Home

User manual DC Safelog edition 2014-01-20 eng

image

Contents

1. User manual DC Safelog Edition 2014 01 20 DataChassi 2 User manual DC Safelog 1 TABLE OF CONTENTS LL TT 2 Presentation of the parts in DC Safelog rarrrnrnnrrnnnnnrnnrnnnrnnnnnrnnnnnernrnnernnnnnnnnnnnennnnnsennnnnenenne 3 Before using the alarm for the first time rrrnrnnnrnnnnnrnnnnnnrnnnnnrnnnnnnrnnnnvrnnnnnnnnnnnennnnneennvnnenenne 4 PETE 5 PEN 6 NTN 7 Appendix 1 Quick guide for using the Datachassi mobil applicatiON sssssssrisserrs 8 Appendix 2 Quick guide for operating of the DC Service portal rrrurrnnnnnnrnnnnrrnnnnnrnnrnnn NN X DataChassi 3 User manual DC Safelog 2 PRESENTATION OF THE PARTS IN DC SAFELOG Thank you for purchasing and using the DC Safelog it will help you keep thieves away and protect your valuable load The DC Safelog consists of the following parts 1 The main unit equipped with IR sensor 2 A220V battery charger 3 A24V battery charge cable The main unit consists of e Aruggedized casing that protects the alarm system and has two big handles on each side of the unit for easy handling e IR detector which covers 360 degrees horizontally and 150 degrees vertically e Built in GPRS communication and GPS module with internal antenna e Powerful neodymium magnets in the rear off the unit for easy attachment e Battery packs e A motion sensor Battery charger AC 120 240 Volts The unit can be char
2. ame on Notification in the Main dashboard If no date is shown right click and choose update on the menu Scroll down to the map and choose Zoom with to increase to decrease the scale Handling and control of the alarm functions DC Safelog Go to the Vehicle Dashboard platform name as above Scroll to the Subscribed applications and select run app on the line DC Safelog Activate deactivate the alarm by selecting Turn alarm on Turn alarm off It also displays if alarm function beep is activated or not This changed by selecting the Sound Alarm active Here you select how long the audio signal will be sounded by the Sound Alarm active seconds Return to Vehicle Dashboard platform name by selecting the arrow back top left of the screen Scroll down to the map and choose Zoom with to increase to decrease the scale X DataChassi 33 User manual DC Safelog Handling and control of the Tracking feature 1 Goto the Vehicle Dashboard platform name as above Scroll to the Subscribed applications and select run app on the line DC Tracking 3 Activate deactivate the alarm function by selecting Turning tracking on Turn off Wait 30 seconds then right click and select update in the field Then select the positioning range by clicking on the down arrow on the line Update interval and select the time interval by selecting t
3. as good view over the goods as possible Do not cover the IR sensor The DC Safelog will cover up to a 10 meters radius 360 degree horizontally and 150 degrees vertically when mounted at a height of 2 5 3 5 meters Since the system is equipped with strong magnets no magnetically sensitive parts such as credit cards computers hard disks etc should be close to the magnetic part of the alarm 5 OPERATING THE ALARM When the alarm is in place and where appropriate programmed into the portal it can be operated as follows Via an App in the Android Smartphone See Appendix 1 Through the DC Service portal By logging in to the DC Service portal alarm can be remotely controlled see Appendix 2 6 CHARGING THE ALARM A normal charging is performed during 6 8 hours or less depending on how much the unit has been used The lifetime of the battery is extended if the battery is never completely depleted and if charging is avoided when the unit temperature is below zero degrees X DataChassi 5 User manual DC Safelog 7 APPENDIX 1 QUICK GUIDE FOR USING THE DATACHASSI MOBIL APPLICATION Below is a quick guide to get started using Datachassi mobile phone application for monitoring and control of Datachassi s alarm system via a mobile phone Start the DC Mobile Application Restart the phone as the phone manufacturer s functional description Select the DC on the phone s main menu Wait until the dialog Pl
4. ease enter your PIN code is displayed to enter the assigned PIN Activate the keyboard by pressing the black dialog box and enter the assigned PIN and finish by selecting Klar and then OK After the above described log appears after a minute dialog DC by which the control of a number of features are enabled Upper half of the display contains two windows In the top of the upper window Platform is the choice of the platform to be used with the phone app is made In the bottom of the upper window Battery and Alarm displays battery strength and checked the alarm on off function Lower half of the display contains three fields Start Driving Mode chooses the field for emergency alarm Lock locks the app but is still operational and locked up again with PIN Exit terminates app feature Enable disable the app feature 1 2 Select the alarm system to be used by the phone app by pressing the field to the right of the Platform Then select the alarm system by pressing the ring to the right of each name on the alarm system Activate your selection by pressing the Aquire Platform Control After a few seconds this lower windows functions selectable confirming that the phone app is approved by the DC Service portal to check the selected alarm system To select a new alarm system touches the bar with the text Release Platform Control After a few seconds the bar to the right of the Pla
5. ged by connecting the AC 120 240V battery charger to the unit AP Battery charger cable 24 Volts The unit can also be charged while it is inside a truck by connecting the battery charging cable between the truck cigarette lighter socket and the unit 3 BEFORE USING THE ALARM FOR THE FIRST TIME Please inspect DC Safelog paying special attention to any possible transportation damage particularly the IR sensor Before the alarm is used for the first time you need to register your equipment in Datachassi s Service Portal In the portal you will also be able to choose how you wish to control your DC Safelog This can be done from either from the portal or a mobile phone Android Any cracks could allow moisture to penetrate into the electronics and can seriously damage the unit Dirt including dust and oil must be removed before use in an appropriate manner from the sensor s protective dome DO NOT use strong solvents for cleaning as they may do X DataChassi A User manual DC Safelog more harm than good and can make the alarm inoperable or cause it to not work as intended If cracks or damage to the device are discovered please contact your supplier The alarm should be fully charged before used the first time charging can take up to 12 hours 4 PLACEMENT OF THE ALARM Place the alarm in a suitable location using the alarm s magnetic holder at the rear of the unit casing Make sure the alarm has
6. he chosen Activate by clicking on Turn on tracking 4 Return to Vehicle Dashboard platform name by selecting the arrow back top left on the car s screen Scroll down to the map and choose Zoom with to increase to decrease the scale Note If this action would not function continue with pt 5 below 5 Return to Vehicle Dashboard platform name by selecting Main dashboard 6 Choose any platform in the Platform name on Notification in the Main dashboard If no date is shown right clicks and chooses update on the menu 7 Scroll down to the map and choose Zoom with to increase to decrease the scale 9 CONTACT OO ae X DataChassi Datachassi AB Gjutarv gen 1 SE 544 50 Hjo Sweden info datachassi com Service phone 46 708 32 06 21 X DataChassi
7. pplication has been activated and the functions to be activated is completed should the Start Driving Mode in the lower half of the display can be selected to obtain the ability to emit emergency alarm 2 In an emergency press the red field with the text Emergency and then the phone app automatically sends an emergency message to the DC Service portal for forwarding to the selected recipient 3 To return to normal mode phone app touch the bar with the text Hide Locking the phone app 1 By choosing Lock in the lower half of the display is locked phone app and PIN must be re entered as described above none in order to unlock the phone app While the phone app is locked persists the connection towards the DC Service portal and data transfer continues X DataChassi 7 User manual DC Safelog End phone app feature 1 Select Exit in the bottom half of the display and then OK to leave the mobile phone application 8 APPENDIX 2 QUICK GUIDE FOR OPERATING OF THE DC SERVICE PORTAL Below is a quick guide to get started using the DC Service portal for monitoring and control of Datachassi s alarm system via the portal Monitoring of vehicle movement POA e N FR Start the web browser such as MS Explorer alt Google Chrome Enter the URL www datachassi com Select the tab Login Please enter the email address and password and then select the Log in Choose any platform in the Platform n
8. tform selectable and then proceed in accordance with paragraph 1 and 2 above X DataChassi User manual DC Safelog Activate deactivate the alarm function 1 Activate the alarm by selecting the Arm then the text will turn blue with the text Arming and then when the alarm is activated turn green with the text Armed and that the box on the right with the text Disarm is selectable 2 To deactivate the alarm select the Disarm and the alarm is deactivated when the blue text Disarming message which then turns green with the text Disarmed and the box to the left with the text Arm will be selectable Handling on activated alarm 1 When triggered the mobile phone emits the selected signal and a dialog box displays with red text Fired 2 Deactivate the alarm by pressing the box with the text Disarm Then the display boxes according to paragraph 2 above Checking the battery status 1 When the mobile application has been activated as above will automatically battery Status display with figures of different colour in the field to the right of Battery This shows how much battery is left At more than 24 hours the time in days d with green text and less than 24 hours the time in hours hrs with the first yellow and then red 2 TO manually update the battery status press the green arrows to the right of the numbers Alarm in case of emergency 1 When the mobile a

Download Pdf Manuals

image

Related Search

Related Contents

Section 1 - Community Transit  Ice-O-Matic IOD200 User's Manual  version française - Pr. François Duret  BioMAT® 2 Safety Cabinet  Dress Shop User Manual  取扱説明書 施工要領書  hdpowerwasher.com - Power Washers from Power Washer.US    

Copyright © All rights reserved.
Failed to retrieve file