Home

User Manual - PSA Products

image

Contents

1. If your dwelling is multi storey for minimum protection a smoke alarm should be fitted at the bottom of the staircase with further smoke alarms fitted on each upstairs landing This also includes basements See Figure 2 for examples NOTE For maximum protection a smoke alarm should be fitted in every room except kitchen bathroom and garage DO NOT FIT A SMOKE ALARM IN THE KITCHEN or BATHROOM as cooking fumes or steam may trigger the smoke alarm A Photoelectric smoke alarm may be located near the kitchen but not directly over the cooking area DO NOT FIT A SMOKE ALARM IN A GARAGE as exhaust fumes are likely to set it off POSITION THE SMOKE ALARM As smoke rises it is advisable to mount the smoke alarm on a ceiling in a central position Avoid areas where there is no air circulation Such as corners of rooms in the peak of an frame type of ceiling and air ducts used for heating and air conditioning If wall mounting do not mount tight into corners See Figure 3 for example Areas to be avoided include the following e Situations where the temperature may fall below 0 C or rise above 45 C e Humid areas such as bathrooms kitchens and shower rooms where the relative humidity may exceed 90 e Fume filled environments such as garages Exhaust gases may also cause false alarms e Adjacent to or directly above hot components such as radiators or wall vents that can affect the direction of air currents e In
2. PSA LIFESAVER PHOTOELECTRIC 9 VOLT BATTERY OPERATED SMOKE ALARM MANUAL MODELS LIFPE9 1 LIFPE9M K RON Z2 A P e MAIN FEATURES PHOTOELECTRIC SENSOR SUITABLE FOR SLOW SMOULDERING FIRES INSECT SCREEN SURROUND PE SENSOR SLIM LINE COMPACT SIZE MUTE amp ALARM TEST BUTTON LIFPE9M ALARM TEST BUTTON LIFPE9 1 LOW BATTERY WARNING SIGNAL MOUNTING SCREWS SUPPLIED COMPLIES amp APPROVED TO AUSTRALIAN STANDARD AS3786 LOUD 85dB ALARM This instruction leaflet contains important information on the correct installation and operation of your smoke alarm Please read all the information before commencing installation and retain for future reference SPECIFICATION Power Source 9V Battery Battery Type Eveready 1222 Energizer 522 Gold Peak 1604S Duracell MN 1604 Ultralife U9VL 0 C to 45 C 10 90 Operating Temp Ambient Humidity Alarm Sound Level 85 Decibels at 3 metres Battery Life 1 year minimum Tested amp Passed to AS3786 1993 LOCATING THE SMOKE ALARM This smoke alarm is a single station photoelectric alarm and should NOT be connected to other smoke alarms If your dwelling is a single storey for minimum protection you should fit a smoke alarm in the hallway between the living areas incl kitchens and sleeping areas Place it as near to the living areas as possible and ensure the smoke alarm is audible and can be heard when the bedrooms are occupied See Figure 1 for examples
3. The low battery beep will continue for at least 7 days or until the battery is replaced Use only those 9V batteries listed in the specification section of this manual These batteries can be purchased at your local retail outlet or supermarket Please use only specified batteries Use of different battery may have detrimental effect on operation It is recommend that smoke alarms to be replaced every 10 years MISSING BATTERY INDICATOR This smoke alarm will not operate without a fitted battery When the battery is removed from the smoke alarm a spring lever will rise in the battery compartment which will prevent the unit from being locked in place on the mounting plate IMPORTANT SAFEGUARDS Installation of your smoke alarm is only one step in your safety plan Other important steps should be taken to further improve your safety e Install the smoke alarm properly following this instruction leaflet e Test your smoke alarm weekly e Replace the battery immediately once depleted e Do not smoke in bed e Keep matches amp lighters away from children e Store flammable materials in a proper manner and never use them near naked flames or sparks e Maintain emergency equipment such as Fire Extinguishers Fire Blankets Escape Ladders etc and ensure all occupants know how to use them correctly e Plan an escape route s from your building in advance and ensure all occupants are aware of them Re enforce t
4. his awareness periodically throughout the year e Make sure escape routes remain free of any obstructions ALTHOUGH A SMOKE ALARM CAN HELP SAVE LIVES BY PROVIDING AN EARLY WARNING OF A FIRE IT IS NOTA SUBSTITUTE FOR PROPERTY INSURANCE OR LIFE INSURANCE OF ANY KIND APPROPRIATE INSURANCE COVER IS THE RESPONSIBILITY OF THE HOME OWNER THIS PRODUCT IS A SEALED UNIT AND CANNOT BE REPAIRED IF THE UNIT IS TAMPERED WITH IT WILL INVALIDATE THE WARRANTY IF THE UNIT IS FAULTY PLEASE RETURN IT WITH YOUR PROOF OF PURCHASE TO YOUR PLACE OF PURCHASE SMOKE ALARM WARRANTY PSA Products Pty Ltd warrants to the original purchaser each new smoke alarm to be free from defects in materials and workmanship under normal use and services for a period of two 2 years from the date of purchase The company will not be obligated to repair or replace parts which are found to be in need of repair or replace parts because of misuse damage or alterations incurred after date of purchase PSA Products Pty Ltd agrees to repair or replace at its option any defective smoke alarm provided that it is returned with proof of purchase and return postage prepaid to PSA Products Pty Ltd To the extent permitted by law the liability of PSA Products Pty Ltd arising from the sale of this smoke alarm or under the terms of this limited warranty shall not in any case exceed the cost of a replacement smoke alarm and subject to this clause in no case shall PSA P
5. rm in a clockwise direction until you hear 2 clicks The smoke alarm is now locked in position e Test the smoke alarm for correct operation using the test button facility TAMPER PROTECTION FEATURE To make the smoke alarm tamper protected a tamper resistant means has been provided To utilise this feature break off one of the tamper protection pins from the mounting plate and insert the pin in the hole on the side of the mounting bracket Using this feature will help deter children and others from removing the smoke alarm from the mounting plate The tamper protection pin will have to be removed in order to replace the battery Using a tool small screwdriver lever the pin away from the mounting plate and rotate the smoke alarm to release it from the mounting plate OPERATING YOUR SMOKE ALARM Once the smoke alarm has been installed a small red indicator light LED positioned under the test button will flash approximately every 30 seconds in normal operation If smoke is detected the unit will emit a loud pulsating alarm until the air is cleared The red LED will flash indicating an alarm condition ALARM SILENCER MUTE FEATURE The smoke alarm model LIFPE9M have the capability of temporarily disabling the alarm circuit for approximately 10 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the smoke alarm The smoke alarm is desensitized marginally by pushing
6. roducts Pty Ltd be liable for consequential loss or damages resulting from the failure of the smoke alarm or breach of this or any other warranty express or implied loss or damage caused by failure to abide by the instructions supplied in this user manual This warranty is an addition to and does not exclude the rights of consumers under the Australian Trade Practices Act 1974 or any other law which may not be excluded Register this product for warranty on line www psaproducts com au It is recommended that smoke alarms to be replaced every 10 years Another Quality Product by A PSA Products FIRE SECURITY INTERCOMS PSA Products Pty Ltd 17 Millicent Street Burwood Victoria 3125 Ph 03 9888 9889 Fax 03 9888 9993 E mail enquiry psaproducts com au Website www psaproducts com au WARNING DESIGN PATENT SMOKE ALARM MODELS LIFPE9 1 LIFPE9M ARE PRODUCTS DESIGNED BY PSA PRODUCTS PTY LTD THEY MUST NOT BE REPRODUCED OR COPIED LEGAL ACTION WILL BE TAKEN AGAINST ANY INFRINGEMENT
7. the MUTE TEST button on the smoke alarm The alarm will silence immediately and the red LED will flash approximately every 8 seconds for about 10 minutes to indicate the alarm is in the mute position The smoke alarm will automatically reset after approximately 10 minutes If after this period particles of combustion are still present the alarm will sound again The mute button can be used repeatedly until all the air has been cleared of the cause of the alarm NOTE Dense smoke will override the alarm silencer MUTE feature and sound a continuous alarm TESTING YOUR SMOKE ALARM It is recommended that you test your smoke alarm once a week to ensure the smoke alarm is working correctly Push and hold the test button for approximately 3 seconds A loud pulsating alarm should sound to indicate the correct function During the alarm the indicator light will flash quickly MAINTAINING YOUR SMOKE ALARM The smoke alarm is virtually maintenance free However periodically clean your smoke alarm to prevent dust build up This can be done by using a vacuum cleaner with the brush attachment Gently clean the front grill section and sides BATTERY REPLACEMENT The smoke alarm is powered by one 9V battery The battery should provide operation for at least one year under normal operating conditions If the smoke alarm emits a short beep once every 30 seconds the battery is at the end of its life and should be replaced immediately
8. very dusty or dirty environments such as workshops FIGURE 1 SINGLE STOREY DWELLING BEDROOM wc O LOUNGE ROOM KITCHEN FIGURE 2 MULTI STOREY DWELLING Smoke alarm for minimum protection O Smoke alarm for additional protection FIGURE 3 POSITION THE SMOKE ALARM CEILING 300mm min HEAT amp gt gt s SMOKE gt gt FROM gt a wa FIRE P BEST 5 8 HERE NEVER HERE 3 ACCEPTABLE HERE gt j SIDE WALL INSTALLING THE SMOKE ALARM This smoke alarm is powered by a battery and requires no additional wiring e A mounting plate is provided on the back of the smoke alarm e Remove the mounting plate from the back of the smoke alarm by holding the mounting plate and twisting the smoke alarm in the direction indicated by the OFF arrow on the smoke alarm cover e Having established the mounting location ensure that there is no electrical wiring or pipe work in the area adjacent to the mounting surface e Take the mounting bracket and mark two mounting hole locations e Drill holes in the positions marked e Insert the wall plugs into the drilled holes e Screw the mounting plate to the mounting surface DO NOT OVER TIGHTEN e Attach the battery to the connector clip and then place the battery as shown in the illustration in the compartment e Place the smoke alarm on the mounting plate and rotate the alarm until it connects into the mounting plate Twist the smoke ala

Download Pdf Manuals

image

Related Search

Related Contents

グラフィックスカード PG-VGA201 / PG-VGA201L 使用上の注意  Unitarian Universalist Church of Fresno  Genius 10450  Manuel d`utilisation Type 8905    Osram LIGHTIFY PAR16 TW    Manual de Instalación Referencia Técnica de Instalación.  Satellite Installation and User Manual  dossier d`Ivry ma ville du mois d`octobre - Ivry-sur  