Home
svex-171 user manual
Contents
1. The above color definition is limited to the attached cable when leave factory If user set himself check color definition again to avoid breakdown E Cable external diameter should match to seal rubber inner diameter Ensure seal rubber ring and cable seal rubber ring and lead in equipment interval reaches the demand of ex proof after tighten nut The demand of cable external diameter as following 3 The demand of cable external diameter size seal ring inner hole diameter Cable minimum diameter mm 4 Application 4 1 System Connection SVEX 2028E SVEX 171 Ex 4 2 Power on Foz Ss Press the switch lightly and the displayer enters the working condition The switch can be auto locked press it if half upspring condition is power on If whole upspring condition is power off 12 SVEX 171 Ex EX Monitor Ver 1 1 17 Power On Off switch position 5 Flameproof structure Completely consider the explosive air getting into ex proof structure which may lead to explosion because of some reason and to confirm and ensure camera explosion proof performance based on its structure gap length and max temperature it will get to Enclosure shall burden water pressure testing for 1 0Mpa for 10 12 seconds without leakage as pass which is ordered in GB3836 2 2000 Camera surface temperature max shall not over 80 C while it is working The lead to equipment is with the method of turn tigh
2. Ex mark ExdI BT6 DIP A21 TA T6 ATEX Certificate CNEXx06 1580 License XK06 123 00251 MANUAL BOOK Veilux SVEX 171 Explosion Proof Monitor www veilux net SVEX 171 Monitor Ver 1 1 A Safety Notes 1 Installation Please install under required environment Ensure stable and reliable mounting in case camera be damaged Ensure supply power same as nameplate marked before equipment being powered Do not open the flameproof joint and enclosure under humid atmosphere Because of excellent tightness of the equipment framing member may rusts after humid air enters flameproof humidity could not go outside Connect the cables correctly under the demand of manual book and press tighten nut 2 Maintenance Please shut off before maintenance and repair Pay attention to the flameproof joint while disassembly and assembly 3 Environmental protection The products contain spare parts which may pollute the environment for example PCB electric component plastic goods lubricating grease and so on Please collect and control the pollution sources when the equipment is maintained and scrapped Don t discard it but pass it to environmental department in case it will influence the environment www veilux net SVEX 171 Monitor Ver 1 1 A AAA e Renee E A AE renee ee eee ee rere en te ear 4 23 Tecnica Dalarnas caciones 4 A A ne idees 4 AS A a O calener as 5 20 A AEE E E E ET 5 2A Technical diluid
3. as is 5 ESA A EEE E es 6 20 ENVIO A AAA 6 AA Re ne Dan a ou 6 2 6 INA ATOM IZ se nm 7 SIMS MAI o eE 7 3 1 Desktop instalati Ohie 7 3 2 Wall Mount Installation 8 a O 8 JAC able Tre AMENER La ns nes 9 3 4 1 Use Ex proof Flexibility Tube 9 3 4 2 Connect power cable 10 3 4 3 Connect signal Cable o ccnooocccnocncconns 11 As PANIC AMON e ni ue 12 4 System CONE C OM nds 12 A NS O a dd Conan 12 Ds Flameprool Sica a les 13 6 TOUDIC SNOOUNG idx cs o lb 14 7 Shipment and storage 14 D CAO An ON 14 SA A O ea eee 14 www veilux net SVEX 171 Monitor Ver 1 1 1 Brief YHJ 171Ex proof displayer is new generation ex proof monitor equipment It changes the condition of terminal display equipment only be set in the control room It can offer the customers the clear monitor picture in the dangerous ex proof area At the same time it can enhance the flexibility of the system setting SVEX 151 adapts advanced manufacturing process With the help of mature quality the quality and function of products are leading position SVEX 151 Ex proof monitor has the characters of small in size light in weight convenient in shipment The various connections will make flexible application Strictly according to European Directive EC 94 9 and EN50014 Standards of GB3836 1 2000 GB3836 1 2000 Electrical apparatus for explosive atmosphere General requirements GB3836 2 2000 Electrical apparatus for
4. e it must be attached ex proof junction box when application Connect cable in the junction box The color of the cable is defined as following 10 SVEX 171 Ex EX Monitor www veilux net Ver 1 1 1 Power cable definition Name Power cable 3 4 3 Connect signal cable SVEX 171has two input ways and only one is supported when leave factory When use video input the product lead in a coaxial line It needs to avoid BNC pin When use VGA input SVEX 171lead in a VGA cable Standard VGA cable is 15 core screening cable Because of output RGB signal is weak it is easy to be influenced It is not suit to transfer foe a long distance A VGA pin will be made with the method of welding when application Please pay attention to the operational tools Professional soldering station is recommended to use Power off soldering iron when welding 1 5 6 10 11 15 K 15 15 contact pin D connector x 2 VGAcable definition color thick thick screening thick SENSE landing Signal line test landing 4 MEA A pr eee screening pa ee screening I camen screening po sv Brown 10 Logicliveline Red 11 Landing Yellow 12 In tandem data line SDA Orange Pan synchronization Tilt and A Jon Soon o 14 CVCLK for DDC Blue 15 66D Purple No 1 2 3 4 5 7 10 11 12 13 14 15 11 SVEX 171 Ex EX Monitor Ver 1 1 Notice gt
5. explosive atmosphere Flameproof d and GB12476 1 2000 Electrical apparatus for explosive dust Using enclosure and limiting surface temperature for protecting electrical apparatus Chapter 1 Technical requirements The housing is made of stainless steel Ib65 High quality LCD panel is installed inner monitor it can offer 1280 x1024 resolution ratio and display picture Quick response displays walking Graphic well TCO 03 keeps the highest safety and human engineering standards 2 Technical data 2 1 Type Code SV EX 171 Ex A Ex mark Design No Monitor Veilux www veilux net 2 2 Certificate Ex marking Ex Certificate ATEX Certificate 2 3 Electrical Input Voltage Consumed power Electric connection Power Signal input RGB imitate input Video input 2 4 Technical data Panel type area Pixel density Best resolution ratio Available area Color Tilt refresh rate Pan refresh rate Bandwidth Input impedance Video sync signal Input signal level SVEX 171 Monitor Ver 1 1 Exd IIBT6 DIP A21 TA T6 CNEx06 1580 XK06 123 00251 100 240VAC 50 60Hz 30 W typical value 3 core power cable Support only one when two methods appear 15 needles D SUB BNC pin TFT LCD Display 17 inch diagonal 0 264 x 0 264 mm 1280 x 1024 60Hz 337 9 x 270 3 mm 16 770 000 56Hz 76Hz 30KHz 83KHz 140MHz 750 22000 700mVp p Synchronization input signal Separate synchronization signal Compose s
6. lt 18 when wall mount installation 7 Wall mount installation 8 Lamp stand is fixed to the wall with bolt 3 3 Hoisting We can fix monitor bottom to the ceiling With the help of software overturn the picture with main engine Then hoisting is achieved SVEX 171 Ex EX Monitor www veilux net Ver 1 1 9 Lamp stand is fixed to the ceiling with bolt 10 Adjust screen angel when hoisting 3 4 Cable Treatment SVEX 171 Ex proof displayer is attached a power cable and a VGA signal cable or a coaxial cable Ensure the corresponding ex proof flexibility tube reach the demand of ex proof before leave factory 3 4 1 Use Ex proof Flexibility Tube a As Picture 11 turn on the tighten nut behind the back of the displayer Turn on the screw thread connector corresponding to ex proof flexibility tube SIR NES 11 b As picture 12 take down press tighten nut keep standard configuration gasket and rubber ring or use the spare parts Sheathe screw thread connector and ex proof flexibility tube SVEX 171 Ex EX Monitor www veilux net Ver 1 1 R a KR ME NA q pan ES 12 c As Picture 13 firstly turn tight the screw connection head and then tight the Ex proof Flexibility Tube 13 d As picture 14 the design sketch after installation 14 The design sketch after install ex proof flexibility 3 4 2 Connect power cable Power cable is a 3 core cabl
7. requires User un install the whole product by themselves Lightning or Act of God If there are additional agreements between Veilux and buyer then agreements shall be strictly done 9 Statement Veilux owns the final design changing and final specification rights and no 14 SVEX 171 Ex EX Monitor Ver 1 1 responsibility to inform user This manual book belongs to Veilux rights without permits or any book inform any company or private copy of whole or part of the book shall be prohibited VEILUX 802 GREENVIEW DR STE 200 GRAND PRAIRIE TX 75050 Website www veilux net E mail Sales veilux net Phone 1 800 510 6528 15
8. t the screw Window glass adopts steel glass to burden Impact and Heat change testing Window glass adopts steel glass to burden Impact and Heat change testing 17 LCD screen Front Panel LT Flameproof Tempered Glass Interface Base 18 Flameproof joint position picture 13 SVEX 171 Ex EX Monitor Ver 1 1 6 Trouble shooting Problems Reason memo Replace fuse Do it oneself Power off No image Check power line Do it oneself Signal line off Check signal line and pin Do it oneself Signal line broken Check signal line Do it oneself Interference Interference Look up interference source Do it oneself appears in the line double image Transfer distance is Signal transfer is less than Do it oneself too long 15 meters Pin connection is Display color is Check pin and receptacle Do it oneself not good unusual i Start software to adjust Software set wrong Do it oneself Resolution ratio Resolution ratio set Adjust Resolution ratio again Do it oneself is too low wrong 7 Shipment and storage After package without rain or snow fall directly to product shipment could do by air or sea and store for one year under the environment of 20 C 60 humidity gt 90 8 Guarantee For any camera produced by Veilux we promise a one year to repair warranty During Guarantee period we supply free service except following situations User does not operate as manual book
9. ynchronization signal Green signal Synchronization signal pole Plus minus pole Contrast corner peak value 180 www veilux net SVEX 171 Monitor Ver 1 1 2 5 Mechanical Protection IP65 Material 304 Weight 25Kg Dimension 395 H x 424 W x 200 D mm Len size 384 x 316 mm Glass thickness 12mm Inner cubage 3L Outlet hole quantity 2 Outlet hole screw thread size G 3 4 2 6 Environmental Air Pressure 86 106KPa Environment Temperature Working 0 C 40 C Storage 20 C 60 C Relative Humidity U95 RH 25 C 2 Dimension 1 SVEX 171 Ex proof displayer dimension SVEX 171 Ex EX Monitor www veilux net Ver 1 1 2 8 Installation Size 4 10 2 Displayer fixed hole 3 Installation 3 1 Desktop installation SVEX 171Ex proof displayer can be used corresponding to YHIC ex proof IPC It also can be used as a monitor to watch video signal It usually is set on the table directly Lamp stand is also fixed with bolt 3 Displayer can be set on the table directly 4 Fix the lamp stand with bolt Adjust screen angel according watching angel Screen can be adjusted Tilt 18 18 18 SVEX 171 Ex EX Monitor www veilux net Ver 1 1 5 Loosen two bolts to adjust 6 Adjust angel on tilt direction 3 2 Wall Mount Installation In some occasions we can use wall mount installation to save room If we adjust the combination of lamp stand we can achieve the aim Screen can be adjusted Ti
Download Pdf Manuals
Related Search
Related Contents
install gecs agent installation and maintenance instructions for compact unit 、耐エコ 取扱吉 明書 Amusement Park Scheduler SE-502 MANUAL GROUND-FAULT GROUND Bryant T6-NHP User's Manual NEC PF-51V21 User's Manual see manual Guide Utilisateur Copyright © All rights reserved.
Failed to retrieve file