Home
Z40 User manual rel 1.2 Eng
Contents
1. Standard P a 1 GND DMX 512 E 2DATA controller 3 lt gt QS E ON A 3 3 1 2 4 2 1 2 4 Z A to Lene ii DoF VI NM inla edel ln Lee een NS J O Standard 5 J END DMX 512 EA SPAM controller lt EH P S If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male XLR 3 5 pins connector with a 120 ohm resistor Between pin 2 and 3 The DMX terminator must be plugged into the last unit DMX out panel connector of the DMX line PLACE A 120 OHM RESISTOR BETWEEN PIN 2 AND 3 OF A MALE XRL CONNECTOR AND PLUG IT INTO THE DMX OUT PANEL CONNECTOR OF THE LAST UNIT CONNECTED TO THE DMX LINE PIN 3 PIN 2 Le Z40 LED Controller DMX ADDRESS Z40 LED CONTROLLER can be used in 10 DMX modes 9 ch Default 20 ch 36 ch 5 ch 16 ch 4 ch 1 ch 10 ch or 40 DMX channels If you w
2. 120 149 Pulse open at variable speed from slow to fast 42 6 s 120 ms 150 179 Pulse close at variable speed from slow to fast 42 6 s 120 ms 180 204 192 Random Strobe Master and RGB active 205 229 218 Random Strobe Full Open 230 255 240 DMX CHANNEL Parameter DIMMER CA Move DAMA renge range Mode Option Function Value E 0 255 Proportional dimmer DAMA range range Mode Option Function Value grees 0 255 Proportionalcolour La Z40 LED Controller DUE CHANNEL ES Parameter GREEN Ga Move DAMA gere range Mode Option Function Value E Og 0 255 Proportionalcolour DMX CHANNEL Parameter BLUE a Move DMX range range Mode Option Function Value rm esee 0 255 Proportionalcolour DMX CHANNEL 6 Paramete WHITE Pre programmed White at diff color temperature DMX range Mode Option Function Value 055 No Function 56 105 80 Full Red Green Blue at Full 106 155 130 White DTS IF CHANNEL 9 FUNCTIONS CUSTOM WHITE RECALL Dmx range value 0 79 156 205 180 Custom White Recall 206 255 225 White CTC Channel 7 CTC enabled 256 color temp Correction Macros 2000 K 7200 K IF CHANNEL 9 FUNCTIONS CUSTOM WHITE CREATE Dmx range value 80 160 156 205 Custom White Create RGB levels selectable by DMX 206 255 White CTC Channel 7 CTC enabled 256 color temp Correction Ma
3. Output 2 Ch 3 Output 3 Ch 4 Output 4 Parameter DIMMER RGBW of the output 1 DMX range Value Parameter DIMMER RGBW of the output 2 DMX range Value Parameter DIMMER RGBW of the output 3 DMX range Value DMX CHANNEL 4 Parameter DIMMER RGBW of the output 4 DMX range Value cs Z40 LED Controller 10 CHANNELS MODE Outputs 1 4 have same DMxX starting address previously selected on unit display SHUTTER DIMMER RED GREEN BLUE WHITE WHITE Pre programmed whites at different color temperatures CTC COLOURS MACRO O FUNCTIONS Parameter SHUTTER 8 Pi UI UN E Black out Open Black out 3919 Strobe at variable speed from slow to fast 3 27 s 30 ms 120 149 Pulseopenatvariable speed from slow to fast 42 6 s 120 ms 150 179 ERE Pulse close at variable speed from slow to fast 42 6 s 120 ms 180 204 192 Random Strobe Master and RGB active 205 229 218 Random Strobe Full Open 230 255 240 Parameter DIMMER CET Move DMA range range Mode Option Function Value 0 255 Proportional dimmer DAME reng range Mode Option Function Value IS grees 0 255 Proportionalcolour 2 740 LED Controller DMX CHANNEL E Parameter GREEN Move LAMA range range Mode Option Function Value 0 255 Proportionalcolour X DMX CHANNEL Parameter BLUE M
4. AVIS RISQUE DE HOC ELECTRIQUE NE PAS OUVRIR GEFAHRLICHE N IZSPANNUNG IM INNENTEIL NI WARNING NEVER CON ECT OR DISCONNECT LED UNITS WHEN THI POWER SUPPLY IS TURNED ON ATTENTION 1 OPERATE THIS UNITS ONLY WITH PROMER AC VOLTAGE 2 INSTRUCTION MANUAL BEFORE OPERATION 3 NO USER SERVICEABLE PARTS INSIDE 4 AVOID THE RISK OF ELECTRIC SHOQK AND FIRE DO NOT EJPOSE TO MOISTURE OR HIGH HUMIDITY 5 DISCONNECT MAIN AC PLUG BEFORE OPENING LEDs LEDs LEDs LEDs DODODOSS OUT1 OUT2 OUT3 OUT4 112 1314 15 7 18 R R G G B WW WHITE DONUT RGBW IMPORTANT The maximum number of DONUT unit connectable to each Z40 LEDs output is 1 pc NEVER CONNECT OR DISCONNECT DONUT UNIT WHEN THE POWER SUPPLY IS TURNED ON The Maximum distance between the Z40 and the DONUT unit all models should not exceed 50 meters 24 Z40 LED Controller LED UNITS WIRING CONNECTION Z40 M16 Output 03 LA 120 90 260 Vac U 50 60 Hz CE MADE IN ITALY N a 1 J Oi 2 5 10 AT DMXIN DMX OUT FOS 100 POWER FC E FOS 100 POWER CT FOS 100 POWER FC aria IMPORTANT The maximum
5. Min default 0 RED Max default 255 ENTER BLUE Min default 0 BLUE Max default 255 GREEN Min default 0 GREEN Max default 255 AMBER Min default 0 AMBER Max default 255 SMOOTH Range Off 20 Default 4 GAMMA CORRECTION Linear Linear courrent output Quadratic Linear light output Default ENTER OUTPUT FREQUENCY Range 610 Hz 10 KHz Default 610 Hz BOOST Whit BOOST active the LED s current is set to 500mA 30 more gain Default Disabled La Z40 LED Controller Menu Up Down AUTO ENTER Up Down AUTO ENTER AUTOMATIC MODE SURE Automatic demo game without Menu NO DMX controller Enter YES STEP 01 16 Chase with 16 steps previously created in REC MODE Speed time Wait time and MENU ENTER DOWN UP Dimmer selectable by user AUTO PROGRAM PERSONAL COLOURS STEP RGBA Dimmer and Shutter values selectable by user 0 1 1 6 RAINBOW MENU ENTER DOWN UP Rainbow colours effect Speed time Dimmer and Shutter values selectable by user AUTO PERS COL FIXED COLOURS RED Sixteen Colour Macros as on MACRO channel 1 2 Dimmer and Shutter values eddie A MENU ENTER DOWN UP WHITE MACROS Sixteen macros for White colour AUTO RAINBOW from 2800 to 6500 K Dimmer and Shutter values SPEE selectable by user FIXED COLOURS Sixteen Colour Macros as on MENU ENTER DOWN UP MACRO channel Dimmer and Shutter values AUTO FIXED COL selectable by user ENTER WHIT
6. droits r serv s Ce document ne peut tre copi photocopi ou reproduit dans sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esth tiques fonctionnelles ou de design sans pr avis chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizaci nescrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de car cter est tico funcional o de disefio a cada producto suyo D T S no se asume responsabilidad de ningun tipo sobre la utilizaci n o sobre la aplicaci n de los productos o de los circuitos descritos Z40 LED Controller SYMBOLS Graphic symbols used on this manual THIS SYMBOL INDICATES A HOT SURFACE Never handle the unit until at least 5 minutes have elapsed since the unit was turned off THIS SYMBOL INDICATES ELECTRIC SHOCK RISK High voltage is present inside the unit Unplug the unit prior to performing any function which involves touching the inside of the unit THIS SYMBOL INDI
7. number of FOS 100 POWER LED bar connectable to each Z40 LEDs output is 1 pc NEVER CONNECT OR DISCONNECT THE LED BAR WHEN THE POWER SUPPLY IS TURNED ON The Maximum distance between the Z40 and the FOS 100 POWER LED bar all models should not exceed 50 meters sa Z40 LED Controller LED UNITS WIRING CONNECTION Z40 M16 Output 03 LA 120 f N 2 DATA DMXIN DMX OUT 3 DATA e Pi FOS 50 POWER FC FOS 50 POWER FC au c co IN OUT oai FOS 50 POWER FC END FOS 50 POWER FC END Mo FOS 50 POWER FC AP IN OUT FOS 50 POWER FC END FOS 50 POWER FC END IMPORTANT The minimum number of FOS 50 POWER FC LED bar connectable to each 240 LEDs output is 2 pcs 1x FOS 50 POWER FC IN OUT 1x FOS 50 POWER FC END NEVER CONNECT OR DISCONNECT THE LED BARS WHEN THE POWER SUPPLY IS TURNED ON The Maximum distance between the Z40 and the FOS 50 POWER FC LED bar should not exceed 50 meters The Maximum distance between the Z40 and the last FOS 50 POWER FC unit in the line 2 pcs should not exceed 50 meters NOTES The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from
8. 184 Rainbow Speed 1 6 Sec Rainbow Speed 2 15 Sec Rainbow Speed 3 30 Sec Rainbow Speed 4 45 Sec Rainbow Speed 5 60 See _ Rainbow Speed 6 120 Sec Rainbow Speed 7 150 Sec F Rainbow Speed 8 180 Sec Parameter FUNCTIONS Recall Create and Store the Custom white DMX range Mode Option Function Value Custom White Recall Enable CH 7 for Custom white Recall 80 160 Custom White Create Enable CH 7 for Custom white Creation 161 255 Custom White Store Store the Custom White created 22 740 LED Controller 40 CHANNELS MODE Same DMX chart as per 10ch mode but Outputs 1 4 are automatically assigned to different DMX starting address Ch 1 to 10 Output 1 with DMX chart as per 10ch mode Ch 11 to 20 Output 2 with DMX chart as per 10ch mode Ch 21 to 30 Output 3 with DMX chart as per 10ch mode Ch 31 to 40 Output 4 with DMX chart as per 10ch mode OUTPUT 1 SHUTTER DIMMER RED GREEN BLUE WHITE WHITE Pre programmed whites at different color temperatures CTC COLOURS MACRO 0 FUNCTIONS FWUOON AU OUTPUT 2 11 SHUTTER 12 DIMMER 13 RED 14 GREEN 15 BLUE 16 WHITE 17 WHITE Pre programmed whites at different color temperatures 18 CTC 19 COLOURS MACRO 20 FUNCTIONS OUTPUT 3 21 SHUTTER 22 DIMMER 23 RED 24 GREEN 25 BLUE 26 WHITE 27 WHITE Pre programmed whites at different color temperatures 2
9. 4 2 3 a CE ge E CE O MADE m MALY 7 LE ATRIA mini AAA AAA TEE 6 oL iie TA DMX 512 AVIS RI ACHTUNG GEFARLICHE NEIZSP ANNUI DMXIN DMX OUT 3 DATA WARNING NEVER CONNECT OR DISCONNECT LED UNITS WHEN THE POWER SUPPLY IS TURNED ON PIN s WHHE DMX IN OUT connectors 4 x LEDs outputs Screw terminal panel connector gt CONNECTION WIRES PIN OUT LED COLOURS 8 poles screw terminals The Maximum distance between the Z40 and DELTA 8 head all models DONUT FOS 100 POWER all models and FOS 50 POWER FC should not exceed 50 meters a Z40 LED Controller DMX SIGNAL CONNECTION The unit operates using a digital DMX 512 signal Connection between the controller and the unit or between units must be carried out using a two pair screened 0 5 mm cable and a CANNON XLR 5 pins connector Ensure that the conductors do not touch each other Do not connect the cable ground to the XLR chassis The plug housing must be isolated Connect the mixer signal to the DMX IN of the Z40 plug and connect it to the next unit by connecting the DMX OUT plug on the first Z40 to the DMX IN plug of the second one This way all the projectors are cascade connected
10. 5 Manual rel 1 2 GB 77 5 Illuminazione s r l ITALY http www dts lighting it The Lighting Company Made in Italy E 740 LED Controller Le informazioni contenute in questo documento sono state attentamente redatte e controllate Tuttavia non assunta alcuna responsabilit per eventuali inesattezze Tutti diritti sono riservati e questo documento non pu essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilit sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles inexactitudes Tous
11. 8 CTC 29 COLOURS MACRO 30 FUNCTIONS OUTPUT 4 31 SHUTTER 32 DIMMER 33 RED 34 GREEN 35 BLUE 36 WHITE 37 WHITE Pre programmed whites at different color temperatures 38 CTC 39 COLOURS MACRO 40 FUNCTIONS 2 Z40 LED Controller WIRING DIAGRAMS Z40 M16 Output 03 LA 120 BY U 90 260 V ee 50160 Hz A CE 22 MADE IN ITALY O e DMX 512 1 GND 2 DATA 3 DATA P 4 x LEDs outputs M16 Female panel connector LED OUTPUTS M16 Female M16 Male WIRES SEQUENCE OUT on board 240 on board Delta 8 B HEAD bin 4 BLUE PIN 1 RED PIN 2 GREEN 3 BLUE PIN 3 YELLOW PIN4 WHITE PIN 4 ORANGE l COMMON PIN 5 RED PIN 6 BROWN PIN 7 BLACK PIN 8 GREY NTC f THERMAL PIN 9 WHITE NTC SENSOR Front View Front View The Maximum distance between the Z40 and DELTA 8 head all models DONUT FOS 100 POWER all models and FOS 50 POWER FC should not exceed 50 meters 2 740 LED Controller WIRING DIAGRAMS Z40 Screw terminals output 03 LA 130 1 2 3 90 260 a D iois A CONNECTION y ya O A n A MU 7 f MADE IN ITALY WIRES N TA ine asso CN CAUTION RISK OFE RIC SHOCIKDO NOT OPEN na BED OWN ACHTU VG Tea SIE NICHT OFFNEN AS PIN 3 GREEN UA PIN 4 GREEN DVGOSOSN8 Wi RNING PIN 6 BLUE NE
12. AY interface that lets you enter all functions of the internal menu DMX Z40 LED CONTROLLER can be used in 10 DMX modes 9 ch 36 ch 20 ch 5 ch 16 ch 4 ch 1 ch 10 ch or 40 DMX channels Operating system update Z40 internal operating system can be updated via computer through the dedicated D T S RED BOX interface Control Z40 can be controlled by any DMX console Construction Z40 is housed in a sturdy metal case that offers high resistance to knocks and mechanical stress Z40 is rack mountable 2 rack units The protection rating against external agents is IP20 Connections DMX IN OUT connectors 2x XLR 5 poles by Neutrik and 2x XLR poles by Neutrik LEDs connector output 4 M16 9 poles connectors 03 LA 120 4 x Screw terminals 8 poles connectors 03 LA 130 The Maximum distance between the Z40 and DELTA 8 head all models DONUT FOS 100 POWER all models and FOS 50 POWER FC should not exceed 50 meters MAIN ELECTRICAL CHARACTERISTICS Input Voltage Range Vin 90 260 Vac Frequency 50 60 HZ Power Consumption Range 30 800 W Power Factor Pf 0 95 electronic PFC controller Efficiency 90 typical Output Power Output Range 4 outputs of 4 channels each 2 Z40 LED Controller Max power of each output is 200W 50W per channel Max power of each channel is 50W 50W Red 50W Green 50W Blue and 50W White Output Current 1600mA Output Voltage Vout 48V Constant Current PWM Ma
13. CATES GENERAL RISK THIS SYMBOL MEANS YOU CAN PLACE THE UNIT ON NORMALLY FLAMMABLE SURFACES Suitable for mounting on normally flammable surfaces greater than 200 C with some combustion time lag gt gt gt GENERAL WARNING Read the instruction contained in this user manual carefully as they give important information regarding safety during installation use and maintenance The device is not for domestic use and must be installed by a qualified electrician or experienced person Always disconnect the device from the mains before servicing The device must always be equipped with an efficient ground connection GENERAL WARRANTY CONDITIONS The unit is guaranteed for 36 months from the date of purchase against manufacturing material defects E Z40 LED Controller DESCRIPTION Overview Z40 is a power supply DMX LED controllers designed to control four pcs DELTA 8 heads four pcs DONUT four pcs FOS 100 POWER or eight pcs FOS 50 POWER minimum 2 pcs each output System Z40 is fitted with 4 groups of 4 output channels each max power of each channel is 50W 200W each group Each group can supply and control an independent set up of D T S LED products at the same time like one of the following max 4 x DELTA 8 heads FC max 4 DELTA 8 heads CT max 4 x DONUT max 4 x FOS 100 POWER FC max 4 x FOS 100 POWER CT max 8 x FOS 50 POWER FC minimum 2 pcs each output Interface Z40 is fitted with a LED DISPL
14. D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY The Lighting Company ISO 9001 2008 D T S quality system is certified to the ISO 9001 2008 standard D T S products are designed and manufactured at the D T S plants in italy 05171186 D T S Illuminazione s r l Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it
15. E MACROS COLOR Sixteen macros for White colour from 2800 to 6500 K 1 Dimmer and Shutter values di Oy USEN MENU ENTER DOWN UP AUTO WHITE WHITE NO 1 MENU ENTER DOWN IS I SLAVE IS IS The SLAVE unit receive DMX signal Menu Up Down ENTER Up Down SLAVE from the MASTER unit ENTER SURE By setting all the SLAVE units SLAVE MODE SETTING _ This menu allow to set the 240 as Menu NO connected to the MASTER to DMX slave unit Enter YES address 1 them will be sinchronized DMX signal must be present from with the Master unit following the in order to ran the units in SLAVE chase selected on it mode By setting all the SLAVE units connected to the MASTER to SLAVE DMX address 1 them will be sinchronized with the Master unit SLAVE MODE following the chase selected on MASTER unit MENU ENTER DOWN UP s Z40 LED Controller D ISS WIRELESS ES ES WIRELESS WIRELESS DMX SYSTEM IS WIRELESS DMX pb LaS Wieless DMX enabled disabled SELECTION By activating WDMX MODE it will i to control Z40 us O D T S ANTENNA Wireless DMX Transmitter cod 03 E1271 WIRELESS DMX system on Z40 MENU ENDER CANIN is not implemented WIRELESS DMX system on Z40 WIRELESS EE d EIER is available on request SELECTION MENU ENTER DOWN UP WIRELESS OM ROGO ENT UNLINK MENU ENTER DOWN UP Logging on Z40 WIRELESS DMX must be enabled on the unit To log on the Z40 in the WIRELESS system simply pre
16. RGB active 205 229 218 Random Strobe Full Open 230 255 240 Parameter DIMMER DMX range Value DMX range Value DMX CHANNEL m Parameter GREEN DMX range Value DMX CHANNEL Parameter BLUE DMX range Value 0355 __ Prroportional colour a 740 LED Controller 20 CHANNELS MODE Same DMX chart as per 5ch mode but Outputs 1 4 are automatically assigned to different DMX starting address Ch ito 5 Output 1 with DMX chart as per 5ch mode Ch 6to 10 Output 2 with DMX chart as per 5ch mode Ch 11 to 15 Output 3 with DMX chart as per 5ch mode Ch 16 to 20 Output 4 with DMX chart as per 5ch mode OUTPUT 1 1 SHUTTER 2 DIMMER 3 RED 4 GREEN 5 BLUE OUTPUT 2 6 SHUTTER 7 DIMMER 8 RED 9 GREEN 10 BLUE OUTPUT 3 11 SHUTTER 12 DIMMER 13 RED 14 GREEN 15 BLUE OUTPUT 4 16 SHUTTER 17 DIMMER 18 RED 19 GREEN 20 BLUE 2u Z40 LED Controller 4 CHANNELS MODE Outputs 1 4 have same DMX starting address previously selected on unit display 1 RED 2 GREEN 3 BLUE 4 WHITE M Mio DMX range Mode Option Function Value 0355 Proportional colour mm PN range Mode Option Function Value 0355 Proportional colour DMX range Mode Option Function Value 0355 Proportional colour Value 0255 Proportional colour 22 740 LED Controller 16 CHANNELS MODE Same DMX chart as per 4ch mo
17. VER CONNEC OR DISCONNECT LED PIN7 WHITE UNITS WHEN THE PO VER SUPPLY IS TURNED ON PINS WHITE BLUE NTION 4 x LEDs outputs Screw terminal panel connector CONNECTION 8 poles screw terminals WIRES PIN OUT LED COLOURS DS9090999S9 The Maximum distance between the Z40 and DELTA 8 head all models DONUT FOS 100 POWER all models and FOS 50 POWER FC should not exceed 50 meters 28 740 LED Controller LED UNITS WIRING CONNECTION Z40 M16 Output 03 LA 120 90 260 Vac U 50 60 Hz CE MADE IN ITALY 2 10 AT E DMXIN DMX OUT DELTA 8 B HEAD CT D ES 666060 66666666 AIIITTY AZZIITY 902065 9999959 ELLLER 5558985 5590985 gas Y n IMPORTANT The maximum number of DELTA 8 B HEAD projector connectable to each Z40 LEDs output is 1 pc NEVER CONNECT OR DISCONNECT A DELTA 8 UNIT WHEN THE POWER SUPPLY IS TURNED ON The Maximum distance between the Z40 and the DELTA 8 B HEAD unit all models should not exceed 50 meters SH Z40 LED Controller LED UNITS WIRING CONNECTION Z40 Screw terminals output 03 LA 130 3 4 CAUTION RISK C ELECTRIC SHOCK DO NOT OPEN
18. ant to use the Z40 in 36 channels mode select the DMX MODE 36 CH under the DMX SET menu and set the following addresses on the mixer Projector 1 A001 Projector 2 037 If you want to select the next projector just add 36 Projector 3 073 s A projector 6 A184 If you want to use the 240 in 9 channels mode select the DMX MODE 9 CH under the DMX SET menu and set the following addresses on the mixer Projector 1 001 Projector 2 A010 If you want to select the next projector just add 9 Projector A019 A projector 6 045 Selelcting the DMX address 1 Press the UP DOWN key until you reach the required DMX address The numbers on the display will start flashing but the new DMX address hasn t yet been set 2 Press ENTER to confirm your selection The numbers on the display will stop flashing and the projector is now controlled by the new DMX address TIPS if you keep pushed the UP or DOWN keys the channels are calculated more quickly and you get a faster selection DISPLAY FUNCTIONS MENU ENTER DISPLAY FUNCTIONS 11 Z40 LED Controller GIGS UP DOWN The Z40 display panel shows all the available functions Using these functions it is possible to change some of the parameters and add some functions Changing the DTS setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it Carefully follow the instructions below before carrying o
19. ation of solid and liquid objects The unit is classified as an ordinary appliance and its protection level against the penetration of solid and liquid objects is IP 20 UNIT DIMENSIONS 432 mm Unit Dimensions LxDxH 480 x 310 x 88 mm Weight 7 5 Kg Packing Dimensions LxDxH 490 x 390 x 90 mm Weight 8 5 Kg 4 Z40 LED Controller INPUT OUTPUT CONNECTIONS Z40 M16 Output 03 LA 120 A001 Mains Switch Display Mains 90 260 Vac 50 60 Hz Powercon female panel connector 4 x LEDs outputs 5 M16 Female panel connector M16 Male LED OUTPUTS M16 Female cable connector WIRES SEQUENCE panel connector _ on board DELTA 8 B HEAD on board Z40 FOS 100 and FOS 50 POWER PIN 1 RED PIN 1 BLUE PIN 2 GREEN BLUE PIN 3 YELLOW PIN4 WHITE PIN 4 ORANGE l COMMON PIN 5 RED RED PIN 6 BROWN I GREEN BLUE PIN 7 BLACK WHITE US E NTC THERMAL NTC A SENSOR Front View Front View The Maximum distance between the 240 and DELTA 8 head all models DONUT FOS 100 POWER all models and FOS 50 POWER FC should not exceed 50 meters _ 740 LED Controller INPUT OUTPUT CONNECTIONS Z40 Screw terminals Output 03 LA 130 240 Mains Switch Display Mains 90 260 Vac 50 60 Hz Powercon female panel connector KOU 90 260 Vac
20. cros 2000 K 7200 K _DMX CHANNEL 7 Parameter CTC Colour temperature correction Move DI VOS TELE range Mode Option Function Value degrees IF CHANNEL 6 White Pre programmed WHITE CTC Dmx range value 206 255 0 255 256 color temp Correction Macros 0 2000 K 128 5500 K 255 7200 IF CHANNEL 6 White Pre programmed NO FUNCTION Dmx range value 0 55 0255 No Function ha Z40 LED Controller DMX CHANNEL 8 Paramete COLOUR MACROS IF gt 5 DMX SET ISIS MACRO ISIS STD MENU Up Down ENTER Up Down ENTER Up Down a R Move DMA range range Mode Option Function Value p esses 09344 14 No Function Function 3044 2 4559 Mater 6074 Maro 7589 Mtr 90104 10 49 7 1201344 1352449 Mero O 150 164 Marol O 1653179 Maroll 18014 Maras 195200 Y Mero 21 25 Marold 2629 Macro 2422058 o gt gt Macrot 6 O DMX CHANNEL 8 Parameter COLOUR MACROS IF 8 DMX SET IS I MACRO ISIS EXT MENU Up Down ENTER Up Do
21. de but Outputs 1 4 are automatically assigned to different DMX starting address Ch ito 4 Output 1 with DMX chart as per 4ch mode Ch 5to 8 Output 2 with DMX chart as per 4ch mode Ch 9to 12 Output 3 with DMX chart as per 4ch mode Ch 13 to 16 Output 4 with DMX chart as per 4ch mode OUTPUT 1 1 RED 2 GREEN 3 BLUE 4 WHITE OUTPUT 2 5 RED 6 GREEN 7 BLUE 8 WHITE OUTPUT 3 9 RED 10 GREEN 11 BLUE 12 WHITE OUTPUT 4 13 RED 14 GREEN 15 BLUE 16 WHITE 28 Z40 LED Controller 32 CHANNELS MODE 16 bit Outputs 1 4 are automatically assigned to different DMX starting address Ch ito 8 Output 1 Ch 9to 16 Output 2 Ch 17 to 24 Output 3 Ch 25 to 32 Output 4 OUTPUT 1 1 RED 2 RED FINE 3 GREEN 4 GREEN FINE 5 BLUE 6 BLUE FINE 7 WHITE 8 WHITE FINE OUTPUT 2 9 RED 10 REDFINE 11 GREEN 12 GREEN FINE 13 BLUE 14 3 BLUE FINE 15 WHITE 16 WHITE FINE OUTPUT 3 17 RED 18 RED FINE 19 GREEN 20 GREEN FINE 21 BLUE 22 BLUE FINE 23 WHITE 24 WHITE FINE OUTPUT 4 25 RED 26 RED FINE 27 GREEN 28 GREEN FINE 29 BLUE 30 BLUE FINE 31 WHITE 32 WHITE FINE A Z40 LED Controller 1 CHANNEL MODE Outputs 1 4 have same DMX starting address previously selected on unit display 1 DIMMER RGBW of all outputs at the same time DMX CHANNEL Parameter DIMMER DMX range Value 4 CHANNELS MODE Outputs 1 4 are automatically assigned to different DMX starting address Ch 1 Output 1 Ch 2
22. e priority on Master Dimmer DMX channel 2 SMOOTH VALUE This menu allows to select the value of the delay in milliseconds for RGBA and Dimmer channels reaction to DMX or Program variation 4 25 ms delay Fast response 20 250 ms delay Slow response GAMMA CORRECTION This menu allows to select between Linear current output or Quadratic current output for LEDs Default Quadratic OUTPUT FREQUENCY This menu allows to adjust the PWM frequency value Hz in order to reduce flickering in the process of your camera recordings BOOST DRIVING This menu allows to increase the LED s current from 350mA to 500 mA Default 2 Disabled IR LED Menu Up Down ENTER Up Down GAMMA CORRECTION This menu allow to select between Linear current output or Quadratic current output for LEDs Default Linear OUTPUT FREQUENCY This menu allow to adjust the PWM frequency value Hz in order to reduce flickering in the process of your camera recordings BOOST DRIVING This menu allow to increase the LED s current from 350mA to 500 mA 12 LED RED MIN 0 MENU ENTER DOWN UP LED GREEN MIN 0 MENU ENTER DOWN UP LED BLUE MIN 0 MENU ENTER DOWN UP LED AMBER MIN 0 MENU ENTER DOWN UP LED SMOOTH 4 MENU ENTER DOWN UP LED GAMMA CORR QUAD MENU ENTER DOWN UP LED OUTPUT FREQ 610 MENU ENTER DOWN LED BOOST OFF MENU ENTER DOWN Z40 LED Controller RED
23. enu Up Down ENTER Up Down LIFE TIME This menu shows the total unit life time and the RGBA life time ig Z40 LED Controller TIME i UNIT 13 Hr 08 min MENU ENTER DOWN UP TIME RED O Hr 08 min MENU ENTER DOWN UP TIME GREEN O Hr 08 min MENU ENTER DOWN UP TIME BLUE O Hr 08 min MENU ENTER DOWN UP TIME AMBER O Hr 08 min MENU ENTER DOWN UP IS I SYSTEM Menu Up Down ENTER Up Down FAN MAX SPEED This menu allows to select the internal fans speed FAN MAX SPEED SYSTEM 50 100 INVE Default 100 100 MENU ENTER DOWN UP IS gt SOFTWARE Menu Up Down ENTER Up Down SOFTWARE Display software and four LED driver board software SOFTWARE DISPLAY SOFTWARE Z40 DISPLAY Id ODOFO55A V1 04 Jul 12 2011 MENU ENTER DOWN UP SOFTWARE Z40 DRIVER 1 ENTER 4 LED DRIVER BOARD SOFTWARE Id 0D10048D v1 02 MENU ENTER DOWN UP 2 Z40 LED Controller DMX PROTOCOL 9 CHANNELS MODE Default Outputs 1 4 have same DMX starting address previously selected on unit display SHUTTER DIMMER RED GREEN BLUE WHITE Pre programmed whites at different color temperatures CTC COLOURS MACRO FUNCTIONS OON OA URW N E Parameter SHUTTER DMX range Mode Option Function Value 09 5 poo Black out 10 19 14 Open 2029 24 Black out 30 119 Strobe at variable speed from slow to fast 3 27 s 30 ms
24. h 10 to 18 Output 2 with DMX chart as per 9ch mode Ch 19 to 27 Output 3 with DMX chart as per 9ch mode Ch 28 to 36 Output 4 with DMX chart as per 9ch mode OUTPUT 1 1 SHUTTER 2 DIMMER 3 RED 4 GREEN 5 BLUE 6 WHITE Pre programmed whites at different color temperatures 7 CTC 8 COLOURS MACRO 9 FUNCTIONS OUTPUT 2 10 SHUTTER 11 DIMMER 12 RED 13 GREEN 14 BLUE 15 WHITE Pre programmed whites at different color temperatures 16 CTC 17 COLOURS MACRO 18 FUNCTIONS OUTPUT 3 19 SHUTTER 20 DIMMER 21 RED 22 GREEN 23 BLUE 24 WHITE Pre programmed whites at different color temperatures 25 CIC 26 COLOURS MACRO 27 FUNCTIONS OUTPUT 4 28 SHUTTER 29 DIMMER 30 RED 31 GREEN 32 BLUE 33 WHITE Pre programmed whites at different color temperatures 34 CTC 35 COLOURS MACRO 36 FUNCTIONS 2 740 LED Controller 5 CHANNELS MODE Outputs 1 4 have same DMX starting address previously selected on unit display 1 SHUTTER 2 DIMMER 3 RED 4 GREEN 5 BLUE DMX CHANNEL 1 Parameter SHUTTER range Mode Option Function Value 09 5 poo Black out 1019 14 Open 2029 24 Black out 30 119 Strobe at variable speed from slow to fast 3 27 s 30 ms 120 149 Pulse open at variable speed from slow to fast 42 6 s 120 ms 150 179 EE Pulse close at variable speed from slow to fast 42 6 s 120 ms 180 204 192 Random Strobe Master and
25. ing red green log in mode every free Z40 unit not logged in to any other transmitter will be logged on Z40 Status Display blinking not logged on to a transmitter free Solid display logged on to a transmitter and receiving dmx data 57 EMERGENCY Menu Up Down EMERGENCY Emergency operating mode By setting Emergency mode it will be possible to select one of the 16 pre programmed WHITE cues that will then ran if DMX signal is missing or not available Usefull for Emergency EXIT ilumination on public areas Dimmer level Pan amp Tilt and Zoom values selectable by user 15 ENTER Up Down EMERGENCY SELECTION OFF MENU ENTER DOWN UP EMERGENCY SELECTION ON MENU ENTER DOWN UP EMERGENCY WHITE 1 MENU ENTER DOWN UP EMERGENCY DIMMER 255 MENU ENTER DOWN UP Z40 LED Controller EMERGENCY Disabled Default ENTER EMERGENCY Enabled WHITE 1 16 Default WHITE 1 DIMMER Default 255 K DEFAULT SET Menu Up Down DEFAULT SETTINGS To restore default settings DEFAULT SET ENTER Up Down MENU ENTER DOWN UP DEFAULT SET SURE Menu NO Enter YES MENU ENTER DOWN UP ENTER 57 IS TEMPER C Menu Up Down TEMPERATURE Unit Display temperature visualisation and LEDs output groups 1 4 temperature visualisation C Celsius Ld TEMPER C Dsp 38 1 42 2 41 3 45 4 40 MENU ENTER DOWN UP is 5 TIME M
26. ove DMX range range Mode Option Function Value A eee 0255 Proportional colour DMX CHANNEL commi Parameter WHITE Move Value 0 255 Proportionalcolour Parameter WHITE Pre programmed White at diff color temperature Mode Option Function Value 055 No Function 56 105 80 Full Red Green Blue White at Full 106 155 130 White DTS IF CHANNEL 10 FUNCTIONS CUSTOM WHITE RECALL Dmx range value 0 79 156 205 180 Custom White Recall 206 255 225 White CTC Channel 8 CTC enabled 256 color temp Correction Macros 2000 K 7200 K IF CHANNEL 10 FUNCTIONS CUSTOM WHITE CREATE Dmx range value 80 160 156 205 Custom White Create RGBW levels selectable by DMX 206 255 White CTC Channel 8 CTC enabled 256 color temp Correction Macros 2000 K 7200 K _DMX CHANNEL 8 Parameter CTC Colour temperature correction Move rues range Mode Option Function Value degrees IF CHANNEL 7 White Pre programmed WHITE CTC Dmx range value 206 255 0 255 256 color temp Correction Macros 0 2000 K 128 5500 K 255 7200 IF CHANNEL 7 White Pre programmed NO FUNCTION Dmx range value 0 55 0 255 No Function 740 LED Controller DMX CHANNEL 9 Paramete COLOUR MACROS IF gt 5 DMX SET ISIS MACRO ISIS STD MENU Up Down ENTER Up Down ENTER Up Down a R Move DMA range range Mode Option Function Value p e
27. ss and quickly release the function button on the transmitter The transmitter will start flashing rapidly red green scanning for new free receivers Z40 units When a Z40 logs on to the transmitter the LINK green light on transmitter starts to flash rapidly After approximately 10 seconds the transmitter will jump back to normal mode and continue transmitting data The Z40 now try to synchronize to the transmitter When synchronized to the transmitter 2 different modes are possible 1 Antenna transmitter has detected and transmits a DMX signal in this mode a solid green light is seen on the transmitter and solid display is seen on Z40 2 No DMX signal connected the Antenna transmitter will flash red green display blinking on Z40 To log off Z40 from a transmitter simply select UNLINK function under WIRELESS DMX MENU and press ENTER When Z40 is logged off the display is blinking meaning its available for log in on a new transmitter Logging out a Z40 Select UNLINK function under WIRELESS DMX MENU and press ENTER When Z40 is logged off the display is blinking meaning its available for log in on a new transmitter Logging out all Z40 units linked to a transmitter Press and hold the function button of the transmitter for about 3 seconds When the display is blinking on Z40 it mean that the units are logged out Transmitter Status LED Flashing red green no dmx connected Solid green dmx signal detected and transmitted Fast flash
28. sses 09344 14 No Function Function 3044 2 4559 Mater 6074 Maro 7589 Mtr 90104 10 49 7 1201344 1352449 Mero O 150 164 Marol O 1653179 Maroll 18014 Maras 195200 Y Mero 21 25 Marold 2629 Macro 2422058 o gt gt Macrot 6 O DMXCHANNEL 9 Parameter COLOUR MACROS IF 8 DMX SET ISIS MACRO ISIS EXT MENU Up Down ENTER Up Down ENTER Up Down a R Move DMA range range Mode Option Function Value 034 14 NoFuncion Function TER a 353 Mer 354 Mars Casa TT Mar O Mares OO 65 74 Macro 75 84 Macro 85 94 Macro 95 104 Macro 9 105 114 1 Mamel 115 124 Mero nsi TT Mae nsi Mer Mero Caisa Mae 1 4644 1 l Mae i Z40 LED Controller DMXCHANNEL 9 Parameter COLOUR MACROS IF IF IF DMX SET IF IF MACRO ISIS EXT IS ENTER Move DMX range range Mode Option Function Value degrees 175
29. ut any variations or selections NOTE the symbol gt Z40 Software version 2 01 shows which key has to be pushed to obtain the desired function SP ques Display SI DISPLAY een abd ON THE GROUND Default ce DISPLAY POSITION STAND BY POSITION SUSPENDED Display Position Reverses display s reading depending on the AA mounting position on the ground or suspended MENU ENTER DOWN UP Display Standby To turn off the display after 30 seconds or leave it always on DISPLAY Display standby ASA OFF Display Standby disabled STANDBY Default ON Display goes off after 30 seconds MENU ENTER DOWN UP IS IS DMX Set DMX mode Menu Up Down ENTER Up Down DMX SET 36 ch 20 ch 9 ch Default RB ENTER DMX MODE MACRO DMX Mode SIYE PI MN channels mode To select DMX mode 9 ch default 36 ch 20 ch 5 ch 16 ch 4 ch 1 ch 10 ch or 40 DMX channels mode Macro Macro Function enable channel mapping macro rainbow effects STD default 9 CH MENU ENTER DOWN DMX SET MACRO STD MENU ENTER DOWN UP UP MACRO Standard mode enabled Default Extended mode enabled Rainbow effects on MACRO channel R LED Menu Up Down ENTER Up Down RGBA MINIMUM VALUES This menu allows to select the minimum levels for Red Green Blue and Amber White RGBA MAXIMUM VALUES This menu allows to select the maximum levels for Red Green Blue and Amber White These settings hav
30. wn ENTER Up Down a R Move DMA range range Mode Option Function Value 034 14 NoFuncion Function TER a 353 Mer 354 Mars Casa TT Mar O Mares OO 65 74 Macro 75 84 Macro 85 94 Macro 95 104 Macro 9 105 114 1 Mamel 115 124 Mero nsi TT Mae nsi Mer Mero Caisa Mae 1 4644 1 l Mae 2 Z40 LED Controller DMXCHANNEL 8 Parameter COLOUR MACROS IF IF IF DMX SET IF IF MACRO ISIS EXT IS ENTER Move DMX range range Mode Option Function Value degrees 175 184 Rainbow Speed 1 6 Sec Rainbow Speed 2 15 Sec Rainbow Speed 3 30 Sec Rainbow Speed 4 45 Sec Rainbow Speed 5 60 See _ Rainbow Speed 6 120 Sec Rainbow Speed 7 150 Sec F Rainbow Speed 8 180 Sec DMXCHANNEL 9 Parameter FUNCTIONS Recall Create and Store the Custom white DMX range Mode Option Function Value Custom White Recall Enable CH 6 for Custom white Recall 80 160 Custom White Create Enable CH 6 for Custom white Creation 161 255 Custom White Store Store the Custom White created a Z40 LED Controller 36 CHANNELS MODE Same DMX chart as per 9ch mode but Outputs 1 4 are automatically assigned to different DMX starting address Ch ito 9 Output 1 with DMX chart as per 9ch mode C
31. x Load each output 1x DELTA 8 head unit 1x DONUT unit 1x FOS 100 POWER unit minimum 2x FOS 50 POWER unit Control Input Control Signal DMX 512 Dimming System Constant Current PWM Address Range DMX 512 channels addressable by display Z40 LED Controller IMPORTANT SAFETY INFORMATION Fire prevention It is permissible to place the unit on normally flammable surfaces F Suitable for mounting on normally flammable materials surfaces greater than 200 C with Some combustion time lag Replace any blown or damaged fuses only with those of identical value 10AT Prevention from electric shock A High voltage is present inside the unit Unplug the unit prior to performing any operation which involves touching the inside of the unit This equipment must be grounded do not connect to non grounded supplies The use of a thermal magnetic circuit breaker is recommended for each Z40 Use only AC supplies 90 260V 50 60 Hz The unit should never be located in position exposed to rain or in areas of extreme humidity A good air ventilation is essential for proper equipment work Safety The external surface of the unit may exceed 50 C never handle the unit until at least 5 minutes have elapsed since the unit was turned off Never install the unit in an enclosed area lacking sufficient air flow The ambient temperature should not exceed 40 C and should not be lower than 10 C Level of protection against the penetr