1. b Main Control Touch Pad Lights Not Lit Ensure power cord is plugged in to the proper power receptacle and dedicated circuit breaker Ensure main circuit breaker house is not tripped power is found at the receptacle Ensure the room main controller circuit breaker under the bench is not tripped and is ON c Room not heating Ensure power cord is plugged in to the power receptacle Ensure all junction boxes are properly connected under the bench per the Power Junction Box Connection Code of 4a Ensure main circuit breaker house is not tripped power is found at the receptacle Ensure the room main controller circuit breaker under the bench is not tripped and is ON Ensure room desired temperature is greater than room actual temperature controller demands heat For additional assistance or service questions Please do not hesitate contacting Mercola Customer Services Mon Fri 7AM 8PM CST Sat Sun 8AM 5PM CST Inside US 1 877 985 2695 Outside US 7 847 252 4355 En Espanola 1 877 985 2690 You may also contact us at http shop mercola com customerservice aspXx An online form is available 24 7 Please allow 48 72 hours for a response from Mercola Customer Services 11 DR MERCOLA VITALITY INFRARED SAUNAS PREMIUM WARRANTY Mercola warrants the Vitality Saunas Infrared against malfunction or defects in materials manufacturing or workmanship for the period of time and in accordance with the conditions s
2. Wall to the Left Wall by lifting up the Right wall sliding into back wall bracket Connect the L 1 electrical connection power feed to the L 1 Junction Box secure the L 1 Junction Box cover with 2 Phillips screws Bench Skirt Box 1 e Insert the Bench Skirt in between the Right Wall and the Left Wall sections e Connect the S 3 electrical connection power feed to the S 3 Junction Box e Secure the S 3 Junction Box cover with 2 Phillips screws Slide the Fan Assembly Box 1 into the Bench Shirt Bracket Attach white connector from the Black Power Box to the Fan white connector Main Power Control Black Box 2 Connections Locate the Main Power Control Black Box which is secured to the Sauna interior floor 1 Insert the 24 pin multi colored wire connector into left side of Main Control Black Power Box 2 Located on the right side of the Main Power Control Black Box is the ON OFF switch Move the switch to the ON position as shown above Note Do NOT Plug the Sauna Room 120 VAC Power Cord into the Outlet Yet Bench Box 1 Slide the Bench seat down against the back wall with Power Junction Box facing you Tilt the Bench against the Back Wall as shown below Connect the S 1 electrical connection power box to the S 1 Junction Box Secure the S 1Junction Box cover with 2 Phillips screws Lay the Bench down and slide back into place as shown Front Wall Box 2 e Place the Front Wall into the Floor section slot sho
3. Dr Mercola Vitality Infrared Sauna 1 amp 2 Person User Manual 10 Precautions before Use Warning Room Configuration amp Use Proper Electrical Grounding is Required Electrical Receptacles not Allowed in the Room Do not Apply Water to any Heating Element Do not Add a Locking or Latching System to the Door Do not Block Ventilation Openings Children Must be Supervised at all Times in the Sauna Electrical Caution Do not plug the room power cord into an electrical outlet until Room Assembly is completed a Warning Human Limitations Prolonged Exposure at Elevated Temperatures May Cause Hyperthermia Body Temperature is Several Degrees Above 98 6F Hyperthermia Symptoms include Dizziness Lethargy Drowsiness and Fainting Hyperthermia Effects Failure to Recognize the Need to Exit the IR Room Fetal Damage in Pregnant Women Physical In Ability to Exit the Room Loss of Consciousness Notice Use of Alcohol or Drugs Increases the Risk of Fatal Hyperthermia lf You Have any Health Problems or Health Conditions Consult Your Physician Prior to Sauna Us Discontinue Use if Nervousness Tremor Headache Feeling of Sickness or Nausea Occurs b Warning Fire Hazards Do Not Use the Sauna Room for Drying Cloths Bathing Suits Etc Do Not Hang Towels or Other Objects on Heater Grills Never Operate this Sauna Room if it Has a Damaged Cord or Plug Pre assembly Information a Two 2 adults are required for the assembly and i
4. EEN 4th press BLUE GREEN 5th press BLUE 6th press BLUE RED 7th press BLUE RED GREEN 8th press Activates full rotation of all 7 color therapy in sequence noted above 9th press Turns Color Therapy Functions OFF Radio and CD Player Operations See Included Radio Operations Manual in Box 1 How to Use Infrared Sauna Avoid eating large meals and excessive alcohol intake before using Sauna Never smoke or drink alcohol or exercise inside of Sauna If you are taking any medication or under the care of a Physician care always consult your Physician prior to Sauna usage Refer to Sauna Usage Warning signs located inside of Sauna Room Prior to Sauna session if possible before using Sauna take a warm shower without drying Clothing is optional or wear loose fitting clothes You may choose to sit or lie on a clean soft towel Set desired time amp temperature Control pad is located outside and inside of Sauna Enter Sauna and relax you may choose to enjoy music with the Sauna CD Radio MP3 Player Refer to the above Color Therapy System instructions Sit or lie on bench Close the door and open the interior ceiling vent allowing for fresh air circulation Remain in the Sauna long enough to warm up and stimulate a mild perspiration Typically that may occur in 10 15 minutes This varies with every individual and their comfort level Do not over do it Drink plenty of cool water or a refreshing healthy drink while
5. et forth below Mercola will provide replacement parts for malfunction or defects from the date and of the original purchase This warranty does not cover shipping cost or any potential labor of warranty parts replacement This warranty applies when the warranted product a is installed in accordance with installation instructions provided b is properly and reasonably maintained and c has not been subjected to damage misuse or abuse This warranty is non transferable and shall extend only to the original purchaser Under no circumstances shall Mercola be liable by virtue of this warranty or otherwise for any special indirect secondary incidental or consequential damage of any nature to any person or property arising directly or indirectly out of the use or inability to us a warranted product The Warranty applies when the warranted product is installed in accordance with instructions provided and is properly and reasonably maintained and has not been subjected to damage misuse or abuse Warranty DOES NOT COVER Labor or freight charges The Sauna Room Wood Components are warranted for lifetime of the product from date of original purchase Mercola will provide full replacement of wood components for manufacturing or workmanship defects Exclusions are minor cracks due to wood expansion and contraction and normal wear and tear Note that since the wood used in Mercola Vitality Saunas has been kiln dried a certain amount of expansion and co
6. ked in Box 1 Attach Wood Magazine Rack with 4 Phillips and Phillips Screwdriver to the interior front wall lower right corner Sauna Room 120 Volt AC Power Cord e Plug the Sauna room power cord into the 15 amp 5 15R or 5 20R wall receptacle as noted in page 2 The Sauna Rooms is now ready to use Control Panel Instructions DR MERCO LA vraut sauna systems Main Power Press POWER to switch room ON or OFF Timer Functions Press and hold or to set room operating time Increases time 5 minute increments Decreases time 5 minute increments Temperature Functions 1 Press to alternate between either C or F C or F will light to indicate the units desired 2 Press and hold F or to set desired room temperature setting Pressing once will increase or decrease the desired setting in one degree increments The maximum temperature set point is 150 F 65 C e Once the desired room temperature set point will flash three 3 times e The fourth 4th flash remains lit and displays the actual room temperature 3 Press to turn Bench Heat ON or OFF Light Functions Note All Lights will operate with main power selection ON or OFF 1 Press Inside Light to turn ON or OFF 2 Press Outside Light to turn ON or OFF Color Therapy Functions Press Color Therapy Light to activate a color light or sequence The following details this sequence 1st press RED 2nd press RED GREEN 3rd press GR
7. nstallation of the room b Assembly Tools Phillips Screw Driver c Boxes are labeled in the order of room assembly Box 1 Floor Ceiling Bench Skirt Bench Fan Assembly Radio CD Player Manual amp Remote Control 10 Pack of Phillips screws for Junction Box Covers 4 Phillips screws for 2 person Sauna Wood Magazine Rack Box 2 Back amp Front Walls Wood Magazine Rack for 2 person Sauna only Box 3 Left amp Right Walls Electrical Requirements The IR Sauna Room is designed for a 120 Volt AC 15 Amp Circuit Breaker A 120 Volt AC dedicated circuit is recommended to avoid unnecessary tripping of the breaker The Sauna should be plugged into a NEMA 5 15R or 5 20R 1 Amp electrical outlet a l aL CE a 5 15R 5 20R Sauna Room Assembly Steps Note there are 11 total power connections 7 are located inside the Sauna Room Back Left Right Walls Bench Skirt Bench Skirt Fan Bench and Main Power Box 3 Power Connections are located on the Top Outside of the Ceiling 1 Sauna Room Power Cord Do NOT plug main sauna room power cord in electrical outlet until all required assembly steps have been properly completed There are 5 Power Connection Junction Boxes are labeled accordingly and should be made after each section assembly Back Left Right Bench Skirt Bench B1 to B1 L1 to L1 R1 to R1 S3 to S3 S1 to S1 These 5 Power Connections are easily made by simply pushing the white connector inside
8. ntraction occurs in the wood in a sauna environment This may result in minor cracks which is considered normal and not covered under any warranty Infrared Panels Electrical Controls and Temperature sensors are warranted for 5 years from date of original purchase Audio Visual devices Mercola will provide parts to replace with manufacturing or workmanship defects for a period of one 1 year from date of original purchase Commercial Use If the Mercola Vitality Traditional Saunas are installed in a commercial location such as gyms clubs condominiums apartments spas health practitioner s facility but not limited to these types of commercial businesses Mercola will provide all parts replacement for a period of one 1 year from the date of original purchase Thank you and enjoy the many healthy benefits of the Dr Mercola Vitality Saunas 12
9. the white Power Junction Box Cover onto the matching white Junction Box 3 pin connection Example below L1 to L1 Left wall power connection Left wall junction box Attaching Junction Box Covers After Junction Box connection has been made secure Junction Box cover with Phillips Screw Driver and 2 Phillips Screws provided in Box 1 Floor Panel Box 1 Locate the Floor Panel on a level surface 3 6 inches from wall and no more than 5 ft from 120 Volt AC 15 amp dedicated receptacle Position the Floor panel so that the Ceramic tiles IR Floor Heaters are to the front of the room Note store Ceiling Bench Skirt and Bench until the appropriate steps Back Wall Box 2 e Place Back Wall section into the back slot of the Floor Panel e Back Wall section must be held in place while Right Wall section is added e Connect the electrical connection power feed to the B 1 Junction Box e Secure the B 1 Junction Box cover with 2 Phillips screws Note Store Front Wall section until Front Wall Section step Right Wall Box 3 e Place Right Wall section into the right slot of the Floor Panel e Attach Back Wall to the Right Wall by lifting up the Right wall sliding into back wall bracket e Connect the R 1 electrical connection power feed to the R 1 Junction Box e Secure the R 1 Junction Box cover with 2 Phillips screws Left Wall Box 3 Place Left Wall section into the left slot of the Floor Panel Attach the Back
10. using the sauna Leave the Sauna and cool down Shower or bathe if possible to cool down and cleanse the skin Cool down period usually is the same length of time as the Sauna session Then reenter the Sauna for another 10 15 minute session Continue this process of alternating using the Sauna and Cooling Down for 3 to 4 cycles Length of time in the Sauna and cool off period varies and depends on the individual After final Sauna session and upon leaving the Sauna turn the Sauna off the timer if it is still operating Open the door and clean the Sauna walls bench and floor areas with a soft clean damp cloth Enjoy a final shower or bath to cool down Relax in the special after sauna glow and you may choose to enjoy a healthy snack and cool drink Additional Usage Warnings Located Inside Sauna Room 10 Maintenance General Cleaning Tips DO NOT USE Alcohol or any strong Cleaning Chemicals Note Some chemicals can damage clear finish and wood surfaces Interior Perspiration and dirt may absorb into the wood so periodic cleaning is needed scrubbing benches back supports floor boards and walls with a stiff brush and mild detergent is normally sufficient Light sanding is another option for cleaning interior surfaces Exterior Use a damp cloth of a mild soap mixed with warm water Trouble Shooting Tips a Flashing Screen Check to ensure ceiling room thermostat lead is connected properly found in the ceiling unit
11. wn below 2 person Sauna Front Wall e Attach the Front Wall to the Right and Left Walls by lifting up the Front wall and then sliding down into both the Right and Left wall brackets Note All wall sections will now be attached together and secure Ceiling Box 1 e Lift the Ceiling and gently place onto the four 4 walls as shown e Note Make sure the 3 electrical connections 1 front wall amp 2 rear walls are inserted through the ceiling and not being pinched as the ceiling is lowered into place e Make the 3 electrical control connections as shown e Close all ceiling top access panels Ceiling to Back Wall 2 Connections On the outside top left rear of the Ceiling lift the panel door You will see 2 connections labeled 1 amp 2 Attach each Ceiling 1 amp 2 connectors to the Back wall 1 amp 2 connectors Make sure they are securely attached together After 2 connections are made close the rear access panel Ceiling amp Front Wall Connection On the outside top front of the Ceiling lift the door You will see 2 power cords one from the Ceiling and one from the Front wall Attach the 2 power cords firmly together Close the access panel CD Player Mounting Screws Removal Located in the top of the Radio CD Player Remove the 2 SCIAWS ccc ecccccceccucucucuveueusucuvanens Wood Magazine Rack 2 Person IR Sauna Only Wood Magazine Rack is packed in Box 2 Wood screws are pac

Download Pdf Manuals

image

Related Search

Related Contents

HT 302-304 Italienisch  Casio MS-10VC Owner's Manual  Bedienungsanleitung  Guía de Configuración del Puesto de Acceso a los Sistemas  スニーク(Sneak)  Package Contents Charging the Unit Controls Indicators  Relais bipolaire à deux directions chaudière/pompe 24    LAPIZ DE RETOQUE 210 000  Scambio Termico 2008.pmd  