DVP-EH Function card instruction sheet
Contents
1. it will have error message and can t read data Note Lock state means password in memory card is locked Data transmitted between WPL working area memory card commentary Function selection e WPL working area gt memory card a You can select devices to save in memory card Default is all devices After you select all device you select with commentary will save in memory card b For device M and D special D D1000 D1999 and special M M1000 M1999 won t be wrote into memory card c The commentary capacity in memory card is 32KB It can save 16000 Chinese words or 32000 letters e Memory card gt WPL working area To upload commentary in memory card to WPL working area for user to edit or modify Note Lock state means password in memory card is locked Installation and Maintenance Memory card setup x WPL Editor lt gt Memory card transmission Option Hint area WPL Editor gt Memory card Memory card gt WPL Editor Device Selection Vv x VY VM VS MT Vc VoD MP M Cancel Please make sure that PLC is power off and open extension slot cover before installing or removing function card or memory card The installed position of function card and memory card are shown at the right side Please attach terminal TR i label shipped with package on correct terminal to ee Me avoid error wiring Oa Ss n SS 7 Z DEK RES AAN f E Function card install
2. 256FM is a data backup memory card There is a switch on it Follo ration for each item and relative cautions Data transmission between PLC memory card Function selection e PLC gt memory card a If password in PLC is unlocked but password in memory card is locked data will be wrote into memory card and password in memory card will be disable after executing PLC gt memory card Function Selection PLC gt Memory card Memory card gt PLC The content of transmission are Program area 0 15871 Data register D0 D999 D1035 D1036 D1101 D1103 D1200 D1219 b If password in PLC is locked and no matter password in memory card is locked or not data and password in PLC will be wrote into memory card after executing PLC gt memory card e memory card gt PLC PLC must be in STOP mode It will compare password in memory to password in PLC before executing If passwords are not the same it can t read data Note Lock state means password in memory card is locked D2000 D9999 File register 0 4999 Auxiliary relay MO M399 M1035 M1101 M2000 M4095 Step 50 51023 Counter CO C255 Contact _Coil Timer T0 T255 Contact Coil Password If PLC Pwd Function is enabled Cancel Data is transmitted between WPL working area memory card program al Function selection gt WPL Editor lt gt Memory card transmission e WPL working area gt
3. executing WPLSoft But other a It must o with RS 232 card when connecting MODEM on PLC side If not above special M communication function is normal COM1 is out of this limit are invalid b You must set M1185 On to initial MODEM after MODEM start up M1184 On If not it can t PC 1 AC drive or Servo start up MODEM auto dial function on PLC side me g 7 ki i J c MODEM will enter auto dial mode after initialization Please pay attention to d MODEM will enter to ready for dial mode on PLC side after remote PC stops connection If user signal of pin2 and pin3 turn MODEM power off now it should need to initial at the next time when turning on MODEM when this e The initial format that used to MODEM on PLC side are ATZ and ATSO 1 communication port is n User can use COM2 to connect RS 422 and HMI or other connected to PC or DVP F422 H peripheral for long distance connection The communication HMI Especial that this PC RS 422 o all p function is the same as COM2 except communication definition is different RA g or 244444 wD Extension card for COM2 communication port Rs 485 card L oo interface Note PLC will set that COM2 is occupied by RS 422 from DVP F232 card _ gt card and built in COM2 RS 485 function will be invalid after msering this card Refer to following for system connection DVP F485S E Wiring example RS 485 o fal b i cei m k on COM3 Tx transmission pLccom2 Delta HMI DOPA se
4. memory card a If you don t input any words in password field password field is blank and PLC will check the state of this switch when PLC is power on If this switch is Off memory card will be invalid And it is invalid to change the switch when PLC is power on All memory data read write action will be valid when switch is On DVP 256FM It will check password during date copy If The flowchart for uploading data to PLC there is password in memory card it will also be when installing on MPU and power is on de WPL Editor gt Memory card Function selection Program area j C Memory card gt WPL Editor Password setup iz Confirm z Cancel password in memory card will be clear after pressing Enter button no matter it has password or not before b If you input new password in password field password in memory card will be protected by this new password e memory card gt WPL working area If there is password for memory card you will be asked to input password when executing this function If you don t input password or input error flowchart at the right side There are several sections for copy data in copied to PLC and PLC will be locked See Ore memon can O memory to PLC as shown in the following Data block Setting range D0 D999 D1035 D1038 D1101 D1102 D1103 D1200 D1201 D1202 D1203 D1204 D1207 D1208 D1209 D1210 D1211 D1212 D1213 D1
5. points Use DVP F2AD You need to connect PLC to PC and HMI and also control AC drive Use DVP F232S or DVP F485S There are many PLCs and need to download program quickly copy PLC Use DVP 256FM When parameters want to set by DIP switch without occupy any input Use DVP F8ID points When built in COM 2 is RS 485 but what you need is RS 232 or RS 422 Use DVP F232 or DVP F422 When remote control PLC is by MODEM Use DVP F232 When there are 3 8 variables needed to modify by requirement very Use DVP F6VR often Following is application for DI DO card and Al AO card m DVP F4IP application Terminal Layout Program Explanation esa The input terminals AXO AX3 M1104 i Cato correspond to devices mT M1104 M1109 n C Adding input points AX0 AX3 M1106 External switches 1 3 and D detector control M10 M11 YO M1107 and TO separately according to DVP F2 T application 000 Terminal Layout Program Explanation DC5 30V extemal load 1 i The output terminals AYO AY1 TD correspond to devices M1112 M1113 M10 Adding output points AYO and AY1 and connect to load 1 and load 2 to be controlled by X10 and M10 DVP F2AD application 0 Terminal Layout Program Explanation detector voltage M1000 CHO AD is variable Current value 7 ev ieee ok is DO and average value is D1 A CH1 AD is variable Current value duenera P is D10 and average value is D11 CH1 ee terminal aul Con
6. 214 D1215 D1216 D1217 D1218 D1219 D2000 D9999 0 4999 ili M0 M999 Off M1035 M1101 Off Data register lock with n wor o password password Default All are NOP instruction KO KO KO K1600 K2000 K500 K999 check if there is password in memory card check PLC password y lock with password correct correct or not gt y incorrect memory card won be active K2000 Therefore 256FM card can be used for data K4095 backup and PLC copy It can write PLC major K1 data block according to left table into memory K100 card according to following two steps Step 1 K199 finish setting program parameters file register K220 parameters or other relative latched parameters K234 by using WPLSoft or HPP02 Step 2 choose communication gt communication for memory K235 card in WPLSoft software You can insert this K255 memory card into other EH MPU to finish PLC K500 copy function quickly After this PLC MPU is K899 power on the data in memory card will upload to K200 PLC relative data area only for DVP EH MPU K999 32 points and more K2000 K9999 KO KO Those data in 256FM card can be read wrote by using WPLSoft or HPPO2 but there is limit for editing or read write data For HPP02 it can only read write the DATA in program area and file register area M2000 M4095 Step point S0 S1023 TO T255 C0 C255 Password 4words O Off KO KO ff lunlock state password
7. AA NELTA wii WI http www delta com tw products plc asp 5011621000 ECEO DVP EH Function Card Instruction Sheet WARNING A Always read this manual thoroughly before using Function Extension Card A This instruction provides electrical specification function specification wiring and basic program design For detail program design and instruction explanation information refer to PLC Application Manual programming A This is an OPEN TYPE When installing you should turn MPU power off and have static electricity protection such as wear antistatic gloves to avoid damage those components on function extension card caused by statics A This instruction is for DVP series function extension card Please find out your order model in the following for correct usage INTRODUCTION Thank you for choosing DELTA s PLC extension card of DVP EP EH Series There are analog input output card Al AO digital input output card DI DO extension card for communication port and memory card Refer to following table for detail Applicable Model Name Outline Function Explanation Model _ MPU built in COM1 RS 232 and COM2 RS 485 O When connecting RS 232 to PC or other peripheral DVP F232 fE such as MODEM by using COM2 you can use this RS 232 card extension card The communication function is the lt game as COM2 except communication interface i e l there are Slave mode and Master mode for you to E Terminal L
8. ation Please put function card into slot vertically and tighten accessory screws into correct position Z Sie amp N E Y Vl E Backup memory card installation change switch to On or Off by requirement and removal When inserting memory card in PLC you can read write data in memory card by using WPL The operations are in the following please confirm that switch on memory card is On before PLC is power on And also confirm that connection is successful to read write data in memory card There are three modes PLC memory memory card Using WPLSoft to select communication gt communication for memory card Communication Option Window Help HE pc lt gt PLC HPPXC Ctrl F1 Eal Program verification Te Password P Ctrl F5 A Run PLC R Ctrl Fe Stop Ctrl F HES Ladder monitor starting L Shift Ctrl F1 You can copy data in memory card to PLC or copy data in PLC to memory card 3 WPL working areas memory card program Oa Qaghi sa It can copy program that edited by WPL to memory card or copy PLC program in memory card to WPL working area WPL working area memory card commentary It can copy commentary in WPL to memory card or read commentary from memory card commentary in memory card can be only loaded in WPL working area It can t be loaded in PLC EH MPU and there is no area for saving commentary in EH MPU Shitt 2tr SFC start moni z F2 Shift Ctrl F3 01 Devi
9. ayout DB 9 choose Note PLC will set that COM2 is occupied by male RS 232 card and built in COM2 RS 232 function will be invalid after inserting this card Refer to following for system connection T RS 485 is invalid PC 93 or RS 232 V High high potential i e logic 1 extension card for communication port DVP F232 or DVP F422 Note ey Please pay attention for pin 2 and pin 3 when connecting this communication port to a a PC or HMI f EEEE HMI WE Application example for connection in Slave mode PC RS 232 Delta HMI PLC COM2 HITECH HMI PLC COM2 serial port PLC COM2 DOPA series O ANN OD WN Oa gt TD ON DN DB 9 DB 9 DB 9 es DB 25 FEMALE FEMALE FEMALE MALE E Application example for connecting in Master mode After inserting DVP F232 card into MPU you can use WPL to monitor or upload or download via MODEM connection First you should connect PC and PLC to MODEM separately at the two end of network and turn MODEM power on to operate by following steps MODEM S DVP EP EH series MPU PC g Easy telecommunication W a Q network WPLSoft is executing STEP 1 Setting M1184 On on PLC side start up MODEM Applicable STEP 2 Setting M1185 On start up PLC s MODEM initialization Model Name Outline Function Explanation Model STEP 3 Check the result of MODEM initialization M1186 On means succeed to initial M1187 On EP EH means tale nua There ar
10. ce monitor D Device force onjo Grange vallette Shlht Potn sy Register editor T C DXB Ctrl R Device state editor M 5 THE PLC memory setup M Shift Ctrl F5 PLC Memory lt gt Memory Card WPL Editor lt gt Memory Card Program area WPL Editor lt gt Memory Card Hint area Pai Communication detectina Q E PLC information 1 CtrltAlt I Installation E Check for finishing installation After PLC is power on connect PLC to WPLSoft at PC side In WPLSoft select view gt working area and then select connected model to connect At this time WPLSoft will detect configuration of PLC MPU system and show the result including categories of function card and state of memory card On or Off in working area Refer to WPLSoft user manual for detail All kinds of function card provided by DVP series solve the problem that happened in PLC application For example Usage timing and application requirement SEEEN CNTEE E function card model name When system specification is modified there are not enough points for Use DVP F4IP or use And you need only 1 4 input points or 1 2 output points DVP F2OT Output point of MPU is relay and you need 1 2 points more with transistor Use DVP 20T type There is space limit for installing and need to deal with analog signal Use DVP F2AD or DVP F2DA You need 1 2 analog output points to control AC drive speed Use DVP F2DA Small control system and need 1 2 analog input
11. e 2 analog output points supported by F2DA card and STEP 4 After initialing successful WPL software can be ready for connection on remote PC side WPL their characteristics are shown in the following connection method setting gt modem connection you need to install modem s driver first gt to DVP F2DA get dial connection dialog box and then fill in dial information as following CE oe Voltage output Current output m If you dial a number to access an outside line what is it Please fill in this Analog signal DC 0 10V DC 4 20mA i wms field when it is necessary Output Outside line fo Dialing Less than 0 5Q Less than 0 50 TEL number e201 al Telephone number if there is any area code or city code you don t need impedance C to put anything for distinction Only key the figure one by one directly 2 5mV 10 4000 BuA 20 4000 cet 1 For example 88633626301 12bit Offline state i Extension number Please fill in the field when it is necessary Peel a D1118 setting 2K5 unit ms 3 Dialing times setting redial times when it is fail to connect marae E Digital value e A After finishing input execute dialing to start connection output load 1K 2MQ input 6m9 cay 10V After dialing connection successfully dial connection dialog box will disappear automatically Now you can monitor remote PLC via WPL If there is remote control signal detected on PLC side M1188 will be On and user can know
12. if PLC is monitored by remote control via this special M Note 00 0 1 Communication baud rate can t be changed during MODEM connection MODEM connection digital input digital input baud rate on PLC side is fixed to 9600bps and can t be modified User can move value to D1116 CHO or D1117 CH1 to get correspondent output voltage by using instruction MOV Characteristic cure 2 The MODEM that connected to PLC must provide Auto Answer AA function Communication baud rate for MODEM at two end should be 9600bps and higher a When two built in COM1 RS 232 and COM2 RS 485 3 EP EH series special M definition for MODEM connection following special M is valid when PLC is DVP F232S Fo are not enough for use you can add one COM by this card RUN STOP RS 232 number is 3 and is called COM3 There are two interfaces M1184 Start up MODEM When M1184 On following actions are valid aaa a naiseraG m TC PE e EEE r M1185 Start up MODEM initialization This flag will be Off after finishing initialization 0 8ms 2ms due to COM3 M1186 Fail to initial MODEM When M1185 On M1186 Off tees M1187 Succeed to initial MODEM When M1185 On M1187 Off stele ee eg l a PC2 ane a tet M1188 Disol if MODEM i ted t On means in connection sdsds monitor tftunctiion SIMU taneousIy Ww en IS Slave mode 4 use eae ap ea Sd or not n means im connesnon and connect to PC1 with executing WPLSoft and COM3 also i l l connects to PC2 with
13. ries ILE oo E DVP F232S or DVP F485S i select one Master device COM1 DVP EH MPU E Terminal Layout RS 232 t Delta HMI DOPA series RS 422 is at tansmission i i COM2 and need to set to MODE 2 Refer to following for setting o e receive i p MOREE RS ee si 4g m receive MODE 2 RS 422 DVP F422 COM2 DB 9 MODE 3 RS 485 Master There are 2 analog input points supported by F2AD card and their characteristics are shown in the following Voltage input Current input Analog signal DC 0 10V DC 0 20mA Namn gt 285mV 10 4000 10uA 20 2000 Sue cas sil Input vo 40K 2500 update time i Pi Voltage input for conversion D1118 setting K5 unit ms 0 20mA 4000 _ Digital er Characteristic output cure This digital DIP switch card provides 8 On Off input signals DIO DI7 to oT M105 read value by using instruction API N 109 SWRD It is general used to be input interface of external data setting and doesn t occupy input point X After system finishes every scan time it will auto to read 8 bits of digital switch and set each state in special auxiliary relay M1104 M1111 User can use this 8 special M to operate in the program Refer to following example M1000 K2M1104 D1120 Setting PLC ID by DIP switch F4IP card provides 4 digital input points with photo coupler isolation between PLC After system finishes scan every time it will read 4 bits of
14. these 4 digital input points automatically and set the states separately in M1104 M1107 User can operate this four special M in the program directly E Terminal layout and Input Spec DVP F2AD fr Pa co om o pe N jm O amp oH om m current input oe 0 10V 20mA Input signal limit voltage ae current input Voltage less than 12VDC Inputting negative voltage Digital value Current value D1056 CHO D1057 CH1 Sande output D1110 CHO D1111 CH1 Current less than 30mA Inputting negative current User can get A D conversion value saved in special D by is banned reading special D that corresponds to current value or average value D1118 setting is every update time of current value of digital value output Model Name DVP F20T Outline Applicable Model Function Explanation There are 2 digital output points that provided by F2OT card Output type is AYO act transistor and user can C7 wo driver output points by using M1112 and M1113 eee Voltage spec Max load Response time Output __ Off On 20us 0 3A 1point 30VDC J9 W 1point OnOff 30us DVP F6VR There are two built in analog knob VRO and VR1 in EP EH MPU You can expand analog input equip to VR2 VR7 by using this VR card Refer to API85 VRRD and API86 VRSC in application manual programming for detail
15. version calculation of CH1 AD Detector current produces an input current CH1 If the value D11 reads is K1234 it means input current is Conversion calculation of CHO AD Detector voltage produces an input voltage CHO If the a a value D1 reads is K1472 it means input voltage is 4000 7 I Digital output 1 234 SEENEN l digital 107 output 7 1472x 3 68V 20mA ar TOV 0 20mA _ IA R 4000 EE 1234x pg 12 34mA m DVP F2DA application Terminal layout Program current output M1000 CHO AC drive 1 AC drive 2 Moy Do ome m gt amp E o vov om Conversion calculation of CH1 DA The voltage is outputted to AVI of AC drive to be speed control If you need voltage 5 23V you should give D1 5 23V x aut 10V Conversion calculation of CHO DA The current is outputted to ACI of AC drive to be speed control If you need current 12 34mA you should give A DO a 4000 i 12 34mAx 2468 20mA 1 0V pong analog output 2092 4000 digital input digital output
Download Pdf Manuals
Related Search
Related Contents
Sony SELP-1650 Marketing Specifications Gobo Projector LED user manual Éditeur : L` Argus de l`assurance ISBN : 978-2-354-74076 Xerox WorkCentre 5645s Lib Lib - Fraunhofer SCAI Office Maintenance Guide 2015 HDR-04FE_User Manual_ENG - Telewizja MANUAL DO UTILIZADOR ProxTalker Benutzerhandbuch Display Chiller - Horeca Megastore Copyright © All rights reserved.