RaySafe X2 View - Fluke Biomedical

image

Contents

1. cs ucssecnswsyssceasdocavecssucuseseinsauecudesuteanderedesisedndedsi 15 Update the RaySafe AZ system ccic sic snte case case cusedsctcnsacasnsncesackdusscudende deck ansadens 16 PUN Tvs E T psa E EE N EE E ant pede T A enero 17 TrOUDESAO OUN irosen nirea E E DAAE AEA ADN 1 SION U eE A E E EEA 17 Technical SUDDO E eerenninnn aneen kanni EE EEES ENESE EE EEEE RA ERE Er REER BEENS 18 RaySafe X2 View User Manual Program overview PROGRAM OVERVIEW RaySafe X2 View is suitable for e viewing and analyzing measurement data and waveforms e storing measurements transferring data to Excel or other software e updating the base unit software E RaySafe X2 View 1 1 C temp Measurements x2v File Edit View Help RaySafe X2 Measurements Dose Time Half value layer Dose rate Pulses Total filtration Dose per pulse Pulse rate N ronne 69 2 kVp 169 2 uGy 501ms 405mmAIH 3 376 mGy s 1pulse 5 9 mm AI TF mGy puls pulses s 69 8 kVp 171 4 uGy 501ms 405mmAIH 3 420 mGy s 1pulse 5 9 mm Al TF mGy puls pulses s 69 8 kVp 173 0 uGy 501ms 4 07mmAlH 3 450 mGy s Ipulse 6 0 mm Al TF mGy puls pulses s 70 0 kVp 175 2 uGy 501ms 408mmAIH 3 495 mGy s 1pulse 61mm AITF mGy puls Fas Dose unit 69 5 kVp 176 9 uGy 501ms 407mmAlH 3 528 mGy s 1pulse 6 0 mm AI TF mGy puls pulses s ma delay 69 7 kVp 178 8 uGy 50 2ms 4 06mmAlH 3 563 mGy s 1pulse 5 9 mm AITF mGy puls pulses s 05s
2. 69 5 kVp 180 9 uGy 501ms 4 06mmAIH 3 608 mGy s 1pulse 6 0 mm AI TF mGy puls pulses s ignore prepulses 3 69 6 kVp 182 7 pGy 50 2 ms 405mmAlH 3 641mGy s 1pulse 5 9 mm Al TF mGy puls pulses s leas 69 6 kVp 184 8 uGy 50 2 ms 406mmAIH 3 681 mGy s 1pulse 5 9 mm AI TF mGy puls pulses s 69 2 kVp 187 0 pGy 50 3 ms 404mmAlH 3 722 mGy s ipulse 5 8mm Al TF mGy puls pulses s 188 6 Gy 50 2 ms 405mmAlH 3 758 mGy s 1pulse 5 9 mm Al TF mGy puls pulses s J Waveforms Time ms 7 Duration 15 6 k z T Start time 17 3 x Stop time 32 9 L3 gt 2 2 Tube voltage kV g Min 67 02 lms 3 g Automatically export to Excel 4 Lo W Tube voltage kV 68 5 Information About X2 BaseUnit 4010 4 X2 RIF Sensor 114 Figure 1 The main window 1 RaySafe X2 status shows connections to other parts of the RaySafe X2 system Excel area manages export of measurements to Excel see Export to Excel 11 Arrows for hiding showing the panels 2 3 4 Measurements see View measurements 8 5 Waveforms see View waveforms 9 for the selected measurement 6 Measurement information calibration dates for the sensors settings used during the selected measurement and a field for taking notes RaySafe X2 View User Manual Import measurements IMPORT MEASUREMENTS IMPORT AS YOU MEA
3. internet The X2 Online field will show a notification icon if there are any updates available for you x2 Online a Figure 16 Update notification to the right Click on the icon to go to the update window below Click Update to download and install the update or Cancel to postpone the update Available Updates You have 1 available update s WD x2 Base unit 2 20 5927 Figure 17 Update window 16 RaySafe X2 View User Manual Hints HINTS TROUBLESHOOTING No instrument is shown in the RaySafe X2 status area even if a base unit is connected Disconnect and reconnect the base unit to the computer using the USB cable X2 Online does not appear in the RaySafe X2 status area Make sure that the computer running X2 View is connected to the internet SHORTCUTS KEYBOARD SHORTCUT ACTION Up arrow Show previous measurement Down arrow Show next measurement Ctril N Make a new file Ctrl O Open an existing file Ctrl S Save file Ctrl Shift S Save file with a new name Save As Alt C Change to Compact view Alt D Change to Default view F1 View Help F2 Open About window F4 Open Settings window F8 Open Import from base unit window Ctri A Mark all measurements Ctrl C Copy all marked measurements to the clipboard Delete Delete the selected measurement Alt X Exit X2 View RaySafe X2 View User Manual Hints MOUSE EVENT ACTION Mouse wheel up in waveforms area Zoom in Mouse wheel down in waveforms area Zoo
4. select Zoom in mouse scroll wheel up or mouse left click and drag Zoom out mouse scroll wheel down or mouse left double click resets the zoom and the section mark Pan left click and drag in the waveforms overview Mark a section and view details hold shift and left click and drag RaySafe X2 View User Manual View measurements Waveforms Time ms 4 Duration 12 9 Start time 2 2 Stop time 15 0 Tube voltage kV Min 67 18 Max 71 68 Average 69 11 z m S Dose rate mGy s Dose rate mGy s 35 40 Timeims 10 9 V Ml Tube voltage kv 70 2 V Ml Dose rate mGy s 3 8 Figure 11 Waveforms with a part selected You can save or copy the waveform as an image png format using the right click menu in the waveforms area 10 RaySafe X2 View User Manual Export measurements EXPORT MEASUREMENTS EXPORT TO EXCEL x Excel Connected Book T Sheet 7 BS cet active ca Export All T a Automatically export to Excel Figure 12 Excel export panel EXPORT TO EXCEL AS YOU MEASURE Follow the steps below to export each new measurement to Excel 1 Click Connect in the Excel area Connect 2 Select Excel settings workbook sheet start cell r r Get active cell 3 Verify that the box Automatically export to Excel is checked Automatically export to Excel Tip Click View Compact view in the menu or press Alt C to make the X2 View window narrow
5. 69 7 kVp 178 3 uGy 50 2 ms 406mm Alt 3 563 mGy s 1pulse 5 9 mm AI 1 mGy pu pulses 69 5kVp 180 9 uGy 50ims 406mmAlt 3 608 mGy s i pulse 6 0mm AII mGy pu pulses 69 6 kVp 182 7 uGy 50 2 ms 405mmAlt 3 641mGy s 1pulse 5 9 mm AI 1 mGy pu pulses 69 6 kVp 184 8 uGy 50 2 ms 406mmAlt 3 681 mGy s 1pulse 5 9 mm AI 1 mGy pu pulses 69 2 kVp 187 0 Gy 50 3 ms 404mmAIF 3 722 mGy s ipulse 5 8mm All mGy pu pulses 69 2 kVp 188 6 pGy 50 2 ms 405mmAlt 3 758 mGy s 1pulse 5 9 mm AI 1 mGy pu pulses a 4 r D D F D h Figure 8 Starred measurements Every measurement has an associated note field The notes are saved along with the measurements and are also exported to Excel Information Measurement 156 9 25 2012 09 48 Settings Notes Gray E X2 BaseUnit 4010 Dose unit 70 kV 0 1 mm Cu 167 cm FDD Stop delay lanare nremilzer N nulses E X2 R F Sensor 114 Figure 9 Information panel with Notes field VIEW WAVEFORMS Click on a measurement to see its waveforms The waveforms area consists of the waveforms and check boxes for showing hiding the different waveforms The dark line represents the average of the collected data and the lighter cloud is the range of data points Waveforms 8 a I I Tube voltage kV mR n Dose rate mGy s Timeims 0 0 E Dose rate mGy s 0 0 Figure 10 Waveforms panel You can analyze the waveform by zoom pan and
6. SURE Connect the base unit to X2 View with a USB cable Figure 2 Connect base unit with X2 View X2 View will show the status of the connected instrument in the setup panel to the left RaySafe X2 i i i Ke Base Unit Beam quality Generic Dose unit Gray Gy Stop delay Os Ignore prepulses 0 pulses Figure 3 X2 setup panel All new measurements will now be added to the measurement list in X2 View RaySafe X2 View User Manual Import measurements IMPORT FROM BASE UNIT If you have measurements in a base unit follow this instruction to import them to X2 View 1 Connect the base unit to the computer running X2 View 2 Select File Import from base unit in the menu or press F8 3 Select the measurement series you want to import and click Import selected Import all imports all measurements made the selected day Import measurements from base unit Date of measurement Sensor type Start time Stop time 4 p p X2R F Sensor amp mAs 08 07 09 25 ae ea ee X2 R F Sensor amp mAs 09 25 09 25 2 nf2 34 5 X2 RIF Sensor amp mAs 12 51 12 53 X2 R F Sensor amp mAs 13 06 13 19 X2 R F Sensor amp mAs Bee eae ee X2 R F Sensor amp mAs X2 R F Sensor X2 R F Sensor amp mAs os e Figure 4 Import window CONNECT USING BLUETOOTH OPTION If you have the X2 Base Unit Bluetooth adapter you can connect to the base unit wirelessly 1 Connect the Bluetooth adapter to a port marke
7. USER MANUAL RaySate X2 View WRaySafe 2014 01 Unfors RaySafe 5001089 2 All rights are reserved Reproduction or transmission in whole or in part in any form or by any means electronic mechanical or otherwise is prohibited without the prior written consent of the copyright owner RaySafe X2 View User Manual Contents CONTENTS PEO RANI IE E lle Wiad se saattsnnvciasaitsiads EEEE eet aot aiad damit A IMPORT MEASUREMENTS sosspneanannasionsanaanesaneannpndeanseaqnadaneaedansnennedoanannadteanngniancaein 5 Import as you MCCS Cs vic ncecewciconcrenciiencamncaemenunianas sansiachdausisdshiensuesbdaubiosbcasewanaete 5 ITS OTL ronm Dase UNa i EEEE oc eo ee 6 Connect using Bluetooth Option cece ceccsecescssesseeeeesseeneeesees 6 VIEW MF Po II EEIVIIE INS aracheanapsactarmasbachananieoceatner vunstsnsesnt ede ir ea e iE A 8 View measured values cscircsinsansiunncennyntonitueresediansecatannopnienatnntnanetacautatas anssintadawisanoites 8 NESE WAY GC UMI EN NE NEE EEE E EET 9 EAPORT MEASUREMENT varcranctonatesnain ach annacsaensndtceinautaseinuedsanitcataseanastnecinanaveentetnen 11 55 4016 O63 E Pen ee nee E nee renee ne ieee ere ee A 11 Export waveform IMAGE oo ce eccccccescescesscesecssccsecesecsecsscssecesecssceseesseeeeesees I gt D e TANS ENEE EET E NE EESE 13 MANAGE THE RAYSAFE X2 UIE IV asaras aiena i S E 14 Change programi SetINgS eee ee ee ener ee apreni raink Ri EAR EEE ene Tee 14 Change instrument settings 0
8. d SENSOR on the base unit 2 Select your base unit in the Bluetooth menu in X2 View Bluetooth A Select a base unit to connect Select a base unit to connect Ae Base Unit 193023 Ae Base Unit 193003 Ae Base Unit 193010 Search RaySafe X2 View User Manual Import measurements If no base units are found try searching by selecting Search in the Bluetooth menu Bluetooth a No base units found No base units found Search NOTE If Bluetooth does not appear in the Connections area your Bluetooth solution is not compatible with RaySafe X2 ry using a different Bluetooth adapter on your computer RaySafe X2 View User Manual View measurements VIEW MEASUREMENTS VIEW MEASURED VALUES You can view all measurements in a list overview or focus on one measurement at a time Toggle between the views using the buttons in the measurement panel ESES Measurements Sensor wy Tube voltage Dose Time Half value layer Dose rate Pulse rate wg Soren eS bday tone enna v picis 69 8 kVp 173 0 Gy 501ms 407 mmAlt 3 450 mGy s 6 0mm All pulses 70 0 kVp 175 2 uGy 501ms 408mmAlt 3 495 mGy s 1 pulse 6imm AII mGy pu pulses 69 5 kVp 176 9 uGy 501ms 407mmAlt 3 528 mGy s 1pulse 6 0 mm AI 1 mGy pu pulses 697 kVp 178 8 uGy 50 2 ms 406mmAlt 3 563 mGy s i pulse 5 9 mm All mGy pu pulses 69 5 kVp 180 9 uGy 501ms 406mmAlt 3 608 mGy s i pulse 6 0mm AI 1 mGy pu pulses 69 6 kV
9. m out Double click in waveforms area Reset zoom Left click and drag in waveforms area Pan Shift left click and drag in waveforms area Mark a section Ctrl left click and drag in waveforms area Select a region to zoom in to Right click Open a menu in the measurement or waveforms area TECHNICAL SUPPORT Please don t hesitate to contact our support desk if you have any questions Visit http www raysafe com for contact information 18
10. p 182 7 Gy 50 2 ms 405mmAlt 3 641mGy s 1 pulse 5 9 mm AI 1 mGy pu pulses 69 6 kVp 184 3 uGy 50 2 ms 406mmAlt 3 681mGy s i pulse 5 9mmAll mGy pu pulses 69 2kVp 187 0 Gy 50 3 ms 404mmAlt 3 722 mGy s ipulse 5 8mmAll mGy pu pulses 69 2kVp 183 6 uGy 50 2 ms 405mmAlt 3 758 mGy s 1 pulse 5 9 mm AI 1 mGy pu pulses a b h h H h a a a oe Figure 5 List view of measurements 69 8 wp 173 0 o 50 1 4 07 mam 3 450 mays ie 6 0 mm Al TF mGy pulse pulses s s 4 i h f F H 6 H r a a a a Figure 6 Single measurement view You can also enlarge one parameter to be able to see the value from a longer distance Click on a parameter to enlarge click again to see all parameters Measurements Figure 7 Single parameter view In the parameter list you can also add a star to measurements of your choice You can export starred measurements to Excel See Export to Excel 11 RaySafe X2 View User Manual View measurements oo om Measurements m m Sensor wy Tube voltage Dose Time Half value layer Dose rate Pulses Total filtration Dose per pulse Pulse rate EEI miiia Cimin midesi bonnn napona EPE PEDS p 69 8 kVp 173 0 Gy 501ms 407 mmAlt 3 450 mGy s 1pulse 6 0mm AII mGy pu pulses 70 0 kVp 175 2 wGy 501ms 408mmAlt 3 495 mGy s 1pulse 6immAIlT mGy pu pulses 69 5 kVp 176 9 uGy 501ms 407mmAlt 3 528 mGy s 1pulse 6 0 mm AI mGy pu pulses
11. ress Ctrl Shift S to save a file with a new name The file is saved in X2 View format x2v RaySafe X2 View User Manual Manage the RaySafe X2 system MANAGE THE RAYSAFE X2 SYSTEM CHANGE PROGRAM SETTINGS Click File Settings or press F4 to reach the program settings under the General tab Settings General Sensors Sound Play a sound after each new measurement Excel Export in standard format Export in RaySafe Xi View format Default start cell Al Figure 14 Program settings window The main difference between the standard and the RaySafe Xi View export format is the order of the columns Select RaySafe Xi View format for backward compatibility with your old Xi View Excel templates Change the desired settings and click Save RaySafe X2 View User Manual Manage the RaySafe X2 system CHANGE INSTRUMENT SETTINGS You can only change settings for a connected sensor Click File Settings or press F4 to reach the detector settings For explanations of the different instrument settings see the information texts in the base unit General Sensors Beam quality Generic Ignore prepulses 0 pulses Figure 15 Sensor settings window Change the desired instrument settings and click Save 15 RaySafe X2 View User Manual Manage the RaySafe X2 system UPDATE THE RAYSAFE X2 SYSTEM X2 View will automatically connect to X2 Online when your computer is connected to the
12. to see more of the Excel window when exporting as you measure EXPORT MEASUREMENTS TO EXCEL AFTERWARDS Use the Excel Export button to export measurement afterwards 1 Click Connect in the Excel area Connect RaySafe X2 View User Manual Export measurements 2 Select Excel settings workbook sheet start cell Book al Sheet on B 3 Inthe drop down list select what to export Selected All Starred or the Waveforms of the selected measurement Export All k 4 Press the Export button EXPORT WAVEFORMS TO EXCEL Use the Excel Export button to export waveforms 1 Click Connect in the Excel area Connect 2 Select Excel settings workbook sheet start cell Book il Sheet on B 3 Inthe drop down list select Waveforms Export Waveform r 4 Press the Export button 12 RaySafe X2 View User Manual Export measurements EXPORT WAVEFORM IMAGE Right click in the waveform area and select Save as image to save the waveform in png format or select Copy to put it as an image in the clipboard for pasting into a document Tube voltage kV S amp L 1 Dose rate mGy s 1 T T T T i T T T T T T T 1 i 1 75 20 0 225 25 0 275 30 0 ms Figure 13 Waveform with a certain part zoomed in copied in png format SAVE FILE Click File Save in the menu or press Ctrl S to save a file with all measurements notes and stars Click File Save As in the menu or p

Download Pdf Manuals

image

Related Search

Related Contents

45% - Element14  Sandberg Pocket Bluetooth Keyboard Nordic  NOTICE D`UTILISATION SALAD`BAR FROID SB 40 F  Piano di sicurezza e coordinamento - Bandi on-line  主な部品交換方法(取扱説明書より抜粋)pdf  Craftsman C583-930360 Operating Instructions  Participer à l`étude de l`université de Toronto, pour mieux connaitre l  manual do proprietário  Cuisson sécuritaire Niveaux de friture Réglage du capteur de friture  Minka Lavery 71163-143C Instructions / Assembly  