completed x of the drive drive number LUN specified in job combined with manufacturer and model on computer name Speed xy MB s Elapsed time hh mm ss Time left hh mm ss During the operation the service will send an SMS every second hour updating the operator about the progress The SMS service has no understanding of office hours Therefore an SMS can be sent to the receiving cell phone during night time as well mee blancco 28 31 TROUBLESHOOTING No PDF log file is generated Make sure that NET 2 0 is installed Remote erasure Verify that you have a stable connection and avoid using modem connection for erasure purposes Sufficient user rights Make sure that the account you are using has full access to the unit units where the
14. d sco Setup NN NN blancco 7 User cannot change value Extra2 User cannot change value o License Management Example of adding Extra fields into the Blancco LUN report blancco 19 31 Automatically connect to the Management Console To automatically send reports into the Blancco Management Console you need to specify the Server address User name and Password in the Management Console Settings fields The User name and Password should be the same as the account on the Blancco Management Console where you want the reports from the selected product to end up To also add information into the report fields Business name and Erasure person use the Optional log information fields in the same box The reports generated can also be sent directly by email from the erasure client In the Mail settings section please specify the right information r 3 Blancco Setup Tool Se License Management blancco Choose product All Listed Products v Extra Fields Configuration Management Console Settings Serveraddress User name Password Optional log information Business name Erasure person Mail settings SMTP Server To Address CC Address From Address SMTP Login SMTP Password Connect to the Blancco Management Console add report information and send report also via e mail blancco 20 31 Importing the r
15. e based on the extra fields shown above If you want to give the operator the possibility to set the to address for the email when running the software follow these steps 1 Create a new Extra Field The number of the field is not important 2 Set the Name to MailReportToAddress 3 If the operator should be prompted default address create a string value called Default with the desired default value This can be changed by the operator 4 If the operator should not be able to change the default value create a DWORD called Disabled and set the data value to 1 This will overrun the registry settings done by the Blancco Setup Tool for the to address But you can still add a carbonate copy address to receive a copy of each report Blancco LUN Eraser E LUN Eraser is shredding drive number 1 Enter extra and info field information MailReportToAddress info blancco con mee blancco 27 31 Short Message Service SMS If your license agreement includes the SMS text message module you can receive an SMS when the operation is ready You can also follow the progress of the operation as long as have access to your cell phone To test the service you can send a text SMS to yourself to see if it comes through Please note that an internet connection is required for the host computer where Blancco LUN is running Example sms 00358207433850 The cell phone number should be spe
16. eports manually to Blancco Management Console for Windows The XML reports generated can also be manually imported into the Blancco Management Console for Windows The reports are available one by one or all at once The single files are named after date and time when the operation started in minutes and the file with all reports is called all xml To import the reports into the Blancco Management Console the HASP key needs to have a license for Blancco LUN as a product reports were imported successfully Select the Blancco XML report file you want to import Browse _ No selected Example of view after successful import If a successful import of all reports has been made we recommend that you remove the all xml which will create a new file that includes only the new reports made that are not yet imported into the database blancco 21 31 Changing the local log path The default log path is under the application data path for the local user To change this to another local path or to a central storage point other than the Blancco Management Console please create the following registry value nee Bee tee LogPath LogFileNa me blancco Extra 1 Value The value identifies the folder in which the log file will be saved An option to rename the actual log report file This example will take the value of the Extrai field the report and use that as the name The program will add
17. erasure will be executed Failed erasure clean up and rebooting When erasing LUN s connected to clustered servers it is necessary to power down all other servers in the cluster except the one to be used to perform the erasure This is to ensure that the other servers in the cluster don t reserve the hard drives thus preventing access to the hard drives and causing the erasure to fail In some circumstances it may be necessary to also force a cleanup on the server you are using to perform the erasure In the case of Wintel servers this can be done by accessing the Command prompt and typing the following command cluster node servername forcecleanup It may also be necessary to then reboot the server after running this command if the hard drives are still not accessible blancco 29 31 CONTACT INFORMATION Visit the technical knowledgebase FAQ and contact Blancco Technical Support by submitting a technical support ticket at http support blancco com See the instructional videos for Blancco products at http Awww blancco com en videos For contact information and the latest information about secure data erasure solutions visit the Blancco website at http Awww blancco com We are always looking for ways to improve our products Please let us know if you have any suggestions mee blancco 30 31 as use bee For further information please visit A A A D VV VV VV D v V V blancco
18. ons Windows 8 1 Windows 8 7 Vista and XP all versions The Windows OS installed on suitable hardware with Aminimum of 15 MB of free disk space 10 of free RAM Mouse or keyboard Appropriate drivers for the drives to be erased 2 0 or later required to be able to use full reporting functionality 32 bit and 64 bit systems both supported System Overview Blancco LUN is a Windows based solution That means it has the ability to erase all units that a Windows system can detect and use If any unique drivers need to be installed in order to make the drive work in Windows these have to be installed before the erasure is performed Any logical disk unit or individual disk correctly attached to a Windows system with the solution installed can be securely erased on the logical level The solution is optimized for individual disks or logical disk units such as LUNs and does not try to dissolve any raid configuration or access the hardware without using the BIOS blancco 5 31 The solution erases the mounted user accessible part of functional drives and assemblies of drives Licensing The license system is connected to the Blancco Management Console and the Blancco HASP system The HASP key used must be activated with the solution ID the number of gigabytes possible to erase as well as the agreed end date in a contract There are also options to license the solution per system or under a site
19. rogram clearly indicates if the operation was successful or not The program also displays where the log file has been saved Please see example of both successful and failed operations below Administrator Blancco LUN Eraser fs Blancco LUN Eraser is shredding drive number 1 Speed 4 12 MB s Elapsed time 00 01 02 Time left 66 66 06 Log file was created C UsersS AppData Roaming Blancco Blancco LUN Eraser Logs xm1 2611 May 65 18 2011 1043 1 Application exiting C Program Files x86 gt Blancco Blancco LUN Eraser gt Picture Successful shredding Administrator Blancco LUN Eraser b les Blancco LUN Eraser Blancco LUN Eraser is shredding drive number 1 Drive number 1 could not shredded successfully Speed 4 00 MB s Elapsed time 66 66 68 Time left 00 00 55 Log file was created AppData Roaming Blancco Blancco LUN Eraser Logs xm1 2611 May 5 18 2011 1 48 xm1 Application exiting C Program Files x86 gt Blancco Blancco LUN Eraser Picture Unsuccessful shredding Erase multiple drives simultaneously By giving the following command multiple drives will be erased at the same time multishred In the following example drives 8 12 13 and 14 will be erased multishred 0 8 12 14 blancco 12 31 C Program Files Blancco Blancco LUN gt BlanccoLUN exe multishred O 8 12 14 Blancco LUN 1 3 2 6 4 target
20. rom a console that is running with administrator user rights Usage When installing the software a program folder is chosen When starting a program from the Windows command line you need to be in the program folder to begin with A normal installation will give the following path for starting the program C Program Files Blancco Blancco LUN BlanccoLUN exe As seen above you start the actual program by using the actual exe name BlanccoLUN exe This starts the program and Blancco LUN is displayed When you start the program from the console without any parameters or with 2 the program will print out a short help instruction as seen below E Administrator C Windows System32 cmd exe C Program Files Blancco Blancco LUN gt BlanccoLUN exe Blancco LUN 1 3 2 0 LUN syntax BlanccoLUN exe command Commands list Lists the drives available on the machine shred lt algorithm gt lt drive number gt drive number sms cell phone number 66358267433856 1 Starts a shredding of the selected drive with the specified algorithn multishred lt algorithm gt lt drive numbers gt Shred multiple disks at the same time multishred 8 18 12 7sms lt cell phone number 6635826743385 gt Sends a test text message to the number provided setup Opens the setup GUI for configuring the Management Console connection standards Show available algorithms buf fersize Set the buffersize to determine the
21. rver Edition Blancco HMG Blancco Stealth Activation amp Licensing Blancco Stealth Erasure Blancco Mobile Edition Blancco Data Centre Edition Blancco Profiler Blancco File Blancco Flash Blancco Sparc Edition Blancco Management Console for Linux Blancco Management Console for Windows Blancco Demo per HDD Blancco Asset Manager per HDD Blancco Lite per HDD Blancco PC Edition per HDD Blancco Server Edition per HDD Blancco HMG per HDD Blancco Stealth Activation amp Licensing per HDD Blancco Stealth Erasure per HDD 0 1 2 3 4 5 6 7 8 9 Example of product list shown with number of licenses available blancco 18 31 Extra fields and info fields in the log files and the GUI The extra info fields are added into the report by using the Blancco Setup Tool Click the Management Console Setup button located in Settings In the Setup Tool window see below choose product Blancco Flash In the Extra Fields tab add a new field by pressing the below These fields are named 1 Extra2 or Infoi Info2 and so on choose Extra or Info fields depending on your current usage of the Blancco Management Console and how data fields are integrated into other systems etc The most common is to use the Extra fields Choose product Blancco LUN Field name Default value 7 Mandatory Extra Field Default value Mandatory Extra Field Info Fiel
22. s are specified for erasure shred 8 ended with shred 12 ended with shred 13 ended with shred 14 ended with All targets are done Application exiting C Program Files Blancco Blancco LUN Upon completion the value 0 indicates a successful erasure while 1 indicates a failure If for example the given command was multishred 0 600 8 9 but drive 600 did not exist the output would be as follows shred 0 600 ended with 1 shred 0 8 ended with 0 shred 0 9 ended with 0 In order to not be forced to confirm each erasure you can add y to the command line The erasures will then start without any prompting On the next page we see an example of four drives being simultaneously erased blancco 13 31 Blan Blancco LUN 1 3 2 8 Blancco LUN 1 3 2 0 Blancco LUN i hredding drive number 8 RXXKRRRERE AM 14 Speed 7 35 MB s Elapsed time 0 00 17 Time lef Program Files Blancco Blancco LUN gt BlanccoLUN exe multishred 8 12 14 Blancco LUN 1 3 2 0 4 targets are specified for erasure Blancco LUN Me number 13 GS See ceucinv se mu umm M wu m dm Ue Mw 1 6 06 17 Time left 8 14 25 Erasure standards The following erasure standards are available as default Others can be requested and implemented as part of a contracted solution blancco 14 31 Overwriting Number Erasing Algorithms as used above rounds 0 HMG Infosec Lower standard
23. s well as information about the user and erasure standard There are also optional extra fields that are possible to include into the report format CONFIGURATION All the settings for the reporting are done through registry values that can be set by using the Blancco Setup Tool The Setup Tool allows you to configure license management include extra fields in the report process and also enable automatic connection to the Blancco Management Console See the below paragraphs for how to use the Blancco Setup Tool Start this tool by using parameter setup Alternatively use the Windows Start menu and Setup Tool under Blancco LUN blancco 16 31 License management When you click the red field license management you can choose which product you want to set up in the drop down list and then if you want to activate licensing from a local Blancco HASP key or from a HASP key in the Blancco Management Console o License Management blancco Activate licenses If you check the box show all products you will see a list of all Blancco products and the current number of licenses available to you on the selected HASP key blancco 17 31 GS License blancco Choose product Listed Products Extra Fields Configuration Local HASP Management Console Show all products Product ID Product Name Blancco Demo Blancco Asset Manager Blancco Lite Blancco PC Edition Blancco Se
24. size of the 1 0 blocks 7 Show this message Application exiting C Program Files Blancco Blancco LUN gt blancco 8 31 List attached drives The parameter ist shows all the drives attached to the machine that can be securely erased Tip The drive does not need to be mounted or represented by a drive letter in order to show up in the list Driue number 8 Drive name Kung Foo lt Drive letter Device name WDC UD388BHLFS 81G6U8 Device path name PhysicalDrive Device adaptor Intel R ICHSR ICH9R ICH18R DO SATA RAID Controller Device model HLFS 1G6U Device vendor WDC WD38 Device bus IDE Device bus type RAID Device port Device path Device Device LU Device disk id 23B7EB58 Device sectors 586072368 Device serial W DRWGT4C899084 Device size 279 46 Device path ideltldiskwdc_wd3888h1fs 81g6u8 904 04 0114819 Drive number Drive name Storage D gt Drive letter D Device name Storage Device path name PhysicalDrivei Device adaptor Intel lt R gt ICHS8R ICH9R ICH18R DO SATA RAID Controller Device model Raid 1 Volume Device vendor Intel Device bus IDE Device bus type RAID Device port Device path Device target 1 Device LUN Device disk id BED71A78 Device sectors 1953519616 Device serial nr Storage Device size 931 51 Device path ideltdiskstoragel 6 66_ 4819feaa6c8O8G 1 68 lt 53 56307