JDSU ONT-601 MTM Quick Start Guide

image

Contents

1. 2011 JDS Uniphase Corporation 21162407 003 1211 ONT 601MTM QC OPT TM AE
2. may be con nected back into your LAN infrastucture Connecting and using the GUI System 1 Open your internet browser ATTENTION The web browser that you use to display the MTM GUI maintains a cache of recently accessed web pages It may be necessary to manu ally clear the cached files before launching the Application GUI 2 Exclude the IP address of the MTM from using the Proxy Server if one is configured for your browser 3 Enter the IP address of the MTM to which you want to connect into your browser s ad dress field to run the Java Applet and launch the GUI 4 Select the Accept button if you are presented with a security certificate Page 3 5 Once the GUI is displayed select Launch Application GUI link ONT 6xx at 10 13 154 161 Windows Internet Explorer provided by JDSU E ioj xj go O http 10 13 154 161 Xil Live search File Edit View Favorites Tools Help We d CY ONT 6xx at 10 13 154 161 fh B o ah EY Page G Toos You are connected to ONT S 0011 10 13 154 161 REMOTE OPERATION 6 Select the port that you wish to connect to and select OK 7 Highlight New Application and then select the Load button 8 Select the Signal Structure pull down and select the protocols you wish to test Ed 10 E 216 x File Applications Results Tools Help 11 17 Overview Application Configuration Config z Select Applicatio
3. JDSU ONT 601 MTM Quick Start Guide Version 1 2 This guide will assist you with the initial configuration of your ONT 601 MTM to have you up and running in minutes For further details on the initial setup and use of your ONT product please refer to the ONT 601 MTM user manual What you need to start e An external PC running Java version 6 0 e A network LAN connection for the PC and MTM or alternatively an Ethernet cable for direct connection The MTM has an auto sensing LAN port so a straight through or crossover cable will both operate correctly e The MTM connected to a power source using AC power cord compatible for your area Note that a power cord is shipped with every new unit from the factory Minimum PC system requirements ONT 601 MTM operation requires the following minimum requirements for the user PC e Microsoft Windows XP Vista or Windows 7 or alternatively an equivalent Linux environ ment e Pentium 4 1500MHzZz or equivalent with 512M of RAM OS may require faster processor e LAN connection capability e One of the following Internet browsers Microsoft Internet Explorer 6 0 or higher or Mozilla Firefox 3 0 or higher e Java Runtime Environment JRE Plug in Version 6 0 1 6 x Installation of optical interfaces Install an SFP and or XFP into each port that you will be using on the MTM Enabled Enabled V15 x V15 x zs 3 See eeeeo0 s on aE ASRS lene k lro R Note For Softwar
4. TM is shipped from the factory for this type of connection L Connect an RJ 45 cable from the MTM faceplate Ethernet port to your network hub or remote jack Power on the MTM and a DHCP request is issued on boot up If the MTM has already been powered on you may depress the recessed black IP reset but ton highlighted within the white box below with a paper clip ball point pen or similar instrument until the red LED illuminates and hold for a minimum of 2 seconds Ensure to only depress the button until it reaches the end of its travel to avoid damage to the switch Verify the IP address and netmask have been correctly assigned by checking the LCD display on the front panel Note If the default IP address 192 168 0 101 is shown on the LCD display then the DHCP server is not available or there was a LAN issue that prevented the MTM from acquiring a DHCP address from the server If this happens try rebooting the MTM try using the Static IP procedure instead or consult with your network administra tor Existing LAN Infrastructure Static IP Use this method when a static IP address will be assigned to MTM Note that the IP address must be unique for your network i e not in use by another device to avoid any conflict Please consult your network administrator if necessary L Go through all of the steps described in Direct to PC Connection or Existing LAN infrastructure DHCP assigned addressing depending o
5. e V 1 x only XFP ports 1 and 3 are enabled No SFP ports For Software V15 x only XFP SFP port 1 and 3 are enabled LAN connection and configuration Select one of the following methods to connect and configure the MTM for LAN communica tion Direct to PC connection Use this method when connection is direct to a local PC 1 Connect a RJ 45 Ethernet cable from the MTM faceplate Ethernet port to your PC LAN port 2 Power on the MTM and wait for the CPU light to start flashing 3 If you received the MTM new from the factory you may skip this step Depress the recessed black IP reset button highlighted within the white box on page 2 with a paper clip ball point pen or similar instrument until the red LED illuminates and hold for a minimum of 2 seconds Ensure to only depress the button until it reaches the end of its travel to avoid damage to the switch This will set the ONT 601 MTM to its default IP address 192 168 0 101 This default address is only valid until the next re boot of the unit After re boot the 4 D JDSU Page 1 www jdsu com test ONT 601 MTM will either look for a DHCP assigned address or default to its fixed address see next chapters On your PC configure the following network settings e IP Address 192 168 0 100 e Subnet mask 255 255 255 0 e Default gateway 192 168 0 1 Existing LAN Infrastructure DHCP assigned addressing Use this method to assign the MTM IP address using a DHCP server The M
6. n Configuration Status Device Mode Terminate 7 over D Signal Structure Unframed af Signal Structures gt B Unframed LAN EE OTN SONET SDH 9 Once the application is loaded you will receive a control panel which has each of the protocol layers displayed Current Errors MAC SIP Pcs OTN PHYS 4 10 13 155 154 Slot 1 1 New Application a 0 x Eile Applications Results Tools Help 10 12 Overview Application Configuration Device Mode Terminate Signal Structure OTN 10GigE LAN L2 L3 Traffic 11 049 Ghis 11 049 Ghis OTU2 overclocked OTU 2 overclocked 64B 66B 64B 66B IP disabled MAC IP MAC IP IP disabled 10 The Laser is turned off on start up The Alarm status is shown on the left side of the GUI Selecting individual Layer tabs will present various chapters for Configuration Status Alarm and Error Injections and other Layer specific tools Questions or Problems Please refer to the User Manuals that are installed on the ONT 601 MTM or available via the Help tab on each layered protocol on the GUI If you still require assistance please contact the JDSU Technical Assistance Center O gt lt Americas 1 866 228 3762 Option 3 Option 1 EMEA and APAC 49 7121 86 1345 Americas tac jdsu com EMEA and APAC hotline europe jdsu com lt gt JDSU Product specifications and descriptions in this document are subject to change without notice
7. n which of the two apply to your setup Go through the steps described in Connecting and using the GUI system on page 3 until you see the Welcome to ONT 601 MTM 4s4x page Now select Launch ONT Scout link in order to get access to the IP setup function Page 2 4 Select View gt Find ONT and enter the range of the subnet currently configured Entering the start address will automatically fill in the end address based on the IP subnet mask used SS Cl Set additional IF addresses for searching ONTs from 192 168 0 1 to 192 168 0 254 5 Select the module configuration button for the MTM You are prompted for the Administrator password This password is Administrator by factory default 7 ONT Scout a DEN View Software Update Help State V Module V SerialNo V IP Address Vv Mainframe Slot V SW Release v Usage NONE y Co MTM Module AA 014 10 49 74 81 ONTOS 1 ontBxemtm 15 0 2 0007 Kah D Bou gt ee 6 Enter the new IP address information required for your network Configure MTM Module AA 014 10 49 74 81 E Network settings l Software update Reboot Configure network settings O Obtain from DHCP server IP address 10 49 74 81 Subnet mask 255 255 255 0 Default gateway 10 49 7 4 1 Use the following IP address 7 Select OK If you used the Direct to PC Connection method the MTM