1. Ll rit lndoor Temperature Outdoor Temperature T Pressure Wind Speed m s Display Format Time Axis Ful Date mmddyy 24H 12 Hours Outdoor Temperature Pressure Velocity Rainfall Temperature Absolute wind Hour Alarm Enable Time wind Direct Indoor Humidity Low Indoor Humidity High Outdoor Humidity Low Outdoor Humidity High Indoor Temperature Low Indoor Temperature High Outdoor Temperature Low Outdoor Temperature High Windchill Low Windchill High Dewpoint Low Dewpoint High Absolute Pressure Low Absolute Pressure High Relative Pressure Low Relative Pressure High Wind Speed High Gust Speed High Hour Rainfall High Dav Rainfall High Pressure Relative Absolute Hpa This section is used to set up PC software display base station units as well as able or disable the corresponding alarm function Once you made your choice press Save to make the setting effective display and setup system alarm value S is pe FI i ce Lid na Lo na c c E a HI i This section is used to set the desired time high or low alarm value for the base unit Once you made your choice choose Save to make the setting effective If you don t want to make any change just press Cancel and exit without change display min and max
2. display listed history data 9 _ History Data E 2l xl Search Condition 2007 07 10 11 53 39 2007 07 10 12 00 1 E5 32 8 55 3b 2007 07 10 12 01 Bo 32 8 55 af 2007 07 10 12 02 1 Ja 33 9 55 38 2007 07 10 12 03 1 d3 33 5 55 3d 2007 07 10 12 04 1 3 35 55 40 2007 07 10 12 05 1 98 34 1 E5 41 2007 07 10 12 05 1 99 34 1 E5 42 2007 07 10 12 07 1 98 34 1 E5 43 2007 07 10 12 08 1 98 34 1 E5 44 2007 07 10 12 03 1 34 0 Bo 45 2007 07 10 12 10 1 BE 34 3 65 46 2007 07 10 12 11 1 90 Sad 65 4 2007 07 10 12 12 1 34 0 65 48 2007 07 10 12 13 1 92 33 4 65 43 2007 07 10 12 14 1 93 33 6 Eq 50 2007 07 10 12 14 1 94 33 0 51 2007 07 10 12 15 1 74 32 3 Eq 52 2007 07 10 12 16 1 r 33 0 33 2007 07 10 12 17 1 3 54 2007 07 10 12 18 1 33 1 55 2007 07 10 12 19 1 65 33 1 56 2007 07 10 12 20 1 65 33 1 of 2007 07 10 12 21 1 E4 33 1 4 58 2007 07 10 12 22 1 Bd 33 1 53 59 2007 07 10 12 23 1 53 33 0 53 Bl 2007 07 10 12 24 1 53 33 0 53 51 2007 07 10 12 25 1 53 33 0 53 Refresh Clear Data Clear Memory Graph Export Cancel This section is used to display recorded history data in a spread sheet If you wanted to see all history data in a desired time period choose the time duration and press Search to reload the history data With the Export button you can export the selected history data into text format file for other application purpose When memory on base st
3. button and H button will be flashing Touch the button or H button to Shift the display unit between hPa inHg and mmHg 3 Touch the PRESSURE section the third time to set the Relative Pressure value The and H button will be flashing rel icon will light up Touch button or H button to change the value hold the button or H button for 3s to change the number in great step 4 Touch the PRESSURE section the forth time to set the pressure high alarm function the and H button will be flashing AL icon will light up Touch button or H button to change the value hold button or H button for 3s to change the number in great step Touch the button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 5 Touch the PRESSURE section the fifth time to set the pressure low alarm function the h and button will be flashing LO AL icon will light up Touch the button or button to change the value hold button or H button for 3s to change the number in great step Touch the button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 6 Touch the PRESSURE sections the sixth time to display maximum pressure record to display maximum pressure the recorded maximum value will be flashing MAX icon will light up as well Hold the maximum value for 3s the maximum val
4. Relative Air Pressure see further down any further basic settings Changes however can be easily made For basic settings the following menu is started by touching the Touch Screen in the desired display area The basic settings can now be performed in the following successive order Note setting procedure can be exited at any time by touching any other function area except or ON OFF acho OUT TEMP jus SL Activate the indoor temperature related setting by 1 Touch the INDOOR TEMPERATURE section button and H button will be flashing Touch the button or H button to Shift the display unit between C and F 2 Touch the INDOOR TEMPERATURE section again to set the indoor temperature high alarm function the and H button will be flashing HI AL icon will light up Touch thel button or H button to change the value hold button or button for 3s to change the number great step Touch the button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 3 Touch the INDOOR TEMPERATURE section the third time to set the indoor temperature low alarm function the and H button will be flashing LO AL icon will light up Touch thel button or H button to change the value hold the button or H button for 3s to change the number in great step Touch the button to choose the alarm on or off if alarm is enabled the spea
5. cable supplied and connect the Base Station to the PC From now on you can start to track current and history weather information at your finger tips 2 0 System Requirements To install the EasyWeather software onto your PC the minimum requirements are as follows Operating System Windows NT4 Service Pack gt 6a Windows 2000 Windows XP Windows Vista Windows 7 Internet Explorer 6 0 or above Processor Pentium Ill 500 MHz or above Memory at least 128MB 256MB recommended CD ROM Drive Base Station and PC must be connected by USB cable 3 0 Installation of the EasyWeather Software Firstly the Base Station and the Outdoor Sensors should be connected and checked for correct function see Operation Manual for setting up the Weather Station After successful checking install the EasyWeather software as follows Switch on your PC and insert the CD ROM into the CD ROM Drive Double click Setup exe Select the installation process language option and click next click next and select the destination folder change directory when needed click next and the software will be installed automatically press ok to finish the installation process From Start All Programs EasyWeahter path and double click the EasyWeather icon to start application QUOSQUE TO rS Note The graphic function needs the software to be installed under the administrator account If it is installed under limited user accounts the gr
6. north if you reside in the southern hemisphere Solar panel facing south if you reside in the northern hemisphere Important Notes On the edge of wind direction sensor there are four alphabet letter of N E S and W representing for the direction of North East South and West Wind direction sensor has to be adjusted so that the directions on the sensor are matching with your real location Permanent wind direction error will be introduced when the wind direction sensor is not positioned correctly during installation System Start Insert two pieces of AA size lithium rechargeable batteries into the transmitter the LED located in the middle front case of transmitter will be turned on for 4 seconds then it will be off and start to work normally The transmitter will make a data transmission When there is a data transmission happened the LED will be on for 20ms After inserting the batteries into the Weather Station all LCD segments will be turned on for a few seconds all possible display segments are turned on for checking After this the weather station will make initial measurement and start to register the transmitter the radio reception icon will be turned on Before there is outdoor data received it is not allowed to touch the LCD otherwise the outdoor sensor learning mode will be terminated right after the touch of LCD When outdoor transmitter has been registered the Touch Screen Weather Station will automatically swi
7. pressure in the United States HECTOPASCALS hPa Hectopascals are the common units of measurement for air pressure in the International System SI of measurement The hectopascal holds the same value Important Note Before inserting batteries please carefully read the operation manual The touch screen weather station includes a base station receiver a solar powered transmitter unit one wind direction sensor one wind speed sensor one rain gauge USB cable and a PC software package on CD ROM The Base Station is equipped with a Touch Screen LCD Monitor and allows the display of a large variety of time and weather data Left Top LCD IN OUT temperature and humidity Right Top LCD Wind and Rain measurement Left Middle LCD Weather Forecast Tendency Right Middle LCD Air Pressure and Air Pressure History Bottom Line LCD Time and Date Memory Data Usage Note The presence of the Alarm On icon in the section means that the particular alarm has been enabled TENDENCY DIT Q An added feature of the Weather Station is the readout of all measured and displayed time and weather data on a PC Important Operation Notes All actions and functions of the weather station are started on the touch screen by slightly touching not pressing the related areas touch the flashing H or H to make the corresponding selection or increase the value Every time a programming step is activated by touch
8. products are protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties e You may not copy the printed materials accompanying the products Em
9. recorded value 18 Indoor Humidity aximum Time TE 2007 01 02 11 14 Minimum Time X 2007 01 02 15 04 Indoor Temperature amu Time 34 0 05 2007 01 02 16 12 Minimum Time 28 9 9 EJ 9 05 24 13 14 windchill 45 87 Minimum 27 4 pe Absolute Pressure Time 2007 01 01 12 02 Time 2007 01 02 15 40 Masimum Time 29 59 inHg 2007 01 02 04 51 Minimum Time 23 34 inHg wird asimurm a km h Fain M asimum Hour o o mm week 00 mm 207 9 05 29 15 03 Time 2007 01 02 13 18 Time 2007 51 03 11 14 Time 2007 01 03 11 14 Time 2007 01 03 11 14 Total 0 0 mm This section is used to display the recorded min and max value recorded with time stamp Min Max Outdoor Humidity Time fo 2007 01 03 23 49 Minimum Time E EE 2007 01 02 08 20 Outdoor Temperature asinum Time 45 8 2007 01 01 12 02 Minimum Time 2007 01 D2 18 40 Dewpoint asimum BE Minimum fi ga Relative Pressure Time 2007 01 An 12 02 Time 2007 01 3 15 27 Masimum Time 29 56 inHg 2007 01 03 12 25 Minimum Time 2847 inHg Gust asimum 24 6 km h 2007 01 I3 12 91 Time 2007 01 I3 12 05 Time 2007 01 03 11 14 Time 2007 01 I3 11 14 reset can only be done through key operation on the base station
10. 07 05 00 00 00 2007 07 05 06 00 00 Sample Time Series Humidity Type Line apr Refresh Export Cancel s Search 24 hours StartT ime 2007 07 04 11 26 16 EndTime 2007 07 05 11 26 16 m Search Weather Humidity 2007 07 04 12 00 00 2007 07 04 13 00 00 2007 07 04 14 00 00 2007 07 04 15 00 00 Sample Time Series Humidity Line EM Refresh Export Cancel Also you can see the graph in 3D mode by selecting the 3D check box Graph ni loxi Search p4hous v StatTime 2007 07 04 11 26 16 2 Endlime 2007 07 05 11 26 16 VWeather Humidity Indoor Humidity Outdoor Humidity Humidity unit 96 2007 07 04 12 00 00 2007 07 04 18 00 00 2007 07 05 00 00 00 2007 07 05 06 00 00 Sample Time Series Humidity Type Line 3bi Refresh Export You can change the Y axel by scrolling the mouse and down roller What to do if graph function is not working 7 This is the most encountered problem with this software To make the graph function working properly please check the following step 1 find the folder where the EasyWeahter exe file is located 2 Create a file name reg graph bat file with wordpad or notepad editor program type regsvr32 easyweather ocx and save the reg graph bat file 4 Double click reg graph bat file and it should register the gra
11. L icon will light up Touch the button or H button to change the value hold button H button for 3s to change the number in great step Touch the button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 4 Touch the rain section the fourth time to display current maximum rain fall record Touch the rain section for 3s will reset the maximum rain fall value to current value 5 Touch the rain section the fifth time to reset rain fall value to 0 by pressing the rain section for 3s then 1h 24h week month and total rain will be reset to 0 Weather forecast TENDENCY i Uh 1 Touch the WEATHER FORECAST section button and H button will be flashing Touch the button or H button to Shift the display between SUNNY PARTLY CLOUDY and CLOUDY RAINY icon 2 Touch the WEATHER FORECAST section again button and H button will be flashing Touch the button or H button to set the pressure threshold from 2 4hPa default 2hPa 3 Touch the WEATHER FORECAST section the third time button and H button will be flashing Touch the button or button to set the storm threshold from 3 9hPa default 4 hPa Pressure si lil Hilt d Ii 1 Touch the PRESSURE section button and H button will be flashing Touch the button or H button to Shift the display between Absolute pressure and Relative pressure 2 Touch the PRESSURE section again
12. N or OFF this function is only available for WWVB version while for DCF version this feature is not activated Note DST OFF indicates that the feature is off and the internal real time clock will not change times automatically DST ON indicates that the feature is on and the internal real time clock will change times according to the DST time schedule automatically Some locations Arizona and parts of Indiana do not follow Daylight Saving Time and should select DST OFF 5 Touch the TIME section the fifth time to set the hour the and H button will be flashing Touch button or H button to change the value 6 Touch the TIME section the sixth time to set the Minute the and H button will be flashing Touch H button to change the value Date ALARM DATE MEMORY 1 Touch the DATE section button and H button will be flashing Touch the button or H button to shift between alarm time date and week date 2 Touch the DATE section again button and H button will be flashing Touch the button or H button to Shift between DD MM format and MM DD format for the date 3 Touch the DATE section the third time button and H button will be flashing Touch the button or H button to set the year Hold the button or H button for 3s to change the number in great step 4 Touch the DATE section the fourth time button and button will be flashing Touch the button or but
13. TOUCH SCREEN WEATHER STATION WITH SOLAR TRANSMITTER Operation Manual About this manual Thank you and congratulations on selecting this professional weather station We are positive you will enjoy the benefits of accurate weather readings and the precise radio controlled time information that our instruments offer A solar powered weather station has the advantage of being able to provide energy for long periods of time This manual will guide you step by step through setting up your device Use this manual to become familiar with your professional weather station and save it for future reference Glossary of Common Terms LCD LCD is an acronym for Liquid Crystal Display This is a common type of display screen used in televisions computers watches and digital clocks BAROMETER amp BAROMETRIC PRESSURE A barometer is a device that measures the pressure of the air pushing on it this measurement is called the barometric pressure We don t actually feel the barometric pressure because the air pressure is pushing equally in every direction RELATIVE AIR PRESSURE Relative air pressure is the same as the barometric pressure The calculation of relative air pressure is a combination of the absolute air pressure and the altitude ABSOLUTE AIR PRESSURE Absolute air pressure is the actual air pressure on the barometer without regard to altitude INCHES OF MERCURY inHg Inches of Mercury are the common unit of measurement for air
14. aphic function of the software might not be working correctly To run easyweather in windows Please note that enduser should run the easyweather in windows as administrator 1 Click start icon 2 Find easyweather program and right click mouse 3 Click run as administrator us 4 0 Basic Settings of the EasyWeather Software After the EasyWeather exe program has been started the following main window will appear on the PC screen Mt Easy weather Radio Controlled Display System Help B m Rel Pressure Abs Pressure Min Hpa LO Min Hpa Lo Max Hpa Hpa Vind cm 0 1 2 3 4 5 8 7 8 g 10 11 12 gt Ba l e e Level N e AR gt 2 AS a d I a gt lel All the settings from the base unit is mirrored into the PC software so once you have done your setting on the base unit then you don t need to make any setting changes on the PC software However you can still easily make any setting changes you wanted from the PC and download the changes into the base station the setting change will be refreshed when next full minute arrives on the base station a When base unit is connected to PC the icon of will be displayed If no base station is connected then Will be displayed Function button B display and setup system configuration 16 Interval Minute Time one
15. arm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 2 Touch the INDOOR HUMIDITY section again to set the indoor humidity low alarm function the and H button will be flashing LO AL icon will light up Touch thel button or H button to change the value hold button or H button for 3s to change the number in great step Touch the button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 3 Touch the INDOOR HUMIDITY section the third time to display maximum indoor humidity record the recorded maximum value will be flashing MAX icon will light up as well Hold the maximum value for 3s the maximum value will be reset to current reading 4 Touch the INDOOR HUMIDITY section the fourth time to display minimum indoor humidity record the recorded minimum value will be flashing MIN icon will light up as well Hold the minimum value for 3s the minimum value will be reset to current reading Outdoor humidity Procedures and settings are similar to Indoor humidity Wind speed Activate the wind related setting by 1 Touch the WIND SPEED section button and button will be flashing Touch the button or button to Shift the display between Wind Average Speed and Gust Speed 2 Touch the WIND SPEED section again button and button will be flashing Touch the button or H button to se
16. ation is full press Clear Memory button to refresh the memory space on the base station remember to upload all data before pressing this button If you wanted to start a new weather history record press Clear Data button to clear up the data base all history weather data will be deleted if you would like to keep a back up history file before deleting all weather data you can make a copy of the EasyWeather dat file into another folder or just rename the EasyWeather dat file such as Jan 07 dat for future reference aa display history data in graph mode 20 __ 4 Search ordin 24hours v Statlime 2007 07 04 11 26 16 lt 1 EndTime 2007 07 05 ES 11 26 16 VWeather Humidity Indoor Humidity Outdoor Humidity Humidity unit 95 2007 07 04 12 00 00 2007 07 04 18 00 00 2007 07 05 00 00 00 2007 07 05 06 00 00 Sample Time Series Humdiy Line 3D 7 Refresh Export Cancel In this section you can see the history data plotted in graph format for easier observation If you want to see more details just use your mouse to select the area you wanted and the display will be automatically updated in more detailed scale 24heus StantTime 2007 07 04 E 11 26 16 lt 1 EndTime 2007 07 05 EE 11 26 16 wWeather Humidity Indoor Humidity Outdoor Humidity Humidity unit 95 2007 07 04 12 00 00 2007 07 04 13 00 00 2007
17. e is lower than 20 C make sure proper type of batteries to be used to assure that the device can get enough power to maintain its function properly 15 depot Please help in the preservation of the environment and return used batteries to an authorized All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged z TAs EasyWeather PC Software User Manual 1 0 General Information This Weather Station is a high quality easy to use weather monitoring system that reads displays and records the weather data from internal as well as external sensors Besides the internally measured values for indoor temperature indoor humidity and air pressure the outdoor sensor will take data for temperature and humidity wind and rainfall Operation of these units is by wireless transmission to the Base Station After installing the EasyWeather program on this CD ROM your PC can display all indoor data as well as the weather data from the Base Station received from the external sensors For operation simply use the USB
18. er icon will be turned on indicating the alarm function has been enabled 4 Touch the OUTDOOR TEMPERATURE section the fourth time to set the outdoor temperature low alarm function the and H button will be flashing LO AL icon will light up Touch button or button to change the value hold the button or button for 3s to change the number in great step Touch the button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 5 Touch the OUTDOOR TEMPERATURE section the fifth time to display maximum outdoor temperature record the recorded maximum value will be flashing MAX icon will light up Hold the flashing max value for 3s the maximum value will be reset to current reading 6 Touch the OUTDOOR TEMPERATURE section the sixth time to display minimum outdoor temperature record the recorded minimum value will be flashing MIN icon will light up as well Hold the minimum value for 3s the minimum value will be reset to current reading Indoor humidity IN TEMP HUMIDITY Bs i RH OUT TEMP Activate the indoor humidity related setting by 1 Touch the INDOOR HUMIDITY section again to set the indoor humidity high alarm function the and H button will be flashing AL icon will light up Touch thel button or H button to change the value hold button button for 3s to change the number in great step Touch the button to choose the al
19. ing a switching area on the Touch Screen a tone will sound and the back light is switched on for a few seconds as well If no areas are pressed for 30 seconds the LCD will automatically revert to the normal display mode automatic time out Getting Started Setup Sensors Sa mee lt a O __ gt WD 2 Anemometer wind direction sensor ee ee SSS SE ESS 3 Mounting the dual wind sensor holder 5 Mounting the rain sensor Thermo hygro sensor with solar panel Mounting the thermo hygro sensor Fix the whole set to a pole same as rain sensor with the two adjustable hoops The anemometer s cable is connected to the input on the wind direction sensor The wind direction sensor s cable is connected to the input marked Wind on the thermo hygro sensor The rain sensor s cable is connected to the input marked Rain on the solar panel The solar panel s cable is connected to the input marked Rain on the thermo hygro sensor The solar transmitter The solar transmitter makes use of solar energy to power the instruments they are connected to Note It use AA size alkaline batteries For the solar transmitters to function properly make sure the solar receptors on the transmitters are exposed to sunlight and the connectors of the connection cable are securely plugged in For best results direct solar panel as follows Solar panel facing
20. ker icon will be turned on indicating the alarm function has been enabled 4 Touch the INDOOR TEMPERATURE section the fourth time to display maximum indoor temperature record the maximum records will be flashing MAX icon will light up as well Hold the flashing max value for 3s the maximum value will be reset to current reading 5 Touch the INDOOR TEMPERATURE section the fifth time to display minimum indoor temperature record the minimum records will be flashing MIN icon will light up as well Hold the flashing min value for 3s the minimum value will be reset to current reading outdoor E CBE OUT TEMP uuo DL TENDENCY I ly HIT fait HH d Activate the outdoor temperature related setting by 1 Touch the OUTDOOR TEMPERATURE section button and button will be flashing Touch the button or H button to Shift the display between Outdoor Temperature Wind Chill and Dew Point 2 Touch the OUTDOOR TEMPERATURE section again button and H button will be flashing Touch the button H button to Shift the display unit between C and F 3 Touch the OUTDOOR TEMPERATURE section the third time to set the outdoor temperature high alarm function the and H button will be flashing HI AL icon will light up Touch button or H button to change the value hold the button or button for 3s to change the number great step Touch the button to choose the alarm on or off if alarm is enabled the speak
21. lect wind speed unit between km h mph m s knots bft 3 Touch the WIND SPEED section the third time to set the high alarm function the and H button will be flashing HI AL icon will light up Touch button or H button to change the value hold button or H button for 3s to change the number in great step Touch the button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 4 Touch the Wind SPEED section the fourth time to set wind direction alarm function the wind direction arrow will start to flashing Touch or to select desired alarm for wind direction press ON OFF to enable or disable the wind direction alarm 5 Touch the Wind SPEED section the fifth time to display maximum wind speed record the recorded maximum value will be flashing MAX icon will light up as well Hold the maximum value for 3s the maximum value will be reset to current reading Rain 5 SW SE 1B Activate the rain related setting by 1 Touch the rain section button and H button will be flashing Touch the button or H button to Shift the display between 1h 24h week month and total rain 2 Touch the rain section again button and H button will be flashing Touch the button or H button to select rain fall unit between mm inch 3 Touch the rain section the third time to set the high alarm function the and H button will be flashing HI A
22. llation software is very simple double click the setup exe file and follow the steps popped up Make sure you are running the program under the administrator accounts of your windows PC platform Otherwise the graphic function might not be working when graph display mode is needed to display all history data If you run the program for the first time the current weather display will be displayed and at the sub line of the window the program will show related information regarding the read of all history data into the PC Please note however when there is large amount of data is being uploaded it will take a few minutes time before the system can respond to your setup settings Otherwise it will display read weather data fail error message since the USB port is reading the data from the memory and the system is not able to respond any further job tasks xq EasyWeather Radio Controlled Display System Record Help B amp 1 2 Rel Pressure Abs Pressure Temperature Min C le lel l A gt Humidity e 5 e f A a 3 ES 5 gu 0 2007 07 04 12 00 00 2007 07 04 18 00 00 2007 07 05 00 00 00 2007 07 05 06 00 00 Sample Time Series Line EM Refresh Export Cancel When memory is full it will take about two minutes to upload all history data into PC and it takes another two minutes to process all history data for graphic display Furthe
23. phic driver again If successful then the following window will be displayed TREES ee T er PER HEEL IG Program Files EasylUeather regsur32 eazyueather ocx Heg5vr32 1 019 egisterS erver in easyweather ocs succeeded 2 Special Notes about time synchronization between and sub station The PC software obtained its own time scale through the time interval marker from the base station history data and the PC software automatically synchronizes the weather data with a time stamp calculated Thus the history data file can have different time when the PC time and base station time is not same In order to make the time scale correct remember to set the PC time and base station time same and further to this no weather data is allowed to be missed or over written If history weather memory on the base station is cleared by manual setting then the history weather data since last uploading is lost permanently Before memory is used up memory icon on LCD display showing 100 full remember to upload weather history data to PC periodically If there is a reset happened for the rain fall on the base station then there will be rain fall value discrepancy between PC and base station Legal Notes e We reserve the right to delete or change any image whether or not purposely uploaded onto the server by a user of the EasyWeather software products e he EasyWeather software
24. r detailed PC software user manual can be found from the help menu aiae opecifications Outdoor data Transmission distance in open field Frequency Temperature range Accuracy Resolution Measuring range rel humidity Accuracy Rain volume display Accuracy Resolution Wind speed Accuracy Measuring interval thermo hygro sensor Water proof level Indoor data Measuring interval pressure temperature Indoor temperature range Resolution Measuring range rel humidity Resolution Measuring range air pressure Accuracy Resolution Resolution Alarm duration Power consumption Base station Remote sensor Battery life 100m 300 feet 433MHz 40 65 40 to 149 1 C 0 1 10 99 5 0 9999mm show if outside range 10 0 3mm if rain volume 1000mm 1mm if rain volume 1000mm 0 160km h 0 100mph show if outside range 1m s wind speed 10m s 10 wind speed gt 10m s 48 sec IPX3 48 sec 0 C 50 C 32 122 show if outside range 0 1 C 10 99 1 300 1100hPa 8 85 32 5inHg 3hpa under 700 1100hPa 20 73inHg 31 89inHg 0 1hPa 0 01inHg 0 1hpa 0 01inHg 120 sec 3XAA Alkaline batteries not included 2xAA Alkaline Batteries included Minimum 12 months for base station Minimum 36 months for thermo hygro sensor Remark Be sure to use 1 5V rechargeable battery for solar transmitter Where outdoor temperatur
25. tch to the normal display mode from which all further settings can be performed by the user Note f the outdoor data lost or a battery change for the transmitter the base station will be resynchronize to the transmitter again within the next 3hours If you want to shorten the receiving data time you can press the reset button on the solar power cabinet to re send the signal You have to re install the batteries of the base station as well to re learn the signal Please wait 10 seconds before re insert the battery again to make a proper reset for both transmitter and receiver Positioning Once you have verified that all of the components of the weather station are working they can be positioned in their permanent places Before permanently mounting make sure that all components work properly together at their chosen mounting or standing locations Note Commonly the radio communication between receiver and transmitter in the open field can reach a distance of up to 330 feet providing that there are no interfering obstacles such as buildings trees vehicles high voltage lines etc Radio interferences such as PC screens radios or TV sets can in bad cases entirely cut off radio communication Please take this into consideration when choosing standing or mounting locations Setting Up Note Because of the default settings already determined by the manufacturer it may not be necessary for the majority of users to perform except the
26. the memory full icon for 3 seconds will clear the memory PC Connection As an important feature in addition to the display on the Touch Screen the Weather Station allows the read out of all measured and displayed time and weather data in form of complete history data sets on a PC Data Storage SN S For a comprehensive weather history the Base Station allows the internal storage of up to 4080 complete sets of weather data with time and date The base station will loose all weather data if an interruption of power supply In case the memory capacity of the Weather Station is exhausted the oldest data sets stored will be overwritten by the new ones entered Data Recall Certain weather data or setting values can only be read out processed and displayed by means of a PC Also the settings of the storing intervals from 5 minutes to 240 minutes for the storage of data sets can only be performed by means of a PC Connections and Software The wiring between Weather Station and PC takes place by means of an included USB cable The EasyWeather software package also included in the shipping contents must be installed on the PC This software allows the display of all present weather data with graphic symbols It also allows the display storage and printing of history data sets whose volume exceeding the maximum 4080 data sets of the Weather Station is only limited by the capacity of the PC s main memory PC software installation The insta
27. ton to set the month Hold button or button for 3s to change the number in great step 5 the DATE section the fifth time button and button will be flashing Touch the button or button to set the day Hold thel button or H button for 3s to change the number in great step 6 Touch the DATE section the sixth time button and H button will be flashing Touch the button or H button to set the alarm hour Hold the button or H button for 3s to change the number in great step 7 Touch the DATE section the seventh time button and H button will be flashing Touch the button Or button to set alarm minute Hold the button or button for 3s to change the number in great step Touch ON OFF to enable or disable time alarm function Memory 1 Touch Memory section to activate history data toggle display button and button will be flashing Press to toggle forward to see earlier weather history data together time stamp press to see later history weather data When history data displayed the corresponding time will be displayed at the time section area History data saving interval can only be changed using the PC software that comes with this product the default history data saving time interval is preset to 30 minutes prior to shipment 2 Touch Memory section again will trigger the memory clear procedure the word of CLEAR will be flashing the full memory usage icon will be flashing Press and hold
28. ue will be reset to current reading 7 Touch the PRESSURE section the seventh time to display minimum pressure record to display minimum pressure record the recorded minimum value will be flashing MIN icon will light up as well Hold the minimum value for 3s the minimum value will be reset to current reading Note when absolute pressure is selected step 3 will be skipped since absolute pressure is selected for display Pressure bar graph Touch the PRESSURE BAR GRAPH section and then press or to toggle the bar graph time scale between 12hrs or 24 hrs for pressure history Time Q ILFLID 30 1 Touch the TIME section button and H button will be flashing Touch the button or H button to adjust the contrast level from 0 to 8 default 5 2 Touch the TIME section again button and H button will be flashing Touch the button or H button to set the time zone Note At Europe 0 for GMT 1 time zone 1 for GMT 2 time zone 1 for GMT time zone At America 4 for Atlantic time zone 5 for Eastern Time zone 6 for Central Time Zone 7 for Mountain Time zone 8 for Pacific time zone 9 for Alaska time zone 10 for Hawaii time zone 3 Touch the TIME section the third time button and button will be flashing Touch the button or button to Shift the 12 24 hours format 10 4 Touch the TIME section the fourth time button and button will be flashing Touch the button or button to set the DST O