1. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com 3 2 3 8kW Single Phase ATS Switched PDU Highlights 200 240V Outlets 8 C13 amp 2 C19 2 C20 12ft Cord e Single phase 16 20A 200 240V Auto Transfer Switch ATS PDU 1 U Rack Mount e Enables redundant A B power MODEL NUMBER PDUMH20HVATNET option for single corded network devices e Separate primary amp secondary inputs connect to any two compatible power sources e 1U horizontal rackmount 10 outlets 8 C13 switched 2 C19 unswitched e Individually switched outlets network interface and 2 digit visual current meter Applications e Ideal for configurations requiring a simple PDU that displays D ot power consumption in amps escription P e Optional use ATS function Tripp Lite Switched ATS Auto Transfer Switch provides a redundant power option for single corded network makes this system ideal for devices Dual input cords support separate connection to PRIMARY and SECONDARY power sources The adding redundancy to single ATS will normally maintain continuous output to all outlets as derived from the primary input cable If the primary corded devices ower source becomes unstable or fails altogether the ATS will switch over to the secondary power source until i ne e ATS function adds hot swap and the primary input is restored and stable Switched PDU features include individually controllable output maintenance by
2. e 2 digit display reports power consumption in amps e 1U horizontal rackmount form factor e 10 outlets 8 C13 switched 2 C19 unswitched e Two C20 inlets for separate Primary and Secondary inputs two 12 ft 3 7m C20 input cables included e ATS circuits normally maintain output sourced from the primary input cable As primary input power fails the ATS will switch to maintain output sourced 1 4 Tripp Lite 1111 W 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com from the secondary input cable until power on the primary input is restored and stable ATS configurations enable hot swappable UPS protection when used with a single UPS and redundant UPS protection when each cord is connected to a separate UPS system in a two UPS environment the primary input cable must be supported by an online UPS with zero transfer time e Advanced ATS configurations utilizing separate mains circuits backup generators and separate out of phase utility power grid feeds are supported e On board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source e 2 7 millisecond transfer time e Switched outlets and ethernet interface supports individual outlet control on a real time or programmable basis and user specified alarm notification thresholds for all reported site power conditions e DHCP Manual configuratio
3. n support Supports HTTP HTTPS PowerAlert Network Management System SMTP SNMPv1 SNMPv2 SNMPv3 Telnet SSH FTP DHCP BOOTP NTP protocols Outlets are factory programmed for sequential turn on at 250 millisecond intervals when the PDU is first energized e LEDs confirm power availability on both input lines and for each output receptacle e TAA Compliant Version Available Order Tripp Lite PXDXUMH2Z0HVATNTAA Specifications OVERVIEW PDU Type Auto Transfer Switch Switched OUTPUT 3 33kW 208V 3 52kW 220V 3 68kW 230V 3 84kW 240V 3 2kW 200V 20A maximum Agency de rated to Output Capacity Details 16A continuous Customized Load Management 8 individually switched C13 output receptacles Receptacles INPUT Two labelled C20 inlets support Primary and Secondary input connections two 12 ft 3 7m C19 to C20 power Input Connection Type cables included Tripp Lite ERRON 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com PDU Plug Type IEC 320 C20 Input Cord Length ft Input Phase Single Phase USER INTERFACE ALERTS amp CONTROLS Front Panel LCD Display Digital display reports total PDU output current in amps 8 LEDs display power on off status for each C13 output receptacle plus 2 additional LEDs to indicate input power Front Panel LEDs status for primary and secondary inputs Toggle switch near digital display enables the setting of HI for 220 230 or 240V
4. nominal applications or LO for Switches 200 or 208V applications PHYSICAL ENVIRONMENTAL COMMUNICATIONS Yes via pre installled SNMPWEBCARD Provides remote monitoring outlet control and automatic power SNMP Compatibility management configurations CERTIFICATIONS TAA Compliant Option TAA Compliant Version Available Order Tripp Lite PDUMH20HVATNTAA Certifications Tested to UL 60950 USA Canada CE Europe Class A Emissions NOM Mexico ROHS Complaint 3 4 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com WARRANTY Product Warranty Period Worldwide 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 414 Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery amp Lifecycle Information Tripp Lite PDUMH20HVATNET
5. pass function to receptacles and built in network interface Super fast switchover between primary and secondary power sources i z La standard UPS configurations occurs within milliseconds ATS functionality is supported by any two compatible AC power sources regardless of phase angle to support a variety of advanced redundant power networking applications Enables fault tolerant Package Includes hot swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord e Switch Metered PDU with ATS is connected to a separate UPS system In a two UPS environment the primary input cable must be supported Support by a full time sine wave UPS with zero transfer time Tripp Lite SmartOnline series is highly recommended for e Set of 2 C19 to C20 12 ft 3 7m use as the primary UPS in a two UPS application ATS configurations utilizing separate mains circuits backup power cables generators and even separate utility power grid feeds are fully supported On board ATS processor constantly e User manual with warranty evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of information lower quality than the primary source Front input LED s display primary or secondary power availability Features e 200 240V 16 20A Automatic Transfer Switch ATS Switched PDU Agency de rated to 16A continuous e Enables redundant A B power option for single corded network devices

Download Pdf Manuals

image

Related Search

Related Contents

ISTRUZIONI D`USO INSTRUCTIONS MANUAL MODE D`EMPLOI  How to Use - Fysiopartner AS  6214667 GBA HD Plus DE.book  Creating a Compact Filing - Interstate Insurance Product Regulation  0 method of payment.indd - Houston Livestock Show and Rodeo  .OTICE NOVACAT 225 ED NOVACAT 265 ED  Service Manual  Creating a Question - The College of Family Physicians Canada  MW-260 - Brother  Manual tualarmaSINcuotas. es G5 Página 1 - Conecta-Me  