1. IES 3240 Industrial Managed Ethernet Switch User s Manual Version 2 1 Oct 2012 www oring networking com ORing Industrial Networking Corp 0 ORing Industrial Networking Corp yo IES 3240 User s Manual COPYRIGHT NOTICE Copyright 2010 ORing Industrial Networking Corp All rights reserved No part of this publication may be reproduced in any form without the prior written consent of ORing Industrial Networking Corp TRADEMARKS omo e is a registered trademark of ORing Industrial Networking Corp All other trademarks belong to their respective owners REGULATORY COMPLIANCE STATEMENT Product s associated with this publication complies comply with all applicable regulations Please refer to the Technical Specifications section for more details WARRANTY ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date 5 years for most products ORing will repair or replace products found by ORing to be defective within this warranty period with shipment expenses apportioned by ORing and the distributor This warranty does not cover product modifications or repairs done by persons other than ORing approved personnel and this warranty does not apply to ORing products that are misused abused improperly installed or damaged by accidents Please refer to the Technical Specifications section for the actual warranty period s of the
2. System Name IES 3240 Industrial 24 port managed EUNT Ethernet switch with 24x10 100Base T X I System Location System Contact MA SNMP OID 1 3 6 1 4 1 25972 100 0 0 53 Firmware Version Kernel Version MAC Address 00 1E 94 00 12 34 O Day s O Hour s 36 Min s 28 MM Warning Monitor and Diag Save Configuration Factory Default System Reboot T Enable Location Alert Hel Logout ne Lot Main interface ORing Industrial Networking Corp 15 IES 3240 User s Manual 5 1 2 System Information System Information System Name IES 3240 Industrial 24 port managed Ethernet switch with System Description 24x10 100Base T X System Location System Contact SNMP OID 1 3 6 1 4 1 25972 100 0 0 53 Firmware Version Kernel Version MAC Address 00 1E 94 00 12 34 System Uptime 0 Day s 0 Hour s 37 Mints 8 Sec s System Information interface System Information The system information will display the configuration of Basic Setting Switch Setting page Enable Location Alert When click Enable Location Alert PWR1 PWR2 and PWR3 LEDs of the switch will start to flash together and click Disable Location Alert the LEDs will stop flashing 5 1 3 Front Panel Show the panel of IES 3240 Click Close to close panel on web ORing Industrial Networking Corp 16 IES 3240 User s Manual 5 1 4 Basic setting 5 1 4 1 Switch Setting System Setting System Name IES 3240
3. cesis cerns e in hn mre ae dae acct rua xh reer 9 3 1 Fron Panel aaa a Re TE 9 3 2 uel LEDS T s 11 3 9 Top view Panel vita a ad uaa n oaa Puis tidad 11 Cableados 12 4 1 Ethernet Cable Sariini e ia a aa a a aa 12 4 1 1 10 100 100BASE TX 10BASE T Pin Assignments eeeeesesssss 12 4 2 SOS Ole 10 te pepe OS o n P Op T NR EE 13 WEB Manage mentido ios 14 5 1 Configuration by Web Browser ooooccccnncccccccoonnccnnnncnnonononccnnnnnnonnnnnnnnnnnnnononanecnnns 14 5 1 1 About Web based Management cccccssesececcesseseececeesseceeeeseaeeeeseeageeeesssaaees 14 5 1 2 System MTOM MANO Riess eemper oo lis 16 99 IRONING naaa a T ct unire dul ce ac Desa NC Copa lee 16 Sm sie cipere cc X a 17 5 1 4 1 A e ouais Coton ema etn ed auus Lon ebbe dirus 17 5 1 4 2 Admin Password cccooccccccoccncconcnnconononcnnnnnnnnnnncnnnnnnncnnnnnrnnnonnnnnnnnanrnnnnnnraninnas 17 om MEM Queer c 18 Olea Time Sell estrellada 19 MAS EUS 23 1 40 MOIDUS TOP M U 23 Seat AUO Provis OM tarta cba 24 Orla Barr S OSI DAA AAN 24 ORing Industrial Networking Corp 2 IES 3240 User s Manual 9 144 9 Upgrade FII WalQisueu nios debeo qoae tao bae ERR or dtes Sees Pear deed 26 SA aio o ENDURO NAE 26 5 1 1 1 A M 26 SRZ OPEN RNO e ierit eo lla lia 27 SS ONO mm 29 5 1 1 4 RSTP Repeater coocccccccconnnncccnonncnncnononn
4. Apply to set the configurations 5 1 10 Monitor and Diag 5 1 10 1 System Event Log If system log client is enabled the system event logs will be shown in this table system Event Log 4 Jan 3 19 35 12 SYSLOG server 92 168 10 66 1 Jan 3 19 25 12 S YS LO Enable Pasel w System event log interface The following table describes the labels in this screen To get the newest event logs and refresh this page ORing Industrial Networking Corp 72 IES 3240 User s Manual 5 1 10 2 MAC Address Table Refer to IEEE 802 1 D Sections 7 9 The MAC Address Table that is Filtering Database supports queries by the Forwarding Process as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port MAC Address Table Port No 4lL v MAC Address Port No Static 001122334455 Port Qo Dynamic 001694988989 Portt 08 Static io05ED00006 Port 05 Dynamic Address Count 1 Static Address Count 2 MAC Address Aging Setting MAC Address Aging Time min w Auto Flush Table When Ports Link Down MAC Address Auto Learning isis MAC Address Table interface The following table describes the labels in this screen Show all MAC addresses mapping to a selected port in table Flush MAC Table Clear all MAC addresses in table MAC Address Aging Assign aging time MUST be multiple of 15 Time Auto Flush Table Enable this f
5. Port 05 Lo TRI LOWES Port 07 Port 08 Port based Priority interface The following table describes the labels in this screen Port base Priority Assign Port with a priority queue 4 priority queues can be assigned High Middle Low and Lowest Apply Click Apply to set the configurations 5 4 5 3 COS 802 1p COS 802 1p COS Port Default Port No COS Port 01 Port 02 Port 03 COS Priority NE Lo d ele dele re Dre Mr Port 04 Port 05 Port 06 High COS 802 1p interface ORing Industrial Networking Corp 52 IES 3240 User s Manual The following table describes the labels in this screen COS 802 1p COS Class Of Service is well known as 802 1p It describes that the output priority of a packet is determined by user priority field in 802 1Q VLAN tag The priority value is supported 0to7 COS value map to 4 priority queues High Middle Low and Lowest COS Port Default When an ingress packet has not VLAN tag a default priority MM value is considered and determined by ingress port Click Apply to set the configurations Hep Show help file 5 1 5 4 TOS DSCP TOS DSCP DSCP 0 1 2 3 4 J 6 Fi DSCP g y 10 11 12 13 14 1 2 Priority 17 20 DSCP 16 13 21 22 23 19 Priority DSCP 24 25 26 27 28 29 30 31 Priority p DSCP 32 33 34 325 36 af 38 39 priority DSCP 40 41 42 43 44 45 46 47 Priority DSCP 48 49 30 51 252 53 54 323 DSCP 36 3 Y I 39 60 61 62 6
6. Port Authorized Mode Reject force this port to be unauthorized Accept force this port to be authorized Authorize the state of this port was determined by the outcome of the 802 1x authentication Disable this port will not participate in 802 1x Apply Click Apply to set the configurations 802 1x Port Authorized Mode Show 802 1x port authorized state 802 1x Port Authorize State Port No Port Authorize State Port 01 Accept Port 02 Port 03 Port 04 802 1x Port Authorize State interface Port 05 Port 06 5 1 8 5 IP Guard IP Guard Port Setting This page allows you to configure port configuration of IP Guard IP Guard is an intelligent and easy use function for IP security It could protect the network from unknown IP the IP not in allowed list attack The illegal IP traffic will be blocked ORing Industrial Networking Corp 65 IES 3240 User s Manual Port No Port 01 Port 02 Port 03 Port 04 IP Guard Port Setting State interface The following table describes the labels in this screen Disable mode function is totally disabled Monitor mode function is disabled but keeps monitor the IP traffic Security mode function is enabled the illegal IP taffic will be blocked Click Apply to set the configurations Show help file IP Guard Allow List IP Guard is an intelligent and easy use function for IP security It could protect the network from unknown IP the IP not i
7. RR One y Static A One svi Static w amie Done w stc w a i One vil Static e N Port 04 Port 05 vei Static w vil Static ww j Port 06 sei Static w j Port 07 sei Static w j Port 08 w ll static e j Port 09 Port 10 w atc xw Port 11 w Static w Port 12 wj static w w ll static e j Port 13 j Port 14 w etate w vi static e j Port 15 sei Static w i Port 16 state w Port 17 ORing Industrial Networking Corp 44 IES 3240 User s Manual 802 3ad LACP Work Ports Group ID Work Ports Trunk1 bl Trunk Trunk6 Trunks Trunks Trunk10 Trunk11 Trunk12 A Port Trunk Setting interface The following table describes the labels in this screen Grp ID Select port to join a trunk group Support static trunk and 802 3ad LACP Work Port Select the number of active ports in dynamic group LACP The default value of works ports is maximum number of the group If the number is not maximum number of ports the other inactive ports in dynamic group will be suspended no traffic Once the active port is broken the suspended port will be active automatically Apply Click Apply to set the configurations ORing Industrial Networking Corp 45 IES 3240 User s Manual Port Trunk Status Port Trunk Status GroupID Trunk Member Type Trunk 1 Trunk 2 Trunk 3 Trunk 4 Trunk 5 RE
8. SVs wiles iim Industrial 24 port managed Ethernet switch with 24x 10 0 QOBase TC System location Switch setting interface The following table describes the labels in this screen System Name Assign the name of switch The maximum length is 64 bytes System Description Display the description of switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization 5 1 4 2 Admin Password Change web management login username and password for the management security issue Admin Password User Name New Password Confirm Password Go Admin Password interface ORing Industrial Networking Corp 17 IES 3240 User s Manual The following table describes the labels in this screen User name Key in the new username The default is admin New Password Key in the new password The default is admin Confirm password Re type the new password Apply Click Apply to activate the configurations 5 1 4 3 IP Setting You can configure the IP Settings and DHCP client function through IP configuration IP Setting DHCP Client Disable IP Address 132 168 10 1 Subnet Mask 255 255 255 0 Gateway 192 168 10 254 DNS1 DNS IP Configuration interface The following table describes the labels in this screen Label Description DHCP Client To enable or disable the DHCP client functi
9. and enable or disable GVRP protocol There are 256 VLAN groups to provide configure Enable 802 1Q VLAN the all ports on the switch belong to default VLAN VID is 1 The default VLAN cannot be deleted GVRP allows automatic VLAN configuration between the switch and nodes If the switch is connected to a device with GVRP enabled you can send a GVRP request by using the VID of a VLAN defined on the switch the switch will automatically add that device to the existing VLAN VLAN Setting VLAN Operation Mode GVRP Mode Disable v Management VLAN ID 0 Port VLAN Setting Port No Link Type PVID Untagged VIDs Tagged VIDs Exi o 1l 0 poros C po VLAN Configuration 802 1Q interface ORing Industrial Networking Corp 47 IES 3240 User s Manual The following table describes the labels in this screen VLAN Operation Mode Configure VLAN Operation Mode disable Port Base 802 1Q GVRP Mode Enable Disable GVRP function Management VLAN ID Management VLAN can provide network administrator a secure VLAN to management Switch Only the devices in the management VLAN can access the switch CA Select the port to configure Link type There are 3 types of link type Access Link single switch only allows you to group ports by setting the same VID Trunk Link extended application of Access Link allows you to group ports by setting the same VID with 2 or more switches Hybrid Link Both Access Link and Trunk Link are availab
10. product s associated with this publication DISCLAIMER Information in this publication is intended to be accurate ORing shall not be responsible for its use or infringements on third parties as a result of its use There may occasionally be unintentional errors on this publication ORing reserves the right to revise the contents of this publication without notice CONTACT INFORMATION ORing Industrial Networking Corp 4F NO 3 Lane235 Baociao Rd Sindian City Taipei County 23145 Taiwan R O C Tel 886 2 2918 3036 Fax 886 2 2918 3084 Website www oring networking com Technical Support E mail Support oring networking com Sales Contact E mail sales oring networking com Headquarters sales oring networking com cn China ORing Industrial Networking Corp 1 IES 3240 User s Manual Table of Content Getting to Know Your Switch eeeeeeeeeeeeeeeeee eene nnne nnn nnn 5 1 1 About the IES 3240 Managed Industrial Switch oooooncccnncccononnnccnnnccnnonnanncnnnnnnos 5 1 2 SOWA e Fedre S econo ateo diosa a OON todas es dgee 5 1 3 Hardware Features pterea deo a exu eua 0A KR Ea vo S HR paa E aUa di 6 Hardware Instalada di 7 2 1 Installing Switch on DIN Rall ooonccncccccncnnccccconcnnncnnnancnnnconononnononannnnnononannnnnonnnancnns 7 2 1 1 Mount IES 3240 SERIES on DIN Rail esee 7 2 2 Wall IVIOUMTING Installato aorin tcp 8 Hardware OVerVIQW
11. workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 1 7 1 SNMP Agent Setting You can set SNMP agent related information by Agent Setting Function SNMP Agent Setting SNMP Agent Version Apply SNMP V1 V2c Community Community String Privilege ee s ees SNMP Agent setting interface The following table describes the labels in this screen SNMP agent Version Three SNMP versions are supported such as SNMP V1 SNMP V2c and SNMP V3 SNMP V1 SNMP V2c agent use a community string match for authentication that means SNMP servers access objects with read only or read write permissions with the community default string public private SNMP V3 requires an authentication level of MD5 or DES to encrypt data to enhance data security SNMP V1 V2c SNMP Community should be set for SNMP V1 V2c Four sets of Community Community String Privilege are supported Each Community otring is maximum 32 characters Keep empty to remove this ORing Industrial Networking Corp 57 IES 3240 User s Manual Apply Click Apply to activate the configurations 5 1 7 2 SNMP Trap Setting A trap manager is a management station that receives traps the system alerts generated by t
12. 1 1 1 O Ring O Ring is the most powerful Ring in the world The recovery time of O Ring is less than 10 mS It can reduce unexpected damage caused by network topology change O Ring supports three Ring topologies O Ring Coupling Ring and Dual Homing O Ring Enable Ring M Enable Ring Master 1st Ring Port LINKDOWN 2nd Ring Port LINKDOWN M Enable Couple Ring Couple Port LINKDOWN M Enable Dual Homing Homing Port LINKDOWN O Ring interface ORing Industrial Networking Corp 26 IES 3240 User s Manual The following table describes the labels in this screen Enable Ring Mark to enable Ring Enable Ring Master There should be one and only one Ring Master in a ring However if there are two or more switches which set Ring Master to enable the switch with the lowest MAC address will be the actual Ring Master and others will be Backup Masters 1 Ring Port The primary port when this switch is Ring Master 2 Ring Port The backup port when this switch is Ring Master Enable Coupling Ring Mark to enable Coupling Ring Coupling Ring can be used to divide a big ring into two smaller rings to avoid effecting all switches when network topology change It is a good application for connecting two Rings Coupling Port Link to Coupling Port of the switch in another ring Coupling Ring need four switch to build an active and a backup link Set a port as coupling port The coupled four ports of four switche
13. 21 Port 22 Port 23 Port 24 iss System Warning SYSLOG Setting The SYSLOGi is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol SYSLOG Setting Syslog Mode ei oe 192 168 10 55 System Warning SYSLOG Setting interface The following table describes the labels in this screen SYSLOG Mode B Disable disable SYSLOG B Client Only log to local system B Server Only log to a remote SYSLOG server ORing Industrial Networking Corp 69 IES 3240 User s Manual BEEN B Both log to both of local and remote server SYSLOG Server IP The remote SYSLOG Server IP address Address Apply Click Apply to set the configurations System Warning SMTP Setting The SMTP is Short for Simple Mail Transfer Protocol Itis a protocol for e mail transmission across the Internet Please refer to RFC 821 Simple Mail Transfer Protocol SMTP Setting E mail Alert Enable SMTP Server IP Address 132 1658 10 66 Mail Subject Automated Email Alert Sender test mail E Authentication Rcpt e mail Address 1 Rcpt e mail Address 2 Rcpt e mail Address 3 Rcpt e mail Address 4 System Warning SMTP Setting interface The following table describes the labels in this screen EmaiMan ErabeDsblevaremisson system warning events by ema Sender Set up the email account to send the alert Authentication m Username the authenti
14. Console 9600 8 none 1 none Before Configuring by RS 232 serial console use an RJ45 to DB9 F cable to connect the Switches RS 232 Console port to your PCs COM port Follow the steps below to access the console via RS 232 serial cable Step 1 From the Windows desktop click on Start gt Programs gt Accessories gt Communications gt Hyper Terminal Accessibility En Communications al HyperTerminal a Network Time Protocol E Network and Dial up Connections System Tools gt HyperTerminal E Acrobat Reader 5 0 ia Address Book E3 Calculator EN command Prompt C NetTime F Notepad Windows Update Y Paint a EN windows Explorer I Accessories Network Associates F 1 Documents ae Startup L 8 Internet Explorer al Outlook Express Search 3 Programs 3 Settings d ster e d d I ORing Industrial Networking Corp 81 Step 2 Input a name for new connection Connection Description i 7 x ai Mew Connection Enter a name and choose an icon far the connection M ame cor Disconnected Auto detect Auto detect SCROLL caps NUM Capture Print echo otep 3 Select to use COM port number z termnial HyperTerminal File Edi View Call Transfer Help Comectro 21 md 24 termeial Enter details for the phone number that you want to dial Country region Taiwan 885 Area code 3 Phone number EAN Connect using m Cancel Disconnected Auto detect Au
15. Power Indicator Green Power LED x 3 R M Indicator Green Indicate system operated in O Ring master mode ORing Industrial Networking Corp 106 IES 3240 User s Manual ORing Industrial Networking Corp 107
16. Priority 0 61440 A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root If the value changes You must reboot the switch The value must be multiple of 4096 according to the protocol standard rule Max Age Time 6 40 The number of seconds a bridge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 The setting follow the rule below to configure the MAX Age Hello ORing Industrial Networking Corp 35 IES 3240 User s Manual Time and Forward Delay Time at controlled switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 2 x Forward Delay Time value 1 2 Max Age value 2 2 x Hello Time value 1 Forwarding Delay The number of seconds a port waits before changing from its Time 4 30 Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Max Hops 1 40 This parameter is additional to those specified for RSTP A single value applies to all Spanning Trees within an MST Region the CIST and all MSTIs for which the Bridge is the Regional Root Apply Click Apply to activate the configurations MSTP Bridge Port Path Cost 1 200000000 O Auto Admin Admin Admin P2P Edge Non Stp Priority 0 240 priority must be a mu
17. Protocol function allows the switch to advertise its information to other nodes on the network and store the information it discovers LLDP LLDP Protocol Enable iv LLDP Interval Neighbor Info Table Port System Name MAC Address IP Address ieee IGS5 3044GC 00 1E 94 34 04 B0 102 168 10 20 LLDP configuration interface The following table describes the labels in this screen LLDP Protocol Enable or Disable LLDP function LLDP Interval The interval of resend LLDP by default at 30 seconds Apply Click Apply to set the configurations Show help file Neighbor info table Can show neighbor device info 5 1 4 6 Modbus TCP Support Modbus TCP About Modbus please reference http www modbus org Modbus TCP Mode Enable The following table describes the labels in this screen Mode Enable or Disalble Modbus TCP function ORing Industrial Networking Corp 23 IES 3240 User s Manual 5 1 4 7 Auto Provision Auto Provision allows you to update the switch firmware automatically You can put firmware or configuration file on TFTP server When you reboot the switch it will upgrade automatically Before updating make sure you have your TFTP server ready and the firmware image and configuration file is on the TFTP server Auto Provision L Auto install configuration file from TFTP server MS ATT A 1192 165 10 66 Configuration File Name L Auto install firmware image file from
18. be a multiple of 16 ORing Industrial Networking Corp 32 Port Status Port Path Port Cost Priority P2P Edge Neighbor Port 01 200000 Port 02 200000 IES 3240 User s Manual Oper Oper stp State Role False Disabled Disabled Disabled Disabled False Disabled Disabled False Disabled Disabled Port 05 200000 Path Cost 1 200000000 Port Priority 0 240 Admin P2P Admin Edge Admin Non STP False Disabled Disabled Description The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means P2P enabling False means P2P disabling The port directly connected to end stations and it cannot create bridging loop in the network To configure the port as an edge port set the port to True The port includes the STP mathematic calculation True is not including STP mathematic calculation False is
19. command set oooccccccccnccccccccnnccnnannnnnnnnnnnnnnnononinnnnnos 91 6 5 Commands Set List VLAN command set ssseessses 92 6 6 Commands Set List Spanning Tree command set seeeesssss 93 6 7 Commands Set List QoS command set esses 96 6 8 Commands Set List IGMP command St ooocccccnccnncccccccnnnncnnnnnnccnnnnnnnnncncnnnnnnnns 96 6 9 Commands Set List MAC Filter Table command set 97 6 10 Commands Set List SNMP command S t oooocccnnncccccccnccnnnnccnononannnonnncnnnnnnnos 97 6 11 Commands Set List Port Mirroring command set sseeeeessss 99 6 12 Commands Set List 802 1x command set oooonnncnnnccccccnoncnnnnncnnnnnnanononcnnnnnnnos 99 6 13 Commands Set List TFTP command set cccccseeeeeeeeeeeeeeaeeseeeeeeeseuaeeeees 101 6 14 Commands Set List SYSLOG SMTP EVENT command set 102 6 15 Commands Set List SNTP command S6t oooonnnnnnncccccnonncnnnnccnononancconcnnnnnanos 104 6 16 Commands Set List O Ring command S t ooocccnnnccccccccnnccnnnnonnnnnnnnnnnnnnnnnnnans 105 Technical Specifications iii 106 ORing Industrial Networking Corp 4 IES 3240 User s Manual Getting to Know Your Switch 1 1 About the IES 3240 Managed Industrial Switch The IES 3240 series are powerful managed industrial switches with many features These sw
20. compatibility and cost effectiveness in one set of network redundancy topologies O Chain allows multiple redundant network rings of different redundancy protocols to join and function together as a larger and more robust compound network topology i e the creation of multiple redundant networks beyond the limitations of current redundant ring technology O Chain Uplink Port Edge Port State LE Fooly Do uno zu Pe v O Forwarding Apply Enable Erabing tne O infame Edge Port In the O Chain application the head and tail of two Switch Port must start the Edge MAC smaller Switch Edge port will be the backup and RM LED Light Edae Port Edqe Port Edae Port Edge Port O Chain ORing Industrial Networking Corp 29 IES 3240 User s Manual 5 1 1 4 RSTP Repeater RSTP Repeater is a simple function this function can direct pass RSTP BPDU packet like two RSTP devices connected RSTP Repeater M Enable Uplink Port RSTP Edge Port Enable Check this box to enable RSTP Repeater 1 Ring Port Choosing the port which connect to the RSTP 2 Ring Port Choosing the port which connect to the RSTP Edge Port Only the edge device connected to RSTP device needs to specify edge port The user must specify the edge port according to topology of network 5 1 1 5 Fast Recovery The Fast Recovery Mode can be set to connect multiple ports to one or more switches The TES 250 M12 with its fas
21. for IP security It could protect the network from unknown IP the IP not in allowed list attack The illegal IP traffic will be blocked IP Guard Monitor List Add to Allow List O 192 168 10 66 001E94988989 Port 08 19700103 19 20 The following table describes the labels in this screen Port number of entry Time Time he The logged time time Add to Allow List Nolo osi RN you want to allow the IP traffic please check this box and apply it 9 1 9 Warning Warning function is very important for managing switch You can manage switch by SYSLOG E MAIL and Fault Relay It helps you to monitor the switch status on remote site When events occurred the warning message will send to your appointed server E MAIL or relay fault to switch panel System alarm support two warning mode 1 SYSLOG 2 E MAIL You can monitor switch through selected system events Warning Fault Relay Alarm When any selected fault event is happened the Fault LED in switch panel will light up and the electric relay will signal at the same time ORing Industrial Networking Corp 68 IES 3240 User s Manual Fault Relay Alarm Power Failure PWR 1 PWR 2 Port Link Down Broken Port 01 Port 02 Port 03 Port 04 Port 05 Port 06 Port 07 Port 08 Port 09 Port 10 Port 11 Port 12 Port 13 Port 14 Port 15 Port 16 Port 17 Port 18 Port 19 Port 20 Port
22. including the STP mathematic calculation Apply Click Apply to set the configurations ORing Industrial Networking Corp 33 IES 3240 User s Manual 5 1 1 7 MSTP Multiple Spanning Tree Protocol MSTP is a standard protocol base on IEEE 802 1s The function is that several VLANs can be mapping to a reduced number of spanning tree instances because most networks do not need more than a few logical topologies It supports load balancing scheme and the CPU is sparer than PVST Cisco proprietary technology IES 3080 IGS 3044GP RES 3242GC E VLAN 100 VLAN 200 ORing Industrial Networking Corp 34 IES 3240 User s Manual MSTP Bridge Setting MSTP Enable Force Version Configuration Name Revision Level 0 65535 Priority 0 61440 Max Age Time 6 40 Hello Time 1 10 Forward Delay Time 4 30 Max Hops 1 40 Priority must be a multiple of 4096 2 Forward Delay Time 1 should be greater than or equal to the Max Age The Max Age should be greater than or equal to 2 Hello Time 1 Apply MSTP Setting interface The following table describes the labels in this screen MSTP Enable You must enable or disable MSTP function before configuring the Hp RM Force Version The Force Version parameter can be used to force a VLAN Bridge re AA Configuration Name The same MST Region must have the same MST configuration manm ni nbn Revision Level The same MST Region must have the same revision level cag
23. ip binding ponieg c nn ORing Industrial Networking Corp 87 IES 3240 User s Manual no dhcpserver Disable DHCP server switch config no dhcpserver m i dmi md security enable Enable IP security switch config security enable morem security http Enable IP security of switch config security http m ommum security telnet Enable IP security of jswitch config security telnet A a security ip Index 1 10 IP Address Set the IP security list switch config security ip 1 192 168 1 55 show security Show the information switch show security INN ud EN no security Disable IP security switch config no security rm oem no security http Disable IP security of switch config zino security http d eme m no security telnet Disable IP security of telnet server switch config zzno security telnet 6 3 Commands Set ei ami Commands Set Choose the port for modification interface fastEthernet Portid i Use the duplex configuration command to specify the duplex mode of operation for Fast Ethernet speed 10 100 1000 auto Use the speed configuration command to specify the speed mode of operation for Fast switch config interface fastEthernet 2 switch config interface fastEthernet 2 switch config if duplex full switch config interface fastEthernet 2 switch config if speed 100 ORing Industrial Networking Corp 88 flowcontrol mode Symmetric Asymmetric bandwidth type broa
24. 3 TOS DSCP interface The following table describes the labels in this screen TOS DSCP TOS Type of Service is a field in IP header of a packet This TOS field is also used by Differentiated Services and is called the Differentiated Services Code Point DSCP The output priority of a packet can be determined by this field and the priority value is supported Oto63 DSCP value map to 4 priority queues High Middle Low and Lowest Apply Click Apply to set the configurations ORing Industrial Networking Corp 53 IES 3240 User s Manual 5 1 6 DHCP Server 5 1 6 1 DHCP Server Setting The system provides with DHCP server function Enable the DHCP server function the switch system will be a DHCP server DHCP Server Basic Setting DHCP Server Disable w Low IP Address 192 168 10 2 aR Ug 192 166 10 200 Subnet Mask 255 255 255 0 Gateway 192 168 10 254 Lease Time sec DHCP Server Configuration interface The following table describes the labels in this screen DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network Start IP Address The dynamic IP assign range Low IP address is the beginning of the dynamic IP assigns range For example dynamic IP assign range is from 192 168 1 100 to 192 168 1 200 192 168 1 100 will be the Start IP address End IP Address The dynamic IP assign range High IP address is the end of the dynami
25. 32 cable with DB 9 female connector and the other end RJ 45 connector connects to console port of switch PC pin out male assignment DB Male Shield E DB Female IA As Received Line Signal Detect 5 a7 Ring Indicator 3 c a DCE Ready DTE Ready mp 4 Trams mitted Data agg g Clear to Send j Clear to Send Transmitted Data Received Data 3 Pe Request to Ser Received Data 2 DTE Ready 4 SP Request to Send h Ring Indicator Received Line Signal Detect DCE Ready Signal Ground aes 9 il Received by D TE Device eal Received by DCE Device 9 We Transmitted from DTE Device 4 42 Transmitted from DCE Device ORing Industrial Networking Corp 13 IES 3240 User s Manual WEB Management While making any establishment and upgrading firmware please remove physical loop connection first DO NOT power off equipment during firmware is upgrading 5 1 Configuration by Web Browser This section introduces the configuration by Web browser 5 1 1 About Web based Management An embedded HTML web site resides in flash memory on the CPU board It contains advanced management features and allows you to manage the switch from anywhere on the network through a standard web browser such as Microsoft Internet Explorer The Web Based Management function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth co
26. 6 16 Commands et List O Ring command set SE RT Ringenabe erase ORing omhoog rg eae xd master G Enable ring master T ring master Ring couplering Enable couplerng wichconfebingcounermo Ring duahoming 6 Enable dual homing _owithconfg ing uahoring Ring ringport switch config ring ringport 7 8 1st Ring Port 2nd Ring Port Ring couplingport i i switch config ring couplingport 1 Coupling Port Ring controlport Configure Control Portiswitch config ring controlport 2 SN n RR Ring homingport Configure Dual switch config ring homingport 3 pame mmm Show the information switch show ring INNEN poRing Disable O Ring switch swith config no ing ring no Ring master G Disable ring master switch config no ring master no Ring couplering G Disable couple ring switch config no ring couplering no Ring dualhoming G Disable dual homing switch config no ring dualhoming ORing Industrial Networking Corp 105 IES 3240 User s Manual Technical Specifications Fault Indicator Amber Indicate unexpected event occurred reen for port Link Act Amber for Duplex Co 565 3240 A T ee A A A AAA S a Fault contact Re a00 Base T X Ports in RJ 45 Relay output to carry capacity of 1A at 24VDC Power LI VStlilnivivuyy Power consumption ENT PEG BABOR 3u for 100Base TX Overload current p
27. Cojo O Coo Port monitoring interface ORing Industrial Networking Corp 77 IES 3240 User s Manual The following table describes the labels in this screen Destination Port The port will receive a copied frame from source port for inl NN Source Port The port will be monitored Mark the blank of TX or RX to be mem mx Wefameneebysbhpat Click Apply to activate the configurations AE 5 1 10 6 Traffic Monitor The function can monitor switch Traffic If traffic is too large Switch will sent SYSLOG Event or SMTP Mail Time Interval 173005 T isable sai System event log interface Monitored Counter Increasing Quantity The following table describes the labels in this screen Monitored Counter Select monitor type Time Interval Setting Interval time Increasing Quantity Setting alarm Quantity Event Alarm Select alarm function SYSLOG or SMTP ORing Industrial Networking Corp 78 IES 3240 User s Manual 5 1 10 7 Ping Ping function allows the switch to send ICMP packets to detect the remote notes Ping IP Address 192 158 1066 Ping Log Pinging 192 168 10 66 seq 1 sent Reply seq 1 from 192 168 10 66 Pinging 192 168 10 66 seq 2 sent Reply seq 2 from 192 168 10 66 Pinging 192 168 10 66 seq 3 sent Reply seq 3 from 192 168 10 66 Pinging 192 168 10 66 seq 4 sent Reply seq 4 from 192 168 10 66 Ping complete sent 4 received 4 Ping interface The
28. IaG1 G2 IP Address Member Ports 230 0 0 6 Port 04 Port 05 Multicast Filtering Interface The following table describes the labels in this screen IP Address Assign a multicast group IP address in the range of 224 0 0 0 239 255 255 255 Member Ports Tick the check box beside the port number to include them as the member ports in the specific multicast group IP address Add Show current IP multicast list Delete Delete an entry from table ORing Industrial Networking Corp 4 IES 3240 User s Manual 5 1 3 Port Setting 5 1 3 1 Port Control By this function you can set the state speed duplex flow control and security of the port Port Control Port No State Speed Duplex Flow Control Security Port 01 Port 02 Port 03 Port 04 Port Control interface The following table describes the labels in this screen Port NO Port number for setting State Enable Disable the port Speed Duplex You can set Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Security Enabled port security will disable MAC address learning in this port Thus only the frames with MAC addresses in port security list will be forwarded otherwise will be discarded Auto Detect 100 1000 Auto Detect SFP port SFP Module speed 100M 1000M Apply Click Apply to activate the configurations ORing Industrial Net
29. N ID Member Port 230 0 0 20 Port 07 IGMP Snooping interface The following table describes the labels in this screen IGMP Snooping Table Show current IP multicast list IGMP Protocol Enable Disable IGMP snooping IGMP Query Switch will be IGMP querier or not There should exist one and only one IGMP querier in an IGMP application The Auto mode means that the querier is the one with lower IP address Apply Click Apply to set the configurations ORing Industrial Networking Corp 39 IES 3240 User s Manual 5 1 2 2 MVR MVR Function can provide a different VLAN users to receive MVR Mode VLAN Multicast Packet MVR MVR Mode Disable v MVR VLAN Type Immediate Leave o Doo Inactive e xw IVE Label MVR Mode Enable or Disable MVR Mode MVR VLAN Setting MVR VLAN TYPE Setting Port Type to inactive Receiver gt Source Immediate Leave Enable or disable Immediate leave ORing Industrial Networking Corp 40 IES 3240 User s Manual 5 1 2 3 Static Multicast Filtering otatic Multicast filtering is the system by which end stations only receive multicast traffic if they register to join specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to registered end stations Static Multicast Filtering Multicast IP Address NEN Member Ports Port 01 Port 02 Port 03 Port 04 Port 05 Port 06 Port 07 Port 08
30. Ring Industrial Networking Corp 96 IES 3240 User s Manual LL AR LL no igmp query G Disable IGMP query switchzino igmp query 69 Commands Set List MAC Filter Table command set les 3240 Commands Lovel Deseription ambe mac address table static Configure MAC switch config interface fastEthernet hwaddr address table of 2 MAC interface static switch config if mac address table static hwaddr 000012345678 mac address table filter Configure MAC switch config mac address table hwaddr address table filter filter hwaddr 000012348678 MAC show mac address table Show all MAC switch show mac address table E pem show mac address table Show static MAC switch show mac address table show mac address table Show filter MAC switch show mac address table filter no mac address table Remove an entry of switch config interface fastEthernet static hwaddr MAC address table of 2 MAC interface static switch config if no mac address table static hwaddr 000012345678 no mac address table Remove an entry of switch config no mac address table MAC address table filter hwaddr 000012348678 filter no mac address table Remove dynamic switch config no mac address table entry of MAC address table 6 10 Commands Set List SNMP command set G Select the agent mode switch config snmp agent mode viv2c ORing Industrial Networking Corp 97 IES 3240 User s Manual snmp server host i switch config snmp se
31. Static Port Trunk Status interface Group Key Trunk Group number Port Member Show Group port info 5 1 3 6 Loop Guard This feature prevents the loop attack When the port receives loop packet This port will auto disable prevent the loop attack affect other network devices Loop Guard Port No Active Port State Port 01 La Enable Port 02 HH v Enable Port 03 Ho Enable Active Loop Guard Enable or Disable Port Status Port work status ORing Industrial Networking Corp 46 IES 3240 User s Manual 5 1 4 VLAN A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which allows you to isolate network traffic Only the members of the VLAN will receive traffic from the same members of VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically The switch supports port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is at 802 1Q 5 1 4 1 VLAN Setting IEEE 802 1Q Tagged based VLAN is an IEEE 802 1Q specification standard and t is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers You can create Tag based VLAN
32. TFTP server Mi 192 168 10 66 Firmware File Name Apply Help Auto Provision interface 5 1 4 8 Backup 8 Restore You can save current EEPROM value from the switch to TFTP server then go to the TFTP restore configuration page to restore the EEPROM value Restore Configuration From TFTP Server TEIP Server IP Address 1 168 102 Restore File Name data bin From Local PC iow ORing Industrial Networking Corp 24 IES 3240 User s Manual Backup Configuration To TFTP Server TFTP Server IP Address ES ae Backup File Name To Local PC Backup Backup amp Restore interface The following table describes the labels in this screen Fill in the TFTP server IP Fill the file name Click restore to restore the configurations User can select file restore not need TFTP server Restore File Name Fill the file name Click restore to restore the configurations Click backup to backup the configurations To Local PC User can download config file to switch not need TFTP server ORing Industrial Networking Corp 29 IES 3240 User s Manual 5 1 4 9 Upgrade Firmware Upgrade Firmware allows you to update the switch firmware Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server Upgrade Firmware From TFTP Server TFTP Server IP 152 158 102 Firmware File Name From Local PC Update Firmware interface 5 1 1 Redundancy 5
33. c IP assigns range For example dynamic IP assign range is from 192 168 1 100 to 192 168 1 200 192 168 1 200 will be the End IP address Subnet Mask The dynamic IP assign range subnet mask The gateway in your network DNS Domain Name Server IP Address in your network Lease Time It is the period that system will reset the assigned dynamic IP to ensure Hour the IP address is in used Apply Click Apply to set the configurations ORing Industrial Networking Corp 54 IES 3240 User s Manual 5 1 6 2 DHCP Server Client List When the DHCP server function is activated the system will collect the DHCP client information and display in here DHCP Server Client List DHCP Server Client Entries interface 5 1 6 3 DHCP Server Port and IP bindings You can assign the specific IP address which is in the assigned dynamic IP range to the specific port When the device is connecting to the port and asks for dynamic IP assigning the system will assign the IP address that has been assigned before in the connected device DHCP Server Port and IP Binding Port emi 132 166 10 123 IA 0000 Port 03 0000 Port 04 000 0 Port 05 0 0 0 0 DHCP Server Port and IP Binding interface 5 1 6 4 DHCP Server DHCP Relay Agent The DHCP relay agent relays DHCP messages between clients and servers for DHCP on different subnet domain DHCP relay agent use Option 82 to insert specific information into a request that is being forwarde
34. cation username B Password the authentication password B Confirm Password re enter password ORing Industrial Networking Corp 70 IES 3240 User s Manual Recipient E mail Address The recipient s E mail address It supports 6 recipients for a mail Apply Click Apply to set the configurations System Warning Event Selection SYSLOG and SMTP are the two warning methods that supported by the system Check the corresponding box to enable system event warning method you wish to choose Please note that the checkbox can not be checked when SYSLOG or SMTP is disabled Event Selection System Event Event Type Device cold start Device warm start Syslog 0 Jm ENS Authentication failure O Ring topology change Port Event Port Port 01 Port 02 Syslog Link Down Disable Disable Link Up amp Link Down System Warning Event Selection interface The following table describes the labels in this screen Device cold start When the device executes cold start the system will issue a log event Device warm start When the device executes warm start the system will issue a log event Authentication Failure Alert when SNMP authentication failure O Ring topology change Alert when O Ring topology changes Port Event B Disable B Link Up ORing Industrial Networking Corp 71 IES 3240 User s Manual E Link Down B Link Up amp Link Down Apply Click
35. cludes 2 Ground wire ORing Industrial Networking Corp 11 IES 3240 User s Manual Cables 4 1 Ethernet Cables The IES 3240 switches have standard Ethernet ports According to the link type the switches use CAT 3 4 5 5e UTP cables to connect to any other network device PCs servers switches routers or hubs Please refer to the following table for cable specifications Cable Types and Specifications 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 4 1 1 10 100 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data RJ 45 Pin Assignments O tas ORing Industrial Networking Corp 12 IES 3240 User s Manual The IES 3240 switches support auto MDI MDI X operation You can use a straight through cable to connect PC to switch The following table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs 10 100 Base TX MDI MDI X pins assignment TD transmit RD receive TD transmit RD receive RD receive TD transmit i RD receive TD transmit 8 MumP ets Note and signs represent the polarity of the wires that make up each wire pair 4 2 Console Cable IES 3240 switches can be management by console port The DB 9 to RJ 45 cable can be found in the package You can connect them to PC via a RS 2
36. cnnnnononnnnnnnnnnnnnnnnnonnnnnnnnnnnnrnnnnnnnannons 30 5 1 1 5 JRaSUROCOVOLV dai 30 ERRO ic HE iced ele Tit codem DOM ee 31 SELA Iu A 34 Ode A A as aec bL L Ute Duo nasi 39 5 1 2 1 IGMP SMOC DING eem er cm 39 on MEM UU ORT 40 5 52 9 St uc Multicast PINGHING uoa eate uei oil E tete poen tuos 41 A elei M T LIT Tn 42 5 1 3 1 A 9 g poter cp IE 42 Dele POM SIUS editioni at ici ie uin edes vate Docet tu ub DE Ce ueni Mast tu S Moe Ca UIDI 43 E o AA Ue o O E s ed bna puris 43 o A A AN 43 E A O A Md UR 44 E LOOP CUA reini aena ne eed eiat une odori ole Renee doas 46 ruv 47 5 1 4 1 VLAN Setting IEEE 802 1Q occcccccccccccccccccnonnnnccnnnnnnnnonnnononononnnnonnnnnnnnnnnns 47 5 1 4 2 VLAN Setting Port Based ccccccccncccccccooconncccnnonnnnnnonannnnnnononnnnnnnnunanoss 48 Dala LPAI IPMONMUZ AMON reete e US 51 5 1 5 1 Merger E MM 51 5 1 5 2 Port base priority sessi nnns 52 cn ocu e S c lm mem 52 NEST MENO SUD SSR e ER 53 O TOO DEEP 54 5 1 6 1 DHCP Server Setting ccccccocconnccnnncccccnnonnncnnnnnnnonannnnnnnnnonnnnnnnnnnnnnnnnnnnnos 54 5162 DACP Server Client stud or PER 55 5 1 6 3 DHCP Server Port and IP bindings Swennen aa 55 5 1 6 4 DHCP Server DHCP Relay Agent ccccccccsssseeeeeeeeeessaeseeseeeeseaaeeeees 55 Sur SN om tct M E E Lu mL EE 57 5 1 7 1 SNMP Agent Seta eonim ee e
37. config smtp account User authentication account smtp password Configure switch config smtp password password authentication password smtp rcptemail Configure Rcpt e mail switch config smtp rcptemail 1 Index Email address Address Alert test com ORing Industrial Networking Corp 102 IES 3240 User s Manual Show the information switchzzshow smtp INN EMEN Disable SMTP switch config no smtp BEEN SN event device cold start Set cold start event switch config tevent Systemlog SMTP Both Ei both event Set Authentication switch config event authentication failure failure event type authentication failure both Systemlog SMTP Both event Set s ring topology switch config event O Ring topology change changed event type ring topology change both Systemlog SMTP Both event systemlog Set port event for switch config interface fastethernet Link UP Link Down Bot system log 3 h switch config if tevent systemlog both event smtp Set port event for switch config interface fastethernet neo SMTP 3 oo if tevent smtp both showevent P Show event selection swihfshowewn no event Disable cold start switch config no event device cold start EL device cold start no event Disable Authentication switch pom no event no event Disable O Ring switch config no event O Ring topology change topology changed ring topology change event type no event systemlog Disable port event for switch config i
38. cp no ip dhcp function of switch reload Halt and perform a switch config reload cold restart Restore to default Switch config default Changes a login switch config admin username admin username username XXXXXX Username maximum 10 words Specifies a password switch config admin password Show administrator switchzzshow admin Enable DHCP Server switch config dhcpserver enable Configure low IP switch config dhcpserver lowip address for IP pool 192 168 1 1 Configure high IP switch config dhcpserver highip admin password Password dhcpserver enable dhcpserver lowip Low IP dhcpserver highip High IP address for IP pool 192 168 1 50 dhcpserver subnetmask Configure subnet switch config dhcpserver acres cena subnetmask 255 255 255 0 dhcpserver gateway Configure gateway for switch config dhcpserver gateway carn d M dhcpserver dnsip Configure DNS IP for switch config dhcpserver dnsip dhcpserver leasetime Configure lease time switch config dhcpserver eumd ld d NN dhcpserver ipbinding Set static IP for DHCP switch config ztinterface IP address clients by port fastEthernet 2 switch config if dhcpserver ipbinding 192 168 1 1 show dhcpserver Show configuration of switchzzshow dhcpserver vocal adco NN show dhcpserver clients Show client entries of switch show dhcpserver clinets ie ied show dhcpserver Show IP Binding switch show dhcpserver
39. d to a DHCP server and according to Option 82 to remove the specific information from a reply packets when forwarding server DHCP packets to a DHCP client ORing Industrial Networking Corp 55 IES 3240 User s Manual DHCP Relay Agent Mode Enable DHCP Server IP Address 1st Server IP 2nd Server IP 3rd Server IP Ath Server IP Type Value Display AA SUA DHCP Option 82 Circuit ID Table Port No Circuit ID Option 82 Port 01 000400010000 oO Port 02 000400010002 Port 03 0004000100053 Port 04 000400010000 Port 05 0004000010005 Port 06 000400010006 The following table describes the labels in this screen DHCP Relay Enable Disable DHCP Relay Agent DHCP Server IP opecify the IP address and VID of DHCP server Keep 0 0 0 0 means Address and VID Server is inactive DHCP Option 82 Option 82 Remote ID provides a identifier for the remote server Remote ID There are 4 types supported IP MAC Client ID and Other DHCP Option 82 Option 82 Circuit ID encodes an agent local identifier of the circuit Circuit ID Table from which a DHCP client to server packet was received It is intended for use by agents in relaying DHCP responses back to the proper Circuit Apply Click Apply to set the configurations ORing Industrial Networking Corp 56 IES 3240 User s Manual 5 1 7 SNMP Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers
40. dcast multicast floo ded unicast bandwidth type broadcast multicast broadcast only bandwidth in Value ORing Industrial Networking Corp IES 3240 User s Manual Ethernet the speed can t be set to 1000 if Use the flowcontrol switch config ztinterface configuration fastEthernet 2 command on Ethernet switch config if flowcontrol mode ports to control traffic Asymmetric rates during Enable security of switch config interface interface fastEthernet 2 switch config if security enable Disable security of switch config interface interface fastEthernet 2 switch config if no security Set interface ingress switch config interface limit frame type to fastEthernet 2 accept all frame switch config if bandwidth type all Set interface ingress switch config interface limit frame type to fastEthernet 2 accept broadcast switch config if bandwidth type multicast and flooded broadcast multicast flooded unicast unicast frame Set interface ingress switch config interface limit frame type to fastEthernet 2 accept broadcast and switch config if fbandwidth type multicast frame broadcast multicast Set interface ingress switch config interface limit frame type to fastEthernet 2 only accept switch contig if bandwidth type broadcast frame broadcast only Set interface input switch config interface bandwidth Rate fastEthernet 2 Range is from 100 switch config if band
41. e ae 57 O 1 2 SNMP Trap Setting uiii dd but esee oet eoe ole 58 SNC MERC UNT 59 ORing Industrial Networking Corp 3 IES 3240 User s Manual An c t 61 5 1 8 1 Management Security cccncccccccconnnccnnconononanncnnnnnnnnnonanncnnnnnononnnnnnnnnonnnnnanos 61 54 92 auc MAG FOMVaIdiING o tese E Eoque te a ee 61 Ole IMAC BIGCKIIST c orit coi ie dee teorie et teer leo eae 62 5 1 8 4 o0 Renee ee ee A e E On ee nen eee ere ee TENE 63 Ue MCG Oe eL 65 94 9 WAN taa do 68 5 1 10 Monitor ana Diadora 72 15101 System Event EOQ isa 72 5 1 10 2 MAC Address Table esses nnne nnns 73 SOS PONOVNI W cnx si se tope o ade 74 SOA A 75 SAO POM VIOMMOUING conecto ci cool 77 SIN EE Cedo H 78 STO TUNG osre etree ae vic red av bbc al oceania aa tua Aa mondo vadis e amide nates 79 5 1 11 Save CONNOUIATIO Ma M este pc 79 5 1 12 Factory Delali m nae 80 5 1 13 System Reboot cccccceccccesseeeeeesecsscceeseceeectsccouseesecesecseccdenseeeeesssacesseeseeseses 80 Command Line Interface Management 81 6 1 About CLI Management sseeseesssssesseeeeeeene nennen nnne nnn nnn 81 6 2 Commands Set List System Commands Set ccccccccssseeeeeeeeseeceesseeeeeees 86 6 3 Commands Set List Port Commands Set cccccccseeeeeeeeeeeeeaeeeeeeeeeeeeeeaeeees 88 6 4 Commands Set List Trunk
42. er The sum of InGoodOctetsLo lengths of all good Ethernet frames received that is frames that are not bad frames The upper 32 bits of the 64 bit InGoodOctets counter The sum of InGoodOctetsHi lengths of all good Ethernet frames received that is frames that are not bad frames InBadOctets The sum of lengths of all bad Ethernet frames received The number of frames transmitted with a invalid FCS Whenever a frame is modified during transmission e g to add or remove a OutFCSErr tag the frames s original FCS is inspected before a new FCS is added to a modified frame If the original FCS is invalid the new FCS is made invalid too and this counter is incremented The number of good frames received that have a Unicast ME destination MAC address The total number of successfully transmitted frames that Deferred experienced no collisions bu are delayed because the medium was busy during the first attempt This counter is applicable in ORing Industrial Networking Corp 75 IES 3240 User s Manual hal ad only 0 000 only The number of good frames received that have a Broadcast InBroadcasts destination MAC address The number of good frames received that have a Multicast destnation MAC address Total frames received and or transmitted with a length of exactly Octets64 64 octes include those with errors Total frames received and or transmitted with a length of Octets127 EM between 65 and 127 octes in clusive includ
43. following table describes the labels in this screen IP Address Enter the IP address that you want to detect Active Click Active to send ICMP packets 5 1 11 Save Configuration If any configuration changed Save Configuration should be clicked to save current configuration data to the permanent flash memory Otherwise the current configuration will be lost when power off or system reset Save Configuration System Configuration interface ORing Industrial Networking Corp 79 IES 3240 User s Manual The following table describes the labels in this screen Save all configurations 5 1 12 Factory Default Factory Default Keep current IP address setting Keep current username amp password Factory Default interface Reset switch to default configuration Click Reset to reset all configurations to the default value You can select Keep current IP address setting and Keep current username amp password to keep current IP and username and password 5 1 13 System Reboot System Reboot Boot from o image bank 0 k3 04 v1 00 built at May 21 2012 13 54 14 image bank 1 empty Reboot Mey System Reboot interface ORing Industrial Networking Corp 80 IES 3240 User s Manual Command Line Interface Management 6 1 About CLI Management Besides WEB base management IES 3240 also supports CLI management You can use console or telnet to management switch by CLI CLI Management by RS 232 Serial
44. g Humidity 596 to 9596 non condensing Casing IP 30 10 100Base T X Ethernet port Console Port Dimensions W x D x H 96 mm W x 109 2 mm D x 153 6 mm H ORing Industrial Networking Corp Hardware Installation 2 1 Installing Switch on DIN Rail Each switch has a DIN Rail kit on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DIN Rail 2 1 1 Mount IES 3240 SERIES on DIN Rail 1000 Win 33 0 DIN Rail Size ORing Industrial Networking Corp 7 IES 3240 User s Manual 2 2 Wall Mounting Installation Each switch has another installation method for users to fix the switch A wall mount panel can be found in the package The following steps show how to mount the switch on the wall Wall Mounting size ORing Industrial Networking Corp 8 Hardware Overview 3 1 Front Panel The following table describes the labels that stick on the IES 3240 Port Description 10 100 RJ 45 fast 8 10 100Base T X RJ 45 fast Ethernet ports support Ethernet ports auto negotiation Default Setting Speed auto Duplex auto Flow control disable Gigabit RJ 45 ports 2 10 100 1000Base T X Gigabit ports combo ports 2 100 1000Base X on SFP port combo P O E Ports Port 1 8 contain P S E function compliant with IEEE802 3af P O E specifications Push reset button 2 to 3 seconds to reset the switch Push reset button 5 seconds to reset the switc
45. h into Factory Default ORing Industrial Networking Corp 9 IES 3240 User s Manual IES 3240 7 11 b 10 a 8 1 g a L D pP I o ON DO IES 3240 LED for PWR When the PWR links the green led will be light on LED for PWR1 When the PWH 1 links the green led will be light on LED for PWR2 When the PWR2 links the green led will be light on LED for R M Ring master When the LED light on it means that the switch is the ring master of O Ring LED for Ring When the led light on it means the O Ring is activated LED for Fault Relay When the fault occurs the amber LED will be light on Console port RJ 45 Reset button Push the button 3 seconds for reset 5 seconds for factory default 10 100Base T X Ethernet ports LED for Ethernet ports ACT status 11 LED for Ethernet ports Link status ORing Industrial Networking Corp 10 IES 3240 User s Manual 3 2 Front Panel LEDs pwr omm on DCponerrey pew Gem on DC power mouie T activarea pwz Gem on DC power mode activated C fox CT O Ring enabled Slowly blinking O Ring topology has problem Fast Fast blinking Fast blinking O Ring work normally O Ring work normally work normally Fault relay Power failure or Amber Port down fail 10 100Base T X Fast Ethernet E LNK ACT Green M Data transmitted 3 3 Top view Panel The bottom panel components of IES 3240 are shown as below 1 Terminal block in
46. he switch If no trap manager is defined no traps will issue Create a trap manager by entering the IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version SNMP Trap Setting Trap Server Setting Server IP Trap Version vi Ovec Trap Server Profile Server IP Community Trap Version nome SNMP Trap Setting interface The following table describes the labels in this screen Server IP The server IP address to receive Trap Community Community for authentication ma horse 0 me sowe SSS ORing Industrial Networking Corp 58 IES 3240 User s Manual 5 1 7 3 SNMPV3 NMP SNMPv3 Setting SNMPv3 Engine ID f465000003001e940a002b Context Table User Table Current User Profiles New User Profile none User ID Authentication Password Privacy Password Group Table Current Group content New Group Table none Security Name User ID Group Name Current Access Tables New Access Table none Context Prefix Group Name Security Level NoAuthNoPriv AuthNoPriv AuthPriv Context Match Rule Exact Prefix Read View Name 0 057557 L lt A Notify View Name MIBView Table Current MIBTables New MIBView Table none View Name Type Excluded Included Note Any modification of SNMPv3 tables might cause MIB accessing rejection Please take
47. he time stamp could be assigned by manual configuration or by SNTP server System Date Specify the year month and day of system clock Y YY Y MM DD BEEN Year 2006 2015 Month Jan Dec Day 1 31 28 System Time Specify the hour minute and second of system clock hh mm ss Hour 0 24 Minute 0 59 Second 0 59 ORing Industrial Networking Corp 19 IES 3240 User s Manual SNTP The SNTP Simple Network Time Protocol settings allow you to synchronize switch clocks in the Internet SNTP Client UTC Timezone GMT Greenwich Mean Tim Edinburgh Lisbon Lonc Address 0 0 0 0 Daylight Saving Period Daylight Saving Offset 0 hours Apply Help SNTP Configuration interface The following table describes the labels in this screen SNTP Client Enable or disable SNTP function to get the time from the SNTP server Daylight Saving Time Enable or disable daylight saving time function When daylight saving time is enabling you need to configure the daylight saving time period UTC Time zone Set the switch location time zone The following table lists the different location time zone for your reference AST Atlantic Standard 4 hours EDT Eastern Daylight ORing Industrial Networking Corp 20 IES 3240 User s Manual CST Central Standard 6 hours 6 am MDT Mountain Daylight MST Mountain Standard 7 hours 5 am PDT Pacific Daylight PST Pacific Standard 8 hours 4 am ADT Ala
48. ing those with error Total frames received and or transmitted with a length of between 128 and 255 octes in clusive including those with error Total frames received and or transmitted with a length of between 256 and 511 octes in clusive including those with error Total frames received and or transmitted with a length of Octets1023 E between 512 and 1023 octes in clusive including those with error Total frames received and or transmitted with a length of between 1024 and MaxSize octes in clusive including those with error The lower 32 bit of the 64 bit OutOctets counter The sum of OutOctetsLo lengths of all Ethernet frames sent from this MAC The upper 32 bit of the 64 bit OutOctets counter The sum of lengths of all Ethernet frames sent from this MAC The number of frames sent that have an Unicast destination MAC address The number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions This counter is Excessive MD applicable in half duplex only and only of DiscardExcessive is one The number of good frames sent that have a Broadcast OutBroadcasts destination MAC address The total number of successfully transmitted frames that experienced exactly one collision This counter is applicable in half duplex only The number of good Flow Control frames sent InPause The number of good Flow Control frames received The total number of succes
49. itches can work under wide temperature dusty environment and humid condition The IES 3240 can be managed by WEB TELNET Consol or other third party SNMP software as well Besides these switches can be managed by a useful utility that we called Super view Super view is powerful network management software With its friendly and powerful interface you can easily configure multiple switches at the same time and monitor switches status 1 2 Software Features World s fastest Redundant Ethernet Ring O Ring Recovery time 10ms over 250 units connection Supports Ring Coupling Dual Homing over O Ring Supports SNMPv1 v2 v3 amp RMON 4 Port base 802 1Q VLAN Network Management Event notification by Email SNMP trap and Relay Output Web based Telnet Console CLI configuration Enable disable ports MAC based port security Port based network access control 802 1x VLAN 802 1Q to segregate and secure network traffic Radius centralized password management SNMPv3 encrypted authentication and access security RSTP 802 1w Quality of Service 802 1p for real time traffic VLAN 802 1Q with double tagging and GVRP supported IGMP Snooping for multicast filtering Port configuration status statistics mirroring security Remote Monitoring RMON ORing Industrial Networking Corp 5 1 3 Hardware Features Redundant two DC power inputs Wide Operating Temperature 40 to 70 C Storage Temperature 40 to 85 C Operatin
50. le Hybrid QinQ Link enable QinQ mode allow you to insert one more VLAN tag in a original VLAN frame Set the port default VLAN ID for untagged devices that connect to the port The range is 1 to 4094 Tagged VIDs Set the tagged VIDs to carry different VLAN frames to other switch Apply Click Apply to set the configurations 5 1 4 2 VLAN Setting Port Based Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored ORing Industrial Networking Corp 48 IES 3240 User s Manual VLAN Setting VLAN Operation Mode Port Based VLAN List VLAN Configuration Port Base interface 1 The following table describes the labels in this screen Click add to enter VLAN add interface E esa Delete Delete exist VLAN ORing Industrial Networking Corp 49 IES 3240 User s Manual VLAN Setting VLAN Operation Mode Group Name Portl2 w iss VLAN Configuration Port Base interface 2 The following table describes the labels in this screen Group Name VLAN name VLAN ID opecify the VLAN ID Add Select port to join the VLAN group Remove Remove port of the VLAN group Apply Click Apply to set the configurations ORing Industrial Networking Corp 50 IES 3240 User s Manual 5 1 5 Traffic Priorilization Traffic Prioritization includes 3 modes po
51. le RSTP function before configuring the related parameters Priority 0 61440 A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root If the value changes You must reboot the switch The value must be multiple of 4096 according to the protocol ORing Industrial Networking Corp 31 IES 3240 User s Manual Max Age Time 6 40 The number of seconds a bridge waits without receiving opanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 The time that controls switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forwarding Delay Time The number of seconds a port waits before changing from its 4 30 Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Apply Click Apply to set the configurations NOTE Follow the rule to configure the MAX Age Hello Time and Forward Delay Time 2 x Forward Delay Time value 1 gt Max Age value gt 2 x Hello Time value 1 Show RSTP algorithm result at this table Root Bridge Information Bridge ID 8000001E94011E7A Root Priority Root Port Root Path Cost Max Age Hello Time Forward Delay RSTP Port Setting Path Cost Priority 1 200000000 0 240 Admin P2P Admin Edge Admin Non Stp priority must
52. ltiple of 16 Apply MSTP Port interface Description Selecting the port that you want to configure Priority 0 240 Decide which port should be blocked by priority in LAN Enter a number O through 240 The value of priority must be the multiple of 16 Path Cost The cost of the path to the other bridge from this transmitting 1 200000000 bridge at the specified port Enter a number 1 through 200000000 Admin P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only ORing Industrial Networking Corp 36 IES 3240 User s Manual be connected to exactly one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means P2P enabling False means P2P disabling Apply Click Apply to activate the configurations MSTP Instance Setting Priority Instance State VLANS 0 61440 Priority must be a multiple of 4096 Apply MSTP Instance interface msanee Setenta om iS tato Enable or tl e matan Proprietary 0 61440 A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root If the value changes You must reboot the switch The value must be multiple of 4096 according to the pro
53. m nasid global configuration command to change the NAS ID Use the 802 1x misc quiet period global configuration command to specify the quiet period value of the switch Use the 802 1x misc TX period global configuration command to set the TX period Use the 802 1x misc supp timeout global configuration command to set the supplicant timeout Use the 802 1x misc server timeout global configuration command to set the server timeout IES 3240 User s Manual switch config 8021x system accountport 1816 switch config 8021x system sharekey 123456 switch config 8021x system nasid test switch config 8021x misc quietperiod 10 switch contig 8021x misc txperiod 5 switch config 8021x misc supportimeout 20 switch contfig 8021x misc servertimeout 20 100 IES 3240 User s Manual 8021x misc maxrequest Use the 802 1x misc switch config 8021x misc number max request global maxrequest 3 configuration command to set the MAX requests 8021x misc Use the 802 1x misc switch config 8021x misc reauthperiod sec reauth period global reauthperiod 3000 configuration command to set the reauth period 8021x portstate Use the 802 1x port switch config ztinterface fastethernet disable reject accept state interface 3 authorize configuration switch config if 8021x portstate command to set the accept state of the selected port Display a summary of switch gt sh
54. n allowed list attack The illegal IP traffic will be blocked This page allows you to configure IP Guard allowed list The IP traffic will be blocked if it was not in allowed list IP Guard Allow List Delete Port Status 192 168 10 66 001E94112547 IP Guard Allow List State interface ORing Industrial Networking Corp 66 IES 3240 User s Manual The following table describes the labels in this screen IP address of the allowed entry MAC address of the allowed entry Port number of the allowed entry If you doubt some allowed IP traffic are abnormal you could block the traffic use this field Active Allow the IP traffic Suspend Block the IP traffic Delete If you want to delete the entry please check this box and apply it IP Guard Super IP List IP Guard is an intelligent and easy use function for IP security It could protect the network from unknown IP the IP not in allowed list attack The illegal IP traffic will be blocked This page allows you to configure IP Guard Super IP list Super IP entry has a special priority the IP has no limited of MAC address and port binding Any IP traffic are allowed when the IP is in the Super IP list IP Guard Super IP List Paddess super IP List IP Address IP Guard Super IP List State interface ORing Industrial Networking Corp 67 IES 3240 User s Manual IP Guard Super IP List IP Guard is an intelligent and easy use function
55. ng tree instances The forwarding time determines how long each of the listening and learning states last before the port begins forwarding Use the spanning tree switch config interface fastEthernet cost interface 2 configuration switch config if zistp path cost 20 command to set the path cost for Spanning Tree Protocol STP calculations In the event of a loop ORing Industrial Networking Corp 94 spanning tree considers the path cost when selecting an interface to place into the forwarding state stp path priority Port Priority Admin P2P of STP priority on this stp admin p2p Auto True False interface stp admin edge Admin Edge of STP True False priority on this interface Admin NonSTP of STP priority on this stp admin non stp True False interface Show spanning tree the spanning tree states G Disable spanning tree switch config no spanning tree configuration a port priority that is used when two switches tie for position as the root switch ORing Industrial Networking Corp Use the spanning tree switch config interface fastEthernet port priority interface 2 command to configure Display a summary of switch gt show spanning tree IES 3240 User s Manual switch config if stp path priority 127 switch config interface fastEthernet 2 switch config if stp admin p2p Auto switch config interface fastEthernet 2
56. notice of the causality between the tables before you modify these tables ORing Industrial Networking Corp 59 The following table describes the labels in this screen IES 3240 User s Manual Context Table Configure SNMP v3 context table Assign the context name of User Table Group Table Access Table MIBview Table ORing Industrial Networking Corp l Zo 3 4 D 6 p 8 9 m O context table Click Apply to change context name Configure SNMP v3 user table User I D set up the user name Authentication Password set up the authentication password Privacy Password set up the private password Click Add to add context name Click Remove to remove unwanted context name Configure SNMP v3 group table Security Name User I D assign the user name that you have set up in user table Group Name set up the group name Click Add to add context name Click Remove to remove unwanted context name Configure SNMP v3 access table Context Prefix set up the context name Group Name set up the group Security Level select the access level Context Match Rule select the context match rule Read View Name set up the read view Write View Name set up the write view Notify View Name set up the notify view Click Add to add context name Click Remove to remove unwanted context name Configure MIB view table ViewName set up the name Sub Oid Tree fill the Sub OID Ty
57. nsumption enhance access speed and present an easy viewing screen Note By default IE5 0 or later version does not allow Java Applets to open sockets You need to explicitly modify the browser setting in order to enable Java Applets to use network ports Preparing for Web Management The default value is as below IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin System Login 1 Launch the Internet Explorer 2 Type http and the IP address of the switch Press Enter ORing Industrial Networking Corp 14 IES 3240 User s Manual File Edit View Favorites Tools Help ae Q rx 9 le 2 J Search S 7 Favorites E 2 El A 3 Address http 192 168 10 1 ls The login screen appears gt mae A A A AAA Key in the username and password The default username and password is admin 5 Click Enter or OK button then the main interface of the Web based management appears Connect En 192 158 10 1 index htm User name V admin Password TIT Remember my password ce Login screen Main Interface Industrial Managed Ethernet Switch www oring networking com Open all System Information mm Sr Oring E System Information Ey Front Panel MN Basic Setting L Redundancy BI Multicast BI Port Setting MM VLAN EN Traffic Prioritization BI DHCP Server Relay SNMP Security
58. nterface ORing Industrial Networking Corp 63 IES 3240 User s Manual The following table describes the labels in this screen 802 1x Portocol Enable or Disable 802 1X Radius Server function Radius Server IP The IP address of the authentication server Server port Set the UDP port number used by the authentication server to authenticate Account port set the UDP destination port for accounting requests to the specified Radius Server Shared Key A key shared between this switch and authentication server NAS Identifier A string used to identify this switch Quiet Period Set the time interval between authentication failure and the start of a new authentication attempt Tx Period oet the time that the switch can wait for response to an EAP request identity frame from the client before resending the request an EAP request Server Timeout Set the period of time the switch waits for a Radius server response A supplicant Re Auth Period Set the period of time after which clients connected must be ames T Apply Click Apply to set the configurations 802 1x Port Authorized Mode Set the 802 1x authorized mode of each port 802 1x Port Authorize Setting Port No Port Authorize Mode Port 01 Port 02 ESCENA Port 04 LEM 1 EE S a 802 1x Port Authorize interface ORing Industrial Networking Corp 64 IES 3240 User s Manual The following table describes the labels in this screen
59. nterface fastethernet 3 switch config if no event systemlog no event smpt Disable port event for switch config interface fastethernet 3 switch config if no event smtp Show system log switch show systemlog client amp server information ORing Industrial Networking Corp 103 IES 3240 User s Manual 6 15 Commands s List SNTP command set sntp enable Enable usi function switch config sntp enable sntp daylight Enable nidi saving switch config Zsntp daylight time if SNTP function sntp daylight period Start time End time function is inactive this command can t be Parameter format yyy y mmdd hh mm is inactive this command can t be sntp daylight offset Set offset of daylight switech config sntp daylight offset 3 Minute saving time if SNTP function is inactive this command can t be Set SNTP server IP if switch config sntp ip 192 169 1 1 SNTP function is inactive this sntp ip IP command can t be sntp timezone Set timezone index switch config sntp timezone 22 Timezone use show snip timzezone command to get more information of index number Show SNTP switch show sntp ae eo show sntp timezone Show index number of switch show sntp timezone Md el mosntp G Disable SNTP___ _ switch contig no smtp ORing Industrial Networking Corp 104 IES 3240 User s Manual deem no sntp daylight Disable daylight switch config no sntp daylight saving time
60. ode to configuration command with a nfig if global configure specific configuration parameters for the interface while in mode switch and Ethernet global configuration enter exit ports mode To exist privileged EXEC mode or end ORing Industrial Networking Corp 85 IES 3240 User s Manual Symbol of Command Level Symbol of Command Level VLAN database Interface configuration 6 2 Commands escenas js Timm Ac Commands a lES 3240 Commands 3240 Commands Show switch switch gt show config tum m show terminal Show console switch show terminal HEN NN write memory switch write memory configuration into permanent memory flash rom system name Configure system switch config system name xxx CUN RN system location Set switch system switch config system location xxx ca meum o system description Set switch system switch config system description primo gt fuesen e system contact Set switch system switch config system contact xxx memes tenor show system info Show system switch gt show system info MEN AN RN ip address Configure the IP switch config ip address lp address address of switch 192 168 1 1 255 255 255 0 Subnet mask 192 168 1 254 Gateway Enable DHCP client switch config ip dhcp function of switch ORing Industrial Networking Corp 86 IES 3240 User s Manual Show IP information of switchzzshow ip switch Disable DHCP client switch config no ip dh
61. of a program Folder document ar Internet resource and Windows will open it Far you Open telnet 192 168 10 1 Cancel Browse Step 2 The Login screen will appear Use the keyboard to enter the Username and Password The same with the password for Web Browser and then press Enter gt 3 IPS 388260C Command Line Interface Username Password 4 SER 00 00 41 YT100 9600 8 N 1 ORing Industrial Networking Corp 84 IES 3240 User s Manual Commands Level User EXEC Begin a session switch Enter logout The user command with your switch or quit available at the level of user is the subset of those available at the privileged level Use this mode to e Enter menu mode Display system information Privileged Enter the enable switch Enter The privileged EXEC command while in disable to command is advance user EXEC mode exit mode Privileged this mode to Display advance function status save configures Global Enter the configure switch co To exit to Use this mode to configuration command while in nfig zt privileged configure privileged EXEC EXEC mode parameters that apply mode enter exit or to your end Switch as a whole VLAN Enter the vlan switch vla To exit to Use this mode to database database n user EXEC configure command while in mode enter VLAN specific privileged exit parameters EXEC mode Interface Enter the interface switch co To exit to Use this m
62. on When DHCP client function is enabling the switch will be assigned the IP address from the network DHCP server The default IP address will be replaced by the IP address which the DHCP server has assigned After clicking Apply button a popup dialog shows up to inform when the DHCP client is enabling The current IP will lose and you should find a new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabling you do not need to assign the IP address The network DHCP server will assign the IP address for the ORing Industrial Networking Corp 18 IES 3240 User s Manual switch and it will be display in this column The default IP is 192 168 10 1 Assign the subnet mask of the IP address If DHCP client function is enabling you do not need to assign the subnet mask Gateway Assign the network gateway for the switch The default gateway is 192 168 10 254 DNS1 Assign the primary DNS IP address DN2 Assign the secondary DNS IP address Apply Click Apply to activate the configurations 5 1 4 4 Time Setting This page includes configurations of SNTP and system clock System Clock Time Setting system Clock System Clock Thu Jan 01 1970 00 39 12 GMT 0800 Jtr Ri see rone ate System Tim E immi ers as aa Set Clock From PC The following table describes the labels in this screen System clock This field shows the current system timer T
63. onitor switch show monitor information monitor Configure source port switch config interface fastEthernet RX TX Both of monitor function 2 switch config if monitor RX Show port monitor switch config interface fastEthernet information 2 switch contig if show monitor Disable source port of switch config interface fastEthernet monitor function 2 switch config if no monitor 6 12 Commands Set List 802 1x command set 8021x enable Use the 802 1x global switch config 8021x enable configuration command to enable 802 1x protocols 8021x system radiousip Use the 802 1x switch config 8021x system IP address system radious IP radiousip 192 168 1 1 global configuration command to change the radious server IP 8021x system serverport Use the 802 1x switch config 8021x system port ID system server port serverport 1815 global configuration command to change the radious server port ORing Industrial Networking Corp 99 8021x system accountport port ID 8021x system sharekey ID 8021x system nasid words 8021x misc quietperiod sec 8021x misc txperiod sec 8021x misc supportimeout sec 8021x misc servertimeout sec ORing Industrial Networking Corp Use the 802 1x system account port global configuration command to change the accounting port Use the 802 1x system share key global configuration command to change the shared key value Use the 802 1x syste
64. ow 8021x the 802 1x properties and also the port sates Disable 802 1x switch config no 8021x function 6 13 Commands Set List TFTP command set Defaults IES 3240 Commands Level Description Example Save configuration to switch config backup TFTP and need to flash backup_cfg specify the IP of TFTP server and the file name of image restore flash restore_cfg Get configuration from switch config restore TFTP server and need flash restore_cfg ORing Industrial Networking Corp 101 IES 3240 User s Manual to specify the IP of TFTP server and the file name of image Upgrade firmware by switch config upgrade TFTP and need to lash upgrade fw specify the IP of TFTP server and the file name of image 6 14 Commands Set List SYSLOG SMTP EVENT command set systemlog ip Set System log server switch config systemlog ip IP address IP address 192 168 1 100 systemlog mode opecified the log switch config systemlog mode client server both mode both show systemlog E Display system log Switch gt show systemlog show systemlog Show system log switch show systemlog client amp server information no systemlog Disable systemlog switch config no systemlog functon smtp enable G Enable SMTP function switch config smtp enable smtp serverip Configure SMTP switch config smtp serverip smtp authentication Enable SMTP switch config smtp authentication eee PED Configure switch
65. pe select the type exclude or included Click Add to add context name Click Remove to remove unwanted context name Show help file 60 IES 3240 User s Manual 5 1 8 Security Five useful functions can enhance security of switch IP Security Port Security MAC Blacklist and MAC address Aging and 802 1x protocol 5 1 8 1 Management Security Only IP in the Secure IP List can manage the switch through your defined management mode WEB Telnet SNMP Mode Enable WEB Management Enable Telnet Management Enable SNMP Management Secure IP List Secure IP1 LILLO Secure IP2 0 0 0 0 IP Security interface The following table describes the labels in this screen IP IP security MODE MODE IP security MODE Enable Disable the IP Enable Disablethe IP security function function Enable WEB Bases iso MRNA the blank to enable WEB Management Management Enable Telnet Mark the blank to enable Telnet Management Management Enable SNMP Mark the blank to enable MPSN Management Management Apply Click Apply to set the configurations 5 1 8 2 Static MAC Forwarding Static MAC Forwarding is to add static MAC addresses to hardware forwarding database If port security is enabled at Port Control page only the frames with MAC addresses in this list will be forwarded otherwise will be discarded ORing Industrial Networking Corp 61 IES 3240 User s Manual MACAddress Po
66. rotection Reverse polarity protection E EA Tree Protocol Physical Characteristic Pe s00 1w for RSTP Rapid Spanning Tree Protocol Dimension W x D x H ipia M35 dd tigre parming B eeg 0steseh Environmental HOF ity QUEUES ature 40 to 85 C 40 to 185 F pee I I I I I I IEA ae ee ee o Operating Temperature Sy eiatiReppertigsty Regulatory approvals 02 1AB for LLDP Link Layer Discovery Protocol Oore ang Orwaroa ONT a 9526 No TN n CREER groups EN61000 4 6 CS EMI UA SP c ENGRQ0Q 4 ENT nee mo80rA 4 EFT EN61000 4 5 Surge SM urity Features S600 A RENATA Gat derformance amp security to expand the VLAN space Safety Warranty 5 years IGMP Snooping for multicast filtering Software Features f E mE E Port configuration status statistics monitoring security SNTP for synchronizing of clocks over network Support PTP Client Precision Time Protocol clock synchronization DHCP Server Client support Port Trunk support MVR Multicast VLAN Registration support O Ring Open Ring O RSTP STP RSTP MSTP Relay output for fault event alarming Network Redundancy Syslog server client to record and view events Warning Monitoring System Include SMTP for event warning notification via email Event selection support RS 232 Serial Console Port RS 232 in RJ45 connector with console cable 9600bps 8 N 1 LED indicators
67. rt No MAC Address Port No 001122334455 Port Security interface The following table describes the labels in this screen MAC Address Input MAC Address to a specific port Select port of switch Add an entry of MAC and port information Delete Delete the entry Show help file 5 1 8 3 MAC Blacklist MAC Blacklist can eliminate the traffic forwarding to specific MAC addresses in list Any frames forwarding to MAC addresses in this list will be discarded Thus the target device will never receive any frame MACAddress MAC Address 0O01E94123456 MAC Blacklist interface ORing Industrial Networking Corp 62 IES 3240 User s Manual The following table describes the labels in this screen MAC Address Input MAC Address to add to MAC Blacklist Select port of switch Add Add an entry to Blacklist table HOPES Help Show help file 5 1 8 4 802 1x 802 1x Radius Server 802 1x makes the use of the physical access characteristics of IEEE802 LAN infrastructures in order to provide a authenticated and authorized devices attached to a LAN port Please refer to IEEE 802 1X Port Based Network Access Control 802 1x Radius Server Radius Server Setting 802 1x Protocol Enable Radius Server IP 192 168 165 Server Port 1812 Accounting Port Shared Key 12245678 NAS Identifier NAS L2 SWITCH Advanced Setting TX Period d Re Auth Period 3 amp 0 iss 802 1x Radius Server i
68. rt base 802 1p COS and TOS DSCP By traffic prioritization function you can classify the traffic into four classes for differential network application IGS 3044GP GC series support 4 priority queues 5 1 5 1 Qos policy Policy QoS Mode Qos Policy Q Use an 8 4 2 1 weighted fair queuing scheme 9 Use a strict priority scheme Traffic Prioritization interface The following table describes the labels in this screen QOS Mode Port base the output priority is determined by ingress port B COS only the output priority is determined by COS only B TOS only the output priority is determined by TOS only B X COS first the output priority is determined by COS and TOS but COS first TOS first the output priority is determined by COS and TOS but TOS first QOS policy Using the 8 4 2 1 weight fair queue scheme the output queues will follow 8 4 2 1 ratio to transmit packets from the highest to lowest queue For example 8 high queue packets 4 middle queue packets 2 low queue packets and the one lowest queue packets are transmitted in one turn Use the strict priority scheme always the packets in higher queue will be transmitted first until higher queue is empty Apply Click Apply to set the configurations ORing Industrial Networking Corp 51 IES 3240 User s Manual 5 1 5 2 Port base priority Port based Priority Port No Priority te UR LOWESt se lt autre LOWES Port 03 Lo Port O4 Lo EXE
69. rver host IP address 192 168 10 50 community public community i i trap version v1 Community string i i remove trap version Switch config v1 v2c no snmp server host 192 168 10 50 snmp i switch config snmp community strings i ing ri community strings public right RO Community string or right switch config snmp RO RW community strings public right RW snmp snmpv3 user Configure the switch config snmp snmpv3 user User Name userprofile for test01 password AuthPW PrivPW password SNMPV3 agent Authentication Privacy password Password Privacy could be empty Password Show SNMP switch show snmp mmo bm o show snmp server Show specified trap switch show snmp server m e no snmp Remove the specified switch config no snmp community strings ity community strings public Community no snmp snmpv3 user Remove specified switch config no snmp User Name user of SNMPv3 snmpv3 user test01 password password agent Privacy AuthPW PrivPW Authentication password could be Password Privacy empty Password no snmp server host G Remove the SNMP J1switch config zino snmp server Host address server host 192 168 10 50 ORing Industrial Networking Corp 98 IES 3240 User s Manual 6 11 Commands Set List Port Mirroring command set Set RX destination switch config monitor rx port of monitor function Set TX destination switch config monitor tx port of monitor function Show port m
70. s will be run at active backup mode Control Port Link to Control Port of the switch in the same ring Control Port used to transmit control signals Enable Dual Homing Mark to enable Dual Homing By selecting Dual Homing mode O Ring will be connected to normal switches through two RSTP links ex backbone Switch The two links work as active backup mode and connect each O Ring to the normal switches in RSTP mode Apply Click Apply to set the configurations Note We don t suggest you to set one switch as a Ring Master and a Coupling Ring at the same time due to heavy load 5 1 1 2 OPEN Ring Open Ring technology can be applied for other vendor s proprietary ring Thus you can add switches of ORing into the network constructed by other ring technology and enable Open Ring to co operate with other vendor s managed switch ORing Industrial Networking Corp 2 IES 3240 User s Manual Open Ring Ed Enable Vender Mox ist Ring Port Porto v 2nd RingPort PortUl v Apply Open Ring interface The application of Open Ring is shown as below ORing Switch ORing Switch ORing Switch Open Ring connection ORing Industrial Networking Corp 28 IES 3240 User s Manual 5 1 1 3 O Chain O Chain is the revolutionary network redundancy technology that provides the add on network redundancy topology for any backbone network providing ease of use while maximizing fault recovery swiftness flexibility
71. sfully transmitted frames that experienced more than one collision This counter is applicable in ORing Industrial Networking Corp 76 IES 3240 User s Manual Total frames received with a length of less than 64 octets but with KA Total frames received with a length of more than 64 octets and ELM RN but with a valid FCS Total frames received with a length of more than MaxSize octets InMACRcvErr Total frames received with an RxErr signal from the PHY Total frames received with a CRC error not counted in Fragments InFCSErr Jabber or RxErr The number of collision events seen by MAC not including those Collisions conted in Single Multiple Excessive or Late This counter is applicable in half duplex only The number of times a collision is detected later than 512 bits times into the transmission of a frame This counter is applicable in half duplex only 5 1 10 5 Port Monitoring Port monitoring function supports TX egress only RX ingress only and both TX RX monitoring TX monitoring sends any data that egress out checked TX source ports to a selected TX destination port as well RX monitoring sends any data that ingress in checked RX source ports out to a selected RX destination port as well as sending the frame where it normally would have gone Note that keep all source ports unchecked in order to disable port monitoring Port Monitoring Port No Destination Port Source Port TX RX TX estimation Po O
72. skan Daylight CET Central European FWT French Winter MET Middle European 1 hour 1 pm MEWT Middle European Winter SWT Swedish Winter EET Eastern European 2 hours 2pm USSR Zone 1 BT Baghdad USSR Zone 3 hours 3 pm WAST West Australian hours 7pm Standard CCT China Coast USSR 8 hours 8 pm Zone 7 JST Japan Standard 9 hours 9 pm USSR Zone 8 EAST East Australian 10 hours 10 pm Standard GST ORing Industrial Networking Corp 2 IES 3240 User s Manual Guam Standard USSR Zone 9 IDLE International Date Line NZST New Zealand 12 hours Midnight Standard NZT New Zealand SNTP Sever IP Set the SNTP server IP address Address Daylight Saving Set up the Daylight Saving beginning time and Daylight Saving Period ending time Both will be different each year Daylight Saving Offset Switch Timer Display the switch current time Apply Click Apply to activate the configurations PTP Client The Precision Time Protocol PTP is a time transfer protocol defined in the IEEE 1588 2002 Set up the offset time standard that allows precise synchronization of networks e g Ethernet Accuracy within the nanosecond range can be achieved with this protocol when using hardware generated timestamps PTP Client Label PTP Client Enable Disable PTP Client ORing Industrial Networking Corp 27 IES 3240 User s Manual 5 1 4 5 LLDP LLDP Link Layer Discovery
73. switch config if stp admin edge True switch config interface fastEthernet 2 switch config if stp admin non stp False 95 IES 3240 User s Manual 6 7 Commands et List QoS command set les 3240 Commands Lovel Descrition Example qos policy Select QOS policy switch config qos policy weighted fair strict lr aeneo fair qos prioritytype Setting of QOS switch config qos prioritytype port based cos only tos priority type only cos first tos first qos priority portbased Configure Port based switch config qos priority portbased Port lowest low middle high qos priority cos Configure COS switch config qos priority cos 22 Priority lowest low mid Priority middle dle high qos priority tos Configure TOS switch config qos priority tos 3 high Priority lowest low mid Priority dle high Display the switch gt show qos information of QoS configuration neqs Disable QoS function switch config no qos 6 8 Commands Set List IGMP command set Example igmp enable Enable IGMP switch config igmp enable tcc Igmp query auto Set IGMP query to switch config lgmp query auto Igmp query force Set IGMP query to switch config lgmp query force T i em show igmp Displays the details of switch show igmp configuration configuration an IGMP configuration show igmp multi Displays the details of switchzzshow igmp multi an IGMP snooping entries G Disable IGMP switch config no igmp O
74. t group system switch config aggregator priority 22 ee n RR aggregator activityport Set activity port switch config aggregator aggregator group Assign a trunk group switch config aggregator group 1 GroupID Port list with LACP active 1 4 lacp workp 2 GroupID 1to3 Or Port list Member port switch config Ztaggregator group 2 list This parameter 1 4 3 lacp workp 3 could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports aggregator group Assign a static trunk switch config aggregator group 1 GroupID Port list group 2 4 nolacp nolacp GroupID 1to3 Or Port list Member port switch config taggreator group 1 list This parameter 3 1 2 nolacp could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 ORing Industrial Networking Corp 91 IES 3240 User s Manual show aggregator Show the information switch show aggregator of trunk group no aggregator lacp Disable the LACP switch config no aggreator lacp 1 comer a no aggregator group G Remove a trunk group switch config no aggreator group 2 mmm 65 Commands To nn set vlan database Enter VLAN configure A database mode o set switch VLAN switch vilan vlanmode 802 1q gvrp mode or switch vlan vlanmode gvrp no vian Disable vlan group by switch
75. t recovery mode will provide redundant links Fast Recovery mode supports 5 priorities only the first priority will be the act port the other ports configured with other priority will be the backup ports Fast Recovery Mode A Motinciuded w Fast Recovery Mode interface ORing Industrial Networking Corp 30 IES 3240 User s Manual The following table describes the labels in this screen Active Activate the fast recovery mode port Port can be configured as 5 priorities Only the port with highest priority will be the active port 1st Priority is the highest Apply Click Apply to activate the configurations 5 1 1 6 RSTP The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol It provides faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol RSTP setting You can enable disable RSTP function and set parameters for each port RSTP Bridge Setting RSTP Mode Priority 0 614440 Max Age 6 40 Hello Time 1 10 Forward Delay Time 4 30 Priority must be a multiple of 4096 2 Forward Delay Time 1 should be greater than or equal to the Max Age The Max Age should be greater than or equal to 2 Hello Time 1 RSTP Setting interface The following table describes the labels in this screen Label Description RSTP mode You must enable or disab
76. to detect SCROLL caps NLM Capture Print echo IES 3240 User s Manual Ol x Ol x ORing Industrial Networking Corp 82 IES 3240 User s Manual Step 4 The COM port properties setting 9600 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control nl x zd Ss uiui Prin EAS 59 COM1 Properties ajx Fort Settings Bits per second seno Data bits E Parity None Stop bits E Flow control None Restore Defaults DK Cancel Apply Disconnected Auto detect Auto detect SCROLL caps NUM Capture Print echo T Step 5 The Console login screen will appear Use the keyboard to enter the Username and Password The same with the password for Web Browser then press Enter IPS 388260C Command Line Interface Username Password Y lt lll E 5545 0000 41 YT100J S600 8 N 1 SCROLL CAPS yum ina FUEN CLI Management by Telnet Users can use TELNET to configure the switches ORing Industrial Networking Corp 83 IES 3240 User s Manual The default value is as below IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the switch from the Windows Run command or from the MS DOS prompt as below Type the name
77. tocol standard rule Apply Click Apply to activate the configurations ORing Industrial Networking Corp 27 IES 3240 User s Manual MSTP Instance Port Instance Priority Path Cost 0 240 1 200000000 0 Auto o Priority must be a multiple of 16 MSTP Instance Port interface Description Set the instance s information except CIST Selecting the port that you want to configure Priority 0 240 Decide which port should be blocked by priority in LAN Enter a number O through 240 The value of priority must be the multiple of 16 Path Cost The cost of the path to the other bridge from this transmitting 1 200000000 bridge at the specified port Enter a number 1 through 200000000 Apply Click Apply to set the configurations ORing Industrial Networking Corp 38 IES 3240 User s Manual 9 1 2 Multicast 5 1 2 1 IGMP Snooping Internet Group Management Protocol IGMP is used by IP hosts to register their dynamic multicast group membership IGMP has 3 versions IGMP v1 v2 and v3 Please refer to RFC 1112 2236 and 3376 IGMP Snooping improves the performance of networks that carry multicast traffic It provides the ability to prune multicast traffic so that it travels only to those end destinations that require that traffic and reduces the amount of traffic on the Ethernet LAN IGMP Snooping IGMP Snooping Enable V2 IGMP Query Mode Disable w IGMP Snooping Table IP Address VLA
78. unction when port link down switch will Flush MAC When Ports Link table Down MAC Address Auto Enable or Disable MAC Learning function Learning Apply Click Apply to set the configurations ORing Industrial Networking Corp 73 IES 3240 User s Manual 5 1 10 3 Port Overview Port statistics show several statistics counters for all ports Port Overview TX TX RX RX TX Port No Type Link State Good Bad Good Bad Abort Packet Packet Packet Packet Packet Packet Collision Port 01 100TX Downl F Port 02 100TX Down RUNE 100TX o Port 04 100TX Down For Port Overview interface The following table describes the labels in this screen ORing Industrial Networking Corp 74 IES 3240 User s Manual 5 1 10 4 Port Counters This page shows statistic counters for the port The Clear button is to reset all counters to zero for all ports Port No InGoodOctetsl o InGoodOctetsHi InBadOctets OutFCSErr A A AA EIA InUnicasts Deferred InBroadcasts InMulticasts IN gt E E EA Octetso4 Octets127 Octets255 Octets511 PE A PEA E PENCEN Octets1023 OctetsMax OutOctetsLo OutOctetsHi Pte E oue OutUnicasts Excessive OutMulticasts OutBroadcasts D O O 5 O0 i OutPause InPause Multiple Undersize Fragments Oversize InMACRcvErr InFCSErr Collisions A A A ee Port Counters interface The following table describes the labels in this screen The lower 32 bits of the 64 bit InGoodOctets count
79. vlan vlan 8021q aggreator 3 PortNumber VLAN by trunk group hybrid link untag 4 tag 3 6 8 hybrid link untag Or UntaggedVID switch vlan vlan 8021q aggreator 3 tag hybrid link untag 5 tag 6 8 TaggedVID List Show VLAN switch vlan ztshow vlan 23 information 6 66 Commands ree Sp ae command set spanning tree enable E Enable spanning tree config spanning tree enable spanning tree priority Configure spanning switch config spanning tree priority 0to61440 spanning tree max age Use the spanning tree switch config spanning tree seconds max age global max age 15 configuration command to change the interval between messages the spanning tree receives from the root switch lf a switch does not receive a bridge protocol data unit BPDU message ORing Industrial Networking Corp 93 spanning tree hello time seconds spanning tree forward time seconds stp path cost 110200000000 IES 3240 User s Manual from the root switch within this interval it recomputed the Spanning Tree Protocol STP topology Use the spanning tree switch config spanning tree hello time global hello time 3 configuration command to specify the interval between hello bridge protocol data units BPDUSs Use the spanning tree switch config spanning tree forward time global forward time 20 configuration command to set the forwarding time for the specified spanni
80. vlan no vlan 2 VID VID no gvrp nogwp i V Disable GVRP switch vlan no gvrp IEEE 802 1Q VLAN vlan 8021q port V Assign a access link switch vlan vlan 802 1q port 3 PortNumber for VLAN by port if thelaccess link untag 33 access link untag port belong to a trunk UntaggedVID group this command can t be applied vlan 8021q port PortNumber Assign a trunk link for switch vian vlan 8021q port 3 VLAN by port ifthe trunk link tag 2 3 6 99 trunk link tag TaggedVID List port belong to a trunk or group this command switch vlan fvlan 8021q port 3 i y trunk link tag 3 20 vlan 8021q port V Assign a hybrid link for switch vlan vlan 8021q port 3 PortNumber VLAN by port ifthe hybrid link untag 4 tag 3 6 8 port belong to a trunk lor hybrid link untag UntaggedVID group this command switch vlan vlan 8021q port 3 tag can t be applied hybrid link untag 5 tag 6 8 TaggedVID List vlan 8021q aggreator V Assign a access link switch vlan vlan 8021q aggreator 3 TrunkID for VLAN by trunk access link untag 33 ORing Industrial Networking Corp 92 IES 3240 User s Manual access link untag group UntaggedVID vlan 8021q aggreator Assign a trunk link for switch vian vlan 8021q aggreator 3 TrunklD VLAN by trunk group trunk link tag 2 3 6 99 trunk link tag Or TaggedVID List switch vlan vlan 8021q aggreator 3 trunk link tag 3 20 vlan 8021q aggreator Assign a hybrid link for switch
81. width in 100 89 IES 3240 User s Manual kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit bandwidth out Value Set interface output switch config interface bandwidth Rate fastEthernet 2 Range is from 100 switch config if bandwidth out 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit show bandwidth Show interfaces switch config interface bandwidth control fastEthernet 2 switch config if show bandwidth state Use the state interface switch config interface Enable Disable configuration fastEthernet 2 command to specify switch config if state Disable the state mode of operation for Ethernet ports Use the disable form of this command to disable the port show interface show interface switch config interface configuration status fastEthernet 2 configuration switch config if show interface configuration show interface status show interface actual switch config ztinterface status fastEthernet 2 switch config if show interface status show interface show interface switch conftig interface accounting Statistic counter fastEthernet 2 switch config if show interface ORing Industrial Networking Corp 90 IES 3240 User s Manual no accounting Clear interface switch config interface accounting fastEthernet 2 information switch config if no accounting 6 4 Commands ree s DN UE set aggregator priority Set por
82. working Corp 42 IES 3240 User s Manual 5 1 3 2 Port Status The following information provides the current port status information Port Status Port No Type Link State Speed Duplex Flow Control Port 01 3 Down Enable jh eee LOOT Down Er Port 03 pips IE LOOT Port Status interface 5 1 3 3 Port Alias The user can define the name of every Ports Can let user convenient management every Port Port Alias Port Alias 5 1 3 4 Rate Limit By this function you can limit traffic of all ports including broadcast multicast and flooded unicast You can also set Ingress or Egress to limit traffic received or transmitted bandwidth Rate Limit Port No Ingress Limit Frame Type Ingress Port 01 Egress Port 02 Port 03 Port 04 Port 05 Hate Limit interface ORing Industrial Networking Corp 43 IES 3240 User s Manual The following table describes the labels in this screen Ingress Limit Frame You can set all Broadcast only Broadcast Multicast Type or Broadcast Multicast Flooded Unicast mode Ingress The switch port received traffic Egess The switch port transmitted traffic Apply Click Apply to activate the configurations 5 1 3 5 Port Trunk Port Trunk Setting You can select static trunk or 802 3ad LACP to combine several physical links with a logical link to increase the bandwidth Port Trunk Setting Port No Group ID Type

Download Pdf Manuals

image

Related Search

Related Contents

User`s manual  KitchenAid Sinks 8534966 User's Manual  SET 7502 manual.qxp - KARMA ITALIANA Srl  rubus-295_15-st  H26検査担当(PDF:218KB)  400 Series - HellermannTyton  Temperature Extension Kit für MP 377 15" Touch daylight  SG-2 VHL002  Sikadur®-53 Grout Marino  Igea SpA Documento unico di valutazione dei rischi da interferenze  