Home

4. Assembling the cover

image

Contents

1. OUV FERM OUV FERM 21 36 Installation instructions for the IMM Ax automatic immersed safety cover 5 2 Box without PLC screen 5 2 1 Electric connections 230 V AC 3 x2 5 mm 2x6 mm 3 x 1 5 mm Ouv Open Ferm Close Chlorinator 2x1 5mm 3 x 1 5 mm Installation instructions for the IMM Ax automatic immersed safety cover 22 36 Have the electric connections made by a qualified technician in 5 2 1 3 Connection box compliance with current standards Fig 53 Fix the transformer box in the technical room Plan M27 or M32 cable glands if you use the 2 x 10 mm Insta
2. IP X6 minimum Blue Brown Red 20 Installation instructions for the IMM Ax automatic immersed safety cover 20 36 20 5 1 2 Adjusting the run stops Switch on the box Press on A to activate the system Fig 47 Initialise by pressing 3 times on and then once on OK Fig 48 Indicate the motor position by placing yourself above the roller with your back to the pool Press once on if the motor is to the right Press once on if the motor is to the left Fig 49 Using the key unroll the cover and validate the position by pressing A once The PLC indicates that it has taken into account the position by displaying an M next to closed pos Fig 50 Using the key roll in the cover and validate the position by pressing B once when rolling in is complete The PLC indicates it has taken into account the position by displaying stop Restart the initialisation step Press 3 times on the key then on OK if you wish to reprogramme Invert the wires connected in the box on OPEN and CLOSE if the cover movement does not correspond to the OPEN CLOSE indications on the grey plate of the key switch
3. For models using solar power the batteries can remain in place if the solar panel is not covered and continues its charging function If the panel is covered and can no longer charge using sunlight the batteries must be disconnected and stored in a dry place When putting back into service let the batteries charge a half day of sunlight before operating the cover Safety instructions and user guide for automatic pool covers 6 8 6 Guarantee Our one year guarantee only covers the replacement or the repair of a defective part as well as all defects or faults in the context of the installation use maintenance and winterisation in compliance with our instructions It only comes into effect on the shipping date if the reseller or installer returns us the defective parts postage paid for analysis The guarantee covers all of the electrical equipment providing that the wiring was carried out in accordance with our instructions and in compliance with the standard C 15 100 The guarantee does not cover the immersion of motors not designed for this purpose and the consequences of lightning Apart from the general one year guarantee we grant the following guarantees sending the following guarantee form duly completed within 8 days of the slatted cover s installation gives a right for an extension of the geared motor guarantee from 1 to 3 years free of charge the roller mechanism 3 years 1 the cover s PVC slats 3
4. Handling the uncoupling of the roller mechanism should be read thoroughly before operation with the installation instructions 1 Switch off the box 2 Block the rotation of the shaft while keeping the slats rolled around 3 For the OPEN remove the housing on the motor side remove the OPEN PVC cap loosen the composite cover from the OPEN Solar Disconnect wires 1 2 3 and 4 of the motor cable in order to slide it completely towards the shaft and remove the unlocking ring 4 For the BANC remove the top cover and unscrew the butterfly screw from the housing inside the BANC Solar Disconnect wires 1 2 3 and 4 of the motor cable in order to slide it completely towards the shaft and remove the unlocking ring 5 For the IMM Box remove the key between the shaft and the motor or remove the motor 6 For the IMM Ax in the motor connection box located close to the pool disconnect the end of run stop wires and the power wires from the motor cable in order to slide the motor cable completely towards the shaft Remove the pin blocker to access and lift the unlocking pin 7 Manually accompany the unrolling of the cover making sure that the motor cable does not get entangled 8 Lock the safety mechanisms When commissioning the roller a new adjustment of the motor end of run stops will be needed This document is the property of AS POOL of the NextPool group and cannot be reproduced or communicated without our authorisat
5. Installation instructions for the IMM Ax automatic immersed safety cover 24 36 25 36 Installation instructions for the IMM Ax automatic immersed safety cover 6 2 Electric connection 6 2 1 Box Fig 61 230 V AC Chlorinator 3 x2 5 mm Connect the 230 V power cable to the terminal respecting the earth N and P symbols Connect the motor power wires of the connecting cable to the and terminals Connect the 4 connecting wires for the external sensor to terminals 1 2 3 and 4 Connect the treatment device to terminals 5 for the common 6 NO or 7 NC if you chose to use this function Connect the key switch wires to the C common O open and F close terminals 6 2 2 Key switch Fig 62 the wire connected to COMMON on the terminals marked 3 ashunt bridge between the two 3 terminals the wire connected to OPEN on one of the terminals marked 4 the wire connected to CLOSE on the other 4 terminal 6 2 3 Connection box Fig 63 Connect the external sensor by connecting the two brown wires together in the domino corresponding to wire 1 the two blue wires in the domino corresponding to wire 2 one of the black wires in the domino corresponding to
6. Fig 38 Secure the pool by pressing on the trigger 4 7 6 4 7 7 4 7 8 4 7 9 Fig 39 Before opening press on the lug and pull simultaneously upwards to remove the trigger Fig 40 Open the cover to disconnect the system Fig 41 Install the rear harpoon by jamming it in the female part of the last slat Fig 42 In the case of trapeze or roman stairs a strap is provided instead of the harpoon in the sloped or rounded areas Therefore you need to Unclick the two slats in the place provided make a two centimetre wide notch on the male part pass the strap through this notch taking care to leave a washer under the slat and clip the two slats The strap is blocked between the slats via these two end washers The upper washer is used for fastening in the Coverlock Installation instructions for the IMM Ax automatic immersed safety cover 16 36 17 36 Installation instructions for the IMM Ax automatic immersed safety cover 17 17 4 8 Fixing the apron to the shaft Fig 43 Fixing the cover to the shaft Place the strap fastener plates on the axis opposite the pre installed straps on the last slat place the loop around the strap fastener then fix it between the tube and the 30 x 80 black plate by tightening the screws Check that the gaps of the apron in the pool are evenly spaced on either side as soon as the rolling starts Correct the po
7. O Comments Observations 2 52 oe RG Ae ees Sec ea coc SS nee bated cb pate nace Dochenaherecaatansdaecdbai oh obs a a a ENNES AS Pool Telephone 33 0 811 901 331 postal address ZAC la Rouveli re 72 700 Spay FRANCE Fax 33 0 243 479 850 Safety instructions and user guide for automatic pool covers 8 8 Operational check SYMPTOMS A 1 The roller does not rotate 2 The apron rubs against the sides under the pool coping and on the separation 3 The cover does not roll completely or rolls too far L4 The cover does not unroll completely or unrolls too far 2 3 4 MAKE THE FOLLOWING CHECKS 230 V power supply to the electric box check the 10A 30mA ground fault circuit breaker The on off button on the box is ON Fuses are in good condition 24 V DC voltage on the motor power terminals when the key is turned Continuity of contacts of the key switch when the key is turned 24 V DC on the 2 motor power wires in the connection box when the key is turned The wire connections in the connection box are in good condition tight and not oxidised v Adjust the run stops The safety mechanisms are unlocked NISSEN ONESIES ISIS SEE v There are no objects in the pool that could prevent the correct operation The apron is centred v The water level is compliant with the recom
8. A slat apron A motorised roller shaft Two flanges to support the shaft A 23 x 32 cm box A slatted cover made up of a beam and duckboards if ordered A partition wall if ordered A fixture kit Installation instructions 7 36 Installation instructions for the IMM Ax automatic immersed safety cover 3 Assembling the roller 3 1 3 2 Necessary tools Fig 7 Plan the equipment necessary for assembly a perforator a set of flat spanners socket wrenches and hex keys a set of screwdrivers a mallet pliers a level a glue gun a cutter a multimeter a tape measure a saw an angle grinder and a marker Fitting the roller Warning at each step check that the roller can be installed horizontally on a level and square 3 2 1 Drilling the walls Fig 8 Use the flanges as a template to mark the fixtures using marks 1 and 3 to place the equipment Fig 5 Fig 9 Drill the wall horizontally according to the marking with 12 mm diameter holes of 70 mm depth using a wireless drill IMPORTANT the notion of wireless drill is HIGHLY IMPORTANT it means a battery operated drill 12 V A wire powered drill is connected to the mains i e to 220 V which is highly dangerous and strictly prohibited in this situation ie Installation instructions for the IMM Ax automatic immersed safety cover 8 36 3 2 2 Assembling the shaft and the flanges Fig 10 Assemble the mot
9. Installer details INE M CE eee Sree ee Seon ER SEEN eee COMPAQ Samecereerarececccee cs erer ceca seree sae ee cece cee er een reste Address RP RE Pere CREE Ep T ACA OSS se cacereccrcaseceestaessseceredtesetierscevnies tesctene tetstaretrecct ener ee Serial No Slatted cover type Slatted cover slat colour O MANU O BANC Classic O No Stress O White PVC O Transparent polycarbonate O OPEN One O BANC SURF System O IMM Ax O Sand PVC O Blue tinted polycarbonate O OPEN Classic O BANC Solar Energy O IMM Ax Solar Energy O Blue PVC O Blue tinted two ply polycarbonate O OPEN SURF System O IMM Box O DIVER O Grey PVC O Silver two ply polycarbonate Lloren solar Energy LIVEESIO L Marbled Blue Pvc Checks carried out on commissioning by the installer Signature and stamp mandatory write the words EM ECKS Cale d OUB DV RE Rene reece Te ome eT read ahdapproved Yes Checks carried out by Installation carried out in compliance with the standards in force according to the manufacturer s instructions 24 volt voltage slatted covers Presence of an automatic water level regulator slatted cover Presence of an independent overflow Rolling operation slatted cover Unrolling operation slatted cover Locking of the pool cover slatted cover Ce eee d EEG Gee g Installation without reserves COMIMISSIOMIM SEC AE D nn Safety usage upkeep and maintenance advice explained and sent to the responsible user O
10. an angle to the console in order to obtain a horizontal beam once the duckboard walkway isin place Amore accurate adjustment of the beam height is carried out using the bracket s oblong holes 4 and must maintain the bottom of the supporting brackets 4 cm above the water line 7 2 Fixture on the edges 7 2 1 7 2 2 Fixing the flanges to the edge Fig 68 Assemble the stainless steel fixing plate with the cover using the M10 nuts and washers Use the stainless steel supports as a template to mark the position of the 4 fixing holes on each side of the pool they must be carried out as close as possible to the pool depending on the structure s reinforcement elements Drill 12 mm diameter holes at a depth of 70 mm Manually screw the brass plugs to the TFHC M10x60 screws through the stainless steel plate Hammer the heads of the TFHC M10x60 screws using a mallet in order to insert them into the concrete belt Tighten and check that the fixtures hold If necessary used the supplied wedges to ensure that the edge plates are horizontal Fixing the sliders to the edge Fig 69 Assemble the stainless steel fixing plate to the slider using the stainless steel studs on the top part of the slider Use the stainless steel supports as a template to mark the position of the 2 fixing holes on each side of the pool Drill 10 mm diameter holes at a minimum depth of 60 mm Manually screw the brass plugs
11. check of the motor 32 1 Preparing the pool 1 1 Electric connections and cable passages 1 1 1 Electric box power supply Fig 1 230 V 50 Hz a Installation instructions for the IMM Ax automatic immersed safety cover 4 36 Consult the current electric standards and in particular NF C 15 100 3 x 1 5 mm Om lt 15m lt D 5x1 5 mm D lt 15m 2x6 mm D lt 30 m 2 x 10 mm Prepare a 230 V power supply using an R2V 3G2 5 mm or Ro2V 3G2 5 mm cable for the electric box which must be installed outside the volumes and O 1 2 2 Overflow Fig 3 Plan to control the water level at 12 cm below the edge and in a dry place technical room using a 50 mm overflow which is independent of the skimmers and automatic filling Take into account that when the cover is rolled in it will raise the water level by 10 mm 1 1 2 Electrical protection The power supply must be protected by a circuit breaker or a 10 A fuse holder and a 30 mA ground fault circuit breaker 1 1 3 Sheaths and cable passages Prepare a connection protected by a sheath for the 24 V DC power supply between the electric box and the box located by the roller using 2 x 6 mm if the cable is less than 15 m and 2x10 mm if the cable is between 15 m and 30 m long Prepare a connection protected by a sheath for the end of run stop management between the electric box and the box located close to the roller usi
12. from an incorrect connection a thunder storm or a defective component The box must be returned to AS POOL for analysis If the cover moves more than 1 metre the box is working correctly 8 2 Checking the power supply cable between the electric box and the roller motor 8 2 1 8 2 2 8 2 3 8 2 4 8 2 5 Reconnect the roller power cable to the box and disconnect it from the junction box Step by step measure the presence of the indicated voltage on the following terminals Connecting cable test 24 V DC on the electric box terminals marked and at the connecting cable connections Then 24 V DC on the terminals for the 2 wires arriving at the junction box If the voltage is below 22V this voltage will not be sufficient for the correct operation of the motor Check that the cable sections correspond to what is indicated on fig 1 the quality of the connections make sure of the continuity of the connections in the junction box and the box the absence of humidity or even water in the connection box Reminder the connection box must always be filled with gel If the voltage is not present or the value is different this means that your cable is defective cut damaged or has the wrong resistance or is located too near to a cable with a different voltage that disrupts its operation Replace the cable Make a temporary connection using another cable directly between the electric box and the motor to carry ou
13. sign the guarantee form attesting to the compliance of the installation the reception of the documents for the cover and the information given to the end user Installation instructi ctions for the IMM Ax automatic immersed safet y cover 34 36 11 Appendix diagnosis assistance tool Information MO when closing The value of the position between Troubleshooting Contact info LORS ooa Sensor error FM Seeder sain Arr t Surintensit 1 The screen permanently displays t also indicates the consumed intensity and the ounter in the closed position around 0 is 7000 and 8000 2 timer delays motor start When the poolis closed t of electric potential Cut off power resistive 0 0 5 at 30 VDC max The rev counter sign relaunch the system The motor has an uninterrupted po The action is suspen No actions can be carried out during this time Position Closed Open Intensity Status open or closed Rotational speed Warning message unted rotations when opening or counted down rotations rotational speed less than the value the number of co of the counter in the open up for half a second when the key is turned Command voltage present Power voltage present Motor light anti clockwise rotation Motor light clockwise rotation Motor forcing button in anti clockwise direction Motor forci
14. the number of slats on the pool or remove slats Uncoupling 6 4 1 Switch off the box 6 4 2 Block the rotation of the shaft while keeping the slats rolled around 6 4 3 In the connection box located close to the pool disconnect the power wires and from the motor cable in order to slide it completely towards the shaft The cable must be completely free from any constraints 6 4 4 Remove the pin block to access Turn the stainless steel pin a quarter turn so that it is perpendicular to the wall and pull The cover axis now rotates freely 6 4 5 Manually accompany the unrolling of the cover making sure that the motor cable does not get entangled 6 4 6 Lock the safety mechanisms 6 4 7 When commissioning the roller a new adjustment of the motor end of run stops will be needed 7 Accessories and options 7 1 Fitting an anti bending console Fig 67 Plana concrete belt using a 350 Kg cement per m concrete mix with a size of w 25 cm xh 40 cm x I 100 cm using at least 0 10 m to stabilise the fixture of the anti bending console Place the anti bending console on the edge and against the rear wall of the pool Mark the edges Install the arm 1 horizontally by correctly placing the vertical part of the bracket 2 against the pool wall 3 Install the wedges under the horizontal plate if there is a liner attachment rail for example or behind the vertical support to deliberately give
15. to the TFHC M8x55 screws through the stainless steel plate Strike the heads of the TFHC M8x55 screws using a mallet in order to insert them into the concrete belt Tighten and check that the fixtures hold The beam box is fitted to the slider using M8 nuts Installation instructions for the IMM Ax automatic immersed safety cover 28 36 Fixing the beam boxes to the edges Make sure that the height adjustment of the bottom of the duckboard corresponds to your needs The fixture to the edge of the 120 mm beam makes it possible to place this face 11 mm above the edge and up to 8mm The fixture to the edge of the 80 mm beam makes it possible to place this face 5 mm above the edge and up to 13 mm Assemble the stainless steel fixing plate to the vertical beam box support using the stainless steel studs in the upper part of the vertical support Use the stainless steel supports as a template for step 3 2 5 of the assembly and marking Make two fixtures on each side 7 3 Chemical sealing with inserts For M8 screws drill to a diameter of 14 mm and depth of 65mm For M10 screws drill to a diameter of 20 mm and depth of 70mm Clean the holes by blowing Inject a dose of chemical sealer and place the insert Respect the drying time indicated on the cartridge 29 36 Installation instructions for the IMM Ax automatic immersed safety cover 7 4 Positioning the fastenings for be
16. 1 2 Check the power relay operation 8 13 Disconnect the 2 wires connecting the box to the roller motor from the an terminals 8 1 4 Turn the switch on the box to On or 1 8 1 5 Check that the command and power diodes are on when the box is powered on 8 1 6 Step by step measure the presence of the indicated voltage on the following terminals 8 1 7 Electric box power supply test 230 V AC Alternating on the L and N terminals of the electric box to which the 230 V is connected 8 1 8 Transformer test 20 24 V AC between the red and blue jacks and 10 12 V AC between the White and Blue jacks exiting the transformer 8 19 Motor terminal tests 24 V DC between the and terminals of the motor when activating an open or a close 8 1 10 Terminal tests If there is a malfunction check that the cable terminals are correctly connected to the card 8 1 11 If a voltage is not present or a value is different check again making sure that the multimeter tips are in contact with the terminals and that your multimeter is calibrated and on the correct measurement position A voltage that is absent or different from the indicated voltage indicates that the tested component is defective Replace it or request its return to AS POOL for analysis 8 1 12 If the box is correctly supplied the fuses in good condition and if the cover does not move the box is no longer operational this can be due to a power surge
17. 14 Hammer the heads of the TFHC M10x60 screws using a mallet in order to insert them into the concrete belt Tighten and check that the fixtures hold Fig 15 Push aside the two flanges so that they touch the walls of the pool place the blocking ring against the drive ring of the tube then securely tighten the screws on it Check that the shaft is horizontal and if necessary adjust using the oblong holes on the bearing of the flange on the side opposite the motor Check the level of the shaft at each end using a tape measure measurement X1 should be equal to X2 Place the sliders and beam boxes Place the centre of the wall sliders using the F measurement plus 50 mm see page 5 Check using the beam box that the position allows the bottom of the duckboards to be level with the edge or the duckboard support and that it is correctly placed lengthwise Fig 16 Make the markings on the side of the pool Fig 17 Drill the sides at the markings using a 10 mm bit for a depth of 60 mm Place the TFHC M8x55 screws on the sliders 3 2 5 Install the partition wall and beam Fig 18 Manually screw the plugs on these screws to slightly extend the plugs Install the sliders and the beam boxes or only the boxes if the trench divide is in masonry Fig 19 Hammer the heads of the TFHC M8x55 using a mallet in order to insert them into the concrete belt Tighten the screws
18. AUTOMATIC IMMERSED SAFETY COVER IMM AX Installation instructions Please read carefully and keep for subsequent consultation Version 07 2013 K NOAD Abribluia Installation instructions for the IMM Ax automatic immersed safety cover 2 36 This instruction manual is intended for the person who installs and commissions an ABRIBLUE safety cover This manual must then be given to the pool owner along with the safety and user instructions so that it is available for subsequent use The advice given in this leaflet is taken from the experience of AS POOL ABRIBLUE with over 55 000 automatic covers since 1995 The advice will allow the user to make the best use of this product which should give compete satisfaction to its users Compliant with the highest requirements our safety cover was designed to prevent children younger than 5 years old from accessing the pool when it is unrolled and locked The floating safety cover is not a substitute for your common sense or your responsibilities It does not replace the vigilance of a responsible adult which remains the essential factor in the protection of young children Your retailer stamp 3 36 Installation instr
19. Adjust the height of the beam boxes depending on the height of the beam so that the lower side of the duckboards is level with the edge and that the duckboard is supported by the side support of the beam Fig 20 Assemble the side wall panels by clicking them together by placing them flat side by side and hitting them with a mallet protected by a wooden wedge from one end to the other Fig 21 Lower the partition wall into the pool Installation instructions for the IMM Ax automatic immersed safety cover 10 36 11 36 Installation instructions for the IMM Ax automatic immersed safety cover 150mm 40mm max min 3 2 6 Fig 22 Place the beam into the boxes making sure that the end of the beam can never have less than 4 cm on each box Fig 23 Slide the white cylindrical cabiclips of the bungee cords into the groove in the beam Thread the counterweights onto the bungee cords and spread them evenly over the width of the pool Check the length adjustment of the bungee cords so that the counterweights are at least 5 cm from the bottom of the pool when the cover is unrolled Installing the duckboards Carry out the electric connections the cover assembly and the end of stop adjustments before installing the duckboards Fig 24 Assemble the duckboard walkway so that each independen
20. ESTATION OF CONFORMITE 1 Safety Advice WARNING Paru AE 4 ATTESTATION DE CONFORMITE The pool can constitute a serious danger to your children Drowning happens very quickly Children close to a pool require constant monitoring and active supervision even if they can swim The physical presence of a responsible adult is indispensable when the pool is open Learn the actions that save lives Memorise the emergency service phone numbers and display them near the pool Fire Brigade 112 Emergency Services 15 This cover is not a substitute for common sense or personal liability Its aim is not to be a substitute for the vigilance of parents and or responsible adults which remains the essential factor in the protection of young children Be aware that safety is only assured with a closed locked cover which is correctly installed in compliance with the manufacturer s instructions The cover must be systematically unrolled and locked during absences however short from the home Check that there are no bathers or foreign bodies in the pool before activating the cover Keep the tools needed to activate the covers out of the reach of children Only a responsible adult should undertake to manoeuvre the cover It is prohibited to climb onto walk on or jump ona safety cover Take all necessary measures to prevent access to the pool by young children until the cover is repaired o
21. ake sure to position the harpoons and triggers in relation to one another to obtain perfect alignment and correct operation 4 7 1 4 7 2 4 7 3 4 7 4 4 7 5 Fig 34 Position each front harpoon on the male part of the last slat of the apron using two TFPZ 3x16 mm screws Once all of the necessary harpoons have been installed cut the remaining male part of the slat using a cutter and a metal saw This will protect the liner from any damage Fig 35 Fixing the triggers in the wall Mark out the holes by placing the part in the centre of the harpoon Drill to a diameter of 6 mm and depth of 35 mm Fix the part using the TRHC M5x30 mm screws and M5 brass plugs Make sure that this is horizontally level Fix the face on the part using the TRPZ 4x16 mm screws Fig 36 Option for fixing the triggers on the edge Fix the part on the support using the TFHC M5x16 mm screws and the M5 nuts Then assemble the support on the edge plate a using the TFHC M5x16 mm screw the whole forming an angle bracket Centre the whole on the harpoon then correctly flatten the support and the edge plate against the pool wall and edge Mark out the holes and drill to a diameter of 8 mm and depth of 35 mm Finally fix using the TFHC M6x30 mm screws and M6 brass plugs The front face of the trigger is fixed on the part using the two TRPZ 4x16 mm screws Fig 37 Close the cover to connect the system
22. ams Position 1 fastening level with the coating Liner fastening level with the coating beam support neoprene seal 80 mm beam Top position Bottom position 120 mm beam Top position Bottom position Installation instructions for the IMM Ax automatic immersed safety cover 30 36 Position 2 30mm ol Liner fi i fastening level with the coating beam support neoprene seal 80 mm beam 120 mm beam Top position Top position Bottom position Bottom position 31 36 Installation instructions for the IMM Ax automatic immersed safety cover 8 Test instructions in the event of a malfunction 8 1 The following list has been drawn up in order to help diagnose and correct malfunctions that may occur during installation This guide is exclusively for the professional authorised to install the cover in order to maintain the validity of the guarantee If after having followed these instructions the cause of the malfunction has not been found the professional must contact the cover retailer or manufacturer Read completely before carrying out the operations Refer to figures 25 and 27 Turn the switch on the box to Off or 0 before each connection disconnection operation Check the condition and the correct tightening of the electric connections Checking the box 8 1 1 Check that the fuse and the thermal circuit breaker are in good condition 8
23. d safety cover 6 36 2 Delivery and reception of the roller 0 2 11 2 12 2 0 6 11 6 12 6 9 2 1 9 6 1 2 1 Delivery Fig 6 Plan the presence of 2 to 6 persons or use a handling device to handle the cover The cover is delivered in a non recoverable wooden container measuring at least 40 cm more than the width of the pool It is heavy and fragile For a 4 x 8 m pool the container weighs 465 Kg and measures 4 6 x 0 6 x 0 8 h For a 5 x 10 m pool the container weighs 610 Kg and measures 5 6 x 0 6 x 0 8 h 2 2 Reception Open the container in the presence of the delivery staff and check the condition of the goods and their compliance Keep the original packing If there is any damage or missing parts write down your reserves on the transport documents e g container D open on delivery The words subject to unpacking alone are null and void Send a registered letter with acknowledgement of receipt to the transporter within 2 days This letter must give an exact description of the damage Send a copy of the letter to AS POOL for information Store the parts in the container which should not be left in full sunlight but should be placed in a cool place if the assembly is not carried out on the same day Make the inventory compared to the order Read the instructions completely before starting the assembly The installation requires 2 persons for 7 hours 2 3 Items in the container
24. etely free from any constraints Remove the pin blocker to access Turn the stainless steel pin a quarter turn so that it is perpendicular to the wall and pull The cover axis now rotates freely Manually accompany the unrolling of the cover making sure that the motor cable does not get entangled Lock the safety mechanisms When commissioning the roller a new adjustment of the motor end of run stops will be needed 6 Motor model with external mechanical sensors 6 1 Installing the external sensor system Fig 57 Before placing the duckboards install the sensor by sliding the support ring in the beam groove and position the counterweight behind the roller Fig 58 Place the sensor on the part of the apron that will roll up last e g if you have roman stairs place it in the middle Fig 59 Installation to be carried out Adjust the 2 support plates to reduce or extend the length as required and place the external sensor in the following position Warning the metal strip of the sensor bottom must never be in contact with the shaft This may cause the strip to pass in front of its detector and cause an unjustified run stop Fig 60 Fix the sheath attachment clips on the beam by pre drilling 3 5mm holes at equal distance Screw the clips directly using the screws provided Place the 2 cables of the detectors in the sheath and insert it into the clips The sensor cables must reach the connection box
25. fore any automatic action of the slats In the case of an emergency operation a person walking on the cover will have his her feet under the water Limit operating the cover when the temperature is below 5 C and do not handle the cover below 0 C when it is locked in ice Avoid all shocks and mechanical contacts on the slats when the temperature is below 0 C When the cover is installed on a sheltered pool make sure that the air temperature is no higher than 40 C Make sure that the surrounding air is ventilated in order to avoid all distortions and deteriorations of the parts PVC slats bench panels duckboards etc This document is the property of AS POOL of the NextPool group and cannot be reproduced or communicated without our authorisation 3 Upkeep advice The maintenance of the ABRIBLUE automatic cover is at the expense and under the responsibility of the user The use of an automatic cover maintains the quality of the water and reduces the amounts of treatment products needed Maintain a good water balance in order to avoid damaging your automatic cover Prolonged or repeated overdoses of products are damaging to the PVC slats An acid pH below 7 can corrode metal parts A lack of treatment causes the proliferation of algae and favours the putrefaction process which can cause the irreparable appearance of brown stains on the PVC slats Check the operation of the electrolyser when the pool is closed for
26. he double male hook into the female part of the preceding slat and then by pushing the slats up into a V shape towards the sky Make oscillating movements in order to cause click fitting along the whole length of the slat Checking the gap Fig 27 Place the cover against a length of the pool Check that there is a gap greater than 2 5 cm between the ends of the wings and the sides of the pool needed for operation and less than 70 mm otherwise the cover is no longer compliant Check that in the roller trench this gap between the flanges and the ends of the wings is at least 20 mm 10 15 20 25 and 30 mm wings are available on order Installation instructions for the IMM Ax automatic immersed safety cover 12 36 2 5cm lt x lt 7cm 13 36 Installation instructions for the IMM Ax automatic immersed safety cover 13 13 4 4 Placing the stair slats Fig 28 Centre the stair cover in its housing and assemble it with the rest of the cover To do this make two notches in the double male hook on the first slat of the apron on either side of the stairs in order to insert the caps of the base stair slat into the first slat of the cover Take care to not cut into the heart of the slat 4 5 Fixing the apron to the pool Fig 29 For IMM AX IMM AX S
27. ion 5 Winterisation advice Winterisation advice is described below however it is the installer s responsibility to recommend a solution depending on the availability of the customer and the geographical location of the swimming pool Carry out active winterisation by operating the circulation of the water and filtering during the coldest moments of the day An anti freeze thermostat can trigger filtering as soon as the air temperature falls below 0 Keep the water level normal excess water will drain from the overflow Clean the slats unrolled over the pool using a high pressure cleaner and then sweep the pool and the storage trench Treat the water with winterisation products Keep your cover unrolled over the body of water and if it is surrounded by a lot of vegetation fit a netting permeable cover over it in order to avoid the decay of leaves and other plant debris on the PVC slats Do not store the cover rolled with an accumulation of leaves or debris which would trigger an irremediable decaying process causing incrusted stains to form on the PVC slats This physical phenomenon is not covered by the guarantee for the slats Protect the skimmers and piping exposed to freezing Protect the motors from flooding Cut the power supply to the electric box Do not operate the cover or touch the slats when they are ice bound If there is a risk of the pool icing over have the immersed shaft and the roller motor removed
28. ll the key switch so that the cover can be controlled with a cable permanent view over the pool In the connection box connect the power and sensor Place the key switch cable gland towards the bottom wires strictly respecting the colour codes RED BLACK Turn the grey plate OPEN CLOSE as required WHITE BROWN and BLUE on the box card and the colours of the motor cable wires All the connections and disconnections must be made when the power is off Use the dominoes provided for these connections 5 2 1 1 Box When the cover is installed and the operating tests are complete fill the connection box with sealing gel to Fig 51 limit the oxidation of the connections which may cause In the box connect the 230 V power cable to the domino to the malfunctions x Li u Lu my tt LL LL left of the terminals respecting the L and N symbols The connection box must be 50 cm outside of the volume 0 In the box connect the motor power wires of the connecting see fig 1 and accessible at any time cable to the RED and BLACK terminals taking care to respect the colours of the motor cable wires In the box connect the motor sensor wires of the connecting cable to the terminals marked WHITE BROWN and BLUE taking care to respect the colours of the motor cable wires In the box connect the key switch wires to the Key terminals marked COMMON OPEN and CLOSE Connect the treatme
29. lling to the rear and breaking Do not operate the cover more than 15 consecutive minutes It is prohibited to manoeuvre the cover if there is a load on the duckboard walkway of an immersed cover this might cause the cover to scrape the beam Prohibit an overload on the duckboard walkway for an immersed cover due to the physical limits of the beam and the fixtures The duckboard walkway is supported by the pool edge and the beam and is designed to support a maximum load of 400 kg over its complete length duckboard included and 150 kg per linear metre Do not walk or jump on the covering of the BANC roller in order to avoid deforming it It is essential for safety reasons to remove the key from the control box or the manual wheel once the opening or closure actions are complete Programme the filtering system to start as soon as the solar slats are in sunlight During very sunny periods with the cover closed the water temperature can reach 30 or more and can damage the slats It is strongly recommended not to empty the pool without the authorisation of your installer If the cover is fitted with a WING System take care not to operate the cover without having folded the WING System onto the cover Operating the cover with the WING System deployed can cause major damage to the cover and the pool If the cover is fitted with a SURF System mobile roller make sure the roller is correctly positioned on the pool be
30. long periods This type of device cannot be fitted with a stop in production and can cause irremediable damage to submerged mechanisms corrosion in the event of a high concentration of stagnant chlorinated products in contact with the PVC slats To correct this situation occasionally air the pool water by opening the cover taking care to guard the access to the pool while it is open During a super chlorination operation roll up the cover start the filtering system and guard the access to the pool from children under 5 years old Clean your cover at least twice a year using a high pressure cleaner or a sponge using a descaling product and or a degreasing product water line gel type Do not use a solvent or abrasive product as these may damage the PVC slats Do not spray water onto the shaft as this might damage the motor During the summer period clean the slat storage trench once a month using a manual vacuum brush Regularly remove any debris lying on the cover Check the correct operation of the water level regulation overflow not clogged automatic filling correctly set Make sure that the area where the cover motor is located is fitted with a drain preventing the motor from being immersed at all times in case of flooding Safety instructions and user guide for automatic pool covers 4 8 Check that the slats are not subjected to temperature differences greater than 15 between the outside air and the water in order t
31. mended level and is constant The sides of the pool are level and parallel The slat apron is attached to the shaft SARASA v No slats are damaged or out of alignment SERVICING OF THE EQUIPMENT Description of the work Product Company Address Tel Fax ss Q NED Abriblue COVER Range AS POOL zac de la Rouveli re F 72700 SPAY LE MANS 33 0 811 901 331 33 0 243 479 850 contact abriblue com www abriblue com j
32. metic tarpaulin this would risk creating a major heating effect greenhouse effect which could cause the slats to warp permanently Check the good condition tightness and correct fixture of the safety loops Check that the straps linking the slats to the shaft are always tightly in place and evenly distributed Check the ends of the slats check that they are aligned and that the caps and wings are not broken A slat not aligned with the rest of the cover could jam when the cover is moving and cause major damage This document is the property of AS POOL of the NextPool group and cannot be reproduced or communicated without our authorisation 5 8 Safety instructions and user guide for automatic pool covers 4 Maintenance advice In the event of a malfunction or a repair preventing the closure and the securing of the pool take all necessary measures to prevent the access to the pool of children under 5 years old AS POOL ABRIBLUE only distributes its technical products via a network of pool professionals which carries out the installation and follow up depending on the specificities of the pool AS POOL ABRIBLUE does not communicate directly with the pool owners Have the automatic cover serviced by a swimming pool professional we recommend your swimming pool installer whose details are on the cover of this manual who will be able to contact our technical assistance department All spare parts must be original spare par
33. nd disconnections must be made when the power is off Fig 45 5 1 1 1 Box In the key switch connect Fig 44 the wire connected to COMMON on the terminals marked 3 In the box connect the 230 V power cable to the domino to the left of the terminals respecting the Le t and N a shunt bridge between the two 3 terminals symbols the wire connected to OPEN on one of the terminals In the box connect the motor power wires of the marked 4 connecting cable to the RED and BLACK terminals the wire connected to CLOSE on the other 4 terminal taking care to respect the colours of the motor cable wires 5 1 1 3 Connection box In the box connect the motor sensor wires of the Fig 46 connecting cable to terminals 1 2 and 3 marked WHITE Plan M27 or M32 cable glands In the connection box connect the power and sensor wires strictly respecting the colour codes RED BLACK WHITE BROWN and BLUE on the box card and the colours of the motor cable wires Use the dominoes provided for these connections When the cover is installed and the operating tests are Ouv Open complete fill the connection box with sealing gel to De limit the oxidation of the connections which may cause Com 24V Ge Se malfunctions 3 4 wea The connection box must be 50 cm outside of the volume 0 see fig 1 and accessible at any time De Ca Ferm Close
34. ng 5 x 1 5 mm Prepare a connection protected by a sheath for the control between the electric box and the switch using 3x1 5mm Separate cables carrying different voltages 24 V and 220 V by passing them through different sheaths which are spaced in compliance with NF C 15 100 go ss Li eerten box Q outside volume zero and less than one metre from the pool 1 2 Building work 1 2 1 Concrete belt Fig 2 Plan a concrete belt using a 350 Kg cement per m concrete mix with a size of w 40 cm x h 50 cm x 150 cm using at least 0 30 m3 to stabilise the fixture of the roller 5 36 Installation instructions for the IMM Ax automatic immersed safety cover HE 5 1 2 3 Skimmers When possible plan to place the skimmers on the pool widths and not on the lengths in order to facilitate the movement of the cover 1 3 Fitting the roller 1 3 1 Size of the trench Pool lengthinm D Roller diameter F Minimum width mm of the technical Shaft included trench 4 420 480 5 440 500 6 460 520 7 480 540 8 500 560 9 530 590 10 560 620 C Duckboard 11 580 640 12 590 650 13 620 680 14 640 700 15 660 720 Fig 4 Define the minimum width F of the roller trench using the following method e Determine the inner width allo
35. ng button in clockwise direction auPWNE contact is open These contacts are free he info LED is on the NO contact is closed the NC 0 2 Aat 125 Vac load 0 3 A at 125 v 1 Aat 30 VDC inductive load 220 VDC ERROR MESSAGES voltage 250 Vac al remains in the same status The system jams Only a new reset can Check the sensor connection wer supply for 5 minutes ded and the motor is stopped for 20 seconds The electrical circuit breaker has stopped the motor operating intensity greater than 10 A On the same open or closure cycle if this error occurs three times this display will flash showing the screen opposite To reset the system press the control box On Off switch 35 36 Installation instructions for the IMM Ax automatic immersed safety cover _ D 4 Q r iblue Installation instructions for the IMM Ax automatic immersed safety cover 36 36 Product Company Address Tel Fax IMM Ax AS POOL ZAC de la Rouveli re F 72700 SPAY LE MANS 33 0 811 901 331 33 0 243 479 850 contact abriblue com www abriblue com Compliance certificates Safety instructions and user guide for automatic pool covers 2 8 1 Safety Advice 2 2 Advice for Use 3 3 Upkeep advice nee 4 4 Maintenance advice 5 5 Winterisation advice 6 6 Guarantee ooeec 6 A5 CNE E TARY i ATTESTATION OF CONFORMITE eS AE ATT
36. nt device to the Chlorinator terminals marked NO NC and COMMON if you chose to use this function 5 2 1 2 Key switch Fig 52 In the key switch connect Com 24 V de the wire connected to COMMON on the terminals marked 3 ashunt bridge between the two 3 terminals the wire connected to OPEN on one of the terminals marked 4 Ferm Close the wire connected to CLOSE on the other 4 terminal IP X6 minimum 23 36 Installation instructions for the IMM Ax automatic immersed safety cover OUV FERM OUV FERM 5 2 2 Adjusting the run stops 5 3 Fig 54 55 56 Switch on the box Switch the box s switch to Manual Using the control key activate the cover and check that the direction of rotation of the shaft corres
37. o prevent them from warping case of a highly heated pool in a cold environment mountain for example When using a cover installation under a shelter make sure the shelter is aired and limit its temperature to 40 C maximum and prevent the slats and bench panels from overheating Protect wood elements such as duckboards and bench panels Wood whatever its origins is subjected to the aggression of the environment on a daily basis walking bad weather dampness or dry weather It therefore needs a minimum of maintenance Prefer a wood saturator For it to be efficient we recommend that you apply it using a brush until saturation in order to stabilise it and avoid tannins from being rejected The coats must be applied when the previous coat is still damp without any drying time between them 2 or 3 coats according to the porosity Avoid wax or silicone based products they are very quickly decomposed by UVs and washed away in bad weather Depending on climatic conditions exotic woods become silvery grey over time Avoid varnishes and surface coatings they form unstable films which are subject to flaking We recommend the products Durieu DESKS OLJE D1 mentioned in the Techniques PISCINES review for the maintenance of exotic woods If you have tannin stains on your pool copings or protective cover we recommend the application of concentrated bleach using a brush followed by copious rinsing Do not cover the opaque slats with a her
38. olar Energy IMM BOX VEESIO NO STRESS BANC Classic and BANC Solar Energy slatted covers place the safety systems only on the width opposite the roller However for the MANU OPEN One OPEN Classic OPEN Solar Energy OPEN SURF System BANC SURF System and DIVER slatted covers place the safety systems on both widths of the pool i e on the roller side and the side opposite the roller 4 6 Fixing the anti lifting buckles 4 6 1 4 6 2 Fig 30 amp 31 Fix the female loops on the sides 40 mm above the water line opposite the anti lifting mechanisms pre installed on the slats Fig 32 amp 33 Option for fixing to the pool edge fix the bracket support into the concrete belt under the coping applying the bracket against the pool side Carry out a clipping and unclipping test on all mechanisms Tighten the straps to press flatten the slats against the wall and provide good pool safety All of the anti lifting devices must be unlocked to handle the cover and adjust the run stops Installation instructions for the IMM Ax automatic immersed safety cover 14 36 15 36 Installation instructions for the IMM Ax automatic immersed safety cover 4 7 Fixing with the Coverlock system M
39. orised tube to the flange at the opposite end of the motor following these steps e fit the stop ring to the bearing shaft which is used to stop the bearing shaft from sliding e fit the black bearing to the bearing shaft e place the 8 mm pin onto the shaft and slide the black bearing to hold it by covering the pin and the end of the shaft e fix the black bearing to the bearing flange using M10 nuts Thus the pin is trapped in the black bearing against the flange Fig 11 Assemble the motorised tube with the flange on the motor side by inserting the motor end into the conical black bearing Pin the motor end to the bearing shaft using the pin stainless steel ring diameter 10 mm making sure that the pin crosses the motor shaft completely Pass the motor cable behind the central embossing of the flange between the pin and the pool and bring it out in the upper part of the embossing Position the pin block Place the TFHC M10x60 screws Manually screw the plugs on these screws to slightly extend the plugs 3 2 3 Installing the roller Fig 12 Slide the bearing shaft into the tube to shorten the whole Fig 13 Lower the assembled roller into the pool 9 36 Installation instructions for the IMM Ax automatic immersed safety cover 3 2 4 Fig
40. ponds to the request The slats must always pass over the shaft In the box invert the motor power wires connected on the red and black terminals if this is not the case Switch the box s switch to Auto Initialise the programming by pressing the yellow push button approx 5 seconds and releasing when the LED flashes Using the control key completely roll in the cover The key can be turned several times during opening to adjust the cover to the optimum position the key can be released then turned again during opening The position of the Opening run stop is stored in memory while turning the key during Closing Validate this position by closing the pool using the control key Unroll the cover The key can be turned several times during closing to adjust the cover to the optimum position the key can be released then turned again during closing The position of the Closing run stop is stored in memory while turning the key during Opening Validate this position by opening the cover using the key Once the pool is open close it again The end of run stop adjustment is complete Uncoupling Switch off the box Block the rotation of the shaft while keeping the slats rolled around In the motor connection box located close to the pool disconnect the sensor wires and the power from the motor cable in order to slide it completely towards the shaft The cable must be compl
41. r when a malfunction prevents the closure of the cover to secure the pool or if the pool equipment is temporarily unavailable Comply with the water levels defined by the manufacturer This document is the property of AS POOL of the NextPool group and cannot be reproduced or communicated without our authorisation 3 8 Safety instructions and user guide for automatic pool covers 2 Advice for use Always check that the pool water level remains constant and in compliance with the manufacturer s recommendations 12 cm as a standard before using the cover in order to avoid jamming the slats in the trench against the beam or the partition wall or to prevent them from rubbing against the pool copings or to avoid the slats being warped by excess or insufficient water levels Make sure that the overflow and the water level regulator are operational so that the skimmers do not suck in air if the water level is too low Remove all floating objects that could hinder the correct operation of the ABRIBLUE cover during its closure and lock the access to the pool using the blocking straps Do not forget to unlock the safety mechanisms before opening the pool cover as failure to do so may damage the pool cover Always keep the pool in full view during the opening and closing operations It may be necessary to accompany the cover manually during rolling or unrolling operations in order to position it correctly if there is a strong side
42. sition of the strap fixtures if the spacing is not even Finish the adjustment of the end of run stops once the cover s slats have been assembled Check the length adjustment of the bungee cords so that the counterweight does not touch the roll of slats when rolled in and does not touch the bottom of the pool when rolled out Installation instructions for the IMM Ax automatic immersed safety cover 18 36 5 Motor model with internal programmable sensors 5 1 Box with PLC screen 5 1 1 Electric connections Chlorinator Noir Black Rouge Red 230 V AC 3x 2 5 mm 2x 1 5mm 3x1 5 mm 3 x 1 5 mm 19 36 Installation instructions for the IMM Ax automatic immersed safety cover 19 19 Have the electric connections made by a qualified BROWN and BLUE taking care to respect the colours of technician in compliance with current standards the motor cable wires Fix the transformer box in the technical room In the box connect the key switch wires to terminals 4 5 Install the key switch so that the cover can be controlled and 6 marked COMMON OPEN and CLOSE with a permanent view over the pool Connect the treatment device to terminals 7 or 8 and 9 Place the key switch cable gland towards the bottom marked NO NC and COMMON if you chose to use this function Turn the grey plate OPEN CLOSE as required 5 1 1 2 Key switch All the connections a
43. t element weighs at least 10 Kg part approx 1 m e Wooden duckboards are assembled side by side using the cylindrical plugs e Aluminium duckboards are assembled by longitudinal threading and are blocked using the headless screws e PVC duckboards are clipped together by striking the side with a mallet and a wooden wedge when they are laid side by side from one end to the next e When the cover is installed and the operating tests are complete fill the connection box with sealing gel to limit the oxidation of the connections which may cause malfunctions 4 Assembling the cover 4 1 4 2 4 3 Special care needs to be taken when handling the slats A shear strain on them can cause irreversible damage to the caps this is why they must not be assembled by threading Placing the slats on the water Fig 25 Transfer the slats directly from the container to the pool water avoiding all mechanical contacts Prevent the slats from rubbing against the ground Place the packets of slats directly onto the water curved side towards the sky and the double male hook on the side opposite the roller Place the specific groups of slats the group fitted with straps to hook to the shaft on the roller side the group fitted with the other anti lifting mechanisms on the side opposite the roller and the slats for the stairs Assembling the packets of slats Fig 26 Assemble the slats by clipping them together by inserting t
44. t new tests 8 3 Checking the key switch 8 3 1 8 3 2 Use the continuity measurement of your multimeter to check that the contacts NO located behind the switch close one after the other when the key is turned first in one direction and then in the other In the box Measure 24 V DC between the com and the open when the key is on open Measure 24 V DC between the com and the close when the key is in the close position 8 4 Direct check of the motor 8 4 1 8 4 2 If the cover does not move check the motor sensor operation return data by checking e the good condition of the motor cable e the correct placement of the stainless steel blocking ring against the roller tube so that the flanges are correctly flattened against the pool walls If these elements are correct the motor sensor is out of order this can be due to a power surge related to a faulty connection a storm or a defective component The motor must be returned to AS POOL for analysis Installation instructions for the IMM Ax automatic immersed safety cover 32 36 33 36 Installation instructions for the IMM Ax automatic immersed safety cover 9 Checks Check the following points relating to standard NF P 90 308 and check that the cover operates correctly e When turning the key switch for the cover the entire pool is visible and check that there are no bathers in the pool when closing the cover The unrolling operation stops when
45. the key is released The key can be removed from the control box e The cover rolls and unrolls correctly e The safety mechanisms are easily handled for the recommended water levels and are sufficient number and position Check that they are locked on completion of the installation e The gaps along the length between the slats of the apron and the pool wall are less than 7 cm and the apron does not rub abnormally against the wall e The slatted cover duckboards is stable and resists intrusion and lifting by a force of less than 50 N e The space between the bottom of the beam supporting the duckboards of an immersed cover and the partition wall is 150 mm maximum e The gap at the bottom of the partition wall and the bottom of the pool is less than 100 mm e The voltage powering the cover is less than 30 V DC e The end of runs stops if they exist operate e The site is cleaned after installation of the cover and the packaging and waste is removed e The user manual has been given to the end user e The cover s guarantee form is filled in and signed 10 Reception of the cover by the end user e The installer explains the operation of the ABRIBLUE cover to the end user and informs him her of the safety usage upkeep and winterisation advice e He gives him her the cover s instructions e He demonstrates the use of the cover and shows the functional limits of the cover The installer and end user fill in and
46. ts in order to maintain our guarantee and the cover s compliance with the standard Carry out a complete revision of the cover once a year Whenever used the cover should be inspected to identify damage that may compromise its correct operation A professional will diagnose whether some slats need to be replaced Check that the upkeep advice is applied and that the user carries out his checks regularly Otherwise go over them item by item Check that the coupling nuts are tightened that the stop ring and all the screws are present on the axis Check that the electric connections are tight and operate correctly Make sure there is no humidity or oxidation on the cover s electric contacts terminals in the box box connections contacts of the key switch Check the condition and the ageing of the locking mechanisms and the bungee cords used to retain the PVC slats Check that the straps are tight on the axis Check the correct operation of the filtering system the overflow and the water level regulator Carry out several rolling and unrolling tests to make sure the cover is operational and especially to check that the end of run stops are correctly placed When the system does not respond your installer can secure the pool by uncoupling the cover roller and manually unrolling the cover onto the pool before locking the safety mechanisms on the pool cover In this situation the pool cannot be used until the cover is repaired
47. uctions for the IMM Ax automatic immersed safety cover 1 Preparing the pool 9 Checks 10 Reception of the cover 1 1 Electric connections and cable passages 1 2 Building work 1 3 Fitting the roller by the end user 2 Delivery and reception of the roller a 11 Appendix diagnosis assistance tool 2 1 Delivery 2 2 Reception 2 3 Items in the container 3 Assembling the roller 3 1 Necessary tools 3 2 Fitting the roller e N NN nn OD np A 4 Assembling the cover 2 4 1 Placing the slats on the water 12 4 2 Assembling the packets of slats 12 4 3 Checking the gap 12 4 4 Placing the stair slats 13 4 5 Fixing the apron to the pool 13 4 6 Fixing the anti lifting buckles 14 4 7 Fixing with the Coverlock system 15 4 8 Fixing the apron to the shaft 17 5 Motor model with internal programmable sensors 5 1 Box with PLC screen 18 5 2 Box without PLC screen 21 5 3 Uncoupling 23 6 Motor model with external mechanical sensors 6 1 Installing the external sensor system 24 6 2 Electric connection 25 6 3 Testing the run stops 27 6 4 Uncoupling 27 7 Accessories and options 7 1 Fitting an anti bending console 28 7 2 Fixture on the edges 28 7 3 Chemical sealing with inserts 28 7 4 Positioning the fastenings for beams 29 8 Test instructions in the event of a malfunction 8 1 Checking the box 31 8 2 Checking the power supply cable between the electric box and the roller motor 32 8 3 Checking the key switch 32 8 4 Direct
48. wind a free form pool or a pool with a specific configuration It is imperative not to halt the cover in an intermediate position this can cause the risk of jamming a bather s body at the level of the cover casing if a bather uses the pool The person carrying out the action must make sure there are no bathers in the pool before starting Check that the hose or power supply cable of the pool cleaner does not get tangled in the cover this could jam the operation of the roller and damage the PVC slats Check that unrolling and rolling runs correctly over the first few metres the slats roll effortlessly there is no jamming on the shaft with the top bulging towards the outside of the roll and if necessary stop the action immediately in order to intervene on the cause of the malfunction The rotational speed of the shaft is not constant due to the rolling unrolling of each new layer of slats which unbalances the roller Adapt the wheel s rotational speed on the manual model in order to avoid the harder spots by handling the wheel with both hands It is imperative during rolling or unrolling operations not to release the key until the end of run stops have been reached especially on the BANCS in order to correctly position the slats on the shaft when rolling in is complete or on the water when unrolling is complete On the model without run stops make sure not to roll in the slats too much in order to prevent them from fa
49. wing the complete rolling of the cover using the table Take into account the radii circular cuts and the thickness of a masonry partition wall that is wider than the beam which would be unusable zones for fitting the cover e Check that If there is a duckboard laid on the edges of the pool F lt Duckboard in mm 25 mm In the case of a duckboard covering the beam and laid on the edge F lt Duckboard 25 mm 100 mm If a duckboard is not laid on the rear edge F lt Duckboard overlap of the coping 1 3 2 Squaring checks Fig 5 In order to correctly place your roller perpendicular to the pool lengths measure the diagonals Make a mark 1 on the pool liner at the level of the edge at the centre of the rolling trench Measure a precise length A of 1 m less than the length of the pool and make a mark 2 at the end of A on the pool liner On the opposite length make a mark 3 opposite mark 1 Carry over the A measurement from 3 in order to place mark 4 Measure the distance B1 between 1 and 4 and measure the distance B2 between 2 and 3 If B1 and B2 are equal continue with the next step otherwise correct the position of marks 3 and 4 and start the operation again until B1 B2 6 Installation instructions for the IMM Ax automatic immerse
50. wire 3 and the other with domino 4 Connect the motor power wires strictly respecting the colour codes Red and Black The connection box must be 50 cm outside of the volume 0 see fig 1 and accessible at any time Installation instructions for the IMM Ax automatic immersed safety cover 26 36 Com 24 V dc Ouv Open Ce cae Ferm Close 4 O O Black 2 O Blue Blue O Brown Brown 1 O O Black 3 Red O O O O Black 27 36 Installation instructions for the IMM Ax automatic immersed safety cover 6 3 6 4 Testing the run stops Operation Fig 64 Cover in open run stop position The first slat of the apron has passed the top sensor strip it falls and is therefore not in front of its detector Opening of the system stops Fig 65 The cover starts operating again during closing The apron unrolls on the pool Fig 66 Cover in closed run stop position The last slat of the apron has passed the bottom sensor strip it falls and is therefore not in front of its detector Closing of the system stops Warning if closing is incorrectly stopped cover stopped too soon there is a space over the pool cover stopped too late the slats are compacted and lift up from the surface of the water Adjust
51. years 2 solar panel 10 years batteries 1 year 1 The guarantee covers the resistance of the materials used with the exception of corrosion and deterioration of certain materials due to the use of any device producing an electro chemical or electro physical reaction which generally accelerates the corrosion of metals 2 The guarantee covers the buoyancy watertightness and articulation of the slats The guarantee does not cover brownish stains and discolouration of the slats Distortion of the blue translucent solar slats caused by use in disregard of our technical recommendations is also excluded Damage caused by hail is excluded All modifications to a slat voids the guarantee on the apron All labour costs for removal assembly travel water supply products damages and interests as well as any claims for compensation for any cause whatsoever are excluded This document is the property of AS POOL of the NextPool group and cannot be reproduced or communicated without our authorisation 7 8 Safety instructions and user guide for automatic pool covers Guarantee form The official guarantee is in the slatted cover s container with the commissioning documents This guarantee must be returned to the address below within eight days of the commissioning of the product It gives the right to an extension of the guarantee for the Abriblue slatted cover motors to three years as from the commissioning date User details

Download Pdf Manuals

image

Related Search

Related Contents

Gama UBxx  manuel de service du vehicle tracking system  Catalog - Newtunings.com  LG HT805PH home cinema system  Benjamin Sabatier  Operating instructions for condenser tumble dryer T 7944 C  取扱説明書 設置工事編  intralux 5100 User`s Manual  

Copyright © All rights reserved.
Failed to retrieve file