Home

SMPS-T160

image

Contents

1. Describes the maximum load that the product an CEA can be exposed to in compression and ten sion This line also contains a reference to the WIO 0000 product s IP protection degree 5 Power Rate 100 240VAC 50 60 Hz 1 6A Input voltage for the product and maximum current consumption 6 Duty Cycle 10 max 2 min 18 min The duty cycle defines the maximum period during operation without interruption After operation a pause must be observed It is important that the operator follows the instructions of the duty cycle otherwise a possible overload may result in reduced product life errors 7 W O 0000 The LINAK work order followed by a unique sequential identification number Key to symbols The following symbols are used on the SMPS T160 label WEEE Directive 2002 96 EC Wheelie bin Compliance to all relevant EC directives By enean Australian EMC China Pollution control mark also indicates recyclability China RoHS legislation IEC 60417 5172 Class Il equipment Page 21 of 28 Ordering example SMPS T160 6 U 0 0 0 0 L Not used Fixed mains cable Output interface Bracket Input voltage Ingress protection Colour Variant Type Page 22 of 28 0 None 1 EU 3200mm 2 CH Japan 3200mm 3 UK 3200mm 4 UL 3200mm 5 Australia 3200mm 0 Standard 1 Hand control 0 None 1 Short 1008w1051 2 Long 1008w1052 U Universal 100V gt 240V 6 IP
2. fthe control box makes unusual noise or smells switch off the mains voltage immediately e Take care that the cables are not damaged e The product must only be used in an environment that corresponds to its IP protection Device protection The SMPS T160 contains several mechanisms to protect itself from being damaged due to exces sive use e n case of overheating the device will activate a thermal protection No power output will be available until the temperature is back again within normal operating range e ncase of exceeding the current limit failure in the actuator the device will activate an overload protection Immediately after the situation has been remediated the power output will be available again Hot plugging e tis not allowed to remove or to add the output cable as long as the SMPS T160 is powered by mains When the equipment is not in use e Switch off the mains supply in order to prevent unintentional operation e Check the SMPS and joints regularly for extraordinary wear Page 6 of 28 Important information Be aware of the following three symbols throughout the user manual Warning Failing to follow these instructions can cause accidents resulting in serious personal injury Recommendations No Failing to follow these instructions can result in the actuator suffering damage or being ruined Additional information Gi Usage tips or additional information that is important in connection with
3. EC EMC Directive 2006 95 EC Low Voltage Directive e EMC Standards EN 55014 1 2006 1 2009 2 2011 EN 55014 2 1997 1 2001 2 2008 EN 61000 3 2 2006 1 2009 2 2009 EN 61000 3 3 2013 e Safety Standards EN 61558 1 2005 1 2009 EN 61558 2 16 2009 A1 2013 Please be aware that the SMPS T160 has a lower duty cycle than the actuator This must be respected Page 15 of 28 Output e Nominal output voltage 29 V DC Vy e Ripple x500 mVp p e Total Output current 5 5 A at a duty cycle of 1096 Ton 2 minutes e Please be aware if connecting an external control to an SMPS configured with an output interface Hand control The unit connected should be capable of tolerating overvoltage caused by soft stopping actuators Overvoltage caused by soft stopping actuators can reach up to 38 V e Furthermore please be aware that the supply to control units are limited to 300 mA each System example Page 16 of 28 System combination possibilities SMPS T160 LA14 IC LA25 IC Bluetooth RF receiver HB40 receiver Signal cable Bluetooth receiver TR LMC2015 Compatible with iPhone 4S and up or Android MEME EU Market 868 3MHz US market 916 MHz TR TVPLRX868A02 TR TVPLRX916A02 LN NEM NNNM For more information please go to www linakthirdparty com Page 17 of 28 Cables The SMPS T160 is designed with exchangeable cables Note u e The signal and power cables must be ordered
4. the use of the actuator bo Recommendations e Only use the SMPS T160 within specified working limits e Do not place load on the SMPS T160 housing and do prevent impact or blows or any other form of stress to the housing e Ensure that the cable cover is mounted correctly Use 1 5Nm torque e Ensure that the duty cycle and the usage temperatures for the SMPS T160 are respected e Ensure that the cable cannot be squeezed pulled or subjected to any other stress Safety issues d The builder of the equipment shall ensure that the use of the component complies with relevant standards like the Machine Directive Care must be taken to avoid squeezing of cables as it can cause movement of the system The SMPS T160 must not be packed in heat insulating material but must be placed so that it can emit waste heat to the surroundings There are no ventilation holes to con sider the SMPS emits heat through its surface Page 7 of 28 Chapter 2 Mounting guidelines If the SMPS T160 comes with mains cable already mounted please go to step 4 2 Plug in the power cable 3 Screw the cable lock back on 4 Unscrew the cable lock 5 The 4 sockets give you 6 Remove the plugs accor 5 different connection ding to the number of possibilities Please see sockets needed table on page 9 Z 7 Plug in the cables 8 Screw the cable lock back on e Unused sockets must be sealed with a blind plug
5. 2 e t is recommended to shield the SMPS T160 from direct rain and sunlight to avoid overheating and wear and tear over time e When changing the cables on a LINAK SMPS T160 it is important that this is done carefully in order to protect the plugs and pins Please be sure that the plug is in the right location and fully pressed in before the cable lid is mounted e We recommend to take some precaution and design the wire connection in a way where the cable end is kept inside a closed protected area to guarantee the high IP protection Gi Different bracket types are available to know more please contact your local LINAK Supplier Page 8 of 28 SMPS T160 system possibilities Interface 1 Hand control 1 actuator 2 hand controls 2 actuators 1 Bluetooth RF receiver 1 alternative control 4 2 actuators 1 Bluetooth RF receiver 1 alternative control 4 1 actuator 1 Bluetooth RF receiver 1 alternative control 2 actuators Page 9 of 28 Actuator 1 Hand control 1 1A 1B 2A 2B 1A 1B 2A 2B 1A 1B 2A 2B 1A 1B 2A 2B 1A 1B 2A B 2 Electrical installation Output interface standard Connection diagram Fig 1 SMPST160 6UXOXO INWARDS OUTWARDS H Bridge FEEDBACK SIGNAL GND BLACK RED YELLOW Only available with IC Advanced GREEN VIOLET Depending on the actuator s feedback configuration WHITE Page 10 of 28 SMPS with standard outpu
6. 66 Dark Olivish Grey T160 160 W SMPS Switch mode power supply Chapter 5 Maintenance cleaning SMPS must be cleaned at regular intervals to remove dust and dirt and it must be in spected for mechanical damage wear and breaks e tis not allowed to spray directly with a high pressure cleaner on the device e nterconnecting cables must remain plugged in correctly fitted with O rings during cleaning to prevent ingress of water e Unused slots must be sealed by a blind plug e he SMPS T160 is resistant to the majority of cleaners and disinfectants However the deter gents must comply with the following basic requirements They must not be highly alkaline or acidic pH value 6 8 They must not contain caustic agents e All cables must be checked for wear and tear on a regular basis Any defect cables must be replaced Warning If irregularities are observed the SMPS T160 must be replaced Repair Only an authorised LINAK service centre should repair LINAK SMPS T160 Products to be repaired under warranty must be sent to an authorised LINAK service centre In order to avoid the risk of malfunction all SMPS T160 repairs must only be carried out by an authorised LINAK Service shop or repairer as special tools and parts must be used If a product is opened by unauthorised personel there is a risk that it may malfunction at a later date Main groups of disposal LINAK products may be disposed of possi
7. W Supply G R E E N Signal GND WH ITE Page 12 of 28 SMPS Hand Control version I O specifications Description The actuator is powered by the Signal Power signal SMPS and the signals are transferred to a signal cable if attached to the SMPS e Ke E g 5 o AC supply Red Extends the actuator For further information see the relevant I O specifications scheme Retracts the actuator in the actuator s user manual Supply Output 29 V DC 10 Yellow Supply Current limit 300 mA Overvoltage caused by soft stop ping actuator can reach 38 V Not to be connected White Signal GND For further information see the relevant I O specifications scheme in the actuator s user manual Page 13 of 28 Chapter 3 Troubleshooting No motor sound or No mains movement of the piston rod Wrongly connected signal cables for moving in and out Actuator stops or no 24 V DC power supply has been movement turned off Slow moving actuator The output power has been reduced due to high internal temperature No power for the The auxiliary power supply has hand control been cut off due to too high power consumption 2300 mA Page 14 of 28 e Check the AC supply e Change cable Check the signal wiring Outwards Red wire 24VDC Inwards Black wire 24VDC e Actuator has been overloaded gt 5 5 A e he actuator has exceeded the accepted duty cycle 210 e The power supply will auto
8. asia com www linak my NETHERLANDS LINAK Actuator Systems B V Phone 31 76 5 42 44 40 Fax 31 76 5 42 61 10 E mail infoGlinak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 E mail nzsales linak com au www linak co nz 35 387 634 6554 Republic Of Ireland Mobile E mail sales linak co uk www linak co uk IRAN Bod Inc Phone 98 2188998635 6 Fax 98 2188954481 E mail info bod ir www bod ir PERU Percy Martin Del Aguila Ubillus Phone 51 99 883 9879 RUSSIAN FEDERATION 000 FAM Phone 7 812 3319333 Fax 7 812 3271454 E mail purchase fam drive ru www fam drive ru SINGAPORE Servo Dynamics Pte Ltd Phone 65 6844 0288 Fax 65 6844 0070 E mail servodynamics servo com sg WWW Servo com sg SOUTH AFRICA Industrial Specialised Applications CC For contact details on other countries please visit www linak com or contact LINAK INTERNATIONAL Phone 45 73 15 15 15 Fax 45 74 45 90 10 Fax 45 73 15 16 13 Sales E mail info linak com www linak com Phone 27 11 312 2292 or 27 11 2077600 Switch Board Fax 27 11315 6999 E mail gartht isagroup co za WWW iSaza co za UNITED ARAB EMIRATES Mechatronics Phone 971 4 267 4311 Fax 971 4 267 4312 E mail mechtron emirates net ae www mechatronics ae USA LINAK U S Inc North and South American Headquarters Phone 1 502 253 5595 Fax 1 502 253 5596 E mail info linak us
9. bject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products Changes in installation and use of LINAK products systems can affect their operation and durability The products are not to be opened by unauthorised personnel The User Manual has been written based on our present technical knowledge We are constantly working on updating the information and we therefore reserve the right to carry out technical modi fications LINAK A S Page 4 of 28 LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or a new customer application LINAK products as defined above are applicable for a wide range of applications within the Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shall be responsible solely that LINAK products comply with the specif
10. bly by dividing them into different waste groups for recycling or combustion Metal scrap Cable scrap Electronic Plastic recycling or scrap combustion We recommend that our product is disassembled as much as possible at the disposal and that you try to recycle it Page 23 of 28 Warranty There is an 18 months warranty on TECHLINE products against manufacturing faults calculated from the production date of the individual products see label LINAK warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with Furthermore the SMPS T160 must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid For further details please see standard terms of sale and delivery for LINAK A S Page 24 of 28 Declaration of conformity LINAK WE IMPROVE YOUR LIFE DECLARATION OF CONFORMITY LINAK A S Smedevaenget 8 DK 6430 Nordborg hereby declares that LINAK Switch Mode Power Supply type SMPS T160 complies with the EMC Directive 2014 30 EU according to following standards EN 61000 6 1 2007 EN 61000 6 3 2007 complies with Low Voltage Directive 2014 35 EU according to the standard EN 61558 2 16 2009 complies with RoHS2 Directive 2011 65 EU according to the standard EN 50581 2012 Nordborg 2014 12 05 22 LINAK A S John Kling B Sc E E Certification and Regulatory Affairs Authorized to compile the
11. cn SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 3 8796 9777 Fax 61 3 8796 9778 E mail sales linak com au www linak com au AUSTRIA LINAK Reprasentanz Osterreich Wien Phone 43 1 890 7446 Fax 43 1 890 744615 E mail info linak de www linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 9 230 01 09 Fax 32 0 9 230 88 80 E mail info linak be www linak be BRAZIL LINAK Do Brasil Com rcio De Atuadores Ltda Phone 55 11 2832 7070 Fax 55 11 2832 7060 E mail info linak com br www linak com br CANADA LINAK Canada Inc Phone 1 502 253 5595 Fax 1 416 255 7720 E mail info linak ca www linak us com CZECH REPUBLIC LINAK C amp S S R O Phone 420581741814 Fax 420581702452 E mail ponizil linak cz www linak cz DISTRIBUTORS ARGENTINA Novotec Argentina SRL Phone 54 11 4303 8900 54 11 4303 8989 Fax 54 11 4032 0184 E mail info novotecargentina com WWW novotecargentina com AUSTRALIA Ballarat Industrial Supplies www ballind com au BL Shipways amp Co www blshipway com au Gas Strut Marine and Industrial www gasstrutmarine com au Prime Motion amp Control www primehyd com au West Vic Industrial Supplies www westvicindustrial com au COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memitda com co INDONESIA Pt Himalaya Everes
12. com www linak us com NORWAY LINAK Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail infoGlinak no www linak no POLAND LINAK Polska Phone 48 22 500 28 74 Fax 4 48 22 500 28 75 E mail dkreh linak dk www linak pl REPUBLIC OF KOREA LINAK Korea Ltd Phone 82 0 2 6231 1515 Fax 82 0 2 6231 1516 E mail scully linak kr www linak kr RUSSIAN FEDERATION 000 LINAK Phone 7 495 280 14 26 Fax 7 495 687 14 26 E mail info linak ru www linak ru SPAIN LINAK Actuadores S L u Phone 34 93 588 27 77 Fax 34 93 588 27 85 E mail linakact linak es www linak es SWEDEN LINAK Scandinavia AB Phone 46 8 732 20 00 Fax 46 8 732 20 50 E mail info linak se www linak se Terms of use SWITZERLAND LINAK AG Phone 41 43 388 31 88 Fax 41 43 388 31 87 E mail info linak ch www linak ch TAIWAN LINAK A S Taiwan Representative Office Phone 886 2 27290068 Fax 886 2 27290096 Mobile 886 989292100 E mail michael chen linak com tw www linak com tw TURKEY LINAK ith ihr San ve Tic A Phone 90 312 4726338 Fax 90 312 4726635 E mail infoGlinak com tr www linak com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date informati
13. either seperately or together with the actuator Colour Length Cable mm type Japan CH SML912066 PVG 3 0 75mm2 Black 3200 Straight Swiss Mains cables Plug types SML912099 AE 3200 SML912098 0 75mm2 3200 Straight angle Connection cable between SMPS and actuator Plug Colour Length Cable types mm type Minifit 1008w7200 PVC 18AWG Black 300 Straight 300 1500 Can be ordered seperately or mounted on LA14 LA25 Colour Length Cable mm type TECHLINE signal cables Plug types Flying 0367049 1500 PVC 20AWG Black 1500 Straight leads Flying 0367049 5000 20AWG 5000 leads The cable comes with an AMP connector that can be removed for flying leads Page 18 of 28 Dimensions Without brackets With short brackets Dann 10 nf Page 19 of 28 With long brackets D nt Page 20 of 28 Label for SMPS T160 LINAK 3 1 Item no SMPST160 6U0000 Sales and ordering code WE IMPROVE YOUR LIFE 2 Prod Date YYYY MM DD DENISE Production date describes when the product No SMPST160 6U0000 has been produced This date is the reference Prod Date 2014 11 05 for warranty claims Max Load 29VDC 5 5A IPX6 Class 2 power supply Power Rate 100 240V 50 60 Hz 1 6A fe 4 Max Load 29VDC 5 5 IPX6 Class 2 Duty 10 Max 2 18 min Cla lt power supply is r prebere Pica pp
14. ications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question Page 5 of 28 Chapter 1 Safety instructions AN Please read the following safety information carefully Ensure that all staff who are to connect mount or use the SMPS T160 are in possession of the necessary information and that they have access to this user manual Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product Before installation re installation or troubleshooting e Stop the application Switch off the power supply and pull out the mains plug e Relieve the application of any loads which may be released during the work Before start up e Make sure that the system has been installed as instructed in the User Manual e System connection The individual parts must be connected before the SMPS T160 is con nected to the mains During operation e Ensure that the cables are not damaged e Unplug the SMPS T160 before moving the equipment
15. mE TECHLINE IMPROVING FLEXIBILITY SMPS T160 LI NAK l To learn more about LINAK please visit WWW LINAK COM WE IMPROVE YOUR LIFE Page 2 of 28 Contents PIE deant 4 ENAK application DOG dpa d Usted 5 Chapter 1 eivai rade TION 6 NA arc Ras ROT 7 POCO MMR ICO ONS 7 SANE USS E S tes acto dessa pais sa nasa TET Bema UT 7 Chapter 2 MI QUIET cana ante NUR Ert 8 SMPSSTT6O system kick Audet ater bres tinte buit aetate uda iet edes 9 BISCUICACINS balla OM ME TET 10 Connection diagram and I O specifications SMPS with standard output Iriterface cr d eerta 10 11 Connection diagram and I O specifications SMES Hand dct Quen pea la 12 13 Chapter 3 TroublesHOOUlb G cies anro ROME RA e HEN M San Laon ae d esu cate D MU 14 Chapter 4 GCG A EE DRE E E E ELS 15 ENEI cv Pec HO HT EH 15 GUMU HL cM 16 DY SHOE SMI PENNE TET TT t DU UE 16 Systemicormbllsol actos atra ts Dh BR DS FO D BN OD aiunt 17 lo 18 C 19 20 Labebtor SMPS 21 KEV TO SYM DOE sc Acticin ethan ccm 21 ACHING CRAIC a Motu te eA LER UC s 22 Chapter 5 iainetahce cleanikl6 s aaa pcne oe ei aub D 23 AIME UU ES 23 lain grou
16. matically reengage after few minutes e Actuator is overloaded e he actuator has exceeded the accepted duty cycle 210 e he ambient temperature is too high Can be caused by direct sun light impact e The power supply will switch back to normal power when the temperature has dropped again e Check the control cables for short circuit e Too high current consumption in the control unit e he polyfuse will automatically reengage the power after a few minutes Chapter 4 Specifications e Nominal input voltage mains voltage 100 V AC 240 V AC 10 15 Universal input voltage e Nominal input frequency 50 Hz 60 Hz e Typical standby power consumption Approx 0 1 W e Housing colour Dark Olivish Grey e Protection class IP66 Usage e Compatibility LA14 IC A25 IC only 24 V DC e Duty Cycle 1096 2 minutes continuous use followed by 18 minutes not in use e Operating temperature 20 C to 40 C e Storage temperature 40 C to 70 C e Relative humidity 20 to 90 30 C not condensing e Atmospheric pressure 700 to 1060 hPa e Altitude Max 2000 metres above sea level e To extend retract the actuator A voltage greater than 21 V DC must be applied to red black wire To stop extending retracting the actuator A voltage less than 9 V DC must be applied to red black wire normally O V DC e Approvals The SMPS T160 is approved according to the following standards e 2004 108
17. on on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof please contact LINAK Copyright LINAK 2015 10 MA M9 02 564 C LINAK A S reserves the right to make technical alterations LINAK WE IMPROVE YOUR LIFE
18. ps Or disesala ato esed ooh actuals 23 Warani y better ome nae mene o dede pa textu uten 24 Decarauonm OF CONTO Y 25 Declaration of Incorporation of Partly Completed 26 PO ETT 28 Page 3 of 28 Preface Dear User We are delighted that you have chosen a product trom LINAK LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electric control boxes controls and chargers This user manual does not address the end user but is intended as a source of information for the manufacturer of the equipment or system only and it will tell you how to install use and maintain your LINAK electronics It is the responsibility of the manufacturer of the end use product to provide a User Manual where relevant safety information from this manual is passed on to the end user We are sure that your LINAK product system will give you many years of problem free operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is su
19. relevant technical documentation Original Declaration Page 25 of 28 LINAK WE IMPROVE YOUR LIFE DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY LINAK A S Smedevaenget 8 DK 6430 Nordborg Herewith declares that LINAK TECHLINE products as characterized by the following models and types Linear Actuators LA12 LA14 LA22 LA23 LA25 LA30 LA35 LA36 LA37 Power Supply SMPS T160 comply with the following parts of the Machinery Directive 2006 42 EC ANNEX Essential health and safety requirements relating to the design and construction of machinery 1 5 1 Electricity supply The relevant technical documentation is compiled in accordance with part B of Annex VII and that this documentation or part hereof will be transmitted by post or electronically to a reasoned request by the national authorities This partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of the Machinery Directive 2006 42 EC where appropriate Nordborg 2014 12 05 222 LINAK A S John Kling B Sc E E Certification and Regulatory Affairs Authorized to compile the relevant technical documentation Original Declaration Page 26 of 28 Page 27 of 28 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 755 8610 6656 Fax 86 755 8610 6990 E mail sales linak cn www linak
20. t Jaya Phone 6 221 544 8956 6 221 544 8965 Fax 6 221619 4658 6 221 619 1925 E mail hejplastic div centrin net id www hej co id DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fax 45 74 45 80 48 Fax 45 73 15 16 13 Sales E mail infoGlinak com www linak com DENMARK LINAK Danmark A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 841 8700 Fax 358 10 841 8729 E mail linak linak fi www linak fi FRANCE LINAK France E U R L Phone 33 0 2 41 36 34 34 Fax 33 0 2 41 36 35 00 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 6043 9655 0 Fax 49 6043 9655 60 E mail info linak de www linak de INDIA LINAK A S India Liaison Office Phone 91 120 4393335 Fax 91 120 4273708 E mail infoGlinak in www linak in IRELAND LINAK UK Limited Ireland Phone 44 0 121 544 2211 Fax 444 0 121 544 2552 44 0 796 855 1606 UK Mobile SLOVAKIA LINAK Slovakia s r o Phone 421 51 75 63 414 Fax 421 51 75 63 410 E mail jpGlinak sk www linak com ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail infoGlinak it www linak it JAPAN LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 E mail linak linak jp www linak jp MALAYSIA LINAK Actuators Sdn Bhd Phone 60 4 210 6500 Fax 60 4 226 8901 E mail infoGlinak
21. t interface I O specifications Input Output Description Green Yellow Violet The actuator is powered by the Signal Power signal SMPS and the signals are transferred to a signal cable if attached to the SMPS SMPS T160 AC supply Extends the actuator On off voltages Retracts the actuator gt 67 of 29 V DC Vin ON lt 33 of 29 V DC Vig OFF Input current 10 mA Endstop signal out Output voltage min 29 VDC Vin 1V Endstop signal in Source current max 100 mA Endstop signals are NOT potential free For further information see the relevant I O specifications scheme in the actuator s user manual Analogue feedback Hall Pot Configure any high low combination between 0 10V Single Hall output PNP Digital output feedback PWM amp oniigure any RIORUM the relevant specification s scheme in the actuator s user Analogue feedback 4 20 manual Configure any high low combination between 4 20 mA For further information see All absolute value feedbacks Hall Pot PWM and 4 20 mA Signal GND For further information see the relevant I O specification s scheme in the actuator s user manual Page 11 of 28 Output interface Hand control To be used when connecting with Bluetooth RF HB DP or flying leads Connection diagram Fig 2 SMPST160 6UX1X0 4 H INWARDS B LAC K T OUTWARDS R E D H Bridge Supply YELLO