Home

DME-A

image

Contents

1. The DME A offers an intuitive user interface which provides quick access to the station parameters Station Lock PIN required for unlocking Power indicator Shows the power delivered for each port Station Information Help for each parameter Si Power 45 eN 17 14 Selected 350 Se Simultaneous control of ports MENU gt C245 003 Cartridge in use Introduce the reference for more precise temperatures readings Tool in use Press here to see the Ports Screen See the information of all ports in real time when pressing the tool image from the Work screen Defined cartridge If not displayed go to Cartridge adjustment in Tools menu Tool Status Tip temperature Sleep or Hibernation 17 14 T210 Cartridge C210 001 STORE DR560 Cartridge C560 001 Sleep Tool in the stand 180 C Sliding bar See up to 4 ports Tool port Press any port for being displayed in the Work Screen Menu Screen Select any option and press the station information button to display each parameter description Adjust tool settings for each port Personalize the station Station name PIN activation Screen settings Robot activation Partial resets Station OO OO Utilities Utilities Tools D 1 Info Peripherals N Language Counters 9 Multi language 7 Join station ports with modules and
2. 0 840 F ro lt A Soa Idle Temp Stability still air 1 5 C 3 F lt uw u Ok Ambient Operating Temperature 10 40 C 50 104 F ng 5 5 O Q Tip to ground resistance lt 2 ohms a a Pod Tip to ground voltage lt 2mV RMS vi O D USB A USB B Peripherals connectors of Ta RJ12 connectors 1 for Robot and 1 for PSE Power Supply Control Unit a S RJ45 connector for LAN Ethernet O x X OMO Complies with CE standards lt SS n ESD protected housing skin effect ui SW Q S LL Q lt LU gt O me e gt gt gt ie i gt MN MO Nic O O III w NO I I I O LU LU LU O 222 NONA 18 19 E Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In accordance with the European directive 2002 96 EC electronic equipment at the end of their life men must be collected and returned to an authorized recycling facility www jbctools com 0012837 1114
3. Thermal Tweezers Micro Desoldering Iron Desoldering Iron Ref PA120 Ref HT 420 Ref DS360 Ref DR560 C120 C420 C360 C560 Peripherals By pressing Peripherals in the main MENU you can join tool ports with peripherals OQ which means each tool can work with 1 module and 1 pedal at the same time Q Control Unit Electric Pneumatic Nitrogen Flow Fume Extractor Desoldering Desoldering Regulator Switch Module Module Ref MNE A Ref FSE A Ref MSE A Ref MVE A Pedal Ref P 005 Function Enable disable the module or make any tool enter Sleep or Hibernation modes This pedal will work with any module or tool regardless of the module to which it is connected If you do not have a module you can link up the P 305 Pedal Kit to the tool port Compatibility o Si Select the equipment that best suit your soldering or desoldering needs www joctools com Basic working system Peripherals Control Unit DME Stand Tool pa pe MNE FSE P 005 T210 C210 O AD SD T245 C245 O T470 C245 DN SD T245 NA C245 AP SD AP130 A C130 O PA SD PA120 C120 HT SD HT420 C420 O DS SD DS360 C360 DR SD DR560 C560 The MNE Nitrogen Flow Regulator is required If you need to connect the MS MV MN or FS modules an adapter is required Ref IM2496 P 305 Pedal Kit By using the Connection Box the P 005 Peda
4. d vv Indicates there is a peripheral to be installed 10 11 o i www joctools com Process analysis Soldering Network Optimize your production after analysing the information provided by the graphics Remotely manage and monitor as many stations as your PC can handle By pressing Graphics in the Utilities MENU temperature and power figures in real 1 Download the JBC Manager software and the user manual from www jbctools com manager html time are displayed for each port This helos you decide how to adjust your process 2 Connect the stations via USB B or LAN RJ45 and the PC will automatically detect them or which tip to use to obtain the best quality soldering 3 The icon will appear on the screen Graphics Functions Set all the station parameters from your PC Change port Power JBC Manager software Temperature U e 50 E pi Temp H p1 Power 5 sec div Organize groups of stations and set all their parameters at the same time Store specific configurations for later uses Analyze the soldering graphics of the stations on your PC and export them Export graphics Insert a USB flash drive into the USB A connector to start saving your soldering LAN Hub USB Hub Io Didi any JBC station process in csv format 12 13 Increase x4 your DME s possibilities Centralize control of 3 PSE Power Supply units in a si
5. e station is turned off Handle with care including when adjusting the stand position Do not leave the appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Use a non residue classified flux and avoid contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protective glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved Children must not play with the appliance Maintenance must not be carried out by children unless supervised 16 17 o Si www joctools com Specifications Exploded View pra LE DME 1A 120V 50 60Hz Input fuse GA Output 23 5V 2 8858 5 DME 2A 230V 50 60Hz Input fuse 3 15A Output 23 5V ESES www NNW DME 9A 100V 50 60Hz Input fuse 8A Output 23 5V 2 EPP 555 Weight 4 3 Kg 9 3 Ib n gt 333 Dimensions 148 x 120 x 232 mm eS 4 l sa Output Peak Power 160W per tool a a amp Du Temperature Range 90 450 C 19
6. l will work with only the tool port to which it is connected Function Makes the tool enter skip from Sleep mode Connection Box Tool port connection Pedal Ref P 005 Operation The JBC Exclusive Heating System Our revolutionary technology is able to recover tip temperature extremely quickly It means the user can work at a lower temperature and improve the quality of soldering The tip temperature is further reduced thanks to the Sleep and Hibernation modes which increase the tip life by 5 1 Work su x 2 Sleep When the tool is lifted from the stand the tip will heat up to the When the tool is in the stand the temperature falls to 180 C 360 F preset sleep temperature selected temperature 17 14 E MENU 17 14 MENU gt C245 003 Sleep Tool in the stand Actual Temp 180 C Delay to hibernation 29 30 Selected 350 Port 3 Tools Menu Tools Menu Adjust temperature and cartridge Set temperature levels Set Sleep temperature Set Sleep delay from 0 to 9 min or no Sleep 3 Hibernation Long time in the stand After longer periods of inactivity pre set to 30 min the power is cut off and the tool cools down to room temperature 17 14 MENU Hibernation Actual Temp 25 C Tools Menu Set Hibernation delay from 0 to 60 min or no hibernation Work Screen o Ji www joctools com
7. ngle DME and work with as many as 16 tools simultaneously 1 Connect the DME to the PSE Control Units via the PS connector RJ12 2 Connect the others PSE control units as follows 4 Tools Control Unit Ref DME A Power Supply 4 Tools Units Ref PSE A 4 Tools 4 Tools 4 Tools o ES E www joctools com Working with Robots Manage and monitor the station using a Robotic system 1 Connect the tool to the station port by means of the Converter 2 Connect your Robot system to the station s Robot connector RJ12 DB9 RJ12 Adapater available on request Ref 0013772 3 Enable the Robot option in the station settings and the icon will appear 7 4 Set your Robot s commands according to the Robot Communication Protocol available on the website www jbctools com jbcsoftware menu 115 html Robot Converter b Ref 0002747 LIK f gt at Control Unit RS 232 connection Update the station software 1 Download the update file when available at 2 Insert the USB flash drive www jbctools com software html and The icon Ss is diplayed while updating save it on a USB flash drive Preferably one with no other files Update file 14 15 Maintenance Before carrying out maintenance or storage always allow the equipment to cool Clean the station screen with a glass cleaner or a damp cloth Use a damp cloth to clean the casing and the tool Alcohol can only be
8. o i E www joctools com English 4 Tools Control Unit Ref DME A Packing List The following items should be included 4 Tools Control Unit 1 unit Ref DME 1A 120V DME 2A 230V DME 9A 100V Power Cord nencen 1 unit Ref 0010569 230V 0013671 100 120V Manual 1 unit Ref 0012837 Features 3 5 Color TFT Touch screen Tilt the display for easy reading Speaker USB A connector o Si www joctools com Connections Work simultaneously with up to 4 tools and 1 module 1 pedal for each tool Peripherals Control Unit peewee ee ee ee 41 Fquipotential connection RJ45 connector for LAN SS e a a di USB B connector PERIPHERALS RJ12 connector for Robot Power Socket and fuse RJ12 connector for PSE Module cable Ref 0012709 Peripheral To another peripheral __ToPedal Ref P 005 Stands amp Tools For a basic working system you need 1 Stand 1 Tool and 1 Cartridge or tip Stands Ref AD SD Ref DN SD Ref AP SD Tools Precision General General Nitrogen Solder Feed Iron purpose purpose purpose Handle Ref AP130 Handle Handle HD Handle Ref 1245 NA Ref 1210 Ref 1245 Ref T470 The MNE Nitrogen Flow Regulator is f required Cartridges C210 C245 C130 J 7 o Si www joctools com Ref PA SD Ref HT SD Ref DS SD Ref DR SD Micro Tweezers
9. pedals Registers total and partial hours for each port work sleep hibernation Up to 8 languages to choose from Useful additional applications that complement and support your work Insert your tutorial Connect a O 9 a ee Video microscope via USB and see your work on the screen Recommended model Dino Lite AM2011 and equivalent _ Microscope er 2 lt r ah Catalog n L22 Files Calculator N Graphs Convert Unit Converter C F K Monitor and save your soldering process to optimize production Cartridge Adjustment more accurate temperature readings o Ji www joctools com 5 lt 17 14 a 4A T245 port 3 Cartridge Adjust C245 003 Temperature adjust 0 C Temp level set Off Sleep delay 0 min System notifications e USB flash drive is connected to the USB A Station is controlled by a PC Station is controlled by a robot The station is being updated by a USB flash drive The following icons may be displayed on the status bar on the screen Warning Insert the cartridge model and the station will recognize its characteristics size and shape to provide After connecting the tool introduce the last 3 reference numbers of the cartridge Press here for description Error Press here for failure description the type of error and how to procee
10. used to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes Replace a blown fuse as follows C 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever it off Clean periodically MENU lt 560 003 Temp Levels 350 2 Fuse holder 2 Press the new fuse into the fuse holder and replace it in the station Replace any defective or damaged pieces Use original JBC spare parts only Repairs should only be performed by a JBC authorized technical service o Si www joctools com Safety A It is imperative to follow safety guidelines to prevent electric shock injury fire or explosion Do not use the units for any purpose other than soldering or rework Incorrect use may cause fire The power cord must be plugged into approved bases Be sure that it is properly grounded before use When unplugging it hold the plug not the wire Do not work on electrically live parts The tool should be placed in the stand when not in use in order to activate the sleep mode The soldering tip the metal part of the tool and the stand may still be hot even when th

Download Pdf Manuals

image

Related Search

DME A dme aviation dme abbreviation dme academy dme airport dme acronym dme assam dme airport code dme arcs dme acronym medical dme antenna aircraft dme application dme academy basketball dme abbreviation healthcare dme abbreviation meaning dme aviation meaning dme academy sarasota dme academy daytona dme albuquerque nm dme augusta ga dme ann arbor dme austin tx dme ardmore ok dme academy daytona beach dme asheville nc dme academy florida

Related Contents

この度は、新日軽商品をご採用いただき誠にあけがとうございます。 商品  User manual visKeeper PC  manual de operação e instalação sistema analógico endereçável  5-Gallons (23 litres/liters) Manuel d`instructions  PROGRAMMABLE CONTROLLER FP  インターネットを利用する遠隔地テレビ−「まねきTV 事件」と「ロクラクⅡ  Rapport - Association des directeurs d`hôpital  Goldmund MIMESIS 24 User's Manual  guide sur la réservation de marché ou de lot(s)  Benutzerhandbuch MP118D - Physik Instrumente (PI)  