Home

Operation Manual

image

Contents

1. sssuuussse 39 Appendix Emissivity of Raw Material 40 1 Product Summary This new generation Infrared Camera equipped with Uncooled Focal Plan Array Micro bolometer produces crisp thermal image and accurate temperature reading to help increase system maintenance quality and efficiency in many industries This Infrared Camera is packed with advanced features such as colored thermal image voice annotation sound and color alarm FLASH memory storage USB connection to PC and analysis software Crisp thermal image accurate temperature reading clear user interface reliable product quality and affordable cost makes this Series Infrared Camera the new standard in Infrared imaging industry Typical Application e Power Plant Monitor and diagnose the condition of electrical wire and equipment detect power leak and prevent system malfunction Petrochemical Industry oil pipeline check material interface detect heat leakage insulation structure and power equipment detect Fire Protection forest fire protection and latent fire source search self ignition prevention and detection of special material electric fire precaution detect e Medical Application Accurately measure human body temperature in a distance critical under a contaminated condition e Building Industry humidity air leakage and insulation defects detect Other Applications Civil engineering university research and railwa
2. Software does not guarantee the quality performance or applicability of any hidden special purpose The contents of this manual will be updated because of device upgrade or other various reasons Our company reserves the right to edit this manual without further notice 2 Quality Assurance The quality administration system of this product during the process of R amp D and production has been approved in accordance with I809001 standard 3 Compatibility with Previous Versions This IRSee Software version supports all file and data created by any IRSee Software version 4 Compatibility with Infrared Camera This Software supports all JPEG format image recorded by TI Series Infrared Camera I Software Installation Welcome to Use IRSee software 1 Introduction The IRSee Report version has a friendly user interface 4 methods for measure analysis and the function to save analysis report in Word PDF Excel and other formats 2 System Requirements The files of the IRSee software consist of IR image visual image and graphic file all of which are far bigger than normal text files thus the following standards of the computer hardware configuration should be met 2 1 Hardware Requirements CPU PENTIUM Dual Core 2 0GHz processor or faster 1Gbytes or more system memory e 20G or bigger hard disk 1440x900 or higher resolution screen 2 2 Operating System IRSee Software is compatible with Microsoft Wi
3. Water 8 21 090 gt 096 ma Fine 21 090 40 Uncooled Focal Plane Infrared Cameras IRSee Report Software User Manual Table of Content Software Installation esses 1 1 Introduction 1 2 System RequirementsS rrrrnnrrrvrrnnnnrvvrrrnnnrrvrvnnnnrvennrnnsnnennnnnn 1 2 1 Hardware Configuration eeue esse ee ee ee ee ee ee ee Ee ee ee 1 2 2 Operating System iese ees ee Ee ee EE ee ee ee ee Ee ee ee 1 3 Software Installation ee ee EE ee ee RE Ee ee ee 1 4 Uninstall SOLOW ANE ausu os etse ESE ee ee ee ee sei ee ee 3 5 Start Software ee Ee ee EE ee ee ee RE ee ee ee ee ee ee ee 3 II Function Description ees ee Ee ee ee ee Ee ee ee Ee 4 1 Image Import and Export eeeeeseeeeeeeeeeee 4 1 1 Image Import rrnrnnnnnnnnnnrnvnnnnvnnnnnnvnnnnnrnnnnnnrnnnnnnrnnnnnnen 4 1 2 Image EX DOM AE N ED N 5 2 MOT NE EE EN DO EE RE EE NN 5 2 6 2 2 Measuring Temperature Zone 13 2 3 Histogram Area sees ee ee se ee ee ee ee ee ee ee ee ee EE ee ee EE ee 20 2 4 Line Profile Measurement Area 22 2 5 Color Code Area ee ee EE Ee ee ee ee EE ee ee 23 2 6 Label AEA Leien ER bies ds Res tein eo dos RE RE Se ee es ie 25 2 1 visible LOPIE sessies es EE DE Ee ge ER se isi 26 1 Limited Liability
4. There are 3 options for this infrared camera 11mm standard lens 6 3mm wide angle lens and 54mm telelens he camera may need 20 seconds to readjust a new lens before it can work properly Temp Unit Press Or to select Temperature Unit from c and K 9 5 32 K 273 15 Ambient Temp For more accurate measure result set Ambient Temp to correct environmental temperature Press 4 or once to change Ambient Temp 0 1 C Long press Or will change Ambient Temp in 19C interval Reference Set reference spot or area to display measure results as relative value Ref Temp Press Or once to change Ref Temp 0 19C Long press 4 or Will change Ref Temp in 19C interval This option is only active when set Ref Temp as reference Image Reverse Press OK button to reverse palette for thermal image display Press OK again to switch back Clear Screen Press OK button to clear all screen items except Logo mark L amp S Auto Manual Mode 30 Press OK button to switch between auto and manual rectifying In manual rectifying mode upper left corner of LCD display shows L amp S 5 2 4 Setup There are 4 items in Setup menu System Setup Time amp Date Factory Default and Information amp 2 34 5 EA System Setup CY Time amp Date P F actory Def ault n ormatioii La Setup Sub menu System Setup System Setup includes Language Auto Rectify Auto Save Video Tra
5. 2 Save Method 1 e Click the Save current image button to pop up a file selection dialog box Set select the file path name where the file is saved e Save the image in the current active window Method 2 e Click the File and select the M Save all images button to save all the modified images 2 1 2 Set 2 1 2 1 Emissivity adjustment Method 1 Please input a required emissivity value 1 100 in the Emissivity edit box Press the Enter key to confirm it Method 2 Click the Up and Down keys in the edit box to adjust and set an emissivity value 2 1 2 2 Humidity Adjustment ePlease input a required humidity value 1 100 in the humidity edit box ePress the Enter key to confirm 2 1 2 3 Distance Adjustment ePlease input a required distance value 1 1000 unit meter in the distance edit box ePress the Enter key to confirm 2 1 2 4 Ambient Temperature Select the option to show the actual ambient temperature while the thermal image is being shot 2 1 2 5 Dew Point Temperature Select the option to show the dew point temperature 2 1 2 6 Cancel Changes Click the Return to default settings button to recover the emissivity humidity ambient temperature or distance to its original state 2 1 3 Audio When analyzing thermal images with voice information buttons in audio section would be effective and show in green you can replay the voice saved with the image by clicking correspo
6. 76 C P2 0 96 31 65 C 31 65 C 31 65 C e Ill Emissivity 0 lt t F3 P 4 Note vw Detailed information 2 7 Visible Light Visible image 2 7 1 Open an Image e Click the Open button to pop up the file selection dialog box e Select a file to be added from the dialog box 2 7 2 Save an image e Click the ER button to pop up the file selection dialog box e Select an image format e Check set the path where the image is saved e Save the visible light image 26 2 7 3 Delete an image Click the delete button to delete the currently added visible image 2 7 4 Flip an image Ak di f Click the Or button to flip an image clockwise or counterclockwise Visible image mx 2 7 5 PIP This feature is available for any image that with visible light p Click the button to set an image 21 N e Setthe transparency Drag the lower left progress bar to adjust the PIP values between infrared image and visible image e Set infrared display range Drag the right two progress bars to adjust the infrared display range of interval or above upper or below lower limit iran Aergebereih enseber x matechern mark i gt Lu xd zu Click the OK button to save the file the updated image is displayed on the measurement area 28
7. 8 Technical Support For common mistakes and issues during operation please refer the following form If issue cannot be resolved please contact our technical support department For simple problems arising during operation please refer to the following table If the problem cannot be settled please cut off the power and contact our technical department No battery or batteries are not installed correctly Install battery correctly Camera cannot be Battery power is used up powered on Change battery or recharge e Save power mode power on after 5 seconds Device power off Battery power is used up automatically Change battery X Ambient temperature is too high or low Battery is not fully charged Battery power is soon recharge battery fully used up e Battery may already reach end of life 300 usage cycles use new battery to charge Nee imads Lens lid is closed g Remove lens lid Thermal image is black Black amp white palette may be selected and white restore factory default 39 9 Appendix Emissivity of Raw Material For reference purpose only Material Surface Temp CO Emissivity Aluminum Brass Unpolished Oxidized badly lron Cast Iron Wrought Iron Polished Cu om mm oe LE Jf 2 os Gomes 2 og Whi Carbon Candle smoke Blacilead rough 16 Color average Sol 0 20 1 1090 J Polished
8. K 6 Battery condition indicates current battery power condition 7 Point measure EF T 1 2 1 3 and 1 4 indicates temperature value of point 1 2 3 and 4 respectively 8 Line measure the temperature value in the crossing of measure line and cursor line 9 Area measure measure points within the area maximum minimum or average temperature is optional 10 Temperature distribution curve sample temperature distribution curve of the measure line 11 Point measure cursor 4 measure points can be selected 12 Cursor line it appears in line measure mode 13 15 Lower limit temperature upper limit temperature the lower and upper limit temperature of the color code at the same time 14 Color code color palette Any kind of color code is available in the palette 12 5 2 Main Menu Menu and sub menu items Press OK button when not in Hotkey mode to enter main menu Note if press OK button too long instead of enter main menu triggers manual rectify s l Measure amp iage N Setup Main Menu Using A and V button to select menu item and selected item is highlighted with white background Press OK or button to enter sub menu Press 4 button to return to previous menu or exit 13 5 2 1 File Using File menu to save playback delete thermal image and voice annotation File Sub menu 14 Manage Select Manage to preview thermal image add or edit voice annotation or delete
9. Report If a report is to be closed the system will prompt whether to save the report or not Click the OK button Save ir d Derktop My Cempulei Far My Documents Ig My Computer My Fed waak Plae me 9913 Goieki IR Ainahan God aner eee Report sire MILDE LOMyCrivers jekta Cue Input and select the saving path and file name and then click the Save button Click the report in Ribbon gt gt Edit Report Save ir fat Dezkiop rakte My Documents Mj My Computer Eg 335 19 oes or Poison Sef ears OMe Rept Cera Milos LMyrisers ohita mil MN LOUERE Rennet Fils name Save at ype Hx 11 Select a saved report to reopen and edit it 2 1 6 USB Direct Transmission only for device with Direct Transmission function 2 1 6 1 Connection Click the Ribbon Settings gt gt USB Direct Trans Ili USBPlayer EIER Device disenabled or play error Connect a device set to USB Direct Trans mode for the device Click the device iron on PC software interface gt gt Open the device gt gt Play 2 1 6 2 Video Click the device gt gt Record Savein 2 Desktop my Documents EG X My Computer My Recent my Network Places Documents 39 19 Disk1 OIR Analysis Software ODIRSee Report 100727 111009 O MyDrivers photo 3160 IUVSee Report My Documents ga My Computer ID My Network Save as type avi v Select a video path gt gt Input
10. reading range select the y bigger value Measure Auto Manual rectification 4 spots 3 areas available under real time mode max min and average temp line Measure Mode measure isothermal display temp difference measure and temp alarm sound color 12 Colors selectable including iron red Color Palette rainbow black white and white black etc Image Setup Auto Manual adjust contrast brightness Date Time Temperature Unit C F K 10 Measure Languages available namely Chinese System Setup simplified amp traditional English Italian Japanese Russian French German Korean Spanish and Portuguese Emissivity Adjustable from 0 01 to 1 0 Hectification Rectification temperature Input Atmospheric Trans Auto according to distance relative Correction humidity ambient temperature input Continued table Technical Specification Storage Media Built in Up to over 1500 images Memory Storage Storage Mode Auto Manual single frame image storage File Type JPEG with 14 bits measure data Voice 40 Seconds voice recording Annotation oer image built in microphone Battery Type Rechargeable Li lon Battery PORE 3 Hours Under normal temperature Power Supply Charging type Intelligent charger External Power 12V 5 DC Operation Temperature 20 04300 Temperature Operating Humidity lt 90 non condensing Grade Weight lt 780g Include battery and lens Physical Size LxWxH 330mmx95mmx86mm 38
11. state of mouse becomes click to select it Move the mouse to change the position of the vertex thus to modify the polygon Delete a Polygon eSelect the polygon to be deleted e Click the x button to delete selected Measured Objects 18 Add an ellipse e Click the S Add Area button to pop up a menu e Click the Ellipse ES e Select the starting point of the ellipse in the thermal image to be analyzed e Drag the mouse to create an elliptical analysis area Move and Drag an Ellipse Move Move the mouse into the ellipse to be moved When the state of mouse becomes click to select it e Move the mouse Zoomin out e Move the mouse into the ellipse to be modified e When the state of mouse VEE click to select it Move the mouse to the eight vertexes ze e When the state of mouse becomes T click to select it e Move the mouse to change the size of the ellipse Delete an ellipse Select the ellipse to be deleted Click the x button to delete selected Measured Objects 2 2 5 Save Images MI Click the Elsave Images button to pop up the file selection dialog box 19 Select image formats e Select set the file path Click the Save button to save the image 2 2 6 Clear measured objects Click the 8 Clear Measured Objects button to clear all point line area analysis of measured targets 2 2 7 PIP Infrared only for visible image Click the j button to switch between the PIP and i
12. thermal image File Manage Folder is automatically created if not exist when saving thermal image Folder name is MYYMMDD and YYMMDD is year month and date For example Jan 2 2009 folder is M090102 All thermal images taken in this day is saved in this folder Thermal image file name is Phhmmss and hhmmss is hour minute second according to system time For example P080502 in folder M090102 means the thermal image taken at 08 05 02 time in Jan 2 2009 In File Manage window press A and V button to select items Selected item is highlighted with red background Press 4and button to switch folder or file when highlighted After select thermal image press Open to view thermal image or Delete to delete Press Exit to exit File Manage window P1 2434 6 9 Thermal Image preview Press 40r button to switch saved thermal image in the same folder The J icon indicates voice annotation data with current thermal image Long press A button to enter Voice Annotation menu If voice annotation already exists press Record will record new voice annotation and erase previously saved one Press Cancel first to stop recording then press Save to save P1 2434 6 9 Info 575 Record Play Save Cancel Voice Annotation 16 Long press VY button to delete thermal image Delete Saved Thermal Image To exit thermal image playback long press OK button Save Save current thermal image Freeze image first bef
13. to change Alarm Temp 0 1 AE Long press 40r will change Alarm Temp in 19C interval Default setting is 37 0 C Alarm Color Alarm Color can select from Auto Black White Red Orange Yellow Green Blue Gray and Purple Default setting is Auto which is no color alarm Isotherm Color When this option is Auto there is no Isothermal display Otherwise target subject Infrared image will change to selected color when temperature is within the range of Isothermal Temp Isothermal Width 2 Default setting is Auto Isotherm Temp Press 4 or once to change Isothermal Temp 0490 Long press 4 or will change Isothermal Temp in 1 C interval Default setting is 37 0 C Isotherm Width Adjust Isothermal Width to change the range of Isothermal Color display Press 4 or once to change Isothermal Width 04 C 28 Long press 40r will change Isothermal Width in 19C interval Default setting is 1 09 C Screen Display When this option is Off screen display will clear battery condition temperature unit temperature limit and color palette Press 4 or to turn on off this option Analysis Setup Analysis Setup i 20 120 TEE Analysis Setup Sub menu Temp Range Select Temperature range base on measure target temperature from 3 options standard grade 20 120 C and medium grade 0 350 C and extra grade 350 1200 C which is customized IR Lens 29 Select correct IR Lens for best measurement result
14. will be unified 2 5 1 Default maximum or minimum temperature and upper and lower limits of isothermal color Click the button to reload default settings 2 5 2 Adjust upper and lower temperature Method 1 e Move the mouse tor L the upper and lower temperature on left side of the color bar e Whenthe mouse s status turns 4 please left click to select 23 Drag the mouse to the required temperature value position Method 2 Click the scroll bar on the arrow button to adjust upper and lower temperature each step is 0 1 2 5 3 Adjust upper and lower limits of isothermal color If the isothermal color is enabled a user can adjust the isothermal scope Method 1 e Move the mouse to he upper and lower temperature on right side of the color bar epus e When the mouse s status turns please left click to select Drag the mouse to the required temperature value position Method 2 Click the scroll bar on the arrow button to adjust upper and lower limits each step is 0 1 2 5 4 Select a dew point When a dew point is selected all points which temperature is below the dew point will be colored in uniform 2 5 5 Set isothermal color and dew point color The default isothermal color is fluorescent green the default dew point color is blue and the dew point is prior selected e Click the L Set Color button to pop up the color selection dialog box eSelect customize the backgrou
15. Laboratory Equipment Manufacturer le N TAB f www mrclab com CE NE Operation Manual Infrared Camera IR CAM 160 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 06 14 To Our Customer Dear Customer Thank you for choosing this Infrared Camera Please read this user manual carefully before first use Also please keep in a safe place for reference in the future Please operate with the recommended instructions in user manual We reserve the right to change this user manual without further notice NWARNING DO NOT USE WHEN RAININC DO NOT OPEN OR EXCHANGE PARTS REPAIR ONLY CAN BE CONDUCTED BY STUFF NOTICE In order not to cause malfunction or even damage the device please do not direct the lens towards strong high temperature radiation source such as the sun whether the power is on or off Avoid violent shock and impact during operation or transport e Storage temperature is between 40 C and 70 C The device must be kept in original packing case during transport Typical storage place is cool dry ventilated and without strong electromagnetic field Keep the lens surface off grease or any chemical substance which would damage the lens Close the lid after operation Please regularly backup data on PC to prevent potential data loss and format the internal FLASH memory duly to make i
16. Playback 1 Press OK button to open main menu 2 Select File gt Manage and select folder to view stored thermal image 3 When viewing thermal image press 4 button or button to switch image in the same folder 4 The J icon indicates voice annotation attached to current thermal image Press A button to playback 5 Long press OK button to exit 4 5 Replace Lens 1 Screw off the lens on device replace it with another lens and screw on tightly nad Screwing off CELL Screwing on 2 Press Or to adjust IR Lens in Analysis Setup menu 3 Operate Image Save and Image Playback according to the steps mentioned in 4 3 and 4 4 hereinabove 10 4 6 Connect to PC Connect device to PC using included USB cable Refer IR Analysis software manual for additional PC operation instruction It is recommended to format device periodically 5 Operation Menu 5 1 Display Summary All items can be selected by short pressing the Hotkey button Note Long press Hotkey button will turn on off laser sight The selected item is flashing in yellow color If no operation in 2 seconds after selection Hotkey mode will exit automatically 1 Symbol for 2X zoom symbol 2X denotes enlarge twice in size press A V button to realize the function 2 4 Area measure box 3 areas can be selected in area measure mode 3 Horizontal measure line Horizontal sampling line 5 Temperature unit there are three options
17. a Rect Measure 22 Parameters sesse es RE ee Ee ee Ee ee ee ee 24 zu a 25 Blige 25 aleae AE 25 AA USE RAD AE noari 26 DY AR Pdjust Teltip AED 26 Save o OUNO iiie er 26 O29 MAO EEE ics fuma 26 Image Selup io po e eoe ER EG 27 Alarm SWICM uie tdeo ettet 28 Aam TEMP surre 28 Alam COO uic ss ee EG 6s 28 Isotherm Color sssssse 28 Isotherm Temp 28 Isotherm Width 28 Screen Display esses 29 Analysis Setup certet eost e ee Se ennt 29 Temp Range eeeeeeeeee 29 EGAS MR MN Ee Re 29 Temp UM vane 30 Ambient TetTipzunsoii ie iei 30 Reference esses 30 Ref TED se 30 Image Reverse esse ee ee EE ee ee ee 30 Clear SCree N ese eek EE ee RR EE ee ee Ee 30 L amp S Auto Manual Mode 30 5 2 0 CUD ne 31 System SelUD tede elt Be ee 31 Languages veia ees Dad A oda 32 AUO REGI ME 32 MUSE 32 VIE 32 Transparente Luse 32 Display Device sss 33 Screen SAVE ee ee EE ee RE 33 POWEI SAVE Kara 33 Time amp Date ve 33 Factory Delta dl tem 33 Orma d ERN NT MCCC 33 Building Thermal Imaging Summary 34 Technical Specification 37 Technical Support
18. ed Completing the ffdshow Setup Wizard selg his hrsibend milling hers ori ou compuler he ape anon m r be launched by celezhra the rute icons Dik Finish In pad Setups O Fun sudo decoder configuration I Run videa decoder configuration LI Run 00004 wdeo decoder configuracion LI Fun VPw conguraton 4 Uninstall Software Please select the Delete button if want to reinstall the software 5 Starting up Software The following icon appears on Windows desktop after installing IRSee software Double click the icon and startup IRSee interface Open an image by menu open or icon B in the ribbon met P nr Aveoe omme we onsa te tratr Ar ep MA org PEN mpm we Note IRSee software has 10 different working languages namely Chinese simplified amp traditional English Italian Japanese Russian French German Korean Spanish and Portuguese IRSee software has auto recognition language function with the operating system in PC the IRSee will be in English version if the operating system is beyond mentioned languages in PC II Function Description 1 Image Import and Export 1 1 Image Import Method 1 Click the software icon on upper left corner to pop up the menu Click the Open button also available to select a recently opened image path in the image bar to pop up the file selection dialog box Select a file in the file selection dialog box single or multiple selecti
19. elect a background color Click the OK button to confirm the background color 21 2 3 6 Show Hide the Out of Range Column Click the button to show or hide any column out of temperature range of color code bar composed of points 2 3 7 Reset Click the had Reset button to reload the default state to the histogram 2 4 Line Profile Measurement Area Temperature line Ee temperature 2100 00 C MIH temperature 37 61 C Average temperature 69 94 me 2 4 1 Show hide grid lines Click the ES Grid button to switch the grid display and hide mode 2 4 2 Set the background color e Click the ce background color button to pop up color selection dialog box Select a background color Click the OK button to confirm the background color 22 2 4 3 Save the line profile measurement image Click the button to pop up the file selection dialog box Select an image format Check set the path to save the image Click the Save button to save the line profile measurement image 2 5 Color Code Area Pallete peut to o s OP EN xj 09 S 32 30 1632 M 28 It is available to adjust the type of color code 12 kinds of color bars are available A User can also adjust the maximum or minimum temperature and isothermal upper and lower limits any out of range temperature can not be supported If the dew point is selected the corresponding color code of below the dew point temperature
20. hich four parameters can be adjusted namely emissivity set reference measure type move size Attrib ute Area Rect Measure Attribute Emissivity Refer to Appendix Emissivity of raw materials Set Reference Set current area as reference If selected all measure result will be relative value to this temperature Measure Type Select from max min and average Adjust Adjust rectangle position and size Parameters Change different settings to adjust temperature measurement accuracy Press A and V button to select different parameters and press 4and button to change value 24 Parameters Parameter Sub menu Emissivity Emissivity varies based on target subject material surface temperature surface roughness measurement angle and etc Press 40r once to change Emissivity by 0 01 Long press 4 or Will change Emissivity in 0 1 intervals Distance This value can be omitted if target subject is close to device less than 10m Otherwise set Distance value accordingly to get more accurate temperature reading Press 4 or once to change Distance 0 1m Long press 4 or will change Distance in 1m interval Humidity This value can be omitted if target is close to device less than 10m Otherwise set Humidity value according to environmental condition Press 40r once to change Humidity 196 Long press 40r will change Humidity in 10 interval 25 Adjust Ratio Due to long ti
21. jects The prior sequence of object selection is point line and area 14 When two or more objects are simultaneously selected the system can operate in accordance with the above prioritization e g if both a point object and a line object are simultaneously selected the point is more prior than line the point object will be prior selected If both an area object and a line object are simultaneously selected the line is more prior than the area the line object will be prior selected If two or more areas are simultaneously selected the smaller area will prevail e g If Rectangle 1 and Rectangle 2 are simultaneously selected Rectangle 1 is smaller than Rectangle 2 Rectangle 1 will prevail 2 2 2 Point Analysis Create a point e Click the button e Move the mouse to a point to be analyzed and click it Move a point eMove the mouse to a point to be moved e When the mouse status changes to left click to select the point e Move the mouse Delete a point e Select a measurement point to be deleted e Click the X button to delete selected Measured Objects 2 2 3 Line Analysis Create a line Arbitrary line Click the al Create button to pop up a menu Click the Arbitrary Line button Set a starting point of the line in the thermal image to be analyzed Lleft hold and drag the mouse to the terminal point of the line 15 Vertical Line Click the Ed Create button to pop up a men
22. me usage of device the sensitivity of IR detector may decrease In such case it is necessary to adjust ratio value to get more accurate temperature reading During calibration if temperature reading is higher than actual target temperature change ratio value lower and vise versa Press 40r once to change ratio value 0 01 Long press 4 or will change ratio value in 0 1 intervals Adjust Temp Under certain condition it is necessary to adjust temperature reading by a pre define value Normally this option should be left unchanged Press 40r once to change 0 1 C Long press or will change this value in 1 C interval Save Setting All parameter changes must be saved before power off device Otherwise changes will not be saved for next power on 5 2 3 Image There are 5 items Image Setup Analysis Setup Image Reverse Clear Screen and Auto Manual L amp S in Image menu 26 Image Setup Image Sub menu Image Setup Image Setup Image Setup Sub menu 27 Alarm Switch Press 4 or turns on or off the alarm function If the Alarm owitch is on when target subject within area box has surface temperature exceeding Alarm Temp device will alarm with buzzer sound and mark the high temperature location as Alarm Color if Alarm Color is set Alarm Temp When Alarm Switch is off this option is disabled When Alarm Switch is on Alarm Temp is the desired alarm temperature Press 4 0r once
23. nd color eClick the OK button to confirm the selected color 24 2 6 Label Area The Label Area indicates detailed information of measured objects when the measured object changes the object s label will change accordingly the structure of label area is as below Markers Mame Emissivity Avgtemp Max temp Min temp Note P1 0 96 31 76 C 31 76 C 31 76 C P2 0 96 31 65 C 31 65 C 31 65 C lt gt Emissivity 0 lt A x Note Detaled information 2 6 1 Set the color of measured object Select a measured object in the label list e Click the ey button to set a color for currently selected object Select customize a color Click the OK button to conform the color of measured object 2 6 2 Add remarks for measured object Select a measured object in the label list e Add Remarks in the Remarks edit box 0 512 characters available e Click the Fi Upload Current Settings button to add remarks 2 6 3 Change emissivity of measured object e Select a measured object in the label list e Adjust the scroll bar of emissivity 2 6 4 Remove a measured object e Select a measured object in the label list e Click the N button to delete the currently selected object 23 2 6 5 Add detailed Information in Image remarks If any object in the label is not selected it is available to input information Markers Mame Emissivity Avgtemp Maxtemp Mintemp Note P1 0 96 31 76 C 31 76 31
24. nding buttons Otherwise the buttons would show in gray and cannot be operated 2 1 4 Set Temperature Type This option is used to set the temperature display unit click C F ork to set the temperature unit to Celsius Fahrenheit or Kelvin respectively 2 1 5 Report Wizard 2 1 5 1 Report Wizard Report Wizard is used for creating a report the Report Edit is mainly used for editing a report for further analysis Click the Report Wizard to select the type of exported report as needed Template Caere DEERE bihin adea Adrie Me Megat decrepit tapie tr Stand berei Bri Bede eien read Bride trek trial Replat yban Tr benir Byter Fill in related information in accordance with different types of report templates gt gt Preview 8 After necessary information completed you can click the save button to save the report as needed All reports have the same format of HX and repots can be edited again in IRSee software Inspection Report Company Customer name name Address Address Tel Fax Tel Fax E mail E mail Contact Contact Instrument name Instrument type Instrument serial Ha Lens Neasurement point Hame Address details Measurement description 10 NO File Date Measuring Time i P1 00503 JPG 2011 03 02 in 5 3 Emissivity 0 96 Remark i 0 98 sset c see sere mu gt ke ee Rei 096 4 410 793280 nwe Histogram Temperature line 2 1 5 2 Edit
25. ndows 2000 XP Vista Windows 7 lt provides a multi language version for users 3 Software Installation The instructions of IRSee software installation and necessary precautions before using this software will be given in detail hereinafter Please follow the instructions when installing IRSee software application Place software CD ROM into CD drive and run setup exe in the CD root directory The default route is C Program Files MRSee Report You can change directory when installing Note The software to operating and install in administrator on the Vista Win7 Step A Running the Setup exe the system indicates the installation path please adjust or change as needed IRSee Report InstallShield Wizard Welcome to the InstallShield Wizard for IRSee Report The InstallShield Wizard wil instal IRSee Report on your computer To continue click Next Step B Click the Next button to access the software installation IRSee Report InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation Ctck Install to begin the installaton If you want lo review ox Change any of your installation seltings click Back Dick Cancel to exit the wizard Step C Click the Next button continuously until the software installation is completed The system will enter the decoder installation automatically Step D Click and follow the default installation settings until the installation is complet
26. nfrared modes 2 2 8 Export Temperature Data Click the button to export all the points temperature in the whole thermal image to TXT file the temperature unit is Celsius 2 3 Histogram Area Hints mm omui x i 2 3 1 Relative absolute Scale If the relative scale is selected the vertical axis represents the percentage of the number of measured points if the absolute scale is 20 selected the vertical axis represents the actual number of corresponding measured points lt is available to click the H button to switch 2 3 2 Gradient Solid Color Display If the gradient histogram display mode is enabled the system can automatically select corresponding color to fill the histogram in accordance with the temperature If the solid color display mode is enabled the system will fill histogram with red it is available to click the i button to switch 2 3 3 Enable Disenable Grid If the grid is enabled it is available to draw grid dashed lines on the histogram background if disenabled it s unavailable to draw it is available to click the E button to switch 2 3 4 Save a Histogram Click the Save Images button to pop up the file selection dialog box Select the image format Check set the path to save the image Click the Save button to save the current histogram 2 3 5 Set the Background Color Click the e Set Background Color button to pop up color selection dialog box S
27. nsparence Display Device Screen Save and Power Save Press A and V button to switch selection and press 4 and button to adjust value Active item is highlighted with red background 31 System Setup English MM System Setup Sub menu Language There are 11 different language options Simplified Chinese Traditional Chinese English Korean Japanese German French Russian Italian Portuguese and Spanish Auto Rectify Set the number of seconds to perform next auto rectify Set value between 1 and 3000 seconds Value 0 means disabling auto rectify feature Auto Save Set the number of seconds to perform next auto save Set value between 5 to 3600 seconds Value 0 means disabling auto save feature Press 4 or once to change the value by 1 second Long press 40r will change the value in 10 intervals Video Select between PAL and NTSC Transparence Set to enable or disable menu transparence feature 32 Display Device Select between LCD display and external monitor device Only one video output device can be selected at one time the other one will be disabled El If accidentally selected external monitor device and LCD display is disabled power off and power on device to get LCD display back Screen Save Set the number of minutes without operation to trigger disabling LCD display to save power Select between 5min 10min 30min and None Power Save oet the number of minutes without opera
28. ons available Method 2 Click the Open button in the ribbon 1 2 Image Export It is available to export in accordance with the following methods after importing images Method 1 e Clickthe button Save Picture As button on the software icon on the upper left corner to pop up a file selection dialog box Select a file path and save the image in the current active window Method 2 Click the property analysis in toolbar Click the button Save picture As button to pop up a file selection dialog box Select a file path and save the image in the current active window Method 3 Click the software icon on the top left corner Click the button Save current picture to save the modified image on the current active window Method 4 Click the property analysis in Ribbon Click the button Save current picture to save the modified image on the current active window 2 Modules As displayed on the software interface the software has the follows the Quick Access Toolbar Hibbon Measuring Temperature Zone Histogram Area Line Profile Measurement Area Color Code Area Label Area and Visible Area 2 1 Ribbon The Ribbon is composed of File Parameters Audio Temperature Type Settings Report Wizard USB Panel and Language 2 1 1 File 2 1 1 1 Open e Click the File button to pop up a file selection dialog box Select and open a file to be analyzed in the dialog box 2 1 1
29. ore saving Format Format the internal FLASH memory Press OK to confirm or cancel to exit Format will erase all saved thermal images It is recommended to transfer data to PC before format 5 2 2 Measure There are 5 items Spot Line Area Rect Parameters and Save Setting in Measure menu 17 Pr Line ro EE Rect y AT Parameters OK Save Setting Measure Sub menu Spot Measure Press 40r button to select or deselect Selected spot is check marked Up to 4 spots can be selected at the same time Spot Target Selection 18 Spot Measure Measure result on upper right LCD corner is temperature reading at location marked with i Up to 4 spots can be selected Spot Measure Attribute Press Hotkey button until spot marker is flashing in yellow and then use A V 4 buttons to move spot location to different directions Press OK button to enter Attribute Menu After 2 seconds with no operation system will exit to real time Infrared view screen Spot Measure Attribute 19 Emissivity Refer to Appendix Emissivity of raw materials Set Reference Set current spot as reference point If selected all measure result will be relative value to this spot temperature Line Measure There are 2 line measure options vertical and horizontal Horizontal Line Measure Horizontal Line Measure Horizontal line is temperature sampling line and upper right LCD corner displays temperature meas
30. ove IR Lens lid if closed point to target and adjust focus to get crisp thermal image Long press OK button to rectify thermal image 4 2 Measure Target Temperature 1 Point device to measurement target and adjust to correct focus On the upper right LCD corner xx displays the spot measurement result For better accuracy long press OK button to perform manual rectify 2 Select Area Rect Measurement to measure max min and average temperature within a rectangle box 3 Itis recommended to press 4 button to freeze thermal image first and then apply different and detailed analysis Press 4 button one more time to unfreeze 4 Press A button or V button to switch between normal and 2X zoom Upper left LCD corner displays x2 when in 2X zoom 5 When measure result is outside temperature range screen display changes to indicate either below or above temperature range 4 3 Infrared Image and Voice Annotation Each thermal image can save up to 40 seconds voice annotation data Image and voice annotation can later be reviewed on PC by bundled IR Analysis software To save Infrared image first press button to freeze image and then long press 4 button again to open the voice recording menu If only needs store Infrared image select Cancel otherwise select Record Press OK button to confirm In main menu File Save provides the same function LL Select Cancel during voice recording to exit 4 4 Infrared Image
31. t operate properly Table of Contents 1 Product Summary ese ees es ee ee EE ee ee 1 1 t Standard EN LISE vase EDE EE AE dave 2 1 2 Optional ltem List ee ee ee EE ee RE EE ee Re 2 Battery and Charger 3 2 1 Charging Battery eseeesssseeeesss 4 2 2 Direct Charging Lasses ean 4 2 3 Attention for Using Battery Charger 4 Panel Function Summary 5 3 1 Main Control Panel see ee se ee Ee ee ee ee 5 3 2 Rear Interface Panel iese ee RE ee ee 6 ee ole di AE E 8 Quick Start Reference 8 4 1 Infrared Image eese 8 4 2 Measure Target Temperature 9 4 3 Infrared Image and Voice Annotation 9 4 4 Infrared Image Playback 10 4 5 Replace Lens ccccseccceseeceseeceeeeseseeeeeeesneeeens 10 4 0 Connect IO P as ie apttd De onde 11 Operation Menu rrrrnrnnnnornrnnnnonrrnnnnnnnnnnnnnnnnnn 11 5 1 Display SUMMIERE EE ee SE Ex SEGUE oa suben esit 11 SAUCE HM 13 cu M c 14 Mire TN 15 ye EE 17 well ER OR OE EN 17 5 2 2 Measure ee ee ER ER RR EE nennen EE Ee ee 17 Spol Mea SUTE iss GE ro EE RE EE diet 18 Line Measure ees ee ee Ee ER ee Ee ee 20 Are
32. tarting point of the rectangle in the thermal image to be analyzed eDrag the mouse to create a rectangular analysis area Move and Drag a Rectangle Move e Move the mouse into the rectangle target area When the state of mouse becomes Click to select it e Move the mouse Zoom in out e Move the mouse into the rectangle to be modified e When the state of mouse becomes gt click to select it e Move the mouse to the eight vertexes of the rectangle JL When the state of mouse becomes T click to select it Move the mouse to change the size of the rectangle 17 Delete a rectangle eSelect the rectangle object to be deleted e eClick the x button to delete selected Measured Objects Create a polygon Click the Elcreate Polygon to pop up a menu eClick the Polygon ijj Select the starting point of the polygon in the thermal image to be analyzed eMove the mouse and left click to add other vertices of polygon Right click to stop adding the vertexes to create a polygon elt the number of vertexes is equal to or more than 50 the system can stop adding automatically Move and Drag a Polygon Move X Move the mouse into the polygon to be analyzed e When the state of mouse becomes Click to select it e Move the mouse Zoom in out e Move the mouse into the polygon to be modified When the state of mouse becomes click to select it Move the mouse to a vertex to be modified JL When the
33. the battery or put it into fire which may cause explosion Do not try to modify the battery or the charger 5 Please remove the charger from AD socket as soon as charging is completed 3 Panel Function Summary In this manual long press means Long press button down for about 2 seconds and press or short press means press and release 3 1 Main Control Panel 1 Power ON OFF Button Long press this button to turn on or off the device 2 Power LED Light When device is powered on the Power LED Light will be on 3 4 5 6 Direction Buttons Up A Down VY Left 4 and Right 4 direction buttons have different usage in different mode In main menu direction buttons are used for moving selected items or changing slide bar value In real time Infrared view mode directions buttons provide one click access Press 4to freeze Infrared image and press again to unfreeze Long press to save current Infrared image Press A or V to switch between normal view and 2X zoom After press Hotkey button refer page 8 3 3 and in area measure mode e Select the measure spot press A V 4 and to move the spot in the same direction e Select the measure line and sampling line press A V amp and to move the line in the same direction Select area box in move menu press A V 4 and gt moves area box and in size menu press A Y 4 gt resizes area box Select Color Palette or temperature meas
34. the name of the video file 2 1 6 3 Stop the video Click File gt gt Stop Recording 12 2 1 6 4 Pause Stop and Close Direct trans Click the Pause Stop and Close buttons under the File menu Oma xF _ 1 1 1 1 i i 1 lapa ss lih m E ram E z P Is iidem mies Lun Ja wm ju oes ques jam joe jee fim san SIT RR ME 2 1 6 5 Print Screen Click the Print Screen button and save the printed image into the Picture folder under the installation directory and name it by a time format 2 1 7 Panel It is mainly used for showing hiding each area a user can adjust the size and position of each display area as needed and then click the Save Settings to save the current settings and click the Return to defafult settings to recover 2 2 Measuring Temperature Zone The functional options in measuring area are shown below 13 Thermal image HassoxMN Tr The measurement objects can analyze the thermal images by the following three kinds of analysis methods point line and area Line measurement analysis has four types arbitrary line horizontal line vertical line and multiple line analysis Area measurement analysis has below rectangular elliptical and polygonal analysis The system can analyze up to 20 spots objects 10 lines analysis object 20 area analysis objects 10 polygonal objects and 10 elliptical objects simultaneously 2 2 1 Select Measured Ob
35. tion to trigger power off completely Select between 10min 20min 30min and None Time amp Date Set system date and time Press or V button to select an item press lt or button to change its value and press OK button to confirm If Li lon battery is removed for a long time it is necessary to reset system time and date Factory Default Restore factory default and rectify some improper settings Information Select to display system information such as serial number software version and production date etc 33 6 Building Thermal Imaging Summary As the quality of life improves and the low carbon life style becomes known higher demands are being set on buildings The features of our IR camera make it possible to detect slight temperature difference and to analyze indoor humidity and leakage Hereinafter are images in some cases The effect drawing of building detection The effect drawing of indoor humidity 34 The effect drawing of indoor water leakage The effect drawing of indoor corner air leakage 35 36 The effect drawing of outdoor corner air leakage 7 Technical Specification IR New UFPA micro bolometer Detector Pixel Spacing Standard Lens 21 x169 0 15m l Wide angle 35 x27 0 05m SES telelens 4 x397 0 8m Infrared Image Quality Spectral Range Display LCD 3 5 Color LCD Temperature 20 C 120 C 0 C 350 C Range Up to 1200 Coptional Renae 2 or 2
36. u Click the MB Vertical Line button Set the vertical coordinates of starting point of the line in the thermal image to be analyzed Left hold and drag the mouse to the vertical coordinates of terminal point of the line Horizontal Line Click the 3 Create button to pop up a menu Click the amp Horizontal Line button Set the horizontal coordinates of starting point of the line in the thermal image to be analyzed Left hold and drag the mouse to the horizontal coordinates of terminal point of the line Move and change a line 16 Move e Move the mouse to the position of a line to be moved When the state of mouse becomes d left click to select it Andthen move it Change the positions of starting point terminal point e X Move the mouse to the position of the line to be moved When the state of mouse becomes 7 left click to select the line e Move the mouse to the position of starting point terminal point to be moved When the state of mouse becomes d left click to select starting point terminal point Drag the mouse to the required position of starting point terminal point Delete a line eSelect the line measurement object to be deleted e Click the x button to delete selected Measured Objects 2 2 4 Area Analysis It has three areas rectangle polygon and ellipse Create a rectangle eClick the Elcreate Area button to pop up a menu eClick the Rectangle E eSelect the s
37. urement limit Press 4 to change and A V has no effects 7 OK Menu Confirm Button This button has different functions under different conditions In real time Infrared view mode press this button opens the main menu In main menu press this button to confirm operation In real time Infrared view mode long press this button to manually rectify measurement result In image viewing mode long press this button to exit I After auto rectifying if device has abnormal noise long press OK button to perform manual rectifying usually solves such Issues 8 MIC Internal MIC records audio annotation 9 Laser Sight Long press Hotkey button to turn on off laser sight 3 2 Hear Interface Panel 13 12 10 Video Output CVBS standard video output 11 Audio Output Audio output playbacks recorded voice annotation 12 USB 2 0 Interface USB2 0 interface transfers data between device and PC 13 External DC In External DC requirement is 12V 3 3 Side View 14 14 Hotkey Button Press Hotkey button to switch between Color Palette area measurement rectangle temperature limits and long press Hotkey button to turn on off laser sight 15 Sound Alarm Buzzer Signal sound alarm when reaches temperature limit 4 Quick Start Reference 4 1 Infrared Image 1 2 3 Insert Li lon battery correctly Long press Power button until LED light is on and wait until system finishes initialization Rem
38. urement reading on vertical cursor line intersection After using Hotkey button select line measure press A and V button to adjust sampling line position and press 4 and button to adjust cursor line position Press OK button to enter Attribute Menu After 2 seconds with no operation system will exit to real time Infrared view screen 20 Attribute Horizontal Line Measure Attribute Vertical Line Measure Vertical Line Measure 21 Vertical line is temperature sampling line and upper right LCD corner displays temperature measurement reading on horizontal cursor line intersection After using Hotkey button select line measure press and button to adjust sampling line position and press A and V button to adjust cursor line position Press OK button to enter Attribute Menu After 2 seconds with no operation system will exit to real time Infrared view screen Vertical Line Measure Attribute Area Rect Measure Press 40r button to select or deselect Selected Area is check marked Up to 3 areas can be selected 22 Area Rect Target Selection Rectifying Area Rect Measure Measure result on upper right LCD corner is the temperature measurement result within the corresponding rectangle There are 3 measure types max min and average temperature 25 Area Rect Measure Attribute Press Hotkey button until area rectangle is flashing in yellow Press OK button to enter Attribute Menu in w
39. y etc 1 1 Standard ltem List This Series Infrared Camera comes with the following standard items and accessories hem gt Infrared Camera Li lon Battery Battery Charger USBCabe USB Cable Suitcase 1 2 Optional Item List e Wide Angle Lens e Telephoto Lens 2 Battery and Charger It is recommended to charge battery immediately when device indicates low power By press and move in the indicated direction user can easily insert and remove battery A Battery Insertion Battery Removal Device comes with two sets of Li lon battery and one battery charger It is strongly recommended to operate only with the included battery and charger Use any other brand charger or Li lon battery may cause fire or critical damage 2 1 Charging Battery 1 Following the direction indicated on battery charger insert the Li lon battery press firmly and push all the way in 2 During charging the red LED will be on and when charging is completed the green LED will be on instead LJ Normally it takes 3 hours to completely charge one battery 2 2 Direct Charging 1 The battery can also be charged by using an adapter Normally it takes 5 hours to charge one battery in this mode 2 9 Attention for Using Battery Charger 1 Battery Charging can only be conducted inside of a house 2 Do not short circuit the battery 3 Do not put the battery in high temperature environment 260 C Never disassemble

Download Pdf Manuals

image

Related Search

Related Contents

Untitled  performance  Sony 331 Portable CD Player User Manual  Паровой утюг VT-1245 DB, P + Gift Steam iron  35FR PLUNGER PUMP SERVICE MANUAL - Three-Es  User Manual  Des brevets en instance pour Hepasil DTXMC, le supplément d  Benutzerhandbuch  Pure Digital EVOKE 1XT User's Manual  Manual de instruções - VEGABAR 81  