Home
JB0112-016 User Manual
Contents
1. Field and John Bunn are registered trademarks and Vacutec is a trademark of GF Health Products Inc Packaging warranties products and specifications are subject to change without notice GF Health Products Inc is not responsible for typographical errors GF Health Products Inc July 2009 All rights reserved 1 SAFETY INFORMATION When using electrical products especially when children are present basic safety precautions should always be followed Read all instructions before using Please note the following special statements used throughout this manual and their significance A DANGER Indicates an imminent hazard situation that if not avoided will result in death or serious personal injury A WARNING Indicates a potential hazard situation that if not avoided could result in death or serious personal injury A CAUTION Indicates a potential hazard or unsafe practice that if not avoided could result in product or property damage NOTE Provides application recommendations or other useful information to ensure that you get the most from your product READ THIS ENTIRE MANUAL BEFORE USING THE ASPIRATOR SAVE THIS MANUAL 2 JB0112 016 INS LAB RevA09 A DANGER To reduce the risk of electrocution 1 Do not use while bathing 2 Do not place or store product where it can fall or be pulled into a tub or sink 3 Do not place in or drop into water or other liquid 4 Do not reach for a product that has fallen into w
2. tubing kinks Ensure that float shut off is not activated Check for bottle leaks and cracks Low vacuum Use vacuum adjust knob to increase vacuum level Check system for leaks Adjust vacuum adjust knob and release Motor overheats and motor overload Turn ON OFF switch OFF allow motor to cool protector shuts off motor for approximately 5 minutes then restart aspirator Inspect fuse and replace if necessary Contact your GF authorized distributor if unit still does not start up Blown fuse Replace fuse with same size and type Miniature glass fuse 5 x 20 mm fast blow quick acting F2A 250 V lf you are unable to resolve the problem please contact your Graham Field authorized distributor 9 JBO112 016 INS LAB RevAO9 11 SPECIFICATIONS CLASSIFICATION Dimensions L x W x H 15 3 in x 4 9 in x 10 in 389 mm x 124 mm x 254 mm 11 6 Ib 5 3 kg 16b 6839 o 10 2 15 4 psi 70 106 kPa 7 3 15 4 psi 50 106 kPa ee Miniature glass fuse 5 x 20 mm fast blow quick acting Fuse Specification F2A 250 V Equipment Classification Class JBO112 016F Replacement bacteria HEPA filter JBO112 016B Collection bottle Replacement Parts JBO112 016S Suction tube Specifications are subject to change without notice 10 JBO112 016 INS LAB RevAO9 12 TWO YEAR LIMITED WARRANTY GF Health Products Inc warrants the John Bunn JB0112 016 Vacutec 800 EV2 Aspirator and its components to be free f
3. 016 INS LAB RevAO9 U S A Corporate Headquarters GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 GRAHAM FIELD www grahamfield com
4. ING Proper operation of this product is necessary to avoid physical harm Improper use Can Cause personal injury and or tissue damage This product should not be used unless the operator has been instructed by a physician or another qualified healthcare professional 1 Familiarize yourself with this unit 2 Place unit on table and push down hard so that suction feet hold unit firmly in place 3 Before plugging power cord into electrical outlet ensure the ON OFF switch is in the OFF position NOTE Before attempting to start a cold unit let the unit reach room temperature in a heated area 4 INTRODUCTION The John Bunn Vacutec 800 EV2 Aspirator is a professional medical suction device that produces a maximum vacuum of 560 mmHg The unit is equipped with an 800 cc collection bottle and has been designed for convenient and reliable use Features e HEPA filter design helps prevent contamination e Mid size aspirator for medium duty use e Quiet and compact quick recovery time e Automatic shut off e Designed for single patient use e Oil free permanent lubrication e High reliability and superior performance allow continuous operation Following the recommended operating and maintenance procedures outlined in this user manual will maximize the life of this product Refer to the diagrams on the following pages 4 JBO112 016 INS LAB RevA09 5 ILLUSTRATION OF IMPORTANT PARTS tubing a collection bottle to N bacteria HEPA filter
5. JOHN BUNN WACUTEC JBO112 016 Medical Equipment Complies with EN60601 1 standards User Manual A Federal law USA restricts this device to sale by or on the order of a physician This product should not be used unless the operator has been instructed by a qualified healthcare professional Q This device is for use by one person only in order to avoid infection do not share it NOTE Check ALL parts for shipping damage If shipping damage is noted DO NOT use Contact your Graham Field authorized distributor for further instruction NOTE Do not use the Aspirator without first reading and understanding this manual Save this manual for future use NOTE The most current version of this manual can be found online at www grahamfield com JB0112 016 INS LAB RevA09 Contents 1 Safety Information 0 0 0 cee eee 2 2 AC Power SOUICE 1 ee 3 So ElCCUIGAl ge2dancneud et cceue Geegus 48G04 bee ohne ee 4 A IPMPOGQUCHOM tus4 ueue estr erise py eh eee sens eaten ae ee 4 5 Illustration of Important Parts 0 0 000 cee 5 O SGUD wees Geese sededeeeeebastaeerenddeseuteesnenee as 5 7 How to Operate Your John Bunn Aspirator 6 8 Cleaning Instructions 0 0 cc eee ri 9 Maintenance 0 eee 8 10 Troubleshooting 0 eee 9 11 Specifications Classification 0 0 00 eee aes 10 12 Limited Warranty 0 0 00 ccc ees 11 Graham
6. ater Unplug immediately A WARNING To reduce the risk of burns electrocution fire or personal injury 1 Close supervision is necessary when this product is used by on or near children or those who need extra care 2 Use this product only for its intended use as described in this guide 3 Never operate this product if a It has a damaged power cord or plug b It is not working properly c It has been dropped or damaged d It has been dropped into water 4 Return the product to a Graham Field authorized distributor for examination and repair 5 Keep the power cord away from heated surfaces 6 Never use while drowsy or asleep 7 This device is for use by one person only in order to avoid infection do not share it A SPECIFIC WARNINGS TO REDUCE THE RISK OF ELECTRICAL SHOCK OR PERSONAL INJURY DO NOT DISASSEMBLE THIS UNIT Disassembly or attempted repairs if accomplished incorrectly can create electrical shock hazard Only qualified technicians should perform servicing of this aspirator Contact your Graham Field authorized distributor for service A DANGER The John Bunn Vacutec 800 EV2 Aspirator is a vacuum suction device intended for the collection of nonflammable fluid materials in medical applications only Improper use during medical applications can cause injury or death For all medical applications 1 All suctioning should be done in strict accordance with appropriate procedures that have been established by a
7. clean damp cloth A WARNING The waste in the collection bottle which could cause respiratory infection must be handled according to medical waste disposal regulations The operator must wear gloves and a medical class mask before cleaning the collection bottle and tubing or handling the waste unit and or accessories 9 MAINTENANCE Inspect suction tubing and collection bottle for leaks cracks etc before each use If found discontinue aspirator use immediately and contact your Graham Field authorized distributor A DANGER Electric shock hazard Do not attempt to open or remove the suction cabinet If service is required contact your Graham Field authorized distributor Opening or tampering with the unit will void the warranty Bacteria HEPA Filter Change 1 Replace the bacteria HEPA filter when either of the following two conditions occurs a the filter is dirty and the aspirator has lost suction or b there is liquid in the filter assembly as result of extended use or overflow If overflow occurs change the filter immediately 2 Remove the filter by disconnecting it from the tubing connected to the vacuum gauge and the tubing connected to the collection bottle lid assembly tubing a collection bottle to bacteria HEPA to Or collection B bottle ia g amp vacuum gauge z AN A tubing b bacteria HEPA filter to vacuum gauge bacteria HEPA filter Figure 8 3 Replace with a new J
8. d in the collection bottle reaches the safe full level 800 cc the float shut off will activate automatically and suctioning will stop Safe Full Level Figure 6 collection bottle 6 JBO112 016 INS LAB RevAO9 6 Switch the ON OFF switch to the OFF position to shut off the suction motor Unplug the aspirator when not in use 8 Remove the liquid from the collection bottle after the motor stops turning completely Please refer to the following CLEANING INSTRUCTIONS section for directions to clean the collection bottle 9 Switch the ON OFF switch to the ON position and start to run the aspirator again N NOTE 1 If the unit sustains a severe drop the validity of the gauge must be checked Inspect the float Shut off to ensure it still functions properly when the liquid in the collection bottle reaches the safe full level 2 Always transport unit with vacuum adjust knob rotated fully clockwise in case the unit is dropped A CAUTION 1 When automatic float shut off is activated empty the contents of the collection bottle immediately Further suction could cause damage to the vacuum pump 2 Should fluid be aspirated back into the unit contact your Graham Field authorized distributor for a detailed inspection as the vacuum pump may have been damaged 8 CLEANING INSTRUCTIONS iubing a collection bottle Clean Collection Bottle a ene wren 1 Turn off the aspirator allow vacuum to drop then disconnect AC power sourc
9. e 2 With the collection bottle still in the at holder remove the collection bottle lid holder a The bottle can now be taken out of the unre collection bottle lid holder to be emptied many NOTE Empty the collection bottle f immediately after each use collection bottle Figure 7 3 Clean the collection bottle after each use by using one of the following three methods a Wash in a hot water dishwashing detergent solution and rinse with clean hot tap water Then wash in one part vinegar to three parts hot water solution Rinse with hot tap water and air dry b Wash with rubbing alcohol and air dry c Wash with a commercial bacterial germicidal disinfectant follow disinfectant manufacturer s recommended instructions and dilution rates carefully Clean Aspirator and Collection Bottle Lid 1 Disconnect the aspirator from all external power sources 2 Wipe the aspirator housing and collection bottle lid with a clean cloth and any commercial bacterial germicidal disinfectant A CAUTION Do not submerge unit in water as this will result in severe damage to the vacuum pump T JB0112 016 INS LAB RevA09 Clean Tubing 1 Disconnect the tubing from the unit 2 Rinse the tubing thoroughly after every use by running hot tap water through it followed by a solution of one part vinegar to three parts hot water 3 Rinse with hot tap water and air dry 4 Keep the outer surface of the tubing clean by wiping with a
10. ing with original equipment specifications are added to GF Health Products Inc products or if the product or part is serviced by an entity not authorized by GF Health Products Inc THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED WARRANTY SHALL BE LIMITED TO THE REPAIR REPLACEMENT CREDIT AND OR REFUND OF THE DEFECTIVE PRODUCT OR PART PURSUANT TO THE TERMS CONTAINED HEREIN GF HEALTH PRODUCTS INC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state province to province Some states provinces do not allow the exclusion or limitation of incidental or consequential damage or limitation on how long an implied warranty lasts so the above exclusion and limitations may not apply to you This warranty contains the entire agreement between the parties and supersedes any prior contrary or additional representations or understandings whether oral or written concerning our warranty policy GF Health Products Inc Graham Field 2935 Northeast Parkway Atlanta GA 30360 Tel 800 347 5678 Fax 800 726 0601 11 JBO112
11. licensed medical authority 2 Some attachments or accessories may not fit the tubing supplied All attachments or accessories should be checked prior to use to assure proper fit 2 AC POWER SOURCE A CAUTION The Model JB0112 016 uses a power supply allowing operation on AC voltage 115 VAC 60 Hz However the correct power source must be used to connect to adaptable wall power Before use check the specification label on the side of the aspirator to ensure that the voltage and current indicated on the unit match the voltage and current available 3 JBO112 016 INS LAB RevAO9 3 ELECTRICAL Compressor If the overload protector shuts off the motor frequently you may have a low voltage situation Low voltage can also be suspected when 1 The motor does not get up to full power or speed 2 Other motor operated appliances fail to operate properly Too many motor operated appliances on same circuit NOTE The aspirator s compressor motor has a thermal overload protector If the motor overheats the overload protector will shut off the motor If this occurs turn the ON OFF switch to the OFF position and allow the motor to cool approximately 5 minutes Restart aspirator If the aspirator fails to start wait an additional 5 minutes before attempting to restart If this fails inspect your aspirator fuse and replace if necessary If the unit still does not restart contact your Graham Field authorized distributor immediately A WARN
12. lid bacteria gauge HEPA filter DH Gauge p lt vacuum adjustment knob bacteria D ji HEPA filter to vacuum gauge amp b ge tubing b suction tubing Wel 5 pa ON OFF holder w switch A power collection rubber foot bottle 4 total fuse Figure 1 Figure 2 6 SETUP 1 Connect both pieces of tubing a Connect one end of tubing a to the top of the collection bottle connector and the other end to the bacteria HEPA filter as shown in Figure 1 b Connect one end of tubing b to the open end of the bacteria HEPA filter and the other end to the vacuum gauge as shown in Figure 1 2 Connect the suction tubing to the top of the collection bottle at the outlet labeled patient as shown in Figure 2 Ensure that all connections are secure and without leaks before use 3 Before use check the specification label on the side of the aspirator to ensure that the voltage and current indicated on the unit match the voltage and current available Make sure the ON OFF switch shown in Figure 2 is in the OFF position before connecting the unit to a power source A Read SETUP WARNINGS before continuing A SETUP WARNINGS 1 This device is equipped with a three prong grounding plug for protection against possible shock hazard Plug only into a properly grounded three prong wall receptacle Where a two prong wall receptacle is encountered contact a licensed professional to have the two prong
13. lth Products Inc product Upon receiving notice of an alleged defect in a product GF Health Products Inc will issue a return authorization The defective product or part s must then be returned at the purchaser s cost for warranty inspection using the serial number as identification or if the product is not serialized lot number and date code within thirty 30 days of return authorization issue date In the event you do not receive satisfactory warranty service please contact GF Health Products Inc at the address below DO NOT return products to our factory without prior authorization LIMITATIONS AND EXCLUSIONS The foregoing warranty excludes consumables such as filters and tubing as these require routine maintenance The foregoing warranty shall not apply to serial numbered products if the serial number has been removed or defaced Products subjected to negligence abuse misuse improper operation improper maintenance improper cleaning improper storage or damages beyond GF Health Products Inc s control are not covered by this warranty and that evaluation shall be solely determined by GF Health Products Inc This warranty shall not apply to problems arising from normal wear and tear or failure to follow instructions The warranty shall also not apply to products modified without GF Health Products Inc s express written consent nor shall it apply if parts not manufactured by GF Health Products Inc or if parts not comply
14. ohn Bunn bacteria HEPA filter and connect it to the tubing connected to the vacuum gauge and the tubing connected to the collection bottle lid assembly as formerly positioned Additional filters can be purchased from your Graham Field authorized distributor NOTE Use only John Bunn filters Do not substitute any other material for this bacteria HEPA filter Improper substitution may lead to contamination or poor performance 8 JBO112 016 INS LAB RevAO9 Fuse Change 1 Use only the same type and size of fuse to replace the broken fuse 2 Fuse specification Miniature Glass Fuse 5x20mm Fast Blow Quick Acting F2A 250V A WARNING When this unit or its accessories reach the end of their useful lives dependent on conditions of use residue in the collection bottle tubing and filter could cause respiratory infection Dispose of the collection bottle tubing and filter appropriately according to medical waste disposal regulations Figure 9 10 TROUBLESHOOTING Your John Bunn aspirator contains no user serviceable parts If you believe your unit is not working properly before you contact your Graham Field authorized distributor for service please take a few moments to check for these possible causes PROBLEM ACTION Unit does not turn on Check power source and connection Ensure that the wall outlet is live Check power cord for damage Motor runs but no vacuum Verify tubing connection security Check for leaks or
15. receptacle replaced with a properly grounded three prong wall receptacle in accordance with the National Electrical Code DO NOT modify the plug in any way If an extension cord must be used use a three conductor cord with the same or higher electrical rating as the aspirator cord with ground properly wired in good electrical condition and keep it as short as possible Locate all cords so that they will not be stepped on tripped over or otherwise subjected to damage or stress 5 JBO112 016 INS LAB RevA09 Position the HOW TO OPERATE YOUR JOHN BUNN ASPIRATOR Make sure the ON OFF switch located on the side of the unit is in the OFF position Plug the aspirator into a properly grounded ON OFF power outlet FL e switch OFF ON position position Switch the ON OFF switch to I position Figure 3 ON the unit will start running ON OFF switch vacuum gauge Adjust the vacuum level from 0 to 560 mmHg by turning the vacuum adjust knob clockwise to increase vacuum and counter clockwise to decrease vacuum Refer to the vacuum gauge while setting the desired level of vacuum To accurately read the gauge block the patient end of the hose or cap off the collection bottle and allow the gauge to reach a stable vacuum reading an Figure 4 adjustment knob suction tubing appropriately for patient and begin suction Figu reo suction tubing collection bottle When the liqui
16. rom defects in workmanship and materials for a period of two years This warranty is extended only to the original purchaser consumer or distributor non consumer of this new product and to no other purchaser or transferee The Warranty period for the consumer commences on the first date a product is delivered to consumer by seller distributor If the product is rented or leased the warranty period commences on the invoice date from GF Health Products Inc A copy of the invoice showing date of purchase must be provided when submitting warranty claims When proof of purchase date is not provided warranty coverage shall commence upon GF Health Products Inc s invoice date to the distributor purchaser If within the warranty period the product or component part is proven to GF Health Products Inc s satisfaction to be defective GF Health Products Inc shall provide at its option one of the following 1 repair or replacement of any defective or nonconforming part or product or 2 a credit and or refund of the original selling price GF HEALTH PRODUCTS INC S SOLE OBLIGATION AND YOUR EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR REPLACEMENT CREDIT AND OR REFUND This warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to the manufacturer For warranty service please contact the authorized distributor from whom you acquired your GF Hea
Download Pdf Manuals
Related Search
Related Contents
Modèle de BAIL PROFESSIONNEL Manuale Utente di Avigilon Control Center Client Anleitungen - ALAN ELECTRONICS GmbH Page 1 МІЖРЕГІОНАЛЬНА АКАДЕМІЯ УПРАВЛІННЯ CARILLON 4 : 3 – CARILLON 16 : 9 – CARILLON CLASSIC ComposiGrip 01104F Instructions / Assembly Hubbell Electric Heater Company HSE Water Heater User Manual PM1703M-GN Software User guide KAM Karl Fischer Measuring water Copyright © All rights reserved.
Failed to retrieve file