Home

Wzzard™ Sensing Platform Intelligent Edge Nodes

image

Contents

1. 32 Mechanical DraWiNE nerne oT eee 34 Model 35 Wzzara industrial O 35 WzzardC Commerc Model araea A AE E EA 35 Declaration OF COmMPIINCE seriski aain a a a aeai 36 5 COn a a ENEE AEAEE E TEN 38 WARRANTY B B SmartWorx warrants to the original end user purchaser that this product EXCLUSIVE OF SOFTWARE shall be free from defects in materials and workmanship under normal and proper use in accordance with B B SmartWorx instructions and directions for a period of six 6 years after the original date of purchase This warranty is subject to the limitations set forth below At its option B B SmartWorx will repair or replace at no charge the product which proves to be defective within such warranty period This limited warranty shall not apply if the B B SmartWorx product has been damaged by unreasonable use accident negligence service or modification by anyone other than an authorized B B SmartWorx Service Technician or by any other causes unrelated to defective materials or workmanship Any replaced or repaired products or parts carry a ninety 90 day warrant
2. 13 Connecting Your Sensor to WzzardC Commercial Models ccccssccccessecccesececcesececesecceeeceseeneceseuseceeeueceesenecees 14 Powering Wzzard Industrial MOdeIS csccccceseccccsseccceesccccenececeusececeecceseececsusccecuueceeeeseceseusecesenecessenecessueeeesegecs 15 Powering the W2zard Industrial MOCeIS cscccccssecccesscceceececcesececeusececeuecesceneceesenecessuecessuecessueeesenecetseneeets 15 Powering WzzardC Commercial MOdels cccccccssecccessececenececcenececeuseceseeceeeuececeuseceseneceesegecessueeeseecetseneeets 16 esse T AA A E E 16 MountING W2zard Industrial Models ccccccssssssseecececcsassseeeccceeeaeesseeecceessaeesseecceeessaeeseeceeessauanseeeeeeeesaaageeeeeeeenas 17 Mounting Wzzard Industrial Models ciccucesazssnedasidevedetsadontoatsencaudesmndaaddevenedesoucanedecaedassanesdoas onsdadansecdontatvonasvancane s 17 MountING WzzardC Commercial Models 17 Connecting to Your Intelligent Edge Nodes via Bluetooth LE ceecccessecceeseccceesececeeecccseeececeuseceeeuecesseeecessuneeeseness 18 Install the Wzzard App on Your Handheld Device cccccccsseccceeseccceecccsenececeuscceceeceesuecessuseeesenecesseneceesuaeeesagecs 18 CONFIGURING YOUR W2zard Intelligent Edge Nodes ccccccccssssseccceesececeeesseceeceeeseceeeseaseceeesaaueeeessenaeeeessaaaeeess
3. Bluetooth LE Setup Advertise During Sleep Advertise Rate 0 00 10 Username admin Password gt seees 9 18 CONFIGURING YOUR WZZARD INTELLIGENT EDGE NODES RADIO Configuration Parameter Parameter Default Description Screen Range Value 1 65534 1981 Unique identifier for the sensor network This ID must match the ID programmed into the network gateway Network Join 32 hexa The 128 bit encryption key for the network Key decimal keyword which is entered as a 32 hex character characters default string i e 19ABD This key must will return match the key programmed into the this setting network gateway back to the factory default value Advertise Enables sensor broadcast messages over During Sleep the Bluetooth LE interface while the node is asleep Time interval in seconds between each set of broadcast messages during sleep Longer intervals will preserve battery life characters admin Password for configuring the node characters Radio gt Join Duty 0 100 25 The percent of time that the node will advanced Cycle be awake searching for a network to join A higher value allows the node to connect to the gateway faster but uses more battery current Advertise 10 seconds Rate to 24 hours y 19 DEVICE CONFIGURATION Screen Range Value Configuration e imedetes characters max 40 chars Exception 0 10 Det
4. 250 ohm 0 20ma J and K Industrial Model Only Type J 210 to 1 200 C Type K 270 to 1 372 C 0 25 C Typical 2 C 6 C over the temperature range of 40 to 80 C Industrial 0 65 C Commercial Voltage range 0 30 VDC 31 Open Drain Not to be less than 100ma Current Limit Protection None RADIO SPECIFICATIONS SmartMesh IP 802 15 4e RADIO SPECIFICATIONS Conditions Ll oi Frequenc sae a Spread Spectrum DSSS 25 C 50 RH 2dBi Omni m Directional Antenna Antenna 2 m above ground pio O ese q Receiver Packet Data Error Rate PER 1 93 dBm Sensitivity Receiver PER 50 95 dBm Sensitivity Output Power Delivered to a 50 Q load BB BLUETOOTH LE RADIO SPECIFICATIONS No Characteristics Conditions Min Typ Max Units Operation Frequency 2402 2480 MHz Range 32 s PutputPower se High Gain High Gain Mode Mode Standard Mode THIONYL CHLORIDE LITHIUM BATTERIES 2 SUPPLIED WITH PRODUCT Characteristics Conditions Nominal Capacity Nominal Voltage Diameter Helaht Temperature Range 40 to 85 C 33 MECHANICAL DRAWING Wzzard Industrial Models Figure 1 Mechanical drawing for Industrial models WzzardC Commercial Models Figure 2 Mechanical drawing for WzzardC Commercial models 34 MODEL NUMBERS WZZARD INDUSTRIAL MODELS Wzzard Intelligent Edge
5. Configuration Parameter Parameter Default Description Screen Range Value Thermocouple Sensor Enable On Off On Enables disables the sensor for use on the node Sensor Label 32 tempx User defined text field to describe the characters sensor input max 32 chars Measurement Engineering unit of measure max 8 chars Unit Enable On Off Off Show hide the exception alert options for Exception the sensor Setting the alert values will provide a quick publish based on the measurement interval if an alert level is reached n The node will send a publish to the network gateway when the input reaches this value A blank field or no value disables this alert When enabled the node will broadcast the sensor value over the Bluetooth interface Alert High 999999 9 to 999999 9 Alert Low 999999 9 The node will send a publish to the to 999999 9 network gateway when the input reaches this value A blank field or no value disables this alert BLE On Off O Advertisement Enable 23 SUPPLY VOLTAGE Screen Range wee FF Voltage the node a characters sensor input max 32 chars chars Off Enable On Off Show hide the exception alert Exception options for the sensor Setting the alert values will provide a quick publish based on the measurement interval if an alert level is reached On Off Alert Low 2 4 3 0 Recommended The node will send a publish to the value of 2 6 network gateway when the
6. Nodes with SmartMesh IP and Bluetooth LE Model Number WSD2CTJ WSD1CTJ WSD2CTK WSD1CTK Model Number WSD2XVO WSD1XVO Model Number WSD2MA2 WSD1MA2 WSD2CA2 WSD1CA2 WSD2MA3 WSD1MA3 WSD2CA3 WSD1CA3 Model Number WSD2MD2 WSD1IMD2 WSD2CD2 WSD1CD2 Thermocouple Conduit Connector Conduit Connector Conduit Connector Conduit Connector Accelerometer Wireless Mesh 802 15 4e 2 Analog Inputs 1 Digital Output External Antenna M12 Connector Wireless Mesh 802 15 4e 2 Analog Inputs 1 Digital Output Internal Antenna M12 Connector Connector Connector Wireless Mesh 802 15 4e 3 Analog Inputs External Antenna M12 Connector Wireless Mesh 802 15 4e 3 Analog Inputs Internal Antenna M12 Connector Wireless Mesh 802 15 4e 3 Analog Inputs External Antenna Conduit Connector Wireless Mesh 802 15 4e 3 Analog Inputs Internal Antenna Conduit Connector Digital Inputs Connector Connector Connector Connector WZZARDC COMMERCIAL MODELS Wzzard Intelligent Edge Nodes with SmartMesh IP and Bluetooth LE Model Number WCD1TA3 WCD1TD2 WCD1TTJ Wireless Mesh 802 15 4e 3 Analog Inputs Wireless Mesh 802 15 4e 2 Digital Inputs 2 Digital Outputs Wireless Mesh 802 15 4e 2 J type input 1 Digital Output 35 DECLARATION OF COMPLIANCE BB SMart Na Declaration of Compliance The undersigned representing the following supplier B B Smartworx 707 Dayton Road Ottawa Illinois 6
7. like Ethernet or RS 232 485 422 Secure Connections To ensure secure communications the Spectre Network Gateway supports the creation of VPN tunnels using IPsec OpenVPN and L2TP The web interface provides detailed statistics about gateway activities signal strength etc The gateway supports DHCP NAT NAT T DynDNS NTP VRRP control by SMS and many other routing functions The Spectre Network Gateway also provides diagnostic functions which include automatically monitoring the PPP connection automatic restart in case of connection losses and a hardware watchdog that monitors the Spectre Network Gateway status CONTENTS OF PACKAGE The Wzzard Industrial models package includes Wzzard Industrial Intelligent Edge Node e Sensor wire harness cable conduit connection models only e 2 3 6V AA Thionyl Chloride Lithium Batteries e External Antenna some models e Quick Start Guide Anti Skid Disk The WzzardC Commercial models package includes WzzardC Commercial Intelligent Edge Node e 2 3 6V AA Thionyl Chloride Lithium Batteries e Quick Start Guide e Dual lock adhesive Velcro strips HARDWARE INSTALLATION CONNECTING YOUR SENSOR WZZARD INDUSTRIAL MODELS YOUR SENSOR TO WZZARD INDUSTRIAL CONDUIT MODELS ANALOG AND DIGITAL It is best practice that wiring is done prior to installing batteries or powering up the device Remove the four screws that hold the top of the Wzzard node in place Thread the
8. power wireless technology and programmable time synchronization the Intelligent Edge Nodes can operate for multiple years on just two AA lithium batteries The Spectre Network Gateway The Spectre Network Gateway connects to the SmartMesh IP wireless mesh network and the Wzzard Intelligent End nodes through an integrated 802 15 4e radio The Spectre Network Gateway receives the incoming data stream from edge nodes in MQTT SN format and converts the information into MQTT protocol for transport to an MQTT broker on your network or on the Internet Uniquely designed with open source LINUX architecture the Spectre Network Gateway is customizable through installation of software plug in modules Users can create their own plug in modules with common LINUX commands and scripts or add them from B B s existing library Plug in modules are available for establishing communications with the MQTT broker within a number of loT application platform providers including Axeda Xively ILS and SeeControl The Spectre Network Gateway is built for plug and play simplicity with extensive remote management deployment and customization options It connects Ethernet equipment and other devices to the Internet or intranet via either cellular 3G or 10 100 wired Ethernet The standard configuration includes a 10 100 Ethernet port USB host port binary input output I O port and an 802 15 4e radio It also has an auxiliary port that can be configured for other purposes
9. the provisions of the following directives when used in accordance with the instructions contained in the product documentation 1999 5 EC Radio and Telecommunications Terminal Equipment R amp TTE Directive 2011 65 EU Reduction of Hazardous Substances Directive The standards referenced below have been applied EMC EN55022 2010 AC 2011 Information technology equipment Radio disturbance characteristics Limits and methods of measurement EN55024 2010 Information Technology Equipment Immunity Characteristics Limits and methods of measurement EN61000 4 2 2009 ESD Immunity EN61000 4 3 2006 A2 2010 Radiated Immunity EN61000 4 4 2012 EFT Burst Immunity EN61000 4 5 2006 Surge Immunity n a for WzzardC EN61000 4 6 2009 RF Conducted Immunity The authorized representative located within the community maintains a copy of the technical documentation required by the directives B B Smartworx Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Email eSales bb elec com hereby declare that the product named above meets the essential requirements of is in conformity with and the CE mark has been applied according to the relevant European directives listed above using the relevant sections of the European Standards and other normative documents listed above Fahrion Date July 9 2015 Director of Product Management Place Ottawa Illinois USA B B Smartworx 38
10. 1350 USA Herewith declare under our sole responsibility Model Numbers WSDxxxx WSBxxxx where xxxx are alphanumeric characters Description Wzzard Intelligent Edge Node Wzzard Basic Edge Node The standards referenced below have been applied EMC EN 61000 6 2 2005 Immunity standard for industrial environments EN 61000 6 4 2007 Emission standard for industrial environments FCC Part 15 CFR Title 47 2014 ICES 003 2012 Digita Apparatus Industry Canada EN 61326 1 2012 Electrical equipment for measurement control and laboratory use EMC requirements EN 55022 2010 AC 2011 Information technology equipment Radio disturbance characteristics Limits and methods of measurement CISPR 22 Ed 6 0b 2008 Information technology equipment Radio disturbance characteristics Limits and methods of measurement EN 55024 2010 information Technology Equipment Immunity Characteristics Limits and methods of measurement CISPR 24 2013 Information Technology Equipment Immunity Characteristics Limits and methods of measurement IEC EN 61000 4 2 2009 ESD Immunity IEC EN 61000 4 3 2006 A2 2010 Radiated Immunity IEC EN 61000 4 4 2012 EFT Burst Immunity IEC 61000 4 5 2005 Surge Immunity EN 61000 4 5 2006 Surge Immunity IEC EN 61000 4 6 2009 RF Conducted Immunity Environmental EN60068 2 6 2008 Mechanical Vibration 2G 0 012in displacement 10 500 Hz EN60068 2 27 2009 Mechanical Shock 50G 11ms FCC Class B Notice this devic
11. Worx has been advised of the possibility of such loss or damage EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE B B SMARTWORX MAKES NO OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THIS B B SMARTWORX PRODUCT INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED B B SMARTWORX SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON INCLUDING EMPLOYEES DISTRIBUTORS RESELLERS OR DEALERS OF B B SMARTWORX WHICH ARE INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED ABOVE Every reasonable effort has been made to ensure that B B SmartWorx product manuals and promotional materials accurately describe B B SmartWorx product specifications and capabilities at the time of publication However because of ongoing improvements and updating of B B SmartWorx products B B SmartWorx cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes errors or omissions ABOUT WZZARD SENSING PLATFORM WIRELESS CONNECTIVITY WHERE YOU NEED IT The Wzzard intelligent wireless sensor platform makes it quick and easy to connect sensors and communicate their data to your application on your network or on the Internet for visualization analytics or integration into business appli
12. Wzzard Sensing Platform Intelligent Edge Nodes User Manual B B SMARTW RX BB SMARTWDRX International Headquarters B B SmartWorx 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 bb smartsensing com www bb smartworx com support bb smartworx com European Headquarters B B SmartWorx Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Document Wzzard_User_Manual_R3_2815m W 5 About the Wzzard Sensing 6 Wireless 6 Ge gi E E 8 Hardware 9 Connecting Your Sensor Wzzard Industrial MOCEeIS cccccccsseccceesececesececeeneccceusececeueceseeeceseuseceseucessenecessueeetees 9 Connecting Your Sensor To Wzzard Industrial Conduit models Analog and 8 9 Connecting Your Sensor To Wzzard Industrial M12 Models Analog and 8 12 Terminal Block Connections For Wzzard Industrial Models
13. ages 19 E 19 NCS SU e a E 20 20 PANN MO no 21 Internal 1 6 21 2 22 H Ea gig ga ee meme met 23 VOCS 24 Dipta cen 25 DIGIT QUT DUES canora n S r S a O E T EN 26 PC ETOM O ona a a a 26 CONTICUPALION BUO easa e a E a 28 SHECINCALIONS TON Wzzard EOS NOU CS a 29 Wzzard 29 W2zardC Commercial 30 AWZ ra WOG 31 9 5 8 31 052
14. batteries 15 POWERING WZZARDC COMMERCIAL MODELS D CA Ag lt T Ps SS TSAS fe Pe te eee ie 2 8 Postive il MicroUSB Port Remove back cover Insert both batteries with the positive towards the terminal blocks The unit can also be powered through the microUSB connecter LEDS After you have installed the batteries the LED will begin to blink This indicates that the Node is attempting to establish a network connection The LED will cease blinking when a connection is made Status LED Data Solid On Module startup initialization approx 10 sec Slow Blink Attempting to establish connection with SmartMesh IP network 1 sec on 1 sec off Fast Blink Firmware Update in progress 10 blinks per sec Unit is connected to wireless network 16 MOUNTING WZZARD INDUSTRIAL MODELS MOUNTING WZZARD INDUSTRIAL MODELS Wzzard nodes may be mounted either with screws or with their internal magnets Attach Anti Skid disk to bottom of unit to prevent slipping on metal surfaces Flange Mounting Magnetic Mounting Wzzard nodes may be mounted via their Wzzard nodes contain a powerful internal mounting ears M5 10 mounting magnet Pull force 4 7 Ibs 2 13 kg The magnet is in the base of the Wzzard node BBN a W2zzard MOUNTING WZZARDC COMMERCIAL MODELS Velcro Mounting Holster Mounting The Wzzard node may b
15. blets with Bluetooth BLE 4 0 or Smart LE Using the Wzzard app your handheld devices can configure the Wzzard Intelligent Edge Nodes over their Bluetooth connections The intelligent edge nodes can be configured with calibration and scaling information engineering units friendly names geolocation and other descriptive information The MQTT SN protocol is used to transport sensor data to the network gateway MQTT SN is a highly efficient publish subscribe protocol optimized for sending sensor data over wireless networks The platform simplifies physical installation as well The Wzzard Intelligent Edge Nodes can be attached to any surface using screws or their embedded magnetic bases The IP66 rated fiber reinforced polyester PBT housing and the ability to connect to external sensors via conduit fitting cable gland or M12 connector make the units deployable in virtually any industrial or commercial environment Intelligence at the Network Edge The Wzzard wireless platform places intelligence at the network edge The Wzzard Intelligent Edge Nodes can be configured to communicate data only when specified threshold or alert levels are exceeded When reporting they can associate useful information like geolocation device name and battery install date This eliminates unnecessary network traffic eases the processing burden on upstream resources and cuts the cost of cellular data plans when the Gateway is using the cellular data network Thanks to low
16. cations The Wzzard platform connects to a vast range of industry standard sensors It uses Intelligent Edge Nodes and a wireless SmartMesh IP network to transmit sensor data to the Spectre Network Gateway The Spectre Network Gateway can connect to the Internet via wired connections or the cellular data network Wzzard Intelligent Edge Nodes accommodate external sensors with a wide variety of sensor interface options including general purpose analog inputs digital input output and thermocouple They can also contain internal sensors like an accelerometer depending upon the model number Secure Reliable and Highly Scalable Wireless Networking The Wzzard platform uses 802 15 4e wireless SmartMesh IP networking technology to deliver reliable resilient and scalable communication with advanced network management and comprehensive security features The platform uses full SmartMesh IP networking and time synchronized channel hopping to provide up to 99 999 connectivity even in the most demanding RF environments The Wzzard wireless sensor platform enables rapid network deployment and expansion New nodes may be added at any time and the SmartMesh network dynamically self configures as new nodes are added or removed This process is a function of the mesh network itself and does not need to be controlled by the network gateway Easy Configuration and Installation Configuration of the Wzzard sensor platform is easy via Android smart phones or ta
17. ccelerometer 20 4G 8G Granularity 26 Output increases with acceleration in the direction of the arrows an Right BIBS a W2zzard Forward Back Configuration Up Down CONFIGURATION BUTTON When you press and hold the Configuration button on the Node for more than 5 seconds cause the LED to flash quickly a couple of times restore the BLE login and password to factory settings twill restart the device This action will not reset the device back to all factory settings When you press and hold the Configuration button on the node for at least 1 second but less than 5 seconds LED will turn on hold button until LED is seen t will Wake up the device and turn on the BLE radio This will enable the Wzzard App to communicate to the node BiB W2zard Power Supply Sources External Input Voltage 3 3 VDC 5 Connectors M12 1 2 Conduit sensor interface cable included 8 wire 26 gage 6 ft Battery Life Multiple years based on 1 min sensor sampling and reporting Environmental Intended for indoor and outdoor use Operating 40 to 80 C 40 to 176 F Temperature Storage Temperature 40 to 85 C 40 to 185 F Operating Humidity 0 to 95 non condensing LED indicators Data Color Green Blink Attempting to establish network connection Off Device connected to network Enclosu
18. e complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation hereby declare that the products named above meet the essential requirements of and are in conformity with the Standards listed J fike Fahrion Date July 6 2015 Director of Product Management Place Ottawa Illinois USA B B Smartworx 36 BB Smartwenk Declaration of Compliance The undersigned representing the following supplier B B Smartworx 707 Dayton Road Ottawa Illinois 61350 USA Herewith declare under our sole responsibility Model Numbers WCDxxxx where xxxx are alphanumeric characters Description WzzardC Intelligent Edge Node Commercial The standards referenced below have been applied EMC 61000 6 1 2007 Immunity standard for light industrial environments EN 61000 6 3 2006 A1 2011 Emission standard for light industrial environments FCC Part 15 CFR Title 47 2014 ICES 003 2012 Digital Apparatus Industry Canada EN 61326 1 2012 Electrical equipment for measurement control and laboratory use EMC requirements EN 55022 2010 AC 2011 Information technology equipment Radio disturbance characteristics Limits and methods of measurement CISPR 22 Ed 6 0b 2008 Information technology equipment Radio disturbance characteristics Li
19. e mounted with the B B offers a holster mount as an accessory It supplied dual lock adhesive Velcro strips may be purchased as part number WCHOLST ee 17 CONNECTING TO YOUR INTELLIGENT EDGE NODES VIA BLUETOOTH LE INSTALL THE WZZARD APP ON YOUR HANDHELD DEVICE You may install the Wzzard app on your Android handheld device Your handheld device MUST be compatible with Bluetooth LE 4 0 The Android APP version is available on Google Playstore Search store for W2zzard Sensor Application 1 Open the Wzzard App 2 Press the Configuration button on the device for at least 1 second to wake up Bluetooth radio the LED will come on to signify this 3 Press the device you would like to view This screen lets the user view Bluetooth advertisements from the Nodes 4 Press the Configure Device button 5 Pair with the device Default username password is admin admin 6 Press the Radio Setup button to set the Network ID and Network Join Key These must be the same values that you enter in the corresponding network gateway Press the Save button to save the new settings 7 Refer to the Wzzard Bluetooth App User manual for further node programming instructions Documents can be found at http www bb smartsensing com technical documentation F 39 8 11 20 AM RB SMARTWORX gt Device WSD1CTJ Radio Setup Basic See Advanced Settings Network ID 1981 Network Join Key
20. ermines how frequently the node will based seconds to wake up to check for an alarm level A Measurement 24 hours value of 0 disables this feature Non zero Interval values enable the exception alert feature for the sensors Publish 10 seconds 1 minute Determines the interval between publishes Interval to 24 hours to the network gateway GEOLOCATION Configuration Parameter Parameter Default Description Screen ee a Geolocation ae O to 90 0 ee location of the sensor degrees degrees 9999909 9 20 ANALOG INPUTS Configuration Parameter Parameter Default Value Analoginputs Sensor Enable On Off On Enables disables the sensor Sy for use on the node Analog Input 0 Sensor Label 32 ainx User defined text field to characters describe the sensor input max 32 chars V Unit max 8 chars Sensor Span 999999 9 5 0 The value that is reported Point to 999999 9 when the input is at the maximum value Sensor Zero 999999 9 The value that is reported Point to 999999 9 when the input is at the minimum value Enable On Off O Show hide the Exception exception alert options for the sensor Setting the alert values will provide a quick publish based on the measurement interval if an alert level is reached Alert High 999999 9 Lowest of Sensor The node will send a publish to 999999 9 Span Point Sensor to the network
21. g Input 1 AIN2 Analog Input 2 AIN3 Analog Input 3 DIN1 Digital Input 1 DIN2 Digital Input 2 DO1 Digital Output 1 DO2 Digital Output 2 T1 J Type Thermocouple Input 1 positive T1 J Type Thermocouple Input 1 negative T2 J Type Thermocouple Input 2 positive T2 J Type Thermocouple Input 2 negative N C Not Connected GND Ground Input 14 POWERING WZZARD INDUSTRIAL MODELS POWERING THE WZZARD INDUSTRIAL MODELS Remove the 4 black screws that hold the top of the node in place Install two 3 6 V AA Thionyl Chloride lithium batteries In most installations you will only need to place the batteries in the battery holder But in high vibration environments you should also use the optional bettery retaining clip Do not use excessive force while placing or removing the clip as you can break it The best way to remove the clip is to insert a small flathead screwdriver between the batteries and the clip parallel to the batteries and give the screwdriver a gentle twist This will remove the clip without damage As with all batteries these are a fire explosion and severe burn hazard Do not burn or expose them to high temperatures Do not recharge crush disassemble or expose the contents to water Properly dispose of used batteries according to local regulations by taking it to a hazardous waste collection site an e waste disposal center or other facility qualified to accept lithium
22. gateway Zero Point highest of when the input reaches this Sensor Span Point value A blank field or no Sensor Zero Point value disables this alert Alert Low 999999 9 Lowest of Sensor The node will send a publish to 999999 9 Span Point Sensor to the network gateway Zero Point highest of when the input reaches this Sensor Span Point value A blank field or no Sensor Zero Point value disables this alert BLE On Off When enabled the node will broadcast the sensor value 0 20mA 4 5V The type of sensor connected 20mA 0 5V to the input 1 5V ff Advertisement Enable over the Bluetooth interface INTERNAL TEMPERATURE Screen Range Value frome 1 Temperature node characters sensor input max 32 chars Unit Enable On Off Off Show hide the exception alert options for Exception the sensor Setting the alert values will provide a quick publish based on the measurement interval if an alert level is reached n The node will send a publish to the network gateway when the input reaches this value A blank field or no value disables this alert BLE O Advertisement Enable When enabled the node will broadcast the sensor value over the Bluetooth interface Alert High 999999 9 to 999999 9 Alert Low 999999 9 The node will send a publish to the to 999999 9 network gateway when the input reaches this value A blank field or no value disables this alert 22 THERMOCOUPLE
23. input should be reaches this value A blank field or no used value disables this alert BLE On Off When enabled the node will Advertisement Enable broadcast the sensor value over the Bluetooth interface Alert High 3 0 4 0 The node will send a publish to the network gateway when the input reaches this value A blank field or no value disables this alert 24 DIGITAL INPUTS Configuration Screen Digital Inputs Parameter Parameter Default Description Range Value Sensor Enable On Off On Enables disables the sensor for use on the node characters sensor input max 32 chars Measurement Unit Digital Input bool count Engineering unit of measure max 8 chars The type of sensor connected to the input either a Boolean input a counter totalizer or arate meter Enable On Off Off Show hide the exception alert options for Exception the sensor Setting the alert values will provide a quick publish based on the Alert High Boolean 1 Rate 0 0 to 999999 9 measurement interval if an alert level is Alert Low Boolean 0 reached Rate 0 0 to Type rate The node will send a publish to the network gateway when the input reaches this value A blank field or no value disables this alert The node will send a publish to the network gateway when the input reaches this value A blank field or no value disables this alert True False False Changes the input from an active high input t
24. mits and methods of measurement EN 55024 2010 Information Technology Equipment Immunity Characteristics Limits and methods of measurement CISPR 24 2013 Information Technology Equipment Immunity Characteristics Limits and methods of measurement IEC EN 61000 4 2 2009 ESD Immunity 61000 4 3 2006 A2 2010 Radiated Immunity IEC EN 61000 4 4 2012 EFT Burst Immunity IEC EN 61000 4 6 2009 RF Conducted Immunity FCC Class B Notice this device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation hereby declare that the products named above meet the essential requirements of and are in conformity with the Standards listed VA Lh e an Mike Fahrio Date July 9 2015 Director of Product Management Place Ottawa Illinois USA B B Smartworx 37 DECLARATION OF CONFORMITY CE B B SMARTW BRX C 4 Declaration of Conformity The undersigned representing the following supplier B B Smartworx 707 Dayton Road Ottawa Illinois 61350 USA Herewith declare under our sole responsibility Model Numbers WSDxxxx WSBxxxx WCDxxxx where xxxx are alphanumeric characters Description Wzzard Intelligent Edge Node WzzardC Intelligent Edge Node Commercial Wzzard Basic Edge Node These products are in conformity with
25. ng Mounting Certifications FCC IC FCC Part 15 Class A FCC Part 15 247 Industry Canada RSS210 CE EN55022 CISPR EN55022 Class A EN 61000 6 1 2007 Generic immunity standard for residential commercial and light industrial environments EN 61000 6 3 2006 Emission standard for residential commercial and light industrial A1 2011 environments EN61000 4 2 ESD 8kV air 4kV contact EN61000 4 3 RFI 30 EN61000 4 4 EFT EN61000 4 6 Cl Regulatory Approvals ROHS and WEEE Compliant ALL WZZARD MODELS Digital Inputs Voltage range Pull up current Type Isolation 0 48 VDC 0 97V Maximum 1 8V Minimum 32uA Sourcing PNP Sinking NPN Software selectable input None Rate Frequency Inputs Frequency Counter Input Channels Analog Inputs Input ranges Accuracy 25 C Resolution Input load resistance Types Supported Ranges Supported Resolution Accuracy Digital Outputs Does a 1 second measurement at each measurement publish interval 1 1K Hz Accuracy or 1 Hz Uses the falling edge or rising edge based on the Invert Enabled setting Actively counts either the falling edge Invert enabled or rising edge Invert disabled Can use a multiplier to convert to a unit type or count 2 selectable shared with Digital inputs Rolls over at 999999 9 0 5 VDC 0 20 mA Voltage 0 10 full scale reading 0 20 max Current 0 11 full scale reading 0 24 max 12 bit 100 Mega ohm 0 5VDC
26. o an active low input BLE On Off On When enabled the node will broadcast the Advertisement Enable sensor value over the Bluetooth interface True Message 8 characters Message that is displayed when the Boolean input is true Boolean input is false Period seconds 1 0 Measurement period for determining the mO e rate for the rate meter Read only at this time 999999 9 meter 999999 9 25 DIGITAL OUTPUTS Screen Range Value ows a Outputs Sensor Label 32 dox User defined text field to describe the characters sensor input max 32 chars invert Output True False inverts the level of the output BLE When enabled the node will broadcast the Advertisement sensor value over the Bluetooth interface Enable ACCELEROMETER Configuration Parameter Parameter Default Description Screen Range Value Accelerometer ff ovon node characters sensor input max 32 chars Engineering unit of measure BLE On Off On When enabled the node will broadcast Advertisement the sensor value over the Bluetooth Enable interface Measurement range of the accelerometer A lower value will increase the sensitivity of the accelerometer Accelerometer 12 5 25 Frequency Response of the Interval 50 100 accelerometer A higher value will allow 200 400Hz the accelerometer to capture faster events A
27. re Rating Certifications FCC IC FCC Part 15 Class A FCC Part 15 247 Industry Canada RSS210 CE EN55022 EN 61000 6 2 2005 CISPR EN55022 Class A Generic immunity standard for heavy industrial environments EN 61000 6 4 2006 Emission standard for heavy industrial environments A1 2011 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN60255 21 1 EN60255 21 2 Safety UL CSA Class 1 Division 2 Groups A B C D ESD 8kV air 4kV contact RFI EFT Surge Vibration 2g 10 500Hz 0 3mm displacement Shock 50g 11ms half sine wave 18 shocks N WO IEC 60068 2 6 2007 Vibration 2g 10 500 Hz 1 5mm displacement IEC 60068 2 27 2008 Shock 50g 11ms half sine wave 18 shocks Regulatory Approvals ROHS and WEEE Compliant WZZARDC COMMERCIAL MODELS Power Supply Sources External Input Voltage 3 3 VDC 5 Connectors 3 5 mm terminal blocks Analog Input 0 5 VDC 0 20 mA 4 20 mA Digital Input 0 48 VDC Digital Input Frequency 1 1K Hz Accuracy 1Hz Battery Life Multiple years based on 1 min sensor sampling and reporting Environmental Intended for indoor use Operating O to 65 C 32 to 149 F Temperature Storage Temperature 0 to 70 C 32 to 158 F Operating Humidity 0 to 95 non condensing LED indicators One Green LED Data Color Green Blink Attempting to establish network connection Off Device connected to network Enclosure Mounti
28. rews that hold the top of the Wzzard node in place Confirm that the wire harness from the M12 port is connected to the circuit board inside the Wzzard Edge Node Wire your M12 cable according to the diagram below Wzzard M12 Pinout 12 TERMINAL BLOCK CONNECTIONS FOR WZZARD INDUSTRIAL MODELS THERMOCOUPLE It is best practice that wiring is done prior to installing batteries or powering up the device Remove the 4 screws that hold the top of the Wzzard node in place Thread the thermocouple wires through the conduit and attach them to the terminal block It is best practice that wiring is done prior to installing batteries or powering up the device 1 Thermocouple input 1 positive 2 Thermocouple input 1 negative 3 Thermocouple input 2 positive 4 Thermocouple input 2 negative Close the Wzzard node and replace the 4 screws 13 CONNECTING YOUR SENSOR WZZARDC COMMERCIAL MODELS Connect your sensor wires to the terminal block Consult the chart below for terminal block pin assignments PI P2 P1P 28 P1P2 WIRING FOR WZZARDC COMMERCIAL EDGE NODES WITH SMARTMESH IP TB TB TB3 B3 TB4 Pin 1 Pin 2 Pin 1 Pin 2 Pin 1 Pin 2 Pin 1 Pin 2 T T TB4 G GND GND am GND G G GND C B1 B2 T GND GND WcD1TD2 GND GND D2 GND 501 GND Do2 Ti T2 GND 1 2 O1 weoi Ti 12 12 Gnd doz nc 3 3V 3 3V power output AIN1 Analo
29. wire harness through the conduit Plug the included wire harness into the receptacle on the circuit board inside the node Connect your sensor to the wires running from the node s conduit Consult the charts below for wire colors and connections WIRING FOR WZZARD INTELLIGENT EDGE NODES WITH SMARTMESH IP CONDUIT MODELS som nes pme velom oreen te wne orv a av oor no a ae ee oo oe pwsp2crk 3 3v f f o2 anp GND 33v 90 anp cnp wspaxvo 3 3v S S S Sfo 3 3v o T S S S Sfo 3 3V 3 3V power input 3 3REF 3 3V output reference AIN1 Analog Input 1 AIN2 Analog Input 2 AIN3 Analog Input 3 DIN1 Digital Input 1 DIN2 Digital Input 2 DO1 Digital Output 1 DO2 Digital Output 2 GND Ground Input 10 1 2 3 4 5 6 7 8 White Brown Green Yellow Gray Pink Blue Red GND GND D02 GND GND GND D02 GND DO1 poz GND GND GND po1 Do2 GND GND GND GND GND GND GND GND GND GND GND 3 3V 3 3V power input 3 3REF 3 3V output reference AIN1 Analog Input 1 AIN2 Analog Input 2 AIN3 Analog Input 3 DIN1 Digital Input 1 DIN2 Digital Input 2 DO1 Digital Output 1 DO2 Digital Output 2 GND Ground Input 11 CONNECTING YOUR SENSOR WZZARD INDUSTRIAL M12 MODELS ANALOG AND DIGITAL It is best practice that wiring is done prior to installing batteries or powering up the device Remove the four sc
30. y or the remainder of the initial warranty period whichever is longer To receive in warranty service the defective product must be received at B B SmartWorx no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory to B B SmartWorx denoting product serial number and purchase date a written description of the defect and a Return Merchandise Authorization RMA number issued by B B SmartWorx No products will be accepted by B B SmartWorx which do not have an RMA number For an RMA number contact B B SmartWorx at PHONE 800 624 1070 in the U S and Canada or 949 465 3000 or FAX 949 465 3020 The end user shall return the defective product to B B SmartWorx freight customs and handling charges prepaid End user agrees to accept all liability for loss of or damages to the returned product during shipment B B SmartWorx shall repair or replace the returned product at its option and return the repaired or new product to the end user freight prepaid via method to be determined by B B SmartWorx B B SmartWorx shall not be liable for any costs of procurement of substitute goods loss of profits or any incidental consequential and or special damages of any kind resulting from a breach of any applicable express or implied warranty breach of any obligation arising from breach of warranty or otherwise with respect to the manufacture and sale of any B B SmartWorx product whether or not B B Smart

Download Pdf Manuals

image

Related Search

Related Contents

Elta 2444MP3 User's Manual  Tripp Lite IN3001RF User's Manual  GE JM250DFWW Use and Care Manual  Page 1 Page 2 美味しいお米作りにガガせない 速効的に吸収・利用され  LEDイルミネ一シヨン [ 取扱説明書 ]  1. Turn on the Pumani CPAP. - Rice 360˚ Institute for Global health  HP Bicycle 37717C User's Manual  Operating/user manual - Fire & Security Solutions Ltd  介護サービス事業所自己チェックリスト  DESKPOWER 5000 Series User`s Manual  