Home
Aeon Labs MultiSensor 6
Contents
1. AEON LABS Aeon Labs MultiSensor 6 Z wave MultiSensor Change history 1 9 23 2014 Initial draft 2 5 26 2015 Update 3 7 01 2015 Update 4 7 21 2015 Update V1 06 5 8 11 2015 Add more details for configuration parameters Aeon Labs MultiSensor 6 Engineering Specifications and Advanced Functions for Developers Aeon Labs MultiSensor is a routing binary sensor device based on Z Wave routing slave library V6 51 06 MultiSensor can be included and operated in any Z wave network with other Z wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network It also supports Security Command Class and has the AES 128 bit security encryption built right in While a Security enabled Controller is needed in order to fully use the security feature If the MultiSensor is included into a SIS or SUC Z wave network it will be associated to SIS or SUC automatically If PIR motion sensor is triggered the MultiSensor will send a Basic set OxFF to associated devices The PIR motion sensor will then become inactive After an interval time configurable the PIR motion sensor will wake up and can detect motion again The Multisensor will send basic set 0x00 if the PIR motion sensor is not triggered for the interval time configurable As soon as MultiSensor is removed from
2. n CE O T Version 501010000001 AA www aeotec com Screw hole Action Button Light Sensor Motion Sensor and UV Sensor RGB LED Battery cover Unlock Lock e 2 23 generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consul the dealer or an experienced radio TV technician for help Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available 22 Quick start Setup your power Your MultiSensor can be powered by battery or by USB with an appropriate adaptor For the purposes of installation and setup even if you intend to power your sensor with bat
3. 20 seconds Reset MultiSensor to factory Default 1 Press and hold the Action Button for 20 seconds 2 If holding time more than one second the LED will blink faster and faster If holding time more than 20 seconds the LED will be on for 2 seconds which indicates reset is success otherwise please repeat step 2 Note 1 This procedure should only be used when the primary controller is inoperable 2 Reset MultiSensor to factory default settings it will a let the MultiSensor to be excluded in Z Wave network b delete the Association setting power measure value Scene Configuration settings c restore the Configuration settings to the default 5 Special Rule of Each Command 5 1 Z Wave Plus Info Report Command Class Parameter Value Z Wave Plus Version 1 Role Type 6 ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON Node Type O ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE Installer Icon Type 0x0C07 ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY User Icon Type 0x0C07 ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY 5 2 Association Command Class MultiSensor supports 1 association group Group 1 is assigned to the Lifeline association group and can add max 5 association nodes When the PIR motion sensor is triggered the MultiSensor will send Basic Set OxFF to the associated nodes If no any PIR motion on an interval time configurable
4. If the exclusion is success MultiSensor s LED will blink slowly when you short press the Action Button If MultiSensor s LED still keeps on status in which you need to repeat the process from step 2 Short press 2 times within 1 second 1 Send Security Node Info frame 2 Add MultiSensor into z wave network 1 Power on MultiSensor The MultiSensor s LED will blink slowly when you short press the Action Button 2 Let the primary controller into inclusion mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the inclusion is success MultiSensor s LED will be kept turning on for 8 seconds when you short press the Action Button If the LED is still in slow blink in which you need to repeat the process from step 2 3 Remove MultiSensor from Z wave network 1 Power on MultiSensor The MultiSensor s LED will be kept turning on for 8 seconds when you short press the Action Button 2 Let the primary controller into exclusion mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the exclusion is success MultiSensor s LED will blink slowly when you short press the Action Button If MultiSensor s LED still keeps on status in which you need to repeat the process from step 2 Press and hold for 3 seconds Enable disable wake up for 10 minutes When it is enabled the orange Led will fast blink Press and hold for
5. Ultraviolet Sensor 1 Battery Sensor The table above shows a decimal representation of all flags that can be set on parameter 101 103 to report specific data Example use of the report table For example if you want to report only the temperature and light sensor you would add 32 64 and set the sum 96 to parameter 101 102 or 103 As another example if you want to report only the light sensor and battery you would add 1 128 then set the sum 129 to parameter 101 102 or 103 And if you want to report all of the sensors you would add the whole table together and set the sum 241 to parameter 101 102 or 103 Setting an automatic report interval 15 Parameter 3 2 byte decimal can be configured through your gateway in case the default settings of your MultiSensor are not what you desire For example this parameter setting is initially set to 240 which is the delay time in 4 minutes or 240 seconds You may set the value to the desired Motion Sensor delay time to any amount of seconds as you like So if you want the time out to be 5 minutes after the Motion Sensor is triggered set this parameter to the value of 300 Setting the sensitivity of your MultiSensor Parameter 6 1 byte decimal can be configured through your gateway in case the default settings of your MultiSensor are not what you desire For example this parameter setting is initially set to 127 which is the maximum sensitivity if you set it t
6. a z wave network it will restore itself into factory settings 1 Library and Command Classes 1 1 SDK 6 51 06 1 2 Library Basic Device Class BASIC_TYPE_ROUTING_SLAVE Generic Device class GENERIC_TYPE_ SENSOR_MULTILEVEL Specific Device Class SPECIFIC_TYPE_ ROUTING_MULTILEVEL_SENSOR 1 3 Commands Class Included Non Secure Included Secure Node Info Frame COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION V2 COMMAND_CLASS_POWERLEVEL V1 COMMAND_CLASS_NOTIFICATION_V3 COMMAND_CLASS_WAKE_UP V2 COMMAND_CLASS_BATTERY V1 COMMAND_CLASS_SENSOR_BINARY V1 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_CONFIGURATION V1 COMMAND_CLASS_ SECURITY V1 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_DEVICE_RESET LOCALLY COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_WAKE_UP V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC V2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 COMMAND_CLASS_MARK V1 Security COMMAND_CLASS_ZWAVEPLUS_INFO Command COMMAND_CLASS_ VERSION Supported Report COMMAND_CLASS_ MANUFACTURER SPECIFIC Frame COMMAND_CLASS_WAKE_UP COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_NOTIFICATION_V3 COMMAND_CLASS_BATTERY COMMAND_CLASS_SENSOR_BINARY COMMAND_CL
7. the MultiSensor will send Basic Set 0x00 to the associated nodes The automatically report of temperature humidity luminance and ultraviolet configurable also can be sent to associated nodes 5 3 Association Group Info Command Class 5 3 1 Association Group Info Report Command Class Profile General NA Profile MSB 0 Profile LSB 0 5 3 2 Association Group Name Report Command Class Group 1 Lifeline 5 3 3 Association Group Command List Report Command List Report 20 01 30 03 80 03 31 05 71 05 84 07 COMMAND_CLASS_BASIC BASIC_SET COMMAND_CLASS_SENSOR_BINARY SENSOR_BINARY_REPORT COMMAND_CLASS_BATTERY BATTERY_REPORT COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT COMMAND_CLASS_NOTIFICATION_V3 NOTIFICATION_REPORT_V3 COMMAND_CLASS_WAKE_UP WAKE_UP_NOTIFICATION 5 4 Manufacturer Specific Report Manufacturer ID 1 US EU AU 0x00 CN 0x01 Manufacturer ID 2 US EU AU 0x86 CN 0x6A Product Type ID 1 EU 0x00 US 0x01 AU 0x02 CN 0x1D 29 Product Type ID 2 0x03 Product ID 1 0x00 Product ID 2 0x64 100 5 6 Configuration Set Command Class Command Class COMMAND_CLASS_CONFIGURATION Command CONFIGURATION_SET Parameter Number Default Reserved Size Configuration Value 1 MSB Configuration Value 2 Configuration Value n LSB Parameter Number Definitions 8 bit 2 0x02 Enable Disable w
8. to reduce network traffic 0 disable 1 enable 41 0x29 Threshold change in temperature to induce an automatic report 20 Note 1 The unit is Fahrenheit for US version Celsius for EU AU version 2 The value contains one decimal point E g if the value is set to 20 the threshold value 2 0 C EU AU version or 2 0 F US version When the current temperature gap is more then 2 0 which will induce a temperature report to be sent out 42 Ox2A Threshold change in humidity to induce an automatic report 10 Note 1 The unit is 2 The default value is 10 which means that if the current humidity gap is more than 10 it will send out a humidity report 43 0x2B Threshold change in luminance to induce an automatic report 100 LUX 44 0x2C Threshold change in battery level to induce an automatic report Note 1 Theunitis 2 The default value is 10 which means that if the current battery level gap is more than 10 it will send out a battery report 10 45 0x2D Threshold change in ultraviolet to induce an automatic report 46 Ox2E Enable disable to send the alarm report of low temperature lt 15 C Value 0 disable Value 1 enable The MultiSensor will send a report of Multi Level Temperature CC to controller if the current temperature is less than 15 C Note The battery activity will be reduced at low temperatures 15 degrees Celsius and below which will le
9. ASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 2 Technical Specifications Operating distance Up to 500 feet 150 metres outdoors Operating temperature 0 C to 40 C Relative humidity 8 RH to 80 RH 3 Familiarize Yourself with Your MultiSensor 3 1 Interface Motion Sensor Action Button ra Light Sensor and UV Sensor Screw hole RGB LED Battery cover 4 All Functions of Each Trigger 4 1 Function of Z Wave Button Click one time 1 Send non security Node Info frame 2 Add MultiSensor into z wave network 1 Power on MultiSensor The MultiSensor s LED will blink slowly when you short press the Action Button 2 Let the primary controller into inclusion mode If you don t know how to do this refer to its manual 3 Press the Action Button Action Button If the LED is still in slow blink in which you need to repeat the process from step 2 Temperature Sensor Vibration Sensor 4 If the inclusion is success MultiSensor s LED will be kept turning on for 8 seconds when you short press the 3 Remove MultiSensor from Z wave network 1 Power on MultiSensor The MultiSensor s LED will be kept turning on for 8 seconds when you short press the Action Button 2 Let the primary controller into exclusion mode If you don t know how to do this refer to its manual 3 Press the Action Button 4
10. CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY 30 DAYS FROM AEON LABS S DELIVERY OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE FCC NOTICE for USA THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT STORE INDOORS WHEN NOT IN USE SUITABLE FOR DRY LOCATIONS DO NOT IMMERSE IN WATER NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment 21 Labs affiliates shareholders directors officers employees contractors agents and oth
11. EACH OF WARRANTY BREACH OF AGREEMENT OR EQUITABLE PRINCIPLES IS EXPRESSLY LIMITED TO AT AEON LABS OPTION REPLACEMENT OF OR REPAYMENT OF THE PURCHASE PRICE FOR 20 If your Z Stick is plugged into a gateway or a computer unplug it Take your Z Stick to your MultiSensor Press the Action Button on your Z Stick Press the Action Button on your MultiSensor You can test if your MultiSensor has been successfully included into your Z Wave network by pressing its Action Button If you press the button and your sensor s green LED is solid for a few seconds then inclusion has been successful If the green LED blinks when the button is pressed the inclusion has been unsuccessful and you should repeat the above steps 6 Press the Action Button on the Z Stick to return it to inclusion mode Return it to your gateway or computer AUN If you re using a Minimote Include 1 Take your Minimote to your MultiSensor 2 Press the Include button on your Minimote 3 Press the Action Button on your MultiSensor 4 You can test if your MultiSensor has been successfully included into your Z Wave network by pressing its Action Button If you press the Action Button and your sensor s green LED is solid for 5 a few seconds then inclusion has been successful If the green LED blinks when the button is pressed the inclusion has been unsuccessful and you should repeat the above steps 5 Press any button on your Minimote to
12. ad to the product may not work normally It is recommended to use USB power at low temperatures 100 0x64 Set 101 103 to default 101 0x65 Which report needs to be sent in Report group 1 See flags in table below 241 102 0x66 Which report needs to be sent in Report group 2 See flags in table below 103 0x67 Which report needs to be sent in Report group 3 See flags in table below 110 Ox6E Set 111 113 to default 111 Ox6F The interval time of sending reports in Report group 1 Valid values 0x05 0x28DE80 1 The unit of interval time is second if USB power 2 If battery power the minimum interval time is 60 minutes by default for example if the value is set to be more than 5 and less than 3600 the interval time is 60 minutes if the value is set to be more than 3600 and less than 7200 the interval time is 120 minutes You can also change the minimum interval time to 4 minutes via setting the interval value 3 bytes to 240 in Wake Up Interval Set cc 3600 seconds 112 0x70 The interval time of sending reports in Report group 2 Valid values 0x05 0x28DE80 Note 1 The unit of interval time is second if USB power 2 If battery power the minimum interval time is 60 minutes by default for example if the value is set to be more than 5 and less than 3600 the interval time is 60 minutes if the value is set to be more than 3600 and less than 7200 the i
13. aking up for 10 minutes when re power on battery mode the 0 MultiSensor 1 Value 0 disable 2 Value others enable 3 0x03 1 The default PIR time is 4 minutes The Multisensor will send BASIC SET CC 240 0x00 to the associated nodes if no motion is triggered again in 4 minutes 2 Range 1073600 Note 1 The time unit is second if the value range is in 10 to 255 2 If the value range is in 256 to 3600 the time unit will be minute and its value should follow the below rules a Interval time Value 60 if the interval time can be divided by 60 and without remainder b Interval time Value 60 1 if the interval time can be divided by 60 and has remainder 3 Other values will be ignored 4 0x04 Enable disable the function of motion sensor 5 1 Value 0 disable 2 Value 1 enable the current PIR sensitivity level 1 minimum level Value 2 enable the current PIR sensitivity level 2 Value 3 enable the current PIR sensitivity level 3 Value 4 enable the current PIR sensitivity level 4 Value 5 enable the current PIR sensitivity level 5 maximum level 5 0x05 Which command would be sent when the motion sensor triggered 1 1 Value 1 send Basic Set CC 2 Value 2 send Sensor Binary Report CC 39 0x27 Configure low battery value 20 Value 10 to 50 10 to 50 40 0x28 Enable disable the selective reporting only when measurements reach a certain 0 threshold or percentage set in 41 44 below This is used
14. alue measure value E g If measure value 80RH and the standard value 75RH so the calibration value 75RH 80RH 5RH OxFB If the measure value 85RH and the standard value 90RH so the calibration value 90RH 85RH 5RH 0x05 203 0xCB Luminance sensor calibration the available value range is 1000 1000 The calibration value standard value measure value E g If measure value 800Lux and the standard value 750Lux so the calibration value 750 800 50 OxFFCE If the measure value 850Lux and the standard value 900Lux so the calibration value 900 850 50 0x0032 204 OxCC Ultraviolet sensor calibration the available value range is 10 10 The calibration value standard value measure value E g If measure value 9 and the standard value 8 so the calibration value 8 9 1 OxFE If the measure value 7 and the standard value 9 so the calibration value 9 7 2 0x02 252 OxFC Enable disable Configuration Locked 0 disable 1 enable 255 OxFF Value 0x55555555 Default 1 Size 4 Reset to factory default setting and removed from the z wave network N A 2 Reset to factory default setting N A Configuration Values for Parameter 101 103 configuration Reserved Value 1 MSB configuration Reserved Value 2 configuration Reserved Value 3 configuration V
15. alue 4 LSB Luminance Humidity Temperature Ultraviolet Reserved Reserved Reserved Battery Reserved Reserved bits or bytes must be set to zero A AEOTEC MULTISENSOR 6 View the expanded manual http aeotec com support A S AEQTEC Aeotec by Aeon Labs MultiSensor Motion sensor Humidity sensor Thermometer Light sensor Ultraviolet sensor Vibration sensor The corner of your room just got smarter Aeotec by Aeon Labs MultiSensor looks like a motion sensor and it acts like one too But it s also so much more Installing this 1 piece of Z Wave technology is the same as installing 6 pieces of Z Wave technology Your home control network will immediately understand motion temperature humidity light Ultraviolet and Vibration readings wherever MultiSensor installed Those intelligent readings will equate to intelligence automation And intelligent automation will give you the perfect smart home Familiarize yourself with your MultiSensor Your MultiSensor comes packaged with a number of accessories that will help with its installation and operation Package Contents 1 MultiSensor 2 Battery Cover 3 Back Mount Arm 4 Double Sided Tape 5 Screws x2 6 Micro USB Cable Certifications regional Z Wave and Z Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in WAVE the United States and other countries E FCC ID XBAFT100
16. e Batteries naturally lose their charge over time Removing your MultiSensor from a Z Wave network Your MultiSensor can be removed from your Z Wave network at any time You ll need to use your Z Wave network s main controller to do this and the following instructions tell you how to do this using Aeotec by Aeon Labs Z Stick and Minimote controllers If you are using other products as your main Z Wave controller please refer to the part of their respective manuals that tells you how remove devices from your network 11 If you re using a Z Stick Action Button If your Z Stick is plugged into a gateway or a computer unplug it Take your Z Stick to your MultiSensor Press and hold the Action Button on your Z Stick for 3 seconds and then release 4 Press the Action Button on your MultiSensor 5 If your MultiSensor has been successfully removed from your network the RGB LED will be active with a colourful gradient for 3 seconds When you press the Action Button on the MultiSensor its green LED will blink If the removal was unsuccessful the green LED will stay solid for a few seconds when you press the Action Button 6 Press the Action Button on the Z Stick to take it out of removal mode w N gt If you re using a Minimote 1 Take your Minimote to your MultiSensor 2 Press the Remove Button on your Minimote 3 Press the Action Button on your MultiSensor 4 If your MultiSensor has been successfull
17. eet 150 metres outdoors Warranty Aeon Labs warrants to the original purchaser of Products that for the Warranty Period as defined below the Products will be free from material defects in materials and workmanship The foregoing warranty is subject to the proper installation operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer Warranty claims must be made by Customer in writing within thirty 30 days of the manifestation of a problem Aeon Labs sole obligation under the foregoing warranty is at Aeon Labs option to repair replace or correct any such defect that was present at the time of delivery or to remove the Products and to refund the purchase price to Customer Celling 3 metres x Ground 8 metres For wall mounting using the Back Mount Arm Ground For optimal performance your MultiSensor should NOT be mounted directly on or near metal framing or other large metallic objects Large metal objects may weaken the Z Wave wireless signal If selecting an outdoor location it s important to position your MultiSensor in a sheltered location It is best if your MultiSensor is not directly exposed to rain and is important that the humidity venting on your MultiSensor never is Physically install your MultiSensor With your MultiSensor now part of your Z Wave network it s time to finish its physical instal
18. er representatives harmless from all demands claims actions causes of action proceedings suits assessments losses damages liabilities settlements judgments fines penalties interest costs and expenses including fees and disbursements of counsel of every kind i based upon personal injury or death or injury to property to the extent any of the foregoing is proximately caused either by a defective product including strict liability in tort or by the negligent or willful acts or omissions of Customer or its officers employees subcontractors or agents and or ii arising from or relating to any actual or alleged infringement or misappropriation of any patent trademark mask work copyright trade secret or any actual or alleged violation of any other intellectual property rights arising from or in connection with the products except to the extent that such infringement exists as a result of Aeon Labs manufacturing processes IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT INCIDENTAL PUNITIVE SPECIAL OR CONSEQUENTIAL DAMAGES OR DAMAGES FOR LOSS OF PROFITS REVENUE OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY WHETHER IN AN ACTION IN CONTRACT OR TORT OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AEON LABS LIABILITY AND CUSTOMER S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS WHETHER BASED ON NEGLIGENCE STRICT LIABILITY BR
19. is press and hold its Action Button for 3 seconds and then release it Your MultiSensor s LED will fast blink for 10 minutes to indicate that it is active When you are done configuring or communicating with your MultiSensor you can put it back into sleep mode to conserve battery power To do this press and hold its Action button for 3 seconds and then release it Your MultiSensor s LED should now be off to indicate that it is asleep Tamper protection of your MultiSensor 16 USB port Battery Holder 3 Attach your desired mounting accessory This can be the Back Mount Arm You can affix the Back Mount Arm via using the provided KA2 5x20mm screws or Double Sided Tape Double Sided Tape Tips We suggest you choose the second method using screws to affix the Back Mount Arm would be more stable 4 After you have completed the affixing of Back Mount Arm you will need to lock the MultiSensor to the Back Mount Arm via turning the MultiSensor Screw hole 5 The Back Mount Arm may be locked at various angles by turning the Friction Lock clockwise and counter clockwise to respectively tighten or loosen the angle of the arm Setting automatic report flags Parameter 101 103 4 byte dec can be configured through your gateway in case the default settings of your MultiSensor are not what you desire Decimal Flag 128 Light Sensor 64 Humidity Sensor 32 Temperature Sensor 16
20. lation There are 2 ways that your MultiSensor can be mounted on on a wall or ceiling Using the Back Mount Plate you can mount it flat against a wall or ceiling Using the Back Mount Arm you can mount it on a surface or in a corner and angle it as desired To physically install your MultiSensor 1 Reattach the two parts of your MultiSensor to each other To do this align the lock unlock half dimple markers that are under the unlock symbol and then twist in a clockwise motion 2 If USB is used to power your MultiSensor ensure that power can be provided to your desired installation location Please note that when installed in areas that where the temperature can drop below 10 C it is advised that USB power is used and battery power is not 8 The MultiSensor contains a smart Vibration sensor in When someone attempts to disassemble your MultiSensor it can detect the vibration and send an alarm notification to the main controller and let you know Security or Non security feature of your MultiSensor in Z wave network If you want your MultiSensor as a non security device in your Z wave network you just need to press the Action Button once on MultiSensor when you use a controller gateway to add include your MultiSensor In order to take full advantage of all functionality the MultiSensor you may want your MultiSensor is a security device that uses secure encrypted message to communicate in Z wave network so a security e
21. nabled controller gateway is needed for the Multisensor to be used as a security device You need to press the MultiSensor s Action Button 2 times within 1 second when your security controller gateway starts the network inclusion Resetting your MultiSensor At some stage or your primary controller is missing or inoperable you may also wish to reset all of your MultiSensor s settings to their factory defaults To do this press and hold the Z Wave Button for 20 seconds and then release it Your MultiSensor will now be reset to its original settings and the LED will stay solid for 2 seconds and then turn off as a confirmation 17 Parameter 111 113 4 byte decimal can be configured through your gateway in case the default settings of your MultiSensor are not what you desire Parameter 111 will set the interval for Group 1 parameter 101 parameter 112 will set the interval for Group 2 parameter 102 and parameter 113 will set the interval for Group 3 parameter 103 As an example you have set parameter 101 to 241 which will report all of the sensors and you want to report it every 1800 seconds Set parameter 111 to 1800 to accomplish this Waking up your MultiSensor If your MultiSensor is battery powered you will need to ensure that it is active when configuring it To do this press the Action Button once which will trigger to send out a wake up notification command If you want it to wake up for 10 minutes to do th
22. ns shall void this warranty Excluded from the warranty are problems due to accidents acts of God civil or military authority civil disturbance war strikes fires other catastrophes misuse misapplication storage damage negligence electrical power problems or modification to the Products or its components Aeon Labs does not authorize any person or party to assume or create for it any other obligation or liability in connection with the Products except as set forth herein Aeon Labs will pass on to Customer all manufacturers Material warranties to the extent that they are transferable but will not independently warrant any Material Customer must prepay shipping and transportation charges for returned Products and insure the shipment or accept the risk of loss or damage during such shipment and transportation Aeon Labs will ship the repaired or replacement products to Customer freight prepaid Customer shall indemnify defend and hold Aeon Labs and Aeon 19 Technical specifications Model number ZW100 Power supply USB DC 5V or battery power 2xCR123A batteries 3V 1500mAh Operating temperature 0 C to 40 C 32 F to 104 F Measured temperature range 10 C to 50 C 14 F to 122 F Accuracy 1 C 1 8F Measured humidity range 20 RH to 90 RH Accuracy 3 RH at 25 C 77F Lighting 0 LUX to 30000 LUX Max motion sensitivity 5 metres Water proofing IP20 Operating distance Up to 492 f
23. nterval time is 120 minutes You can also change the minimum interval time to 4 minutes via setting the interval value 3 bytes to 240 in Wake Up Interval Set CC 3600 seconds 113 0x71 The interval time of sending reports in Report group 3 Valid values 0x05 0x28DE80 1 The unit of interval time is second if USB power 2 If battery power the minimum interval time is 60 minutes by default for example if the value is set to be more than 5 and less than 3600 the interval time is 60 minutes if the value is set to be more than 3600 and less than 7200 the interval time is 120 minutes You can also change the minimum interval time to 4 minutes via setting the interval value 3 bytes to 240 in Wake Up Interval Set CC 3600 seconds 201 0xC9 Temperature calibration the available value range is 100 100 or 10 0 C 10 C Note 1 The value contains one decimal point E g if the value is set to 20 the calibration value is 2 0 C EU AU version or 2 0 F US version 2 The calibration value standard value measure value E g If measure value 25 3 C and the standard value 23 2 C so the calibration value 23 2 C 25 3 C 2 1 C OxEB If the measure value 30 1 C and the standard value 33 2 C so the calibration value 33 2 C 30 1 C 3 1 C Ox1F 202 OxCA Humidity sensor calibration the available value range is 50 50 The calibration value standard v
24. o 64 the sensitivity will be the normal sensitivity If set it to 0 the sensitivity will be the minimum sensitivity Monitoring temperature humidity luminance and ultraviolet Your MultiSensor can report temperature humidity luminance and ultraviolet across a Z Wave network when requested If this function is supported by a controller generally a gateway the data will be displayed within its interface The specific Z Wave commands for the support of monitoring is the Multilevel Sensor Command Class Automatic reports are sent to association group 1 which is setup via the Association Command Class Please consult the controller s operation manual for specific instructions on setting your MultiSensor 14 Advanced functions Changing batteries Your MultiSensor has built in battery level detection It will automatically report its battery level to the associated controller gateway throughout its life until the battery is fully drained and needs replacing The battery status will often be displayed in the user interface of the controller gateway When used properly in an optimised Z Wave network your MultiSensor can be powered by batteries for 24 months before battery replacement is necessary Recommendation For networks which do not offer a method to display the battery level of your MultiSensor it is recommended that the sensor be tested occasionally to ensure that the batteries still hold enough charge to operat
25. return it to inclusion mode Selecting a location for your MultiSensor MultiSensor can bring its intelligent readings to many locations of your home which includes outside of your home Please note that when installed outdoors of your home your MultiSensor should only be relied on for temperature light humidity and ultraviolet readings where as the motion sensing capabilities should be disabled on your gateway in order to avoid false readings Light can impact on the quality of motion readings it s also important to understand environmental changes that may impact on other readings within your home Specifically your MultiSensor should not be installed in areas of artificial temperature change Thus when selecting a location avoid placing it beside or near air conditioners humidifiers and heaters and avoid positioning it directly opposite a window or direct sunlight Selecting a location for your MultiSensor to be installed depends on the use case Whatever the case or the installation location please ensure that it fits with your sensor s effective motion sensing range as described in these diagrams For ceiling mounting using the Back Mount Arm 6 The Warranty Period begins on the date the Products is delivered and continues for 12 months Any repairs under this warranty must be conducted by an authorized Aeon Labs service representative and under Aeon Labs RMA policy Any repairs conducted by unauthorized perso
26. teries we recommend utilizing the provided USB cable for setup For this you ll need an adaptor to plug your USB cable into this can include any USB port on a computer and most mobile phone chargers These steps can be performed in any location with your home and not necessarily in your MultiSensor s final installation location For a USB powered installation 1 Remove the Battery cover via sliding the Unlock button and separating the two parts of your sensor 2 Insert the appropriate end of the provided Micro USB cable into your sensor s USB port Your MultiSensor is now powered on 3 For a battery powered installation 1 Remove the rear part of your sensor as shown in the previous step 1 2 Insert CR123A batteries oriented according to the picture below Your MultiSensor is now powered on EA Secondary battery _ holder Primary battery holder Note If you just have only one CR123A battery please insert the battery into the primary battery holder Add your MultiSensor to your Z Wave network It s now time to sync your MultiSensor with a Z Wave network The following instructions explain how to do this using a Z Stick or a Minimote from Aeotec If you re using an alternative controller for your Z Wave network please refer to its user manual for network inclusion instructions If you re using a Z Stick Action Button THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED ALL
27. y removed from your network the RGB LED will be active with a colourful gradient for 3 seconds When you press the Action Button on the MultiSensor its green LED will blink If the removal was unsuccessful the green LED will stay solid for a few seconds when you press the Action Button 5 Press any button on your Minimote to take it out of removal mode Monitoring motion The MultiSensor can send Basic Set Command to association group 1 which is setup via the Association Command Class when the Motion Sensor detects movement to control the associated devices to OPEN state After 4 minutes by default if the Motion Sensor is not triggered again the MultiSensor will send Basic Set Command to these devices to set them to their CLOSE state However if the Motion Sensor is triggered again within 4 minutes the MultiSensor will reset the timing and start timing again The 4 minutes delay time can be changed through the usage of Z Wave commands built into Z Wave certified controllers gateways The specific Z Wave command supporting this function is Configuration Command Class Please consult the operation manual for these controllers gateways for specific instructions on configuringthe MultiSensor 13