Home

0312-7201-00(135986_135987_135988)_V5.qxd:_

image

Contents

1. PEAK CEILING 500mm 1 Figure 2B NOT IN THIS AREA 1000mm ANYWHERE IN THIS AREA DEAD AIR Smoke alarm should be located between 500mm and 1500mm of the highest point DO NOT INSTALL SLOPED CEILING 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5 23 PM 3 Installation Instructions To minimise nuisance alarms avoid these locations Do not install within 0 9m of the following The door to a kitchen or a bathroom that contains a tub or shower forced air supply ducts used for heating or cool ing ceiling or whole house ventilating fans or other high air flow areas Areas where curtains or other objects will block the sensor Smoke must be able to reach the sensor to accurately detect conditions Install at least 30cm away from fluorescent lights Keep out of insect infested areas Avoid excessively dusty dirty or greasy areas D Do not install in areas where the temperature is colder than 5 C or hotter than 45 C Do not install in areas where the relative humidity RH is greater than 85 Avoid placing smoke alarms in kitchen areas If a kitchen alarm is desired it should have an alarm silencer feature or be a photoelectric type x Do not place in the garage Avoid dead air spaces such as the peak of an A frame ceiling Dead Air at the top may prevent smoke from reaching the alarm in time to provide early warning Refer to Figure 2A and 2B
2. N B Smoke alarms are not to be used with detector guards unless the combination alarm and guard has been evaluated and found suitable for that purpose MOBILE HOME INSTALLATION For Well Insulated Mobile Homes Install smoke alarms as recommended on the previous pages In mobile homes that are not well insulated extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling For Poorly Insulated Mobile Homes Install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 10cm and a maximum of 30cm below the ceiling Figure 2A For minimum protection install at least one alarm close to the bedrooms For additional protection see Figure 1A A WARNING TEST YOUR SMOKE ALARM OPERATION AFTER CARAVAN OR MOBILE HOME VEHICLE HAS BEEN IN STORAGE BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM Installation Instructions ATTACHING MOUNTING PLATE Ribs 2 gt OPTION 1 Easy Mount Drywall Only 1 Choose a mounting location wall or ceiling and drill a 3 16 diameter hole at least 1 2 deep 2 Insert the provided screw through the mounting plate aligning the ribs on the screw with the slots on the mounting plate 3 Tighten the screw mounting plate to wal
3. entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Exclusions Subject to non excludable laws this warranty does not cover normal wear and tear to the product or parts batteries or other consumables included with this product excluding sealed non replaceable battery models damage to the product caused by accidents misuse abuse lack of reasonable care tampering or repair by a person not authorised by Chubb any product that has not been installed operated or maintained in accordance with the manual or operating instructions provided with the product any damage caused by improper power input or improper cable connection any indirect or special loss or damage of any kind 23 PM 0312 7201 00 135986_135987 den V5 qxd 2013 10 24 5123 PM WARRANTY amp CONTACT DETAILS To make a claim If a defect in the product appears within the time frame stated you are entitled to submit a warranty claim by returning your product to the address shown below Please contact Chubb on the telephone numbers provided below Monday to Friday during 9 00AM 5 00PM When returning the product please ensure it is properly packaged so that no damage occurs during tran sit Any postage and packaging expenses required to return the product to Chubb will be at your cost Please provide the original or a copy of the proof of purchase Also please make sure
4. long beeps repeating every 1 5 seconds The smoke alarm takes precedence when both smoke are present Alert small children in the home as well as anyone else that might have difficulty recognizing the importance of the alarm sounding or that might have difficulty leav ing the area without help Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables When leaving don t open any inside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in fthe escape route requires you to go through smoke stay close to the floor and crawl under the smoke where the air is clearer Breathe shallowly through a cloth wet if possible Once outside go to your selected meeting place and make sure everyone is there Call the fire brigade 000 AUS or 111 NZ from your neighbour s home or a phone box not from yours Don t return to your home until the fire officials say that it is all right to do so 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM ZA WARNING Please read carefully and thoroughly Australian Standard AS 1670 6 states the purpose of installing smoke alarms is to provide early warning of a potenti
5. 0312 7201 00 135986_135987 988 _V5 qxd 2013 10 24 5123 PM 135986 Worry Free Living Area Photoelectric Smoke Alarm QUELL 135987 Worry Free Bedroom Photoelectric Smoke Alarm 135988 Worry Free Hallway Photoelectric Smoke Alarm User Manual Thank you for purchasing this Quell Worry Free smoke alarm This model is battery operated and features a non replaceable sealed in battery and SMART HUSH Control to temporarily silence nuisance alarms Important Please take a few minutes to thoroughly read this user manual which should be saved for future reference and passed on to any subsequent owner Your Quell smoke alarm was designed specifically for use in a residential environment It is not designed for use in a recreational vehicle RV or boat or in commercial or industrial premises For questions concerning this alarm please call Customer Service on 1800 654 435 We suggest that you write down the following information for your ease of reference This information will be required by Customer Service to provide you with assistance Smoke Alarm Model Number located on back of alarm Manufacture Date located on back of alarm It is recommended that this alarm be replaced ten years from the date of manufacture Quell is a registered trademark of Chubb Fire amp Security Pty Ltd Copyright 2012 Chubb Fire amp Security Pty Ltd All rights reserved P N 135986 Model P3010L 135987 Model P3010B 135988 Mod
6. ace If hot or you see smoke seeping through cracks don t open that door Instead use your alternative exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in Stay close to the floor if the air is smoky Breathe shallowly through a cloth wet if possible Once outside go to your selected meeting place and make sure everyone is there Call the fire brigade on 000 AUS or 111 NZ from your neighbour s home or a phone box not from yours Don t return to your home until the fire officials say that it is all right to do so There are situations where a smoke alarm may not effective to protect against fire For instance a smoking in bed b leaving children unsupervised cleaning with flammable liquids such as gasoline d fires where the victim is intimate with a flaming initiated fire for example when a person s clothes catch fire while cooking incendiary fires where the fire grows so rapidly that an occupant s egress is blocked even with proper ly located detectors Installation Date Alarm Model s Installer Landlord Tel Chubb Fire amp Security Pty Limited ABN 47 000 067 541 A UTC Climate Controls amp Security Company 149 155 Milton Street Ashfield NSW 2131 Australia www quell com au Chubb New Zealand Limited A UTC Climate Controls amp Security Company u 3 Fisher Crescent Mt Wellington CEES Auck
7. alarm powers this unit no battery installation or replacement is necessary for the life of the alarm IMPORTANT Constant exposure to high or low humidity may reduce battery life A WARNING DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON Do not try to repair the smoke alarm yourself No serviceable parts included Low battery This alarm is equipped with a low battery monitor circuit which will cause the alarm to produce a single chirp approximately every 60 seconds and blink the Red LED every 30 seconds for a minimum of seven 7 days should the battery become low THE UNIT MUST BE DEACTIVATED see Deactivation of Alarm section and replaced within 7 days of the first occurrence of the Low Battery Warning to provide continuous alarm protection 8 DEACTIVATION OF ALARM A N WARNING a Deactivation of the alarm is permanent Once the alarm has been deactivated it cannot be reactivated b Once deactivated the alarm will NO LONGER DETECT SMOKE c Once the alarm is deactivated the battery will be depleted and the alarm will no longer function d Once the alarm has been deactivated it cannot be mounted onto the mounting plate or reactivated WARNING Failure to turn off alarm as instructed prior to disposal may create potential for lithium battery related fire or hazard TO DEACTIVATE THE ALARM Remove the alarm from the mounting plate by rotating it in the direction indicated by the arrows on the cover of the ala
8. ally life threatening condition and provide the maximum possible exit time Smoke alarms have sensing limitations lonisation sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smouldering fires sooner than ionisation alarms Home fires develop in different ways and are often unpredictable For maximum protection both ionisa tion and photoelectric alarms should be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly AC powered alarms without battery backup will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor If the alarm is located outside the bedroom or on a different floor it may not wake up a sound sleeper The use of alcohol or drugs may also impair one s ability to hear the smoke alarm For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Although smoke alarms can help save lives by
9. arm is now activated After installation activation test your alarm as described in Operation and Testing section AN Warning Failure to properly install and activate this alarm will prevent proper operation of this alarm and will prevent its response to fire hazards Quell amp Worry Free Bedroom smoke alarm model P3010B 135987 will issue a voice prompt at activation asking the user to press the test button 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM 4 OPERATION AND TESTING OPERATION The alarm is operating once it is activated and testing is complete When products of combustion are sensed is detected the unit sounds a loud 85db pulsating alarm until the air is cleared A Warning Due to the loudness 85 decibels of the alarm always stand an arm s length about 2 5 feet away from the unit or use ear protection when testing TESTING TTESTING Test your alarm by pressing the test button until the unit chirps then release the test button The unit will then emit 2 sets of three slow beeps Quell Worry Free Bedroom smoke alarm model P3010B 135987 will also issue a voice prompt stating Fire Fire Quell Worry Free Hallway smoke alarm model P3010H 135988 will briefly illuminate the amber safety light The alarm will sound if the electronic circuitry horn and battery are working If the alarm does not sound the unit must be replaced Weekly testing is require
10. d to ensure proper operation Erratic or low volume sound or no sound coming from your alarm may indicate a defective alarm and it should be returned for service See deactivation section to determine how to prepare the unit for shipment or disposal A Warning DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a structure fire The following table describes the visual and audible alarm conditions the unit may encounter and illustrates how the unit will indicate normal standby alarm and error conditions 5 Alarm Visual and Audible Indicators The following tables describes the visual and audible alarm conditions the unit may report and illustrates how the unit will indicate normal standby alarm and error conditions 0312 7201 00 135986_135987 988 _V5 qxd 2013 10 24 Visual Audible Indications Indications Smoke or Fire Living Area 3 blinks synchronized with 3 long beeps repeating detected Model P3010L audible alarm Part No 135986 Bedroom with Voice 3 blinks synchronized with 3 long beeps repeating with Model P3010B audible alarm voice Fire Fire announced Part No 135987 Hallway with Emergency 3 blinks synchronized with 3 long beeps repeating Safety Light audible alarm amp amber light Model P3010H illuminated Part No 135988 If you require further information please contact Service on 1800 654 435 or visit our website at www q
11. e in the End of Life Hush mode the alarm will still detect Smoke The End of Life signal can be reset a maximum of 10 times for a total of 30 days After 10 resets the end of life signal can no longer be silenced and the alarm must be replaced immediately 5 23 PM 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM 6 NUISANCE ALARMS This smoke alarm is designed to minimize nuisance alarms Cigarette smoke will not normally cause the unit to alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if it is located too close to a cooking appliance Large quantities of combustible particles are generated from spills or when frying Using the fan on a range hood which vents to the outside non re circulating type will also help remove these combustible products from the kitchen If the alarm does sound the smoke alarm pattern of 3 long beeps check for fires first If a fire is discovered evacuate the occupants and call the fire department If no fire is present check to see if one of the reasons listed in To minimise nuisance alarms avoid these locations may have caused the alarm SMART HUSH CONTROL The SMART HUSH feature has the capability of temporarily desensitizing the alarm circuit for approximately 10 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm is desensitized by pu
12. eiling locate it at a minimum of 30cm from the side wall Figure 2A For sloped peaked or cathedral ceilings the alarm should be placed between 500mm and 1500mm from the highest point of the ceiling Figure 2B Smoke alarms in rooms with ceiling slopes greater than 1m in 8m horizontally should be located on the high side of the room Figure 2B For Wall Mounting When mounting the alarm on the wall use an interior wall with the top edge of the alarm at a minimum of 10cm and a maximum of 30cm below the ceiling Figure 2A 0312 7201 00 135986_135987 988 _V5 qxd 2013 10 24 Installation DINING BEDROOM HALL BEDROOM LIVING ROOM A Smoke Alarms for Minimum Protection Smoke Alarms for Additional Protection A lonisation Type Smoke Alarm with Alarm Silencer Hush or Photoelectric Type SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN FIGURE 1A FIGURE 1B MASTER BEDROOM FIRE EXTINGUISHERS 9 osi FAMILY ROOM e SMOKE ALARMS WORKSHOP FIGURE 1C TOTAL HOME PROTECTION Wm FIRE BLANKET 5 23 PM 0312 7201 00 135986_135987 den V5 qxd 2013 10 24 5123 PM Installation 30 cm 12 in CEILING li MINIMUM j D X Dap NS BEST DO NOT INSTALL PLACEMENT gt 13 5 ACCEPTABLE PLACEMENT go We SIDE WALL 500mm NOT IN THIS AREA 1000mm ANYWHERE IN THIS AREA a DO NOT INSTALL
13. el P3010H 0312 7201 00 0312 7201 00 135986_135987 dem V5 qxd 2013 10 24 5123 PM CONTENTS 1 WHAT TO DO WHEN THE ALARM SOUNDS SMOKE ALARM ACTIVATION 2 LIMITATIONS OF SMOKE ALARMS 3 INSTALLATION INSTRUCTIONS 4 OPERATION AND TESTING 5 VISUAL AND AUDIBLE INDICATIONS 6 MINIMISE NUISANCE ALARMS 7 BATTERY 8 DEACTIVATION OF ALARM 9 CLEANING 10 GOOD SAFETY HABITS 11 SERVICE 12 WARRANTY This alarm detects products of combustion using photo electric technology This alarm is acceptable for use in all residential applications where smoke alarms are required After ten 10 years of cumulative power up this unit will chirp two times every 30 seconds This is an operational end of life feature which will indicate that it is time to replace the alarm To help identify the date to replace the unit a label has been affixed to the side of the alarm Write the Replace by date 10 years from initial power up in permanent marker on the label prior to installing the unit Product Features and Specifications Temperature Operating Range 5 C to 45 C Humidity Operating range up to 85 non condensing Audible Alarm 85 dB at 3 metres 9 3 4 0 5 KHz pulsing alarm Smoke Sensor Photoelectric 0312 7201 00 135986_135987 den V5 qxd 2013 10 24 5123 PM 1 WHAT TO DO WHEN THE ALARM SOUNDS SMOKE ALARM ACTIVATION Smoke alarm pattern is three
14. he kitchen basement and garage Know how to use a fire extinguisher prior to an emergency e Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound or to those who may be incapable of safely evacu ating the area unassisted Make a floor plan indicating all doors and windows and at least two escape routes from each room Second storey windows may need a rope or chain ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of a fire Determine a place outside your home where you can meet if a fire occurs Familiarise everyone with the sound of the alarm and train them to leave your home when they hear it Practice a fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all becupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do What to do when the Alarm Sounds Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or pick ing up valuables In leaving don t open any inside door without first feeling its surf
15. l or ceiling until mounting plate is snug against surface DO NOT over tighten Mounting Option 1 OPTION 2 Mounting on Other Surfaces 1 Choose a mounting location wall or ceiling and using the mounting plate provided as a template mark three hole locations 2 Install the three provided screws through the mounting plate and tighten DO NOT over tighten screws If mounting in plasterboard or similar surface drill 3 16 holes and use the plastic anchors provided Anchors are not required for mounting on hard surfaces such as wood ATTACHING AND ACTIVATING THE ALARM This model is equipped with a feature that automatically activates the alarm when the alarm is attached to the mounting plate for the first time Once activated the 4 battery will supply power to the alarm for the life of the d Mounting alarm 10 years under normal conditions Option 2 Align the alarm with the mounting plate and rotate clockwise right approximately 45 until the unit stops and clicks into place DO NOT over tighten If unit needs to be re aligned rotate the alarm counter clockwise remove and rotate to desired alignment NOTE The alarm will mount to the plate in three 3 positions every 120 degrees You will know power has been supplied when alarm briefly chirps Unit will remain on until unit is disabled by the user at alarm s end of life Do not over tighten the alarm as damage to alarm or mounting surface may occur The al
16. land New Zealand www chubb co nz 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM 11 SERVICE During the specified warranty period Chubb Fire amp Security Pty Ltd will repair or replace at its discretion any defective Quell Alarms that are returned in a postage paid package to the following address Chubb Fire amp Security Pty Ltd Quell Warranty Returns 149 155 Milton Street Ashfield NSW 2131 Please include your name address and phone number along with a brief description of what is wrong with the unit For further assistance please call our toll free Customer Service at 1800 654 435 Damage from neglect abuse or failure to adhere to any of the enclosed instructions will result in termination of the warranty and the unit will not be replaced or repaired This User Manual and the products described herein are copyrighted with all rights reserved Under these copyright laws no part of this User Manual may be copied for use without the written consent of Chubb If you require further information please contact Customer Service at 1800 654 435 or write to us at Chubb Fire amp Security Pty Ltd 149 155 Milton Street Ashfield NSW 2131 Website www quell com au 0312 7201 00 135986_135987 den V5 qxd 2013 10 24 5 12 WARRANTY amp CONTACT DETAILS Chubb CIT TEN YEAR LIMITED WARRANTY Warranty Chubb warrants to the original consumer purchaser that each new smoke alarm will be free fro
17. m defects in materials and workmanship under normal use for a period of 10 years from the date of purchase To the extent permitted by law Chubb agrees to repair or replace at our discretion any defective product on presentation of the proof of purchase Australia warranty claims Where the goods are offered for sale in Australia the benefits to the consumer given by this warranty are in addition to other rights and remedies of the consumer under the Australian Consumer Law and other applicable laws relating to the goods Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replace ment or refund for a major failure and compensation for any other reason ably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure New Zealand warranty claims Where the goods are offered for sale in New Zealand the benefits to the con sumer given by this warranty are in addition to other rights and remedies of the consumer under relevant New Zealand consumer protection laws and other applicable laws relating to the goods Our goods come with guarantees that cannot be excluded under relevant New Zealand consumer protection laws You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also
18. providing an early warning of a fire they are not a substitute for an insurance policy Home owners landlords and ten ants should have adequate insurance to protect their lives and property There are situations where a smoke alarm may not be effective enough to protect against fire For instance a smoking in bed b leaving children home alone C cleaning with flammable liquids such as gasoline IMPORTANT This alarm is not designed to alert hearing impaired individuals 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM 2 LIMITATIONS OF SMOKE ALARMS A Additional Information Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows x In all sleeping rooms with the exception Smoke alarms shall not be required in sleeping rooms in existing one and two family dwelling units Outside of each separate sleeping area immediate vicinity of the sleeping rooms On each level of the dwelling unit including basements exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are more smoke alarms desirable The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this rea
19. rm Pressing the white small button will turn off alarm This will deactivate the alarm stop the low battery chirp and render the alarm safe for disposal by draining the battery 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM 9 CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR You can clean the interior of your alarm sensing chamber by using compressed air or a vacuum cleaner hose and blowing or vacuuming through the openings around the perimeter of the alarm The outside of the alarm can be wiped with a damp cloth Use only water to dampen the cloth use of detergents or cleaners could damage the alarm After cleaning test your alarm by using the test button If cleaning does not restore the alarm to normal operation the alarm should be replaced Never use detergent or other solvents to clean the unit Avoid spraying air freshener hair spray or other aerosols near the alarm Do not paint the unit Paint will seal the vents and interfere with the sensor s ability to detect smoke Never attempt to disassemble the unit or clean inside This action will void your warranty 10 GOOD SAFETY HABITS 0312 7201 00 135986_135987 988 _V5 qxd 2013 10 24 5123 PM C Detach and display next to your Consumer Unit Fuse Box Good Safety Habits Develop and practice a plan of escape Install and maintain Fire extinguishers on every level of the home and in t
20. shing the Test Hush button on the smoke alarm cover If the smoke is not too dense the alarm will silence immediately and the red LED blinks every 10 seconds This indicates that the alarm is in a temporarily desensitized condition Quell Worry Free Bedroom smoke alarm model P3010B 135987 will issue a voice prompt stating Hush Mode Activated Quell Worry Free Hallway smoke alarm model P3010H 135988 will turn off the amber safety light The smoke alarm will automatically reset after approximately 10 minutes and sound the alarm if particles of combustion are still present The SMART HUSH feature can be used repeatedly until the air has been cleared of the condition causing the alarm Pushing the Test Hush button on the alarm will end the temporarily desensitized period Quell Worry Free Bedroom smoke alarm model P3010B 135987 will issue a voice prompt stating Hush Mode Cancelled after the Test Hush button has been pressed If the smoke is not too dense after ten minutes the alarm will return to normal operation NOTE Dense smoke will override the SMART HUSH feature and sound a continuous alarm CAUTION Before using the alarm SMART HUSH feature identify the source of the smoke and be certain safe conditions exist 0312 7201 00 135986_135987 dem V5 qxd 2013 10 24 5123 PM 7 BATTERY BATTERY ACTIVATION AND DEACTIVATION NOTE One Lithium lon battery permanently sealed inside the
21. son it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not protected by the required smoke alarms The installation of the smoke alarms in the kitchen attic finished or unfinished or garage is normally not recommended as these locations occasionally experience conditions that can result in nuisance alarms 0312 7201 00 135986_135987 ee V5 qxd 2013 10 24 5123 PM 3 Installation Instructions By law at least one smoke alarm must be installed on each level of your home Figure 1B Recommended Locations In every room where someone sleeps with the door closed The closed door may prevent an alarm located outside from waking the Sleeper In the immediate area of bedrooms and the exit path from all sleep ing areas Figure 1A In stairways as stairways act like chimneys for smoke and heat In any room where large electrical appliances are operated e g portable heaters or humidifiers If a hallway or room is more than 9 1m long put alarms at both ends For maximum household protection see Figure 1C Things to Consider For Ceiling Mounting Smoke from a fire will rise to the ceiling and spread horizontally Mounting the smoke alarm in the centre of the ceiling places it closest to all points in the room When mounting an alarm on the c
22. uell com au Operational Model Visual Audible Mode Indications Indications Note Normal All Blink once every 60 sec LED will flash every 60 seconds for Operation onds 10 minutes following power on or reset After initial 10 minutes LED will flash once every 10 minutes Test Hush All Blink with each alarm Two sets of 3 long Test Hush button press will ini Button Press pattern beeps tiate test sequence P3010B Voice Fire Fire Bedroom smoke alarm with 135987 announced voice Model P3010B Part No 135987 Smoke Alarm Blink once every 10 None smoke alarm Alarm hush feature silences Hush seconds silenced smoke alarm for approx 10 minutes See page 13 for addi tional instructions Low Battery All Blink once every 30 Chirp every 60 se Chirp every 60 seconds seconds onds P3010B Voice Low Battery Bedroom smoke alarm with voice 135987 announced Model P3010B Part No 135987 Fault Mode All Fault code 2 12 Chirp every 30 Remove turn off and replace flashes every 30 seconds seconds alarm All 2 blinks every 30 sec 2 chirps every 30 Remove turn off and replace onds seconds alarm End of life hush feature Silences end of life indication 3 days at a time for a maximum of 30 days End of Life Hush This alarm has End of Life Hush which allows you to silence the trouble chirp for three days giving you extra time to replace the unit at a more convenient time To activate press the Test Hush button Whil
23. you have included an explanation of the problem If Chubb elects to repair the product please note that goods presented for repair may be replaced by refurbished goods of the same type rather than being repaired Refurbished parts may be used to repair the goods This warranty is provided by Chubb Fire amp Security Pty Ltd ABN 47 000 067 541 149 155 Milton Street Ashfield NSW 2131 Australia Telephone 1800 654 435 Website www quell com au Chubb New Zealand Limited 3 Fisher Crescent Mt Wellington Auckland New Zealand Telephone 09 270 7288 Website www quell co nz 47 000 067 541 AVE AQ OA Chubb lt 5 United Technologies Australian Standard AS 3786 Lic 1377 SAI Global

Download Pdf Manuals

image

Related Search

0312 7201 00(135986_135987_135988)_V5.qxd:_

Related Contents

Samsung 20" LED Монитор серии Q 2053BW Инструкция по использованию  Smart Card Writer_Reader Application, Ver. 4.1  USER`S MANUAL - inverter & Plc  Manuale di Installazione  GUIDE D`UTILISATION GZ-HD40 GZ-HD30  SECTION PAGE  Bedienungsanleitung  MANUAL DO UTILIZADOR/INSTALADOR  M. O. SGB2 FR  I-Sheet Piranha  