Home
BED SCALE 7711 - Soehnle Medical
Contents
1. C key cursor up l EE Deletes the cursor left ENTER key ast numeral confirmation key or character TARE key TEE cursor down ON OFF key cursor right ZEROING key SPECIAL CHARACTER key WWW Soehnle medical nl Alphanumeric input It is possible to make alphanumeric inputs with the combined numeric and alphabetic character keypad Types of input box e Display fields read only e Display writing fields with numeric input option e Display writing fields with alphanumeric input option Input procedure Numeric fields Type in the numerals o to 9 directly into the KEYPAD Input is right flush A cursor flashes under the last digit entered The C key clears the numeral highlighted by the cursor The ZEROING key aborts the input without saving the new input values Existing values are retained The Enter key saves the value typed in and returns to the application pro gram The setpoint whether it is a dot comma or no decimal separator is defined in Setting mode Setting mode Terminal Display Decimal sepa rator see p 14 Only the default number of characters can be typed into an input box Any other inputs are neither displayed nor accepted Alphanumeric fields The numeric keys are also as signed by multiple programming to alphanumeric characters upper case only and characters For example the o zero key is also a and blank character The SPE
2. Hold mode p 20 Fixed tare value p 17 General Clear fixed tare value p 19 Program settings Auto standby time Plausibility check sensor p 23 Error 12 Provisional tare p 19 Weighing taring Fkey p22 Dialysis function p 19 Hold mode p 20 Second unit p 14 LM Version p 14 BMI function p 20 Display p 14 Keypad p 14 Calibrated counter status Date Time p 15 approvable Organisation data p 15 Filter setting User password p 15 Zero tracking Reset terminal p 15 Zero range at power on Second unit Serial number MS Software version MS Data Processing Data transfer fixed values p 18 Application Alibi memor mi y tpa Baud rate Interface 1 p 21 gt Print template p 21 gt printout request 1 0 port settings Printout when W TzO Barcode Decimal separator Special thousands separator Service password protected Ee Consec no print key Factory setting Only for service personnel authorised by Soehnle Professional x WWwW Soehnle medical nl Calling up Setting mode Switch the appliance on After the power on routine the appliance starts the last activated application program automatically To call up Setting mode first lt press ENTER and then the F key simultaneously You are now in the Setting mode selection menu F Inputs in Setting mode In most cases you can select from several different settings available With editable values you
3. 6 3 V 6 3 V 3 0080025005C70 OK 4 0080025005ADC OK Charge run time A battery charge is sufficient for approx 12 hrs con tinuous duty When the scale is switched off for most of the time 9096 OFF the batteries may remain in the weighing devices for up to 125 hours before they require a recharge Caution Even when the digital indicator is switched off the Bluetooth link is activated at regular inter vals For this reason the batteries will discharge in this state and must be recharged at the latest after 125 hours Recommendation Always remove the batteries from the weighing de vices after you switch off the digital indicator and place them in the battery box of in the charger This makes sure that the scale works reliably the next time it is switched on If the bed scale remains for long period of time without use remove the batteries from the weigh ing devices to prevent deep discharge The scope of supply comprises eight batteries WWW Soehnle medical nl 9 ENGLISH BED SCALE 7711 3 INPUT AND CONTROL Keypad for input and control KEYPAD To enter nume rical values or alphabetic ORG key Calls up INFO key e g electro characters alphanumeric Organisation Data nic nameplate contai keypad ning reference data o zero key lt _ lt Press several times to display PROFESSIONAL E y plus minus INFO m and the blank eS character F key function key
4. Displaying the value in the tare memory To display the tare memory press the INFO key and then the TARE key Press the ZEROING key to exit the display Changing the tare value manually later Display the tare value by pressing the INFO key and then the TARE key Enter the new value into the KEYPAD Press the ZEROING key to abort the input The existing value is retained or the new tare value is saved by pressing the TARE key Confirm by pres sing ENTER and return to the application program WWW Soehnle medical nl Error message when taring Error 06 Taring not possible Possible causes e Scale empty Scale in overload or underload e Manual tare input with tare value above maximum load Displaying the tare memory To display the tare memory press the INFO key and then the TARE key Press the ZEROING key to end the display BMI function The Body Mass Index BMI is used to assess whe ther a person has a normal weight or is overweight The BMI is calculated according to the following formula body weight kg BMI body height m x body height m The unit for the BMI is therefore kg m BMI classification separated according to gender Cassificaion underweight Normal weight Overweight 25 30 24 30 Adiposity 30 40 30 40 Severe adiposity WWW Soehnle medical nl Setting and using the operating mode Setting in Setting mode Setting mode gt Pro gram Settings gt Weighing Taring gt F key gt BM
5. and icons p 27 Calling up Setting mode p 15 2 WwWwW Soehnle medical nl 1 General information Thank you for choosing this Soehnle Professional pro duct All the features of this product were designed to the state of the art and are optimised for simple and straightforward use If you have any queries or exper ience any problems with your appliance not addressed in the operating manual please contact your Soehnle Professional service partner or visit us on the web at www soehnle professional com Intended use The appliance is designed for weighing people who are lying down The appliance may only be used for this purpose Any other use is prohibited Messages about errors or defects that could endanger the patient or operator and errors that could lead to corruption of the test results must be sent in writing to the manu facturer s medical product adviser see address be low These operating instructions as well as the operating instructions for the 3020 Digital Indicator are component parts of the appliance They must be kept near the appliance Compliance with these operating instructions is mandatory in order to en sure compliance with the intended use and correct operation of the appliance If the appliance fails to function correctly the appliance may be damaged It is essential that the appliance is then taken to an authorised Soehnle Professional service centre Only genuine spare parts may be used if an authorised servic
6. by soiling on the scale The following character appears in the icon bar when the dis play indicates zero o Zero range approvable and non approved 196 to 396 of the weighing range If zeroing is not possible the error message Value above zero range limit or Value below zero range limit appears for two seconds in the display 0 x10 times 10 display Shows the weight value with u an additional decimal place at 20 ten times the resolution Switch to the x10 display by pressing ENTER and then the ZEROING key simultaneously According to the calibration law the x10 function may only be activated on ap provable scales for a short period of time For this reason it s programmed so that the function is switched off automatically after 5 seconds The message x10 appears in the icon bar as long as the 10 time higher display is selected When the app liance is switched off the function is deactivated WWW Soehnle medical nl Weighing and taring Display view Weighing with measured tare Determine and tare a bed weight without patient Position the empty bed including bedding on the scale Press the TARE key The tare value is saved and the weight display goes to zero Now the pati ent can be laid on the bed The weight is displayed with the message Net Displaying the value in the tare memory Press the INFO key to display the tare memory and then the TARE key Press the ZEROING key to termi
7. computer may be connected to the serial data port if they conform to European Standard EN 60601 1 or a suitable dis connecting device is connected in series Applicator The scale does not have an applicator No part is in tended for direct contact with the patient Leakage currents were measured on the weighing devices in compliance with classification of Type B applicators Operating concept The appliance is operated by means of the keypad The keys are assigned with different functions de pending on the various modes Maintenance and service The measuring inspection test was performed during the initial calibration process in production Further regular measuring inspection tests recalibration must be carried out by the calibration authorities respon sible in compliance with national regulations Repairs may only be carried out by a centre authorised by Soehnle Professional using genuine spare parts The medicine device is equipped with a non de tachable power line The power line may not be ex changed by maintenance personal Cleaning Before cleaning disconnect the appliance from the mains by removing the power plug from the wall socket Only clean the appliance using a moist cloth On no account may water be allowed to enter into the appliance Disinfectant may only be applied to the membrane keyboard for the display It is prohi bited to spray the appliance and the power plug The following disinfectants are permitted
8. numeral CE mark of conformity with year of affixing and simul taneous commencement of validity of calibration Precision class No of EU approval Manufacturer s product number E g 0102 Official Code of Office Quoted this body performed the initial calibration process 27 ENGLISH BED SCALE 7711 Load Cell SN H2509xx Typ SEB46B 300 C3 MR CC 6L Soehnle Professional GmbH amp Co KG PROFESSIONAL c Typ 7711 SN 771110070001 BT 008025005BBF IP X2 6V 80 mA Soehnle Professional GmbH amp Co KG 28 SN TYP BT IPX2 6V DC 80mA Symbol for EU calibration The calibrated counter status indicates how often the scale was calibrated The stored counter status must match the calibrated counter status on the inserted label secured by adhesive label Serial number of weighing machine Product number der Lastaufnehmer Bluetooth Address Protection Class Power Supply Power Input Attend to user manual ISO 7010 Equipment for not ionized radiation IEC 60417 Functional earth IEC 60417 WWW Soehnle medical nl
9. pressing the C key e The gap in the consecutive number scheme is closed The following fixed tare value memories are given a number reduced by 1 CAUTION Under Setting mode gt Program Set tings gt General gt Delete fixed tare values all fixed values are cleared from the memory Provisional tare dialysis function Setting and using the operating mode Setting in Setting mode Setting mode gt Program Settings gt Weig hing Taring gt F key gt Dialysis function e Press ENTER and the F key simultaneously to access Setting mode e The arrow points to Program Settings Press ENTER to confirm e Press TARE to browse down to Weighing Ta ring and press ENTER to confirm e Confirm the message F key by pressing ENTER e Press TARE down or the F key up to browse to Dialysis function and press ENTER to confirm There is an acoustic acknowledgement e Exit Setting mode by pressing the ORG key The gross value is displayed Using the dialysis function e Press the F key with a load on the scale Mes sage Place tare Place the additional tare on the scale Confirm by pressing TARE The addi tional tare is accepted into the tare memory and the net value remains unchanged e Repeat this procedure for other additional tares The weight is displayed with the message Net When the scale is clipped off the tare weight is displayed with a negative sign Clear the tare by pressing the ZEROING key
10. to be con nected e Press ENTER to confirm Connection options factory setting none 2795 11 Soehnle Professional printer 2795 12 Soehnle Professional printer Data Processing PC Barcode barcode reader Large format display S302 monitor Info about printer Soehnle Professional printers are stored as standard However you can also set up other printers using the 3020 3030 Service Software Other parameters baud rate data bits parity and XON XOFF can be assigned as specified in the printer manual Please contact service personnel authorised by Soehnle Professional The parameters set at the factory are configured for Soehnle Professional printers WWW Soehnle medical nl Default print templates factory setting The print command keys can be assigned using the print templates in the service software In the fac tory setting the print template below is already stored and assigned In other words it can be prin ted out This default print template is an example showing what parameters are available Date Time Scale no Gross Tare Print command conditions The print templates are assigned to print command conditions using the service software The following conditions can be assigned to print templates e Print key ENTER e Automatic print data record once immediately e Automatic print data record once after weight change at standstill e Automatic print data record after weight change at stan
11. CIAL CHARACTER key is also avail able After pressing a numeric key twice within one se cond this activates a rolling function to access a character assigned to this key If you do not press the key a second time within one second the cha WWW Soehnle medical nl racter pressed is accepted and the cursor moves on to the next position Numerical inputs can be made in direct succession without any waiting period as long as the same number key is not pressed several times in successi on A cursor flashes under the last item entered Press the F key and the TARE key to move the cursor to the left or right The C key clears the last character on the left of the cursor or the character with the cursor flashing underneath it The ZEROING key aborts the input without saving the new input values Existing values are retained The ENTER key saves the value typed in and returns to the application program Only the default number of characters can be typed into an input box Any further input overwrites the last character ENGLISH BED SCALE 7711 Indicator display Icons characters The display shows a number of different views de Icons in the icon bar pending on the situation It is divided into display panes Alibi memory capacity 10096 Additional display Icon bar Alibi memory capacity 8096 Alibi memory capacity empt Display panel a d Keylock Additional display It displays BMI Gross Net etc If required it can be H
12. FOR MEASURABLE SUCCESS PROFESSIONAL BED SCALE 7711 OPERATING MANUAL WWwW Soehnle medical nl ENGLISH BED SCALE 7711 CONTENTS 1 General information P3 Inputs in Setting mode p15 Intended use D3 Settings in Setting mode p15 CE sign D3 Settings in Program Settings menu D 15 Classification p3 Settings in Terminal menu p 15 Safety instructions p 4 Use of additional devices p 4 Functions pg Applicator DG Power on zeroing p17 Operating concept DG Manual zeroing pi Maintenance and service p 4 x10 times 10 display p17 Cleaning DG Weighing and taring p17 Disposal DG Weighing with measured tare p17 Note p5 Weighing with manually entered tare p 18 Warranty liability p5 Weighing with stored tare values p 18 Provisional tare dialysis function p 20 2 Putting into operation p7 Error messages when taring p 21 Installing the scale elements P7 Displaying the tare memory p21 Power on D7 BMI function p 21 Radio link p8 Hold function p21 Power on Power off p8 Print p 22 Charging the batteries p8 Programming the F key p 23 3 Input and control p 10 Error messages p 24 Keypad for input and control p 10 Alphanumeric input pii Technical information p 26 Indicator display p12 Technical data p 26 Icons characters p i2 Other technical data p 26 Instructions for installing the scale p 26 4 Setting mode p 13 Electronic nameplate Keypad in Setting mode p 13 and calibration counter p 27 Overview of menu navigation p 14 Explanation of labels
13. I function e Press ENTER and the F key simultaneously to access Setting mode The arrow points to Program Settings Press ENTER to confirm e Press the TARE key to browse down to Weig hing Taring and press ENTER to confirm e Confirm the message F key by pressing ENTER e The arrow points to the last function activated e Press the TARE key to browse to BMI function and press ENTER to accept A beep tone confirms acceptance e Exit Setting mode by pressing the ORG key The weight value is displayed Using the BMI function e Press the F key The following message appears Enter body height Enter your body height in metres e Confirm by pressing ENTER Now parallel to the person s weight the BMI value is displayed in the additional display e The BMI display can be switched off by pressing the F key again Hold function Setting in Setting mode Setting mode gt Program Settings gt General gt Hold mode The Hold function Hold mode freezes the measu red value in the display dependent on the selected setting The following settings are possible ENGLISH BED SCALE 7711 not active Hold mode is off Still Key Value freezes Press the ON OFF to cancel Hold mode Still Empty Value freezes Clip off the scale to cancel Hold mode Max Key Max value freezes at standstill Press the ON OFF key to cancel Hold mode Max Empty Max value freezes at standstill Clip off the scale to cancel Hold m
14. M Multirange Multidivision 1 switched on with the F key according to the program settings Multirange Multidivision 2 Icon bar Multirange Multidivision 3 Shows information about the status of the active measuring point Resolution x10 10 times Display panel Mi Zero Shows weight value and unit characters Hold function active Unit character Symbol for standstill After placing a load on the scale bed patient etc the scale requires time to finish oscillating Until it comes to a standstill the unit character kg Ib re mains blank The unit character only appears when the scale reaches standstill and a stable value is obtained clip off WWwW Soehnle medical nl 4 SETTING MODE Keypad in Setting mode ORG key Exits the Setting mode PROFESSIONAL INFO Max Min e Setting mode b Program settings cales F key Moves the marking arrow up the list or moves the cursor to the left T key TARE key Moves the marking arrow down the list or moves the PRINT ENTER key Calls up the marked menu option or saves t an input or change cursor to the right i ZEROING key Returns to the next higher level back without saving the change WWW Soehnle medical nl KEYPAD key Clears the last numeral character ON OFF key ENGLISH BED SCALE 7711 Overview of menu navigation The following setting options are available
15. can type in values into the numerical or alphanumeric keypad Settings in Setting mode With the parameters in Setting mode you can adapt the weighing and taring application program to your specific requirements Settings in Program Settings menu In the Program Settings Settings menu you can adapt the Application program of your scale to your specific requirements the bed scale mainly uses Weighing and taring www soehnle medical nl Settings in Terminal menu In Terminal Setting mode you will find the follow ing request and setting options Version AZG software version Display only AZG applications software Display only AZG serial number Display only CPU board serial number Display only Display Backlight Sets the luminosity enter as a percentage into the numerical keypad 0 dark 100 fully luminosity factory setting 80 Contrast setting enter as a percentage into the nu merical keypad 1 is low est contrast 100 is full contrast factory setting 50 Deutsch English Fran ois Comma point or none Factory setting comma Contrast Language Decimal separator Second unit g t Ib mg oz additional field in display Keypad Keylock Individual several or all keys on the keypad can be locked Press the key to be locked to change the status of the key from unlocked to locked and vice versa ENGLISH BED SCALE 7711 Keytone Validation tone Date time Time Date Date fo
16. dstill e Automatic print data record after weight change at standstill above the empty message e Automatic print data record after weight change at standstill above the empty message if the active empty message was previously active e Continuous transmission e ENTER Accept key when ORG A is entered e ENTER Accept key when ORG B is entered e ENTER Accept key when ORG C is entered www soehnle medical nl e ENTER Accept key when ORG D is entered e Key combination INFO F and ENTER dependent on settings ENTER Accept key for manual input e Print alibi memory Programming the F key The F key is programmable to call up various func tions It assumes different functions depending on how it is assigned The current function is selected in Setting mode Access Setting mode by first pressing ENTER and then the F key simultaneously In Setting mode you will find the F key program ming options under Program Settings gt Weighing Taring F key Select the required function by pressing the F or the TARE key and confirm by pressing ENTER The following functions are available Provisional tare Dialysis function Hold mode Second unit BMI function Exit Setting mode by pressing the ORG key 23 ENGLISH BED SCALE 7711 6 05 06 07 08 09 10 11 12 13 15 16 18 20 Error messages Error numbers gt Cause Remedy Info Zeroing not possible gt Deviation from zero point too large Tarin
17. e charger itself LED status indicator on charger for each charge compartment LED lights up orange battery still charging LED lights up green battery charged trickle charge LED status indicator on weighing device Digital indicator is switched on radio link active LED lights up green battery charged First exit the editing section before switching the scale S LED flashes green mainly on off for short off The weighing devices have no on off switch They are only switched off when the batteries are removed OFF display When the scale is switched off but remains connected to the power supply the indicator display shows OFF in accordance with the Medical Equipment Directive periods battery still has sufficient capacity for normal operation LED flashes green normally off only on for short period battery almost empty battery must be recharged Digital indicator is off or in standby mode s LED lights up green for approx 2 mins and then starts to indicate standby mode by flashing mainly off The charging time for empty batteries is approx 4 hours Batteries should be charged and exchanged in sets The batteries may remain for any length of time in the charger when it is on 8 WWVW Soehnle medical nl Display of link state Press Info key 1 The following appears in the indicator display Weighing device State 1 0080025005BB7 OK 2 0080025005CoD Error Battery voltage 6 3 V
18. e station carries out repairs These genuine parts are described in the service documentation Spare Parts List 470 014 037 Scale 470 630 273 Digital Indicator 470 014 038 Weighing Device including Order Number Soehnle Professional will only assume responsibility for the safety of the appliance if these instructions are observed and the appliance is operated in com pliance with the operating instructions The appliance is a medical device and may only be used by persons who are capable of handling it correctly as a result of their training Before using the appliance the user must ensure that the appliance is functional and in proper working order The operator must know how to operate the appliance The appliance is not intended for use in medical rooms subject to explo sion hazards Explosion hazard areas may occur if flammable anaesthetics skin cleansing agents and skin disinfectants are used CE sign The product carries the CE sign in accordance with the following directives e 89 336 EEC Electromagnetic Compatibility e 73 23 EEC Low Voltage Directive 90 384 EEC Nonautomatic Weighing Instruments e 93 42 EEC Medical Cc 5 Products Class Typ 7711 with measurement pecans ROO function Soehnle Professional GmbH amp Co KG d von Ardenne Allee 12 71522 Backnang Germany Classification e Class medical product with measuring function c Electrical Safety Class Il with double isolated function gr
19. g no possible gt Empty scale scale underloaded or overloaded manual tare input with tare value above max load Print not permitted No mass unit switchover Print signal buffer full Load cell signal overflow No measuring point signal Check sensor position gt Incorrect lever setting for at least one weighing device or no weigh on at least one weighing device plausibility check active Converter failure Measuring point write protected No measuring point detected Measuring point not zeroed Print format empty 24 23 24 25 26 30 33 34 35 36 37 40 4G Print error Print template memory corrupt No print template s Printer update cancelled Alibi memory full Alibi memory contents corrupt Alibi memory empty No or defective alibi memory Cannot write alibi Alibi memory unreadable General data format error Input value too small 42 Input value too big 44 Power off not allowed 50 Value below zero range limit gt Zeroing not possible because measured value is outside the set zero range limit WWwW Soehnle medical nl 51 Value above zero range limit gt Zeroing not possible because measured value is outside the set zero range limit 52 Overload gt Measured value above weighing range 53 Underload Measured value below o zero 55 Place weight on scale Scale empty or no clip off setting made according to set clip off factor 75 Replace backup battery 76 C
20. harge batteries 80 Abort external command 81 Timeout external command 82 Number exists already The identification assigned to a fixed value exists already 90 Fixed value memory occupied full A total of 100 memory locations are available valid for all programs 98 Wrong barcode WWW Soehnle medical nl 25 ENGLISH BED SCALE 7711 7 Technical information Technical data Weighing range Division Min max load Max bed weight 250 kg Approval number Do7 09 034 PTB 0102 Ambient operating temperature 10 C to 40 C rapid temperature changes e g in the event of cold drau ghts may impair the test result 40 C to 70 C 2096 8596 relative humidity non condensing Digital indicator power supply power adapter mains voltage 100 240 V 50 60 Hz Weighing device power supply From 6 V lead gel battery battery capacity 1200 mA continuous duty approx 12 hours Transportation conditions The appliance may only be transported in its original packaging comply with storage temperature avoid vibrations and shocks 19 keys function key freely programmable Organisation data memory 4 memories alphanumeric input via the numerical keypad see nameplate see nameplate see nameplate Storage temperature Humidity Membrane keyboard Display Dot matrix 240 x 64 pixels dimmable backlighting Fixed value memory for to tal of 100 fixed values va lid for all programs power failsafe alibi memory fo
21. hing devices are designed to re ceive wheel diameters of 130 160 mm Small diam eters are optional Power on Power off Switch on or off the digital indicator by pressing the On off switch The message SOEHNLE PROFESSIONAL appears in the indicator display together with a search icon until the radio link is set up to the weighing devices This normally takes 20 to 60 seconds When the radio link to the weighing devices Is set up the indicator display shows the current gross weight value www soehnle medical nl 7 ENGLISH BED SCALE 7711 Radio link The Bluetooth radio link operates over a max radius of 5m if there is no partition wall between the weig hing devices and the digital indicator After short inter ruptions e g to replace a battery or caused by the loss of battery contact due to shocks the link is restored automatically within a few seconds Power off If the sensors are overloaded or you have started a menu the scale switches off after you press the On Off button for 5 seconds It is not possible to switch off the sca le as long as it is waiting for an input in the editing section of Setting mode Charging the batteries Open the cover of the battery charger The charger has four compartments to recharge the four batteries simultane ously The four LEDs indicate the charge state for each battery The fifth LED on the charger is the mains power indicator for th
22. ing up the list of fixed tare value memories for taring The tare value from the fixed tare value memory can be activated with the scale unloaded i e be fore the weighing operation or with the scale loa ded during a weighing operation The display pane shows a weight value 2 0 000 kg First press ENTER and then the TARE key simul taneously The fixed tare value memory last used appears in the display Press the F or TARE key to browse to the required fixed tare value memory or type in the memory location number and confirm by pressing ENTER Press ENTER to activate the fixed tare value The display shows the gross value minus the tare value net Further tare values from the memory are activated by repeating the procedure described above Clearing an existing fixed value Call up the input menu Setting mode gt Program Settings gt General gt Fixed tare values Press ENTER and the F key simultaneously to access Setting mode The arrow points to Program Settings Press ENTER to confirm ENGLISH BED SCALE 7711 e Confirm the message General by pressing ENTER e Press the TARE key to browse to Fixed tare va lues and accept by pressing ENTER Clearing a tare value e The last selected fixed tare value memory is displayed Press the F or TARE key to browse the required fixed tare value memory or enter the memory location number and confirm by pressing ENTER e Clear the displayed fixed tare value memory by
23. methy lated spirits Isopropanol 296 Kohrsolin 196 aqueous Sokrena solution 596 Sagrotan or 596 Gigasept 4 WWW Soehnle medical nl Disposal According to the present state of the art the appliance contains no special environ mentally harmful substances This product MM is not to be treated as regular household waste but should be handed in to an electrical elec tronic equipment recycling centre You can obtain further details from your local council your munici pal waste disposal company or the firm from which you purchased the product Battery disposal Do not dispose of batteries in the household rubbish As consumer you are obliged by law to return waste batteries You can hand in your old batteries as hazardous waste to the public col lection centres in your municipality or return them to the firm where you purchased them You will find these labels on batteries containing hazardous sub stances Pb battery contains lead Cd battery contains cadmium Hg battery contains mercury Lead gel batteries are used to power the weighing devices They must also be disposed of as hazard ous waste and returned to the dealer when pur chasing new batteries Note Interference suppression of the unit corresponds to the valid EU Directive 89 336 EEC The display value may be influenced by extreme electrostatic and electro magnetic interference e g operation of a radio unit or a mobile phone in the immediate vicinity of the
24. nate the display Changing the tare value manually later Display the tare value by pressing the INFO key and then the TARE key Enter the new value into the KEYPAD The ZEROING key cancels the input Exi sting values are retained or new tare values are sa ved by pressing the TARE key Confirm by pressing ENTER and return to the application program ENGLISH BED SCALE 7711 Weighing with manually entered tare If the patient is already on the bed and the bed weight is known then this can be tared by manual input Enter the known bed weight tare weight using the KEYPAD The input appears in the display with the current weight unit Press the TARE key The nput is transferred into the tare memory and the tare weight is deducted from the weight display The patient s weight measured in this way is dis played with the message Net Showing the value in the tare memory Display the tare memory by pressing the INFO key then press the Tare key Press the ZEROING key to end the display Changing the tare value manually later Show the tare value by pressing the INFO key and then the TARE key Enter the new value into the KEYPAD Press the ZEROING key to cancel the input The existing value is retained or the new tare value is saved by pressing the TARE key Confirm by pres sing ENTER and return to the application program Weighing with stored tare values Known bed weights can be stored as the tare value in a power failsafe memo
25. ode Delay Key Max value freezes movement Press the ON OFF key to cancel Hold mode Delay Empty Max value freezes movement Clip off the scale to cancel Hold mode Print The 3020 Digital Indicator can be connected to a printer via the serial port to print out scale chits Up to a max of 15 print templates can be stored You can obtain a service software from Soehnle Profes sional service centres for the 3020 3030 to design print templates with customised contents The parameters listed in the standard print templates can be used to design user defined print templates In addition organisation data identifiers and user defined parameters such as company names can be included Please contact your Soehnle Professional service partner about your print template requirements Start the print routine either by pressing ENTER or by pressing another print command e g the F key 22 Configuring the printer port Setting in Setting mode Setting mode gt Data Processing gt Interface 1 gt Application gt 2795 11 e Press ENTER and the F key simultaneously to access Setting mode e The arrow points to Program Settings Press the TARE key to browse to Data Processing Press ENTER e The arrow points to Data transfer Press the TARE key to browse to Interface 1 Press ENTER e The arrow points to Application Press ENTER e The arrow points to 2795 11 Press the TARE key or the F key to select the printer
26. ound No applicator e Waterproof to IEC529 IPX2 WWW Soehnle medical nl 3 ENGLISH BED SCALE 7711 Safety instructions Before putting the appliance into use please read with care the information given in the Operating Instructions They contain important in structions for installation intended use and mainte nance of the appliance The manufacturer shall not be liable if the following instructions are not observed In case the electrical components are used under increased safety requirements compliance with the appropriate regulations is compulsory Never perform work on the appliance while the power is switched on Improper installation will render the warranty null and void Ensure the voltage marked on the power supply unit matches your mains power supply The device is designed for use within buildings Observe the permissible ambient temperatures for use Tech nical Information The device meets the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the applicable stand ards If you have any problems contact your local Soehnle Professional service partner Warning A change of the medicine device is pro hibited This device may not be changed without the manufacturer s authorisation If the medicine device is changed appropriate analysis and examination must be undertaken to ensure a safe continued use Use of additional devices Only additional appliances printer
27. r 2 million inputs optional 1x RS 232 other interfaces optional Bluetooth Quali fication Digital Indicator housing plastic weighing devices aluminium 130 160 mm max width 71 mm Memory capacity Interfaces Materials Wheels Other technical data Diagrams lists of spare parts and setting instruc tions can be requested through the manufacturer s Customer Service Instructions for installing the scale For design reasons the scale is designed only for use on level floors For installation sites in Germany this condition is met when the floor complies with the tolerance specifications for flat floors to DIN 18202 Table 3 Row 4 For other countries the applicable national standards should be taken as a basis WWW Soehnle medical nl Electronic nameplate and calibration counter The appliance has an electronic nameplate INFO inle 11 12 I 1 1 300kg J 500kg jJ 2kg 4kg 0 1kg ee Max SNR 000000 XXXXIX XXXXX GD D07 09 034 PTB M 07 YP 7711 XXXX Min PROFESSIONAL e C 07 ap Do7 09 034 PTB TYP XXXX WWW Soehnle medical nl Display by pressing the INFO key Exit the display by pressing the INFO key again d counter 6 1 sample display Weighing ranges Maximum load of weighing range Minimum load of weighing range Calibration value division Scale serial number scale type final number of year of manufacture incremental
28. rmat Organisation data Description of ORG A Description of ORG B ORG C ORG D User password New change To accept press ENTER for 3 seconds Select off or on Confir mation tone when a key is pressed Factory setting off Select off or on Valida tion tone when a function is executed factory setting off Enter into numerical key pad Press ENTER to start cock after confirmation Enter into KEYPAD Select European or imperial date factory setting Euro pean Enter the description of the organisation data memory A numerals or text entered into KEYPAD e g Bed number Room number max 12 characters Further input options for other organisation data memories see above Enter password with up to 8 characters into keypad after activation the Setting Clear Reset terminal Do not execute Executes mode is only accessible by password If you forget your password type in the word CLEAR to release access Clears the password and releases access Execute clears all all the individual terminal settings and resets to fac tory settings WWW Soehnle medical nl 5 FUNCTIONS Power on zeroing During the power on procedure the weight values sent by the weighing devices are zeroed until they are less than 50 of the max weighing range This tares the empty bed and the weight display goes to zero Manual zeroing Manual zeroing corrects minor devia tions from zero e g caused
29. ry and called up as required 100 different bed weights are possible Each memory location has a e Three digit consecutive number e Description text 18 characters e Tare value 18 Entering tare weights into the fixed tare value memory e Call up the input menu Setting mode gt Program Settings gt General gt Fixed tare values e Press ENTER and F key simultaneously to access Setting mode e The arrow points to Program Settings Confirm by pressing ENTER e Confirm the message General by pressing ENTER e Press TARE to browse to Fixed tare values and accept by pressing ENTER Entering values e f no tare memory has yet been assigned the first free or otherwise the last selected fixed tare value memory is displayed e Press ORG followed by ENTER The input field for the description of a new tare memory is dis played e tnter the description into the KEYPAD and con firm by pressing ENTER e The arrow points to Tare value Press ENTER The input field is displayed to enter the tare value e Enter the tare value and confirm by pressing ENTER e Go back by pressing the ZEROING key to select the tare memory e f you want to assign other tare memories press the ORG key to select the next free memory lo cation and repeat the procedure as described above e To return to weighing mode press the ZEROING key and then the ORG key WWW Soehnle medical nl Transferring fixed tare values from a PC to
30. s unsuitable or improper storage or use incorrect installation or putting into operation by the owner or third parties natural wear and tear changes or modifications in correct or negligent handling excessive use chemi cal electrochemical or electrical interference or hu midity unless this is attributable to negligence on the part of Soehnle Professional If operating climatic or any other influences lead to a major change in con ditions or material quality the warranty for perfect WWW Soehnle medical nl 5 ENGLISH BED SCALE 7711 a ee unit functioning shall be rendered null and void If Soehnle Professional provides an individual warranty this means that the appliance supplied will be free from faults for the duration of the warranty period Always keep the original packaging in case you have to return the scale 6 WWwW Soehnle medical nl 2 PUTTING INTO OPERATION Installing the scale elements The indicator s placement must allow for a simple disconnection from the power supply Insert rechargeable batteries in all four weighing devices When the batteries are fitted the weighing devices start to send and attempt to set up a radio link to the digital indicator Caution Fig 1 4 right Before switching on the scale place the weighing devices under the four wheels of the hospital bed Push the weighing devices as far as the stop under the wheels Press the lever down and raise the bed wheel The weig
31. the digital indicator Here you require a special software For more information please contact the Soehnle Profes sional Service personnel Changing or overwriting a fixed tare value memory Call up the Input menu Setting mode gt Program Settings gt General gt Fixed tare values Press ENTER and the F key simultaneously to access Setting mode The arrow points to Program Settings Confirm by pressing ENTER Confirm the message General by pressing ENTER Press the TARE key to browse to Fixed tare va lues and accept by pressing ENTER Correcting values The last selected fixed tare value memory is dis played Press the F or TARE key to select the tare memory to be changed or enter the memory lo cation number and confirm by pressing ENTER Press ENTER The input field for the tare location description is displayed Change the description by typing it into the KEYPAD and confirm by pressing ENTER The arrow points to Tare value Press ENTER The input field for the tare value is displayed Change the tare value by typing it into the KEY PAD and confirm by pressing ENTER Go back to the tare memory selection by pressing the ZEROING key WWW Soehnle medical nl If you want to change other tare memories press the F key of the TARE key to select the next memory location to be changed and repeat the procedure as described above To return to weighing mode press the ZEROING key and then the ORG key Call
32. unit When electrostatic interference is no longer present the appliance can again be used for its in tended purpose You may need to switch it on again The appliance is a measuring instrument Air currents vibrations rapid changes in temperature and direct sunlight may have an effect on the accuracy of the scale The scale is protected to IP 54 protection class Therefore avoid high levels of humidity vapours aggressive liquid media and strong contamination Warranty liability If the appliance is delivered with a fault or defect which is within Soehnle Professional s scope of re sponsibility Soehnle Professional is entitled to either repair the fault or supply a replacement appliance Replaced parts remain the property of Soehnle Pro fessional Should the fault repairs or replacement delivery not be successful the statutory provisions shall apply The period of warranty shall be 2 years beginning on the day of purchase Please retain your receipt as a proof of purchase If your scale requires servicing please contact your dealer or Soehnle Pro fessional Customer Service Only genuine spare parts may be used if an authorised service station carries out repairs Soehnle will only assume responsibility for the safety of the appliance if these instructions are observed and the appliance is operated in com pliance with the operating instructions No responsibility shall be accepted for damage caused by any of the following reason
Download Pdf Manuals
Related Search
Related Contents
important! - mystudiosync.com 平成23年4月の市公報(平成23年4月11日第267号)(pdf:7.8 My Book World Edition User Manual Samsung YP-U1Q User Manual LT Series User Manual - Pro Copyright © All rights reserved.
Failed to retrieve file