Home
S9™ Series AutoSet™ & Elite™ A
Contents
1. Nominal for aircraft use 115V 400Hz Typical power consumption 70W 80VA Maximum power consumption 110W 120VA Input range 100 240V 50 60Hz Nominal for aircraft use 115V 400Hz Typical power consumption 20W 40VA Maximum power consumption 36W 75VA 5 C to 35 C Note The air flow for breathing produced by this therapy device can be higher than the temperature of the room Under extreme ambient temperature conditions 40 C the device remains safe 10 95 non condensing Sea level to 2 591 m 20 C to 60 C 10 95 non condensing Flame retardant engineering thermoplastic Recommended maximum supplemental oxygen flow 4 L min on woven acrylic and polypropylene fibers with polypropylene carrier Polyester fiber exible plastic 1 8 m 15 mm inner diameter exible plastic 2 m 19 mm inner diameter Flexible plastic and electrical components 2 m 15 mm inner diameter Flexible plastic and electrical components 1 9 m 19 mm inner diameter The 22 mm conical air outlet complies with ISO 5356 1 F F 7 English 90W power supply unit 30W power supply unit Operating temperature Operating humidity Operating altitude Storage and transport temperature Storage and transport humidity Housing construction Supplemental oxygen Hypoallergenic air filter Standard air filter SlimLine air tubing Standard air tubing ClimateLine heated air tubing ClimateLine heated air tubing Air outle
2. or replace at its option the defective product or any of its components This limited warranty does not cover a any damage caused as a result of improper use abuse modification or alteration of the product b repairs carried out by any service organisation that has not been expressly authorised by ResMed to perform such repairs c any damage or contamination due to cigarette pipe cigar or other smoke and d any damage caused by water being spilled on or into an electronic device Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty replaces all other expressed or implied warranties including any implied warranty of merchantability or fitness for a particular purpose Some regions or states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale installation or use of any ResMed product Some regions or states do not allow the 10 English exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights c
3. tubing Displays error message Check ResMed 30 90W Power Supply Unit and fully insert the connector The DC plug is partially inserted into the Fully insert the DC plug back of the device or inserted too slowly A non ResMed power supply unit is Remove the power supply unit and replace with a ResMed connected to the device power supply unit The power supply unit is being covered Make sure that the power supply unit is free from bedding by bedding clothes or other objects that could cover it Displays error message Tube blocked please check your tube tubing is blocked Check your air tubing and remove any blockages Displays error message High leak please check system setup and all connections There is excessive leak Adjust position of mask and headgear Air tubing is not connected properly Connect firmly at both ends The following message is displayed on the LCD after you try to update settings or copy data to the SD card Card error please remove SD card and contact service provider SD card is not inserted correctly Ensure that the SD card is inserted correctly 5 English Problem Possible cause Solution You may have removed the SD card Reinsert the SD card and wait for the home screen or the before settings were copied to the Settings updated successfully press any key message CPAP device to appear on the LCD Note This message only appears once If you re insert the SD card after you have updated your s
4. unit air tubing or packaging A Caution Read instructions before use P21 Protection against insertion of fingers and against vertically dripping water IP20 Not drip proof A Type BF equipment Class equipment 0 Start Stop Manufacturer European Authorised Representative K European RoHS LoT Batch Code REF Catalogue number sN Serial number Direct current Y Lock unlock Remove tub to fill A Keep Dry 6 China pollution control logo 1 DD China pollution control logo 2 Environmental information WEEE 2002 96 EC is a European Directive that requires the proper disposal of electrical and electronic equipment These devices should be disposed of separately not as unsorted municipal waste To dispose of your device you should use appropriate collection reuse and recycling systems available in your region The use of these collection reuse and recycling systems is designed to reduce pressure on natural resources and prevent hazardous substances from damaging the environment If you need information on these disposal systems please contact your local waste administration The crossed bin symbol invites you to use these disposal systems If you require information on collection and disposal of your ResMed device please contact your ResMed office local distributor or go to www resmed com environment Servicing The S9 device is intended to provide safe and rel
5. RESMED S9 Series AutoSet amp Elite POSITIVE AIRWAY PRESSURE DEVICES User Guide English English 59 AutoSet indications for use The S9 AutoSet self adjusting system is indicated for the treatment of obstructive sleep apnoea OSA in patients weighing more than 30 kg The S9 AutoSet self adjusting system is intended for home and hospital use 59 Elite indications for use The S9 Elite CPAP system is indicated for the treatment of obstructive sleep apnoea OSA in patients weighing more than 30 kg The S9 Elite CPAP system is intended for home and hospital use Contraindications Positive airway pressure therapy may be contraindicated in some patients with the following pre existing conditions severe bullous lung disease pneumothorax pathologically low blood pressure e dehydration e cerebrospinal fluid leak recent cranial surgery or trauma Adverse effects Patients should report unusual chest pain severe headache or increased breathlessness to their prescribing physician An acute upper respiratory tract infection may require temporary discontinuation of treatment The following side effects may arise during the course of therapy with these devices drying of the nose mouth or throat nosebleed bloating ear or sinus discomfort eye irritation e skin rashes Masks and humidifiers Recommended masks and humidifiers are available on www resmed com on the Products page under Ser
6. cted against water if used outdoors Enclose the device in the 9 ravel bag for transport 12 English Manufacturer ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Distributed by ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA EC ResMed UK Ltd 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip 9 S9 AutoSet S9 Elite ClimateLine SlimLine and SmartStart are trademarks of ResMed Ltd 59 AutoSet ClimateLine SlimLine and SmartStart are registered in U S Patient and Trademark Office 6 2012 ResMed Ltd 368873 1 2012 10 0123 Global leaders in sleep and respiratory medicine www resmed com
7. ettings the message will not be re displayed The following message is NOT displayed on the LCD after you try to update the settings using the SD card Settings updated successfully press any key The settings were not updated Contact your clinician service provider immediately SD card An SD card has been supplied to gather therapy data from your S9 device and provide settings updates from your clinician When instructed to do so disconnect the S9 device from the power outlet remove your SD card insert it in the protective folder and send it to your clinician For more information on removing and inserting your card refer to the S9 SD Card Protective Folder provided with your device Please retain the S9 SD Card Protective Folder for future use Technical specifications Operating pressure range 4 to 20 cm H20 Maximum single fault steady state 30 cm H20 pressure Pressure measurement tolerance 0 5 cm H20 4 of the measured reading Flow measurement tolerance 6 L min or 10 of reading whichever is greater DECLARED DUAL NUMBER NOISE EMISSION VALUES in accordance with ISO 4871 Sound pressure level 24 dBA as measured according to ISO 17510 1 2002 26 dBA with uncertainty of 2 dBA as measured according to EN ISO 17510 1 2009 Sound power level 34 dBA with uncertainty of 2 dBA as measured according to EN ISO 17510 1 2009 Nominal dimensions L x W x H 153 mm x 140 mm x 86 mm Weight 835g 6 English Input range 100 240V 50 60Hz
8. iable operation when operated in accordance with the instructions provided by ResMed ResMed recommends that the S9 be inspected and serviced by an authorised ResMed Service Centre if there is any sign of wear or concern with device function Otherwise service and inspection of the devices generally should not be required during the five year design life of the device 9 English Limited warranty ResMed Ltd hereafter ResMed warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below Product Warranty period e Mask systems including mask frame cushion headgear and tubing 90 days excluding single use devices e Accessories excluding single use devices e Flextype finger pulse sensors umidifier water tubs atteries for use in ResMed internal and external battery systems 6 months ip type finger pulse sensors 1 year PAP and bilevel device data modules ximeters and CPAP and bilevel device oximeter adapters umidifiers and humidifier cleanable water tubs Titration control devices PAP bilevel and ventilation devices including external power supply units 2 years e Battery accessories e Portable diagnostic screening devices WD I EOOD O This warranty is only available to the initial consumer It is not transferable If the product fails under conditions of normal use ResMed will repair
9. ng or accessory may alter the pressure you actually receive reducing the effectiveness of the treatment Only use the ResMed 90W or 30W power supply unit Use the 90W power supply unit to power the system comprising the device H5i air tubing DC DC converter and battery pack The 30W power supply unit is designed to power the device only and recommended for traveling Only ResMed products are designed to be connected to the module connector port Connecting other devices could damage the device Blocking the air tubing and or air inlet of the device while in operation could lead to overheating of the device A CAUTIONS Do not open the device enclosure There are no user serviceable parts inside Repairs and servicing should only be performed by an authorised ResMed service agent Do not use bleach chlorine alcohol or aromatic based solutions moisturising or antibacterial soaps or scented oils to clean the device humidifier or air tubing These solutions may cause damage and reduce the life of these products e Incorrect system setup may result in incorrect mask pressure reading Ensure the system is correctly set up Be careful not to place the device where it can be bumped or where someone is likely to trip over he power cord e Make sure the area around the device is dry and clean and clear of bedding clothes or other objects hat could block the air inlet or cover the power supply unit Ensure that the device is prote
10. ontact your local ResMed dealer or ResMed office A WARNINGS Read the entire manual before using the device e Use the device only as directed by your physician or healthcare provider Use the device only for the intended use as described in this manual Advice contained in this manual should not supersede instructions given by the prescribing physician If you notice any unexplained changes in the performance of the device if it is making unusual or harsh sounds if the device or the power supply are dropped or mishandled if water is spilled into the enclosure or if the enclosure is broken discontinue use and contact your ResMed Service Center Beware of electrocution Do not immerse the device humidifier power supply or power cord in water In the event of a spill disconnect the device from the power supply and let the parts dry Always unplug the device before cleaning and make sure that all parts are dry before plugging in the device Explosion hazard do not use in the vicinity of flammable anesthetics Make sure the power cord and plug are in good condition and the equipment is not damaged Keep the power cord away from hot surfaces e The device should only be used with masks and connectors recommended by ResMed or by a physician or respiratory therapist A mask should not be used unless the device is turned on Once the mask is fitted ensure that the device is blowing air The vent hole or holes associated with
11. t Product complies with all applicable electromagnetic compatibility requirements EMC according to IEC60601 1 2 for residential commercial and light industry environments It is recommended that mobile communication devices are kept at least 1 m away from the device Information regarding the electromagnetic emissions and immunity of these ResMed devices can be found on www resmed com on the Products page under Service and Support Click on the PDF file for your language Medical Portable Electronic Devices M PED that meet the Federal Aviation Administration FAA requirements of RTCA DO 160 can be used during all phases of air travel without further testing or approval by the airline operator ResMed confirms that the S9 meets RTCA DO 160 requirements Class II double insulation Type BF MAX are not Mask Tube Hoi Electromagnetic compatibility Aircraft use IEC 60601 1 classification Notes The manufacturer reserves the right to change these specifications without notice The temperature and relative humidity settings displayed for ClimateLine or ClimateLine measured values Check with your clinician service provider before using the SlimLine air tubing with devices other than the S9 Pneumatic flow path S9 AutoSet S9 Elite Blower lt Inlet ti 8 English Symbols which appear on these devices The following symbols may appear on your 59 power supply
12. t your mask as described in your mask user guide To start therapy simply breathe into the mask and or press Lie down and arrange the air tubing so that it is free to move if you turn in your sleep To stop treatment at any time remove your mask and or press Note If your clinician has enabled SmartStart your device will start automatically when you breathe into the mask and stop automatically when you remove the mask OaPwn 2 English Cleaning and maintenance Daily Remove the air tubing by pulling on the finger grips on the cuff Hang it in a clean dry place until next use Notes Do not hang the air tubing in direct sunlight as it may harden over time and eventually crack Do not wash the air tubing in a washing machine or dishwasher Weekly 1 Remove the air tubing from the S9 device and the mask 2 Wash the air tubing in warm water using mild detergent 3 Rinse thoroughly hang and allow to dry 4 Before next use reconnect the air tubing to the air outlet and mask Monthly 1 Wipe the exterior of the S9 with a damp cloth and mild detergent 2 Check the air filter for holes and blockage by dirt or dust Replace the air filter if necessary Replacing the air filter Replace the air filter every six months or more often if necessary 1 Remove the air filter cover from the back of the S9 device 2 Remove and discard the old air filter 3 Insert anew ResMed air filter ensuring that it is sit
13. the mask should never be blocked Explanation The device is intended to be used with special masks or connectors which have vent holes to allow continuous flow of air out of the mask When the device is turned on and functioning properly new air from the device flushes the exhaled air out through the mask vent holes However when the device is not operating insufficient fresh air will be provided through the mask and the exhaled air may be rebreathed Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation This applies to most models of CPAP or bilevel devices 1 Ports may be incorporated into the mask or in connectors that are near the mask 11 English Oxygen supports combustion Oxygen must not be used while smoking or in the presence of an open flame Always ensure that the device is turned on and airflow generated before the oxygen supply is turned on Always turn the oxygen supply off before the device is turned off so that unused oxygen does not accumulate within the device enclosure and create a risk of fire Do not leave long lengths of air tubing around the top of your bed It could twist around your head or neck while you are sleeping Do not use electrically conductive or antistatic air tubings Do not use the air tubing if there are any visible signs of damage Only ResMed air tubing and accessories should be used with the device A different type of air tubi
14. ting flat in the air filter cover 4 Replace the air filter cover Notes Ensure the air filter and air filter cover are fitted at all times Do not wash the air filter The air filter is not washable or reusable Troubleshooting If there is a problem try the following suggestions If the problem cannot be solved contact your equipment supplier or ResMed Do not attempt to open these devices Problem Possible cause Solution No display Power is not connected Ensure the power cable is connected and the power outlet if available is on The DC plug is partially inserted into the Fully insert the DC plug back of the device 3 English Problem Possible cause Solution Insufficient air delivered from the device Ramp time is in use Wait for air pressure to build up or change ramp time filter is dirty Replace air filter tubing is not connected properly Check air tubing tubing is blocked pinched or Unblock or free the air tubing Check the air tubing for punctured punctures Mask and headgear are not positioned Adjust position of mask and headgear correctly Incorrect air tubing selected If you are using the SlimLine or Standard air tubing ensure that you have the correct air tubing selected via the menu Device does not start when you breathe into the mask Breath is not deep enough to trigger Take a deep breath in and out through the mask SmartStart Stop There is excessi
15. ve leak Adjust position of mask and headgear Air tubing not connected properly Connect firmly at both ends SmartStart Stop is disabled Enable SmartStart Stop Device does not stop when you remove your mask SmartStart Stop is disabled Enable SmartStart Stop SmartStart Stop is enabled but the device does not stop automatically when you remove your mask Incompatible mask system being used Only use equipment recommended by ResMed The patient is using a nasal pillows Disable SmartStart Stop mask with a set pressure less than 7 cm 0 Pressure rises inappropriately Talking coughing or breathing in an Avoid talking with a nasal mask on and breathe as normally unusual manner as possible Mask cushion is buzzing against the Adjust the headgear skin 4 English Problem Possible cause Solution Displays error message High temperature fault refer to user manual Device has been left in a hot Allow to cool before re use Disconnect the power cord environment and then reconnect it to restart the device Air filter is blocked Replace your air filter Disconnect the power cord and then reconnect it to restart the device tubing is blocked Check your air tubing and remove any blockages Disconnect the power cord and then reconnect it to restart the device Humidifier setting is too high resulting Turn the humidifier setting down and empty the water from in accumulation of water in the air the air tubing
16. vice amp Support For information on using your mask or humidifier refer to the manual supplied with your mask or humidifier 1 English Setup Refer to illustration A Connect the DC plug of the power supply unit to the rear of the S9 Connect the power cord to the power supply unit Plug the other end of the power cord into the power outlet Connect one end of the air tubing firmly onto the air outlet Connect the assembled mask system to the free end of the air tubing ARON Control panel Refer to illustration B The control panel of your S9 devices includes the following items Start Stop button Starts or stops treatment Home menu LCD screen Info menu Allows you to view your sleep statistics Setup menu Allows you to make changes to settings Push dial Turning the dial allows you to scroll through the menu and change settings Pushing the dial allows you to enter into a menu and confirm your choice The Info and Setup menus are disabled if S9 Essentials has been enabled by your clinician 5 35 Navigating the menus Refer to illustration C In general to navigate the menus Turn until the parameter you require is displayed in blue 2 Press 68 The selection is highlighted in orange 3 Turn until you see the setting that you require 4 Press to confirm your choice The screen returns to blue Getting started Make sure the power is connected Adjust the ramp time if required Fi
Download Pdf Manuals
Related Search
Related Contents
manuel d`utilisation ateq f420p Kathrein CAP 910 Manuale d`uso / User Manual Con Le Istruzioni Di - e Benutzerhandbuch E-flite Celectra Tripp Lite PDU3VSR3L2130 power distribution unit PDU Garland SH/IN 3500 Cooktop User Manual Guía del usuario model mf40 band saw welder Dahir du 3 chaoual 1332 (25 août 1914) Copyright © All rights reserved.
Failed to retrieve file