Home

Emfit Safefloor - Safety Systems Distribution Ltd

image

Contents

1. DEVICE ON AND REMOVE THE AC ADAPTER CORD FROM X1 IF THE RED LED LIGHTS UP REPLACE THE BATTERIES WHEN THE AC ADAPTER IS CONNECTED TO THE POWER INPUT X1 THE BATTERIES WILL OPERATE AS BACK UP 10 LED Light indicators 1 Green LED Presence The green light starts blinking when the device notices movements on the sd sensor e 2 Blue LED Power ON Standby A m Pd gt 3 Red The blue light blinks slowly when the device is ON The blue light blinks fast for a short moment when the device triggers a notification 3 Red LED Fault The red light blinking quickly means the sensor is not connected or sensor is broken A notification sound is heard first time 10 seconds after device notices sensor fault and then after every 45 seconds Dry contact output gives notification first time after 30 seconds and then after every 30 minutes until proper sensor is plugged The red light blinking slowly means replace the batteries A notification sound is after every 1 2 hours and dry contact output gives low battery notification after every 3 hours until batteries are replaced 11 SW1 RESET SWITCH ON OFF SWITCH As Reset Switch When the notification sound is ongoing it can always be silenced by pressing the shortly the SW1 switch see picture In manual reset mode DIP switch 2 at OFF device must be reset by pressing shortly the SW1 switch Only after pressing the SW1 device is ready to make new notificati
2. LEAD TO A POTENTIALLY LIFE THREATENING SITUATION NEVER USE EMFIT SENSOR WITH OTHER MANUFACTURERS DEVICES THE NOTIFICATION MAY FAIL TO SOUND IF THE SENSOR OR ITS WIRE IS DAMAGED OR IMPROPERLY POSITIONED PETS CAN CAUSE FALSE NOTIFICATIONS SENSOR MUST NOT BE SCRATCHED SLIT OR CUT CHECK SENSOR AND WIRES CONDITION AND IN USE TIME AT LEAST WEEKLY AND REPLACE WHEN NECESSARY DO NOT INTEGRATE TO OTHER SYSTEM OTHERWISE THAN SPECIFIED IN THIS MANUAL DO NOT OPEN THE PARTS OR ATTEMPT TO REPAIR IT YOURSELF ALWAYS KEEP THE CONTROL UNIT AND SENSOR DRY EXPOSURE TO EXCESSIVE MOISTURE CAN CAUSE IT TO MALFUNCTION THE PRODUCT FULLFILLS THE REQUIREMENTS OF THE EMC DIRECTIVE FOR MEDICAL DEVICES IT DOES NOT CAUSE ANY ELECTROMAGNETIC DISTURBANCE IN NORMAL WORKING CONDITIONS THE PRODUCT CAN BE STACKED OR PLACED NEAR OTHER PRODUCTS OR DEVICES AS LONG AS MECHANICAL VIBRATION IS NOT PRESENT ALWAYS CHECK THE FUNCTION OF THE PRODUCT AFTER MAKING ADJUSTMENTS ACCIDENTIAL OR INTENTIONAL ADJUSTMENT OF KNOBS AND SWITCHES BY THE USER OR SUBJECT MAY CAUSE THE NOTIFICATION SOUND TO NOT ACTIVATE WHEN ADJUSTING THE VOLUME CONTROL SETTINGS TO THE OFF POSITION FALSE NOTIFICATIONS INCREASE OR MALFUCTION DECREASE WHEN ADJUSTING THE SENSITIVITY THE PRODUCT MAY NOT GIVE NOTIFICATION WHEN NECESSARY IF TURNED OFF BY PRESSING THE SW1 SWITCH THE PRODUCT MAY NOT GIVE NOTIFICATION WHEN NECESSARY WHEN SWITCHING DIP SWITCHES At the
3. S AND ITS U S SUBSIDIARY S CONTACT INFORMATION Manufacturer US Subsidiary Emfit Ltd Emfit Corp Konttisentie 8 10909 Van Owen St Suite 300 FI 40800 VAAJAKOSKI North Hollywood FINLAND CA 91605 USA Phone 818 508 6685 Fax 818 508 9413 Email sales us emfit com Phone 358 14 332 9000 Fax 358 14 332 9001 Email info emfit com Internet www emfit com Internet www emfit com 11
4. S s terrere a denos socer orae co ce e Free e FR ede ede vedy FE vun saaie hess Setting the Notification Sound Volume EN EI ennemi endum eese e eese e eese me enses e sene nene 4 SETTINGTHE SENSITIVITY i eseessa everest err pnr a ry Rea VERE EFE EY VE Ev Va eaa Ea a YR EVERY VN TV Ya YR EE EFE SEV ENNE Cnisia 5 INSTALLING THE FLOOR SENSOR nr sehn esee hehe esie tesis hes is esie isis esie edis esie esse e esiste is senses nenne nenne 6 CONNECTORS AND WIRING xar rrt RR TE AA A CX E cnn n i CERTO CX RO EXC TO ER FCU V ne a n s X2 AUD Connector PImn Orden rese rt ritu tR hte ert terrent ret nre ear a a aae netu ien nE a e ea Eu Eu Ere a eM ae Suae RR Eas 7 INSTALLING THE WALL MOUNT AND DEVICE INTO IT 0 cece enne emn hen he ie esiste she stesse senes nennen nn 8 INSTALLING BATTERIES AND BATTERY CONSUMPTION kr rina E E eee esa esse enses nnne 9 ABOUT THE OPTIONAL 5V AC ADAPTER ics cort eere a DUE KENT C ev vi tie ie eive ui o rk SE FOE CORE KE REX ER KE CORE C bXFEE Ne Vie r e Sie vr a 10s LED LIight iMG iGators oec E 11 SWI RESET SWITCH ON OFF SWITCH levies siecle eee ack E Ee aea eb ee eter CANC rea P E D AS On Off SWIEG Direct M 12 TESTING ANDSINSPEGTIONS 5 aea cdenssaat xag esi nest AEN aapa tiir NEA nay eats ri tene e aide chris mala anaa mia Day ras CER ICE T Ge IET RIA Dally INSPECtON Dee E E O E E EEE sails rete tene and re ee D
5. D VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT 19 CANADA EMC COMPATIBILITY STATEMENT This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num riqu de la classe A est conform la norme NMB 003 du Canada 20 EMFIT LIMITED WARRANTY STATEMENT In the unlikely event that your product needs guarantee service please contact your dealer distributor or manufacturer To avoid any unnecessary inconvenience on your part we recommend you read this instruction manual carefully before seeking guarantee service YOUR GUARANTEE By this Guarantee Emfit guarantees the product to be free from defects in materials and workmanship at the date of original purchase for a period of two 2 years from that date If within the guarantee period the product is determined to be defective at the date of original purchase due to improper materials or workmanship Emfit will without charge for labour or parts repair or at Emfit s discretion replace the product or its defective parts subject to the terms and limitations below Emfit may replace defective products or parts with new or refurbished products or parts All products and parts replaced become the property of Emfit TERMS Guarantee services will be provided only if the original invoice or sales receipt indicating the date of purchase model name and dealer s name is presented with the defective product within the guarantee period Emfit may refuse free of charg
6. EMEFIT safeFloor Bed and Door Exit Monitor User s Manual with Operation and Installation Instructions and Warranty Terms WARNING MUST NOT BE USED IN SITUATIONS WHERE A MALFUNCTION OR A LATENT DESIGN FLAW IN THE PRODUCT COULD LEAD TO A DELAY IN DELIVERY OF APPROPRIATE MEDICAL CARE OR THAT WOULD LIKELY LEAD TO A POTENTIALLY LIFE THREATENING SITUATION Applicable model numbers Control Unit D 1050 2G version t48 v1 0 2 Floor Sensor L 6090SL or L 60150 13 08 08 V1 2 t48 v1 0 2 Emfi Emfit and Emfit logo are either registered trademarks or trademarks of Emfit Ltd in EU USA Japan and or other countries Copyright 2002 2008 Emfit Ltd All rights reserved Patented patents pending List of patents is seen at manufacturer s website www emfit com 1 TABLE OF CONTENTS DANGER oy OTHER SYMBOLS USE D S 1 GENERAL INFORMATION eee te eere eeu eve ctr i vede e o i e tne ER EY EE 004 5044 s Ea U0 Ye vr ea E vi i v ie ee e te Rie a e E CER YE V NE EN TEKE NGA Macs Mur Control Unit eo no tac E EAA ean adit ad md E Ea aE T EEA ge tanta pa piece tie et eis E A Dine EOE REDE deje crinis TT TI xx EC E 2 PACKAGE CONTENTS Garaan aaa eqni e nssats sudare atn eterni cii eai ai SIR eR aie Bertie eee vie pieles at A a la ann d vs o crea ue n 3 BEFORE USE SELECT THE RIGHT DIP SWITCH SSETTINGS i eret eh eer hernia auo y eeu ree erue Y E ERR EXER SERRE Kk ER ERI CERE C TRO YES Table of DIP Switch Setting
7. NAL SAFETY AND ON THE OTHER HAND TO PROTECT THE DESCRIBED PRODUCT OR ATTACHED DEVICES FROM DAMAGE SAFETY NOTES AND WARNINGS FOR THE PREVENTION OF DANGER TO THE LIVES AND HEALTH OF USERS OR MAINTENANCE PERSONNEL AND OR FOR THE AVOIDANCE OF DAMAGE TO PROPERTY ARE EMPHASISED IN THESE INSTRUCTIONS BY THE PICTOGRAMS DEFINED HERE THE PICTOGRAMS USED HAVE THE FOLLOWING MEANINGS FOR THESE INSTRUCTIONS Means that death serious personal injury or substantial damage to property can occur if the appropriate precautionary measures are not taken Means important information about the product or a part of the instructions that particular attention should be paid to OTHER SYMBOLS USED Upper storage temperature limit All rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owner Our printed and electronically stored literature is purely advisory and therefore we bear no legal responsibility for the information provided We reserve the right to make changes and modifications without prior notification in the interest of continual improvements of our systems and components 1 GENERAL INFORMATION Intended Use The Emfit SafeFloor Bed and Door Exit Monitor device model D 1050 2G and sensor model L 6090SL or L 60150 is intended to be used for monitoring a bed or door exit and giving notification when person is stepping on the sensor The product consists of a floor sensor and a control
8. blinking same speed as blue light and sensor is connected sensor is broken Typically this due a small particle having punched the electrode layers and caused a short Notification sound does not operate Check the volume level False notifications without reason e Sensitivity maybe set too high Some other things like sudden big airpressure change may cause notifications See 4 for adjusting sensitivity Please never hesitate to contact manufacturer for any problems with use All feedback is highly appreciated 14 CLEANING The floor sensor can be cleaned with water and when necessary neutral general purpose or mild antiseptic detergents Always dry the sensor after cleaning Use a moist cloth for cleaning the control unit Clean also the bottom of the sensor and the floor where it is being installed to avoid small particles punch the sensor and cause a short THE CONTROL UNIT MUST NOT GET WET DO NOT CLEAN THE AC ADAPTER OR THE CONTROL UNIT WHEN IT IS CONNECTED TO THE MAINS OUTLET ALWAYS DRY IT WELL AFTER CLEANING 15 IMPORTANT SAFETY PRECAUTIONS TO AVOID POSSIBLE INJURY OR DEATH READ INSTRUCTIONS PRIOR TO USE ALWAYS TEST THE SYSTEM PER INSTRUCTIONS PRIOR TO USE THIS PRODUCT MAY NOT BE SUITABLE FOR ALL PERSONS THIS PRODUCT SHOULD NOT BE A SUBSTITUTE FOR MAINTAINING THE ROUTINE VISUAL MONITORING PROTOCOL BY CAREGIVER MUST NOT BE USED IN SITUATIONS WHERE A DELAY IN THE ARRIVAL OF APPROPRIATE CARE COULD
9. e guarantee service if these documents are not presented or if they are incomplete or illegible This Guarantee will not apply if the model name or serial number on the product has been altered deleted removed or made illegible This Guarantee does not cover transport costs and risks associated with transport of your product to and from Emfit This Guarantee does not cover a periodic maintenance and repair or parts replacement due to wear and tear Notice Emfit bed sensor wears and tears significantly faster when installed on soft base like spring mattress b consumables components that are expected to require periodic replacement during the lifetime of a product such as non rechargeable batteries C damage or defects caused by use operation or treatment of the product inconsistent with normal use d damage or changes to the product as a result of i misuse including treatment resulting in physical cosmetic or surface damage or changes to the product failure to install or use the product for its normal purpose or in accordance with Emfit s instructions on installation or use failure to maintain the product in accordance with Emfit s instructions on proper maintenance installation or use of the product in a manner inconsistent with the technical or safety laws or standards in the country where it is installed or used ii the condition of or defects in systems with which the product is used or incorporated except other Emfit
10. e limited as far as permitted by applicable law to the duration of this Guarantee EMFIT S ONLY OBLIGATION UNDER THIS GUARANTEE IS TO REPAIR OR REPLACE PRODUCTS SUBJECT TO THESE GUARANTEE TERMS AND CONDITIONS EMFIT IS NOT LIABLE FOR ANY LOSS OR DAMAGE RELATING TO PRODUCTS SERVICE THIS GUARANTEE OR OTHERWISE INCLUDING ECONOMIC OR INTANGIBLE LOSSES THE PRICE PAID FOR THE PRODUCT LOSS OF PROFITS REVENUE DATA ENJOYMENT OR USE OF THE PRODUCT OR ANY ASSOCIATED PRODUCTS INDIRECT INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGE THIS APPLIES WHETHER THAT LOSS OR DAMAGE RELATES TO IMPAIRED OR NON OPERATION OF THE PRODUCT OR ASSOCIATED PRODUCTS THROUGH DEFECTS OR UNAVAILABILITY WHILE WITH EMFIT WHICH CAUSED DOWNTIME LOSS OF USER TIME OR BUSINESS INTERRUPTION INACCURACY OF OUTPUT FROM THE PRODUCT OR ASSOCIATED PRODUCTS THIS APPLIES TO LOSS AND DAMAGES UNDER ANY LEGAL THEORY INCLUDING NEGLIGENCE AND OTHER TORTS BREACH OF CONTRACT EXPRESS OR IMPLIED WARRANTY AND STRICT LIABILITY EVEN WHERE EMFIT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Where applicable law prohibits or limits these liability exclusions Emfit excludes or limits its liability only to the maximum extent permitted by applicable law For example some countries prohibit the exclusion or limitation of damages resulting from negligence gross negligence wilful misconduct deceit and similar acts Emfit s liability under this guarantee will in no case exceed the price paid
11. end of the product s use life please dispose of it at appropriate collection points provided in your country For disposal or recycling information please contact your local authorities or the Electronic Industries Alliance EIA www eiae org 16 MATERIALS DISPOSAL X 17 DECLARATION OF CONFORMITY EU Emfit SafeFloor device model D 1050 2G and floor sensor model L 6090SL or L 60150 complies with the essential requirements of EMC directive 2004 108 EC and CE mark directive 93 68 EEC and carries the CE marking accordingly 18 U S FCC STATEMENT The United States Federal Communications Commission has specified that the following notice to be brought to attention of users of this product This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR THE COMPLIANCE COUL
12. for the product but if applicable law permits only higher liability limitations the higher limitations apply YOUR LEGAL RIGHTS RESERVED Consumers have legal statutory rights under applicable national laws relating to the sale of consumer products This guarantee does not affect statutory rights you may have nor those rights that cannot be excluded or limited nor rights against the person from whom you purchased the product You may assert any rights you have at your sole discretion 10 21 TECHNICAL SPECIFICATIONS Control Unit Model D 1050 2G Operating voltage 5V DC Input output connectors Power AUX and Sensor Dry contact ouputs Max 100 mA 60 V DC 25 V DC Switches and controls On Off Reset switch 8 DIP switches for program settings 1 pcs 10 position rotary switch for sensitivity adjustment Light indicators 3 LEDs Notification delays No delay or 6 sec Mounting On the wall with included bracket or on the table Dimensions mm 96 x 127 x 34 mm Weight 110g Color White Enclosure protection IP20 Case Plastic Floor Sensor Model L 6090SL Type Floor sensor Placing On the floor Portability Yes Dimension mm L x W 610 x 930 mm Thickness 2 5 mm Weight 1 kg Color Grey Surface material PVC Cable length 3m Environment conditions Operating temperature 10 C TO 40 C Storage and transportation temperature 30 C TO 50 C Humidity 20 75 Relative humidity 22 MANUFACTURER
13. ie eE Rr Rn E d tote dein UU 13 TROUBLESHOOTIN Gis eres ze ke eese esee ex Pete x kex Fry EXER Fee x aeu ves eese ess ex eue exe EX FX Rex x Eae XR tend votes ee suec vr ge ede er PY 14 CLEANING c erxse eres eenn tyes rav pin E RERER FERE FREE KEEREEE FER FERE EXE kr ev Ee S UYe X PUE PE VM KEREN EREREXEX TE TENANT ENT rede EXE Ve EE vex e vr PEU eE FEE E EXE CHER ERIS 15 IMPORTANT SAFETY PRECAUTIGONS 5 eere e vae ever a A reve Vr s yet Evra aree Vales erras eee ve vaa ee pe ev Vk Vv EY Ee Eo Yo V go 16 MATERIALS DISPOSAL a ves rave vvv aerae rwr een reor vn ea va ve LEYS VE VER S EVE Y SY V EY va NNA ava rase ba we ena o s ar EV VENER Var VE K ENE uaa 1 7 DEGLARATION OF CONFORM EU en rre rv rer Carter e e a tn CELE au ee e rrr Rr c rrr vr err Rat eara ala a alga BE EDAM erra ERE ne MP EMu MM He 19 CANADA 7 EMC COMPATIBILITY STATEMENT arnan rre trinken e erm ne tesi eme eI RE nag KG Ra Re UL BU TRA KR AUR RU E KE SS Sie e eet 20 EMFIT LIMITED WARRANTY STATEMENT 5 seen irt tii hie mieu E vive aevo neve e CHE FENK E eX Ex E REC CExF eX REO CE En a MES 21 TECHNICAL SPECIFIGATIONS 5 octsseeruseesseokvsesw eceesvneeoersieerxeewkzepaezencueucze neseuvesveF esr pecu rev gree ed oret roe ci pr eeea sever vie enin eii ye es 22 MANUFACTURER S AND ITS U S SUBSIDIARY S CONTACT INFORMATION eeeeneneee nemen menn nenne nares re nennen DANGER NOTES THE FOLLOWING NOTES ARE PROVIDED ON THE ONE HAND FOR YOUR PERSO
14. ing into use 5 INSTALLING THE FLOOR SENSOR 1 Put the included anti slip mat 2 Put the sensor on top of the i 3 If you are installing the sensor to first beside the bed so that the anti slip mat Take the wire to an out going door the top mat should other long edge goes slightly below the monitor X2 input be taped to the floor so that sand and the bed small stones do not get under the mat Those will soon punch the sensor electrodes and then it does not work anymore The tape should also prevent any water like melting snow in winter conditions to get below mat and causing sensor to de laminate 6 CONNECTORS AND WIRING Connectors are marked with X1 X2 and X3 These are X1 Power supply connector Use only GlobTek Inc power supply model no GTM41060 1505 and P N WR9QA3000LCP N MNK available as original accessory from Emfit X2 Aux connector for connecting the device to some other system cable not included for transferring the notification via a dry contact optocoupler DRY CONTACT OUTPUT OF THE X2 AUX CONNECTOR CAN ONLY BE CONNECTED TO A SYSTEM SAFETY VOLTAGE INPUT WITH MAX VOLTAGE BELOW 25V AC 60V DC WHERE BOTH POLES HAVE BEEN SEPARATED FROM THE ELECTRICAL NETWORK SO CALLED FLOATING APPLIED PART MAX LOAD CURRENT 100 mA X3 Sensor connector use only Emfit floor sensor model L 6090SL or L 60150 Connect the sensor optional AC adapter and possible connection wire to other system as fol
15. lows Connect the sensor wire plug to If you need to connect the dry Connect the optional AC adapter the X3 marked connector contact output to another system cord to the X1 marked connector plug the suitable connection wire to the X2 marked connector X2 AUX Connector Pin Order From left to right Pin 1 Common return Pin 2 Normally open NO send Pin 3 Normally Closed NC send Pin 4 Low battery warning send NO Pin 5 Not in use do not connect Pin 6 Not in use do not connect Pin 7 Not in use do not connect Pin 8 Not in use do not connect X2 DRY CONTACT OUTPUT OF THE X2 AUX CONNECTOR CAN ONLY BE CONNECTED TO A SYSTEM SAFETY VOLTAGE INPUT WITH MAX VOLTAGE BELOW 25V AC 60V DC WHERE BOTH POLES HAVE BEEN SEPARATED FROM THE ELECTRICAL NETWORK SO CALLED FLOATING APPLIED PART MAX LOAD CURRENT IS 100 mA 7 INSTALLING THE WALL MOUNT AND DEVICE INTO IT Attach the wall mount with the Slide the device into the mount Press the device downwards so included two anchors and screws you hear a click sound 8 INSTALLING BATTERIES AND BATTERY CONSUMPTION Product operates with 2 pcs AA size 1 5 V alkaline batteries Install and remove the batteries as follows aL c FA sm Open the cover by lifting from Install 2 pcs good quality AA size When removing old batteries one side 1 5 V alkaline batteries according they are easiest to remove by the polarity drawing
16. nstalled below flooring The sensor produces signals from even the slightest movement on the sensor 2 PACKAGE CONTENTS Control unit Floor sensor Wall mounting clip 2 screws 2 locking anchors This user s manual Optionally power supply 3 BEFORE USE SELECT THE RIGHT DIP SWITCH SSETTINGS Inside the device there is a so called DIP switch with 8 small switches These are used for various program settings See the following table and set up the switches for your preferred way To open the device cover see the picture on right Open the cover by lifting from one side Table of DIP Switch Settings chapter Switch OFF down ON up 1 Normal bed side operation no notification delay Door use 6 seconds delay to allow caregivers time to go and press SW1 switch for by passing notification 2 Manual reset Automatic reset NOTE Notification sound stops automatically after 30 seconds Ready to make new notification after 1 minute 3 Not in use leave OFF Not in use leave OFF 4 Not in use leave OFF Not in use leave OFF 5 Dry contact output is pulse mode about 1 sec Dry contact output is constant type Use only when pulse necessary by other system to be connected with Do not use with batteries but with optional power supply 6 Power switch function at SW1 is enabled device Power switch function at SW1 disabled device is can be shut down and turned on by
17. on When the automatic reset function DIP 2 is enabled ie ON the notification sound stops automatically after 30 seconds Device is ready to make new notification after 1 minute both by dry contact output and sound Therefore in automatic reset mode it is not necessary to press the SW1 for resetting the device As On Off Switch When the ON OFF switch function is enabled DIP switch 6 at OFF the SW1 switch functions also as ON OFF switch To turn the device ON or OFF just press the switch SW1 for about 3 seconds 12 TESTING AND INSPECTIONS Daily Inspection Test that the system gives the notification when you put your feet gently on the sensor as if person is leaving the bed and putting the feet slowly down on the floor 13 TROUBLESHOOTING ALWAYS CHECK FIRST THAT INSTALLATION IS CORRECT AND TEST THE DEVICE PROPERLY AFTER EVERY ADJUSTMENT Notification is not working or not getting forward via other system the device is connected to e Check that the connection cable is connected correct way and it is in good condition Often the wire both ends use same connector but wiring order is not the same Make sure it is connected the right way e Check that the device is switched ON It is ON if the blue light is blinking slowly If it is not blinking press the SW1 switch for 3 seconds If device does not turn on change the batteries or if you use AC adapter check it is connected and it s blue light is on e Ifred light is
18. pressing SW1 always on for about 3 seconds 7 Notification sound volume setting see next Notification sound volume setting see next chapter chapter 8 Notification sound volume setting see next Notification sound volume setting see next chapter Setting the Notification Sound Volume The notification sound is useful only when caregiver is in close proximity to the control unit The volume can be adjusted at 4 levels no sound quiet loud and very loud Volume level Switch 7 Switch 8 Very Loud OFF down OFF down Loud ON up OFF down Quiet OFF down ON up No sound mute ON up ON up In the automatic reset mode DIP switch 2 at ON the also by pressing the SW1 notification sound stops automatically after 30 seconds The sound stops ALWAYS REMOVE BATTERIES AND UNPLUG THE AC ADAPTER IF IN USE BEFORE MAKING CHANGES TO THE DIP SWITCH POSITIONS OTHEWISE THE NEW SETTINGS WILL NOT TAKE EFFECT 4 SETTING THE SENSITIVITY Sensitivity can be adjusted with 10 position rotary switch inside Factory default setting is the pointer pointing to 3 In case device does not notice light step on sensor adjust sensitivity higher by turning the pointer clock wise one position per time If the device notices unnecessary light movements on sensor and causes false notifications lower sensitivity by turning the screw counter clockwise one position per time Always test after every change before tak
19. s on the lifting from ends circuit board Estimated battery life is 6 months when using high quality alkaline batteries with 2800 mAh capacity 2pcs Estimation is based on measured battery consumption in various conditions and then a calculation where device is on 50 of time and shut down 50 of time WHEN THE BATTERIES ARE GETTING LOW THE RED LED BEGINS TO FLASH SLOWLY A BEEP SOUND WILL BE HEARD AFTER EVERY 1 5 HOURS AND THE DRY CONTACT OUTPUT GIVES LOW BATTERY NOTIFICATION AFTER EVERY 3 HOURS 9 ABOUT THE OPTIONAL 5V AC ADAPTER For preparing the optional power supply in use do the following Remove the plastic cover Pick up suitable adapter from the Install the adapter and make included 4 pcs sure it stays in its place THE EMFIT SAFEFLOOR BED AND DOOR EXIT MONITOR IS DESIGNED AND TESTED TO BE USED ONLY WITH GLOBTEK INC POWER SUPPLY MODEL NO GTM41060 1505 AND P N WR9QA3000LCP N MNK ANY OTHER TYPE OF AC ADAPTER MAY AFFECT THE PRODUCT S SAFETY The power supply is equipped with a blue indicator light when the light is on the power supply is in use If the light is off and the power supply is connected to the mains outlet the power supply is probably damaged and should be replaced POWER SUPPLY IN CASE OF NO MAINS POWER NOTE THAT ALL BATTERIES DRAIN EMPTY UPON TIME THEREFORE REPLACE BACK UP BATTERIES LATEST EVERY SECOND YEAR LOW BATTERY WARNING DOES NOT OPERATE WHEN AC ADAPTER IS CONNECTED TO TEST BATTERIES SWITCH THE
20. s products designed to be used with the product iii use of the product with accessories peripheral equipment and other products of a type condition and standard other than prescribed by Emfit iv repair or attempted repair by persons who are not Emfit employees v adjustments or adaptations without Emfit s prior written consent including upgrading the product beyond specifications or features described in the instruction manual or modifications to the product to conform it to national or local technical or safety standards in countries other than those for which the product was specifically designed and manufactured vi neglect vii accidents fire liquids chemicals other substances flooding vibrations excessive heat improper ventilation power surges excess or incorrect supply or input voltage radiation electrostatic discharges including lighting other external forces and impacts This guarantee covers only hardware components of the product EXCLUSIONS AND LIMITATIONS EXCEPT AS STATED ABOVE EMFIT MAKES NO WARRANTIES EXPRESS IMPLIED STATUTORY OR OTHERWISE REGARDING PRODUCT OR ACCOMPANYING OR CONSTITUENT SOFTWARE QUALITY PERFORMANCE ACCURACY RELIABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE If this exclusion is not permitted or fully permitted by applicable law Emfit excludes or limits its warranties only to the maximum extent permitted by applicable law Any warranty that cannot be fully excluded will b
21. unit The control unit has an audible notification sound and a dry contact output for connecting it to the other parts of the system Control Unit The control unit D 1050 2G gives notification after it has noticed step on a sensor For door exit use a 6 second delay can be set for caregivers to press by pass switch and pass the door without activating a notification L P o The control unit processes a low voltage from about 1 mV up to about 1 V high t d impedance signal from the dynamic quasi piezoelectric type i e self biased flexible film like sensor The control unit operates with 2 pcs AA size 1 5 V alkaline batteries An optional Y AC adapter is available 5 VDC AC ADAPTERS OTHER THAN ORIGINAL D ACCESSORIES FROM EMFIT MUST NOT BE USED The control unit has input connectors for the AC adapter and sensor There is also a connector for connecting the device to other systems for transferring the notification via dry contact optocoupler A reset switch for turning off the notification sound is to the right of the sensor input marked as SW1 Inside the device there is a place for 2 pcs AA size 1 5 V alkaline batteries and mini switches DIP and rotary for program settings Floor Sensor The Emfit floor sensor is a quasi piezoelectric dynamic sensor that has no embedded wires or switches This specially formulated plastic sheet sensor model L 6090SL is placed on top of the flooring Sensor model L 60150 is intended to be i

Download Pdf Manuals