Home

FHF InduTel GSM User Manual

image

Contents

1. EMC Quiche ire nonionic cee cce cee eeseeseeseenecsseseesseesceneseceucsecesseneeseesesseeeneeneeeeeees 12 General operating instructions 1 The Indutel GSM is intended for use with a solar panel or a DC voltage of 5V An internal battery serves as a voltage buffer At least one SIM card is required for operation The SIM cards must have their PIN request deactivated The telephone has a receiver hook with a contact magnet as hook switch To end a phone call the receiver has to be placed back Telephone settings are programmed by sending information via SMS to the Indutel GSM Successful completion of programming is confirmed via a return SMS When the solar panel is in operation the panel must be oriented in such a way that sufficient charging of the battery is ensured The battery discharge status is reported via SMS to the number pre programmed for this purpose When receiving calls the Indutel GSM will ring at a volume and with the melody programmed by you When programming the device settings the four digit alphanumeric password must be within the SMS text This password can only be changed via SMS If you forget your password please contact our technical support team A warranty period of 24 months applies from the date of purchase If you experience technical problems please contact our technical support team in Germany located in the city of Muelheim an der Ruhr Telephone 49 0 208 82 68 102 Fax 49 0 208 82 68
2. attempts to dial into the GSM net of SIM card 1 If this is unsuccessful it will attempt to dial into the net of the second SIM card SMS text FHFO000 FHF SIMCHK SIM1 NOR The telephone first attempts to dial into the GSM net of SIM card 2 If this is unsuccessful it will attempt to dial into the net of the first SIM card SMS text FHF0000 FHF SIMCHK SIM2 NOR Programming emergency numbers SMS text FHFO000 FHF TNUM1 49 In an emergency the programmed phone number receives an SMS such as FHF000000 ALARM VBAT 3 41 In this instance the message says that battery voltage has fallen below a reliable value and the GSM module in the telephone will be switched off Restoring default settings SMS text FHFO000 FHF amp LDEFAULT When restoring default settings the PIN will not be set back to 0000 Changing the telephone ID number default setting 000000 FHFOO00 FHF SN value Changing the password SMS text FHFO000 FHF PSW new password Saving the new parameters After setting the parameters listed above the following SMS must be sent to ensure that those values are saved FHFO000 FHF amp W Serial port RS485 Communication protocol for connecting with an extemal device Sending The Indutel GSM sends STX start of text 02 hex The Indutel GSM waits for DLE data link escape 10 hex If a NAK negative acknowledgement or any other signal is sent back as a DLE or there is a timeout sending is r
3. label If the intemal battery needs to be exchanged you will receive an appropriate replacement battery from FHF including installation instructions Care and maintenance The telephone is maintenance free Nonetheless in areas of operation that are heavily exposed to dirt such as dust fats oils etc cleaning should be carried out from time to time Use a moist cleaning cloth to wipe down the apparatus and the receiver Careful Never use pointed objects to clean the phone Please avoid using other cleaning or scrubbing agents Adjustable casing components must NOT be brought into contact with grease or lubricants e g fats and oils Warnings and safety instructions This device is a weatherproofed telephone made especially for operation in the rough conditions of an industrial environment The following wamings and safety instructions are to be observed 1 The IP 66 protection rating is only guaranteed when the casing is closed 2 The telephone is intended for operation connected to a solar panel or DC voltage The recommended voltage range is to be adhered to Correct polarity connections are to be observed Connecting cables are to be positioned in such a way as to eliminate accident risk 3 The telephone may only be operated under the environmental conditions indicated see Technical Fact Sheet Adverse environmental conditions such as extremely high or low air temperatures are not acceptable because they promote failure
4. of the telephone s electronic components 4 Ensure that the telephone the connecting cable etc are not damaged Operation of the telephone is not acceptable in damaged condition 5 When operating the telephone statutory and commercial guidelines accident prevention guidelines as well as electrical regulations are to be observed 6 Forall repairs only original parts are acceptable which must be installed by a qualified repair person Other kinds of replacement parts can cause damage The guarantee is voided 7 Prior to a repair or replacement of the telephone the voltage supply must be disconnected The internal battery must also be disconnected If maintenance or repair under voltage is unavoidable only qualified personnel may cany it out 8 The sealing elements necessary to ensure the casing is sealed must not be damaged during assembly and disassembly 9 The recommended operating position wall mounted is to be observed 10 Changes to this product that serve as technical improvements may be made without prior notice 10 11 Technical fact sheet GSM frequency bands Voltage supply Solar panel Maximum power supply Battery Nominal voltage Standard capacity Temperature range charging Temperature range discharging Operating time Talk time Standby Operation Ringing volume Casing Height x width x depth Weight telephone incl telephone holder Operating position Receiver Speaker capsu
5. 377 Email info fhf de If a fault cannot be fixed over the phone please send the apparatus and all accessories as well as a copy of the purchase receipt to the following address FHF Support Indutel Gewerbeallee 15 19 45478 Muelheim an der Ruhr Germany Original condition Telephone default settings Password 0000 Call melody 3 Call volume 5 Receiver volume 4 Microphone sensitivity 4 The default settings can be restored at any time via the programming function This will not however change the new password Assembly and Installation Wall mounting Attach the mountings to the telephone using two screws for each Use the M5 x 8 mm countersunk screws supplied Fasten the telephone with four screws up to 8 mm in diameter to the wall Serial port connection Take off the key touchpad together with the handset Connect the positive battery connector red cable to clamp 9 Solar panel or voltage supply connection Push the solar panel cable or DC voltage supply cable through a cable fitting and put the end of the cable onto clamp 5 and 6 Note Observe polarity Only use a cable with a cladding diameter between 5 mm to 9 mm otherwise the protection rating of IP 66 is not guaranteed SIM cards Please insert the SIM card necessary for operation into one of the SIM card holders If operating with two SIM cards please insert both SIM cards into the SIM card holders The SIM cards must have their PIN request deactivat
6. Weatherproof GSM telephone IND UTELGSM M lew til p IIP FUNKE HUSTER FERNSIG 2 FHF BA 9605 50 12 09 Please note Please read this user manual thoroughly before installing the device Check that all component parts were delivered Table of contents General operating instructions 2 esses eceeeeeeeesteeteeeeeees 3 Original condition 4 Packaging content w 4 Telephone default settings 20 2 eceeeceesceeseeeeeeeeeeeeeeaeeeteaeeeeseeeeeeaueeeeesaeeeetiaeeetenaeees 4 Assembly and Installation Wall mounting 4 Battery connection 4 Solar panel or voltage supply connection 4 SIM cards 4 Seral Port GOMNSCHOMs sssr heria aa aa e iaaa aa a aa eea i ines 5 Operating instructions 6 Control elements 6 Key touchpad 6 Making receiving calls 6 Dialing 6 P o tammMiN g ienes nomni e akn 6 Setting call volume eA Setting call melody 7 Setting speaker microphone sensitivity 7 Setting call reception volume 05 Pa Programming priority settings for SIM cards 8 Programming emergency numbers 18 Changing the password 8 Restoring default settings 8 Serial port RS485 02 0500 eee eee ee 9 General instructions Service Care and maintenance Warnings and safety instructions 10 Technical fact sheets2 c ccs c anena E E 11 Conformity declaration on cce cece ees eestesseeneeseesecseesessecseeseeseseneeeeeneees 12
7. ed Plug the flat ribbon cable with connector onto the pin header of the touchpad panel Screw on touchpad panel with the four screws 485 485 GNDGND Red cable Serial port Solar panel Battery or DC voltage supply Connector clamps 237 drilling dimensions 264 331 458 Serial port connection RS485 The second cable entry point is intended for the serial port connection Remove the key touchpad and take the sealing element out of the cable entry point Pass the cable through the cable entry point and attach it to clamps 1 2 3 and 4 Fix the cable to the cable duct entry Ensure that the cable diameter meets the cable duct entry guidelines otherwise the IP protection rating is not achieved Then screw the key touchpad back on again using the four screws Operating instructions Control elements Key touchpad gt is m a N N a GHI PQRS OKK Q D 3 H Q Q Number key pads Making receiving calls 4 Dialling When receiving a telephone call lift the receiver to answer the call To make a call lift the receiver and dial the number you would like to call Dialling Enter the numb
8. epeated 3 times Sending is terminated after three unsuccessful attempts After receiving the DLE Indutel GSM transmits a data byte Value and meaning of the data byte 81 hex Ringing has started 82 hex Ringing has stopped 83 hex Receiver was lifted pie 84 hex Recover was replaced ETX end of text 03 hex and waits for DLE If a NAK negative acknowledgement or any other signal is sent back as a DLE or there is a timeout sending is repeated 6 times Sending is terminated after 6 unsuccessful attempts Receiving The external apparatus sends STX and waits for LE which is sent by Indutel GSM when it is ready to receive data After receiving the DLE the extemal apparatus sends 1 Data byte value and meaning of the data byte C1 or C2 2 Data byte 8 bit value DLE ETX If transmission has been successful Indutel GSM sends If the data received is not correct or reception was impaired Indutel GSM sends requesting a repeat of the transmission This request will be repeated 6 times After 6 failed attempts sending will be terminated Receiving data should trigger an SMS which states Alarm1 2 2 Data byte General instructions Service You have purchased a modem FHF product which is subject to a thorough quality control inspection If you have any questions about the telephone or if a malfunction appears even after the guarantee period please contact FHF Please have the model name and item number ready See product
9. er you would like to call using the touchpad The star key and the hash key are neutral keys when making a call Once the telephone number has been entered completely press the R key to connect to that number Programming Programming is done via SMS A SIM card must be in the telephone to do this and the telephone must be connected to a network The SMS necessary for programming must be sent to the Indutel GSM from another SMS enabled phone The four 4 digit alphanumeric password currently valid must be included in the SMS text In the following text the password is equal to 0000 Upon successful programming the Indutel GSM will send the following SMS FHFnnnnnn Ok nnnnnn Telephone ID number alpha numeric If programming was unsuccessful the following SMS is retumed FHFnnnnnn ERROR nnnnnn Telephone ID number alpha numeric Setting call volume SMS text FHFO000 FHF VOLRING value value 0 4 Setting call melody SMS text FHFO000 FHF TYPERING value value 0 7 Setting speaker microphone sensitivity SMS text FHFO000 FHF VOLMIC _HS value value 0 9 Setting call reception volume SMS text FHFO000 FHF VOLSPK_HS value value 0 9 SIM cards priority settings The telephone always attempts to dial into the GSM net of SIM card 1 SMS text FHFO000 FHF SIMCHK SIM1 FIX The telephone always attempts to dial into the GSM net of SIM card 2 SMS text FHFO000 FHF SIMCHK SIM2 FIX The telephone first
10. le Receiver capsule Connections Operating environment temp Transport and storage temperature Protection rating as per IEC60529 Cable fitting for cable diameter Quad Band GSM850 GSM 900 GSM1800 GSM1900 5 Vic 10 from solar panel or DC voltage supply 10W recommended open circuit voltage lt 6 9 Vac 500 mA Lithium lon 3 75V approx 5 Ah 20 C to 60 C 50 C to 60 C With fully charged battery Approx 21 hours Approx 30 days With one or two 2 SIM cards With open casing cover Approx 90 dB A at a distance of 1m With closed casing cover Approx 65 dB A at a distance of 1m 330 x 237 x 110 mm 2 3 kg Vertical wall mounted Electret microphone Dynamic capsule Single wire or multi wire up to 2 5 mm 25 C to 55 C 25 C to 70 C IP66 IP65 open casing 2x M16 x 1 5 5 9 mm Conformity declaration FHF Funke Huster Femsig GmbH confirm that the InduTel telephone is in conformance with the fundamental requirements and other relevant provisions of guideline 1999 5 EU R amp TTE However should problems occur during operation please contact the technical support team at FHF CE EMC Electro Magnetic Compatibility Guideline The device meets the requirements of the new EMC guideline 2004 108 EG the Low Voltage guideline 2006 95 EG and the R amp TTE guideline 1999 5 EG Conformity to the guidelines listed above is verified by the C E Conformit Europ enne sign E
11. lectronic devices and old electrical items with this symbol may contain hazardous substances For this reason they may not be disposed of together with regular domestic waste To protect the environment public collection stations are available for the disposal of electronic devices and old electrical items with this symbol Subject to alterations or errors 5 FUNKE HUSTER FERNSI FHF Funke Huster Fernsig GmbH Gewerbeallee 15 19 D 45478 M lheim an der Ruhr Phone 49 208 82 68 0 Fax 49 208 82 68 286 htto Awww fhf de e mail info fhf de

Download Pdf Manuals

image

Related Search

Related Contents

Attenzione - Viessmann  Owner`s Manual  Per scaricare i file di questa sezione in formato PDF cliccare qui  SG2650 board  J. Bouhassira  Frigidaire FGGF305MKF User's Manual  ASUS G750JM User's Manual  Genius Manual  Fiche Programme_ETSL_Ateliers36.indd  to the SwissSTIM® FITNESS user manual.  

Copyright © All rights reserved.
Failed to retrieve file