Home
USER MANUAL - POOL TECHNOLOGIE
Contents
1. Connect the pump to the controller Type 2 pumps disinfectant pH Place the first saddle and accessories as per Type pump v Place the second saddle at a minimum distance of 50 cm from the first one Turn the opening 2 upwards Mark then drill the pipe Mount the injection connector 12 with Teflon The injection connector should be as close as possible to water pushing in to the pool Y Connect the suction strainer to the pH pump with a part of the tubing supplied The arrow on the pH pump cover indicates the flow direction Y Connect the outlet of the pH pump to the injection connector with a piece of the tubing supplied Connect the pump to the controller IV ACTIVATION A INTRODUCTION A When installing the device for the first time or at the start of a new season it is imperative to check and adjust the following 3 points v The pool water must be clear and free from algae or sediment v The water should be correctly balanced alkalimetry hydrometry e Alkalimetry shows the level of bicarbonates dissolved in the water e Hydrometry shows the water hardness that is the level of calcium or magnesium salts dissolved in the water v The pH of water should be stabilised between 7 0 and 7 2 A The efficiency of a chlorine chemical treatment is rapidly decreased by the increase in pH and scale precipitates more quickly when pH is high or unstable Effectiveness of chlorine b 7 80 5
2. MA flashes in the display Y Choose the SE function with the buttons then confirm with V Y Choose rE with the 0 buttons then confirm with V v The display flashes with the stored details Y Choose the desired value with within 500 to 900 mV then confirm with V The Redox regulation will be from now at the new chosen value 6 Adjustment of the pH set point The pH set point by default is 7 2 It is however possible to modify this set point to fit the features of your pool water Press the V button for 3 seconds MA flashes in the display Choose the SE function with the buttons then confirm with V Choose the PH function with the O buttons then confirm with V The display flashes with the stored details Choose the value you want with within 6 8 to 7 6 then confirm with V The pH regulation will from now on be at the new value chosen SONNE N 7 Manual injection This function allows you to carry out manual injection of a disinfectant or pH corrector product for an adjustable amount of time 11 Press button V for 3 seconds MA flashes in the display Select the MA parameter and confirm with V Select the desired product rE disinfectant or pH pH correcting agent Select the dose from 0 to 990 ml for the disinfectant or a time from 0 to 9 5 mn for the pH with the QObuttons then confirm with V Caution a read out of 15 means 150 ml while 1 1 means 1 mn and 1 second v Injection starts Af
3. The filtration box power supply line should be protected by a differential circuit breaker with a release security of 30 mA maximum with an opening distance of at least 3 mm on all poles This circuit breaker has nothing to do with the house s one from 300 to 500 mA In case of doubt get a qualified electrician to look at the installation The electrical installation of this equipment should be performed by a qualified person in accordance with the regulation in force in the region concerned The power supply cables must be protected against accidental damage A damaged cable should be replaced immediately and exclusively with an original cable Never cut or extend the cables It is important to turn off the power supply before carrying out any technical work Do not modify the device Any modification may cause damage or be dangerous Only qualified personnel should carry out maintenance in case of break down This device is intended for use in family pools only NON OBSERVANCE OF THESE INSTRUCTIONS MAY CAUSE DAMAGE TO THE DEVICE OR SERIOUS INJURY Il PACKING LIST Before starting installation ensure that the box contains Type Type 1 Pump 2 Pumps 1 User manual 1 User manual 1 Controller electronic box 1 Controller electronic box 1 Peristaltic pump 2 Peristaltic pumps 1 REDOX probe 1 REDOX 1 pH probe 5 m colored tubing 5 m transparent tubing for pH 5 m
4. new product which is more or less the same you can bring it back to the distributor when you are buying a new one e Take it to a waste recycling facility The symbol a stamped on a product means that a selective collection is necessary and that it must be sorted from other household waste Manufactured by POOL TECHNOLOGIE Zac des Jasses 115 rue de Oliveraie 34130 Valergues France www pool technologie com 16
5. 0 40 30 20 etl b gt gt 8 8 70 72 T4 76 78 80 Source French Ministry of Health B INSTRUCTIONS All models The Redox and pH probes have been calibrated in the factory no calibration needs to be carried out before first using the device It is necessary to set the device according to the pool volume and the used treatment agents Please follow the instructions outlined in chapter V The activation of your device is now completed We recommend you to activate your guarantee on www pool technologie com It will enable you to receive information on your device V MAINTENANCE A Never use hydrochloric acid Only use a pH corrector product acid or base which is recommended by your professional The use of any other chemical product can lead to irreversible damage to the device A Use exclusively a disinfectant made from chlorine recommended by your professional sodium hypochlorite or soda hypochlorite The use of any other chemical product can lead to irreversible damage to the device A It is IMPERATIVE to check the levels of chlorine and pH each week with your usual analysis kit An excessive level of chlorine and or a low pH is likely to cause oxidation of the metal parts and can lead to non reversible deterioration of the pool surface axes and automatic shutter flaps telescopic shelters thermal exchangers If you are covering the pool shutter tarpaulin cover ventilate the pool regula
6. CE USER MANUAL JUST DOSING REDOX 1 pump and 2 pumps JUST DOSING l J w wp FAMILY POOLS UP TO 160 m Ref PAPI004063 GB 05 09 TABLE OF CONTENTS I SAFETY INSTRUCTIONS I PACKING LIST IMI INSTALLATION IV ACTIVATION V MAINTENANCE VI ALARMS VIL WINTERING VII WARRANTY IX ENVIRONMENT PRESERVATION Pool Technologies declares this equipment complies with the following E U directives Electromagnetic Compatibility Directive 89 336 EEC modified 92 31 EEC and 93 68 EEC Low Voltage Directive 73 23 CEE modified 93 68 EEC Chief Executive Rm oo To improve product quality the manufacturer reserves the right to modify production at any time and without notice I SAFETY INSTRUCTIONS READ AN FOLLOW ALL INSTRUCTIONS SAVE ALL INSTRUCTIONS A In the manual this symbol indicates a WARNING It informs you of the risk of damage to the equipment or of serious injury It is very IMPORTANT that you pay attention to these warnings WARNING RISK OF ELECTRIC SHOCK The safety instructions outlined in this manual are not exhaustive They highlight the most common risks of using electrical equipment in presence of water Any installation and use of this equipment should be carried out with caution and common sense A To prevent injury or accident install the equipment out of the reach of children Ensure that the installation conforms to the regulation in force in the region concerned
7. H Alarm Check the value of the pH in the pool using your usual analysis kit If the pH is abnormal stop the device Add a pH acid corrector Alarm pH high or pH base Alarm pH low directly in the pool through the flow out pipes Restart the device If the pH is normal adjust or calibrate the pH probe 2 Flashing AL display The device has detected that the previous correction attempts have failed v Check that the disinfectant and or pH corrector and tank are not empty Y Check that the pumps are injecting properly refer to chapter V paragraph Y Check the probes comparing the values indicated by the device with the measured values in the pool with your usual analysis kit v Check the condition of the extraction and injection valves Check the volume of the pool refer to paragraph V Y Do not hesitate to visit our FAQ on www pool technologie com If you do not find solution to your problem contact our Technical Assistance Service on N INDIGO 0 892 705 520 from France 0 34 TTC MN Please supply Y Proof of purchase Y Serial number of the controller and the pH probe vY Date when the device was installed v Name of the professional shop where it was purchased and or who installed the equipment v You will be asked pH value chlorine level water temperature stabiliser level pool volume time of daily filtration 13 VII WINTERING When wintering the pool emptying the pool and or stopping filtration
8. carry out the following maintenance operations v Remove the pH probe and keep it in the rubber protection filled with tap water v Rinse the flexible tube of the peristaltic pump with clean water Changing the pump tubing Replace the flexible tubing from the peristaltic pump each season the check valves The maintenance kit R f KITOZMAINMTP contains all of the parts necessary for annual maintenance operation IX WARRANTY All our care and technical expertise has gone into making this device It has undergone quality control If in spite of all care and knowledge which has gone in to its manufacture you have to use our warranty free replacement only applies to parts of our equipment which are defective Duration of the warranty 2 YEARS for New material controller 1 YEAR for the pH probe basic probe excluded 1 Month for After Sales Repairs and spare parts Authentic invoice date Warranty objects The warranty applies to all parts with the exception of consumables which must be replaced regularly The device is covered for any manufacturing defect only when it has been used normally in a family pool Use in public pools voids the warranty After sales service v All repairs are done in our work shop All transport fees are payable by the user There will be no compensation for immobilisation and privation of the equipment when it is being repaired v In any case the equipment is always carried at the user s o
9. coloured tubing for REDOX 1 inlet filter 2 inlet filters 1 control panel with probe holder filter and mounting set 1 control panel with probes holder filters and mounting set 1 Injection connector 1 2 2 Injection connectors 1 2 check valves 2 inserts and 2 fixing screws 2 inserts and 2 fixing screws 1 kit for assembly panel connection 5 m clear tubing 2 fittings 1 2 2 saddles 50 mm x and 2 small valves M F 2 1 kit for assembly panel connection 5 m clear tubing 2 fittings 2 saddles 50 mm x 1 2 and 2 small valves M F 2 1 saddle 50mm x 2 saddles 50 mm x 1 2 II INSTALLATION A INTRODUCTION This manual covers the 2 automatic dosing models e Model 1 pump for the simple disinfection of the pool e Model 2 pumps for the disinfection and the pH regulation of the pool A setore proceeding with the installation of the device it is very important to check the following points v The technical area should be dry and properly ventilated protected from rain splashes discharges of water and UV radiation Provide a space for each which is at a sufficient distance from the electrical appliances or any other chemical containing product Non compliance with this instruction will lead to abnormal oxidation of the metallic parts which may result in the device break down v Assembly of the dosing cont
10. e installation diagram S The valves mounted on the saddles allow isolating the measuring circuit Another valve placed between the 2 filters allows the water sampling for measurements by photometer for example Assembly panel connection S Place the first saddle Mark then drill the pipe Mount the small valve on the saddle with Teflon Mount the fitting M on the small valve lt S Place the second saddle Mark then drill the pipe In the same way mount the small valve on the second saddle with Teflon Mount the fitting M 2 on the small valve S Take off the rubber protections from the probes then mount them on the corresponding probe holders Ensure it is not stuck in the pipe S Connect the cables from the REDOX and pH probes BNC plugs to the bottom of the controller Keep it away from all other electric cables to avoid any electromagnetic disturbance which may distort measurements 3 Accessories Type 1 pump disinfectant v Place the first saddle in the middle of a horizontal pipe of a minimum of 40 cm turning the opening 1 2 preferably upwards Mark then drill the pipe Mount the injection connector on to the saddle with Teflon Y Connect the inlet filter to the pump with a part of the coloured tubing supplied Follow the direction of the arrows on the cover of the pump Y Connect the outlet of the disinfectant pump to the injection connector with a piece of the tubing supplied
11. ion on your device v No part replacement will be made without the defective part being returned beforehand Any part which is not returned will be charged at the current tariff Laws and disputes v The present warranty is subject to French law and all other European directives or international treaties which are in force at the moment of complaint and which are applicable in France In the event of dispute with regard to its interpretation or its execution this is the remit of TGI de Montpellier 15 IX ENVIRONMENT PRESERVATION Environment preservation is essential Our company is very much involved in this Our products are designed and manufactured with materials and components which are of a high quality respect the environment and are reusable and recyclable However the different components of which they consist may not be biodegradable Our products should not just be discarded European environmental directives set for each product category appropriate methods of managing and disposing of waste material The aim is to reduce waste material and to use it avoid making their components become a danger and to encourage the products to be reused To carry out this policy successfully product manufacturers distributors users and even professionals are involved in managing waste material from these products Since August 13 2005 a European directive means you can dispose of your used product free of charge e If you buy a
12. ith V The display shows the 1 point of calibration by flashing 7 Place the pH probe in a standard pH 7 solution then confirm by V Please wait Calibration is automatic the display will flash alternatively 7 and If the measured value is correct the display will read Oh Rinse the pH probe then let it drain After 3 s the display will then show the 2nd calibration point by flashing 10 Place the pH probe in the pH 10 solution then confirm with V Please wait Calibration is automatic the display will flash alternately 10 and If the measured value is acceptable the display will read Oh for 3 s The new parameters are then stored v The device will automatically move into regulation mode after 3 secs Stop the filtration v Put the probe back into its holder then put filtration to AUTO mode SN RNS S SS If the calibration does not work v The display reads Er for Error Pressing Stop Start or V will clear the message v The previous parameters remain stored y Contact a professional You may need to replace your pH probe 12 A The calibration solutions are disposable They can be kept for 1 year in their vacuum sealed packet stored away from light and heat Dispose after use A Never dry the pH probe with a cloth or absorbent paper since it may damage it Leave it to drip dry VII ALARMS 1 Flashing pH displa The device has detected an abnormal pH value gt 1 High pH Alarm or pH lt 1 low p
13. nfectant regulation The injection of the disinfectant is automatically carried out according to the Redox set point you will adjust and the daily recommended dose advised by the disinfectant provider Example Recommended dose 900 m1 100 m day If your pool capacity is 50 m the daily dose do will be 450 ml pH regulation The injection of the pH correcting agent acid or base to set in Co menu is automatically carried out according to the set point and the pool volume CP B INSTRUCTIONS To modify the parameters of a function Hold the button V for 3 secs to access the parameters which can be modified v Choose the code of the parameter to modify using the O buttons then confirm with V v The parameter to modify flashes y Choose the desired value using the buttons then confirm with V lt S v The value will be displayed for 3 secs The device then automatically returns to the main display Button C allows you to stop the operation in progress at any time and to return to the main menu 1 Start Stop This function allows you to stop or start the device again at any time v Press and hold C for 3 seconds 2 Adjustment of the pool volume This function allows you to adapt the quantity of product to be injected according to the volume of the pool The volume by default corresponds to pools from 30 to 35 m code 15 Pool volume code Pool volume Code Pool volume Code 0m t
14. o 1m 01 10 m to 15 m 11 60 m to 70 m 21 15 m to 20 m 12 70 m to 80 m 22 20 m to25 m 13 80 m to 90 m 23 25 m to 30m 14 90 m tol00m gt 24 30 m to 35 m 15 100 m to 110m 25 35 m to 40m 16 110 m to 120 m 26 40 m to 45 m 17 120 m to 130 m 27 45 m to 50 m 18 130 m to 140 m 28 50 m to 55 m 19 140 m to150m 29 55 m to 60 m 20 150 m to 160 m 30 Each code corresponds to an injection time for the disinfectant and the pH corrector Due to the nature of water it may be necessary to adapt the average timing gt Press the V button for 3 seconds MA flashes gt Choose CP using the buttons then confirm with V gt The display flashes and shows the default value code 15 when first installed gt Choose the code which corresponds to the volume of the pool using the 0 O buttons then confirm with V gt The display stops flashing After 3s the device automatically goes to regulatory mode 3 Adjustment of the disinfectant dose Just Dosing Redox may be used with all type of available disinfectant products Do menu allows setting the daily dose according to the product manufacturer recommendations Example recommended dose 900 ml 100 m day If your pool capacity is 50 m the daily dose do will be 450 ml 10 Pool Hypochlorite concentration at 2 7 Hypochlorite concentration at 9 6 Hypochlorite Concentration at 8 5 chlorometric degrees 35 chlo
15. rly so as to avoid dissolved gases accumulating which could disrupt the measurements of pH or chlorine probes The manufacturer is not liable for the non observance of the maintenance instructions Your device allows you to carry out different operations detailed below Button C allows to you stop an operation which is running at any time so you can go back to the main menu A INTRODUCTION Depending on the model 1 or 2 pumps the device may have the following functions disinfection pH 1 Display 2 pumps model The display alternatively shows the Redox or the pH value Example II Mo gt i 7 0 stands for a pH value of 7 75 stands for a redox value of 750 mV 2 A scrolling menu allows setting the JUST DOSING REDOX 1 MA manual injection for disinfectant and pH 2 Ad adjustment of Redox and pH probes 3 CA pH probe calibration 4 CP pool volume 5 Co pH correcting agent 6 SE pH and redox set point 7 do daily dose 8 OP empty can function option Summary of the menu OO o a peo Oe eee eee a O SS seeen Param tre Volume pH Mse en route 15 par d faut AC par BCL BA d faut Correcteur pH p r 1 Consigne pH R glage de 5004900 780mVpar do mode z pas de 10mV do d faut dosage Consigne REDOX R glage de 0 990m1 50 par Param tre dose RE pas de 10mI d faut journali re en ml M OFF par i A Le l HH or jea S F Disi
16. roller and its attachments must strictly conform to the following installation diagram Installation diagram JUSTDOSING Redox pH probe filter T probe Sampling valve CHLORINE CONTAINER CORRECTOR FLOW IN CONTAINER A For the model 2 pump follow the mounting order of the probes on the control panel Also follow the order of correcting agents installation order A For the model 1 pump the Redox probe and the filter must be mounted on the left entry of the control panel B INSTRUCTIONS 1 Controller electronic box Y Choose an area which is easily accessible close to the electronic filtration box Install the controller vertically far enough away from the pool to respect the regulation distances of your own country Do not cover it A Any contact between the controller and the water in the pool may risk electrocution v The controller must be permanently connected to the filtration controller and slaved to the pump contactor Do not use an extension cord with a plug or use a plug to connect the unit Turn off the differential circuit breaker beforehand Ensure that the controller switches off when the filtration pump stops 2 Assembly panel Y Choose an area which is easily accessible close to the controller and to the filtration box Install the controller horizontally use the connection set in order to connect it in parallel with the sand filter as per th
17. rometric degrees 12 5 50 chlorometric 10ml do 10 100ml do 10 Cim eel 500ml do 50 300ml do 30 i eee 850ml do 85 500ml do 50 ETER 990ml do 99 600ml do gt 60 oom eee eee 990ml do 99 Press button V for 3 seconds MA flashes in the display Select the do parameter and confirm with V 50 is displayed as default or the last saved value in ml Select the dose from 0 to 990 ml using the buttons then confirm with V Caution a display of 15 means 150 ml After 3 secs the device automatically goes to the main menu SONOS SS lt S 4 Adjustment of the pH corrector type The device has a default setting for using an acid corrector product It may be necessary to modify this regulation acid base adapt it to the characteristics of the water in your pool v Press button V for 3 seconds MA flashes in the display yY Select the function Co with the buttons then confirm with V yY Select by an acid product AC or base bA then confirm with V The display stops flashing and after 3s the device automatically goes to regulation mode 5 Adjustment of Redox set point The Redox set point by default is 780 mV This value corresponds to an efficient disinfection rate for a pH regulated around 7 2 JUST DOSING REDOX allows you to modify the set point in order to fit the own features of your pool water Vv Press the V button for 3 seconds
18. ter 3secs the device automatically goes to the main menu SASS 8 Adjustment of the probes This function allows you to adjust the values measured by the device and the values you have measured in your pool with your usual analysis kit Press button V for 3 seconds Ma starts to flash Choose function Ad using the 9 Q buttons then confirm with V Select the desired product rE disinfectant or pH pH correcting agent The display flashes the current value Select the desired value using the buttons from 400 to 800 mV for the disinfectant and from 6 8 to 7 6 for the pH then confirm with V If the selected value is acceptable then the display shows Oh during 3 s The new value is then saved v After 3 secs the device automatically goes to regulation mode SAN OREN In case of failure in adjusting a probe v The display shows Er for Error Push the button ON OFF or V to erase the message v The previous value remains stored 9 Calibration of the pH probe Each pH probe has its own characteristics To regulate pH effeciently it is recommended that a calibration pH probe be made at the start of the season and after any change of the pH probe Y Check that you have pH7 and pH10 solutions not supplied Y Stop filtration Remove the probe from its holder and replace it with a coin Then set filtration to MANUAL mode Hold down the V button for 3 seconds MA flashes Choose function CA using the 9 O buttons then confirm w
19. wn risk It is up to the latter to check that it is in perfect condition before the order is collected and if need be to state any reservations on the carrier s slip Confirm this with the carrier within 72 hours by registered letter with an acknowledgement of receipt IMPORTANT A replacement under guarantee will on no account extend the initial warranty 14 Limit of the warranty Not included in the warranty 1 Equipment and labour provided by a third party at the time of the installation of the equipment 2 Damage caused by an installation which is non compliant 3 Problems caused by deterioration accident harsh treatment professional negligence or by the final user non authorised repairs fire floods lightening frost armed conflict or any other force majeure ATTENTION The warranty does not cover any damaged equipment further to non respect of security use rules use and maintenance stated in the current manual Every year we improve our products and software These new versions are compatible with previous models New versions of equipment and software are not added to the warranty from the previous models Implementation of the warranty y For more information on the current warranty contact your professional or our After Sales Service Any request should be accompanied by a copy of your proof f purchase Y Do not hesitate to activate your guarantee on www pool technologie com It will enable you to receive informat