1. Top View a 3 000 lt 0 250 DIA la 2 187 gt l 5 PLACES E IL ir HIE IL R 0 125 WD R 0 250 J3 CANINTERFACE J2 2 PLACES DOWN uP 1 000 i NONI S RSS 1 000 Pel Nc S 9 i NO IS C l NC IS 1 000 e Nc S uo IS 7 250 K5 C SS y a M LOAD SHED a 1 000 STATUS PIN 12 N 7 625 NO gy Uu NI S NO KS K3 C SS 1 000 NCH IS Pg AN NC IS x nol fie 1 000 Sl i BATTERY MIDPOINT k MONITOR 0 625 1234 Dr Vv 0 375 la gt 5998 Y Left Side View Front View Right Side View vores ees 1 All Dimensions are in Inches Unless Otherwise Specified 2 Finish Bright Zinc Lorain Spec M500 53 3 Weight Net 12 7 oz Bottom View Shipping 24 oz Page 102 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited
2. TOP VIEW 4 Mounting Position 1 shown with optional List 72 Ringing Generator See recommended position Mounting MTG MTG MTG Angle POS POS POS MCA DISTRIBUTION Distribution Alarm amp Control Detail 1 2 3 Wiring Entrance Wiring Entrance y lt a Ss 3 440 8 a e e i H 21 380 RIGHT SIDE VIEW 22 250 le 23 000 MOUNTING ANGLE DETAIL FRONT VIEW AII Lists 0 220 ET 0 250 x 0 375 SLOT 0 500 AC Input Accepts 3 4 4 p Conduit Fittings 0 1 000 LEFT SIDE VIEW p 1 000 e 0 500 4 0 220 Page 88 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 Installer s Connections Locations and Dimensions List 1 2 3 4 21 22 23 24 AC Input Alarm Control amp Reference AC INPUT Cover Removed O Come z jo o oll El LL O O FRONT VIEW List 1 2 3 4
3. Recm 90 C Wire Size Fuse Circuit Breaker 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG 2 AWG Amperage Loop Length feet s EA 37 6 9 5g 34 5 93 34 5 148 4 5 236 6 49 376 45 597 6 49 15 24 v 39 45 leaves 99 9 157 9 250 4 sea 20A 29 3 4 46 3 4 5 74 3 4 5 118 3 4 5 188 3 4 5 298 3 4 5 25 2 37 3 4 59 3 4 5 94 3 4 5 150 3 4 5 239 3 4 5 30A a TN 31 3 4 49 3 4 5 78 3 4 5 125 3 4 5 199 3 4 5 35A E z 42 82 67 9 107 859 170 6 9 40A 37 34 pg 5 94 649 149 4 5 45A uc 33 9 9 52 3 4 83 9 4 132 34 50A 29 47 7599 119 60A ao 62 9 99 59 70A 5397 85 75 50 79 80 479 7499 90A E m 66 9 100A 2 zs E u 59 3 4 Recommended Crimp Lug 1 Hole 1 4 bolt 245312200 245312400 245312400 245350400 245350600 245350700 245350800 clearance 2 hole 1 4 bolt 245342300 245342300 245342300 245390200 245346700 245346800 245346900 clearance 2 hole No 10 bolt 245390100 245346600 245346500 clearance Table 2 Recommended Distribution Wire Size and Lug Selection Load and Load Return Notes for Tables 2 Wire sizes are based on recommendations of the American National Standards Institute ANSI approved Nationa
4. 11 List 2 23 Power and Distribution Shelf with Load and Battery Shunts Dual AC Feed 12 List 3 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Load Disconnect Dual AG Feed eerta nn rr rrt hn rn aa natara dara iaa ED a 13 List 4 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Battery Disconnect Dual AC e hse e nnn 14 List 6 23 Power and Distribution Shelf with Battery Shunt Dual AC 15 List 7 23 Power and Distribution Shelf with Battery Shunt Low Voltage Battery Disconnect Dual DONAT c 16 List 11 23 Front Access Power and Distribution Shelf with Load Shunt Dual AC Feed 18 List 12 23 Front Access Power and Distribution Shelf with Load and Battery Shunts Dual AC i Q 19 List 13 23 Front Access Power and Distribution Shelf with Load and Battery Shunts Low Voltage Load Disconnect Dual AC 20 List 14 23 Front Access Power and Distribution Shelf with Load and Battery Shunts Low Voltage Battery Disconnect Dual AC Feed
5. TOP VIEW MTG MTG MTG Angle POS POS POS MCA DISTRIBUTION Distribution Alarm amp Control Detail 1 2 3 Wiring Entrance Wiring Entrance 2 a RIGHT SIDE VIEW i 290090 MOUNTING ANGLE DETAIL FRONT VIEW SR 0 250 0 375 gt lt SLOT AC Input Accepts 3 4 0 500 Conduit Fittings d4 Le2 1 000 LEFT SIDE VIEW 1 000 9 0 500 0 220 Page 92 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Additional Dimensions List 6 7 Power and Distribution Shelves When Equipped With List 46 FRONT VIEW Page 93 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems N
6. nnns nenne rennen nennen nennen nnns 21 List 21 23 Power and Distribution Shelf with Load Shunt Single AC Feed 22 List 22 23 Power and Distribution Shelf with Load and Battery Shunts Single AC Feed 23 List 23 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Load Disconnect Single Feed retinet attin bna dnb na hab nae aan na se E 25 List 24 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Battery Disconnect Single Feed 4 icit etit adriana de ka na da aan au aha Yang a nd 26 List 32 Model LXC300 Meter Control and Alarm Assembly MCA sse 27 List 40 AC Line Cord Kit 120VAC sssssssssssssseeee eene nnn nennen sn EEEa EOT R E sss aiai 27 List 41 AC Line Cord Kit 208 240VAQ ssssssssssseseseeee enne eene enne ann ss nnne 28 List 42 AC Input Molex Connector Option 120 208 240VAC 28 List 43 AC Input Vertical Feed Assembly sssssssssssssseseseeeeeee ener enne ennt en nenne 29 List 46 AC Input Molex Connector Option 120 208 240 29 List 47 AC Line Cord Kit 120VAC sssssssssssesssseeee eene ente
7. 33 List 92 Temperature Concentrator Module ssssssssssseseeeeeneeeneen 33 List 93 Battery Temperature Probe Digital 34 List 94 TXM MCA Interface Cable ssssssssssssssseseeeen nnn 34 List 95 TXM MCA Interface Cable ssssssssessssssseseeeee enne nennen nnne enne nnn nnne rsen tenen nnns nnne 34 ACCESSORY DESCRIPTIO NS 2 riri cs issn te cede aea e ea aeae aea a a ee ae ieena 35 Recommended Wire Sizes and Branch Circuit Protection esee 35 AC Input Wire Sizes Branch Circuit Protection esssesssssesses seen enn nnns 35 Distribution Load Wire Sizes and Lugs Bullet Nose Breakers and TPS TLS Fuseholders 38 Load Distribution Wiring GMT en nnns nnns sn 38 Battery Wire Sizes and Lugs List 1 2 3 4 21 22 23 and 24 Power and Distribution Shelves 40 Battery Wire Sizes and Lugs List 6 and 7 Power and Distribution 41 Battery Wire Sizes and Connectors List 11 12 13 and 14 Power and Distribution Shelves 41 External Alarm Reference and Control Wire 2 42 Distribution DeviC6s
8. BUSSMANN GMT ALARM TYPE FUSES FUSE AMPERE RATING PART NUMBER COLOR 18 100 GMT A 248610301 1 4 248610200 VIOLET 1 2 248610300 RED 3 4 248610500 BROWN 1 1 3 248610700 WHITE 2 248610800 ORANGE 3 248610900 BLUE 5 24861 1000 GREEN 7 1 2 24861 1300 BLACK WHITE 10 248611200 RED WHITE 15 248611500 RED BLUE Safety 248898700 _ use Cover Replacement Dummy Fuse 248872600 These fuses not recommended for use in P N 528608 Ringing Distribution Module Replacement Cables MCA Control Bus Termination Plug Features Table 7 Plug must be installed in unused MCA control bus port J10 One plug is furnished with each Integrated Power Distribution Shelf ordered Ordering Notes 1 Forareplacement plug order P N 524651 RJ 45 MCA Control Bus Termination Plug Features Plug must be installed in unused RJ 45 MCA control bus port J3 One plug is furnished with each Integrated Power Distribution Shelf ordered Ordering Notes 1 Forareplacement plug order P N 524653 Page 46 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589
9. TOP VIEW ACCESS COVER REMOVED DETAIL A 0 75 gt e 0 75 gt 0 75 0 75 gt BAT BAT BN A f 0 625 1 4 20 Captive Nuts 6 Places D Factory supplies lug 0 im mounting hardware GROUND D CD 1 4 20 x 0 5 Threaded Studs 10 Places Factory supplies lug 0 755 mounting hardware Note All dimensions are in inches Page 91 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Overall Dimensions List 6 7 Power and Distribution Shelves NOTES 1 All dimensions are in inches 2 Weight In Pounds Net Shipping Shelf 19 Ib 12 oz 25 Ib 4 oz MCA 21b 14 oz 416 9 oz PCU 510 4 oz 7 Ib 13 oz Ring 3 10 802 516 002 3 Finish Shelf and Module Bodies Bright Zinc Front Panels Textured Cool Gray M500 146 Mounting Position 1 shown with optional List 72 Ringing Generator recommended position
10. 86 PHYSICAL SIZE INFORMATION 7 2 88 Overall Dimensions List 1 2 3 4 21 22 23 24 Power 88 Page 6 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Installer s Connections Locations and Dimensions List 1 2 3 4 21 22 23 24 AC Input Alarm Control amp Reference rode ede ces eaa denso 89 Installer s Connections Locations and Dimensions List 1 2 3 4 21 22 23 24 Distribution 90 Installer s Connections Locations and Dimensions List 1 2 3 4 21 22 23 24 Battery 91 Overall Dimensions List 6 7 Power and Distribution Shelves cesses 92 Additional Dimensions List 6 7 Power and Distribution Shelves When Equipped With List 46 93 Installer s Connections Locations and Dimensions List 6 7 AC Input Alarm Control amp n3 Treo peu 94 Install
11. 0 4 8 12 16 20 24 28 32 36 40 AMPS Model LXP1750 PCU Thermal Power Limit 120Vin Typical 70 Ow 250W 500W 750W 60 LK pf ZT V d SY 50 wm 40 E gt 30 A A 80 C 75 C 70T 65 C 20 10 0 0 2 4 6 8 10 12 14 16 18 AMPS Figure 5 Page 70 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Home G High Voltage Shutdown 1 Internal If PCU output voltage exceeds an adjustable preset value and is delivering more than 10 of its rated current the PCU shuts down After approximately 3 seconds the PCU automatically restarts If PCU output voltage again exceeds the high voltage shutdown value within 5 minutes the PCU shuts down and locks out Manual restart is then required If the PCU does not experience a high voltage condition within the 5 minute time period the restart circuit is reset If two or more PCUs are installed in the Power Shelf or if the Power Shelf is paralleled
12. Feeds PCUs in Positions 1 amp 3 Feeds PCU in List 21 22 23 24 Feeds PCUs in Positions 1 2 amp 3 Not Used Position 2 FRAME GROUND No 8 32 x 0 563 Threaded Stud FRAME GROUND oe 8 32 x 0 563 Threaded Stud ALARM REFERENCE amp CONTROL Located on MCA inside the cabinet Alarm Outputs amp Control Inputs TB2 FEE 00 0 0400 0 0 0 0 0 0 0 O 100009909595959 CCo GSC COCOS eco o t n EHE E n On in pn d He D ot a Battery CUTAWAY VIEW Temperature J8 CABINET RIGHT SIDE Probe Web Interface Note All dimensions are in inches Ethernet Page 89 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 Installer s Connections Locations and Dimensions List 1 2 3 4 21 22 23 24 Distribution System Application Guide Spec No 589200300 Model XP4890 Oo ee
13. Connections for AC Input dervied Connections for AC Input dervied from LINE TO NEUTRAL Service from LINE TO LINE Service Bottom View Bottom View Feeds PCU Feeds PCUs in Feeds PCU in Feeds PCUs in Position 2 Positions 1 amp 3 Position 2 Positions 1 amp 3 Rear of Shelf Rear of Shelf Page 95 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Installer s Connections Locations and Dimensions List 6 7 DC Distribution and Battery Front View Load Connections 10 32 Threaded Holes 2 Places per Distribution Position Door Not Shown Factory supplies lug mounting hardware V O o c O E O ar O Load Return Battery Right Side View Battery Connection Return amp C O 10 32 Threaded Holes Ground Connections 2 Places Ground Busbar Factory supplies lug m
14. List 1 23 Power and Distribution Shelf with Load Shunt Dual AC Feed Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Provides 4 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via front access terminal block connections Conduit openings are provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay
15. or LOAD SHED S R DISCON vv vv V FUNCTION MENU cont d ADJUST THE LVD 181 SETPOINTS TURN PCUs OFF OR RESET RESTART 186 or ENERGY MANAGEMENT IS IN CONTROL CHANGE CONFIGURATION 1 GO TO FUNCTION MENU 189 PARAMETERS 2 GO BACK TO MENU TREE FUNCTION TEST MODE BEGINNING 263 or SPECIAL FUNCTION SF IS ACTIVE LAST NODE RECOGNIZED PCU S P or LOAD SHED S R DISCON hh mm or LOAD SHED S Ri NO TIMER RESET RESTART PCU Si P or LOAD SHED S R IN hh mm ss CONFIGURE MENU PROCESSED or CONFIG FILE BEING PANEL S RECONNECT LD BATT vv vv V or LAST NODE RECOGNIZED PROCESSED PANEL Si RECONNECT DSM S clr LD BATT MANUALLY T CONFIG FILE ERROR x LAST NODE RECOGNIZED PROCESSED LOAD SHED S R or NO CONFIG FILE WAS PROCESSED or NO CONFIG FILES ARE PRESENT RCB S P 189A RECON vv vv V or LAST NODE RECOGNIZED RNG S P L R 2 GO BACK TO MENU TREE BEGINNING INI BLE ALI GO TO FUNCTION MENU 2 GOBACK TO MENU TREE BEGINNING N To Sheet 8 From Sheet 8 RELAY ASSIGNMENT MENU ASSIGN RELAY S P Ri FUNCTION RF GO TO CONFIGURE MENU 2 GO BACK TO MENU TREE BEGINNING SPECIAL FUNCTION SELECTION MENU SPECIAL FUNCTION SF DEFINITION GO TO CONFIGURE MENU 2 GO BACK TO MENU TREE BEGINNING SPECIA
16. 2 TEMPERATURE SLOPE Adjustable from 0 0 V C to 0 2 V C D FLOAT SETPOINT Determines Float Mode gt Output Voltage at 25 C Adjustable from 47 0V to 58 0V max MINIMUM COMPENSATION Adjustable from 2 Float to 47 0V D a Maximum setting is automatically limited to 1 0 volt less than HVSD setting v 4 Temperature gt Decreasing Increasing 25 77 F Figure 1 Typical Float Charge Thermal Characteristics Using Optional Battery Temperature Probe 2 1 2 Current Full Load Rated Current Amps No List 53 LXP1000 PCUs List 55 LXP1500 PCUs List 56 LXP1750 PCUs e 120V In 208 240V In 120V In 208 240V In 120V In 208 240V In s 58 0V 46 0V 58 0V 46 0V 58 0V 46 0V 58 0V 46 0V 58 0V 46 0V 58 0V 46 0V Out Out Out Out Out Out Out Out Out Out Out Out 1 8 3 10 87 16 7 21 74 12 5 16 3 25 32 6 125 16 3 30 38 2 16 67 21 74 33 33 43 48 25 32 6 50 65 2 25 32 6 60 76 3 25 0 32 61 50 00 65 22 37 5 48 9 75 97 8 37 5 48 9 90 114 2 1 3 Regulation A Static The associated MCA controls the steady state output voltage to within 0 5 of any voltage setting within the range of 47 0 to 58 0 volts DC for any and all combinations of load from no load to full load input voltage and input frequency at a constant ambient Page 56 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information
17. Mounts in a standard 23 relay rack Restrictions None Page 15 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Ordering Notes 8 9 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order two 2 List 40 120VAC or two 2 List 41 208 240 VAC per List 6 Power Shelf If Molex connector AC input is required order one 1 List 42 or 46 per List 6 Power Shelf If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution and battery disconnect positions order circuit breakers as required per Table 5 Note For battery disconnect positions Electrical Trip white handle circuit breakers are not recommended For bullet nose distribution and battery disconnect positions order fuses as required per Table 6 Order one 1 Part No 1172
18. PCU Si P CURRENT TOTAL PCU CURRENT aaaaaA TOTAL BATTERY CURR aaaaaA GO TO MEASUREMENT CHARGE aaaaaA or TOTAL BATTERY CURR DISCH aaaaaA BATTERY RESERVE TIME hhh mm or BATTERY RESERVE TIME hhh mm EST BATTERY HEALTH CLEAR ALARM MENU GO BACK TO MENU TREE BEGINNING BATTERY CURRENT MENU PANEL S CHARGE aaaaaA 91 or DIST PANEL S DISCH aaaaaA 4 GO MEASUREMENT BATTERY COMPENSATED FOR ttt C F or VIEW THE TEMPERATURE MEASUREMENTS VIEW THE MIDPOINT MEASUREMENTS GO TO FUNCTION MENU GO BACK TO MENU TREE BEGINNING Page 79 of 105 gs ttt C F 4 GO TO MEASUREMENT MENU 2 GO BACK TO MENU TREE BEGINNING MIDPOINT MENU MENU 2 GOBACK TO MENU TREE BEGINNING TEMPERATURE MENU TEMPERATURE PROBE MIDPOINT D RS H 97 vv vvV 1 GOTO MEASUREMENT MENU 2 GOBACK TO MENU TREE BEGINNING This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 BEGINNING
19. THE CONTROLLER IS INITIALIZING NO REMOTE SENSE INPUT or NO INTERNAL SENSE INPUT 1 TEMPERATURE ALARM or TEMPERATURE ALARMS 1 MIDPOINT ALARM or MIDPOINT ALARMS NORMAL DISPLAY MENU SHEET 2 ALARM LIMIT vv vv V NOW AT vv vv V ALARM LIMIT wv vv V lt NOW ww V ALARM LIMIT vv vv V NOW AT vv vv V ALARM LIMIT vv vv V NOW AT vv vv V PCU ALARM MENU PCU S P FAILURE GO TO MAIN ALARM MENU GO BACK TO MENU TREE 2 BEGINNING FUSE ALARM MENU PANEL S LOAD BATT 14 IS OPEN GO TO MAIN ALARM MENU 2 GO BACK TO MENU TREE BEGINNIN 4 G AC ALARM MENU PCU 5 AC OFF OR 16 NO AC DATA PCU 5 AC LINE 17 Too Low PCU S P AC LINE 18 TO HIGH TO MAIN ALARM MENU 2 GO BACK TO MENU TREE BEGINNING DISTRIBUTION ALARM MENU DIST PANEL Sit FAILURE GO TO MAIN ALARM MENU 45 GO BACK TO MENU TREE BEGINNING LVD ALARM MENU To Sheet 3 PANEL S LD BATT LVD IS OPEN or LOAD SHED S R LVD IS OPEN 44 or RECONNECT LOAD SHED S R LVD or RECONNECT ALL LVDs GO TO MAIN ALARM MENU al BEGINNING RELAY ALARM MENU GO BACK TO MENU TREE RINGER ALARM DETAIL MENU RINGER S P L R RING CIRCUIT 55 RINGER S P L R CURRENT LIMIT 55A RELAY BOARD S P 47 FAILURE RINGER S P L R PAIRED UNIT MISSING 56 GO TO MAIN ALARM MENU RINGER S P L R PROCESSO
20. A ADJUST THE SYSTEM 100 PCU CURRENT IS aaaaaA or POWER LIMIT CURRENT aaaaaA MAX T 165 or 2 GO BACK TO MENU TREE TEMPERATURE PROBE BEGINNING Sheet 7 HI 1 ttt C F 166 167 TEMPERATURE PROBE LO 2 IS OFF or TEMPERATURE PROBE LO 2 ttt C F or 168 TEMPERATURE PROBE 169 HI 2 IS OFF or TEMPERATURE PROBE HI 2 ttt C F 170 MIDPOINT D RS H A1 ALARM IS OFF or MIDPOINT D RS H 1 wv vvV 171 TEMPERATURE PROBE 172 LO 1 IS OFF or TEMPERATURE PROBE LO 1 ttt C F 173 MIDPOINT D RS H A2 ALARM IS OFF or MIDPOINT D RS H A2 w vV 174 175 176 177 CHARG 178 179 2 GO BACK MENU TREE BEGINNING 180 2 GO BACK TO MENU TREE BEGINNING Page 81 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 From SHEET 7 Sheet 6 LVD ADJUSTMENT MENU PANEL S DISCONNECT LD BATT vv vv V PCU ENABLE MENU PCU S P IS NOW ON TURN IT OFF or PCU S P IS NOW OFF TURN IT ON
21. MIDPOINT D RS H HI 1 ALARM x MIDPOINT D RS H FA HIGH 2 ALARM zs o _ MIDPOINT D RS H LO 1 ALARM 1 _ MIDPOINT D RS H LO 2 ALARM mj MIDPOINT D RS H NO SIGNAL From Sheet 7 RELAY FUNCTION SELECTION MENU N RELAY FUNCTION RF GO TO RELAY FUNCTION 193 DEFINITION MENU GO BACK TO MENU TREE 0 1 GO TO CONFIGURE MENU 2 BEGINNING 2 GO BACK TO MENU TREE BEGINNING To Sheet 7 Page 83 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 A Binary Inputs The MCA provides four 4 Binary Inputs for external control of system functions The inputs must be mapped by the user to the Special Functions that they are to control The following Special Functions are available 3 1 9 External Control Circuits 1 Emergency Stop Activation of an associated condition inhibits operation of all PCUs 2 High Voltage Shutdown Activation of an associated condition activates the HVSD circuit 3 Thermal Runaway Activation of an associated conditio
22. ambient SHALL BE 50 amperes A circuit breaker or fuse located in the mounting position adjacent to a 40 ampere or 50 ampere circuit breaker or fuse SHALL BE a maximum of 30 amperes Where two 40 ampere or 50 ampere circuit breakers or fuses are used an empty mounting space SHALL BE provided between them Page 21 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current one 1 battery shunt and Low Voltage Battery Disconnect Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via terminal block connections Conduit openings are provided on side panel in front of mounting angle Provides connections for three 3 battery strings via locking type plugs Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug All in
23. 2 1 cere creto cro heo coe ett nae Rar nemo ka noe AKENE 43 Bullet Nose Type Circuit Breakers cccecccecseeceeeeeceeeeeceaeeeeeaeeceeeecaaeeeeaaeseeeeeeeaeeeseaeeeeaaeseeaeeeseeesaeeseneeseaees 43 TPSALTES Type E E 3 tuni eidcm Ur 44 Plug In Alarm Type Fuse Distribution Assembly Part No 529034 6 GMT Alarm Type Fuse Positions for List 1 2 3 4 Power and Distribution Shelves 45 Alarm Type Fuses uerit d tu Ei dec d EO CD PREDA qa c mpi aS 46 Replacement Cables e 46 MCA Control Bus Termination Plug sese sinensis 46 RJ 45 MCA Control Bus Termination Plug sss enemies nennen inneren 46 Bulk Output Cable for List 72 Ringing 47 GMT Distribution Cable for List 6 and 7 sse enne enne nnne nnne nen enn nnne nnns 47 Extension Cable Part No 514153 47 Load Shed Card Part No 528927 47 Ringing Distribution Module Part No 528606 cessent nnne nennen nnns 48 AP6C57EA EB Ring amp Distribution Module 48 Field Replaceable
24. Protection Capacit Sars 1 pacity Wire Size EM EM KM Table 1A Recommended AC Input Branch Circuit Protection and Wire Size Selection 120 VAC Input Two AC Input Circuits Page 35 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 1 2 3 4 6 7 11 12 13 14 208 240 VAC Input Two AC Input Circuits Recm Line Terminals Ground 9 9 Ambient Branch Operating Circuit Recm Recm 90 C 90 Wire Size Wire Size Temperature Protection 1 Amperes Table 1B Recommended AC Input Branch Circuit Protection and Wire Size Selection 208 240 VAC Input Two AC Input Circuits List 21 22 23 24 120 240 VAC Input One AC Input Circuit Recm Line Terminals Ground Ambient Branch Operating Circuit Temperature Protection Capacity Type Recm Recm 90 C Recm 90 C 0 Amperes Torque Wire Size Wire Size 20 to 6 AWG 50 30 Table 1 Recommended AC Input Branch Circuit Protection and Wire Size Selection List 21 22 23 24 208 VAC One AC Input Circuit Page 36 of 1
25. Shunt DC 175A 25 mV Busbar link Busbar link Assembly cable distribution 2U ISD Contactor 1C SPDT 150 Amp 48VDC Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar w o LVD 2U ISD Assembly cable distribution 2U ISD Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar link 2U ISD Assembly cable distribution 2U ISD Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar link 2U ISD Assembly cable distribution 2U ISD Contactor 1C SPST 150A 45V Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar link 2U ISD Assembly cable distribution 2U ISD Contactor 1C SPST 150A 45V 493800264 524769 Cord AC input NEMA L5 30P 8AWG 14 5 ft 524770 Cord AC input NEMA L6 30P 8AWG 14 5 ft Jumpers AC 3 positions Molex Cable clamp 525102 Kit AC vertical feed input assembly Bushing snap 1 3 32 Jumpers AC 3 positions Molex Cover flat connector plate Cover C shape AC input Bracket U flange connector Cord AC input NEMA 5 15 10AWG 10 ft Cord AC input NEMA 5 15 10AWG 6 ft Blank module 534843 Cord AC input NEMA 6 20 10AWG 6 ft 2 Page 52 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America I
26. System Application Guide Spec No 589200300 Model XP4890 Home Parameter Max Min Battery Charge Current Alarm Amps 30000 0 150 Battery eC 57 00 45 00 48 00 Equalize Mode Output Volts 58 00 47 00 56 50 Equalize Time hh mm ss 99 59 00 00 1 00 01 00 00 Auto Equalize Multiplier 15 0 0 Temp Comp Slope mV C 200 Ci Temp Comp Max Volts 58 00 47 00 56 40 Temp Comp Min Volts 58 00 47 00 52 00 Battery Test End Setpoint Volts 57 00 45 00 46 00 Battery Test Sample Interval Seconds 3600 1 60 Battery Test Duration hh mm ss 99 59 00 00 1 00 01 00 00 Battery End Of Reserve Setpoint Volts 51 60 39 60 42 00 Battery Health Setpoint 99 0 75 Battery Reserve Low Setpoint Minutes 600 0 60 Expected Battery Reserve Setpoint hh mm 99 59 00 00 8 00 No Alarm on Recharge Setpoint Hours 24 1 12 Battery High Temp 1 Alarm C 100 50 100 Battery High Temp 2 Alarm C 100 50 100 Battery Low Temp 1 Alarm C 100 50 50 Battery Low Temp 2 Alarm C 100 50 50 Battery Halfstring A1 Setpoint Volts 5 000 0 5 000 Battery Halfstring A2 Setpoint Volts 5 000 0 5 000 Halfstring Alarm Delay Setpoint Seconds 240 0 120 LVD Disconnect Volts 50 00 37 00 42 00 LVD Reconnect Volts 56 00 44 00 49 00 Table 5 MCA Battery Related Settings Remote On Off TR The operation of any or all PCUs can be inhibited
27. o M ESN 5 D 5 o FA E ONS SWS oS e Load Connections 1 4 20 Threaded Hole 1 Place per Distribution Position View with Door Open Factory supplies lug mounting hardware Load Return Connections Note All dimensions are in inches Lug Alignment Pin a ORES Ne 1 Place per Distribution Position Page 90 of 105 GMT Distribution Fuse Load and Load Return Connections TB1 on back of door 1 4 20 x 1 2 Threaded Stud 1 Place per Distribution Position Factory supplies lug mounting hardware This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Installer s Connections Locations and Dimensions List 1 2 3 4 21 22 23 24 Battery See Detail A e GmSmsee BB e 99 o T o opo i 0 o o e e
28. 3 PCUs List 55 1500 Watt Power Conversion Unit PCU List of Parts Features Consists of one 1 Model LXP1500 PCU Spec No 486534204 Page 30 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Ordering Notes 1 Shelf accepts up to three 3 PCUs List 56 1750 Watt Power Conversion Unit PCU List of Parts Features Consists of one 1 Model LXP1750 PCU Spec No 486534600 Ordering Notes 1 Shelf accepts up to three 3 PCUs List 72 Model LXR050 Redundant Ringing Generator Module I ist of Parts Features Provides 1 Model LXRO050 Spec No 487112200 Redundant Ringing Generator Module Module accepts 2 50 VA Ringing Generators Ringing Generators are included Operates from the Power Shelf 48VDC output bus to provide a redundant single frequency ringing system with transfer capability Provides up to 50 VA of continuous ringing power Uses no rack space Mounts in one PCU mounting position in the Power Shelf Either ringing generator in the module can be selected to s
29. 3 and 4 each provide connections for one AC input branch circuit Customer to provide AC input branch circuit protection A Low AC Input Voltage Protection 1 120V Operation If AC input voltage decreases below approximately 90 volts non adjustable each PCU s power conversion circuitry inhibits disabling system output When AC input voltage increases to approximately 90 volts non adjustable the PCU automatically restarts 2 208 240V Operation If AC input voltage decreases to within the range of approximately 90 175 volts non adjustable the PCUs continue to operate but at a reduced maximum output 500W for LXP1000 750W for LXP1500 and LXP1750 When AC input voltage increases to approximately 176 volts non adjustable the PCU automatically switches to full output power If AC input voltage decreases below approximately 90 volts non adjustable the PCU s power conversion circuitry inhibits disabling system output When AC input voltage increases to within the range of approximately 90 176 volts non adjustable the system automatically restarts and operates in the reduced power mode B High AC Input Voltage Inhibit If AC input voltage increases to a preset non adjustable value the PCU s power conversion circuitry inhibits disabling system output When AC input voltage decreases to another preset non adjustable value the system automatically restarts Designed to inhibit at approximately 285 volts AC a
30. 3 to 100A TPS TLS Type Fuse or 1 to 100A Bullet Nose Type Circuit Breaker Caution A circuit breaker with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device A fuse with a rating greater than 70 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker used in ambient temperatures above 50 C ambient SHALL BE 75 amperes The maximum size fuse used in ambient temperatures above 50 ambient SHALL BE 70 amperes Provides 5 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Caution The maximum size fuse used in ambient temperatures above 50 C ambient SHALL BE 10 amperes Provides five 5 GMT Fuse Distribution Cables one per fuse position Each cable is 12 long 16 AWG terminated on one end with a mating connector that plugs into the shelf GMT fuse connector and left un terminated at the remaining end for connection to customer loads Provides 1 battery shunt Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via front access terminal block connections Conduit openings are provided on side panel in front of mounting angle Included are two control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug
31. 50 LIST OF PARTS E EO AEEA H 51 SPECIFICATIONS EE 54 Ve SY SUG A ah chads E 54 1 1 Environmental Ratings ER ea o Pee Rad 54 1 2 Compliance Information sse 54 1 3 Local Controls and 55 25 T A O 55 2 1 OuTpUDRAUNGS 4 2 peret ee federe sue fuv teda dedu 55 PAR s 57 2 3 Standard Feall ES esasi dac a RE ARR TR DAR XXE LER SR cuban das UA TR c REC 64 CI C D E o 73 Bil Standard Eeatures de enda d ek RI RR NX VY UR YR SCR 73 Bi2 Web Interface ei REX XE ER 84 4 List 72 Redundant Ringing Generator System 85 471 Output Ballngsssti teet ce erc a a a 85 42 Input sth he EE 85 4 3 Environmental Ratings 2 c ditus E 85 4 4 Standard D RR SEXE ARR ERR TR REX GNE EKRA
32. Branch Circuit Protection and Lugs TXM Extension Cable Load Shed Card Ringing Distribution Module AP6C57EA EB Ring amp Distribution Module This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 TABLE OF CONTENTS Ordering Information Physical Picture Specifications Size Deed Overview n ey nn List Accessory Parts Documentation Descriptions Descriptions 6 LXP INTRODUCTION etr 1 MODEL XP4890 OVERVIEW simni uoce reinen dana tcc ca aaa aaa poe RE an aaa 1 BBO PdO LONC E EEEE SEEE EES EEE EEE 8 4 TABLE OF CONTENTS a aaa aa aa aeaaea aaa aaa aaa eaaa aaa aaa aaa aa 5 ORDERING INFORMATION ina aaaeaii aaa aa 8 BI Kopp Eo Se Ev SE A a A 8 Deed liae ge 10 LIST DESCRIPTIONS M 11 List 1 23 Power and Distribution Shelf with Load Shunt Dual AC
33. C to 65 C 4 F to 149 D Reduced Load 65 C to 80 149 to 176 1 1 2 Storage Ambient Temperature Range 40 C to 85 C 40 F to 4185 F 1 1 3 Humidity This system is capable of operating in an ambient relative humidity range of 0 to 9595 non condensing 1 1 4 Altitude The maximum operating ambient temperature should be derated by 10 C at an elevation of 10 000 feet above sea level For elevations between 3 000 feet and 10 000 feet derate the maximum operating ambient temperature linearly 1 1 5 Heat Dissipation See input data tables under Paragraph 2 2 Input Ratings 1 1 6 Ventilation Requirements The PCUs and optional Ringing Generators are fan cooled and utilize front to back forced ventilation Each Power Shelf must be mounted so ventilating openings are not blocked and temperature of the air entering the PCUs does not exceed the Operating Ambient Temperature Range stated above In addition the distance from the rear of each Power Shelf to a wall or other solid structure must not be less than one inch This will assure proper airflow through the PCUs See also Paragraph 1 1 12 Mounting 1 1 7 Audible Noise The audible noise at any point one meter from any vertical surface of the Power Shelf with one PCU installed and fan operating does not exceed 55 dBA typical when ambient temperature is below 32 89 6 F and 65 dBA typical when ambient temperature is above 32 89 6 F A Soun
34. Features Provides 1 14 5 ft long AC input cord equipped with a NEMA L5 30P 30A twist lock plug Cordis factory installed Restrictions For 120 VAC only See List 41 for 208 240 VAC applications Page 27 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Not available with List 43 AC Input Vertical Feed Assembly Not available on List 6 or 7 if equipped with List 42 or 46 Ordering Notes 1 For 120VAC operation in List 21 22 23 or 24 shelves order one 1 List 40 per Power Shelf 2 For 120VAC operation in all other List number shelves order two 2 List 40 per Power Shelf List 41 AC Line Cord Kit 208 240VAC Features Provides one 1 14 5 ft long AC input cord equipped with a NEMA L6 30P 30A twist lock plug E Cordis factory installed E Restrictions NEMA 6L 30P For 208 240 VAC only See List 40 for 120 VAC applications Not available with List 43 AC Input Vertical Feed Assembly Not available on List 6 or 7 if equipped with List 42 or 46 Ordering N
35. SHEET 5 PCU INVENTORY DETAIL MENU PCU S _P ASSEMBLY INVENTOHY MENU PCU INVENTORY MENU JBHHHHHHHHHHE SIRING PCU S P IS RATED PCU S _P SERIAL From Sheet 4 K gt or 101 JHHHBHHHHHBHE PCUs ARE PCU S _P BOOTCODE 100 REPORTING 1 GOTO INVENTORY MENU HEHHHEHRHHHHHE To Sheet 4 D NO PCUs ABE 2 GOBACK TO MENU TREE PCU S _P SOFTWARE THHHHHHHHHHHE REPORTING 1 PCU POSITION IS EMPTY or 108 PCU POSITIONS ARE EMPTY or NO PCU POSITIONS ARE EMPTY DISTRIBUTION INVENTORY MENU PANEL S INCLUDES 1 POSITION or PANEL S INCLUDES POSITIONS GO TO INVENTORY MENU 1 DIST PANEL IS REPORTING or DIST PANELS ARE REPORTING or NO DIST PANELS ARE REPORTING 1 RELAY BOARD IS REPORTING or RELAY BOARDS ARE 117 REPORTING or NO RELAY BOARDS ARE REPORTING 1 RINGER IS REPORTING or 124 RINGERS ARE REPORTING or NO RINGERS ARE REPORTING go CONTROLLER ASSEMBLY 130 SENSE VOLTAGE IS REMOTE INPUT 136 or SENSE VOLTAGE IS INTERNAL 109 1 TEMP PROBE IS REPORTING or TEMP PROBES ARE REPORTING or NO TEMP PROBES ARE REPORTING 1 MIDPOINT IS REPORTING or MIDPOINTS ARE 139 REPORTING 137 or NO MIDPOINTS ARE REPORTING 141 UPDATE THE INVENTORY 1 GO TO FUNCTION MENU 2 GO BACK TO MENU TREE BEGINNING 2 GOBACK TO MENU TREE BEGINNING RELAY INVENTORY MENU RELAY BOARD 5 IS REP
36. See recommended position Mounting MTG MTG MTG Angle POS POS POS MCA DISTRIBUTION Distribution Alarm amp Detail 1 2 3 Control Wiring Entrance Battery Wiring Entrance 22 250 RIGHT SIDE VIEW he 23 000 FRONT VIEW MOUNTING ANGLE DETAIL 0 220 E 0 250 x 0 375 AC Input SLOT Accepts 3 4 Conduit Fittings 0 500 0 e LEFT SIDE VIEW 1 000 Page 97 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Installer s Connections Locations and Dimensions List 11 12 13 14 AC Input Alarm Control amp Reference AC INPUT Cover Removed E Sji SSI r3 oo o ooo a SS FRONT VIEW Feeds PCUs in Positions 1 amp 3 ALARM REFERENCE amp CONTROL Located on MCA inside the cabinet Alarm Outputs amp Control Inputs H Feeds PCU in TB2 TBI Position 2 Lok
37. default current limit setting in the Current Limit mode is the sum of each installed PCU s output rating One adjustment changes the setting of all PCUs B Output Fusing Output fusing is provided in each PCU If a fuse opens local and remote PCU Fail Alarms activate This fusing is not customer replaceable C Thermal Power Limiting Each PCU continuously monitors the ambient temperature surrounding the power conversion unit circuit If this temperature for any reason such as a high ambient office temperature increases above approximately 65 C 149 F the PCU will not shut down Rather the PCU will limit its maximum output power to maintain the temperature of the power conversion circuit within design parameters Full power capability is restored when the temperature decreases to below approximately 65 149 F Figure 2 illustrates typical operating parameters Warning The PCU is rated for continuous operation at full output power up to 65 C 149 F Operation between 65 C and 80 C 149 and 176 F is considered abnormal and should be used on a temporary basis only 1 Temporary Operation at Abnormal Temperature Temporary operation refers to a period of not more than eight consecutive hours per day and a total of not more than 15 days in a year This refers to a total of 120 hours in any given year but no more than 15 occurrences in that one year period Page 66 of 105 This document is property of Emer
38. 1 PCU Home per cord recommended branch circuit protection is 15 amperes 6 When List 6 or 7 is equipped with List 42 or 46 refer to Tables 1A 120VAC and 1B 208 240VAC for recommended wire sizes and branch circuit protection Refer to Table 1E for mating connector information 7 Contacts should be crimped to the specifications given in the manufacturer s instructions furnished with the crimp tool or connector Distribution Load Wire Sizes and Lugs Bullet Nose Breakers and TPS TLS Fuseholders Features The installer connects lug terminated load and return conductors to the distribution device mounting positions and the ground busbar Refer to the following table for the lug mounting provisions of the available shelves Each Return Connection Shelf List No Each Load Connection Ground Busbar 1 2 3 4 1 1 4 20 x 1 2 threaded stud amp 21 22 23 24 1 1 5 00 threaded hole 1 alignment pin 5 8 centers 1 10 32 x 1 2 threaded stud amp 6 7 2 10 32 threaded holes 5 8 centers 1 alignment pin 5 8 centers 11 12 13 14 1 1 4 20 threaded hole 1 1 4 20 x 1 2 threaded stud Maximum size of wire to be connected to a single fuseholder or circuit breaker position is 2 AWG For lug mounting hole size and spacing dimensions refer to the illustrations provided in the Physical Size Information section Restrictions All lugs for customer connections must be ordered separately
39. 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts single AC feed 2U 58920030023 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts amp LVLD single AC feed 2U Page 8 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 List Mounting No Part Number Description Positions 1U 1 3 4 Integrated Power amp Distribution Shelf 23 up to 114 Amps 24 58920030024 5250W of power conversion equipped with Load amp Battery 2U Shunts amp LVBD single AC feed 32 58920030032 LXC300 Meter Control Alarm Assembly MCA with Ethernet AC Line Cord Kit 1 14 5 ft cord 120VAC NEMA L5 30P 40 58920030040 Plugs for List 1 2 3 4 21 22 23 and 24 58920030041 AC Line Cord Kit 1 14 5 ft cord 208 240VAC NEMA L6 30P Plugs for List 1 2 3 4 21 22 23 and 24 42 58920030042 AC Input Option Molex connectors on harness for List 6 amp 7 43 58920030
40. 120V nominal input PCUs operate in the Reduced Power Mode In the Reduced Power Mode PCUS provide 1 2 the output current and power available in Full Power Mode Number Nominal Percent Input Heat of PCUs Input of Full Current Dissipation Installed Voltage Load Amperes BTU Hr 25 50 100 0 991 85 1 110 0 993 85 9 120 0 994 86 4 128 0 994 86 5 o o 1 o 237 o o s ove m Maximum Input Current At 100 of full load with output adjusted to 58 volts DC as measured at the output bus List 53 Model LXP1000 PCUs 50 Hz Input 25 C Ambient Nominal Input Number of Input Current Input Voltage Voltage PCUs Installed Amperes oe ye 208 240 87 71 Page 58 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 2 2 5 Typical Input Data List 53 Model LXP1000 PCU 60 Hz input 25 ambient A Output initially adjusted to 54 48 volts DC as measured at the shelf output terminals at 50 of full load and nominal input Percent of Full Load ref
41. 2009 Spec No 589200300 Model XP4890 SHEET 3 PCU ALARM DETAIL MENU From Sheet 2 PCU S P EMERGENCY 21 SHUTDOWN Sheet 2 22 VOLTAGE 23 PCU Si Pi AC OFF OR NO AC DATA 24 PCUSI P AC LINE TOO LOW DISTRIBUTION ALARM DETAIL MENU 25 PCU 5 AC LINE From Sheet 2 C PANEL S LD BATT P TOO HIGH 36 ANOT ROUND og PCU S P POWER PANEL S LD BATT P FACTOR FAIL 37 Monee 0 CURRENT PCU S P DC DC PANEL S CONVERTER 39 LvD FAILURE gg PCU S P OUTPUT IS PANEL S INHIBITED RELAY ALARM DETAIL MENU Een Cue OMBRE From Sheet 2 SRN PANEL S 48 IS STUCK PROCESSOR PCU S P LOAD SHARE RELAY BOARD S PANEL SN CARDA To Sheet 2 49 IS DUPLICATED PCU SPF SLOW EENS PANEL S OR STOPPED so NO RESPONSE 2 POUSEPE RELAY BOARD GO TO DISTRIBUTION IS DUPLICATED 5 is Soni Genie ALARM MENU 33 PCU S P REN OND SE 2 GO BACK TO MENU TREE NO RESPONSE BEGINNING 52 NO RESPONSE E e 2 GO BACK MENU TREE BEGINNING GO TO RELAY ALARM MENU 2 GO BACK TO MENU TREE BEGINNING TEMPERATURE ALARM MENU From Sheet 2 G TEMPERATURE PROBE ALARM LIMIT tttC F 64 HI 1 ALARM 6 8 NOW AT ttt C F To Sheet 2 TEMPERATURE PROBE ALARM LIMIT ttt C F 65 2 ALARM 8 NOW AT ttt C F 66 TEMPERATURE PROBE gt ALARM LIMIT
42. 3 to 100 ampere Bussmann TPS type or Littelfuse TLS type fuse This fuseholder plugs into a single mounting position This fuseholder also provides a GMT A alarm type fuse which operates open to provide an alarm indication if the distribution fuse opens Ordering Notes 1 Order fuses per Table 6 Note Load should not exceed 80 of device rating Caution All Shelves A fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution List 1 2 3 4 21 22 23 24 only The maximum size fuse used in ambient temperatures above 50 C ambient shall be 40 amperes Caution List 6 7 only The maximum size fuse used in ambient temperatures above 50 C ambient SHALL BE 50 amperes for distribution and 70 amperes for battery disconnect Caution List 11 12 13 14 only The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 50 amperes A circuit breaker or fuse located in the mounting position adjacent to a 40 or 50 ampere circuit breaker or fuse SHALL BE a maximum of 30 amperes Where two 40 or 50 ampere circuit breakers or fuses are used an empty mounting space SHALL BE provided between them 2 Order one 1 Part No 117201 TPS TLS type fuseholder for each fuse 3 For lug and wire size selection refer to Table 4 TPS TLS TYPE FUSES jer Part Number Part Number 3 248230900 40 24
43. 8 7 OSCR SOSOy 000959699 02559 90859990099 m Eb FRAME GROUND D ZT 4 pur puru No 8 32 x 0 563 Threaded Stud CUTAWAY VIEW CABINET RIGHT SIDE Battery Temperature Probe J8 Web Interface Ethernet Note All dimensions are in inches Page 98 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Installer s Connections Locations and Dimensions List 11 12 13 14 Distribution and Battery 00 0 00 A Load Connections 1 4 20 Threaded Hole 1 Place per Distribution Position View with Door Open Factory supplies lug mounting hardware to J lo OHHO o IL eis Load Return amp Ground Connections Battery Ground Busbar GMT Distribution Fuse Connectors Load and Load Return Connections a TB1 o
44. 86 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 4 4 8 Over temperature Protection If internal Ringing Generator component temperatures increase above preset value the Ringing Generator will inhibit When the temperature decreases to a safe level the Ring Generator will automatically resume operation 4 4 4 Load Transfer Function A Automatic If the output voltage of the active Ringing Generator decreases below approximately 65 VAC RMS non adjustable for any reason except an overload condition the load will immediately transfer to the standby Ringing Generator B Manual The load can be transferred from one Ringing Generator to the other by means of local controls or from a remote location via the system MCA Web Interface 4 4 5 Indicators A STATUS indicator is provided on each of the two Ringing Generators in the Ringing Generator Module This three color LED illuminates as follows A Green Output available this generator selected to supply load B Amber Output available this generator in standby
45. North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 The equalize time period can be set for 0 to 15 times the discharge time Home period up to a maximum of 300 hours A zero 0 setting disables the feature 2 3 4 Battery Test Output Mode A This mode of operation is used if lower output voltage is required for battery plant testing The Battery Test voltage setting can be checked and or adjusted without removing a PCU or affecting the load One adjustment changes the output of all PCUs B There are two methods of placing the system in the Battery Test mode 1 Method 1 Manual Battery Test A user manually places the system into the Battery Test mode via the MCA interface A user must manually return the system to the Float mode via the MCA interface 2 Method 2 Manually Initiated Timed Battery Test A user manually places the system into the Battery Test mode via the MCA interface The system automatically returns to the Float mode after a preset programmable time period or when the end battery test voltage is reached whichever occurs first 2 3 5 Input Protection Lists 1 2
46. North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 List 93 Battery Temperature Probe Digital Output Features Mounts near the battery to sense battery ambient temperature Plugs into J3 on the MCA Provides MCA with data required for battery temperature related functions temperature compensated output voltage high and low battery temperature alarms 2 1 2 ft long cable Same as List 91 except for cable length See Physical Size Information for probe dimensions Restrictions For use in single probe applications only Cannot be used with a List 92 TXM For multiple probe applications with a TXM order List 90 probes Ordering Notes 1 Order one 1 List 93 or List 91 per system List 94 TXM MCA Interface Cable m w List of Parts Features Cable interface connects between the output connector on the and MCA connector J3 10ft long Can be used in place of the 25 ft interface cable provided with the List 92 when a shorter cable is needed List 95 TXM MCA Interface Cable List of Parts Features Cable interface connects between the output connector on the TXM and MCA connector J3 15 long be used in place of the 25 ft interface cable provided with the List 92 when a shorter cable is needed Page 34 of 105 This document is property of Emerson Netw
47. Password B Page Access Levels User configurations provide a Page Access Level which can be used to limit the functions available to a particular user Eight Page Access Levels are available 4 LIST 72 REDUNDANT RINGING GENERATOR SYSTEM 41 Output Ratings 4 1 1 4 1 2 Power 50 VA Frequency A Nominal 20 Hz B Accuracy The initial frequency is 1596 with output variation from no load to full load over the specified temperature and input voltage range C Distortion Total harmonic distortion THD is less than 596 of the fundamental frequency Voltage A Nominal 86 VAC RMS B Regulation 5 from no load to full load within the specified input voltage range 4 2 Input Ratings 4 2 1 4 2 2 4 2 3 Voltage Negative 44 to 58 volts DC positive ground Negative 60 volts DC maximum transient Current A No Load 90 milliamperes at 48V B Full Load 1 28 amperes at 48V Filtering Noise fed back to a 50 ampere hour battery is less than 32 dBrnC Noise with no battery and one PCU as the source does not exceed 50dBrnC at any ambient temperature 43 Environmental Ratings 4 3 1 Operating Ambient Temperature Range A Operational 40 C to 80 C 40 F to 176 F B Start 30 C to 80 C 22 F to 176 F C Specification Compliant Full Output 20 C to 65 C 4 F to 149 F Page 85 of 105 This document is property of Emerson Network Power Energy Systems North America In
48. Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 2 2 7 Typical Input Data List 55 Model LXP1500 PCU 60 Hz input 25 ambient A Output initially adjusted to 54 48 volts DC as measured at the shelf output terminals at 50 of full load and nominal input Percent of Full Load refers to percent of 25 Amperes per PCU with nominal 208 240V input or percent of 12 5 Amperes per PCU with nominal 120V input Note At 120V nominal input PCUs operate in the Reduced Power Mode In the Reduced Power Mode PCUS provide 1 2 the output current and power available in Full Power Mode Number Nominal Percent of PCUs Input of Full Installed Voltage Load Heat Dissipation BTU Hr Input Current Amperes Wax 760 910 907 osos s75 386 o 8 e oms 85 o ose gt amp osse 9 Wax 715 176 1688 ose 539 B Maximum Input Current At 100 of full load with output adjusted to 58 volts DC as measured at the output bus List 55 Model LXP1500 PCUs 60 Hz Input 25 C Ambient Nominal Input Number of Input Current Input Voltage Voltage PCUS Installed Amperes wr c ERE 208 240 Page 61 of 1
49. System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Overall Dimensions Part No 528608 Ringing Distribution Module R 0 125 R 0 250 2 PLACES 0 250 DIA FUSE power C 2 PLACES 000 RINGING DISTRIBUTION MODULE OUTPUT FUSES 2A MAX FUSE i F2 F3 F4 F5 F6 1 000 esp l a 1 000 d REPLACE WITH TYPE AND RATING OF FUSE y A 1 125 RINGING OUTPUTS 123456 58 S7 v Y Left Side 0 375 e gt Front View Right Side View View NOTES 1 All Dimensions are in Inches Unless Otherwise Specified 2 Finish Clear Zinc Lorain Spec M500 53 3 Weight Net 8 oz Shipping 16 oz Bottom View Page 103 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 RELATED DOCUMENTATION Home I
50. Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 A This unit meets the requirements of UL 60950 Standard for Information Home Technology Equipment and is UL Recognized as a power supply for use in Telephone Electronic Data Processing or Information Processing Equipment B This unit meets the requirements of CAN CSA 22 2 No 60950 00 and is tested and Certified by UL c UR as a Component Type Power Supply 1 3 Local Controls and Indicators See specifications for PCU and MCA 2 PCU 2 1 Output Ratings 2 1 4 Voltage Nominal 48 volts DC Positive Ground A Without Battery Charge Temperature Compensation Float voltage is adjustable from 47 00 to 58 00 volts DC Equalize voltage is adjustable from 47 00 to 58 00 volts DC Battery Test voltage is adjustable from 45 00 to 58 00 volts DC Float Equalize and Battery Test voltages are factory set at 54 00 volts unless otherwise specified The output voltage temperature coefficient does not exceed 0 01 per degree centigrade from 40 C to 65 B With Battery Charge Temperature Compensation Probe With an optional battery temperature probe installed the MCA automatically increases or decreases the output voltage as battery temperature decreases or increases respectively Float voltage is factory set at approximately 54 48 volts at 25 C battery temperature The Float E
51. XP4890 Issue AM September 21 2009 E Refer to Figure 4 for a curve that represents the typical LXP1500 output power characteristics at various ambient temperatures Output voltage and current limit are set to maximum Model LXP1500 PCU Thermal Power Limit 208 240Vn Typical VOLTS 0 4 8 12 16 20 24 28 32 36 AMPS Model LXP1500 PCU Thermal Power Limit 120Vin Typical VOLTS Figure 4 Page 69 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 F Refer to Figure 5 for a curve that represents the typical LXP1750 output power characteristics at various ambient temperatures Output voltage and current limit are set to maximum Model LXP1750 PCU Thermal Power Limit 208 240Vin Typical ow 1750W 70 VOLTS
52. amp SAG589200300 S System Application Guide EMERSON Spec No 589200300 Model XP4890 Network Power Issue AM September 21 2009 LXP INTRODUCTION LXP is Emerson Network Power s next generation small power platform MODEL XP4890 OVERVIEW Model XP4890 is a 48VDC Integrated Power System that operates with LXP Power Conversion Units PCUs powered from 120 208 240 VAC and featuring constant power design This single shelf Power System provides up to 5250 watts of power conversion and distribution PCUs The heart of this system is the LXP Power Conversion Unit PCU Available in three output ratings the LXP PCU operates at 0 99 power factor and with less than 5 THD Designed for positive ground applications the PCU normal output voltage ranges from 47 to 58 volts with an equalize voltage adjustable down to 47 volts and a test voltage adjustable down to 45 volts Each PCU monitors the input voltage and automatically selects one of two operating modes Full output is available for nominal 208 240VAC operation A reduced power mode provides half power for nominal 120VAC input For 208 240V applications the reduced power mode means that the PCU does not inhibit at low line but reduces its output to half The system can be set by the user to operate the PCUs in either the Power Limit or Current Limit mode Power Limit Mode With the system set to the Power Limit mode the PCUs will operate as a constant voltage source or
53. required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 10 For GMT alarm type fuse distribution positions order fuses as required per Table 7 Page 13 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 11 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section List 4 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Battery List of Parts Disconnect Dual AC
54. unless load current increases to the user adjustable current limit setpoint maximum is 110 of full load rating e Constant Current Source If load current increases above the current limit setting output voltage decreases linearly to maintain output current at current limit PCUs will continue to operate in higher ambient temperatures at reduced power Refer to Paragraph 2 3 6 C for further information regarding thermal power and current limiting Page 1 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 MCA Home The Model LXC300 MCA controls the steady state output voltage to within 0 596 of any setting from no load to full load The MCA provides a two line vacuum fluorescent display and keypad for local user interface as well as an integrated Web Interface for remote access via an Ethernet connection Distribution Power distribution is provided through up to 4 bullet nose circuit breakers or TPS TLS fuses as well as up to 10 GMT alarm type fuses Battery protection is available through Low Voltage Load Di
55. with other Power Shelves only the PCU causing the high voltage condition shuts down The high voltage shutdown point can be checked and or adjusted without removing a PCU One adjustment changes the setting of all PCUs Adjustable from 48 00 to 59 50 volts DC Factory set at 57 50 volts unless otherwise specified 2 Remote See Paragraph 3 1 9 B 3 Backup If PCU output voltage exceeds a second non adjustable value the PCU shuts down and locks out regardless of load Manual restart is then required 2 3 7 DC DC Converter Failure If a PCU s DC DC converter fails the PCU shuts down After approximately 30 seconds the PCU automatically restarts If a DC DC converter failure condition occurs again within 5 minutes the PCU again shuts down and again restarts in approximately 30 seconds If a failure condition occurs a third time within 5 minutes the PCU shuts down and locks out Manual restart is then required If the PCU does not experience a DC DC converter failure condition within the 5 minute time period the restart circuit is reset 2 3 8 Power Factor Corrector Converter Failure PCU s power factor corrector converter fails the PCU shuts down After approximately 30 seconds the PCU automatically restarts 2 3 9 Paralleling This system may be connected in parallel with any rectifier of the same polarity and adjusted to the same output voltage 2 3 10 Load Sharing The MCA load sharing feature automatically balanc
56. 01 fuseholder per fuse ordered in 7 above 10 Order one 1 Load lug two hole No 10 bolt clearance holes on 5 8 centers and one 1 Load Return lug two hole No 10 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 11 For GMT alarm type fuse distribution positions order fuses as required per Table 7 12 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 4 6 and 7 Power and List 7 Distribution Shelves in the ACCESSORY INFORMATION section 23 Power and Distribution Shelf with Battery Shunt Low Voltage Battery List of Parts Disconnect Dual AC Feed Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and 80A of distribution at ambient temperatures of 50 or less and 60A at ambient temperatures above 50 Provides 3 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size ci
57. 043 AC Input Vertical Feed Assembly 46 58920030046 AC Input Option shelf mounted Molex connectors for List 6 amp 7 AC Line Cord Kit 2 120VAC NEMA 5 15P Plugs 6 and 10 ft length available for List 11 12 13 and 14 only B AC Line Cord Kit 2 240VAC NEMA 6 20P Plugs 6 and 10 ft 48 58920030048 available for List 11 12 13 and 14 only 50 58920030050 Blank Module Model LXP1000 Power Conversion Unit PCU 1000W 48V 53 58920030053 120 208 240VAC Model LXP1500 Power Conversion Unit PCU 1500W 48V 55 58920030055 120208 240VAC Model LXP1750 Power Conversion Unit PCU 1750W 48V 56 58920030056 J oq 208 240VAC 72 58920030072 Redundant Ringing Generator Module 50VA In shelf 78 58920030073 Replacement Ringing Generator for List 73 80 58920030080 Cable Local Computer Access 81 58920030081 Cable RJ 45 MCA Control Bus 58920030090 Battery Temperature Probe Analog 58920030091 Battery Temperature Probe Digital 25 ft cord 58920030092 Temperature Probe Concentrator Module TXM 58920030093 Battery Temperature Probe digital 2 1 2 ft cord 58920030094 Cable interface TXM to MCA 10 ft long 58920030095 Cable interface TXM to MCA 15 ft long C cO cO 11 6 168 1 81 Page 9 of 105 This document is property of Emerson Network Power
58. 05 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 2 2 8 Typical Input Data List 56 Model LXP1750 PCU 50 Hz input 25 ambient A Output initially adjusted to 54 48 volts DC as measured at the shelf output terminals at 5096 of full load and nominal input Percent of Full Load refers to percent of 29 2 Amperes per PCU with nominal 208 240V input or percent of 12 5 Amperes per PCU with nominal 120V input Note At 120V nominal input PCUs operate in the Reduced Power Mode In the Reduced Power Mode PCUS provide less than 1 2 the output current and power available in Full Power Mode Number Nominal Percent Heat of PCUs Input of Full ghe ss t Dissipation Installed Voltage Load BTU Hr ke Tai 25 73 4 210 50 343 412 409 0 991 83 3 233 100 653 780 777 0 997 87 6 328 110 0 997 87 9 354 120 0 997 87 8 375 128 0 997 87 7 378 Ma 759 906 904 oss sre 383 o os 25 129 1957 19 os 908 630 oss 1976 1965 09 900 5
59. 05 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 List 21 22 23 24 208 VAC mEZCI E One AC wmm Recm Line Terminals e Terminals Ground Ambient Branch Operating Circuit Temperature Protection Capacity Type Recm Recm 90 C Recm 90 1 Amperes Torque Wire Size Wire Size 20 to 6 AWG 50 C 35 Table 1D Recommended AC Input Branch Circuit Protection and Wire Size Selection List 21 22 23 24 208 VAC One AC Input Circuit Contact Vendor Housing Wire C it Part N Hand Crimp Tool Seno Molex Part No Molex 0428160312 10 12 AWG 42815 0012 63811 1600 Emerson Network Power 133302 0428160312 8 AWG 42815 0032 63811 1500 Emerson Network Power 133302 133301 Table 1E List 42 and 46 Mating Connectors Notes for Tables 1A 1B 1C 1D and 1E 1 Wire sizes are based on recommendations of the American National Standards Institute ANSI approved National Fire Protection Association s NFPA National Electrical Co
60. 2 10A Alarm SAN O Fuse A7000627 AP8C55AA 50VA Ring Generator Page 49 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Field Replaceable Components Ordering Notes 1 MCA Order via List 32 2 PCU Order via List 53 Model LXP1000 List 55 Model LXP1500 or List 56 Model LXP1750 3 Fan for List 53 LXP1000 PCU Order Part No 534444 4 Fan for List 55 LXP1500 PCU Order Part No 534444 5 Fan for List 56 LXP1750 PCU Order Part No 534444 6 DSM Order Part No 524520 7 Ringing Generator P N 487112100 for List 72 Order via List 73 8 Kit Fan Replacement for Part No 487112100 Ringing Generator Order Part No 534637 Kit includes 1 P N 534365 fan 3 P N 130823 mounting pins 3 P N 534571 washers Page 50 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permi
61. 200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Bulk Output Cable for List 72 Ringing Generator Home Features 6 ft long cable connects to rear of List 72 Ringing Generator Module to provide ringing output connection Also provides DC power connection for a Part No 528608 Ringing Distribution Module Ordering Notes 1 For a replacement cable order Part No 529059 GMT Distribution Cable for List 6 and 7 Features 12ft long cable connects to one GMT distribution fuse connector on a List 6 or List 7 shelf Conductors are 16 AWG terminated on one end with mating connector and left un terminated at the remaining end for connection to customer loads Consists of Molex housing P N 39 01 2025 and terminals P N 44476 3112 loose or 44476 3111 reel Ordering Notes 1 Forone 1 replacement cable order Part No 535206 TXM Extension Cable Part No 514153 Features be used between a List 90 Battery Temperature Probe cable and the List 92 or to extend a Part No 521228 TXM to MCA interface cable 2bft long Load Shed Card Part No 528927 Features Provides eight 8 relays that can be individually configured as additional alarm relays or as Low Voltage Disconnect control relays for reducing the system load load shed If configured for load disconnect control of the relays can be based upon either system voltage or battery discharge elapsed time Provides fo
62. 300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Home List 80 Local Computer Access Cable Features Category 5 Crossover cable terminated at each end with an RJ 45 plug Required for local PC access to the MCA s Web interface Plugs into MCA s Ethernet connector on the Power Shelf Cable identification color is yellow Ordering Notes 1 Order the required length from the following table Length Part Number Length Part Number 36 inches 514642 25 feet 514645 4 feet 514643 50 feet 514646 6 feet 514644 100 feet 514647 15 feet 524726 Features Category 5 Straight Through cable terminated at each end with an RJ 45 plug List 81 RJ 45 MCA Control Bus Cable Required for MCA control bus interconnections e Cable identification color is blue Restrictions Maximum combined MCA control bus cable length must not exceed 125 feet Ordering Notes 1 Order the required length from the following table Length Part Number Length Part Number 5 inches 524409 2 feet 524410 6 inches 509070 3 feet 514639 10 inches 528520 4 feet 509900 15 inches 509071 25 feet 514640 List 90 Battery Temperature Probe Analog Output Features List of Parts Senses battery internal temperature via mounting on negative battery terminal Mounting hole provides clearance for 5 16 bolt Provides MCA w
63. 68 o ws amp osi 230 50 376 o4 os sos 283 15 e22 16 1953 0902 906 627 B Maximum Input Current At 100 of full load with output adjusted to 58 volts DC as measured at the output bus List 56 Model LXP1750 PCUs 50 Hz Input 25 C Ambient Nominal Input Number of Input Current Input Voltage Voltage PCUS Installed Amperes wr c ERE um 208 240 11 2 Page 62 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 2 2 9 Typical Input Data List 56 Model LXP1750 PCU 60 Hz input 25 ambient A Output initially adjusted to 54 48 volts DC as measured at the shelf output terminals at 5096 of full load and nominal input Percent of Full Load refers to percent of 29 2 Amperes per PCU with nominal 208 240V input or percent of 12 5 Amperes per PCU with nominal 120V input Note At 120V nominal input PCUs operate in the Reduced Power Mode In the Reduced Power Mode PCUS provide less than 1 2 the output current and power available in Full Power Mo
64. 750 Watts max 120V 29 2A 58 0VDC to 38 0A 46VDC 1750 Watts max 208 240V 12 5 58 0VDC to 16 3A 46VDC 750 Watts max 120V List 1 2 3 4 21 22 23 24 100 Amperes max List 6 7 80 Amperes 9 50C or less ambient 60 Amperes above 50C ambient List 11 12 13 14 100 Amperes 50C or less ambient 90 Amperes above 50C ambient UL 60950 Recognized CAN CSA 22 2 Equipment Shelf for Relay Rack Mounting 23 12 3 5 5 List 1 2 3 4 21 22 23 24 Front sides top for installation front for operation and maintenance List 6 7 Front sides for installation front for operation and maintenance List 11 12 13 14 Front for installation operation and maintenance None Microprocessor Textured Cool Gray 120V Line Cord Kit 208 240V Line Cord Kit Local Computer Access Cable MCA Control Bus Cable Analog Battery Temperature Probe Digital Battery Temperature Probe Battery Temperature Probe Concentrator Module 50 VA Redundant Ringing Generator Module Circuit Breakers Fuses Lugs Replacement MCA Control Bus Termination Plug Load Shed Card Ringing Distribution Module AP6C57EA EB Ring amp Distribution Module Field Replaceable Components 20 C to 65 C 4 to 149 F 65 C to 80 C 149 F to 176 F Page 3 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary informatio
65. 8233300 5 248231000 50 248233900 6 248231200 60 248234200 10 248231500 70 248234500 15 248231800 80 118413 20 248232100 90 118414 25 248232400 100 118415 30 248232700 TPS TLS Type Fuseholder 117201 Fuseholders are not furnished and must be ordered as required Order 1 Part No 117201 for each fuse position required Fuseholder includes 1 alarm fuse Bussmann GMT A 18 100 amp Emerson Network Power 248610301 and 1 alarm fuse safety cover Emerson Network Power P N 248898700 Unless otherwise specified fuses shall be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Table 6 Page 44 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Plug In Alarm Type Fuse Distribution Assembly Part No 529034 6 GMT Alarm Type Fuse Positions for List 1 2 3 4 Power and Distribution Shelves Features Mounts in 2 bullet nose distribution positions of a List 1 2 3 4 21 22 23 or 24 30A Maximum Capacity Provides 6 Load Distribution Fuse Posi
66. 9 14 1 2 AWG 1 245346900 119 29 2 2 AWG 2 245346900 100 50 59 14 1 2 AWG 1 245346900 119 29 2 2 AWG 2 245346900 65 75 18 2 4 AWG 2 245346800 112 28 3 4 AWG 3 245346800 Table 3A Recommended Battery Wire Size and Lug Selection Notes for Tables 3 1 Wire sizes are based on recommendations of the American National Standards Institute ANSI approved National Fire Protection Association s NFPA National Electrical Code NEC Table 310 16 for wire rated at 90 conductor temperature operating in ambient temperatures of 40 50 and 65 was used For other operating ambient temperatures refer to the NEC For operation in countries where the NEC is not recognized follow applicable codes Page 40 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Recommended wire sizes are sufficient to restrict voltage drop to the voltage shown in the Home column heading or less at rated full load output current of the shelf for the loop lengths shown in this column Loop length is the sum
67. Batory Reserve Alma Bl Ringer Alarms System Measurements n Page 84 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 3 2 1 Description The Web Interface provides remote access to the system monitoring Home 3 2 2 3 2 3 3 2 4 3 2 5 3 2 6 and control functions that are available locally at the MCA control panel See Chapter 5 Using the Web Interface in the System s User Manual for complete descriptions of all Web Interface functions Connection Ethernet RJ 45 10BaseT jack This jack has a standard Ethernet pin configuration scheme twisted pair Use shielded Ethernet cable grounded at both ends The LXP s RJ 45 jack is connected to chassis ground The Ethernet port is suitable for connection to intra building or non exposed wiring or cabling only Web Browser Microsoft Internet Explorer 5 0 or newer is required Screen Resolution 1024 x 768 or greater is required Users 64 maximum Security A Password Protection When logging onto the system the user is prompted to enter a User
68. Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other circuit breaker or fuse Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 50 amperes A circuit breaker or fuse located in the mounting position adjacent to a 40 ampere or 50 ampere circuit breaker or fuse SHALL BE a maximum of 30 amperes Where two 40 ampere or 50 ampere circuit breakers or fuses are used an empty mounting space SHALL BE provided between them Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current and one 1 battery shunt Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via terminal block connections Conduit openings are provided on side panel in front of mounting angle Provides connections for three 3 battery strings via locking type plugs Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug All installer s connections are made through the front See Physical Size Information for dimensions Restri
69. D dual AC feed 2U ID 58920030006 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Battery Protective Device and Battery Shunt dual AC feed 2U IN 58920030007 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Battery Protective Device Battery Shunt amp BLVD dual AC feed 2U 5892003001 1 23 Integrated Power amp Distribution Shelf All Front Access Connections up to 114 Amps 5250W of power conversion equipped with Load Shunt dual AC feed 2U 58920030012 23 Integrated Power amp Distribution Shelf All Front Access Connections up to 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts dual AC feed 2U 58920030013 23 Integrated Power amp Distribution Shelf All Front Access Connections up to 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts amp LVLD dual AC feed 2U 58920030014 23 Integrated Power amp Distribution Shelf All Front Access Connections up to 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts amp LVBD dual AC feed 2U 58920030021 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Load Shunt single AC feed 2U 58920030022 Integrated Power amp Distribution Shelf 23 up to
70. Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Accessory Options Order the following by the items Part Number as specified in the following table When viewing electronically click on the ink to jump to the detailed description page Description Part Number Recommended Wire Sizes Branch Circuit Protection and Lugs Distribution Devices Repl t Cabl See ACCESSORY TXM Extension Cable Part No 514153 DESCRIPTIONS Section Load Shed Card Part No 528927 Ringing Distribution Module Part No 528608 Field Replaceable Components Page 10 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 LIST DESCRIPTIONS
71. Feed Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Provides 4 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current one 1 battery shunt and Low Voltage Battery Disconnect Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via front access terminal block connections Conduit openings are provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Re
72. L FUNCTION DEFINITION MENU rj TEMPERATURE PROBE 251 Hl 1 ALARM 1 TEMPERATURE PROBE 252 HI 2 ALARM 253 Q4 _ BINARY INPUT Bli IS OP CL GO TO SPECIAL FUNCTION MENU 2 GO BACK TO MENU TREE BEGINNING ASSIGN RELAYS TO 247 FUNCTIONS 249 DEFINE SPECIAL FUNCTIONS NETWORK ADDRESS MENU MAC ADDRESS 254 CHANGE NETWORK a 255 ADDRESSES EWAY RINGER S P L R IS RE ACTIVE 261 or RINGER S P L R INACTIVE SET ACTIVE 262 GO TO CONFIGURE MENU 2 GO BACK TO MENU TREE BEGINNING GO TO FUNCTION MENU 1 2 GO BACK TO MENU TREE BEGINNING Page 82 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 SHEET 8 RELAY FUNCTION DEFINITION MENU r TEMPERATURE PROBE HI 1 ALARM TEMPERATURE PROBE HI 42 ALARM 0 _ TEMPERATURE PROBE LO 1 ALARM 0 _ TEMPERATURE PROBE ue RN EIER LO 2 ALARM q TEMPERATURE PROBE NO SIGNAL cj SINGLE RINGER FAILURE x RINGER PAIR FALURE NO RINGERS IN INVENTORY x
73. LAY S R IS A LOAD SHED or SET RELAY S R TO ALARM RELAY or SET RELAY S R TO LOAD SHED BOARD S ASSEMBLY 120 IHHHHHHHHHHHE 121 BOARD S SERIAL THHHHEHHHHHHE 122 BOARD S BOOTCODE THHHHHHHEHHHE 123 BOARD S SOFTWARE THHHHHHHEHHHE 1 GOTO RELAY BOARD INVENTORY 2 GOBACK TO MENU TREE BEGINNING RINGER INVENTORY DETAIL MENU RINGER 5 L R ASSEMBLY 126 IHHHHHHHHHHHE RINGER 5 L R SERIAL THHHHHHHEHHHE RINGER 5 L R BOOTCODE THHHHEHHHHHHE RINGER 5 L R SOFTWARE THHHHHHHEHHHE 127 128 129 1 GOTORINGER INVENTORY 2 GOBACK TO MENU TREE BEGINNING This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 142 VOLTS amp AMPS ADJUST THE ALARM 2 146 148 sETPOINTS L 462 ADJUST THE BATTERY j iid SETPOINTS SHEET 6 SYSTEM ADJUSTMENT MENU Fro m ALARM ADJUSTMENT MENU 133 E Sheet 4 YSTEN LTAGE 144 TR 145 FUNCTION MENU BATTERY ADJUSTMEN T MENU cont d from previous page 1 r
74. LXP1500 PCU 50 Hz input 25 ambient A Output is initially adjusted to 54 48 volts DC as measured at the shelf output terminals at 50 of full load and nominal input Percent of Full Load refers to percent of 25 Amperes per PCU with nominal 208 240V input or percent of 12 5 Amperes per PCU with nominal 120V input Note At 120V nominal input PCUs operate in the Reduced Power Mode In the Reduced Power Mode PCUS provide 1 2 the output current and power available in Full Power Mode Number Nominal Percent Input of PCUs Input of Full Current Installed Voltage Load Amperes Heat Dissipation BTU Hr 259 25 0 967 70 6 241 50 0 987 83 3 233 100 0 995 87 6 329 110 0 995 87 9 352 120 0 996 88 0 371 128 0 996 87 8 377 o o ova 2 12 1700 1685 ossi 909 523 o ove oss 228 Me 7 42 1710 1686 os 906 sa B Maximum Input Current At 100 of full load with output adjusted to 58 volts DC as measured at the output bus List 55 Model LXP1500 PCUs 50 Hz Input 25 C Ambient Nominal Input Number of Input Current Input Voltage Voltage PCUS Installed Amperes Power Efficiency Factor 96 208 240 wr c ERE 965 Page 60 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network
75. NFORMATION section 12 For ringing and DC distribution in imbedded subscriber loop carrier systems such as SLC 96 or SLC Series 5 order one 1 AP6C57EA EB Ring amp Distribution Module See Accessory Information List 21 23 Power and Distribution Shelf List of Part with Load Shunt Single AC Feed S Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Provides 4 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified Page 22 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcur
76. ORTING GO TO INVENTORY MENU 2 GOBACK TO MENU TREE BEGINNING RINGER INVENTORY MENU RINGER S P L R IS REPORTING GO TO INVENTORY MENU 2 GOBACK TO MENU TREE BEGINNING CONTROLLER INVENTORY DETAIL MENU CONTROLLER SERIAL 191 IHEHHHHHHHHHE CONTROLLER BOOTCODE THHHHHHHHHHHE CONTROLLER SOFTWARE THHHHHHHEHHHE CONTROLLER S P IN SHELF 132 133 134 BINARY Bi ALARM ON OPEN INPUT 135 or BINNARY Bit ALARM ON CLOSED INPUT 1 GO TO CONTROLLER MENU GO BACK TO MENU TREE 4 BEGINNING TEMPERATURE INVENTORY MENU TEMPERATURE PROBE IS 138 REPORTING 1 GOTO INVENTORY MENU 2 GO BACK TO MENU TREE BEGINNING MIDPOINT INVENTORY MENU MIDPOINT D RS P H IS REPORTING GO TO INVENTORY MENU GO BACK TO MENU TREE BEGINNING Page 80 of 105 PSC S _P BOOTCODE THHHHHHHHHHHE PSC Sit P SOFTWARE THHHHHHHEHHHE GO TO PCU INVENTORY 2 GO BACK TO MENU TREE BEGINNING DISTRIBUTION INVENTORY DETAIL MENU PANEL S LD BATT P IS INSTALLED 111 PANEL S HAS A LD BATT LVD 112 or PANEL S LD BATT LVD NOT INSTALLED PANEL S ASSEMBLY 113 MHHEHHHHHHHHE PANEL S SERIAL THHHHHHHEHHHE PANEL S BOOTCODE THHHHHHHEHHHE PANEL S SOFTWARE THHHHHHHHHHHE 1 GOTO DISTRIBUTION INVENTORY 2 GOBACK TO MENU TREE BEGINNING 114 115 116 RELAY INVENTORY DETAIL MENU RELAY S R IS AN ALARM RELAY or RE
77. Ohio 44052 2293 440 288 1122 In Canada Emerson Network Power Canada 363 Sovereign Road London Ontario N6M 1 800 265 9243 amp In Mexico EMERSON Emerson Network Power de Mexico S A de C V Network Power Apartado Postal 77001 Mexico 10 D F MX 11200 525 576 8277 Page 105 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited
78. Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If an AC line cord is required order one 1 List 40 120VAC or one 1 List 41 208 240 VAC per List 22 Power Shelf If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above 10 Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 11 For GMT alarm type fuse distribution positions order fuses as required per Table 7 12 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section Page 24 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North Ame
79. Ordering Notes 1 The rating of the distribution device determines the wire size requirements For wire size and lug selection refer to Table 2 2 For other available lugs and hardware refer to drawings 031110100 through 031110300 Load Distribution Wiring GMT Fuses Features List 1 2 3 4 11 12 13 14 21 22 23 24 Screw compression type terminals are provided for connection of Load and Load Return conductors to the GMT alarm type distribution fuse positions Terminals accept 14 AWG max List 6 7 Latching type connectors are provided for connection of Load and Load Return conductors to the GMT alarm type distribution fuse positions Mating cables 12 ft long 16 AWG are furnished Restrictions None Ordering Notes 1 The rating of the distribution device determines the wire size requirements For wire size refer to Table 2 List 6 7 only Order 1 Part No 535206 load cable for each GMT fuse distribution position Page 38 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Home
80. P7001139 Cable assy for one SLC96 channel bank 20 ft P7000859 Cable assy for one SLC5 channel bank 8 ft P7001136 Cable assy for one SLC5 channel bank 20 ft P7000937 Cable assy for one channel bank generic applications 8 ft Note Each channel bank position on the panel has a maximum capacity of 11 4 Order Part No 535133 DC power cable kit as required Provides two 2 12 long cables to connect between a List 11 12 13 or 14 power shelf and the DC input terminals of one 1 Ring amp Distribution Module 5 For SLC 96 or SLC Series 5 applications order battery cable kits as required from the following table These mate with the battery connectors provided on the power shelf ORDERING CODE DESCRIPTION P7000529 Anderson connector kit for 1 battery string rated up to 60 Up to 3 kits can be installed in the power shelf P7001140 Battery cable kit for SLC96 legacy power shelf Molex connectors for 2 battery strings Up to 3 cable kits can be installed in the power shelf P7001142 Battery cable for SLC5 legacy power shelf Molex connectors for 2 battery strings Up to 3 cable kits can be installed in the power shelf 6 Spare parts for the AP6C57EA EB Ring amp Distribution Module can be ordered as required from the following table ORDERING CODE DESCRIPTION A0885525 1 33A Alarm SAN O Fuse A0885530 3A Alarm SAN O Fuse A0885531 5A Alarm SAN O Fuse A088553
81. Provides five 5 GMT Fuse Distribution Cables one per fuse position Each cable is 12 long 16 AWG terminated on one end with a mating connector that plugs into the shelf GMT fuse connector and left un terminated at the remaining end for connection to customer loads Provides one 1 battery shunt Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via front access terminal block connections Conduit openings are provided on side panel in front of mounting angle Included are two control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Restrictions None Ordering Notes 8 9 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order two 2 List 40 120VAC or two 2 List 41 208 240VAC per List 7 Power Shelf If Molex connector AC input is required order one 1 List 42 or 46 per List 6 Power Shelf If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution and battery disconnect positions order circuit breakers as required per Table 5 Note For battery disconnect positions Electric
82. R 57 GO BACK TO MENU TREE BEGINNING RINGER ALARM MENU RINGER S P L R 54 FAILURE 1 2 GO TO MAIN ALARM MENU RINGER S P L R IS DUPLICATED 58 RINGER S P L R NO RESPONSE GO TO MAIN ALARM MENU GO BACK TO MENU TREE BEGINNING 59 N GO BACK TO MENU TREE BEGINNING ALARM LIMIT aaaaaA NOW AT aaaaaA ALARM LIMIT aaaaaA NOW AT aaaaaA ALARM LIMIT aaaaaA NOW AT aaaaaA ALARM LIMIT hh mm NOW AT hh mm ALARM LIMIT 81 NOW AT 1 To Sheet 4 Page 77 of MIDPOINT ALARM MENU MIDPOINT D R 5 ALARM LIMIT vv vv V 70 1 ALARM 45 NOW AT w w V 71 MIDPOINT D R S Hi Pj ALARM LIMIT vv vv V 2 ALARM 4 NOW AT vv vv V MIDPOINT D R S H ALARM LIMIT wv vv V 72 LO s ALARM 66 Now AT w wv MIDPOINT D R 5 ALARM LIMIT wv vv V 73 LO 2 ALARM 66 NOW AT w w V MIDPOINT D R 5 74 NO SIGNAL 4 GO TO MAIN ALARM MENU 2 GO BACK TO MENU TREE 1 BEGINNING 105 From Sheet 3 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21
83. RM MENU or NORMAL DISPLAY MENU This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited Syst Spec No 589200300 Model XP4890 em Application Guide SAG589200300 Issue AM September 21 2009 OL ILIUM BINARY INPUT IS OP CL SPECIAL FUNCTION SF IS ACTIVE GO TO FUNCTION MENU GO BACK TO MENU TREE BEGINNING 76 7 78 80 82 83 1 2 MAIN ALARM MENU 1PANEL FUSE OR BREAKER ALARM or PANELS FUSE OR BREAKER ALARM AC POWER TO 1 PCU HAS FAILED or AC POWER TO PCUs HAS FAILED or ALL AC POWER HAS FAILED 1 PCU HAS FAILED or PCUs HAVE FAILED or NO PCUS ARE IN INVENTORY 1 DIST PANEL HAS FAILED or DIST PANELS HAVE FAILED or NO DIST PANELS ARE IN INVENTORY 1 LVD IS OPEN or LVDs ARE OPEN LVDs ARE INHIBITED 1 RELAY BOARD HAS FAILED or RELAY BOARDS HAVE FAILED or CONTROLLER RELAYS INOPERATIVE 1 RINGER HAS FAILED or RINGERS HAVE FAILED or NO RINGERS ARE IN INVENTORY CONTROLLER POINTER REQUEST CONTROLLER TOO MANY NODES CONTROLLER NODE IS UNIDENTIFIED CONTROLLER clock FAILURE CONTROLLER MEMORY FAILURE
84. TR via the MCA s Control Panel or Web Interface A PCU fail alarm is NOT issued Local Controls See User Manual for complete descriptions Location Name Description Type MCA 4 Function Select Up Increase Function Set Yes Pushbutton Switch Control v Function Select Down Decrease Function Set No Pushbutton Switch Panel Function Set Enter Pushbutton Switch Page 74 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide Spec No 589200300 Model XP4890 SAG589200300 Issue AM September 21 2009 3 1 7 Local Status and Alarm Indicators See User Manual for complete descriptions Location NAME Description Type MCA Control Panel Message Display Shows Active Alarms or SYSTEM OK Various Measurement Items and Values Various Inventory Items Various Adjustment Items and Values Various Operation Items Various Configuration Items and Settings See Paragraph 3 1 8 MCA Display MAJOR LED flashing red MINOR LED red AC LED green red EQ LED yellow BATTERY LED yellow red 3 1 8 D
85. a constant power source depending upon load demands Transition between source types is completely automatic e Constant Voltage Source For any initial output voltage setting from 47 to 58 volts output voltage remains constant regardless of load This is the normal operating condition in which loads are being supplied and batteries are float charged PCUS will operate as a constant voltage source unless load increases to the point where the product of load current and output voltage equals the specified full output power rating e Constant Power Source As load increases above specified full output power rating output current continues to increase but output voltage decreases as required to maintain constant output power This will continue until output current reaches a predetermined non adjustable limit Load demands above this point result in output voltage dropping rapidly to maintain current and power within their limits Current Limit Mode With the system set to the Current Limit mode the PCUs will operate as a constant voltage source or a constant current source depending upon load demands Transition between source types is completely automatic e Constant Voltage Source For any initial output voltage setting from 47 to 58 volts output voltage remains constant regardless of load This is the normal operating condition in which loads are being supplied and batteries are float charged PCUS will operate as a constant voltage source
86. ace 2 Method 2 Manually Initiated Timed Equalize A user manually places the system into the Equalize mode via the MCA interface The system automatically returns to the Float mode after a preset programmable time period 3 Method 3 Automatic Equalize THE AUTOMATIC EQUALIZE FEATURE IS INTENDED FOR USE ONLY WITH WET CELL BATTERIES USING THIS FEATURE WITH VALVE REGULATED BATTERIES IS NOT RECOMMENDED This feature can be enabled or disabled by a user via the MCA The default state is disabled The Automatic Equalize feature is a time based function that is controlled by a customer selectable multiplier and by the Battery on Discharge BOD alarm setpoint The MCA s default setting is for a multiplier of zero which disables the Automatic Equalize feature When the Automatic Equalize feature is enabled if system voltage drops to less than the BOD alarm setpoint the MCA initiates a timing cycle to measure the discharge time period The MCA requires at least 15 minutes of continuous BOD alarm in order to prevent nuisance equalization cycles When system voltage rises to above the BOD alarm setpoint the MCA ends the discharge timing cycle and assuming a minimum of 15 minutes has elapsed places the PCUs into the equalize mode for a customer selectable multiple of the discharge time period the discharge time period includes the initial 15 minutes Page 64 of 105 This document is property of Emerson Network Power Energy Systems
87. al Trip white handle circuit breakers are not recommended For bullet nose distribution and battery disconnect positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above 10 Order one 1 Load lug two hole No 10 bolt clearance holes on 5 8 centers and one 1 Load Return lug two hole No 10 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 11 For GMT alarm type fuse distribution positions order fuses as required per Table 7 12 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 4 6 and 7 Power and Distribution Shelves in the ACCESSORY INFORMATION section Page 17 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 List 11 23 Front Access Power and Distribution Shelf List of Parts with Load Shunt Dual AC Feed Features Provides common equipment for one 1 Integrated Power and Distribution Shelf rated for up to 114A 5250W of power conversio
88. anation of symbols 156 157 158 CONTROLLER PROBE HI 2 IS OFF or CONTROLLER PROBE HI 2 ttt C F or TXM PROBE T HI 2 IS OFF or TXM PROBE T HI 2 ttt C F or DIST PROBE S T HI 2 IS OFF or DIST PROBE S T HI 1 ttt C F or CONTROLLER PROBE LO 1 IS OFF or CONTROLLER PROBE LO 1 ttt C F or TXM PROBE T LO 1 IS OFF or TXM PROBE T LO 1 ttt C F or DIST PROBE S T LO 1 IS OFF or DIST PROBE S T LO 1 ttt C F or CONTROLLER PROBE LO 1 IS OFF or CONTROLLER PROBE LO 1 ttt C F or TXM PROBE T LO 1 IS OFF or PROBE T LO 1 ttt C F or DIST PROBE S T LO 1 IS OFF or DIST PROBE S T LO 1 ttt C F or MIDPOINT D RS H A1 ALARM IS OFF or MIDPOINT D RS H 1 w vvV 159 MIDPOINT D RS H A2 ALARM IS OFF or MIDPOINT D RS H A2 w vvV 160 CONTROLLER PROBE COMPENSATION or PROBE COMPENSATION 164 on DIST PROBE 5 COMPENSATION 172 Page 76 of 105 m o 177 178 179 180 PANEL S DISCONNECT LD BATT vv vv V or 182 LOAD SHED S R DISCON vv vv V LOAD SHED S R DISCON hh mm or LOAD SHED S R NO TIMER or LOAD SHED S R 183 IN hh mm ss PANEL S RECONNECT LD BATT V PANEL S RECONNECT LD BATT MANUALLY or LOAD SHED S R 184 RECON vv vv V 185 190 191 259 TO SHEET 2 MAIN ALA
89. ant power mode Provides adjustments for all MCA alarm and control circuits Adjustment ranges and factory settings as follows All adjustments can be performed locally via the MCA Control Panel and most can be performed remotely via the MCA s Web Interface See Tables 4 and 5 for adjustment parameters 1 Parameter Max Min Default Float Mode Output Volts 58 00 47 00 54 48 High Voltage Shutdown Volts 59 50 48 00 58 50 Power Current Limit Full Load 128 10 Limit Mode High Voltage 1 Alarm Volts 59 00 48 00 55 50 59 00 48 00 56 50 lt High Voltage 2Alarm Volts Low Voltage 1 Alarm Volts 56 00 40 00 51 00 Low Voltage 2Alarm Volts 56 00 40 00 47 00 lt System Total Current Alarm 30000 0 150 Loss of Redundancy Alarm 2 0 1 times the full output rating of 1 PCU PCU Sequencing Delay Seconds 20 0 0 Relay Test Interval Seconds 120 5 45 Number of Redundant PCUs 2 0 0 Table 4 MCA Basic Settings Page 73 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009
90. ations Required DC distribution fuses are included with each cable assembly ordered Page 48 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Order Wire Option provides a connection interface for an analog communication link over a metallic pair with surge protection See Ring amp Distribution Module Installation and User Manuals IM6C57E and UM6C57E for complete specifications Restrictions Use with List 11 12 18 or 14 only Ordering Notes 1 For a Ring amp Distribution Module equipped with two 2 50VA ringers only order AP6C57EA A7000626 2 For a Ring amp Distribution Module equipped with two 2 50VA ringers and the Order Wire option order AP6C57EB A7000796 3 Order distribution cable assemblies as required from the following table Order up to five 5 cable assemblies one per channel bank Required fuses are included with each cable assembly Cable assemblies can be mixed ORDERING CODE DESCRIPTION P7000858 Cable assy for one SLC96 channel bank 8 ft
91. attery strings via locking type plugs Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug All installer s connections are made through the front See Physical Size Information for dimensions Restrictions Shelf accommodates max two 2 PCUs when List 47 is included Ordering Notes Order one 1 List 32 MCA Order PCUS per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order one 1 List 47 120VAC or 48 240VAC per shelf as required for voltage and cord length Note List 47 120VAC line cords are restricted to powering one 1 PCU each Also available are List 40 and 41 If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Page 18 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without t
92. bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 10 For GMT alarm type fuse distribution positions order fuses as required per Table 7 11 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section Page 12 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 List 3 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Load List of Parts Disconnect Dual AC Feed Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Provides 4 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to
93. c and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 D Reduced Load 65 C to 80C 149 F to 176 Home 4 3 2 Storage Temperature Range 40 C to 85 C 40 F to 185 F 4 3 8 Humidity Capable of operating in an ambient relative humidity range of 0 to 95 non condensing 4 3 4 Altitude The maximum operating ambient temperature should be derated by 10 C at an elevation of 10 000 feet above sea level For elevations between 3 000 feet and 10 000 feet derate the maximum operating ambient temperature linearly 4 3 5 Heat Dissipation BTUs Typical Percentage Mode of Full Total Load Active Standby 0 15 15 30 50 25 15 43 100 41 15 56 4 4 Standard Features 4 4 1 Input Protection A Fusing An internal non replaceable 5 ampere fuse is provided in the negative input lead of each Ringing Generator B Low Voltage Inhibit If input voltage decreases below approximately 38 volts non adjustable the Ringing Generator will inhibit Operation will automatically resume when input voltage increases to within normal input voltage range 4 4 2 Output Protectio
94. copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 Distribution Devices Bullet Nose Type Circuit Breakers Each circuit breaker plugs into a single mounting position Ordering Notes 1 Order circuit breakers per Table 5 Note Caution All Shelves A circuit breaker with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Load should not exceed 80 of device rating Caution Caution List 1 2 3 4 21 22 23 24 only The maximum size circuit breaker used in ambient temperatures above 50 C ambient SHALL BE 40 amperes List 6 7 only The maximum size circuit breaker used in ambient temperatures above 50 ambient SHALL BE 50 amperes for distribution and 75 amperes for battery disconnect List 11 12 13 14 only The maximum size circuit breaker or fuse used in ambient temperatures above 50 ambient SHALL BE 50 amperes A circuit breaker or fuse located in the mounting position adjacent to a 40 or 50 ampere circuit breaker or fuse SHALL BE a maximum of 30 amperes Where two 40 or 50 ampere circuit breakers or fuses are used an empty mounting space SHALL BE provided between them 2 Unless otherwise specified circuit breakers shall be mo
95. ctions Shelf accommodates max two 2 PCUs when List 47 is included Ordering Notes 1 2 3 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required Page 19 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 4 N O 5 If AC line cords are required order one 1 List 47 120VAC or 48 240VAC per shelf as required for voltage and cord length Note List 47 120VAC line cords are restricted to powering one 1 PCU each Also available are List 40 and 41 If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Order one 1 Load lug one hole 1 4 b
96. d Level Meter conforming to ANSI 51 4 was used 1 1 8 EMI RFI Suppression PCUs operating in a Power Shelf conform to the requirements of FCC rules Part 15 Subpart B Class B for Radiated and Conducted emissions limits 1 1 9 Surge Protection Compliance with EN61000 4 5 Installation Class 4 and capable of withstanding surges per ANSI IEEE C 62 41 1991 Category B across the input terminals Note This level of protection is a widely used standard for telecommunications power equipment As with all such equipment it is the end user s responsibility to provide an adequately sized Surge Suppression Device at the commercial power service entrance of the building that reduces all incoming surges to levels below the classes categories stated for the equipment 1 1 10 ESD Protection Complies with EN61000 4 2 Level 4 8kV contact 1 1 11 Electrical Fast Transient Burst Immunity Complies with EN61000 4 4 Level 4 1 1 12 Mounting Front and side access are required for wiring Recommended minimum aisle space clearance is 2 6 for the front of the Power Distribution System 1 2 Compliance Information 1 2 1 Safety Compliance Page 54 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy
97. de Number Nominal Percent of PCUs Input of Full Installed Voltage Load Heat Dissipation BTU Hr Input Current Power Efficiency Amperes Factor 25 0 969 73 6 209 50 0 988 83 3 232 100 0 996 87 6 328 110 0 997 87 9 354 120 0 997 88 0 368 128 0 997 87 8 376 zeo 906 904 oss sre 99 o 12 70 2 23s 4m oss ses 216 o os e B Maximum Input Current At 100 of full load with output adjusted to 58 volts DC as measured at the output bus List 56 Model LXP1750 PCUs 60 Hz Input 25 C Ambient Nominal Input Number of Input Current Input Voltage Voltage PCUS Installed Amperes wr c ERE um 208 240 11 2 Page 63 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 2 3 Standard Features 2 3 1 Type of Power Conversion Circuit High frequency 2 3 2 Float Charging Output Mode In this mode of operation system output voltage is constant and output current does not exceed the c
98. de NEC Table 310 16 for copper wire at 90 C conductor temperature operating in ambients of 30 C 40 C 50 C and 65 C was used For other operating ambient temperatures refer to the NEC For operation in countries where the NEC is not recognized follow applicable codes The AC input branch circuit protective device should be of the time delay or high inrush type Equipment grounding conductors must be provided with the AC input conductors supplied to the shelf Frame ground terminals must be connected to earth ground not power system neutral A ring lug must be provided Equipment grounding conductor size is based on recommendations of the NEC Table 250 122 for copper wire If aluminum or copper clad aluminum grounding conductor is used refer to Table 250 122 for increased conductor size For operation in countries where the NEC is not recognized follow applicable codes Page 37 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 5 When List 11 12 13 or 14 is ordered with List 47 AC cords 120VAC only restricted to
99. des top or bottom feed of AC input wiring into the Power Shelf Restrictions Not available with List 40 41 47 or 48 AC Line Cord options Not available on List 6 or 7 if equipped with List 42 or 46 Ordering Notes 1 For top or bottom AC feed order 1 List 43 List 46 AC Input Molex Connector Option 120 208 240VAC List of Parts Features Provides two 2 Molex connectors in a housing on the left hand side of the shelf in front of the mounting angle connector feeds PCUs in mounting positions 1 3 the other connector feeds mounting position 2 For 120 208 240 VAC Option is factory installed Restrictions For use on List 6 and 7 only Not available with List 43 AC Input Vertical Feed Assembly Mating connectors are required Ordering Notes 1 For chassis mounted Molex AC input connectors order one 1 List 42 per List 6 or 7 shelf 2 For mating AC input connectors order from Table 1E List 47 AC Line Cord Kit 120VAC List of Parts Features Provides two 2 AC input cords each equipped with a NEMA 5 15P straight blade plug Each cord powers one 1 PCU Cords are factory installed Blank Module is included to cover 1 unused PCU mounting position NEMA 5 15P Restrictions Each cord assembly is rated to power one 1 PCU only limits shelf to two 2 PCUS total For 120 VAC only Not available with List 43 AC Input Vertical Feed Assembly Page 29 of 105 Thi
100. eater than 75 amperes SHALL HAVE an empty mounting position between it and any other circuit breaker or fuse Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 ambient SHALL BE 50 amperes A circuit breaker or fuse located in the mounting position adjacent to a 40 ampere or 50 ampere circuit breaker or fuse SHALL BE a maximum of 30 amperes Where two 40 ampere or 50 ampere circuit breakers or fuses are used an empty mounting space SHALL BE provided between them Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current one 1 battery shunt and Low Voltage Load Disconnect Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via terminal block connections Conduit openings are provided on side panel in front of mounting angle Provides connections for three 3 battery strings via locking type plugs Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Page 20 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emers
101. ent and one 1 battery shunt Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via front access terminal block connections Conduit openings are provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Restrictions Not a direct replacement for earlier versions of List 2 Earlier versions of List 2 provided a single AC feed To replace a single feed version of List 2 order List 22 Ordering Notes o 5 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order two 2 List 40 120VAC or two 2 List 41 208 240 VAOC per List 2 Power Shelf If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4
102. ent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current one 1 battery shunt and Low Voltage Battery Disconnect Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides one 1 AC input circuit via front access terminal block connections Conduit opening is provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Restrictions None Ordering Notes 1 Direct replacement for earlier versions of List 4 Earlier versions of List 4 provided a single AC feed To replace a single feed version of List 4 order List 24 2 Order one 1 List 32 MCA 3 Order PCUS per List 53 55 or 56 as required 4 Order Ringing Generators per List 72 as required 5 Ifan AC line cord is required order one 1 List 40 120VAC or one 1 List 41 208 240VAC per List 24 Power Shelf 6 If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required 7 Fo
103. equired per Table 7 Page 25 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 12 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section List 24 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Battery List of Parts Disconnect Single AC Feed Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Provides 4 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurr
104. er s Connections Locations and Dimensions List 6 7 AC Input When Equipped With INCID qr P is teddies 95 Installer s Connections Locations and Dimensions List 6 7 DC Distribution and Battery 96 Overall Dimensions List 11 12 13 14 Power 97 Installer s Connections Locations and Dimensions List 11 12 13 14 AC Input Alarm Control amp Referenc ii eeann tiaau anaana a aa daa Aa dae aaa Pa daa aada aa aa Ea de aa e De aa aa aa te daaa eee te ice ee eel cece ce eee ce 98 Installer s Connections Locations and Dimensions List 11 12 13 14 Distribution and Battery 99 Overall Dimensions List 90 91 93 Battery Temperature 100 Overall Dimensions List 92 Temperature Concentrator Module 101 Overall Dimensions Part No 528927 Load Shed Card eee nn nnne ana aa aua 102 Overall Dimensions Part No 528608 Ringing Distribution Module eren 103 RELATED DOCUMENTATION ciii coe 104 REVISION REC OR I M 105 Page 7 of 105 Thi
105. ers to percent of 16 Amperes per PCU with nominal 208 240V input or percent of 8 Amperes per PCU with nominal 120V input Note At 120V nominal input PCUs operate in the Reduced Power Mode In the Reduced Power Mode PCUS provide 1 2 the output current and power available in Full Power Mode Number Nominal Percent Input Heat of PCUs Input of Full Current Dissipation Installed Voltage Load Amperes BTU Hr o om 7 v 26 50 299 100 T0 120 128 o om o 3 _ 575 moz er owe sre _ o os e ox 24 128 soz 1204 1162 oss 363 _ B Maximum Input Current At 100 of full load with output adjusted to 58 volts DC as measured at the output bus List 53 Model LXP1000 PCUs 60 Hz Input 25 C Ambient Nominal Input Number of Input Current Input Voltage Voltage PCUS Installed Amperes mua DERE 208 240 872 72 Page 59 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 2 2 6 Typical Input Data List 55 Model
106. es the load to within 1 of the PCUs rated output currents If the MCA s load sharing feature is disabled for any reason pre programmed slope control in each PCU balances the load to within 10 of their rated output currents The MCA will balance a system of up to 17 PCUs within 5 minutes The MCA s load sharing feature is disabled whenever the system is in current limit the system is delivering more than 97 capacity or the system is delivering less than 396 capacity Page 71 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 2 3 11 Output Current Walk In Output current gradually increases after the system is switched on or AC service is initially supplied or restored as indicated below Load Current Minimum Elapsed Time seconds 20 50 2 5 75 5 0 90 8 0 2 3 12 Cooling Forced Convection Cooling A three speed fan control circuit is provided When the feature is enabled fan operation is determined by ambient temperature and load current as shown in the following table Values show
107. h America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 D Refer to Figure 3 for a curve that represents the typical LXP1000 output power characteristics at various ambient temperatures Output voltage and current limit are set to maximum Model LXP1000 PCU Thermal Power Limit 208 240VMn Typical 70 ow 333W 667W 1000W 60 50 40 uec VOLTS 30 65 20 0 4 8 12 16 20 24 AMPS Model LXP1000 PCU Thermal Power Limit 120Vn Typical 70 ow 167W 333W 500W VOLTS Figure 3 Page 68 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model
108. he written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 9 Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug one hole 1 4 bolt clearance as required for each bullet nose distribution position per Table 2 10 For GMT alarm type fuse distribution positions order fuses as required per Table 7 11 Order Battery connectors as required per Battery Wire Sizes and Connectors List 11 12 13 and 14 Power and Distribution Shelves in the ACCESSORY INFORMATION section 12 For ringing and DC distribution in imbedded subscriber loop carrier systems such as SLC 96 or SLC Series 5 order one 1 APeC57EA EB Ring amp Distribution Module See Accessory Information List 12 23 Front Access Power and Distribution Shelf List of Parts with Load and Battery Shunts Dual AC Feed Features Provides common equipment for one 1 Integrated Power and Distribution Shelf rated for up to 114A 5250W of power conversion and 100A of distribution at ambient temperatures of 50 C or less and 90A at ambient temperatures above 50 All installer s connections are front access Provides 3 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit
109. isclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Overall Dimensions List 92 Temperature Concentrator Module TXM K 1 885 4 0 190 DIA 2 PLACES N 6 586 6 100 j 5 510 B LEFT SIDE RIGHT SIDE Notes 1 All dimensions are in inches 2 Weight in lbs Net 9 oz Shipping 2 lbs 8 oz 3 Finish Off White Page 101 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Overall Dimensions Part No 528927 Load Shed Card H j
110. isplay Presented next are illustrations from the MCA Menu Tree Section 5956 Refer to the latest version of Section 5956 for the most recent MCA Menu Tree See Operation section of the System s User Manual for complete descriptions of menu items Page 75 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 INITIALIZATION MENU THHHHHHHHHHHHHHHE PROCESSED or CONFIG FILE ERROR 3 PROCESSED or NO CONFIG FILE WAS PROCESSED i 4 CHECK VALUES BEFORE STARTING 143 144 146 149 150 151 152 153 154 CONTROLLER PROBE HI 1 IS OFF or CONTROLLER PROBE HI 1 ttt C F or TXM PROBE T HI 1 IS OFF or 155 TXM PROBE T HI 1 ttt C F or DIST PROBE S T HI 1 IS OFF or DIST PROBE S T HI 1 ttt C F SHEET 1 The user navigates the MCA Display using the Keypad on the MCA Control Panel These pages indicate the actual text shown on Lines 1 and 2 of the MCA Display Line 2 also displays applicable message symbols See page 1 for expl
111. ith data required for battery temperature related functions temperature compensated output voltage high and low battery temperature alarms Plugs into Distribution Sense Module DSM no temperature compensated output voltage or into List 92 Temperature Concentrator Module Page 32 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 15ft long cable Home See Physical Size Information for probe dimensions Restrictions Not for connection to MCA digital probe jack J3 For single probe applications order List 91 or List 93 Ordering Notes 1 Order up to eight 8 List 90 per List 92 ordered List 91 Battery Temperature Probe Digital Output List of Parts Features Mounts near the battery to sense battery ambient temperature Plugs into J3 on the MCA Provides MCA with data required for battery temperature related functions temperature compensated output voltage high and low battery temperature alarms 25ft long cable Same as List 93 except for cable length See Physical Size Informati
112. l Fire Protection Association s NFPA National Electrical Code NEC Table 310 16 for wire rated at 90 C conductor temperature operating in ambient temperatures of 40 C 50 C and 65 C was used For other operating ambient temperatures refer to the NEC For operation in countries where the NEC is not recognized follow applicable codes Recommended wire sizes are sufficient to restrict voltage drop to 1 0 volt or less at listed branch current for the loop lengths shown Loop length is the sum of the lengths of the positive and negative leads 1 Page 39 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Wire Size Loop Length Combination Calculated using 40 C Ambient Operating Temperature Home Wire Size Loop Length Combination Calculated using 50 C Ambient Operating Temperature Wire Size Loop Length Combination Calculated using 65 C Ambient Operating Temperature One hole lugs are 1 4 bolt clearance Two hole lugs are 1 4 or No 10 as shown bolt clearance on 5 8 centers Refer to drawing 031110100 for
113. lt peak to peak 2 Typically 10 millivolts rms Does not exceed 100 millivolt rms 2 2 Input Ratings 2 2 1 Voltage A Nominal 120 208 240 volts AC single phase 50 60 Hz with an operating range of 90 175 volts Reduced Power Mode and 176 264 volts Full Power Mode Acceptable input frequency range is 45 to 65 Hz 2 2 2 Harmonic Content Meets EN 61000 3 2 2 2 8 Inrush Current Peak does not exceed 2 times the RMS input current at full load nominal input voltage and for any duration of AC input interrupts Under the above conditions standard AC distribution circuit breakers will not trip Page 57 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 2 2 4 Typical Input Data List 53 Model LXP1000 PCU 50 Hz input 25 ambient A Output initially adjusted to 54 48 volts DC as measured at the shelf output terminals at 50 of full load and nominal input Percent of Full Load refers to percent of 16 Amperes per PCU with nominal 208 240V input or percent of 8 Amperes per PCU with nominal 120V input Note At
114. lug crimping information Use 1 hole lugs for Load connections on List 1 2 3 4 11 12 13 and 14 Use 2 hole lugs for Load connections on List 6 and 7 Use 1 hole lugs for Load Return connections on List 11 12 13 and 14 Use 2 hole lugs for Load Return connections on List 1 2 3 4 6 and 7 5 6 Battery Wire Sizes and Luqs List 1 2 3 4 21 22 23 and 24 Power and Distribution Shelves Features The installer connects lug terminated battery conductors to the terminals provided Captive nuts 1 4 20 on 5 8 centers are provided for installation of customer furnished two hole lugs These terminals are accessed through the cabinet top or rear panel For lug mounting hole size and spacing dimensions refer to the illustration provided in the Physical Size Information section Restrictions All lugs for customer connections must be ordered separately Ordering Notes 1 Battery wire size varies depending on load therefore no specific information is provided for wire size Refer to Table 5 for recommended wire sizes and lugs at rated maximum total distribution load 100 amperes When making connections observe correct polarity 2 For other available lugs and hardware refer to drawings 031110100 through 031110300 Maximum Ambient Loop Loop Current Operating Length Ft Length Ft c js unl Amps Temperature 1 0 Volt Drop 0 25 Volt Drop p tug 40 C 5
115. me Type LED Green AC OK Operation Normal Yellow blinking Being ID d by MCA or au eS communication with MCA lost Red PCU Fail Page 72 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Home 3 MCA 3 1 Standard Features 3 1 1 3 1 2 3 1 3 3 1 4 MCA Interface A Local Via the MCA s Control Panel B Remote Via the MCA s Web Interface See Paragraph 3 2 MCA Local Display Provides digital metering of system load voltage and current individual PCU current and individual load shunts Also displays system alarm messages and adjustment information as detailed in Paragraph 3 1 8 MCA Display MCA Meter Accuracy 0 01 V 0 005 MCA Universal Adjustment Circuit Provides single point control of float equalize battery test thermal runaway management output voltages high voltage shutdown and current limit adjustments Note Should the MCA fail the PCUs remember the float and high voltage shutdown settings last delivered by the MCA The current limit control of each PCU goes to const
116. mode C Flashing Amber Operating in current limit or thermal current limit this generator selected to supply load D Red Failure condition this generator output not available Failure conditions include e Low output voltage due to generator failure e Output voltage exceeds approximately 105 VAC HVSD e Low input voltage Low Voltage Inhibit e Internal temperature exceeds a predetermined limit Over temperature Inhibit e Cooling fan failure or fan rotor blocked Page 87 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 PHYSICAL SIZE INFORMATION Home Overall Dimensions List 1 2 3 4 21 22 23 24 Power Shelves Battery Wiring Entrance Rear NOTES _ 1 All dimensions are in inches 2 Weight In Pounds Net Shipping Shelf 19 Ib 12 oz 25 Ib 4 oz 216 1402 410 902 PCU 5 lb 407 7 lb 13 oz Ring Gen 3lb 80z 510 002 3 Finish Shelf and Module Bodies Bright Zinc Front Panels Textured Cool Gray M500 146
117. ms North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 List 2 23 Power and Distribution Shelf List of Parts with Load and Battery Shunts Dual AC Feed Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Provides 4 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution curr
118. mum wire size is 6 AWG Mating plugs are not provided with the shelf and must be ordered separately Ordering Notes 1 Battery wire size varies depending on load therefore no specific information is provided for selecting a wire size Refer to Table 3B for recommended wire sizes and connectors at rated maximum total distribution load 100A at or below 50 ambient 90A above 50 ambient Current is shown evenly distributed between two battery strings N 1 redundancy Page 41 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Current per Ambient Loop Loop Housing with 75 Amp Battery Operating Length Ft Length Ft 90 C Contact reg Drop 9 pes M fiio Emerson Network Anderson Power Part No Part No 50 40 C 47 11 6 AWG ONEN Shes eripi 45 65 52 13 6 AWG Table 3B Recommended Battery Wire Size and Lug Selection List 11 12 13 and 14 Power and Distribution Shelves Notes for Tables 3B 1 Wire sizes are based on recommendatio
119. n A Current Limiting Output current is limited to approximately 11096 of rated full load non adjustable B Thermal Current Limiting Each Ringing Generator continuously monitors the ambient temperature surrounding the power conversion unit circuit If for any reason such as a high ambient office temperature this temperature increases above approximately 65 C 149 F the Ringing Generator will not shut down Rather the Ringing Generator will limit its maximum output current to maintain the temperature of the power conversion circuit within design parameters Full current capability is restored when the temperature decreases to below approximately 65 149 F Warning The Ringing Generators are rated for continuous operation at full output power up to 65 C 149 F Operation between 65 and 80 149 F 176 F is considered abnormal and should be used on a temporary basis only 1 Temporary Operation at Abnormal Temperature Temporary operation refers to a period of not more than eight consecutive hours per day and a total of not more than 15 days in a year This refers to a total of 120 hours in any given year but no more than 15 occurrences in that one year period C High Voltage Shutdown The Ringing Generator will shut down and lock out if output voltage exceeds approximately 105 VAC RMS non adjustable Manual restart is required Can be restarted locally or via Web Interface Page
120. n and 100A of distribution at ambient temperatures of 50 C or less and 90A at ambient temperatures above 50 All installer s connections are front access Provides 3 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other circuit breaker or fuse Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 50 amperes A circuit breaker or fuse located in the mounting position adjacent to a 40 ampere or 50 ampere circuit breaker or fuse SHALL BE a maximum of 30 amperes Where two 40 ampere or 50 ampere circuit breakers or fuses are used an empty mounting space SHALL BE provided between them Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via terminal block connections Conduit openings are provided on side panel in front of mounting angle Provides connections for three 3 b
121. n are typical LXP1000 LXP1500 LXP1750 Ambient Fan Operation C Vin Vin Vin Vin Vin Vin 120 240 120 240 120 240 Always high speed 35 Go to medium speed if now low speed amp currrent gt 5 7A gt 11 0 gt 8 6A 16 54A 8 6A 19 32A 32 Go to medium speed if presently high speed Go to medium speed if current gt 5 7 gt 11 0 gt 8 6A 16 54A 8 6A 19 32A 7 Go to low speed if current lt 5 33A lt 10 25A lt 8 0 lt 15 38A lt 8 0A lt 17 96A Go to medium speed if currrent gt 5 7 gt 11 0 gt 8 6 gt 16 54A gt 8 6A gt 19 32A 10 Always medium speed 17 Hold present speed 20 Always high speed The fan control feature can be enabled or disabled by a user via the MCA the fans operate at high speed at all times The default state is disabled When disabled Should a PCU fan fail the STATUS indicator will go red and the MCA will generate a fan fail alarm Note When the fan speed control feature is enabled the PCUs individually use their internal temperatures and output currents to control fan speed It is therefore possible that in a system with many PCUS and under certain conditions fans in the various PCUS will operate at different speeds 2 3 13 Local Controls None 2 3 14 Local Status and Alarm Indicators Location Na
122. n back of door 0 75 0 75 0 75 1 4 20 x 1 2 Threaded Stud 1 Place per Distribution Position L Factory supplies lug Note All dimensions are in inches mounting hardware Page 99 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Overall Dimensions List 90 91 93 Battery Temperature Probes PROBE ATTACH TO NEGATIVE BATTERY TERMINAL CLEARANCE FOR 5 16 HARDWARE CREDE 180 3 00 gt LIST 90 ANALOG PROBE 0 25 DIA NI P E le 3 00 0 75 e 2 25 i J mm TL oss 300 List 91 30 List 93 LIST 91 93 DIGITAL PROBE NOTE All dimensions are in inches Page 100 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or d
123. n owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 589200300 Power and List 53 55 56 PCU Distribution Shelf List 40 List 41 List 42 List 43 List 46 List 47 List 48 List 50 List 73 List 80 List 81 List 90 Other Options AC Line Cord Kit 120VAC for List 1 2 3 4 6 7 21 22 23 24 AC Line Cord Kit 208 240VAC for List 1 2 3 4 6 7 21 22 23 24 Molex Connecor AC Input Option for List 6 7 AC Vertical Feed Assembly Molex Connecor AC Input Option for List 6 7 AC Line Cord Kit 120VAC for List 11 12 18 14 AC Line Cord Kit 240VAC for List 11 12 13 14 Blank Module Replacement Ringing Generator for List 72 Cable Local Computer Access Cable MCA Control Bus Battery Temperature Probe List 91 93 List 92 List 94 List 95 93 Battery Temperature Probe Battery Temperature Probe Concentrator Module TXM TXM Interface Cable 10 ft TXM Interface Cable 15 ft List 72 50VA Redundant Ringing Generator Module List 32 MCA See ACCESSORY INFORMATION Section for Distribution Devices Recommended Wire Sizes
124. n places all PCUs in the Battery Thermal Runaway Management mode of operation 4 Equalize Activation of an associated condition places all PCUs in the Equalize mode of operation 5 Battery Test Activation of an associated condition places all PCUs in the Battery Test mode of operation 6 Function Test Mode Activation of an associated condition blocks activation of any other Special Function definitions Permits testing of special functions such as High Voltage Shutdown or Emergency Stop without affecting operation of the system The binary inputs can be configured by the user to activate when contacts open or when contacts close B External System Voltage Meter Reading Leads can be extended from the MCA to an external voltage source This is the voltage source the MCA monitors for system alarms and displays as System Output Voltage 3 1 10 External Alarm Circuits The MCA provides six 6 external alarm relays each with one set of Form C contacts A Contact Rating 2A at 30 VDC B Description of Operation The MCA provides 10 programmable Alarm Definitions Each Alarm Definition is programmed to alarm for selected conditions then each external alarm relay is programmed to change state if a specific Alarm Definition alarms 3 2 Web Interface System Status Controtier Aan E Banor narmi System Mode Float vor Alarme Bl Retay Alarms Bl Temperature Alarms Bl LVO Alarms PCU Mode Constant Power Bl
125. nc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 List Part E ud 72 1 487112200 Ringing Generator Module complete includes 2 P N 487112100 Ringing Generators T3 487112100 Replacement Ringing Generator complete 90 1 521262 Probe battery temp analog 15 ft 35 i sears Cable interface MCA IR Page 53 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 SPECIFICATIONS m Note For all Part No 528927 Load Shed Card specifications refer to Section 5985 Section 5985 can be accessed via the CD Electronic Documentation Package furnished with your system 1 SYSTEM 1 4 Environmental Ratings 1 1 1 Operating Ambient Temperature Range A Operational 40 C to 80 C 40 F to 176 B Start 30 C to 80 C 22 F to 176 C Specification Compliant Full Output 20
126. nd to restart at approximately 264 volts AC 2 3 6 Output Protection A Power or Current Limiting The system can be set for Power Limiting or Current Limiting Factory default is for Power Limiting 1 Power Limiting When the system is set for Power Limiting the maximum power delivered by each PCU is limited the value shown in the following table PCU Model 208 240V In 120VAC In LXP1000W 1000W 500W LXP1500W 1500W 750W LXP1750W 1750W 750W Page 65 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 2 Current Limiting When the system is set for Current Limiting the maximum Home current delivered by the system can be programmed from 10 to 110 of total system capacity The MCA automatically adjusts the current limit circuit on each PCU so that this value is not exceeded If a PCU fails the MCA automatically resets each remaining PCU s current limit point to maintain this value The MCA also ensures that the current limit circuit on any PCU is not set above 110 of its capacity The
127. ng is provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Restrictions None Ordering Notes 1 a amp 9 0 Direct replacement for earlier versions of List 3 Earlier versions of List 3 provided a single AC feed To replace a single feed version of List 3 order List 23 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If an AC line cord is required order one 1 List 40 120VAC or one 1 List 41 208 240VAC per List 23 Power Shelf If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above 10 Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 11 For GMT alarm type fuse distribution positions order fuses as r
128. ns of the American National Standards Institute ANSI approved National Fire Protection Association s NFPA National Electrical Code NEC Table 310 16 for wire rated at 90 conductor temperature operating in ambient temperatures of 40 50 and 65 was used For other operating ambient temperatures refer to the NEC For operation in countries where the NEC is not recognized follow applicable codes Recommended wire sizes are sufficient to restrict voltage drop to the voltage shown in the column heading or less at the current shown in the Current per Battery String column for the loop lengths shown in this column Loop length is the sum of the lengths of the positive and negative leads Use hand crimping tool Anderson Part No 1309G4 Contacts should be crimped to the specifications given in the manufacturer s instructions furnished with the crimp tool or connector External Alarm Reference and Control Wire Sizes Features External Alarm Reference and Control connections are made to TB1 on the MCA 28 to 16 screw Clam 22 AWG for Loop Lengths Up to 200 ft AWG P 18 20 AWG for Loop Lengths Over 200 ft Table 4 Recommended Alarm Reference and Control Wire Size TB1 and TB2 on MCA Page 42 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any
129. nstallation Instructions Section 5978 User Instructions Section 5979 Color MCA Menu Tree Section 5956 Instructions Section 5940 Load Shed Card Instructions Section 5985 Ringing Distribution Module Instructions Section 5991 Schematic Diagram 50589200300 Wiring Diagram T589200300 Lug Detail Drawings 031110100 031110200 031110300 Page 104 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide Spec No 589200300 Model XP4890 REVISION RECORD Home SAG589200300 Issue AM September 21 2009 Change Issue Number Description of Change Date Approved ECO AA LLP205185 New 2 24 06 J Kirkpatrick 2 14 06 J Rader AB LLP205652 Added Part No 528927 Load Shed Card 5 1 06 J Kirkpatrick Added tables to List 80 and 81 descriptions 5 1 06 J Jasko Updated MCA Menu Tree to version 3 0 AC LLP206112 Added List 95 Added Part No 110982 fuse to 5 17 06 J Kirkpatrick Field Replaceable Components 5 17 06 Clause AD LLP206694 Added List 72 and 73 Added Part No 528608 10 19 06 J Kirkpatrick and 529034 t
130. nte theses 29 List 48 AC Line Cord Kit 240VAC ssssssssssseseseseen eee nnne nnne nnne nnns nrn arena 30 uae ME TID 30 List 53 1000 Watt Power Conversion Unit PCU ssssssssesesee eee 30 List 55 1500 Watt Power Conversion Unit PCU ssssssssssssesse eene 30 List 56 1750 Watt Power Conversion Unit PCU esssssssssseeee eene 31 List 72 Model LXRO50 Redundant Ringing Generator 2 31 List 73 Replacement Ringing 31 Page 5 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 List 80 Local Computer Access Cable ener enne 32 List 81 RJ 45 MCA Control Bus 32 List 90 Battery Temperature Probe Analog 22 32 List 91 Battery Temperature Probe Digital
131. o Accessories Revised Menu 10 19 06 M Valerian Tree to MCA version 3 1 Added MCA version requirement to P N 528927 Load Shed Card description AE LLP207301 Added SNMP option Expanded List 32 MCA 1 28 07 J Kirkpatrick feature and ordering information Revised 1 29 07 J Jasko Menu Tree to MCA version 4 0 Updated contents of P N 534637 fan kit Corrected List 72 frequency tolerance AF LLP208124 Revised Menu Tree to MCA version 4 1 0 x 4 4 07 J Kirkpatrick 4 4 07 J Jasko AG LLP208425 Added Lists 11 12 13 14 47 48 5 9 07 J Kirkpatrick 5 9 07 J Jasko AH LLP208652 Added AP6C57EA EB Ring amp Distribution 6 19 07 J Kirkpatrick Module to Accessories 6 19 07 J Jasko AJ LLP208807 Added List 6 7 53 56 List 55 was P N 486534200 List 1 4 now dual AC feed List 40 and 41 now two cords each Removed input data for multiple PCUs P N 534903 ae es GMT fuse assembly in List 1 2 3 4 11 12 13 and 14 was P N 528185 Ventilation rear spacing requirement now one inch AK LLP210314 Added List 21 22 23 24 42 46 List 40 and 04 29 08 J Kirkpatrick 41 now one cord each AL LLP210958 List 90 Temp Probe part number corrected 06 17 08 John Jasko List 6 and 7 Load Return changed from two AM LLP212945 threaded studs to a threaded stud and an 09 21 09 John Jasko alignment pin John Jasko Oct 7 2009 Qral Lyons Oct 8 2009 Emerson Network Power Energy Systems North America Inc 1122 F Street Lorain
132. of the lengths of the positive and negative leads Two hole lug 1 4 bolt clearance hole 5 8 centers Refer to drawing 031110100 for lug crimping information Battery Wire Sizes and Lugs List 6 and 7 Power and Distribution Shelves Features The installer connects lug terminated battery conductors to the disconnect device mounting position and the ground busbar The disconnect device mounting position provides 2 10 32 threaded holes on 5 8 centers for installation of a customer furnished two hole lug The ground busbar provides 1 10 32 x 1 2 threaded stud and 1 alignment pin on 5 8 centers for installation of a customer furnished two hole lug Maximum size of wire to be connected is 2 AWG For lug mounting hole size and spacing dimensions refer to the illustration provided in the Physical Size Information section Restrictions All lugs for customer connections must be ordered separately Ordering Notes 1 The rating of the disconnect device determines the wire size requirements For wire size and lug selection refer to Table 2 2 For other available lugs and hardware refer to drawings 031110100 through 031110300 Battery Wire Sizes and Connectors List 11 12 13 and 14 Power and Distribution Shelves Features Battery connections are made to locking type plugs Connections are provided for three 3 battery strings These connections are accessed through the front of the cabinet Restrictions Maxi
133. olt clearance hole and one 1 Load Return lug one hole 1 4 bolt clearance as required for each bullet nose distribution position per Table 2 10 For GMT alarm type fuse distribution positions order fuses as required per Table 7 11 Order Battery connectors as required per Battery Wire Sizes and Connectors List 11 12 13 and 14 Power and Distribution Shelves in the ACCESSORY INFORMATION section 12 For ringing and DC distribution in imbedded subscriber loop carrier systems such as SLC 96 or SLC Series 5 order one 1 AP6C57EA EB Ring amp Distribution Module See Accessory Information List 13 23 Front Access Power and Distribution Shelf with Load and Battery Shunts Low Voltage Load List of Parts Disconnect Dual AC Feed Features Provides common equipment for one 1 Integrated Power and Distribution Shelf rated for up to 114A 5250W of power conversion and 100A of distribution at ambient temperatures of 50 C or less and 90A at ambient temperatures above 50 All installer s connections are front access Provides 3 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating gr
134. on 2U ISD Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar link 2U ISD Assembly cable distribution 2U ISD Contactor 1C SPST 150A 48V Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar link 2U ISD Assembly cable distribution 2U ISD Contactor 1C SPST 150A 48V Assembly shelf 2U ISD Busbar link 2U ISD Kit Mounting 2U ISD Assembly shelf 2U ISD Contactor 1C SPST 150A 48V Kit Mounting 2U ISD Assembly shelf 2U ISD Shunt DC 175A 25 mV Busbar load batt Busbar link Assembly cable distribution 2U ISD Assembly shelf 2U ISD Shunt DC 175A 25 mV Busbar load batt Busbar link Assembly cable distribution 2U ISD Assembly shelf 2U ISD Shunt DC 175A 25 mV Busbar com link Busbar LVLD link Assembly cable distribution 2U ISD Contactor 1C SPDT 150 Amp 48VDC Page 51 of 105 SAG589200300 Issue AM September 21 2009 SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 List Part 536650 528229 534748 534749 534621 128824 535190 528229 528242 528259 528277 535190 528229 528242 528262 528277 535190 528229 528242 528260 528277 128284 535190 528229 528242 528261 528277 128284 535213 246836600 244823100 541191 535214 525075 535211 534840 534841 1 2 2 1 525008 1 Assembly shelf 2U ISD
135. on Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Allinstaller s connections are made through the front See Physical Size Information for dimensions Restrictions Shelf accommodates max two 2 PCUs when List 47 is included Ordering Notes co N ee Order one 1 List 32 MCA Order PCUS per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order one 1 List 47 120VAC or 48 240VAC per shelf as required for voltage and cord length Note List 47 120VAC line cords are restricted to powering one 1 PCU each Also available are List 40 and 41 If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug one hole 1 4 bolt clearance as required for each bullet nose distribution position per Table 2 10 For GMT alarm type fuse distribution positions
136. on for probe dimensions Restrictions For use in single probe applications only Cannot be used with a List 92 TXM For multiple probe applications with a TXM order List 90 probes Ordering Notes 1 Order one 1 List 91 or List 93 per system List 92 Temperature Concentrator Module TXM List of Parts Features Provides the system MCA with a means of monitoring up to eight 8 List 90 battery temperature probes Plugs into J3 on the MCA System MCA can be set to compensate on the hottest probe the average temperature of all connected probes or the lowest numbered probe connected Mounts externally Includes 25 ft cable for interface to MCA connector J3 See Physical Size Information for dimensions See Installation and User Instructions Section 5940 for complete specifications Restrictions Requires List 90 temperature probes Cannot be used with List 91 temperature probes Ordering Notes 1 Order one 1 List 92 per system 2 Order up to eight 8 List 90 analog probes as required 3 Fora shorter interface cable also order List 94 10 ft or 95 15 ft Page 33 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems
137. or bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current and one 1 battery shunt Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides one 1 AC input circuit via front access terminal block connections Conduit opening is provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Restrictions None Ordering Notes 1 S dE Mo UM 9 0 Direct replacement for earlier versions of List 2 Earlier versions of List 1 provided a single AC feed To replace a single feed version of List 2 order List 22 Order one 1 List 32 MCA
138. order fuses as required per Table 7 11 Order Battery connectors as required per Battery Wire Sizes and Connectors List 11 12 13 and 14 Power and Distribution Shelves in the ACCESSORY INFORMATION section 12 For ringing and DC distribution in imbedded subscriber loop carrier systems such as SLC 96 or SLC Series 5 order one 1 AP6C57EA EB Ring amp Distribution Module See Accessory Information List 14 23 Front Access Power and Distribution Shelf with Load and Battery Shunts Low Voltage Battery List of Parts Disconnect Dual AC Feed Features Provides common equipment for one 1 Integrated Power and Distribution Shelf rated for up to 114A 5250W of power conversion and 100A of distribution at ambient temperatures of 50 C or less and 90A at ambient temperatures above 50 All installer s connections are front access Provides 3 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other circuit breaker or fuse Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50
139. ork Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 ACCESSORY DESCRIPTIONS Recommended Wire Sizes and Branch Circuit Protection AC Input Wire Sizes Branch Circuit Protection Features Screw compression type terminals are provided for connection of AC input wiring These terminals are accessed through the front of the Power Shelf A threaded stud 8 32 is provided for installation of frame ground wiring The stud is accessed through the front of the Power Shelf Ordering Notes 1 2 3 For Lists 1 2 3 4 6 7 11 12 13 and 14 refer to Tables 1A 120VAC and 1B 208 240VAC for recommended wire sizes and branch circuit protection For Lists 21 22 23 and 24 refer to Tables 1C 120VAC and 1D 208 240VAC for recommended wire sizes and branch circuit protection Notes referenced in tables are found after Table 1E 1 2 3 4 6 7 11 12 13 14 120 VAC Input Two AC Input Circuits Recm Line Terminals Ground 9 9 Ambient Branch 90 Operatin t E 90 Wire Size Temperature Feeg
140. orth America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Installer s Connections Locations and Dimensions List 6 7 AC Input Alarm Control amp Reference Note See next page for List 6 and 7 equipped with List 46 AC option AC INPUT FRONT VIEW M Feeds PCUs in ALARM REFERENCE amp CONTROL Located on MCA inside the cabinet Alarm Outputs amp Control Inputs 2 Positions 1 amp 3 E 1 H Ll Feeds PCU in 2 Position 2 So Sl TB2 TB1 FRAME GROUND No 8 32 x 0 563 Threaded Stud 98 CUTAWAY VIEW CABINET RIGHT SIDE Battery Temperature Probe J8 Web Interface Ethernet Note All dimensions are in inches Page 94 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Installer s Connections Locations and Dimensions List 6 7 AC Input When Equipped With List 46
141. otes 1 For 208 240VAC operation in List 21 22 23 or 24 shelves order one 1 List 40 per Power Shelf 2 For 208 240VAC operation in all other List number shelves order two 2 List 40 per Power Shelf List 42 AC Input Molex Connector Option 120 208 240VAC List of Parts Features Provides two 2 six inch long AC input cables terminated with Molex connectors Cables extend from left hand side of shelf in front of mounting angle cable feeds PCUs in mounting positions 1 and 3 the other cable feeds mounting position 2 For 120 208 240 VAC Option is factory installed Restrictions For use on List 6 and 7 shelves only Not available with List 43 AC Input Vertical Feed Assembly Mating connectors are required Ordering Notes 1 For Molex AC input connectors on cables order one 1 List 42 per List 6 or 7 shelf 2 For mating AC input connectors order from Table 1E Page 28 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 List 43 AC Input Vertical Feed Assembly Features Provi
142. ounting hardware CD Y 4 GMT Distribution Fuse Connections mating connectors required cables 0 75 with connectors are furnished AN as standard Iw a 0 75 E DLI a XU J r e D 10 32 x 1 2 Threaded Stud pope Lug Alignment Pin 1 Place per Lug 1 Place per Distribution Return Load Factory supplies lug Position mounting hardware Note All dimensions are in inches Page 96 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Overall Dimensions List 11 12 13 14 Power Shelves NOTES 1 All dimensions are in inches 2 Weight In Pounds Shipping 25 Ib 4 oz 4 Ib 9 oz Shelf 19 Ib 12 oz 2 Ib 14 oz PCU 51 4 oz 7 lb 13 oz 3lb 80z 516 002 3 Finish Shelf and Module Bodies Bright Zinc Front Panels Textured Cool Gray M500 146 4 Mounting Position 1 shown with optional List 72 Ringing Generator
143. owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 temperature If the MCA s regulation feature is disabled for any reason steady Home state regulation is 1 as controlled within the PCUS B Dynamic Response For any step load change within the range of 20 to 100 of rated output current per Telcordia GR 947 CORE the maximum voltage transient will not exceed 5 of the initial steady state voltage Recovery to within 0 7 of the initial steady state voltage does not exceed 30 milliseconds recovery to within 0 5 of the initial steady state voltage does not exceed five seconds and recovery to within 0 02 of the initial steady state voltage does not exceed 20 seconds 2 1 4 Filtering with or without battery Typical readings were taken at nominal input voltage nominal output voltage 50 load and 25 C 77 F ambient A Voice Band Noise Complies with Telcordia GR 947 CORE 1 Typically 13 dBrn with C message weighting Does not exceed 26 dBrn C 2 Typically 0 100 millivolt psophometric Does not exceed 1 millivolt psophometric B Wide Band Noise Complies with Telcordia GR 947 CORE 1 Typically 150 millivolt peak to peak Does not exceed 250 millivo
144. qualize and Battery Test voltage ranges are the same as without battery charge temperature compensation Using battery and equipment manufacturers recommendations the user selects the following temperature compensation curve parameters via the MCA Figure 1 details a user defined Temperature Compensation Curve 1 The temperature compensation slope in volts C Adjustable from zero to 200 millivolts C Factory set at OV C NO TEMPERATURE COMPENSATION 2 The maximum voltage limit in volts DC Adjustable from float up to 58 00 volts DC but automatically limited to one volt below the High Voltage Shutdown setting Factory set at 56 50 volts DC 3 The minimum voltage limit in volts DC Adjustable from float down to 47 00 volts DC Factory set at 52 00 volts DC Page 55 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 Home A MAXIMUM COMPENSATION Adjustable from 2 Float to 58 0V max E
145. r bullet nose distribution positions order circuit breakers as required per Table 5 8 For bullet nose distribution positions order fuses as required per Table 6 9 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Page 26 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 10 Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 11 For GMT alarm type fuse distribution positions order fuses as required per Table 7 12 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section List 32 Model LXC300 Meter Control and Alarm Assembly MCA List of Parts Features Consists of one 1 Model LXC300 Meter Control and Alarm assembly MCA Refer to SPECIFICATIONS for a description of MCA functions e Mounts in Main Power Shelf Controls and monito
146. rack Restrictions Not a direct replacement for earlier versions of List 1 Earlier versions of List 1 provided a single AC feed To replace a single feed version of List 1 order List 21 Ordering Notes o OD Order one 1 List 32 MCA Order PCUS per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order two 2 List 40 120VAC or two 2 List 41 208 240VAC per List 1 Power Shelf If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 10 For GMT alarm type fuse distribution positions order fuses as required per Table 7 11 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section Page 11 of 105 This document is property of Emerson Network Power Energy Syste
147. rcuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 50 amperes Provides 1 mounting position for bullet nose Battery Disconnect Fuseholder or Circuit Breaker 3 to 100A TPS TLS Type Fuse or 1 to 100A Bullet Nose Type Circuit Breaker Caution A circuit breaker with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device A fuse with a rating greater than 70 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Page 16 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 Caution The maximum size circuit breaker used in ambient temperatures above 50 C ambient SHALL BE 75 amperes The maximum size fuse used in ambient temperatures above 50 C ambient SHALL BE 70 amperes Provides 5 mounting positions for GMT type distribution fuses 30 max total 1 15A fuses Caution The maximum size fuse used in ambient temperatures above 50 C ambient SHALL BE 10 amperes
148. rent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides one 1 AC input circuit via front access terminal block connections Conduit opening is provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Restrictions None Ordering Notes 1 a d um 9 0 Direct replacement for earlier versions of List 1 Earlier versions of List 1 provided a single AC feed To replace a single feed version of List 1 order List 21 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If an AC line cord is required order one 1 List 40 120VAC or one 1 List 41 208 240VAC per List 21 Power Shelf If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breake
149. rica Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 List 23 23 Power and Distribution Shelf with Load and Battery Shunts Low Voltage Load List of Parts Disconnect Single AC Feed Features Provides common equipment for 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Provides 4 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 C ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current one 1 battery shunt and Low Voltage Load Disconnect Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides one 1 AC input circuit via front access terminal block connections Conduit openi
150. rica Inc is strictly prohibited System Application Guide SAG589200300 Spec No 589200300 Model XP4890 Issue AM September 21 2009 10 For GMT alarm type fuse distribution positions order fuses as required per Table 7 11 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section List 6 23 Power and Distribution Shelf with Battery Shunt Dual AC Feed List of Parts Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and 80A of distribution at ambient temperatures of 50 or less and 60A at ambient temperatures above 50 Provides 3 mounting positions for bullet nose Load Distribution Fuseholders or Circuit Breakers 3 to 100A TPS TLS Type Fuses or 1 to 100A Bullet Nose Type Circuit Breakers Unless otherwise specified circuit breakers or fuses will be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 ambient SHALL BE 50 amperes Provides 1 mounting position for bullet nose Battery Disconnect Fuseholder or Circuit Breaker
151. rs as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above 10 Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 11 For GMT alarm type fuse distribution positions order fuses as required per Table 7 12 Order Battery lugs as required per Battery Wire Sizes and Lugs List 1 2 3 and 4 Power and Distribution Shelves in the ACCESSORY INFORMATION section List 22 23 Power and Distribution Shelf List of Parts with Load and Battery Shunts Single AC Feed Features Provides common equipment for one 1 Integrated Power amp Distribution Shelf rated for up to 114 Amperes 5250W of power conversion and up to 100A of distribution Page 23 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Provides 4 mounting positions f
152. rs the following LXP equipment Component Maximum Number PCU 17 in up to 3 shelves Distribution Cabinet DSM 4 List 72 Redundant Ringing Generator Module 4 2 generators ea Load Shed Card P N 528927 4 MCA maximum quantities may be otherwise restricted in your system Standard equipment includes a local user interface as well as a Web Interface for browser based remote access via an Ethernet port be equipped with a Battery Reserve Time Prediction Option With this software option installed the MCA monitors battery voltage during discharge and uses a Telcordia defined adaptive algorithm to predict remaining time before a user selectable voltage is reached Battery Reserve Low alarm alerts user when the predicted remaining time is less than a user selectable alarm setpoint The option also provides a Battery Health Alarm which alerts user when batteries are nearing end of life be equipped with an SNMP Option With this software option installed the MCA supports SNMP v2 Simple Network Management Protocol interface in a TCP IP network Communications to and from the MCA is accomplished with a MIB Management Information Base browser via the MCA Ethernet port Ordering Notes Order one 1 List 80 if local PC access to Web Interface is required 3 Order Battery Reserve Time Prediction Option if required 4 Order SNMP Option if required List 40 AC Line Cord Kit 120VAC
153. s document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 Issue AM September 21 2009 System Application Guide Spec No 589200300 Model XP4890 ORDERING INFORMATION Home List Options Order the following by the items Part Number as specified in the following table When viewing electronically click on the List to jump to the detailed description page List No Part Number Description Mounting Positions 1U 1 3 4 58920030001 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Load Shunt dual AC feed 2U 1 58920030002 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts dual AC feed 2U 58920030003 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts amp LVLD dual AC feed 2U I gt 58920030004 Integrated Power amp Distribution Shelf 23 up to 114 Amps 5250W of power conversion equipped with Load amp Battery Shunts amp LVB
154. s document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Ordering Notes 1 For 120VAC operation order one 1 List 47 per Power Shelf Order the required length from the following table Length Part Number 6 ft 534841 10 ft 534840 List 48 AC Line Cord Kit 240VAC List of Parts Features Provides two 2 AC input cords each equipped with a NEMA 6 20P straight blade plug Cords are factory installed Restrictions BE NEMA 6 20P or 7 For 240 VAC only Not available with List 43 AC Input Vertical Feed Assembly Ordering Notes 1 For 240VAC operation order one 1 List 48 per Power Shelf Order the required length from the following table Length Part Number 6 ft 534843 10 ft 534842 List 50 Blank Module List of Parts Features Fills one PCU mounting position Ordering Notes 1 Order as required List 53 1000 Watt Power Conversion Unit PCU Features Consists of one 1 Model LXP1000 PCU Spec No 486534800 Ordering Notes 1 Shelf accepts up to three
155. sconnect or Low Voltage Battery Disconnect options Ringing An in shelf ringing generator option provides 50VA of continuous ringing power with built in redundancy and transfer capability Page 2 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide Spec No 589200300 Model XP4890 Family Spec No Model Output Voltage Output Capacity System List 53 PCU LXP1000 List 55 PCU LXP1500 List 56 PCU LXP1750 Total Distribution Agency Approval Framework Type Mounting Width Mounting Depth Mounting Height Front Projection Access Expansion Shelves Available Control Color List Options Accessory Options Environment Specification Compliant Full Output Reduced Load SAG589200300 Issue AM September 21 2009 LXP 589200300 XP4890 48VDC nominal 114 Amperes 5 250 Watts max 208 240V 49 Amperes 2250 Watts max 120V 16 7A 58 0VDC to 21 7A 46VDC 1000 Watts max 208 240V 8 35 58 0VDC to 10 85A 46VDC 500 Watts max 120V 25A 58 0VDC to 32 6A 46VDC 1500 Watts max 208 240V 12 5 58 0VDC to 16 3A 46VDC
156. son Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide Spec No 589200300 Model XP4890 LXP1000 ay 834 667 500 333 MAX OUTPUT POWER W 167 LXP1000 0 333 167 MAX OUTPUT POWER W LXP1500 oa eo 1250 1000 750 500 250 LXP1500 N 0 500 250 SAG589200300 Issue AM September 21 2009 Thermal Power Limit Curve 4 208 240Vin Typical 1750 66 1459 1167 875 583 292 0 20 55 40 45 50 55 60 65 70 75 80 4 104 113 122 131 140 149 158 167 176 F NORMAL ABNORMAL CONTINUOUS TEMPORARY OPERATION OPERATION AMBIENT TEMPERATURE R nte Thermal Power Limit Curve x 120Vin Typical 75055 500 250 065 20 40 45 50 55 60 65 70 75 80 4 104 113 122 131 140 149 158 167 176 NORMAL ABNORMAL CONTINUOUS TEMPORARY OPERATION OPERATION AMBIENT TEMPERATURE Figure 2 Page 67 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems Nort
157. ssion of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide Spec No 589200300 Model XP4890 LIST OF PARTS Note This stocklist may not show every component contained in each List Number Note See also Field Replaceable Components List Number 528171 528229 528242 528259 528277 528171 528229 528242 528262 528277 528171 528229 528242 528260 528277 128824 528171 528229 528242 528261 528277 128824 534950 535009 535280 534950 128824 535280 536650 528229 536647 534749 534621 536650 528229 536647 534749 534621 536650 528229 536637 536638 534621 128824 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 2 1 1 2 2 1 1 1 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited Part Description Number Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar w o LVD 2U ISD Assembly cable distribution 2U ISD Assembly shelf 2U ISD Shunt DC 175A 25 mV Kit Mounting 2U ISD Busbar link 2U ISD Assembly cable distributi
158. staller s connections are made through the front See Physical Size Information for dimensions Restrictions Shelf accommodates max two 2 PCUs when List 47 is included Ordering Notes N O 5 co Order one 1 List 32 MCA Order PCUS per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order one 1 List 47 120VAC or 48 240VAC per shelf as required for voltage and cord length Note List 47 120VAC line cords are restricted to powering one 1 PCU each Also available are List 40 and 41 If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required For bullet nose distribution positions order circuit breakers as required per Table 5 For bullet nose distribution positions order fuses as required per Table 6 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug one hole 1 4 bolt clearance as required for each bullet nose distribution position per Table 2 10 For GMT alarm type fuse distribution positions order fuses as required per Table 7 11 Order Battery connectors as required per Battery Wire Sizes and Connectors List 11 12 13 and 14 Power and Distribution Shelves in the ACCESSORY I
159. strictions Not a direct replacement for earlier versions of List 4 Earlier versions of List 4 provided a single AC feed To replace a single feed version of List 4 order List 24 Ordering Notes 1 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required 3 Order Ringing Generators per List 72 as required If AC line cords are required order two 2 List 40 120VAC or two 2 List 41 208 240VAC per List 4 Power Shelf 5 If battery charge temperature compensation is required order a Battery Temperature Probe as required order per List 90 For multiple probes order One 1 List 92 TXM and List 91 probes as required 6 For bullet nose distribution positions order circuit breakers as required per Table 5 7 For bullet nose distribution positions order fuses as required per Table 6 8 Order one 1 Part No 117201 fuseholder per fuse ordered in 7 above 9 Order one 1 Load lug one hole 1 4 bolt clearance hole and one 1 Load Return lug two hole 1 4 bolt clearance holes on 5 8 centers as required for each bullet nose distribution position per Table 2 Page 14 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North Ame
160. the lowest capacity Caution A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty mounting position between it and any other overcurrent protective device Caution The maximum size circuit breaker or fuse used in ambient temperatures above 50 ambient SHALL BE 40 amperes Provides ten 10 mounting positions for GMT type distribution fuses 30A max total 1 15A fuses Provides one 1 load shunt total distribution current one 1 battery shunt and Low Voltage Load Disconnect Provides mounting positions for one 1 MCA and up to three 3 PCUs Provides two 2 AC input circuits via front access terminal block connections Conduit openings are provided on side panel in front of mounting angle Included are two 2 control bus termination plugs All control bus ports in the system must be filled with either a cable or a termination plug Mounts in a standard 23 relay rack Restrictions Not a direct replacement for earlier versions of List 3 Earlier versions of List 3 provided a single AC feed To replace a single feed version of List 3 order List 23 Ordering Notes o OD 5 Order one 1 List 32 MCA Order PCUs per List 53 55 or 56 as required Order Ringing Generators per List 72 as required If AC line cords are required order two 2 List 40 120VAC or two 2 List 41 208 240 VAO per List Power Shelf If battery charge temperature compensation is
161. tion outputs Local and external fuse alarm circuits are provided Designed to mount on a wall or relay rack rail Includes six dummy fuses and six fuse safety covers Distribution fuses are not included and must be ordered separately See Physical Size Information for Ringing Distribution Module dimensions Ringing Input 67 5 to 105 VAC RMS 100 VA max 20 25 30 Hz Ringing Output Six outputs each fused at 2A max See Ringing Distribution Module Installation and Operating Instructions Section 5991 for complete specifications Restrictions Maximum recommended distribution fuse size is 2A Ordering Notes 1 Order ringing distribution fuses as required from Table 7 AP6C57EA EB Ring amp Distribution Module Features When used with List 11 12 13 or 14 this module is designed to supply a filtered and regulated 48 VDC source and a continuous 20 Hz ringing supply source to imbedded subscriber loop carrier telecommunication systems such as SLC 96 or SLC Series 5 requiring up to 45 A of load capacity Designed to mount in a 23 relay rack the module is one rack unit high with 5 front projection Includes two 2 ringers with automatic transfer capability N 1 redundancy Provides 35 DC distribution fuse positions configured in five groups of seven feeding five channel banks Includes 35 dummy fuses Connectorized cables are available for SLC 96 or SLC Series 5 applic
162. tions 0 25 to 15 GMT Alarm Type Fuses Screw clamp type terminals Includes 6 dummy fuses equipped with safety fuse covers Restrictions When factory ordered assembly will be installed in the two bottom most bullet nose positions unless otherwise specified Maximum size of wire to be connected to a single fuse position is 14 AWG Fuses are not included Ordering Notes 1 For List 1 2 3 4 21 22 23 or 24 order Part No 529034 Provides one Part No 528958 alarm fuse distribution assembly one Part No 529033 ground return link and hardware 2 Order fuses as required per Table 7 nun Mounting Position for GMT Assembly When Factory Installed Page 45 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 Alarm Type Fuses Note When used for power distribution load should not exceed 80 of device rating except 10 and 15 amp fuses for which load should not exceed 70 of device rating
163. ttt C F LO 1 ALARM 8 NOW AT tttC F TEMPERATURE PROBE ALARM LIMIT ttt C F LO 2 ALARM 8 NOW AT tit C F TEMPERATURE PROBE NO SIGNAL 1 GO TO MAIN ALARM MENU 2 GO BACK TO MENU TREE BEGINNING Page 78 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited System Application Guide Spec No 589200300 Model XP4890 SAG589200300 Issue AM September 21 2009 From Sheet 2 FUNCTION MENU cont d on next page VIEW THE SYSTEM oa MEASUREMENTS FLOAT IS ACTIVE CHANGE MODE or SET FLOAT MODE or EQUALIZE IS ACTIVE hhh mm ss or EQUALIZE IS ACTIVE CHANGE MODE or SET EQUALIZE MODE 98 or BATTERY TEST ACTIVE hhh mm ss or BATTERY TEST ACTIVE CHANGE MODE or SET BATTERY TEST MODE or THE EQUALIZE INPUT IS ACTIVE or THERMAL RUNAWAY IS ACTIVE VIEW THE SYSTEM 99 INVENTORY To Sheet 6 SHEET 4 MEASUREMENT MENU SYSTEM OUTPUT SENSE vv vvV REM or SYSTEM OUTPUT SENSE vv vvV INT TOTAL LOAD CURRENT LOAD CURRENT MENU PANEL S LOAD aaaaaA GO TO MEASUREMENT MENU GO BACK TO MENU TREE BEGINNING PCU CURRENT MENU
164. unted from top to bottom starting with the highest capacity and working to the lowest capacity 3 For lug and wire size selection refer to Table 2 BULLET NOSE TYPE CIRCUIT BREAKER PART NUMBERS Rating Provides alarm for this trip condition Rating Provides alarm for this trip condition LJ ON M ON NL Black Handle White Handle Black Handle White Handle 1 101596 102272 40 101605 102281 3 101597 102273 45 121997 121998 5 101598 102274 50 101606 102282 10 101599 102275 60 101607 102283 15 101600 102276 70 101608 102284 20 101601 102277 75 101609 102285 25 101602 102278 80 121995 121996 30 101603 102279 100 101610 102286 35 101604 102280 Unless otherwise specified circuit breakers shall be mounted from top to bottom starting with the highest capacity and working to the lowest capacity Table 5 Page 43 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 TPS TLS Type Fuses A single fuseholder provides for installation of
165. upply the load main generator with the other becoming the standby generator If a failure occurs in the main generator the ringing load will automatically transfer to the standby generator A failed ringing generator can be replaced without interrupting ringing power to the load Controlled and monitored by system s MCA MCA supports up to 4 List 72 Restrictions Provides bulk ringing output only Distribution must be external MCA interfaces with a maximum of 4 List 72s Outputs from multiple List 72s cannot be paralleled MCA version 4 0 or newer required for full compatibility Ordering Notes 1 Order one 1 List 72 for up to 50 VA of redundant bulk ringing power 2 For external ringing distribution order Part No 528608 Ringing Distribution Module List 73 Replacement Ringing Generator List of Parts Features Field replacement for one of the two Part No 487112100 Ringing Generators that are provided with List 72 Ordering Notes 1 Order as a replacement part only Two Ringing Generators are included with each List 72 ordered Page 31 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200
166. ur 4 battery midpoint monitoring inputs All functions are configured and controlled by the system MCA External mounting Includes one 1 2 ft MCA control bus cable P N 524410 and one 1 control bus termination plug P N 524653 See Physical Size Information for Load Shed Card dimensions See Load Shed Card Installation and Operating Instructions Section 5985 for complete specifications Restrictions Load shed contactors are not included A system battery shunt is required for timed Load Shed Page 47 of 105 This document is property of Emerson Network Power Energy Systems North America Inc and contains confidential and proprietary information owned by Emerson Network Power Energy Systems North America Inc Any copying use or disclosure of it without the written permission of Emerson Network Power Energy Systems North America Inc is strictly prohibited SAG589200300 System Application Guide Issue AM September 21 2009 Spec No 589200300 Model XP4890 MCA version 3 0 or newer is required Maximum number of Load Shed Cards supported by MCA is four 4 Maximum combined MCA control bus cable length must not exceed 125 feet Ordering Notes 1 Where MCA control bus cable lengths other than the furnished 2 ft cable are required order per List 81 Ringing Distribution Module Part No 528608 Features Designed to accept a bulk ringing input signal and provide six 6 fused ringing distribu
167. urrent limit setting During normal operation the battery is not required to furnish load current and remains in a fully charged condition The float voltage setting can be checked and or adjusted without removing a PCU or affecting the load One adjustment changes the output of all PCUs Note If the current demanded by the load exceeds the current limit setting of the system the battery is required to furnish the difference in load current and begins discharging Note Ifthe system is used with a battery temperature probe the MCA automatically adjusts system output This ensures proper voltage to the battery as battery ambient temperature fluctuates 2 3 8 Equalize Charging Output Mode A This mode of operation is used if higher output voltage is required for equalizing the charge on all battery cells of a conventional flooded cell battery or for recharging the battery following a commercial power failure The Equalize voltage setting can be checked and or adjusted without removing a PCU or affecting the load One adjustment changes the output of all PCUs Note If the system is used with a battery temperature probe equalize mode of operation is not used B There are three methods of placing the system from the Float mode to the Equalize mode 1 Method 1 Manual Equalize A user manually places the system into the Equalize mode via the MCA interface A user must manually return the system to the Float mode via the MCA interf

Download Pdf Manuals

image

Related Search

Related Contents

M155 DECT Messenger  télécharger - Pensées de Psychiatrie  Programme annoncé et congrès OFF  Des rythmes scolaires  Contents - InnoSys Inc.  8 - Newegg.com  GENERADOR DE FUNCIONES Modelo 9205  LES RENCONTRES DE L`EMPLOI  Lincoln Electric Invertec STT II User's Manual  Listado de Servicio Técnico Autorizado Manual de Instrucciones, y  