1. Generalities and security Page 34 us E OXIOI IZ User manual Generalities and security 7 6 Read test Paper transport mechanism OMR read heads barcode read heads functions can be verified in the Read menu axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert D amp amp 28 Axm940 960 gt TRANSPORT AND READ 1 image 2 external 3 transport v gt 00 14 26 connect D tec auto 2400 8 N 1 7 6 1 Image mode For this test at least one OMR read head should be present In this mode functioning as well as positioning of the OMR read head can be verified An image of the document is displayed on the screen and the read level 0 to E is given for each mark In this mode the thickness sensor is always activated To carry out this test any OMR document may be used provided that it is well printed and cut as well as the following explanations refer to Axiome TMN test form with 40 or 48 tracks delivered with the machine 16 10 06 Page 35 axm960 User manual E OXIOI Test axm950 HyperT erminal Fichier Edition Affichage Appel Transfert 2 iol x Dis al 3 alal l JE Es EEE JE EBs E E E E E 1111111222 4349944644 TTA 8888888888 SAASSAASAA BCBBBBBBCB DDDDDDDDDD EEEEEEDEEE E E E E E 1112121112 4433443344 PEAT 8888888888 9999999hA9 CBBBCBBCBB DDDDDDDDDD EDEEDEDEEE E E E E E E E 2211222122 hhhhhhhhhs 7777778788 8888888888 SSASAAAAAA BBCBBBC
2. The necessary files are located in LCDaxmV12 2005 Utilities Usb 9xx Driver USB Axiome When the reader in connected to the PC with the USB cable a new device will be automaticly detected You just have to follow the procedure give by your support If a special file is requested you can find it in the Driver USB AXIOME as explain before Remark It is necessary to repeat the operation twice before the new device is correctly installed 6 2 Control switch amp LED The control switch presents 4 distinct functions with corresponding LED colouring 6 2 1 Starting in read mode Press the control switch until the LED turns green then release An auto test is carried out If it is unsuccessful the LED flashes red green If the problem persists switch to test mode see below If the auto test was successful the reader is now in read mode and is ready to be piloted by the communication software 00 E OXIOI IZ User manual Generalities and security 6 2 2 Starting in test mode Press the control switch until the LED turns red approx 2 5 secs then release The reader is now in test mode ready for various functional tests on the machine For further information regarding this mode please refer to chapter 7 Test mode page 20 6 2 3 Starting in bootstrap loader mode Presently not available option 6 2 4 Switching off Whatever mode the reader is in press the control switch until the LED turns off approx 3 secs then release
3. 6 2 5 Automatic switch off Disconnecting the USB connection if the reader in ON will automatically start the switch off of the reader 2 3 seconds after disconnection 16 10 06 Page 14 us E OXIOI IZ User manual Generalities and security 6 3 Loading a configuration file The configuration file is a text file containing information such as communication configuration response format automatic configuration according to application requirements This file will be stored in the flash memory block of the reader and will help to establish communication with the PC The configuration file must be sent to the reader in a text file format It remains stored until the next transfer of a new configuration file 6 3 1 Communication The transfer will be carried out according to the parameters defined in the last configuration file down loaded into the reader If the parameters are accepted the reader returns OK followed by lt CR gt In case of errors into the configuration file the number and the contain of the incorrect line will be returned The new parameters in particular the transmission speed will take effect only after the OK reply 6 3 2 How to proceed 1 Run the HyperTerminal communication program select FILE then PROPERTIES Configuration file download HyperT erminal iol x Fichier Edition Affichage Appel Transfert Nouvelle connexion Ouvrir Enregistrer Enregistrer sous Mise en page I
4. 7 1 2 User parameters To be used to visualise and erase data contained in the flash memory axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert D 506 Default parameters DEFAULT nothing lt type a key gt _ 01 25 36 connect D tec auto 2400 8 N 1 Erasing user parameters leaves the reader with default parameters 16 10 06 Generalities and security Page 27 axm960 User manual 7 2 Motor E OXIOI The forward backward function of the document transport motor can be verified using motor test 7 2 1 Motor forward axm960 HyperTerminal BEE Fichier Edition Affichage Appeler Transfert Oe 23 08 Axm940 960 gt DRIVER STH100 1 forward 2 stop 3 backward 00 00 18 connect D tec auto 2400 8 N 1 When the 1 key is pressed the motor runs in forward mode and the status is displayed on the screen 16 10 06 axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert Da 3 DE MOTOR FORWARD 1 forward 2 stop 3 backward 00 00 25 connect D tec auto 2400 8 N 1 Generalities and security Page 28 eo E OXIOI IZ User manual Generalities and security 7 3 Panel test The LED colour function and the control switch can be verified in front panel menu axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert PANEL 1 LED green 2 LED red 3 LED orange key state KEY OFF 00 11 15 connect D tec auto 2400
5. OFF UTOEJECT OFF A gt P A EADACK C1 lt 0D gt DATAACK SD lt 0D gt SYSERROR E SE lt OD gt SHEETCTRL ON END Remarks The default configuration file DEFAULT MAX is to be found on the cd rom delivered with the machine 16 10 06 Page 19 axago E OXIOI IZ User manual 7 Test mode Generalities and security In test mode it is possible to verify and set up configuration of various reader functionalities However a USB connection with a computer and a Hyper Terminal type communication programme or equivalent is indispensable To do this please follow the procedure below 1 Run Hyper Terminal select FILE then PROPRIETE Test axm950 HyperTerminal Iof x Fichier Edition Affichage Appel Transfert Nouvelle connexion Ouvrir Enregistrer Enregistrer sous Mise en page Imprimer Quitter Alt F4 Affiche les propri t s de la session en cours h 16 10 06 Page 20 ne E OXIOIII User manual Generalities and security 2 Select the communication port to which the reader is connected Propri t s de Test axm950 Vv UTISENE Code co pays etlindicatt ET SGGCUBE OK Am 16 10 06 Page 21 ne E OXIOII User manual Generalities and security 3 Use the default parameters Propri t s COM2 PIQUE 16 10 06 Page 22 us E OXIOI IZ User manual Generalities and security When th
6. automatic unit with a motorised entry feeding tray and two output tray for the document s ejection Its conception allows a simple handling and easy access to the documents it s also easy to maintain Its high transport speed adding to the exclusive feeding and double detection systems make it reliable and effective 1 1 1 General Technical Information e Operating temperature 10 40 C 50 104 F e Relative operating humidity 40 80 without condensation e Storage temperature 0 40 C 32 105 F e Relative storage humidity 40 80 without condensation e Power supply unit 115 230 V 50 60 Hz e Power consumption Running mode 25 W Standby 12 W OFF 6W 16 10 06 Page 4 axm960 User manual 1 1 2 Mechanical Characteristics 16 10 06 e Capacity of the input tray e Capacity of the two output tray e Feeding e Speed of document transport e Paper weight e Minimum document size e Maximum document size e Paper quality e Document alignment e Double feed detection e Tray management E OXIOII IZ 120 documents for documents of 100 g m2 120 documents each Automatic 0 8 m s 80 to 160 g m2 160 x 60 mm 6 3 x 2 3 305 x 229 mm 12 x 9 Optical reading quality non chemical Automatic Automatic thickness detection Controlled by the program Generalities and security Page 5 ome E OXIOI User manual Generalities and security 1
7. 1 3 Dimensions of the machine e Length 610 mm 24 e Width 320 mm 12 6 e Height 25 mm 27 6 e Weight 12 6 kg 27 78 Lb 1 1 4 Reading Head Each track consists of a photosensitive element framed by two LED s light emitting diode illuminating the reading zone e Head with red light For fibre pen pencil or ballpoint pen marks Printout of the polychrome document with clock marks marks for line synchronisation in black marking fields in red orange or yellow e Head with infrared light For pencil marks only Printout of the polychrome document with clock marks marks for line synchronisation in black marking fields in different colours color references in the Axiome Technical Application Note e Reading adaptation Automatic adaptation to the background colour of the document 16 10 06 Page 6 ome E OXIOIII User manual Generalities and security e Paper dust Dust dense and auto cleansing e Mark density Output on 15 independent density levels for each channel Less insensitive to mirror and fold marks e Number of tracks 48 at a spacing of 1 6 or 40 at a spacing of 1 5 Number of clock tracks 1 for 48 track head 1 for 40 track head 16 10 06 Page 7 alias E OXIOI User manual Generalities and security 2 Generality and Security The axm 960 has been designed in compliance with safety regulations applicable to terminals in an office environment This machine can be used in permanent
8. 43 connect D tec auto 2400 8 N 1 In case all the OSW are in capital letters proceed to a setup of the OSW see chapter 7 4 2 OSW setup page 32 16 10 06 Page 31 axago E OXIOI IZ User manual 7 4 2 OSW setup Generalities and security Light barriers adaptation is done through the Test mode The adaptation is not continuously made to avoid useless reader s stops The below operation can be done only during a maintenance service and by trained technicians No document or paper present in the input tray or in the transport mechanism Press the key 2 for OSW setup OSW are automatically set and keep the setting till the next switch calibration Values are displayed 00 OSW is not working or not connected 06 98 OSW is optimum 99 OSW is working but the safety margin is low e axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert D Axm940 960 gt DRIVER SEN100 1 Switchs test 2 OSW setup 3 Thickness trim OSW SETUP 21 30 25 00 lt type a key gt _ lt 03 46 33 connect D tec auto 2400 8 N 1 16 10 06 Page 32 eo E OXIOI IZ User manual Generalities and security 7 4 3 Thickness trim The below operation can be done only during a maintenance service and by trained technicians To test the thickness switch documents of around 1 10 mm in thickness should be used This is usually the case with 80g m2 paper axm960 HyperTerminal Fichier Edition Afficha
9. 8 N 1 7 3 1 LED test By pressing keys 1 2 or 3 the LED see position 3 of chapter 4 Presentation of the axm 960 page 10 turns green red or orange respectively 7 3 2 Key test The status of the reader s control switch see position 4 of chapter 4 Presentation of the axm 960 page 10 on the screen and indicates whether switch is pressed KEY ON or released KEY OFF 16 10 06 Page 29 us E OXIOI IZ User manual Generalities and security 7 4 Sensor test Optical switch functionalities and thickness detector may be verified in sensor menu axm960 HyperTerminal DER Fichier Edition Affichage Appeler Transfert D 5 08 DRIVER SEN100 1 Switchs test 2 OSW setup 3 Thickness trim 00 25 42 connect D tec auto 2400 8 N 1 7 4 1 Optical switch test The method to test the optical switch OSW is digitally The functions described further on correspond to the light switches as given below a input switch OSW 1 b separation switch OSW 2 c output switch OSW 3 f reserve switch Calling mechanism switch 16 10 06 Page 30 axago E OXIOI IZ User manual Generalities and security By closing OSW the digital status of the corresponding OSW can be obtained small letter open capital letter closed axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert D S3 28 DRIVER SEN100 1 Switchs test 2 0SH setup 3 Thickness trim OSW STATE ab C f_ lt 00 30
10. 9A9 67777787 55556665 21222232 DDDDDDDDDD CCCDDCCDDD ABBBBBBBBB 9A9AAAA9IAA 7878788787 5565666666 2222322332 DDDDDDDDDD CCCCCCDDDC BBBBBBBBBB AAAAAAAAAA 7888888888 6666666676 3323333343 DDDDDDDDDD CCCCCCDDCC BBBBBBBBBB AA9AAAAA9A 7888888888 6666676766 3333343433 DDDDDDCDDC CCCCCCCCCC BBAAABBBAA A9999AAA99 8877788877 6666666665 3322233432 ED DLE Los 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 PrP D D D D D D D D D PP SP Pe D D PP PSP Generalities and security Second part of the test sheet To interpret in the same way than first part If the results are very different from the first part an unstable paper transport can be th reason e Make sure that the document is well cut and not damaged Little differences particularly on the lines 9 and 10 are due to printer precision If in doubt use more than one test sheet Finish the test with a clean blind colour sheet with 66 clock marks no mark may be read Page 38 us E OXIOI IZ User man
11. CCC DDDDDDDDDD EEEDEEEEEE 111111 1 11111111 EEEEEEEEEE 2233333333 4444500045 8888888888 9888888888 AAAAAAAAAY CCCCCCBCCC DDDDDDDDDD EEEEEEDDED 0 1 5 form section A B side lt SPACE gt next sheet ra gt 00 05 00 connect List of commands for the Image Test 16 10 06 Key 1 to 5 Key A Key B Key SPACE Key Esc Display the different part of the form 23 lines per part D tection auto 19200 8 N 1 Display upper side of the form Display downer side of the form Call next sheet Quit ImageTest D fil Mai Num Capturer Echo Generalities and security Page 36 axm960 User manual E OXIOI tracks 2 and 48 or 40 first of the head position Interpertration of the Image test Dee ee eee Dis D D D D A value smaller than D indicate a D D D glass or marbleis ttt teen eens dirty D D D E E D D Lines 9 a
12. E OXIOII IZ axm960 Preliminary User Manual User manual 5 OXIOIII 16 10 06 Page 1 E OXIOII IZ axm960 1 General information 4 1 1 Presentation of the axm 960 4 1 1 1 General Technical Information 4 1 1 2 Mechanical Characteristics 5 1 1 3 Dimensions of the machine cceeeeeeeee 6 1 1 4 Reading H64d 448 restaure 6 2 Generality and Security 8 3 Transport and installation 9 3 1 Operating environment ceeeeeeeeeceeeeeeeeeeeeeeeneeeeeeeeeees 9 4 Presentation of the axm 960 sssasssssssnnnnnnnnnnnnnnnn 10 5 ConnectionS eincccacectccscescecndentcececeactscnceaccnceserdceccseuess 12 5 1 Reader s connection 628 annees 12 5 2 Reader s disconnection 12 6 First use of the reader 13 6 1 Installation of the USB drivers 13 6 2 Control switch amp LED nent 13 6 2 1 Starting in read mode 2 0 0 2 cc cece eeeeeeeeeeeeeeeeeeeeeee 13 16 10 06 6 2 2 Starting in test mode 14 6 2 3 Starting in bootstrap loader mode 14 6 2 4 Switching off 2225 dans een ed 14 6 2 5 Automatic switch off 14 6 3 Loading a configuration file 15 6 3 1 Communication serie NME neue 15 6 3 2 How to proceed 15 6 3 3 Default configuration values 19 Fe TO SCMOMS eee 20 ete OED ae a ee eee eee eee eee 24 7 1 1 Co
13. curity 7 1 1 Configuration Upper Lower Head This menu allows to activate and calibrate the OMR read heads and to verify the read head version and serial number e Read head version V20248 e Read head serial number NO50708 for the upper head When you start the reader for first time heads are calibrated as axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert Da 8 DE Axm940 968 gt Board Type AXM94001 Board Number 050691 1 Configure Upper Head lt 20248 gt lt N 50708 gt Calibrated 2 Configure Lower Head lt 20248 gt lt NO50240 gt Calibrated 3 View user parameters 4 Erase user parameters 00 17 37 connect D tec auto 2400 8 N 1 16 10 06 Page 25 us E OXIOI IZ User manual Generalities and security The OMR read head must be calibrated each time a change is made so as to ensure correct functioning and good reading Calibration also results in the activation of the OMR read head To carry out calibration please follow the procedure described below Open the upper lid Place a Press 1 key to calibrate upper head and 2 key for lower head When TMN is succesfully calibrated press the ENTER key to valid the calibration In case of an error the first canal having caused problems will be signalled Canal errors can be due to stains on the sheet of paper An error 0 means clock tracks An error 49 means a general defect 16 10 06 Page 26 ne E OXIOI IZ User manual
14. d Calling system mechanism Entry stop Service cable plug USB data cable plug External power supply plug E OXIOII IZ Generalities and security Page 11 pal E OXIOI IZ User manual Generalities and security 5 Connections 5 1 Reader s connection When installing the axm 960 and its peripherals the cables must be connected in the following order Connect the cable for USB data transfer to the reader s first then to the PC Connect the external power supply cables first to the reader then to an earthen wall socket Once these steps have been taken a pressure on the control switch will switch on the axm 950 and its peripherals On the axm 960 the connection plugs are located at the right side of the machine refer to chapter 4 Presentation of the axm 960 page 10 5 2 Reader s disconnection Turn OFF the reader and its peripherals Disconnect the power cable Disconnect the USB cable for data transfer If necessary disconnect the service cable 11 WARNING if the USB cable is not connected or disconnected the reader goes automatically switch off see chapter 6 2 5 Automatic switch off page 14 16 10 06 Page 12 us E OXIOI IZ User manual Generalities and security 6 First use of the reader 6 1 Installation of the USB drivers Before using the axm960 for the first time it is necessary to install the USB drivers You can find the drivers on the CD rom deliver with each AXIOME readers
15. e here below diagram Find a complete spare parts list with the tyre reference at the end of the manual 9 2 Separation belt exchange Can only be performed by trained people 16 10 06 Page 40 ox 60 E OXIONE User manual Generalities and security SHEMB 2000 M98550 4000 MSCA505009 FROI6D7000 C5x SHEM813000 3x FROI66700D M985564009 SHEMB 12009 HEM50700D HEMSOB90G FCOLO20960 M3835504660 SHEMA 2000 MSCAS05000 16 10 06 Page 41 us E OXIOI IZ User manual Generalities and security 10 Spare parts The replacement parts for the axm 960 can be ordered from AXIOME Alpha SA or from your retailer Replacement parts for the axm 960 Part Number Units per machine M985504000 Transparent transport wheel MSCA505000 Green transport wheel 3 MHEM506000 Separation tyre Dual feed wheel Separation belt 16 10 06 Page 42 axago E OXIOI IZ User manual Generalities and security 11 Contacts AXIOME Alpha SA Rue du Chasselas 1 CH 2034 Peseux Switzerland e mail info axiome ch support axiome ch website www axiome ch Tel 441 032 732 18 18 Fax 41 032 732 18 00 Printed in Switzerland by AXIOME SA 16 10 06 Page 43
16. e reader is switched to test mode red LED the following menu is automatically displayed on the PC monitor screen If the reader is already in test mode press escape on the computer keyboard to display the menu axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert Axm940 960 gt TEST release 1 00 Firmware 1 0 0 0 Setup Motor Panel Sensor Lift amp Solenoids Read 00 15 18 connect D tec auto 2400 8 N 1 Remark To go to the next menu of your choice press the corresponding key To return to the previous menu press the ESC button on your keyboard 16 10 06 Page 23 neo E OXIOIII User manual 7 1 Setup Generalities and security This list gives the reader configuration indicating which elements are present or absent The list only provides status of peripherals and does not allow correction of errors On the main menu the following indications are found e CPU Board Type AXM940xxx e CPU Board Serial Number 050691 in this exemple axm960 HyperTerminal Fichier Edition Affichage Appeler Transfert Da 5 DE Axm940 968 gt Board Type AXM94001 Board Number 050691 1 Configure Upper Head lt 20248 gt lt N 50708 gt Calibrated 2 Configure Lower Head lt 20248 gt lt NO 50240 gt Calibrated 3 View user parameters 4 Erase user parameters 00 18 00 connect D tec auto 2400 8 N 1 16 10 06 Page 24 eo E OXIOI IZ User manual Generalities and se
17. ge Appeler Transfert De 53 DE DRIVER SEN100 1 Switchs test 2 OSW setup 3 Thickness trim THICKNESS SENSOR TRIM Present trim value 041 Please place a 0 1mm sheet 8 g m2 and press lt enter gt key lt 01 20 06 connect D tec auto 2400 8 N 1 The displayed value must be situated between 30 and 50 Doing new calibration request a brand new document without fold When calibration is passed differents values are given Keymean Average thickness value on document Peak Maximal thickness value Trim New trim value In this results the Peak value must be less than 15 upper the Keymean value If results are not answering this needs contact Axiome Alpha SA 16 10 06 Page 33 amo E OXIOIII User manual 7 5 Lift and Solenoid test 7 5 1 Lift UP DOWN Check the functionality of the input lift Press the key 1 and the lift moves up Press the key 2 and the lift moves down 7 5 2 Calling solenoid ON OFF The electro magnet of the document calling system can be verified in this menu By pressing key 3 the solenoid is fed and should moves down By pressing key 4 the solenoid is fed and should moves up 7 5 3 Eject solenoid ON OFF The electro magnet of the document ejection system can be verified in this menu By pressing key 5 the solenoid is fed and should moves down with the ejection mechanism By pressing key 6 the solenoid is fed and should moves up with the ejection mechanism 16 10 06
18. mprimer Quitter n Alfiche les propri t s de la session en cours ne E OXIOIII User manual Generalities and security 2 Select the communication port to which the reader is connected Propri t s de Test axm950 Diriger vers Com2 UTISENE Code co pays et lindicat E Heppeler si occupe OK Am 16 10 06 Page 16 us E OXIOI IZ User manual Generalities and security 3 Select the suggestes default communication There is no importance of the parameters because of the USB communication Propri t s COM2 Appiiguen 16 10 06 Page 17 axago E OXIOI IZ User manual Generalities and security 4 Select TRANSFER then SEND A TEXT FILE amp Configuration file download HyperT erminal Ioj x Fichier Edition Affichage Appel Transfert O l FE Envoyer un fichier S 5 Recevoir un fichier Capturer le texte Envoyer un fichier texte Capturer vers l imprimante v 4 b Envoie un fichier texte au syst me distant 5 Select the configuration file you want to download to the reader If an error is contained in the configuration file the reader will answer with the number and the contain of the incorrect line followed by lt CR gt 16 10 06 Page 18 mnoe0 E OXIOIII User manual Generalities and security 6 3 3 Default configuration values The configuration file set by default into the reader is DEFAULT XDATAMODE N UTOCALL
19. n 10 Dyslexia 12111111 111l1 e eee eee eee 11111 1111122321 The lower and more 27 su ses mme esse mes T uniform the value is the better it is the maximum eiei Eii EDE value admitted is 3 os One 2 alone inside of 12222222 2222222232 2221212221 2222233333 3332233322 points is disquieting 44445545 4555545554 4455444444 4555555555 5555555654 78878888 8888888888 8888888888 8888888988 8888898988 88989999 8999999999 9998899899 8999999999 9989999998 Lines 8 12 21 23 A9AAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAABAAAA Must be empty CBBCCCBC CCCCCCCCCC CCCCCCCCCC CCCCCCCCCC CCCCCCCCCB No marks CCDCCDCD DDDDDDDDDD DDDDDDDDDD DDDDDDDDDD DDCDDDDDDD DDEDDDEE 78888888 899999A99A 99AAAA9AA9 99999A9999 99999A9A99 Generalities and security Lines 2 3 4 values D or E 001 A BE Shift the 002 A read head to 003 A the left 004 A side 005 A 006 A Lines 6 and 7 values E 007 A 008 A 009 A 010 A 011 A 012 A Lines 13 to 20 Sensivity 013 A Increasing from 2 to E 014 A A er On the same line variation 015 A maximum 3 levels 016 A O17 A 018 A RE Line 22 Skew 020 A Indicates the bias and is very sensitive Estimate Qana the generally tendency 022 A A difference between 4 023 A and 5 levels is acceptable Page 37 axm960 User manual Remarks 16 10 06 E OXIOII IZ CCDDDDDD CCCCCCCC AAAABABB 99999
20. nfiguration Upper Lower Head ee 25 7 1 2 User parameters ccccceeeeeeeseeeeneeeeeeeeeeeeees 27 72 NOIR ed adrien ed re 28 7 2 1 Motor TORWANG sense 28 1 3 PAV MS SU ES nee din nt 29 7 3 1 LED WSS Ba ccieccnntcinrelemcsteccenedemadenetemsceoaeanadereranaiebec 29 102 OY IOS sci ad eee one one oo 29 14 SENSO OS Ru Min ue 30 7 4 1 Optical switch test 30 7 4 2 OSW setup 00 2 cc eeeeececeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 32 User Manual E OXIOII IZ axm960 7 4 3 Thickness Mimizan au us Ana 33 7 5 Lift ANG Solenoid test 23e nee 34 7 5 1 DEUPIDONN ss mraammauarmdnoaonneonts 34 7 5 2 Calling solenoid ON OFF ssssssssseeeesesseseennnneeene 34 7 5 3 Eject solenoid ON OFF 34 7 6 Read TES ee 35 7 6 1 IMMO sennnens ne 35 7 6 2 External MO dans anne 39 7 6 3 Transport mode nement 39 8 M inienanee ssei ennemi 39 8 1 Regularly maintenance eeceeeeeeeeeeeeeeeeeeeeeeeteeeeeeees 39 8 2 SENICE ee een do ed 40 9 Parts exchanges and settings cccceseeeeeeeees 40 9 1 Transport tyres exchange c ceeeceeeeeeeeeeeeeeeeeeeeeeeees 40 9 2 Separation belt exchange cccceeeeeeeeeeeeeeeeeeeeeeees 40 10 Spare DANS nes eee 42 11 SOA a a nant 43 16 10 06 User Manual Page 3 E OXIONIE Preliminary User Manual 1 General information 1 1 Presentation of the axm 960 The optical mark reader axm 960 is an
21. operation at office temperatures The following guidelines must be applied when installing and manipulating the reader e The reader is equipped with a power cable which must be connected to an earthen wall socket e When installing the machine make sure the wall socket for the power supply is always within the user s reach e Do not connect or disconnect the cables during a thunderstorm 16 10 06 Page 8 axago E OXIOIII User manual Generalities and security 3 Transport and installation 3 1 Operating environment The suitability of the operating environment for the axm 960 is an essential factor for its proper functioning Issues that must be taken into account are as follows The reader must be placed on a stable flat and horizontal support The reader must be shielded from all heat sources such as direct sunlight heaters spot lights and other high heat lights The axm 960 must also be protected from vibrations and humidity 40 to 80 relative humidity with no condensation Operating temperature range 10 to 40 50 to 1 04 F Storage temperature range 0 to 40 32 to 104 F Never operate the axm 960 in atmospheric conditions contaminated by dust or oil products in gaseous state 16 10 06 Page 9 ened E OXIOI IZ Page 10 axm960 User manual 1 2 3 4 5 6 7 8 9 10 16 10 06 Primary output tray Secondary output tray Panel Led Control switch Reading head li
22. ual Generalities and security 7 6 2 External mode Presently not available option 7 6 3 Transport mode With the transport test the transport function can be verified by ejecting 1 document out of 3 into the secondary ouput tray In this mode all read heads are disabled but the thickness detector remains enabled 8 Maintenance 8 1 Regularly maintenance The regurlaly maintenance can be performed by normal user without any technical training Cleaning the reading head s glasses duster with alcohol or soaped water Cleaning the separation wheel and separation belt dry duster or brush Cleaning the light barriers dry duster or a brush Control the paper transport duster or a brush 16 10 06 Page 39 us E OXIOI IZ User manual Generalities and security 8 2 Service Service can only be performed by trained people with Axiome s agreement Regularly maintenance Control the tyre s wear Exchange if necessary Control the mechanism with the help of the test software L B double sheet detector lift output solenoid motors display Control the separation tyre and separation belt If necessary change them Needs new adjustment Paper transport with a full batch 9 Parts exchanges and settings 9 1 Transport tyres exchange For the transport tyres open the upper lid to reach all the tyres Removed the wear tyres AN For transport quality reasons all tyres are not similar respect th