1. 2000 AR2 Addressable Double Input Module INSTRUCTION MANUAL E GENERAL The S2000 AR2 Addressable Double Input Module hereinafter referred to as the S2000 AR2 or the module is designed to connect one or two monitored circuits with included dry contact both NO and NC fire or intrusion detectors into the multiplex addressable Polling Loop PL of a S2000 KDL controller The S2000 AR2 receives control signals from interfaced detectors and transmits alarm conditions to the S2000 KDL The S2000 AR2 module is supplied with power and communicates data with the S2000 KDL over the polling loop The version of the AR2 software is 1 00 The S2000 AR2 supports DPLS_v2 xx data communication protocol providing measuring voltage of the polling loop at the point of its location The S2000 AR2 is designed for round the clock operating The module is not suitable for operation in corrosive and dusty environments as well as in fire hazardous and explosive areas INDICATION The S2000 AR2 is equipped with a red LED on its cover LED behavior depends on zone parameters programmed for this S2000 AR2 in the S2000 KDL configuration to give more information please refer to the S2000 KDL Manual The given Device Indication Control parameter defines whether the LED will operate in accordance with its own local tactics or with the logic of the master S2000 KDL The indication can also be disabled by the S2000 KDL at all LED indication depending on the S2000
2. Device Address command specifying a required address as the parameter Then open the module enclosure and press the button on the PCB three times long more than 1 s each and then one time short less than half second The address will be assigned to the first detector loop of the S2000 AR1 the second detector loop being automatically assigned to an incremented number The message about detecting the device with the newly assigned address shall be displayed by a network controller S2000 M or UProg Configuration Tool Please be attentive to avoid configuration conflicts Programming the S2000 KDL to Operate the S2000 AR2 To handle signals from a S2000 AR2 correctly the S2000 KDL controller the module is connected to must be programmed with the proper Zone Type parameters for this S2000 AR2 To program the S2000 KDL connect it to a PC under UProg Configuration Tool and follow the relevant programming instructions in accordance with the S2000 KDL User s Manual Set Zone Type parameter to the value 2 Combined Fire Alarm Loop for fire detectors and to one of the values 4 Intrusion Alarm Loop 6 Auxiliary Alarm Loop 7 Entrance Alarm Loop or 11 Panic Alarm loop for intrusion detectors 2000 AR2 ROUTINE TESTING Test the S2000 AR2 module by doing the following Step 1 Arm the first monitored circuits with brought detectors by means of a network controller either S2000 S2000M console or Orion PC Step 2 Simulate the det
3. 000 AR2 occupies two adjacent loop addresses The address is assigned to the first monitored circuit of the module the second monitored circuit being assigned automatically to the incremented number The default factory value of the S2000 AR2 loop address is 126 127 Moreover a monitoring strategy must be defined which will be used by the S2000 KDL controller while processing signals received from the S2000 AR2 Programming the S2000 AR2 Address within the S2000 KDL Polling Loop An S2000 AR2 module is supplied with the default loop address of 126 127 This address value can be changed using either S2000 M console tools or the UProg Configuration Tool In order to program the unique S2000 AR2 loop address connect the module to a S2000 KDL controller which is in turns connected to a network controller a S2000 M console or PC under UProg software Then send one of the following commands to the S2000 KDL controller for getting more information see the relevant User s Manual Change the Device Address Use the Change Device Address command specifying the old module address and the new module address as the parameters See more information in the referred Manuals The network controller will display the messages about disconnecting the device with the old address and then detecting the device with newly programmed address Program the Device Address If the device address is unknown or two devices have the same address then use the Program
4. KDL logic is described in the S2000 KDL Manual The local S2000 AR2 indication tactics is as follows LED doesn t light No power is supplied via the polling loop LED is lit steady The module has been supplied with power but the S2000 KDL has not yet polled the module LED flashes once per four Both monitored circuits are in Norm conditions see Table 1 seconds LED double flashes once per One or both monitored circuits are out of norm see Table 1 Depending on four seconds the value of the Zone Type parameter programmed for this S2000 AR2 in the 2000 KDL configuration this can mean fire intrusion or trouble conditions LED quadruple flashes once The S2000 KDL has switched the S2000 AR2 into the Address Programming per four seconds Mode SPECIFICATIONS Input Voltage over the polling loop of a S2000 KDL 8 10 VDC Current Consumption over the polling loop of the S2000 KDL 1 mA max Pre operation Time 15 s max Operating Temperatures 30 to 50T Transport Storage Temperatures 50 to 50 Ingress Protection Rating IP41 Humidity 93 at 40 C non condensing Overall Dimensions 56 mm x 33 mm x 20 mm max Weight 40 g max Average Lifetime at least 10 years STANDARD DELIVERY Find the following unpacking the S2000 AR2 2000 AR2 Module 2 EOL Resistors MF 1 4W 10k 5 2 Woodscrews 2 Wallplugs This Instruction Manual one per ten S2000 AR2 VVVV V STANDARD WIRING DIAGRAMS The Figure 1 below shows wiri
5. LESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty gives you specific legal rights and you may also have other rights which vary from country to country No increase or alteration written or verbal to this warranty is authorized
6. ector response Ensure the module LED double flashes once per four seconds while the network controller indicates a Fire Alarm or Intrusion Alarm message for this monitored circuit Step 3 Recover normal conditions and ensure the module LED returns to single flashing once per four seconds Step 4 Reset the alarm by means of the network controller Repeat Steps 1 to 4 for the second monitored circuit of the S2000 AR2 module If the network controller has displayed no intrusion or fire condition messages said above or the module indication differs from that said above then the module is defective and must be replaced You can additionally inspect the parameters of the monitored circuits having measured their ADC values which correlate with resistance values of the monitored circuits see Table 1 below Table 1 Match between monitored circuit resistances or ADC value and statuses of the monitored circuits Short circuit D2 response Norm D1 response Open failure or D3 response Variant B Variant A or D4 response Variant C Variant C Resistance kQ 0 to 1 9 2 5 to 6 2 6 5 to 14 15 to 46 50 and above ADC value 0 to 10 12 to 29 31 to 58 63 to 121 125 to 230 ZAO NVP Bolid 4 Pionerskaya Sir Korolev 141070 Moscow Region Russia Phone fax 7 495 513 32 35 Email info bolid ru overseas bolid com www bolid com SECURITY SYSTEMS BOLID ONE YEAR LIMITED WARRANTY Bolid Company and its divisions and subsidia
7. ng but not limited to any implied warranty of merchantability must be brought within 12 months from date of original purchase In no case shall seller be liable to anyone for any consequential or incidental damages for breach of this or any other warranty express or implied or upon any other basis of liability whatsoever even if the loss or damage is caused by the seller s own negligence or fault Some countries do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller does not represent that the product may not be compromised or circumvented that the product will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARD
8. ng the S2000 AR2 to the polling loop of the S2000 KDL as well as standard variants for wiring non addressable conventional zone type dry contact detectors to the S2000 AR2 monitored circuit detector loop contacts DL1 and DL2 Di Ri ReoL Variant A D4 fire detector with NC contact Zone Type Detector Variant A B or C D2 Reol pE R Zone Type 2 S2000 KDL Detector Variant A B or C Variant B Dz fire detector with NO contact Da Y 3 Variant C Ds intrusion detector with NO contact D4 intrusion detector with NC contact Figure 1 Standard Wiring Diagrams Variant A is for wiring fire detectors with normally closed contacts Variant B is for wiring fire detectors with normally open contacts and Variant C is used for wiring intrusion detectors with both normally open and normally closed contacts Reo is for EOL Resistors MF 1 4W 10k 5 provided while R and R3 are additional resistances MF 1 4W 20k 5 and MF 1 4W 4 7k 5 respectively You can wire several conventional dry contact detectors into a single monitored circuit The number of the detectors to be included is defined by the requirement that resistance of a monitored circuit wired in accordance with Variants A C must match its physical conditions as shown in Table 1 see below Variants A and B provide connecting fire detectors and recognizing such conditions of a monitored circuit as Norm Fire Alarm Open Failure and Short Failure provided that
9. ries Seller 4 Pionerskaya Str Korolev 141070 Moscow Region Russia warrants its security equipment the product to be free from defects in materials and workmanship for one year from date of original purchase under normal use and service Seller s obligation is limited to repairing or replacing at its option free of charge for parts or labor any product proven to be defective in materials or workmanship under normal use and service Seller is not responsible for results where the product is used improperly where it is used for any application it is not intended for used under unacceptable environmental conditions and mishandled or stored under improperly Seller shall have no obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than the Seller In case of defect contact the security professional who installed and maintains your security equipment or the Seller for product repair This one year Limited Warranty is in lieu of all other express warranties obligations or liabilities There are no express warranties which extend beyond the face hereof Any implied warranties obligations or liabilities made by seller in connection with this product including any implied warranty of merchantability or fitness for a particular purpose or otherwise are limited in duration to a period of one year from the date of original purchase Any action for breach of any warranty includi
10. the monitored circuit is programmed in S2000 KDL configuration as the Combined Fire Alarm Loop Type 2 see below If intrusion detectors are interfaced to the polling loop of the S2000 KDL in accordance with Variant C the relevant monitored circuit detector loop should be configured as the ntrusion Alarm Loop Type 4 or Auxiliary Alarm Loop Type 6 or Entrance Alarm Loop Type 7 or Panic Alarm Loop Type 11 see below In such a case the S2000 KDL recognizes such circuit conditions as Norm and Intrusion Alarm MOUNTING Hang the S2000 AR2 on a wall by means of the woodscrews provided The drilling pattern is shown in Figure 2 monitored circuits DL1 and DL2 to the NO or NC contacts of the relevant detectors Bring EOL resistors and if necessary additional resistors into monitored circuits in accordance with the selected wiring schemes Please keep in mind that the resistance of each monitored circuit without regard to EOL resistor should NOT exceed 100 Q while leakage Figure 2 Drilling Pattern resistance should be at least 50 kQ l l Connect PL contacts of the S2000 AR1 to the relevant polling loop wires Connects i 47 l l l eT PROGRAMMING In order the S2000 AR2 operates properly within the multiplex addressable polling loop of the S2000 KDL controller the module must be assigned to a unique number from 1 to 126 within the polling loop or the loop address which is stored in the module non volatile memory The S2
Download Pdf Manuals
Related Search
Related Contents
lpe - fiche technique - ags - ballon d`extraction PK-HC08QY4 User`s Manual Voir la liste des conférences organisées par Carqueiranne User Guide - Honeywell EPSON Perfection 660 SBT-Pneumatic VAIO Computer Recovery Options Guide TELECHARGEZ ICI LA BROCHURE CX 5000 ET 6000 Copyright © All rights reserved.