Home

User manual 2.0 DOKOM CS

image

Contents

1. The readout data can be processed and displayed with DOKOM 5 or exported to further application programs Well known standard formats are supported configuration Microsoft Excel Microsoft Word Microsoft Excel Text Hich Text Comma Delmited T ext L54 Tab Delimited Data Interchange Format DIF STYLE Format Li SIEGE ta TOT 2 2 Requirements For the application of DOKOM CS the necessary cabling and meters are a prerequisite DOKOM needs the installation of the counters and the necessary wiring necessary for application The installed meters must be completely configured Before a readout of several meters can implemented each individual gt counter with an must be programmed with a M Bus Address That can be executed with the appropriate software When programming the meters care must be taken that each M Bus address is unique i e no address is used twice DOKOM supports the primary programmed M Bus devices within a search as well as the secondary addresses 2 3 Components DOKOM CS consists of three Software Modules DOKOM Configuration for adjustment of the meter as well as input of the necessary configuration details of the channels for readout It is also for the creation of user groups For test purposes an existing M Bus device can be readout in one of the module on one channel DOKOM Reading for the readout of the meters as well as for th
2. In the menu option Tools Select Station the desired station can be chosen By clicking on the station names and acknowledging this with the OK key the station is activated The current station and database can now be tested by moving the mouse pointer to the appropriate symbol 4 5 1 Setup of new Channels With the help of channels the necessary data can be entered for the communication between DOKOM and the readout meters There are some channels configured It is possible to add more channels if the required are not available Especially the readout through modem needs an individual channel and its setup If the required channel is available it is not necessary to go through this chapter Please use the scanning function to search for meters through that new channel Open the channel menu Dok om LS Conlin sten 4 21 CS Configuration Communication Groups I EL Name franare mem _ eng M uos IEEE Serial Mbus COM1 2400 8E1 Se Y es Serial Mbus COM1 300 8E1 Prir Yes Serial Mbus COM2 2400 8E1 Sees Serial Mbus COM2 300 8E1 Prir HandT rack COM1 19200 8N1 HandT rack COM2 19200 8N1 Ces handtrack new channel HandT rack Yes Actual station CLSt 1 CLSt1 The Name Description as well as the driver must be entered to create a new channel After clicking on the arrow in the driver box various drivers will be displayed for selection all driver
3. CS 59 5CNSUS METERING SYSTEMS User manual 2 0 Contents 0 INTRODUCTION 0 4 Wye 1 STATIONS CHANNELS AND USER GROUPS 1 4 1 STATIONS 1 4 1 3 USER GROUPS 1 6 2 AUTOMATIC READOUT OF METERS 2 7 1 DATA EVALUATION AND EXPORT 2 8 2 REQUIREMENTS 2 2 3 COMPONENTS 2 9 3 INSTALLATION OF DOKOM CS 3 10 99 1 UJ CONFIGURATION 4 13 4 1 AUTOMATIC CREATION OF DATABASE AND STATIONS 4 13 4 5 1 SETUP OF NEW CHANNELS 4 2 4 2 4 2 521 lt 6 4 5 6 LANGUAGE SELECTION 5 4 5 7 OPTIONS 5 5 READOUT 5 27 5 2 1 READOUT FOR BILLING 5 28 5 3 1 MONTHLY READOUT 5 33 6 USING MAPS 6 39 Ne Ne EXPORTING THE READOUT RESULTS 7 41 1 DATA EXPORT 7 41 2 EXPORTING GRAPHICS 7 46 S MRAPI MANAGER 8 49 5 1 HANDTRACK DRIVER 8 49 8 2 RS 232 DRIVER 8 5 5 3 MODEM MBUS DRIVER 8 8 8 4 SIMULATION HEAT AND WATER METERS 0 INDEX 9 1 0 INTRODUCTION 0 1 General DOKOM CS is a software solution that enables the readout of equipment with M Bus interface Primarily these devices are consumption meters e g water meters caloric meter or also electricity meters which are interrogated with the M Bus protocol The software can be used for the readout of individual M Bus devices and due to its modular structure is also adaptable for M Bus installations with hundreds of M Bus
4. D mah me 15 12142000 teste 94110108 T 0 5 30 5 2 5 Special Procedures Task schedule setup u 5 2 6 Mobile Readout 5 3 Procedure Replication 5 31 Task schedule setup ki x You can give a name to new task More informations about the task can be entered in the field Description Task kind denotes if the task wall read meters readouts or if it will do other job backup export M arme Task Description Task kind Check readout Logging readout Export readout results Special task Mobile readout L ancel Task schedule setup 21x E T TA 5 s 1 ee Hm KB SOUS e x E 18 00 00 00 O i June 2001 os ee Tue Wed Thu Fn Sat Sur A qr 1 a E n ee 4 5 6 7 8 8 10 mes 11 12 13 15 16 17 ES e218 19 20 22 23 24 EX 25 28 29 30 2 77772 1 11 More than one readout can be set which are then executed annually For example DOKOM can read the meter on the 2nd of April and also on the 18th of May It is important that in these cases the readout of the set dates only takes place on the specific dates that were set Task meters setup This task wall run vat Selected meters C Selected channel C Selected group C All meters v 1 Mame 2 3 Meter 1 Es Meter 5 44 4 a
5. 7 5 2 8 Logging Readout ET Logging readouts du All meters P 20 2 2001 10 41 36 Meter Po 20220001 1041 37 Meter2 95 25 20220001 10 41 39 Meter3 6 23022000 10 41 41 Meter4 212022001 104145 8 9 0 0 5 5 29 5 2 4 Readout for Export 472372001 10 52 46 Heather Nowhere Wa A MWh le BH Heather _ 4 23 2001 10 54 14 23 2001 10 54 47 Heather 4 23 2001 10 55 01 Heather UN H Created 2 21 2001 10 10 32 2 21 2001 10 10 52 hem Date Mame Serial number Counter 1 Value 1 lini 1 Counter Value Unit B 1 11562000 Zaher i mni Le 91 Ej 2 1262000 Zahler 1 111111111 HaEn 5E Wh Po TT kW BB 1156200 he 222222322 Wa 7E m3 AkDu 4 115200 Zahe3 30333333 En S Wh Enl Wh ZB 5 1152000 Zahler 4 44444444 Wo 18 30 116 2000 11111111 w 7TA Wh Le 3 7 20000 Ama 41 mh B 12 2000 Zahler amp 22222222 Wo 59 m3 5 Hz 1162000 mhe 33333333 En Wh 90 wh 10 115 2000 ZahlerB 44444444 115 2000 Zahir ii 12345500 Wo 2821113 42020 Wh 12 1152000 Zaher 12 197010000 kWh 20 IB 13 12 11 2000 Mater 2 100030000 HaEn Vo 1030 12 14 2000 SPX BATIDITZ Wa me m
6. 2 2400 1 Secondary scan Em Gr B Serial Mbus COIM 2 300 BET Primar ME CoG rack COM1 19200 8N 24 Single readout LOM2 19200 8N7 24 Single readout Now select the necessary channels in order to limit the meter search to the appropriate interfaces If you are of the opinion that all the meters have been found cancel the assistant to accelerate the process 4 14 Scan rar To stat of the push the button Start scan Dung fe scanning vou can skip actual geoup eth button Skip or pou can skip maring groups wath bution Skip a of the scan displayed in the bottom of the Simulation D 500 mz Vereemengqenzdhles 1H 1 11111111 Kaltwazserzahler 2H z 22222222 Simulation 107 105 500 ne BHandTrack The found meters are now added to the table It is now possible to display the meters in the appropriate channels Readout of an individual meter is possible by clicking Start in the meter window EMT T INN I E Wirda Help ORT Lanne lirzupr wo 5 X mij M h Lorch yan Cm ba B mel 3H 1313 Gazae 444443 sat station 4 3 Creating User Groups Meters that can be readout are now available in the meter list Later
7. set to 100 in each case then no readout results will be produced To this the simulated readout time can also be adjusted confirms the entered data Heter Setup i Electricity meter meter It is possible to set the meter type the serial number and the M Bus address This allows for the simulated meter to have all the characteristics of a real meter confirms the entered data Hrapi driver i Ir x Driver Help ay Extended functions Channel Setup 015 04 1000 ms Meter Setup Heat meter Beadout in progress Error type Hone Error Readout time 2 21 20 1 11 49 48 Serial number Number of counters 7 Counter l HeEn 48 MWh Counter 2 Pn 52 Counter 3 Vn 67 m3 Counter 4 AcFl 24 m3 h Counter 5 InTe Counter 6 OuTe 25 Counter 7 16 Readout results In the Readout Results window the following message appears Readout Running Under this message an increasing number of points are displayed as the readouts progress Directly after this the readout results of the selected meter are displayed By 8 13 clicking on the Details tab in this simulation no information is displayed After a successful readout the results will look similar to what is depicted here The menu point Further Functions is not functional with the HandTrack driver The readout results appear as follows
8. which can normally be found in the user manual must be entered As a prefix ATDT for the Tone dialup or either ATDF for Frequency dialup must be set This setting is reliant on the dialup of telephone connection The most widely used method is tone dialup The previously setup Suffix and Hang up command can be used The settings for the active and deactive connections can also be left as is The answer time Dial time time after a dialup attempt as well as the number of dialup attempts can individually and independently of the readout status be changed By clicking on OK the set values are enabled Gies Setup 101 501 mE ene Polus onic 2 EE SATIUS PolluCom 2 3 iv Wo iii e E Pollulom her vod SEINE 5434 5 P att D ud ix ae 2 EC ae 5 E PolluMUk E Power us 1 Cosmos Encoder cM nlet te dcn Cosmos Hyb Ele c a Date te et temperature Cosmas Hybrid 2 a E By clicking on Meter Settings the connected M Bus Device Meter can be selected and configured By scrolling through the devices the applicable device can be selected Next the M Bus address must be set Left picture If the M Bus address is not know by clicking on the Use secondary address check box then the identification takes place by means of the entered secondary address Right picture Mrapi driver Modem MBu
9. 00 00 00 00 00 m3 Vo E Vo 1 C AkDu mah l h C Ru Wo m3 wa 7 43 i DaokomCc 5H EZ Check Histosg 11111111 mmm ils XXYTETES mmm By pressing the table icon the readout results are displayed as table Here the order of the columns can be arranged Columns can also be hidden Thus a flexible format is provided to adapt to the intended application Serial number Counter 1 Value 1 Unit 1 Counter 2 Value 2 Init 7 44 Export configuration Microsoft Word Microsoft Word Microsoft E cel Test Hich Test Comma Delmited T ext Tab Delimited Data Interchange Format DIF STYLE Format TOs ory X Microsoft Excel exp1D3 xls ol 4 szd ulala fio fo fel ol ESSET EIER E 1 Benutzerauslesung 2 Created 24 6 2000 12 32 29 4 Item Datum Zeit 7 1 AkDu U AkDu MiDu U MiDu 19 Vo U Vo VoR U VoR 2 Name3 24 6 2000 12 25 Cosmos Hybrid 24 5 2000 12 20 Cosmos Hybrid 119 24 5 2000 12 15 Cosmos Hybrid Vh 25390 l h 1871
10. By clicking on Configuration the parameters of the RS232 connected periphery can be set The previously set values appear with the parameter of the MBus Centrals of type PW By clicking on OK the set values are enabled Counters Setup E Unknown NB 101 501 PalluSonic 2 4 PalluCom 2 5 4 4 PolluT herf 4 Dua JPolluMLIK E T PolluStat Cosmos Encoder Cosmos Hyb Ele J Cosmos Hybrid 2 By clicking on Meter Settings the connected M Bus Device Meter can be selected and configured By scrolling through the devices the applicable device can be selected Next the M Bus address must be set Left picture If the M Bus address is not know by clicking on the Use secondary address check box then the identification takes place by means of the entered secondary address Right picture Heter Setup FolluS onic 2 FolluCom FolluCom E PolluT herm Folli att Duo PolluStat Cosmos Encoder A _ _ The settings of the channel now appear at the top of the window as reference clicking on Start Readout the reading can be started Mrapi driver Seral Mbus SE driver In the Readout Results window the following message appears Readout Running Under this message an increasing number of points are displayed as the readouts progress Directly after this the readout results of the selected m
11. devices 0 2 Supported Readout Methods 0 2 1 Fixed Centralised Readout The data can be read in different ways DOKOM CS supports readouts with the help of a M Bus central Therefore registers which support the M Bus protocol can be readout over distances that may be up to several kilometres COSMOS HYBRID ENCODER ELECTRONIC 0 9 0 M Bus Repeater DOKOM PC SOFTWARE 0 2 2 Decentralised Station Headout If the readout distance is not sufficient then the meters can be connected by either wire connections telephone modem and or radio modem Also sub stations can be formed with larger systems DOKOM SOFTWARE DaAKnArtaA Repeater 0 2 3 Mobile Readout In addition the data can be processed with CS through either portable hand computers with manual data input inductive coupling or by radio transponders Funkmoaul Transponder Encoder MiniBus Verbindungskabel Connection Cable Zahlwerk Register Opto Encoder Manuelle Eingabe manuel entry L S ndgerat Handheld MDE Psion Workabout Manuel Entry Impulsgeber pulser Z hler mit mechanischem Z hlwerk Reed Meter with mechanical register 1 STATIONS CHANNELS AND USER GROUPS 1 1 Stations Core to the administration of the data in DOKOM CS is data bank structure DOKOM
12. in order to enable a simple readout of the meters a so called User Group can be created in which the desired meters can be added If necessary read more about this in the introductory section After clicking on File and then on User Groups or on the related symbol on the symbol list the User Group window will open a metere The user group can now be named To this additional data can entered e g place or position of the meters After input of the text the data will be acknowledged by clicking on the tick symbol By pushing on the plus key a new entry can be added By clicking on meters individual meters can be added Adding all counters of a channel can be executed by clicking on Add Channel Below is the screen to add individual meters Select meters for add Meter 8 Mater 2 Meter Mater 3 E tramzahler Meter 7 atramzahler a M W armemengenzahle pes 22 iMimemengenzihle After the selection of the user groups one can change to Readout By clicking on the satellite symbol DOKOM will start Reading Only if you need manual modification or different driver settings use the manual setup from the following chapter Usually you will continue with the Chapter Reading Dokom CS Configuration 4 17 4 4 Using Maps DOKOM CS enables the usage maps where the meters can be located To use these integrated graphical application it is nece
13. on the right will appear The type of meter can now be selected If several meters are installed on the Bus then the respective MB addresses must be entered secondary address should only be activated if more than 255 counters are attached to the Bus OK confirms the entered parameters he meter is now active writing is green Now the channel is successfully configured with the relevant By clicking the menu option Verify com group this can be checked If the examination should fail check the last few steps 4 5 5 Starting the Readout Now a readout can be executed by clicking on the Start the Readout tab 4 5 6 Language Selection Behind the menu option Tools is the menu point Language After clicking on the point a window appears with the available languages Select Language x 5 Cancel francais Portugu s 4 5 7 Options To change the name of the channel go to menu options Tools Options A window will open in which the names can be changed F Configuration 4 26 5 READOUT After completing configuration one can switch to the Readout program him L5 Lanne alinm 5 1 Scheduler The readout program screen will present itself as follows amp oko Ajoj By clicking on the clock symbol the option to enter readout procedures within the scheduler will appear It is possible to pre set readouts so that DOKOM runs these automat
14. the applicable to select it in the readout planer The readout procedure will then be stopped Thereafter the meter setup can be changed with Task Meter Setup Under Task schedule Setup the parameters of the procedure can be changed To activate the procedure once again the Enable Disable button must be pressed and change to Enable Incidentally with cancelled procedures it is possible to call up the online graphics and to activate it afterwards 6 USING MAPS When the maps have been configured at the DOKOM CS Configuration they can be used in Reading Mun de de EU LI Maga pt p7 RS E 2 a d Soe e EAE 1 mar Fa 8 Ge E ES 6 40 7 EXPORTING THE READOUT RESULTS 7 1 Data Export amp DokomCSR32 File Edt View Tools Window Help Export Wizard Ei Ei 2 Choose readouts to export data Station 001 Melnik Billing readouts Check readouts Check readouts history Load export definition fram file Export description Next gt k Cancel 7 44 Export Wizard E pork Wizard Ee Pousos Cosmo NP Misto Cosmo fJvPRousvic L NPRowovic Casts 7 42 Export Wizard 00
15. 001 Values 2 609995 2 38000t 16 7 1999 0 00 00 17 7 1999 0 00 00 18 7 1999 0 00 00 19 7 1999 0 00 00 20 7 1999 00000 21 7 1999 0 00 00 25 7 1999 0 00 00 26 7 1999 0 00 00 27 7 1998 0 00 00 s 28 7 1999 0 00 00 z 29 7 1999 0 000 m 7 15 1933 10 22 00 AM 2 130006 7 15 1933 10 28 00 2 150006 15 71333 07 50 00 29 7 1999 x 02 20 00 7 22 1999 7 26 54 PM 1 833 VP Misto Qokam m3 h 7 22 1988 7 26 54 PM 1 833 VP Misto Qokam m3 h Actual station 001 Melnik Trial version 2 1 Data Evaluation and Export The data can be represented both tabular and graphically amp DokomCSR32 P 11 23 2000 6 26 48 11 29 2000 6 26 47 _ 11 29 2000 6 26 50 11 29 2000 6 26 52 1 11 29 2000 6 26 54 _ 11 23 2000 6 26 56 1 11 29 2000 6 26 58 11 29 2000 6 27 00 j E 11 29 2000 6 27 02 eadout time E 11 29 2000 6 27 04 E 11 28 2000 6 27 06 11 29 2000 6 27 08 E 11 29 2000 6 27 12 E 11 29 2000 6 27 14 E 11 29 2000 6 27 18 1 11 29 2000 6 27 20 E 11 29 2000 6 27 22 11 29 2000 6 27 26 E 11 29 2000 6 27 35 E 11 29 2000 6 27 41 E 11 29 2000 6 27 44 111 29 2000 6 27 46 11 29 2000 6 27 48 11 29 2000 6 27 50 1 11 29 2000 6 27 56 29 11 2000 29 11 2000 29 11 2000 29 11 2000 17 50 00 29 11 2000 2941
16. 480 26260 1803 m3 119 23 6 2000 16 50 Cosmos Hybrid m3 119 m3 23 6 2000 16 45 Cosmos Hybrid 1799 m3 119 m3 23 6 2000 16 40 Cosmos Hybrid 1797 119 m3 23 6 2000 16 35 Cosmos Hybrid 1794 m3 119 m3 23 6 2000 16 20 Cosmos Hybrid 26480 l h 26560 l h 26260 l h 1788 m3 119 m3 23 6 2000 16 10 Cosmos Hybrid 26480 l h 26480 26260 l h 1783 m3 119 5330 Lh Lih ANZN Lik 4778 119 exp1D3 7 45 7 2 Exporting Graphics i DokomC5R32 File Edit View Tool Window Help Run readout chart wizard Chart Wizard 2 Choose readouts to create chart fram Station CE SET Billing readouts Check readouts history Load chart definition file Chart description Cancel Chart Wizard ki Ei You chart results only from one logging readout Choose logging readout to chart Logging readouts 7 46 Chart Wizard 0065 Nam2 BP teste Add meter ta selected meters Chart Wizard Lal rl Name2 9 7 47 151326 7 48 8 MRAPI MANAGER Manager 2 Bl x File View Tools Help Madem MBus Sernal Mbus Simulation With the MRAPI Manager it is possible to read a meter quickl
17. 9 Billing 1 4 2 5 5 25 Resoulution 3 8 Auftragsarten 5 24 Reading 0 4 1 3 2 5 2 7 3 6 3 10 4 16 4 19 4 22 5 24 5 25 5 26 5 27 5 28 5 30 5 31 5 32 5 33 5 34 User Readout 5 26 5 34 User Groups 1 3 1 4 4 12 4 15 4 16 Data evaluation and Export 2 6 Databank 1 3 4 12 4 17 4 18 Saving Data 6 8 Decentralised stationary readout 0 2 DOKOM 0 4 0 2 1 3 2 5 2 7 3 8 3 10 4 11 4 12 4 17 4 18 5 24 5 30 5 31 DOKOM Configuration 2 7 DOKOM Reading 2 7 Setting Meter Values 7 1 Hard disk 3 8 Channel 4 14 4 19 4 20 4 21 4 23 Channels 1 3 1 4 4 13 4 18 4 19 Communication Driver 3 10 INDEX Mouse 3 8 M Bus P 0 4 Mobile Readout 0 2 Modem Mbus Driver 7 3 MRAPI Manager 2 7 7 1 Planer 2 5 5 24 RS 232 Driver 7 3 RS232 4 18 4 19 4 21 Sammelstationen 4 17 Simulation 4 18 4 19 4 21 Simulation Heat and Water Meters 7 3 Saving 3 10 Special Procedures 5 28 Language 3 10 4 22 Station 1 3 4 12 4 17 4 18 Stations 1 3 Requirements 2 7 Meter 0 2 1 4 2 5 2 7 4 12 4 13 4 14 4 15 4 20 4 21 5 25 5 30 5 31 5 34 Central stationary readoutZentrale station re Auslesung 0 4
18. CS is also able to administer several data banks However in normal applications only one data bank is created Within this data bank one or more stations are created A station allows for adjustment to be made to the channel and the meter DOKOM CS Data base 1 Station 1 Generally the creation of one station is made for each computer For the mobile application where apartment blocks are to be readout it may be advisable to create a central on the laptop for each of the stations Then on location this station can easily be selected without any further adjustment DATA BASE STATION mA AD 1 Stations asa Erstellt NENNEN Mame Beschreibung Autor Must us o lol x Ma rh tm AA 9 Info Treiber Pe LN Ho Einstellung Zahlernerte Beschreibung Treiber DT REM EDS Einstellung Kanal Seral Mbus COM 2400 5i stat ERUIT SernalMbus COM1 300 Serial Mbus COM22400 851 563 Erweiterte Funklianen METERS Simulation 0 ms 18 Simulation 10 10 500 ms Ja EET 2 6 Eringa ien Ewa Cosmos Encoder 1 Cosmos Encoder 1H Ja Cosmos Encoder 1 Cosmos Encoder 1 Ja In the above picture one sees the structural build up of a database The Database created in the beginning conta
19. by telephone connection then one can summarize all these counters into a user group Each counter can be allocated easily to different user groups without any difficulty E g a consumption meter allocated to a user group which must be billed every month The same meter can also be placed in a user group which is read daily for reasons of leakage detection 2 AUTOMATIC READOUT OF METERS A so called scheduler controls the automatic readout of meters Into this scheduler the readout instructions are executed by DOKOM CS at the selected point in time The instructions can be automatically executed periodically e g annually within the space of several seconds The readouts can be created for different purposes As readouts for accounts and readouts for the examination of the meters and the system Additionally readout tasks can used to determine so called user readout instructions The readout results under Options Readouts can then automatically be exported as a file A further possibility exists within the datalogger function The meters can be readout and the results are displayed directly and on line DokomCSR32 Readout Chart Ex File Edit View Tools Window Help l x 9e sb om Bae Logging readouts Station 001 Smin 7 15 1999 7 54 00 7 15 1338 8 00 00 2 84999 7 15 1938 8 05 00 3 180001 2 20000t 2 07399 2 29999 2 920001 2 460001 2 660
20. e representation of on line graphics Additionally the readout data can be processed further in this module MRAPI manager for the administration of the different communication channels Depending on which driver is installed the meters can be readout over wire telephone radio or also with mobile readout devices 3 INSTALLATION OF DOKOM CS 3 1 System Requirements To use the DOKOM CS software these are the minimum requirements 200 MHz Pentium Computer or higher Windows 95 98 or ME Windows NT and Windows 2000 including higher versions Microsoft Internet Explorer 4 0 or above Serial Mouse Graphics card with a minimum resolution of 800 x 600 Pixels and 256 colours 32 Mbytes RAM 20 Mbytes of hard disk space Minimum of 1 free serial port 3 2 Installation 3 2 1 DOKOM CS with Windows 9X NT ME 2000 a L mmm LLL LLL DOKOM 5 is copy protected for legal reasons To the license a copy a protection plug Dongle has to be used with the program The plug is connected to the parallel interface Printer port LPT1 A printer can then be attached to the Dongle The plug connection should be secured by screwing it in The Dongle must also be attached with each new restart of the computer It is recommended that the plug reamain attached to the PC Start computer as usual Windows boot up Wi
21. eter are displayed By clicking on the Details tab information related to the transferred protocols can be viewed The readout results appear as follows 8 3 Modem Mbus Driver Mrapi driver After selecting the Modem MBus Driver the window above appears It is also possible here just like in the MRAPI Main menu to alter the meter values Before readout the 8 8 meter and the channel must be setup After clicking on the Channel Setup the following window appears Channel 4 vn ae eter request ep ELSA Microlink 33 67 Vv 1 xe Bausch Induline 14k4 before m iu MBus Modem Here the number of readout attempts after a failed readout as well as the time before and after the readout repetition can be set The COM Port can also be set and the number of the requested modem ieu port setup PONE DOLI ECTETUR et clicking on Configuration the of ie RS232 wem can be set which are necessary for the communication with the connected Modem Below the necessary settings are shown which are needed for communication with an M Bus modem By clicking on the set values are enabled s odem Setup Pref D By clicking on Modem the parameters for recognition of the connected modem must be set Below the settable parameters appear For recognition of the modem the required initialisation string
22. f DOKOM is the possibility to display readouts instantly in a graphical format In addition the appropriate function is available in the procedure scheduler The appropriate readout procedure is marked Afterwards the Quick chart key is enabled The key is also enabled when the readout is cancelled However the current readout procedure is then cancelled ag Scheduler Idle After the Quick chart key is pressed the graphical representation of all the meters within the readout procedure are shown The A tab must be pressed so that the graphics are constantly actualised pi RSS mnm pe Diem Fei BRA Par o Cabs HHEH i Su APER mmi i s o Es seme am SS ee HO Z0 PEG ee mono 5 37 5 5 Changing of Readout Procedures Scheduler Status 4 20 2001 12 30 00 Idle Start New task Remove task lask setup Task schedule Setup Quick chart Readout progress In order to change a running readout procedure it is necessary to select
23. h the RS 232 port can be set For communication with the HandTrack the parity and 8 2 the data flow control must be set to none The above depicted settings must also be set exactly as in the diagram By clicking on OK the settings are enabled Meter Setup EE Eind of transponde Impulse Serial number 0 A Counter name Quantity Volume Unit hd After clicking upon the Meter icon right next to the Channel symbol or either by selecting the menu options Driver and the Settings the above depicted screen appears Here one can choose between Transponder types Minibus or Impulse For direct readout of a particular meter the serial number of the meter can be entered The number of decimal places of the serial number corresponding to the meter can be filled by inserting zeros before the actual number The selection of the meter name can be entered in the next field The type and unit of the dependent Transponder and meter can be set in the next two fields With OK the entered data is saved and the main menu of the HandTrack appears Tm Drive Hep K ft E Meter Minibus 10 0 Unt m3 Baadnut in progres The settings for the Channel and the Meter now appear above in the window as a reference By clicking upon Start Readout the radio readout is commenced Mrapi driver In the Readout Results window the following message appears Readout Running Under this message a
24. i Remove Remove al Meters 5 3 1 Monthly Readout The same criteria apply the to the monthly readout as the yearly readout An intermediate reading can also be implemented here e g on the 15 of a month Frequently the question arises what is to be set if the readout is to take place on the last day of the month As it is know the months are different from one another DOKOM is able to interrogate its calendar so that if the date is entered as the 31 of April it will automatically read the meter on the 30 5 33 Task schedule setup 20 day 12 00 00 00 00 00 5 3 2 Weekly Headout With the weekly reading the readout day and the time can freely be chosen As with the other readings it is possible to have several readouts on different weekdays This can be useful e g when weekend consumption is to be dealt with separately 5 3 3 Daily Readout The same applies here as with the other readout methods Several readouts can also be set 5 34 Task schedule setup Monday 12 00 00 5 3 4 Periodic Readings With periodic readings the intervals between readings is set This type of the readout Is particularly suitable for the user readouts if for example for inspection purposes individual meters are to be readout very frequently for detailed investigation e g every 5 minutes Logger mode 5 35 Task schedule setup 00 00 00 23 59 59 5 4 Online Graphics One of the special features o
25. ically Several readout procedures can be entered so that these are later run simultaneously 5 2 Procedure Types 5 27 Different procedures which are independent of each other from each other can be entered Task schedule setup ki Ei You give a name to new task More informations about the task can be entered in the field Description Task kind denotes if the task will read meters readouts if it will do other job backup export Mame Task Description Task kind Check readout Logging readout Export readout results Special task Mobile readout Cancel 5 2 1 Readout for Billing By this it is understood that meters are to be read periodically to produce an account This type of the reading takes priority so that in the event of two readout procedures conflicting on a meter the readout is carried out successfully 27 Billing Readouts z He y 1 aE TE TOE lE 1 20 2000 4 32 5 AS Z hler 8 ST Yo 5 28 5 2 2 Readout for Verifying Check Readouts el x 4 TA 20 2 2001 10 36 22 Meter 00000 20220001 103623 20220001 10 36 25 000 33333333 2022001103626 Meter _ 44444444 20 2 2001 10 36 29 20 2 2001 10 36 31 20 2 2001 10 36 32 5 nt 20 2 2001 10 36 28
26. ins a station A station ID a name a description and a name of the author can be assigned to the station Then the accordingly created channels and the counters stored within it are assigned to this station After calling this station an immediate selection of M Bus devices can be readout without having to configure anything in the beginning 1 2 Channels DOKOM CS supports readout in various ways e g directly over an M Bus cable connection to the serial interface of the PC indirectly via a telephone modem radio transmission or mobile data collection These different ways are classified as channels For each of these channels a so called MRAPI driver must be installed in DOKOM CS The DOKOM software has MRAPI drivers for the support of all possible channels Telephone connection ig poop A e Mobile Data Accumulator User Groups 1 3 User Groups The transmission paths i e the channels do not necessarily show the allocation of the readout which the user wants Therefore it could be technically meaningful to connect electricity gas and water meters to one M Bus central If the user would like to select only the water meters then these should collectively be placed in one group for readout Such a group is called a user group The user group can be applied by distributing it over different channels E g if the counters of a separate billing customer are readout over a m bus central and others for reasons of distance
27. m3 25530 1870 m3 25530 1867 m3 119 se e ea sp i v ia f sape s ajo Inl 119 m3 5 24 6 2000 12 05 Cosmos Hybrid 1863 m3 119 6 24 6 2000 12 00 Cosmos Hybrid 1861 m3 119 3 24 2000 11 50 Cosmos Hybrid 1856 m3 119 3 8 24 2000 11 35 Cosmos Hybrid 1850 m3 119 3 9 23 6 2000 18 20 Cosmos Hybrid 1840 m3 119 10 23 6 2000 18 15 Cosmos Hybrid 1838 m3 119 m3 23 6 2000 18 10 Cosmos Hybrid m3 119 m3 23 5 2000 18 05 Cosmos Hybrid 1834 m3 119 m3 23 6 2000 18 00 Cosmos Hybrid 1831 m3 119 m3 23 6 2000 17 55 Cosmos Hybrid 1829 m3 119 23 6 2000 17 50 Cosmos Hybrid 26410 l h _ 26480 l h 26260 l h 1827 119 m3 23 6 2000 17 45 Cosmos Hybrid 26330 l h 26480 l h 26260 l h 1824 m3 119 23 6 2000 17 40 Cosmos Hybrid 26260 25410 l h 26180 l h 1823 m3 119 m3 23 6 2000 17 35 Cosmos Hybrid 26330 l h m3 119 m3 23 6 2000 17 30 Cosmos Hybrid 26330 l h 1819 m3 119 23 6 2000 17 15 Cosmos Hybrid 26410 l h 1812 119 23 6 2000 17 10 Cosmos Hybrid 26480 l h 1809 m3 119 m3 23 6 2000 17 00 Cosmos Hybrid 26410 l h 25480 l h 26330 1805 m3 119 23 6 2000 16 55 Cosmos Hybrid 26330 26
28. n increasing number of points are displayed as the readouts progress Directly after this the readout results of the selected meter are displayed By clicking on the Details tab the values of all other readout meters can be viewed alongside the selected meter The menu point Further Functions is not functional with the HandTrack driver The readout results appear as follows 8 2 RS 232 Driver 2 Mrapi driver Serial Mbus Driver Help Extended functions Channel Setup COM1 2400 SET San scan Meter Setup i Cosmos Encoder OH request pon Delay b before meter readout imd Delay b before repeated readout E Scanning meters methods 5 primary addresses secondary addresses After selecting the RS232 driver the following window appears It is also possible here just like in the MRAPI main menu to change the meter values Before the readout the channel and the meter must be set After clicking on Channel Settings the following window will appear Here the number of readout attempts after a failed readout as well as the time before and after the readout repetition can be set The COM Port can also be set and the Bus Master Initialisation enabled Serial port setup Ei x Data bit Stop Bi o Cas Data Flow Contro C parity Mark f C Odd C Space C Hardware Even C ONOFF
29. number of data bits belme repested readout 1000 Fs etc can be set there OK confirms the Scanning meter methods entered parameters F By primary addresses gt Th h tive writ siconda addresses e channel is now active writing is green 4 5 4 Setup of the Meter Meters can be generated and configured by clicking on the Meters tab The following window will open generated This opens the following window The descriptions of the 3 input fields appearing in the window can be changed under Tools Options Each counter is determined by input of these 3 points By pressing the key the entry is deleted and by pressing the key the entry is confirmed entries now appear in red writing in the table i e the meters are still deactivated activation of the meters differs again in the programming of the driver for the channel 4 5 4 1 Channel with Driver Simulation Heat and Water meter By pressing menu option Meter settings the window on the right will appear For the simulation either a hot or cold water meter can be selected Additionally each meter can be allocated an ID and a communication address This makes a mix up impossible during the representation of the values or in the on line graphics OK confirms the entered parameters he meter is now active writing is green 4 5 4 2 Channel with Driver RS232 M Bus By pressing menu option Meter settings the window
30. or users who are working with DOKOM CS for the first time it is recommended that you use the assistant This assistant is automatically started with the first start up of DOKOM A manual start of the assistant can be executed as follows otart the assistant by clicking on Assistant and afterwards on Assistant for the creation of a new station View Took woui Window SAF The meaning of the terms Station User groups are described in the introductory sections Hew station wizard All meters in Dokom database are are linked to the channels and they are linked to the stations Now you can add new station and it s channels to prepare for adding the meters Each station has it s unique name Enter the name of a new collecting station station Channels will be addes Groupe will be added by wizard recommended C will add them and setup them Previous Cancel Enter the desired name of the station After clicking on the Next tab a new station is created If you want to have the attached meters to be searched for automatically then use the assistant as depicted above 4 2 Automatic Meter Search Scan meters wizard 1 Simulation 0 2 0 500 me 2 Simulation 10 10 500 mg CI Em Gr 3 Seral Mbus 1 2400 SET Secondary scan Em Gr 4 Serial Mbus 300 861 Primary scan Em Gr 5 Seria Mbus
31. s Driver Help F H termin Channel Setup Beeb 78 COM1 2400 8E1 Friman scan Meter Setup Cosmos Hwb Ele FFFFFFFF FFFF FF FF Beadout in progress al 4 Readout results The settings for the Channel and the Meter now appear above in the window as a reference By clicking upon Start Readout the radio readout is commenced In the Readout Results window the following message appears Readout Running Under this message an increasing number of points are displayed as the readouts progress Directly after this the readout results of the selected meter are displayed By clicking on the Details tab the values of all other readout meters can be viewed alongside the selected meter The menu point Further Functions is not functional with the HandTrack driver The readout results appear as follows 8 4 Simulation Heat and Water Meters After selecting the simulation driver Water and heat meters the above screen appears It is also possible here just like in the MRAPI Main menu to alter the meter values When using this driver the preinstalled meters and channels are already made use of However these fields can individually be changed After clicking on Channel Settings the following window appears EL Mrapi diver Simulation Channel Setup The simulated meter error rate for the meter error and the readout error can be set here If these parameters
32. s English Furthermore it is assumed that there is a basic knowledge in using Windows If not then we recommend that this be done beforehand A suitable exercise program is contained within WINDOWS For further notes please refer to your system manual We will gladly assist you with any further queries Use our hotline in such cases The telephone numbers can be taken from the software registration Configuration of DOKOM CS an deem ir LI CA agmen 1 cime mi F b F ThE D oem LS brip See ete N um Lore LT masia e e ipa e 5 J Eip F uM Pho ia i i a Th F Fa eres 3 F SES mal C suec Rub i of Tri DE i Fa 7 hin Wet d an wer oig d E Fe riom tee Pan aedi x M E m a E After the successful installation of DOKOM CS a file with the name DOKOM CS32 is created in the program directory By clicking on Start Programs DOKOM 532 and then Configuration the configuration program of DOKOM is started 4 CONFIGURATION 4 1 Automatic Creation of Database and Stations F
33. s the available are displayed to the driver box By clicking the key the entered data is deleted with the key the data is added and saved In dependency of the desired driver the channel is activated as follows 4 5 2 Simulation Heat and Water meter With help of the simulation mode a readout can be realised without connecting a meter For the readout result a counter value is generated within a certain range To activate the channels the simulated rate of errors and the cyclic readout time must be entered These values can be entered by selecting Options Channel settings and entering the relevant information in the fields see picture to the right For ease of use the desired value can also be selected by pressing on the arrow symbol The error rate should not be equal to 100 otherwise no graph can be displayed OK confirms the entered data the 4 22 writing 15 green gt channel is now active writing in green 4 5 3 RS232 M Bus This driver supports communication with a M Bus central The central is connected with a serial cable to the PC The menu Zerg part rj option Settings Com group contains xo Details parameters for defining the Readout cycles Bus nitisizaion DTA and 2 dels and the time for the readout response Behind the menu point configuration the repast parameters can be set for serial Des mele readout m communication Parity
34. ssary to have a map of the location in an appropriated format e g BMP format Configuratio At first a new name is needed Then you can select a map out of your files Supported files bmp egf mif shp Opening the entry you add new meters to the map see the arrow Dokom CS Configurat 4 5 Manual Setup With individual installations the assistant can create special directory structures or they can be implemented manually CS Configuration File Tools Wizards Window Hep Ree e E For basic configuration it is necessary to activate the database and stations By clicking on Tools Database Selection a new database is created Select the appropriate directory where the data base information is to be found DOKOM can then access the data in the database After the database has been activated a new station must be created Under File Station the Collection station window will open Here the necessary data can be entered for the creation of the station The key deletes any entered data and the key confirms and replaces any data mos Oe 5s Sialion Mr nc I 1 Amr Carwerted han 15 bi datab 6229 1939 hom 16 bi darah citi 1611 Ci 2 Coie EEE 1513 dabond
35. thin Explorer select the executable file as the installation medium Execute the program with a double click Follow the instructions The setup program will create a new program group called DOKOM CS32 after a successful installation Now DOKOM as well as MRAPI and the M Bus driver managers have been installed onto the computer In order for the program to function properly it is necessary for entries to be made gt in the registry file With Windows NT systems the administrators rights must be freed up Please note that for the installation ask you system administrator to share the registry file and to deactivate any anti virus programs that may be operating With Windows NT it is recommended that after the installation of DOKOM CS all Service Packs be reinstalled 3 2 2 Loading of Extra Communications drivers If the readout to is to take place by telephone radio or something similar the appropriate drivers must be loaded We develope new drivers for other media and offer then through our web page There one can find if necessary new drivers for new applications or appropriate updates gt CS independently detects the language the installed Windows version If the English version is installed instead of the German Windows version then DOKOM starts in the English language The language can be manually changed at any time If the language of a Windows version is not supported then DOKOM automatically select
36. y and directly without starting the DOKOM application If the wanted type of meter is not at hand then one can click on the Tools Units to select the correct one One can also click on the Unit icon To the left of the Unit icon is the Globe icon By either clicking on this icon or by using Tools Language one can change the language at any time To start the wanted driver the icon can either be clicked upon or selected Icon will appear blue in colour and then the green arrow clicked 8 1 HandTrack Driver 2 Mrapi driver HandTrack Driver Help P a ER tea et 7 Channel Setup LOM 1 1 9200 87 24 Single readout Meter Setup Minibus 0 0 Beadout in progress 4 Channel Setup Serial port LOM Baud rate bps 19200 Details Customer code 24 A Double readout After selecting the HandTrack Driver the screen above appears To setup the parameters of a channel for readout of a meter with a HandTrack click upon Driver and then Channel Settings or click upon Channel icon This icon is the second from the right Here the corresponding COM Port address and the double readout function can be set A second reading automatically transfers the actual meter reading of the connected meter Thereby after the second readout one attains without a doubt the actual value of the counter After selecting the menu option Configuration the parameters of the communication wit

Download Pdf Manuals

image

Related Search

Related Contents

Manual de la Fuji X10  I giovani chiedono... Risposte pratiche alle loro domande, volume 1  MOUNTING INSTRUCTIONS  SAUTER CASE flexotron  2006-03-21 (1.9 Mo) - Commission des relations du travail  User Manual - Contemporary Controls  Data Exchange Manuel d`utilisation  Bedienungsanleitung Multi  Kawai CN31 Electronic Keyboard User Manual  Practical lab 1  

Copyright © All rights reserved.