Home

Acapulco BP2100 en

image

Contents

1. BALBOA water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 6 12 08 11 Fill it up Preparation and Filling Fill the spa to its correct operating level Be sure to open all valves and jets in the plumbing system before filling to allow as much air as possible to escape from the plumbing and the control system during the filling process After turning the power on at the main power panel the top side panel will display a splash or startup screen Priming Mode M019 After the initial start up sequence the control will enter Priming Mode and display a Priming Mode screen Only pump icons appear on the priming mode screen The system will automatically return to normal heating and filtering at the end of the priming mode which lasts 4 5 minutes During the priming mode the heater is disabled to allow the priming process to be completed without the possibility of energizing the heater under low flow or no flow conditions Nothing comes on auto matically but the pump s can be energized by selecting the Jet buttons If the spa has a Circ Pump it can be turned on and off by pressing the Circ Pump button during Priming
2. This system incorporates two temperature range settings with independent set temperatures The specific range can be selected on the Settings screen and is visible on the Main Screen in the upper right corner of the display These ranges can be used for various reasons with a common use being a ready to use setting vs a vacation setting Each range maintains its own set temperature as programmed by the user This way when a range is chosen the spa will heat to the set temperature associated with that range High Range can be set between 80 F and 104 F Low Range can be set between 50 F and 99 F More specific Temp Ranges may be determined by the Manufacturer Freeze Protection is active in either range BALBGA weter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 5 12 08 11 The Settings Screen Continued Heat Mode Ready vs Rest In order for the spa to heat a pump needs to circulate water through the heater The pump that performs this function is known as the heater pump The heater pump can be either a 2 speed pump Pump 1 or a circulation pump If the heater pump is a 2 Speed Pump 1 READY Mode will cir
3. 3 Open the computer control box compartment under the computer display by loosen the screw and then open the compute box prepare the accordingly cooper cable the length will be enough to connect to the family power supply with electrical plug one side and another side without plug and then take the empty side of cable from electrical cable channel to go through the pump compartment to the channel of control box compartment connect it to control box according to the following illustration 4 Clean and wax your spa shell and cover your spa has been thoroughly tested during the manufacturing process to ensure reliability So there s a small amount of water even within some grease may have remained in the plumbing after testing as a result ay have spotted the spa shell the spa shell the spa siding prior the delivery so before filling spa it is a need to put some new water to wash it and then wipe the spa shell clean with a soft rage or some acrylic cleaner and wax it if possible OPERATING INSTRUCTIONS 1 Close the drain and fill the spa with water After closing the drain put your garden hose inside the tub and turn your water on to fill the spa and the water level should be maintained approximately 1 above the top of the highest jet keep an eye on everything as filling If you see any leak or flood anywhere turn off the water until it will be fixed First check the main house CIRCUIT BREADER that controls the electric t
4. Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 10 12 08 11 Additional Settings Light Cycle Option If Light Cycle does not appear in the Settings Menu the Light Timer feature is not enabled by the manufacturer When available the Light Timer is OFF by default The settings can be edited the same way that Filter Cycles are edited see page 10 Back Invert Panel Selecting Invert Panel will flip the display and the buttons so the panel can be easily operated from inside or outside the hot tub Dedicated Buttons Specific Buttons for Specific Devices If the panel has dedicated function buttons TP800 or the spa has an Auxiliary Panel s installed pressing those buttons will activate the device indicated for that button These dedicated buttons will operate just like the Spa Screen buttons see page 4 and the equipment will behave in the same manner with each button press BALBOA water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 othe
5. The Spa Screen and Shortcut Screen All Equipment Access The Spa Screen shows all available equipment to control as well as other features like Invert in one easy to navigate screen The display shows icons that are related to the equipment installed on a particular spa model so this screen may change depending on the installation The navigation buttons are used to select an individual device The device that is chosen is highlighted with a white outline and the text under the icon changes to white Once a device is selected it can be controlled using the center Select Button Some devices like pumps may have more than one ON state so the icon will change to reflect the state that the equipment is in Below are some examples of 2 speed Pump indicators Jets Off Jets Low Jets High If the Spa has a Circ Pump a Circ Pump Icon will appear to indicate its activity but outside of Priming Mode the Circ Pump cannot be controlled directly NOTE The icon for the pump that is associated with the heater Circ or P1 Low will have a red glow in the center when the heater is running Jets 2 One Press Activation The Shortcut Screen requires no navigation Each button is fixed on a specific fuction and can be used as a very simple user interface for the spa Each button function is illustrated in the display and mapped according to the manufacturer s instructions BALBGA weter group Manufactured under
6. rupter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa hot tub and in line of sight from the equipment compartment CSA enclosure Type 2 Refer to Wiring Diagram inside the cover of the control enclosure Refer to Installation and Safety Instructions provided by the spa manufac turer Warning People with infectious diseases should not use a spa or hot tub Warning To avoid injury exercise care when entering or exiting the spa or hot tub Warning Do not use a spa or hot tub immediately following strenuous exercise Warning Prolonged immersion in a spa or hot tub may be injurious to your health Warning Maintain water chemistry in accordance with the Manufactur ers instructions Warning The equipment and controls shall be located not less than 1 5 meters horizontally from the spa or hot tub Warning GFCI or RCD Protection The Owner should test and reset the GFCI or RCD on a regular basis to verify its function Warning Shock Hazard No User Serviceable Parts Do not attempt service of this control system Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a licensed electrician and all ground ing connections must be properly installed CSA Compliance Conformit Caution Test the ground fault circuit interrupter before each use of the spa Read t
7. All material copyright of Balboa Water Group 40985_F 14 12 08 11 Information System Information The System Information Menu displays various settings and A Software ID SSID Back identification of the particular system As each item in the menu is highlighted the detail for that item is displayed at the bottom of the screen Software ID SSID Displays the software ID number for the System System Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setup Number Configuration Signature Displays the checksum for the system configuration file Heater Voltage Feature not used on CE rated systems Displays the operating voltage configured for the heater Heater Wattage as Configured in Software CE Systems Only Displays a heater kilowatt rating as programmed into the control system software 1 3 or 3 6 Heater Type Displays a heater type ID number Dip Switch Settings Displays a number that represents the DIP switch positions of S1 on the main circuit board Panel Version Displays a number of the software in the topside control panel BALBGA woter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied
8. NIH M 5 SH 2 00 1 0 1V3H HLIM dW d SH GOV ZV P gt NIH M SH L 00 LNOG voix 1531 IV 440 SGOW 1831 je 6v gaNSiSSV LON 8 P G3N9ISSY LON GANSISSV LON 4 V pel NO LS 11 5 440 LS MNVSHOLIMS 8111 ZL EL 6 5 54001386 NI 834018 03345 mysauasnassmn ee anaoat nat 8b Lb 401356 NI Z did 03345 1 81 rire 6 540136 NI Z 4 345 2 211115 840138 NI 033dS ANY Z dWnid Q33dS 91 5 540135 NI ASNA 8 3111146 HUM 434018 03345 1 ANY 03345 1 vL EL 8 9 2 540135 NI A INO 6 dWNd 03345 1 2 840136 03345 2 SI H30NVdX3 S3SS3LIA Z V 34WOd NOLLVIN3MWITV 3dWnd MH2S39 2 SNn980SH3AWOHISZL3N esr tdWnd 5 SEES Noor zanouo NOL 4482 18 NOK AS UN 8v sv er TO 1 sr ser HO ber SAN d NIV 41 sBuequeisaw Los om Aunxny 159 exnjeg eweueg epeuaig eweyeg 00944 8L Lb ZEEE 6 5 664135 NI eBejew NO 8 Lf OL err motte 5000288 V9LX A0EZXE SIZV4 I INIT 3NH L iqqerv 99 d92d4 ZAEZSOIM 2002559 210459 700559
9. Disinfection Disinfectant is the chemical that eliminates or neutralises the microorganisms bacteria algae fungi viruses present in the water Microorganisms are small microscopic organisms which cannot be detected with the naked eye and are continuously getting into the water through rain wind and the body of the bathers If they are not eliminated they pass from one person to the other through the water and may cause sickness infection Organic matter turns the water of the basin opaque and cloudy Most often as we are dealing with warm water basins bromine or active oxygen is used 4 Frothing Froth is the smaller bigger agglomeration of the bubbles and colloid contaminants found on the surface of the water It is mostly caused by the mixing of the dirt cosmetics body care lotions etc that soak out of the human skin and the chemicals It endangers the conservation of the aesthetic appearance and cleanliness of the water 5 Water analysers There are several different types of water analysers which are mostly used to measure chemical and disinfectant effect Chemical pH Disinfectant Br O3 Types Box containing tablets and graduated measuring glass Litmus paper indicators in a box Replacing underwater light Turn off thepower on the spa Remove plastic panel behind where the underwater light is situated There is a plug with two wires going into the back of the light Remove this plug by turning an
10. MUST DO EVERYTHING STATED IN THE SPA OWNERS MANUAL AND WARRANTY LETTER TO SAFEGUARD AND MAINTAIN THE SPA MANUFACTURER OF YOUR SPA Wellis Magyarorszag Kft Registered 2371 Dabas Manteleki ut hrsz 0417 Pf 7 Hungary CHeadquarters 2371 Dabas Manteleki ut hrsz 0417 Pf 7 Hungary AUTHORIZED DEALER OF YOUR SPA Company in charge of your spa tectae ee re ede Rae ie Oa nade Ie datant Ae SERVICE WORK The announcement date of damage Date of received goods parts for repair Date of the return of repaired goods parts Date of site service Improved error Mode of repair Failed component New deadline for the warranty The announcement date of damage Date of received goods parts for repair Date of the return of repaired goods parts Date of site service Improved error Mode of repair Failed component New deadline for the warranty The announcement date of damage Date of received goods parts for repair Date of the return of repaired goods parts Date of site service Improved error Mode of repair Failed component New deadline for the warranty The announcement date of damage Date of received goods parts for repair Date of the return of repaired goods parts Date of site service Improved error Mode of repair Failed component New deadline for the warranty SAFETY INSTRUCTIONS ATTENTION PLEASE READ C
11. TC Water Temperature is Unknown After the pump has been running for 1 minute the temperature will be displayed Possible freezing condition A potential freeze condition has been detected or the Aux Freeze Switch has closed All water devices are activated In some cases pumps may turn on and off and the heater may operate during Freeze Protection This is an operational message not an error indication The water is too hot M029 The system has detected a spa water temp of 110 F 43 3 C or more and spa functions are disabled System will auto reset when the spa water temp is below 108 F 42 2 C Check for extended pump operation or high ambient temp MOXX numbers are Message Codes See Page 13 BALE 9 IX This message can be reset from the topside panel water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 17 12 08 11 Heater Related Messages The water flow is low M016 There may not be enough water flow through the heater to carry the heat away from the heating element Heater start up will begin again after about 1 min See Flow Related Checks below The water flow has failed M017 There is not e
12. dWNd 03345 2 2111 5 840138 NI dWNd 03345 1 ONY 2 dWnd 3345 91 SE 54136 NI 8504 SNITNI 8 31 1745 ONY 03345 1 vL EL 8 9 2 540136 NI A1NO dWNd 03345 1 17 840135 dWNd 51 330NVdX3 48858310 Z V 3dWOd NOLLVIN3MWITV 3d Wd MH2S39 2 SNn9NOSH3AWOMNISZI3N ESF bf 5 dnouo NO 9f 2 dnO35 NO ddSZ 18 NO If 2 iz OL wosi OL wows Sion 39130 gv sv er TO v Lv sr ser HO ver STANVd 41 sBuaquajsaMw umm Anan sfuequajseM axnjag eweyeg 144 oe an ete eweyeg 81112111 6 5 6 540135 NI 5 eBejew 009d8 ir NO 334018 CFF OL Err a mawaa WZEXL AO ZXI SIZV3 1 3NI11 vozujqoy axnjag uenguuew iqqeiv 929 d92d4 ZAEZSOIM 20029459 210959 200959 3 Phase Line Connection NOLLYTIVISNI TVNIJ NOJN 330 01138 38 QINOHSSHHOLIMSe 7 680 Nd LIN 3ulW XZd8 2 G3NSISSV LON G3N9ISSV LON GANSISSV LON GANSISSV LON mu vt Ore rs Sundae Q3NOISSV LON 4393Y AHONWSM 136 38015 8 3108 39 4 1 12345 sv We v31ns 39viadWv 1719345 LV3H HLIM SdWNd SH 00 SdWhd SH aav LNOG LV3H HLIM SdWnd SHZ 00 V Be
13. it Light inoperative Light wiring or assembly is Replace light assembly faulty Power indicator Heater high limit Disconnect power for at least thirty blinking Enter spa thermostat tripped seconds to reset heater high limit If it will inoperative not reset Check for clogged filters if tripping continues call for service Ready indicator Temperature sensor Disconnect power for at feast thirty seconds blinking problem if blinking continues call for service TP800 and TP900 Series Control Panels Balboa Water Group Colossus Series User Interface and Programming Reference System Model BP2500 2600 Software Version 5 0 and later Panel Model TP900 Series TP800 Series Software Version 2 0 or later 1 9 or later BALBGA woter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 1 12 08 11 The Main Screen Spa Status Important information about spa operation can be seen quickly from the Main Screen The most important features including Set Temperature adjustment can be accessed from this screen The actual water temperature can be seen in large text and the desired or Set Temperature can be selected and a
14. of Balboa Water Group 40985_F 19 12 08 11 System Related Messages Program memory failure M022 At Power Up the system has failed the Program Checksum Test This indicates a problem with the firmware operation program and requires a service call The settings have been reset Persistent Memory Error M021 Contact your dealer or service organization if this message appears on more than one power up The clock has failed M020 Contact your dealer or service organization Configuration error Spa will not Start Up Contact your dealer or service organization GFCI test failed System Could Not Test the GFCI M036 North America Only May indicate an unsafe installation Contact your dealer or service organization A pump may be stuck on M034 Water may be overheated POWER DOWN THE SPA DO NOT ENTER THE WATER Contact your dealer or service organization Hot fault M035 A Pump Appears to have been Stuck ON when spa was last powered POWER DOWN THE SPA DO NOT ENTER THE WATER Contact your dealer or service organization MOXX numbers are Message Codes See Page 13 BALB 9 A This message can be reset from the topside panel water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and dome
15. when wet proper drainage is essential to prevent a build up of water around the spa When building a new room for the spa it is recommended that a floor drain is installed The humidity will naturally increase with the spa installed water may get into woodwork and produce dry rot mildew or other problems check for airborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area 2 0UTDOOR AND PATIO INSTALLATION It is important that you have solid foundation to support the new spa when you install it To be certain your deck or foundation can support your spa you must know the deck s maximum load capacity Consult a qualified building contractor or structural engineer To find the weight of your spa its contents and occupants please refer to the spa specification chart This weight per square foot must not exceed the structure s rated capacity otherwise serious structural damages could result If you install the spa outdoors we recommend a reinforced concrete pad at least four inches thick Don t forget to install some floor drains around your spa so that it can take the water away during and after the heavy rain INSTALLATION 1 Please read and study the OWNER S MANUAL carefully if possible please find the professional people to install and setup for first time 2 Remove the package and takes down the new spa on the prepared foundation
16. with sanitizer and maintain sanitizer level Allow free chlorine level to drop below 5ppm before spa use Adjust total alkalinity and or PH Use a metal deposit inhibitor Adjust total alkalinity and PH if scale requires removal drain the spa scrub off the scale refill the spa and balance the water Entire spais inoperative Spa does not heat jets and light operate Ready and power indicators are power indicators Power failure GFCI tripped heater high limit thermostat tripped Integrated pressure switch open Circulation pump thermal cut off tripped Check power source Reset GFCL call for service if will not reset Disconnect power for at least thirty seconds to reset heater high limit If it will not reset check for clogged filters If tripping continues call for service Check for cartridge filters Integrated pressure switch will reset when the flow of water through the heater has been restored Call for service if the heater trips frequently Check for cartridge filters or are looks in are blinking plumbing Disconnected power to the spa allow circulation pump to cool Circulation pump thermal cut off will reset when pump has cooled and power is reapplied Call for service if circulation pump thermal cut off trips frequently Spa water level too low Filters clogged Air Control closed Jet closed Jets weak or surging Add water Clean filters Open Air Controller Open the jet by adjust face of
17. 1 Adjusting Filtration Main Filtration Using the same navigation and adjustment as Setting the Time Filter Cycles are set using a start time and a duration Each setting can be adjusted in 15 minute increments The panel calculates the end time and displays it automatically Back Cancel Filter Cycle 2 Optional Filtration Filter Cycle 2 is OFF by default Simply navigate to the Filter Cycle 2 line by pressing the Right Navigation Button and when NO is highlighted press Up or Down to toggle Filter Cycle 2 on and off When Filter Cycle 2 is ON it can be adjusted in the same manner as Filter Cycle 1 by navigating to the right It is possible to overlap Filter Cycle 1 and Filter Cycle 2 which will shorten overall filtration by the overlap amount Circulation Pump Modes Some spas may be manufactured with Circ Pump settings that allow programming filtration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa manufacturer s documentation for any Circ Mode details Purge Cycles In order to maintain sanitary conditions as well as protect against freezing secondary water devices will purge water from their respective plumbing by running briefly at the beginning of each filter cycle If the Filter Cycle 1 duration is set for 24 hours enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is pro grammed to begin BALBOA water group
18. 3 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 18 12 08 11 Sensor Related Messages Sensors are out of sync M015 The temperature sensors MAY be out of sync by 2 F or 3 F Call for Service Sensors are out of sync Call for service M026 The temperature sensors ARE out of sync The fault above has been established for at least 1 hour Call for Service Sensor A Fault Senor B Fault Sensor A M031 Sensor B M032 A temperature sensor or sensor circuit has failed Call for Service Miscellaneous Messages Communications error The control panel is not receiving communication from the System Call for Service Test software installed The Control System is operating with test software Call for Service F or C is replaced by T The Control System is in Test Mode Call for Service MOXX numbers are Message Codes See Page 13 BALE 9 IX This message can be reset from the topside panel weter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright
19. AREFULLY AND FOLLOW THE INSTRUCTIONS AVOIDING THE RISK TO CHILDREN 1 4 In order to reduce the risk of injury to children do not allow children to use this spa alone unless they are carefully supervised at all the times In order to reducing the risk of injury to children lower water temperatures are recommended for young children Please test the water temperature with your hands before allowing children to enter into the spa and make sure It Is comfortable for children s usage Remember that wet surfaces can be slippery please reminding children to be careful enough when entering or exiting the spa Don t permit children to climb onto the spa cover AVOIDING THE RISK TO ADULT 1 6 In order to reducing the risk of injury to persons do not remove or lost any suction fittings Never operate spa if the suction fitting are broken or missing Remember that wet surfaces can be very slippery Take care of a danger of slipping and falling when entering or exiting the spa For the sake of health people with infectious diseases should not be allowed to use the spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components The use of drugs alcohol or medicine before or during spa use may lead to uncon sciousness with the possibility of drowning Persons using medicines should consult a physician before using spa some medicine may cause a user to become drowsy While other medici
20. CI and the spa will operate normally from that point You can verify a successful test by navigating to the above menu PASS should appear after a temp button is pressed from the GFCI screen Warning The end user must be trained to expect this one time test to occur and how to properly reset the If freezing conditions exist the GFCI or RCD should be reset immediately or spa damage could result CE Product CE registered systems do not have an RCD Test Feature due to the nature of the electrical service Some UL registered systems do not have the GFCI Test Feature activated The end user must be trained how to properly test and reset the RCD BALBGA weter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 16 12 08 11 General Messages Most messages and alerts will appear at the bottom of the normally used screens Several alerts and messages may be displayed in a sequence Some messages can be reset from the panel Messages that can be reset will appear with a right arrow at the end of the message This message Clean the filter can be selected by navigating to it at pressing the Select button
21. Mode In addition if the spa has a Circ Pump it can be activated by pressing the dedicated Light button during Priming Mode when using a TP800 Manually exit Priming Mode by pressing the Exit Button Jets 2 Jets 3 Priming the Pumps As soon as the Priming Mode screeen appears on the panel select the Jets 1 button once to start Pump 1 in low speed and then again to switch to high speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pumps to continue to run Turn off the pumps and repeat the process Note Turning the power off and back on again will initiate a new pump priming session Sometimes momentarily turning the pump off and on will help it to prime Do not do this more than 5 times If the pump s will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run without priming for more than 2 minutes Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4 5 minute priming mode Doing so may cause damage to the pump and cause the system to energize the heater and go into an overheat condition Exiting Priming Mode You can manually exit Priming Mode by navigating to the Back button on the Priming Mode Screen Note that if you do not manually exit
22. Wellis RoundLine USER MANUAL ACAPULCO deep in 3x2 HP hydromassage pumps Filter grid For 6 persons 40 pcs massage jets Hot air SILENT blower 0 3HP circulation pump UV C water desinfection Version 01 2014 www wellis eu Standard Specification Diameter Shell material Sitting places Watervolume Net weight Total number of jets Power requirement Air jets Hydromassage pump Hot air blower pump Water circulation pump UV C disinfecting lamp Chrondotherapy lighting 2400mm 6 3mm PU reinforced acrylic 6 persons 1470 250 kg 40 pcs 3 x 16A 400V optimum 1 x 32A 230V minimum 12 pcs 3 x 2 HP 230V 50Hz 1 300W 230V 50Hz 1 x 0 3 HP 230V 50Hz 1 1 lampe with 55 LEDs Exclusive multi point colour therapy lighting 12 x 1 LED Heating unit UV C water desinfection 1 5 drain Air inlet regulator BALBOA BP2100 control system Filter grid Leg structure Thermo cover 1 x 3 kW 230V 50Hz 1 1 pc 1 pc 1 set 1 set 1 WARRANTY LETTER Modeles as Distributor Retailer Date of buying Date of buying Signature Signature stamp stamp 2014 Wellis Spa Limited Warranty WARRANTY FOR EXPORT Warranty Limitations of Liability and Damages Company offers a limited warranty comprised of replacement of faulty parts and offers no reimbursement for labor of repairs outside any abnormal failure rates to be dete
23. aker is not permitted to be installed in the same place as the spa Required to install IEC RCCB system in spa s common surroundings Length of cable is 3 meters at the place of spa installed It is obligatory to observe all information details and requirements which are in the product s installation diagram regarding elelectricity demand and drain installation These information can be found in the user manual or able to download from www wellis eu If you didn t get the document from your dealer please contact export 2 wellis eu 9 If damage to the spa has resulted from debris in jets i e sand dirty calcium leaves etc 10 Warranty doesn t extend to the waste water manifold drain hose pillows filters bulbs and or pump sealings LIMITATIONS The Warranty expressions specified excludes any other implied or oral undertakings Purchasers also have current rights under statute which will be respected by Wellis Magyarorszag Kft After a period of 12 months for the purpose of assessing Wellis Magyarorszag Kft liability all aspects covered by this Warranty will be treated on a pro rata basis Wellis Magyarorszag Kft or its agents will not be liable for any incidental or consequential loss or injury Nor will Wellis Magyarorszag Kft be liable for costs associated with but not limited to building alterations or finishes and under no circumstances will be liable for greater expense than the amount paid for the product THE SPA OWNER
24. art of each filter cycle the water devices like blower mist device if these exist and other pumps will run briefly to purge the plumbing to maintain good water quality Freeze Protection If the temperature sensors within the heater detect a low enough temperature then the water devices automatically acti vate to provide freeze protection The water devices will run either continuously or periodically depending on conditions In colder climates an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch See your dealer for details Clean up Cycle optional When a pump or blower is turned on by a button press a clean up cycle begins 30 minutes after the pump or blower is turned off or times out The pump and the ozone generator will run for 30 minutes or more depending on the system On some systems you can change this setting See the Preferences section on page 14 BALBGA weter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 8 12 08 11 Tim
25. be impaired if the spa is located near hills or it is in a valley or simply outside the broadcasting range of the radio stations The position of the spa and radio may be out of phase with the bandwidth or the radio frequency External signal reception assistance may be required and is not part of this warranty 5 Wellis Magyarorsz g Kft shall not be liable for any incidental or consequential damages for breach of any expressed or implied warranty breach of contract negligence strict liability or any other legal theory related to this product All consequential expenses including loss of use damages or contingent liabilities arising out of any alleged deficiencies of the spa are specifically excluded from this warranty 6 Warranty coverage is only extended to the original buyer Spas purchased from anyone other than a current Wellis Spas Authorized Dealer are specifically excluded from any warranty coverage To obtain warranty service please notify your Wellis Spas Authorized Dealer in writing within 14 days of the problem with problem details original proof of purchase 7 The Authorized Dealer will repair or replace any component found defective under the terms of this warranty and permitted by Wellis Magyarorsz g Kft Travelling expenses may apply outside of every European cities 8 If the Authorized Dealer doesn t supply the customer with proper service please notify Wellis Magyarorsz g Kft by mail within 10 days of the pr
26. culate water every 1 2 hour using Pump 1 Low in order to maintain a constant water temperature heat as needed and refresh the temperature display This is known as polling REST Mode will only allow heating during programmed filter cycles Since polling does not occur the temperature display may not show a current temperature until the heater pump has been running for a minute or two While Pump 1 High can be turned on and off Pump 1 Low will run until set temperature is reached or 1 hour has passed Circulation Mode See Page 8 under Pumps for other circulation modes If the spa is configured for 24HR circulation the heater pump generally runs continuously Since the heater pump is always running the spa will maintain set temperature and heat as needed in Ready Mode without polling In Rest Mode the spa will only heat to set temperature during programmed filter times even though the water is being filtered constantly when in Circulation Mode Back Heat Mode Ready Invert Panel Normal Ready in Rest Mode READY REST appears in the display if the spa is in Rest Mode and the Jets 1 Button is pressed It is assumed that the spa is being used and will heat to set temperature While Pump 1 High can be turned on and off Pump 1 Low will run until set temperature is reached or 1 hour has passed After 1 hour the System will revert to Rest Mode This mode can also be reset by entering the Settings Menu and changing the Heat Mode
27. djusted Time of day Ozone operation and Filter Operation status is available along with other messages and alerts High Temperature Range vs Low Temperature Range is indicated in the upper right corner The Jets Icon in the center will spin on a TP900 if any pump is running and changes color when the heater is on The icon does not spin on a TP800 but still indicates pump and heater function A Lock icon is visible if the panel or settings are locked The Menu choices on the right can be selected and the screen will change to show more detailed controls or programming functions Water Temperature Temperature Range Desired Temperature Pump and Heat Status 1 02 High Range Set 104 F Spa 8 32 PM Shortcuts Ozone Settings Filter 1 Ready in Rest Mode Heating Messages Menus Lock Indicator BALBOA water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 2 12 08 11 The Main Screen Navigation Navigating the entire menu structure is done with the 5 buttons on the control panel When a text item changes to white during navigation that indicates the
28. e and any other chemicals or a chemical dispenser that may rest on the spa surface Some household cleaners can damage the spa shell or equipment and will void this warranty completely Use only products that are recommended for spas 3 If damage to the spa has resulted from an Act of God force majeure moving of the spa improper installation unstable power conditions customer negligence customer abuse weather and sunlight damage or damage caused in shipment 4 If damage to the spa has resulted from operation outside temperature exceed 45 C 5 If the spa has been subjected to any alterations after market product installations misuses abuses or if any repairs are attempted by anyone other than its authorised dealers 6 If damage to the spa has resulted from improper use of thermo cover 7 If damage to the spa has resulted from clogged dirty and or sclerosed filter The spa warranty will be void if the owner does not follow all the instructions in the owners manual regarding the proper use and care of the spa Warranty doesn t apply to filters 8 If damage to the spa has resulted from improper electrical installation voltage drop peak voltage and or operation is outside the pale of 10 voltage range Electrical conditions For electrical installation it is required to build a 30mA circuit breaker life safety relay which is just connected to the spa not allowed to connect any other devices This 30 mA circuit bre
29. e of Day Be sure to set the Time of Day Setting the time of day is important for determining filtration times and other background features Set Time will appear on the display if no time of day is set in the memory On the Settings Screen select the Time of Day line On the Time of Day screen simply navigate right and left to select the Hour Minutes AM PM and 12 24 Hour segments Use the Up and Down Buttons to make changes Saving Settings The Time of Day screen is a simple editable screen that illustrates a feature of the control that applies to all other editable screens as well When changes are made the icon to go Back changes to Save and a new icon for Cancel appears under the Save icon Navigating to the left will highlight the Save icon and navigating down from there will allow the user to cancel the pend ing change Pressing the Select button will save or cancel the changes and go back to the previous screen Cancel Note If power is interrupted to the system Time of Day will be maintained for several days BALBOA water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 9 12 08 1
30. ercise Warning Prolonged immersion in a spa or hot tub may be injurious to your health Warning Maintain water chemistry in accordance with the Manufacturers instructions Warning The equipment and controls shall be located not less than 1 5 meters horizontally from the spa or hot tub Warning GFCI or RCD Protection The Owner should test and reset the GFCI or RCD on a regular basis to verify its function Warning Shock Hazard No User Serviceable Parts Do not attempt service of this control system Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a licensed electrician and all grounding connections must be properly installed CSA Compliance Caution Test the ground fault circuit interrupter before each use of the spa Read the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device To ensure continued protection against shock hazard use only identical replacement parts when servicing nstall a suitably rated suction guard to match the maximum fl ow rate marked Warning Water temperature in excess of 38 C may be injurious to your health Disconnect the electrical power before servicing Warning Disco
31. ertissement Disconnect the electric power before servicing Keep access door closed Deconnecter du circuit d alimentation electrique avant l entretien Garder la porte fermer BALBGA woter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 12 08 11 Basic Installation and Configuration Guidelines Use minimum 6AWG copper conductors only Torque fi eld connections between 21 and 23 in 165 Readily accessible disconnecting means to be provided at time of installation Permanently connected power supply Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa hot tub and in line of sight from the equipment compartment CSA enclosure Type 2 Refer to Wiring Diagram inside the cover of the control enclosure Refer to Installation and Safety Instructions provided by the spa manufacturer Warning People with infectious diseases should not use a spa or hot tub Warning To avoid injury exercise care when entering or exiting the spa or hot tub Warning Do not use a spa or hot tub immediately following strenuous ex
32. for and pending All material copyright of Balboa Water Group 40985 F 15 12 08 11 Utilities GFCI Test Feature The Ground Fault Circuit Interrupter GFCI or Residual Current Detector RCD is an important safety device and is required equipment on a hot tub installation Back The GFCI Test Feature is not available on CE rated systems Used for verifying a proper installation Your spa may be equipped with a GFCI Protection feature If your spa has this feature enabled by the manufacturer the GFCI Trip Test must occur to allow proper spa function Within 1 to 7 days after startup the spa will trip the GFCI to test it The number of days is factory programmed The GFCI must be reset once it has tripped After passing the GFCI Trip Test any subsequent GFCI trips will indicate a ground fault or other unsafe condition and the power to the spa must be shut off until a service person can correct the problem Forcing the GFCI Trip Test North America Only The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu The GFCI should trip within several seconds and the spa should shut down If it does not shut down the power and manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly Verify the function of the GFCI with its own test button Restore power to the spa and repeat the GFCI Trip Test Once the GFCI is tripped by the test reset the GF
33. he instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated suction guard to match the maximum flow rate marked Warning Water temperature in excess of 38 C may be injurious to your health Disconnect the electrical power before servicing Attention Toujours verifier l efficacite du disjoncteur differentiel avant d utiliser differentiel avant d utiliser le bain Lire la notice technique Lorsque l appareillage est installe dans une fosse on doit assurer un drainage adequat Employer uniquement a l interieur d une cloture CSA Enclosure 3 Connecter uniquement a un circuit protege par un disjoncteur differen tiel de Class A e Afin d assurer une protection permanente contre le danger de shock electrique lors de l entretien employer seulement des pieces de rechange identiques les prises d aspiration doivent etre equipees de grilles convenant au debit maximal indique Avertissement Des temperatures de l eau superieures a 38 C peuvent presenter un danger pour la sante Deconnecter du circuit d alimentation electrique avante l entretien Warning Adv
34. ign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 13 12 08 11 Additional Settings Preferences The Preferences Menu allows the user to change certain parameters based 1 O Temp Display F on personal preference Back Temp Display Change the temperature between Fahrenheit and Celsius Time Display Change the clock between 12 hr and 24 hr display Reminders Turn the reminder messages like Clean Filter On or Off Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time Pump 1 will run after each use 0 4 hours are available Dolphin II and Dolphin III Applies to RF Dolphin only When set to 0 no addressing is used Use this setting for a Dolphin II or Dolphin III which is factory set for no address by default When set between 1 and 7 the number is the address See the Dolphin manual for details Color Pressing the Select Button when Color is highlighted will cycle through 5 background colors available in the control Language Change the language displayed on the panel BALBGA weter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending
35. ions for keeping the water of the massage basin clean are the removal of mechanical dirt and the blending of the chemicals in the water with continuous water recirculation In all our basins appliances comprising of a pump and a filter are used for this purpose The filter removes the dirt floating in the water or at the surface of the water Filters with paper or textile filter medium are used for the basins The dirt settled at the bottom of the basin is filtered out with the aid of the suction and stirring created by the massage pumps Don t leave the spa expose to the sun without water or the cover Exposure to direct sunlight can cause solar distress of the shell material Use and cover spa cover when spa is not in use whether it is empty or full Try to deep your spa away form rain snow if possible build a gazebo for your spa Don t attempt to open the electrical control box There are no user serviceable parts inside Drain clean and refill your spa with fresh water on a regular schedule Clean the filter cartridge at least once per month Have spa users bathe before entering the spa water showering without soap prior to enter the spa and using only the rinse cycle when laundering your bathing suit will help avoiding detergent and soap residue in spa water WN FILTER CARTRIDGE RMOVAL AND CLEANING You spa filter cartridge can become clogged with mineral particles of calcification from hard water Which may result in reduced water flo
36. item is selected for action Operating or changing a selected item is generally done with the center or Select button The only item that can be changed on the left side of the Main Screen is the Set Temperature Press the Left Arrow button to change the Set Temperature number to white The Set Temperature can then be adjusted with the up and down buttons Pressing the Select button or the Right Arrow button will save the new set temperature On the right side of the screen the menu selections can be selected with the Up and Down Buttons Use the Select Button to choose an item Selecting one of these items will change to a different screen with additional controls Spa Shortcuts Settings Messages At the bottom of the screen messages may appear at various times Some of these messages must be dismissed by the user see page 17 Press and Hold If an Up or Down button is pressed and held when the Set Temperature is selected the temperature will continue to change until the button is released or the Temperature Range limits are reached BALBOA water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 3 12 08 11
37. ne may affect heart blood pressure and circulation Pregnant women should consult a physician before using the spa AVOIDING THE RISK OF ELECTROCUTION 1 Test the ground fault circuit interrupters before use Must always to be connected 2 to circuit protected by a ground fault interrupt Must not bury the power cord a buried power cord may result in death or serious personal injury due to electrocution Replace a damaged cord immediately 3 Do not permit any electrical appliances such as a light telephone radio or television within 1 5m of a spa Failure to maintain a safe distance may result in death or serious pers on injury due to electrocuting if the appliance should fall into the spa 4 Install your spa in such a way that drainage is away from the electrical compartment and from all electrical components 5 Disconnect the spa from the power supply before servicing the electrical components NOTICE Your spa is a equipment with two three massage pumps that allow you to operate each half of the jet system separately or both valves simultaneously Do not connect power to an empty spa Otherwise the components such as controller heater circulation pump and other systems could be damaged INSTALLATION INSTRUCTIONS SITE PREPARATION 1 INDOOR BASEMENT INSTALLATION If you place your spa indoors be aware of some special requirements Water will accumulate around the spa so flooring materials must provide a good grip
38. ne year from the original date of delivery 1 year on LCD TV system The factory installed LCD TV systems are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 90 days on skimmer house Skimmer houses are subject to water chemistry variation and are warranted for ninety days from the original date of delivery NO warranty on filters spa pillows and skimmer house tops WARRANTY PERFORMANCE 1 This warranty does not cover cleaning or adjusting spa or for customer error in following correct procedures 2 Wellis Magyarorsz g Kft reserves the right to substitute a spa or component of equivalent value either new or factory reconditioned and any such repair or replacement shall assume as its warranty only the remaining portion of the warranty on the original product 3 Wellis Magyarorsz g Kft is not liable for any costs associated with in ground in deck or in home installations or removal Costs associated with installations other than standard residential portable spa use will be the sole responsibility of the spa owner The spa owner is responsible for any freight and or delivery and set up charges for a replacement spa 4 The radio reception is not covered under warranty due to the following The radio signal reception may be impaired by the positioning of the spa next to or near structures high power lines main power lines or metallic towers The signal reception may
39. nnect the electric power before servicing Keep access door closed Piping instructions of ACAPULCO spa 30mA safety relay is need to be installed 006 Uc XelN min 400 22400 min 400 BOOK Given sizes above are only information there may be variant sizes on the grounds of the spa s manufacturing technique 1 Phase Line Connection NOLLYTIVLSNI TVNI3 4 440 OL 13S 38 GINOHS 98 HILIMS 6980 1 GANSISSV LON GANSISSV LON GANSISSV LON Q3N9ISSV LON Q3NSISSV LON 1354 SONILLAS 34015 9 3103 1vI93dS 3103 39vii3dWv 19123485 LV3H SdW d SH 00 SdWnd SH t Gav LNOG LV3H HLIM SdWNd SHZ 00 SdWnd SHZ Gav 1V3H dWNd SH L GOV ZV dWnd SH 00 LNOQ vzcx ____ 440300W1S31 6v A A GaNOISSVION 8 aanoissv LON Q3NOISSVION 45 ee ae NO LS NNV8HOLIMS 340 LS MNVSHOLIMS 8L LE 214116 5 SdNLAS NI HIMO78 03345 1 T HRS s MT 8b LE 40136 NI Z 03345 1 81 vir 1N3W373213H 4 6 540135 NI Z
40. nough water flow through the heater to carry the heat away from the heating element and the heater has been disabled See Flow Related Checks below After the problem has been resolved you must press any button to reset and begin heater start up The heater may be dry M028 Possible dry heater or not enough water in the heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below The heater is dry M027 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must clear the message to restart heater start up See Flow Related Checks below The heater is too hot M030 One of the water temp sensors has detected 118 f 47 8 C in the heater and the spa is shut down You must clear the message when water is below 108 f 42 2 C See Flow Related Checks below Flow Related Checks Check for low water level suction flow restrictions closed valves trapped air too many closed jets and pump prime On some systems even when spa is shut down by an error condition some equipment may occasionally turn on to continue monitoring temperature or if freeze protection is needed MOXX numbers are Message Codes See Page 13 BALB 9 A This message can be reset from the topside panel water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 88
41. o maintain proper chemical balance and sanitary conditions Clean the cover May appear on a regular schedule 1 6 every 180 days Vinyl covers should be cleaned and conditioned for maximum life Treat the wood May appear on a regular schedule i e every 180 days Wood skirting and furniture should be cleaned and conditioned per the manufacturers instructions for maximum life Change the filter May appear on a regular schedule i e every 365 days Filters should be replaced occasionally to maintain proper spa function and sanitary conditions Reminder messages can be reset from the topside panel BAUB 9 A Additional messages may appear on specific systems water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 21 12 08 11 Warning Qualified Technician Required for Service and Installation Basic Installation and Configuration Guidelines Use minimum 6AWG copper conductors only Torque field connections between 21 and 23 in lbs Readily accessible disconnecting means to be provided at time of instal lation Permanently connected power supply Connect only to a circuit protected by a Class A Ground Fault Circuit Inter
42. o the spa are functioning properly connect spa plug to the power supply 3 Trail open and test Your controller with a factory s first setup already push the button of PUMP and AIR BLOWER to make jets run for some minutes to check the operation of the jet system and purge any remaining air from the heating system once the jet system fully operational priming of the spa is complete Check and make sure the air controller and jets are open Another possible main problem is AIR LOCK which can cause the jets to appear not work well or at all It is happened that when you are filling the spa up fairly rapidly air can get trapped in the pipes that go to the suction fittings and the jets The water level rises up past the openings in the spa The air becomes locked in the pipes and then when you go to start the spa pump it tries to suck in water but only air is in the pipes The pump cannot prime itself at that point so it just runs but does not pump any water Open the door of pump compartment loosen the quick disconnect fitting in front of the pump a little let some air get in and will break the air lock that has developed and then see some water start to come out re tighten the fitting turn the pump on it will surge for a few seconds and then start to pump properly If it still does not work Please contact a local spa professional to check it for you CLEANING GENERAL INFORMATION Water recirculation filtering The basic condit
43. oblem 9 Electrical connection All electrical connections are required to be done by a qualified electrician solely The spa has to be connected to separate current circuit equipped with suitable power switch and life safety relay Omission of these electrical conditions requirements entails immediate loss of the warranty 10 Water connection All water connections are required to be done by a qualified plumber solely If the spa is placed indoor make allowances for the following special requirements The water accumulates around the spa so the socket cover has to be in possession of a suitable drainage This arrangement hinders the water in collecting 11 Wellis Magyarorsz g Kft offers a limited warranty as described in the Warranty Letter 12 Warranty claim is enforceable with this warrant letter Irregular establishing of this warrant letter doesn t affect to the validity of warranty obligation If customer doesn t get this warrant letter from the Authorized Dealer it doesn t affect to the validity of warranty obligation SPA WARRANTY COVERAGE WILL BE VOID UNDER THE FOLLOWING CONDITIONS 1 If damages caused by inefficient maintance of water and or chemical dosage Terms of water hardness limits between 6 10 German degrees 2 If the spa surface or equipment has been damaged or discolored as a result of improper water chemistry maintenance including sanitizers such as trichlor type chlorine calcium hypochlorite sodium hypochlorit
44. ode is exited manually If spa service will require more than an hour it may be best to simply shut down power to the spa Drain Mode Some spas have a special feature that allows Pump 1 to be employed when draining the water When available this feature is a component of Hold Mode Utilities The Utilities Menu contains the following A B Temps When this is set to On the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater Demo Mode Demo Mode is not always enabled so it may not appear This is designed to operate several devices in a sequence in order to demonstrate the various features of a particular hot tub Fault Log The Fault Log is a record of the last 24 faults that can be uv reviewed by a service tech cwm aci GFCI Test Feature not available on CE rated systems GFCI Test is not always enabled so it may not appear This screen allows the GFCI to be tested manually from the panel and can be used to reset the automatic test feature If the GFCI Test Feature is reset the device will trip within 7 days See Page 16 M036 is a Message Code Codes like this will be seen in the Fault Log IN B3 AN weter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both fore
45. one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 4 12 08 11 The Settings Screen Pressing a Button When instructions are given to press a button any of the following can be done Navigate to the desired item on any Screen When the desired item is highlighted press the Select Button Press the button for that device while on the Shortcuts Screen if the device is one of the 4 functions available Programming Etc The Settings Screen is where all programming and other spa behaviors are controlled This screen has several features that can be acted on directly These features include Temp Range Heat Mode and Invert Panel When one of these items is highlighted the Select Button is used to toggle between two settings All other menu items with an arrow pointing to the right go to another level in the menu Press and Hold If an Up or Down button is pressed and held when an item in a Menu List is highlighted the list can be scrolled quickly from top to bottom The scroll bar on the right side of the screen indicates the relative position of the highlighted item in the list Temp Range High Back Dual Temperature Ranges High vs Low
46. polling and then to heat to the set temperature if needed When the low speed turns on automatically it cannot be deactivated from the panel however the high speed may be started Circulation Pump Modes If the system is equipped with a circ pump it will be configured to work in one of three different ways 1 The circ pump operates continuously 24 hours with the exception of turning off for 30 minutes at a time when the water temperature reaches 3 F 1 5 C above the set temperature most likely to happen in very hot climates 2 The circ pump stays on continuously regardless of water temperature 3 A programmable circ pump will come on when the system is checking temperature polling during filter cycles during freeze conditions or when another pump is on The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the field Other device options may be available like Blower Light Mist etc Filtration and Ozone On non circ systems Pump 1 low and the ozone generator will run during filtration On circ systems the ozone will gener ally run with the circ pump but can be limited to filtration cycles The system is factory programmed with one filter cycle that will run in the evening assuming the time of day is properly set when energy rates are often lower The filter time and duration are programmable See page 10 A second filter cycle can be enabled as needed At the st
47. r patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 11 12 08 11 Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings allows Jets and other features to be used but the Set Temperature and other programmed settings cannot be adjusted Settings Lock allows access to a reduced selection of menu items These include Set Temperature Invert Lock Utilities Information and Fault Log They can be seen but not changed or edited Settings OFF Back Unlocking Unlock Bak Panel An Unlock Sequence using the navigation buttons can be used from the Lock Screen The Unlock Sequence is the same for both Panel Lock and Settings Lock BALBOA water group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 12 12 08 11 Additional Settings Hold Mode M037 Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filter Hold Mode will last for 1 hour unless the m
48. rmined by both parties 5 year on spa shell Wellis warrants the structure of the Pool Shell against defects in workmanship and material for a period of 5 years subject to the limitations and conditions listed in this Warranty 3 years on spa shell surface The acrylic spa shell is warranted against cracking blistering or delaminating due to defects in materials or workmanship for three years from the original date of delivery 2 years on spa plumbing Spa fittings and plumbing are warranted against leaks due to defects in materials or workmanship for two years from the original date of delivery There is no labor coverage on internal jet parts replacement cleaning or adjusting 2 years on standard and optional spa equipment Balboa Control Systems Jet Pump s Laing Circulation Pump Heater WiFi modul IR receiver The spa equipment systems are warranted against failure due to defects in materials or workmanship for two years from the date of delivery Fuses bulbs and seals are not covered 2 year on Pulsar hydrotherapy system The factory installed Pulsal hydrotherapy systems are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 2 year on spa cabinets skirts The factory installed spa cabinets skirts are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 2 year on ozone generator The ozone generator i
49. s warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 2 year on audio system components The factory installed audio components i e power supply speakers wires etc are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery There is no in field labor service on these items 2 year on LED lights The factory installed LED lights are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 2 year on UV C sanitizer lamp The factory installed UV C sanitizer lamps are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 2 year on ISIS Genesis disinfection system The factory installed ISIS Genesis disinfection systems are warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 1 year on blower The blower is warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 1 year on thermo cover The thermo cover is warranted against failure due to defects in materials or workmanship for one year from the original date of delivery 1 year on Wellis Spa Umbrella The factory installed Wellis Soa Umbrellas are warranted against failure due to defects in materials or workmanship for o
50. stic applied for and pending All material copyright of Balboa Water Group 40985_F 20 12 08 11 Reminder Messages General maintenance helps Reminder Messages can be suppressed by using the Preferences Menu See Page 14 Reminder Messages can be chosen individually by the Manufacturer They may be disabled entirely or there may be a limited number of reminders on a specific model The frequency of each reminder i e 7 days can be specified by the Manufacturer Check the pH May appear on a regular schedule i e every 7 days Check pH with a test kit and adjust pH with the appropriate chemicals Check the sanitizer May appear on a regular schedule i e every 7 days Check sanitizer level and other water chemistry with a test kit and adjust with the appropriate chemicals Clean the filter May appear on a regular schedule i e every 30 days Clean the filter media as instructed by the manufacturer See HOLD on page 13 Test the GFCI or RCD May appear on a regular schedule i e every 30 days The GFCI or RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function Change the water May appear on a regular schedule i e every 90 days Change the water in the spa on regular basis t
51. the priming mode as described above the priming mode will be automatically terminated after 4 5 min utes Be sure that the pump s have been primed by this time Once the system has exited Priming Mode the top side panel will display the Main Screen but the display will not show the temperature yet as shown below This is because the system requires approximately 1 minute of water flowing through the heater to determine the water temperature and display it BALBGA 019 is a Message Code See Fault Log on Page 13 weter group Manufactured under one or more of these patents U S Patents 5332944 5361215 5550753 5559720 5 883 459 6253227 6282370 6590188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group 40985_F 7 12 08 11 Spa Behavior Pumps On the Spa Screen select a Jets button once to turn the pump on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a time out period The pump 1 low speed will time out after 30 min utes The high speed will time out after 15 minutes On non circ systems the low speed of pump 1 runs when the blower or any other pump is on If the spa is in Ready Mode See page 6 Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa temperature
52. ticlockwise Replace faulty light globe with a new one Replace parts and put the plastic panel back on Sy ie eS TROUBLESHOOTING Cloudy Water Dirty filters Improper sanitization Suspended particles organic matter Overused or water Excessive organics in water Improper sanitization Low PH Clean filters Shock spa with sanitizer Add sanitizer Adjust PH and or alkalinity to recommended range Run jet pump s and clean filters Drain and refill the spa Shock spa with sanitizer Add sanitizer Adjust PH refill the spa Chlorine Odor Chloramines level too high Shock spa with sanitizer low PH Adjust PH to recommended range Bacteria or algae growth Organic buildup scum ring around spa Algae Growth Eye limitation Build up of oils and dirt High PH Low sanitizer level Low PH Low sanitizer level Skin imitation Rash Unsanitary water Free chlorine level above 5ppm Total alkalinity and or PH too low high iron or copper in source water High calcium content in water total alkalinity and PH too high Shock spa with sanitizer id problem is visible or persistent drain clean and refill the spa Wipe off scum with clean rag if severe Drain the spa Use aspa surface and the cleaner to remove the scum and refill the spa Shock spa with sanitizer and adjust PH Shock spa with sanitizer and maintain sanitizer level Ajust PH Shock spa with sanitizer and maintain sanitizer level Shock spa
53. w We recommended cleaning you filter cartridge every month 1 Remove filter lid 2 Unscrew filter cartridge 3 Clean with high pressure nozzle to remove all debris clinging to the filter 4 Soak filter in warm water and Wellis Alga Sokk to remove all body oils and grime Never use chlorine to clean the filter If you use textile filter you can wash it int he washing machine too The chemical equilibrium of the water The water of the whirlpool will be clean and clear if its chemical components are in equilibrium 1 pH values The first important indicator is the pH value of the water pH is measured in a scale between 0 14 where 7 is the neutral value Below this level the water is acid above it alkaline The pH value of the human eye is around 7 5 below 7 2 and above 7 8 the water will sting the eyes of the bather Experiences have shown that most problems are caused by a too high pH value An improper value reduces the effect of the disinfectant 2 Water hardness Water hardness is determined by the quantity of calcium and magnesium salts dissolved in the water Hard waters contain too much of these dissolved salts and thus left alone scale will form Scales can cause significant damage both to the walls of the basin to the piping filter and to the heating and engineering units In Hungary waters are medium hard Water hardness cannot be reduced by the addition of chemicals but the formation of scales can be prevented 3