Home
FUNCTION manual
Contents
1. LED indicates activity within the circuit Non Inverted Signal OUT Non inverted signal from the FUNCTION circuit Buffered and capable of accurately driving a 4 way multiple 8V peak to peak when Cycling Otherwise this output will follow the amplitude of the input EOR EOC LED Indicates the states of the EOR and EOC outputs When RED EOC is HIGH and EOR is LOW When Green EOR is HIGH and EOC is LOW End Of Rise OUT Goes high at the end of the Rise portion of the function OV or 10V End Of Cycle OUT Goes high at the end of the Cycle or Falling portion of the function OV or 10V Inverted Signal OUT Inverted signal from the FUNCTION circuit Buffered and capable of accurately driving a 4 way multiple 8V peak to peak when Cycling Otherwise this output mirrors the input amplitude Overview FUNCTION is part of the MATHS family of control voltage utility modules It is a small analog computer designed for musical purposes Amongst other things the Function will allow you to 1 Generate a variety of linear logarithmic or exponential triggered or continuous functions 2 Generate discrete time functions 3 Integrate an incoming signal 4 Invert an incoming signal 5 Generate analog signals from digital information Gate Clock 6 Generate digital information Gate Clock from analog signals 7 Delay digital Gate Clock information If the above list reads like science rather than music here is the translation 1 Voltage
2. Controlled Envelope or LFO 2 Stepped voltages like Sample and Hold Track and Hold Staircase LFO 3 Apply Lag Slew or Portamento to control voltages 4 Modulate backwards 5 Musical Events such as Ramping up or Down in Tempo on command 6 Initiating Musical events upon sensing motion in the system 7 Musical note division and or Flam Indeed the FUNCTION is a direct descendent of MATHS sharing the same core circuit complete with some evolutions 1 since most Make Noise modules have attenuators on the CV inputs the scaling inversion feature has been replaced with dedicated Non Inverted Inverted outputs This is useful as you could have the same signal modulating two different destinations in opposition 2 As FUNCTION is single channel design we included both EOR and EOC There is interesting things you could do with these outputs such as flams see patch tips Much like CH 1 and 4 on the MATHS multiple FUNCTIONs can also be used to program complex functions using EOR and EOC 3 The evolution in the circuit is the HANG input On Gate HIGH at the HANG IN the FUNCTION is stopped dead in its tracks With HANG you can program Stepped LFOs Synchronized Functions using multiple of clock S amp H Track amp Hold Clock Run Stop using EOR or EOC out for Clock and more Tips amp Tricks Longer cycles will be achieved with more Logarithmic response curves The fastest sharpest functions will be achieved with extreme exponent
3. any function If Inverted out is patched to Fall CV IN Log Rise w Expo Fall is achieved By setting Vari Response to Linear combinations of Linear and Expo or Log are possible Envelope Follower Apply Signal to be followed to Signal IN set Rise to NOON Set and or modulate FALL Time to achieve different amounts of Smoothing Take output from Non Inverted Signal OUT Increasing the Fall Time to beyond 70 will result in the Peaks being held for long periods of time EOR and EOC will also indicate activity at the Signal IN A variation on this patch has EOR patched to the HANG IN The Peak is detected and held until user resets by removing patch cable from HANG IN Multiplication VCA Apply positive going Control Signal to be multiplied to Signal IN Set Rise and Fall to full CCW Apply positive going Control Signal multiplier to BOTH Control IN Take output from Signal OUT Patch Ideas Digital Gates Clocking Typical Voltage Controlled Pulse Clock LFO Same as Voltage Controlled Triangle Function only the output is taken from EOC or EOR Using EOR the RISE parameter will more effectively adjust frequency and FALL parameter will adjust pulse width Using EOC the opposite is true where Rise more effectively adjusts Width and Fall adjust frequency All adjustments to Rise and Fall parameters will affect frequency HANG input will act as Start Stop control with the Clock STOPPING when you send a Gate HIGH to HANG FLIP FLOP 1 Bit Mem
4. signal patched to HANG IN Clock signal must be wide in order to achieve S amp H In other words the clock should be HIGH most of the time going low for only a short time An example of this type of clock signal would be to use another FUNCTION or a channel of a MATHS Use the EOC with Fall set to Full CCW and setting the Rise to determine the rate The Rise and Fall parameters determine the range of possible values Track amp Hold Signal to be processed is patched to Signal IN Clock or Gate signal patched to HANG IN Signal will pass to the Signal OUT with the Rise and Fall parameters determining the slew rate When the HANG IN goes HIGH the Signal OUT will be held at the current voltage until the HANG IN goes Low Staircase Function Triggered or Continuous Set up for Typical Voltage Controlled LFO see above Patch clock signal to HANG IN Clock should be at higher frequency then that of the function
5. CYCLE Button Causes the circuit to self cycle thus generating a repeating voltage function aka LFO Use for LFO Clock VCO Rise Panel Control Sets the time it takes for the voltage function to ramp up CW rotation increases Rise Time Rise CV IN Linear control signal input for Rise parameter Positive Control signals increase Rise Time Negative control signals decrease Rise Time with respect to the Rise panel control setting Fall Panel Control Sets the time it takes for the voltage function to ramp down CW rotation increases Fall Time Function Panel Controls cont d 8 12 13 19 16 17 Both CV IN Bi Polar Exponential control signal input for entire FUNCTION Contrary to the Rise and Fall CV IN BOTH has an Exponential response and Positive control signals decrease total time while Negative control signals increase total time Fall CV IN Linear control signal input for Fall parameter Positive control signals increase Fall Time Negative control signals decrease Fall Time with respect to the Fall panel control Vari Response Panel Control Sets the response curve of the voltage function Response is continuously variable from Logarithmic through Linear to Exponential to Hyper Exponential The Tick mark shows the Linear setting HANG IN Gate or Pulse applied to this input will stop the circuit dead in its tracks Use for programming S amp H Track and Hold Stepped Functions Stepped LFOs synchronized Functions
6. Function Limited WARRANTY Make Noise warrants this product to be free of defects in materials or construction for a period of one year from the date of purchase proof of purchase invoice required Malfunction resulting from wrong power supply voltages backwards or reversed eurorack bus board cable connection abuse of the product or any other causes determined by Make Noise to be the fault of the user are not covered by this warranty and normal service rates will apply During the warranty period any defective products will be repaired or replaced at the option of Make Noise on a return to Make Noise basis with the customer paying the transit cost to Make Noise Please contact technical makenoisemusic com for Return To Manufacturer Authorization Make Noise implies and accepts no responsibility for harm to person or apparatus caused through operation of this product Please contact technical makenoisemusic com with any questions needs amp comments otherwise go MAKE NOISE http www makenoisemusic com A THANK YOU Beta Analyst Peter Speer Test Subjects James Cigler Spiritual Advisor Richard Devine Special Thanx to MATHS INSTALLATION Electrocution hazard Always turn the Eurorack case off and unplug the power cord before plugging or un plugging any Eurorack bus board connection cable cable Do not touch any electrical terminals when attaching any Eurorack bus board cable The Make Noise FUNCTION is an
7. electronic music module requiring 30mA of 12VDC and 30 mA of 12VDC regulated voltages and a properly formatted distribution receptacle to operate It is designed to be used within the Eurorack format modular synthesizer system Go to http www makenoisemusic com systems shtml for examples of Eurorack Systems and Cases To install find necessary space in your Eurorack synthesizer case confirm proper installation of included eurorack bus board connector cable on backside of module see picture below plug the bus board connector cable into the Eurorack style bus board minding the polarity so that the RED stripe on the cable is oriented to the NEGATIVE 12 Volt line on both the module and the bus board On the Make Noise 6U or 3U Busboard the negative 12 Volt line is indicated by the white stripe 12V Please refer to your case manufacturers specifications for location of the negative supply Function Panel Controls 1 2 Signal IN Direct Coupled input to circuit Use for Lag Portamento S amp H T amp H and ASR Attack Sustain Release type envelopes Trigger IN Gate or Pulse applied to this input will trigger the circuit regardless of activity at the Signal IN The result being a OV to 8V function aka Envelope whose characteristics are defined by the Rise Fall and Vari Response parameters Use for Envelope Pulse Delay Clock Division LFO Reset only during Falling portion CYCLE LED Indicates CYCLE ON or OFF
8. ial response curves Adjustment to the response curve will affect Rise and Fall Times To achieve longer or shorter Rise and Fall Times than available from Panel Controls apply a voltage offset to the Control Signal Inputs Extremely long cycles may be achieved by setting Rise and Fall to about 50 and patching a slow clock to HANG It helps to have control over the WIDTH of the gate clock applied to the HANG input so another MATHS or other modules with Gate clock width control such as Pro Modular CLOQ will be very handy Use the Inverted Signal OUT where you require reversed modulation but do not have means for inversion at the CV destination no attenuvertor Feeding the Inverted Signal OUT back into the FUNCTION at any of the CV inputs is highly useful see patch tips Patch Ideas Analog Control Voltages Voltage Controlled Transient Generator Attack Decay Envelope A pulse or gate applied to the Trigger IN starts the transient function which rises from OV to 8V at a rate determined by the Rise parameter then Falls from 8V to OV at a rate determined by the Fall parameter This function is re trigger able during the falling portion Rise and Fall are independently voltage controllable with response as set by the Vari Response panel Control Voltage Controlled Sustained Function Generator A S R Envelope A gate applied to the Signal IN starts the function which rises from OV to the level of the applied Gate at a rate dete
9. ory In this patch Trigger IN acts as the Set input and BOTH Control IN acts as the Reset input Apply Reset signal to BOTH Control IN Apply Gate or logic signal to Trigger IN Set Rise to Full CCW Fall to Full CW Vari Response to Linear Take Q output from EOR NOT Q from the EOC OUT This patch has a memory limit of about 3 minutes after which it forgets the one thing you told it to remember Voltage Controlled Pulse Delay Processor Apply Trigger or Gate to Trigger IN Take output from End Of Rise RISE parameter will set the delay and Fall parameter will adjust width of the resulting delayed pulse Voltage Controlled Flam Apply Trigger Clock or Gate to Trigger IN Set Rise for Full CCW Fall for at least 50 Take output 1 from End Of Rise and patch to Optomix CH 1 Strike IN Take output 2 the Flam from EOC patch to Optomix CH 2 Strike IN Apply Signal s to be Flammed at Optomix Signal IN 1 and 2 Monitor SUM out Flam control is performed with the Fall parameter Voltage Controlled Clock Divider Clock signal applied to Trigger IN is processed by a divisor as set by Rise parameter Increasing Rise sets divisor higher resulting in larger divisions Fall time adjusts the width of the resulting clock If the Width is adjusted to be greater than the total time of the division the output will remain high Take output from EOR or EOC Sample amp Hold Signal to be processed is patched to Signal IN Clock
10. rmined by the Rise parameter The function Sustains at that level until the Gate signal ends then Falls from that level to OV at a rate determined by the Fall parameter Rise and Fall are independently voltage controllable with variable response as set by the Vari Response panel Control Typical Voltage Controlled Triangle Function LFO Push Cycle Button Cycle LED lights Set Rise and Fall Panel Control to NOON Apply desired modulation to BOTH CV input Setting Rise and Fall parameters further CW will provide longer cycles Setting these parameters further CCW will provide short cycles up to audio rate The shape of the resulting function may be varied from LOG to LINEAR to EXPO using the Vari Response panel control Typical Voltage Controlled Ramp Function LFO As above only the Rise parameter is set FULL CCW Fall parameter is set to at least NOON Fall parameter as well as the BOTH control voltage IN determines the rate VC LAG Slew Processor Portamento A signal applied to the Signal IN is slewed according to the RISE and FALL parameters Variable response from Log through Linear to Exponential as set by the Vari Response panel Control Portamento is traditionally LOG response The inverse of the resulting function is available at the Inverted Signal OUT Independent Contours Expo Rise w Log Fall and vice versa Set Vari Response to Full CCW for Log response Patch Inverted OUT to Rise CV IN This yields Expo Rise with Log Fall for most
Download Pdf Manuals
Related Search
Related Contents
ARCTIC Audio Relay Moxa EDR-G902 Ethernet LAN Grey router manual de instruções câmera color ccd com infravermelho Icom iM90 User's Manual Copyright und Garantie Casio Edifice 3H3EDD User's Manual 仕様書 Mobiltelefon M130 Bedienungsanleitung Copyright © All rights reserved.
Failed to retrieve file