Home

VTO2 Series User`s Manual V1.0.0 201407

image

Contents

1. Save amp Cancel Appendix 4 7 e Add VTH Step 1 In VTMS main interface select Device click on Batch Add system pops up Batch Add box Step 2 Fill in info according to your actual condition and click on Save See Appendix 4 8 Device Type s VTH VTH type Digital Manufacturer dahu Community s 1 Building Building 1 Unit Unit 1 Floors per unit 10 House per floor Appendix 4 8 Appendix 5 Toxic Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Circuit Board Component Device Case Wire and Cable Packing Components Accessories o 9 e j O Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process suc
2. a Appendix 4 1 Config Network Address Appendix 4 2 Create Organization Appendix 5 Toxic or Hazardous Materials or Elements Important Safeguards and Warnings Please read the following safeguards and warnings carefully before using the product in order to avoid damages and losses Note Do not expose the device to lampblack steam or dust Otherwise it may cause fire or electric shock Do not install the device at position exposed to sunlight or in high temperature Temperature rise in device may cause fire Do not expose the device to humid environment Otherwise it may cause fire The device must be installed on solid and flat surface in order to guarantee safety under load and earthquake Otherwise it may cause device to fall off or turnover Do not place the device on carpet or quilt Do not block air vent of the device or ventilation around the device Otherwise temperature in device will rise and may cause fire Do not place any object on the device Do not disassemble the device without professional instruction Warning Please use battery properly to avoid fire explosion and other dangers Please replace used battery with battery of the same type Do not use power line other than the one specified Please use it properly Ot
3. 2 2 3 Installation Step Step 1 Dig a hole on wall its dimension is 117 128 80 mm See Figure 2 5 Step 2 Embed metal bracket into wall until its four peaks lean against the wall See Figure 2 6 Step 3 Align the device on metal bracket according to screw hole At 2 spots fasten screws M3x8 Cross recessed countersunk head tail machine screws galvanizing white and fix device on metal bracket See Figure 2 7 128 HEHHE HHH Figure 2 7 Power supply connect to lock door sensor and User Port unlock button 2 1 Project Port Reserved for project staff use 2 4 Electric Control Lock and Electromagnetic Lock 2 4 1 Electric Control Lock When VTO connects to electric control lock it means that the positive end of electronic control lock connects to NO of VTO user port 10 while its negative end connects to COM of VTO user port 12 When VTO connects to unlock button one end of unlock button connects to BUTTON of VTO user port 7 while the other end connects to CND of VTO user port 9 See Figure 2 9 1 2 3 o4 6 Te UNLOCK Figure 2 9 2 4 2 Electromagnetic Lock When VTO connects to electromagnetic lock it means that the positive end of electromagnetic lock connects to NC of VTO user port 11 while its negative end connects to COM of VTO user port 12 When VTO connects to door sensor in electromagnetic lock one end of door sensor connects to FEEDBACK o
4. UU TET 4 2122 EAN GONG M MEN 5 Aco 5 4 4 242 28262242 226222 iN e Nt S 022 2 6 4 125 Ideo me uu es 7 4 1 0 568 8 TIT UT TS 9 42 0 u ens 9 242 2 _AlIWHBSCOG 9 4 9 SAS lle S 10 4 3 1 10 au 10 5 Basic FUNCHON 0016 ed u bnc a 11 Bali 11 5 1 1 Cal Manager uu m 11 1 2 12 Slo 8 E askani 12 15 mau gsm Don 15 5 4 16 Su s ayna Au M Ci a Ed 16 36 Restore BaCKUD 16 6 gione 17 Appendix 1 Technical Specifications 18 Appendix 2 Technical 5 1 Appendix 2 1 Cable 1 Appendix 2 2 Power Extension Line Specification 1 Appendix 2 3 Embedded 1 APPEND 2 Appendix 4 VTMS Client
5. Logout Figure 4 11 4 4 Logout Here you can reboot device or logout Click on logout to log out the system and it returns to login page 5 Basic Function Introduction 5 1 Call Function 5 1 1 Call Manager Center Check Register to the MGT Center you can touch the Call button to call manager center Now VTO can only call MGT Center cannot call VTH Manager center s time can be set on management platform or villa VTO s web end Once manager center picks up the call you can perform a visual bidirectional talk with the manager center You can touch the button on VTO to end call at any time Step 1 According to configured for the center fill in building no building unit no and VTO no otep 2 In LAN Config check register to the MGT center as in Figure 5 1 Step 3 Fillin MGT center IP address and MGT port no otep 4 Set call VTS time Within this period VTO can only call the center otep 5 Check Call VTS or not otep 6 Confirm all config and click on OK Enter Logout Reboot Devices to manually reboot the device Local Config Building 11 Indoor Manager Building Unit 1 Video Set VTO No 5901 C Group Call User Manage gt gt Network Config Info Search EM Centre IP Address 10 22 5 254 Register to the Centre Status Statistics Logout PortNo 12801 Call VTS Time 23 Call VTS Or Not Warning The device needs reboo
6. amp C Manager System Time Contig Manager gt m gt LAN Config Video Format WVGA v Device Type Villa Station k unes Frame Rate 25 RebootDate Tuesday v gt Network Config gt Video Set Sensitivity of fill lightto open 60 Version Info gt User Manage Info Search Default Refresh OK Status Statistics Logout Figure 4 1 Parameter Video Format Set video format that collected by the camera including WVGA and D1 WVGA resolution is 800x480 D1 resolution is 704x576 Device Type Display device type Frame Rate NTSC 30 fps PAL 25 fps Reboot Date On the set date device will automatically reboot Sensitivity of fil Set threshold of light light to open Version Info Display device version info Default Only restore current Local Config page to default settings 4 1 1 2 A amp C Manager System Config Local Config A amp C Manager System Time Config Manager LAN Config Unlock Responding Interval 15 Door Sensor Check Time 30 Check Door Sensor Signal Before Lock Indoor Manager 5 Unlock Period 2 Network Config Video Set User Manage Default Refresh Figure 4 2 Unlock Responding The interval between current unlock and next one Interval unit is second Unlock Period Period door remains unlocked unit is second Door Sensor Check When only use door sensor check Check Door Time Sensor Signal Before Lock Set Door Sensor Check Check Door Senso
7. TMS you can see VTMS is successfully configured as in Appendix 4 4 VTS successfully connected Appendix 4 4 Appendix 4 2 Create Organization First you must build up environmrnt and set VTMS server please refer to Appendix 2 This chapter takes example of a residence with 10 buildings and 2 units e Create Residence Organization Step 1 In VTMS main interface select Organization click on Batch Add System pops up Batch Add box see Appendix 4 5 Device Status 3 Device MGR Batch Add J Batch Delete Upper SN Community 01 Upper Name Community 1 Batch parameter A total of 10 building s each with 2 unit s OK Cancel Appendix 4 5 Step 2 Click on OK to save The created organization is as in Appendix 4 6 Device Status EX Device MGR Contract All Expand All Name only Refresh Current Node Organization Zone SN Community 01 n Name Community 1 RR Building 1 Address Community 1 Q Building 3 Add gt Modify Batch Add Batch Delete Appendix 4 6 e Add VTO Step 1 In VTMS main interface select Device click on Add system pops up Batch Add box Step 2 Fill in info according to your actual condition and click on Save See Appendix 4 7 SN Mame x Type Manufacturer Position Net Address Sub Net Gate Way Met Port Switch Recieve Notice Comments
8. VTO2 Series User s Manual V1 0 0 Table of Contents Ta DIS Gl u uuu l mm 2 1 Product OI IU RE 1 DS 1 5 000065 1 23 LE 1 122 1 0 cuui nw eS iue ere ee 1 b2 1 t22 uu 2 leo Rear 3 1 3 System tt endi ec ton t tet 3 1 3 1 X One to One 5 2 2 04 1441118 0060 3 13 2 XOne Multipl 4 133 GOP Call SCCM Cece ci oe eo eI ate ta 4 2 UC EE 6 IDIRCCUMSTAN 81 112 rm 6 MERO 6 2 1 2 wists ete 6 2 1 3 7 22 01 18 8 uu u 9 22 ETON 9 Dimensi 10 229 Installation SlOD usen u acacia 10 zug ayasa 12 2 4 Electric Control Lock and Electromagnetic Lock 13 2441 Electric Gontiol 13 242 Electromagnets densidad 13 3 068016 01 a aa ua a ss ss 1 1 292 General GON acido seas u namn 2 4 VV Mla teeta ae AERE EDEN 4 SVS Pe WA GOLI 4
9. d User Username Password confirm Remark Figure 4 7 e Modify User In User Manage interface click on system pops up Modify User interface Check Change Password and change password and remark see Figure 4 8 Modify User Old Password Hew Password Confirm Remark admin s account Figure 4 8 e Delete User In User Manage interface click on to delete user 4 2Info Search 4 2 1 Call History Here you can view call history of VTO in Call History interface It can save up to 1024 items System Config VTO Call History Info Search gt Call Type Room No Begin Time Talk Time m End State gt Alarm Record Status Statistics Logout Figure 4 9 4 2 2 Alarm Record You can search VTO alarm record on Alarm Record interface with storage up to 1024 items See Figure 4 10 System Config Alarm Record Info Search gt C Room No Event State Channel Begin Time Call History gt Status Statistics Logout Figure 4 10 4 3 Status Statistics 4 3 1 VTH Status Here you can view connection status of VTH e Status Offline VTO and VTH are not connected you cannot call monitor talk or etc Online VTO and VTH are connected you can call monitor talk and etc e MON e Unmon VTH is not monitoring e Onmom VTH is monitoring oee Figure 4 11 System Config VTH Status Info Search Status Statistics Reg Time Off Time 192 168 1 108 0
10. ery half hour VTO automatically saves card and VTH info in the system If you want to restore card and or VTH info you must restore within half hour after your last operation that change these info FAQ Q pressed Call button and the indicator turned on but the V TO did not start a call A Please check your operation process Q How to end a call when am calling A Please press button on VTO and there will be sound from the device Q The device could not boot up and there was no sound or light A Please check if power supply is well plugged Q My call did not go though A It is network connection error please check the cables of the device and its extension Q have other problems not included above A Please contact technical staffs for assistance Appendix 1 Technical Specifications Model VTO2000A Embedded micro controller oystem Embedded Linux os Video Compression H 264 Video Standard Single key input Operation en Support optional Status Check PP P Ethernet 10M 100Mbps self fit N etwor etwor TCP IP Protocol DC 107 15 Standby lt 1W working lt 10W General Support bidirectional talk Working 30 C 70 C Temperature Relative ue 10 90 RH Humidity 129 9mmx32 2mmx140mm LxWxH Weight 0 8kg Appendix 2 Technical Specifications Appendix 2 1 Cable Specification The wiring length between VTO and VTH is Ln so reasonable specif
11. essed countersunk head tail machine screws galvanizing white 18 Cross recessed countersunk head tail tapping screws galvanizing white White expansion tube 6x30mm Chart 2 1 Note M3x6 or M3x8 either is OK 2 1 2 Dimension Before you install the device please make sure you know the dimension of device and select appropriate installation method See Figure 2 1 Figure 2 1 2 1 3Installation Step otep 1 Install metal bracket into the groove on wall At spot 1 fasten screw ST3x18 Cross recessed countersunk head tail tapping screws galvanizing white and fix metal bracket on wall See Figure 2 2 otep 2 Align the device on metal bracket according to screw hole At spot 2 fasten screw M3x8 Cross recessed countersunk head tail machine screws galvanizing white and fix device on metal bracket See Figure 2 3 Figure 2 2 Figure 2 3 2 2Embedded in Wall 2 2 1 Screw Before installing VTH please check screws on accessory bag according to the following specifications and install by following this guide M3x6 Hex slot pan head tail machine 4 screws galvanizing white M3x8 Cross recessed countersunk head tail 4 machine screws galvanizing white Chart 2 2 Note M3x6 or M3x8 either is OK 2 2 2 Dimension Before you install the device please make sure you know the dimension of device and select appropriate installation method See Figure 2 4 115 Figure 2 4
12. f VTO user port 8 while the other end connects to GND of VTO user port 9 See Figure 2 10 Figure 2 10 3 Installation Debugging Warning e Before debugging the staff shall be familiar with device s installation wiring and usage e Beore debugging check wiring for short or open circuit When staff find each circuit is normal plug the device to power e After debugging clear the site 3 1 WEB Setup If you first use VTO you may need to operate according to the following steps Step 1 First make sure your PC and the VTO are well connected and follow steps below to login WEB interface otep 2 In Internet Explorer input IP address of the VTO and press Enter System shows Figure 3 1 Step 3 Input Username and Password Step 4 Click on Login Note Default address of VTO is 192 168 1 110 Default username and password 15 admin admin After first login please change your password IP VDP Door Station Web Server V1 0 Figure 3 1 3 2 General Config If you first use VTO you may need to operate according to the following steps otep 1 In Internet Explorer input IP address of the VTO and press Enter Note Default IP address of VTO is 192 168 1 110 Default username and password is admin admin After first login please change your password Step 2 In WEB interface select System Config gt Local Config set video format as WVGA as in Figure 3 2 Local Config A amp C Manager System Time C
13. h kind of substances or elements please return to the corresponding local authorities to process according to your local government statutes Note e This manual is for reference only Slight difference may be found in user interface e All the designs and software here are subject to change without prior written notice e All trademarks and registered trademarks are the properties of their respective owners e fthere is any uncertainty controversy please refer to the final explanation of us e Please visit our website or contact your local service engineer for more information
14. herwise It may cause fire or electric shock Special Announcement This manual is for reference only All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website for more information 1 Product Overview 1 1 List of Models key 1 2 Structure 1 2 1 Dimension Before you install the device please make sure you know the dimension of device and select appropriate installation method See Figure 1 1 x 129mm 221 32 2mm 140mm Figure 1 1 1 2 2 Front Panel Figure 1 2 Mic Audio input It monitors corresponding door region Light compensation will automatically turn on Compensation during monitoring calling or connecting status if there is no enough light in environment Audio output User Nameplate Display username and other info Call Button Call center or VTH 1 2 3 Rear Panel Figure 1 3 Component Name Camera Angle 9 Adjust camera angle Adjustment Vandal proof When VTO if forced to leave wall it will alarm and Switch report to MGT center Via convertor connect network cable RJ45 Network Port crystal head Connect to lock door sensor feedback and unlock User Port Buren 5 Project Por
15. ication of wiring is Cable Specification O lt Lys50m 50 lt Lys100m UTP Cat5e Cat6 10 ohm 100m Optional Optional UTP Cat5e Cat6 18 8 ohm 100m Optional Not optional Note Please do not let Ly be over 100m Appendix 2 2 Power Extension Line Specification The wiring length between VTO and adaptor is Lc so reasonable specification of extnsion line is Extension Line Specification O Lcx30m 30 Lcx100m 20AWG Optional Not optional 17ANG Note Before plugging extension line to power make sure its positive and negative end are correctly wired Appendix 2 3 Embedded Box VTO Model Embedded Box VTO2000A Case 126 115 Appendix 3 5 e Check Installation Environment This manual makes Window XP as example to introduce how to modify of PC inorder to connect VTMS and monitoirng system Step 1 Select Start gt Control Panel gt Network Connection gt Local Area Connection right click on Local Area Connection icem select Properties see Appendix 3 1 ocal Grea Connection Connected F iraadcom Disable Status Repair Bridge Connections Create Shortcuk Rename Properties Appendix 3 1 Step 2 View and modify IP address make it in the same segment with VTO See Appendix 3 2 Local Area Connection Properties Internet Protocol 911114 Properties General Connect using BE Broadcom Gigabit Cc This connection uses the following item
16. ideo Set gt User Manage Info Search Status Statistics Logout LAN Config Building No 01 Building Unit No 1 VTO 5901 Group Call MGT Centre IP Address 10 22 5 254 Register to the MGT Centre 12801 Call VTS Time To 23 Call VTS Or Not Warming The device needs reboot after modifing the config above Default Figure 5 3 Set Main VTH Step 1 On VTH screen press System Settings gt Project Settings input password default is 002236 to enter Project Settings interface otep 2 Press Product Info input Room No Local IP and etc as in Figure 5 4 Note Room No Must match setting in VTH Short No In Figure 5 4 isi Project Settings a Local IP 172 105 Network subnet Mask 255 255 um PC Info Gateway 172 Default Version 4 Back Figure 5 4 Step 3 Press Network input VTO IP Address See Figure 5 5 Project Settings 1 Product Info Main Name Main VTO Device Type VTO Middle m C Info VTO IP Address 172 3 Default Network Port Enable Status 9 Back Figure 5 5 Set Extension Step 1 On VTH screen press System Settings gt Project Settings input password default is 002236 to enter Project Settings interface Step 2 Press Product Info Press Master Master icon becomes Extention icon Step 3 Set Room No i e 1101 1 input IP Address Subnet Mask and Gatewa
17. on Start service and VTMS will boot up process mysql configure Stop service 1 Image CPUT memory K Threads Process ID Parent ID Priority 0 31 mysald zwan exe 11 18 2013 09 00 53 0 13484 30 548 8 java_zwan exe 11 18 2013 08 01 01 0 129692 169 3016 816 8 VTS_PMU exe 11 18 2015 09 01 21 0 9980 19 3660 816 8 Appendix 3 4 Appendix 4 VTMS Client This following mainly introducts how to config VTMS Client Appendix 4 1 Config Network Address Step 1 Install VTMS Client on PC Step 2 Double click on IMS exe in pop up box input username password IP address port and etc Click on Login See Appendix 4 1 Note Default username and password is admin and 123 respectively After first successful login please change password Vision Telephone Manage System name admin pwa xke 172 5 1 107 port 8787 auto login save pwd Appendix 4 1 Step 3 In main interface click on Device See Appendix 4 2 Organization Device MGR Appendix 4 2 Step 4 Double click on VTS parameter collumn sustem pops up Edit device box input PC s IP address See Appendix 4 3 SN 330103000000800053 Name VTS Type VTS 1 Manufacturer Dahu Net Address 172 5 1 107 Net Port 12801 Comments Appendix 4 3 Step 5 Click on Save Input project password default project password is 123 Step 6 Re login V
18. onfig Manager Video Format Device Type Villa Station Sensitivity of fill ightta open 60 Versian Info Figure 3 2 Step 3 In System Time tab click on Sync PC to make VTO time the same with PC Step 4 Select System Config gt Network Config set VTO IP Subnet Mask and Default Gateway See Figure 3 3 IP Address 10 15 6 141 subnet Mask 255 255 0 0 Default Gateway 10 15 0 1 MAC Address Default Refresh Figure 3 3 Step 5 Optional If VTO connects to VTMS platform System Config gt LAN Config set Area No Section No Building No and etc These parameters must match settings on VTMS Client as in 5 RR AJ5 HW Please refer to Appendix 2 and 3 See Figure 3 4 LAN Config Building Mo 01 Building Unit Ma 1 6901 Group Figure 3 4 SN Name Type VTO 7 Manufacturer dahu x Net Address Sub Net Gate Way Net Port Switch Recieve Notice Comments Figure 3 5 Note When you configue one to multiple scene different VTOs shall have different VTO no and same building no and unit no in order to form a proper network 4 Web Config This chapter introduces VTO WEB interface and its parameters and hot to configure them 4 1 System Config 4 1 1 Local Config 4 1 1 1 Local Config In Local Config interface you can view VIO model version info and etc System Config Local Config A
19. or Manager Video Set User Manage Info Search Status Statistics Logout 4 1 5 Video Set Network Config IP Address subnet Mask Default Gateway WAC Address Figure 4 5 Config 10 15 6 141 255 255 0 0 10 15 0 1 You can set video effect and volume in Video Set interface See Figure 4 6 System Config Video Set Local Config LAN Config Indoor Manager gt gt gt gt Network Config gt gt User Manage Info Search Status Statistics Logout Default Open Door Parameter Figure 4 6 Brightness Contrast Hue Saturation GainAuto SceneMode Day Night Mode BackLight Mode Mirror Flip VTO Mic Volume VTO Beep Volume 0 50 0 50 0 50 0 50 90 Automatic Colorful v Disabled 12 O on ott O on of 90 0 80 Gain Gain limit of video basic parameter Scene Mode Day Night Mode Back Light Mode Select mode automatic sunny night and etc Back light for special environment Mirror Make image displayed in mirror Display image in VTO Mic Volume Set VTO MIC volume size VTO Beep Volume Set VTO beep volume size Default Heset video effect and volume to default Unlock via web 4 1 6 User Manage Only when you login as admin you can add modify delete and view user info in User Manage interface Add User In User Manage interface click on Add User system pops up Figure 4 7 Fill in user info Ad
20. r Time to enable it Signal Before Lock When door remains unlocked over set door sensor check time it alarms 4 1 1 3 System Time Here you can set date format time format and input system date and time You can also click on Sync PC to synchronize system time with PC time 4 1 2LAN Config Here you can register VIO to center and set how to call center Please refer to Call MGT Center 4 1 3 Indoor Manager In Indoor Manager interface you can add VTH digital indoor station view VTH info and delete VTH System Config Indoor Manager Local Config Digital Indoor Station Manager FamilyName FirstName Nick Name Room No IP Address Card No Info 192 168 1 108 LAN Config Network Config Video Set gt gt gt gt gt User Manage Figure 4 3 Add VTH In Indoor Manager interface click on Add The system pops up a window as in Figure 4 4 FirstName Nick Name VTH Short Ma IP Address Figure 4 4 Fill in VTH info as user s name VTH short no and IP address Note VTH short no consists of four digits the first two digits can be within 01 99 the last two digits can be within 01 16 Note Parameters with are mandatory 4 1 4 Network Config Here you can set VTO IP address Subnet Mask and Default Gateway After you have modified IP address Web page will reboot and go to the new IP address web page See Figure 4 5 System Config Local Config LAN Config Indo
21. s pn Client for Microsoft Networks File and Printer Sharing For Microsoft Mat dal 005 Packet Scheduler Internet Protocol T Description Transmission Control Protacal Intermet Protocol wide area network protocol that provides comm across diverse interconnected networks Show icon in notification area when connecter Notify me when this connection has limited You can get settings assigned automatically if pour network supports this capability you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically gt Use the following IP address IP address 10 15 subnet mask 255 255 Default gateway 10 15 8 Use the folowing DNS server addresses Preferred ONS server Alternate DNS server Appendix 3 2 Step 3 After complete modification select Start gt Run input cmd click on OK Enter command interface input ping IP of the VTO If it obtains communication data then VTO and the PC are connected See Appendix 3 3 ex C WWINDOWS system3 cmd exe Microsoft Windows XP Uemsion 5 1 2600 KG Copyright 1985 26801 Microsoft Corp C Documents and Settings 10881 gt 16 22 5 189 Appendix 3 3 e Enable VIMS The following mainly introduces how to config V TMS for you to login VTO and use VTMS Step 1 Install VTMS on PC Step 2 Double click z _gard click
22. t Reserved for project staff use 1 3System Networking This chapter mainly introduces usage of digital VIO please read the following content and install the device according to your actual condition 1 3 1 One to One Scene Visitor press Call button to call residence as VTH or Center See Figure 1 4 Cat 5 VTH 4 0m E Door Electric Unlock Sensor Lock Button PN Cable Lock Figure 1 4 1 3 2 Scenes In general user installs VTO at entrance of building and installs in resident s room as second confirmation device Visitor can call any resident via the VTO and the resident being called can unlock to allow the visitor entering the building Then the visitor call the resident to unlock room door again via second confirm VTO See Figure 1 5 Entrance Cat 5e Figure 1 5 1 3 3 Group Call Scene When visitor press Call button on VTO multiple VTHs will ring at the same time User can call hang up and unlock on any of these VTHs Note VTH has 1 master VTH and up to 3 extension VTHs See Figure 1 6 Figure 1 6 2 Install 2 1 Direct Installation 2 1 1 Screw Before installing VTH please check screws on accessory bag according to the following specifications and install by following this guide Component Name Illustration Quantity M3x6 Hex slot pan head tail machine screws galvanizing white M3x8 Cross rec
23. t after modifing the config above Default Refresh Figure 5 1 5 1 2 Call User Press Call button under standby status and the VTO will call user User may monitor VTO from VTH e On VTH press Unlock button to unlock door e When VTH picks up you can start talk with the VTH f no one answers the call then the call will end automatically and device returns to standby status 5 1 3 Group Call Group call is mainly used for one VTO Press Call button on VTO to call multiple VTH at the same time VTH consists of master VTH and extension VTH A system can only have a max of 1 master VTH and 5 extension VTHs Please refer to VTO2000A Series Installation Guide V 1 0 0 Set VTO Step 1 Select System Config Indoor Station Manager system shows Indoor Station interface Step 2 In Indoor Station Manager interface click on 2 to delete default V TH Step 3 Click on Add input VTH Short No IP Address optional to add a VTH See Figure 5 2 Note In Indoor Station interface you only need to add main VTH and you do not need to add extension Note FirstName Mick Name VTH Short No IP Address Figure 5 2 Paramete with are mandantory to be set Step 4 In LAN Config interface check Group Call and click on OK See Figure 5 3 otep 5 After config is complete enter Logout interface to reboot VTO System Config Local Config gt gt gt Indoor Manager gt Network Config gt V
24. y Step 4 In Master IP input of the main VTH After competion extension will automatically sync with main VTH info configured by user See Figure 5 6 l Project Settings 1 Room 102 1 Extension L Product Info Local IP ie 106 Network Subnet Mask 255 i 0 PC Info Gateway 1 MAC Default Version 4 Back Master IP 172 Figure 5 6 5 2 Monitor Both VTS and VTH are able to monitor this VTO by enabling the camera to capture local circumstance 5 3Unlock Function Unlock by Center When center is called calling or monitoring center can remotely unlock door VTO will return to standby interface after call ends or countdown stops Unlock by VTH When VTH is called calling or monitoring VTH can remotely unlock door VTO will return to standby interface after call ends or countdown stops 5 4 Compensation of Light In dark environment or at night the VTO adopts auto photoreception technology which achieves light compensation in connecting status 5 5 Vandal Proof There is one channel of vandal proof which will generate alarm sound and report to the manager center once VTO is forced to leave the wall 5 6 Restore Backup Restore Card Info If you encounter abnormality with card info or accidently restore default settings you can restore card info with this function Restore VTH Info If VTH info is mistakenly changed you can restore VTH info with this function Note Ev

Download Pdf Manuals