1. 75 28 hours without with display back light switched on At least 20 hours for a complete charge Settable auto off after 5 10 20 30 minutes standstill or no auto off active Settable on off or automatic on during weighing display gt 0 0 kg 2400 9600 Bd settable 8 data bits 1 stop bit no parity CR and LF fixed string 13 bytes decimal dot and a kg sign included 9 pole male D connector 4 transmission modes Tel 31 36 522 20 30 Fax 31 36 522 20 60 Website www weegtechniek nl Email info weegtechniek nl pag 3 oe ae eae aa holland b v Manual SA 250 Display keys and display symbols Front panel PCG C SA 250 Manual 27 03 07 Max 150 kg Min 1 kg e 50 g Keys Indications Switch on scale Led orange yellow battery is charging LADEN Led yellow green charging completed Switch off scale Weight is above the settled up limit QO EB Weight is in between the up and down limit Switch on parts counting function Weight is below the settled down limit Indication of Max 150 kg maximum scale capacity Set zero of the gross weight value Min 1 kg legal minimum weighing range range en 2 of the scale capacity e 50g value scale divisions e 2 Sell Tare set zero over the complete Display symbols scale capacity 0 Reading is exact zero within 0 2 scale division Hi Lo function input weight limits ib ad Reading has achieved a complete stand
2. With key O the available choices are shown With key the selected function may be entered followed by automatic o the next menu line Automatic switch off WEEGTECHNIEK HOLLAND B V Patroonsweg 23 27 3892 DA ZEEWOLDE The Netherlands The Auto off function switches off the scale automatically after minutes standstill not in programming modes This saves the battery s capacity 0 auto off switched 1 5 minutes 2 10 minutes 3 20 minutes 4 30 minutes With key Q the available time delays are shown With key e the selected value may be entered followed by automatic ot stepping to the next menu line Website www weegtechniek nl Tel 31 36 522 20 30 Email info weegtechniek nl Fax 31 36 522 20 60 pag 9 p Mecstechnick Manual SA 250 holland b v PCG C SA 250 Manual 27 03 07 Back light display The back lightning of the display may be selected as 0 always off 1 always on 2 automatically switching on if weight gt 0 0 kg With key LA the available choices are shown With key E the selected function may be entered followed by automatic stepping to the next menu line Initial zero setting After switching on the scale will automatically l a r A a a Ll 0 set zero based upon the last time the scale was set to zero with set zero based upon the actual situation after standstill l With key Q the available choices are shown With key E the selected function ma
3. 3892 DA ZEEWOLDE The Netherlands gt qfeestechnick holland b v pag 5 Manual SA 250 PCG C SA 250 Manual 27 03 07 in weighing mode only Add the article with the correct weight on the platform and press key 4 The reading sets zero The symbol at NET shows up Replace the article for the item to be checked and read the deviation in or This tare may be deleted by pressing key with an empty platform 1 Count by hand a number of articles 10 20 50 100 of 200 pieces The less weight of an article the more pieces have to be used in order to achieve an accurate counting 2 Take care of an accurate zero reading 0 and standstill mua Add the pre counted articles in one operation upon the platform 3 Press keys p The available quantities show up on the display as running numbers Press key r3 again at the moment the correct quantity appears on the display 4 Now the scale counts the number of articles the display shows the number of articles The arrow at indicates that the parts counting mode is in operation 5 With key F may be switched i e from the counting mode to the weighing mode and back The weight of the article is not deleted by this If an other article has to be counted go back to the weighing mode with key Fr and start at point 1 again Note in this program negative counting after taring is not possible in weighing mode only if selected in the USER mode The Hi
4. Manual SATEX SA 250 Platform Scales certified for trade E We e g t e C h Nn e k Aga read Holland holland b v uei pene Email info weegtechniek nl Website www weegtechniek nl 4 pag 0 bonne Manual SA 250 holland b v PCG C SA 250 Manual 27 03 07 tlc t E 1 Application Weight and Measures Certification 1 DIOL NT 1 AIM CHIANG Qiassusc tonscinestestatidda aive Pes bun De rau usd a aiei 1 ICM 2 Technical SpecificationS ccccccceeceeeeeeeesseeeseeeeesaneneaes 2 Display keys and display symbols sussussse 3 SWN OM ME E ae onaes 4 Era O E 4 WR m O9 4 NGC WC OMI eraran usum Me ueber xi epa aH gutes PI OI PIE 5 Counting PaO nisreen E E Ea RUSQUUD PT RS 5 Hi Lo check WeIQNING ccccce cece eeeceeeseeeeeeeeeeeseeesaneeeaes 5 Hold TUNCTION ccc cece eee c cece cece e ee enna eee eeaeeeeeeaeeeeesaeeeees 6 Printing 7 sending Cal eusadananssa xxu eu ti dant tco Ran Vade Edd co ac 7 USER MODE Automatic zero zero track esses 8 Automatic switch off auto Off ccc cece eee ce ee enna eee eeaees 8 Back light display cccececeee cee e eects ceases eeeeeeeeeaeeeeneeeaees 9 Janizilva iox nilne peer 9 DISDIAY SDODO assit nul ritu data uox 2 8d enprex Ew HpUREM Van RE S e ERU a URS 9 Printer RS 232 data output esses 10 Disable dou
5. but zero setting is not possible since the 2i he weight signal is higher or lower as 10 of the scale capacity Remove the load on the weigh platform Check cable and connector Execute a new one point adjustment procedure until point 2 zero setting The scale refuses zero setting 30 nn dc The weight signal is outside the zero setting range and 296 scale capacity C Li Z2 Tare function will operate correctly Switch the scale off and on again so a new zero 4 and 1096 scale capacity may be settled Heading is gross negative Set zero and set tare not possible The scale has been switched on with a load on the platform and has set zero with this load Thereafter the load has been removed and now the reading is gross negative Switch the scale off and on again with an empty platform The load on the platform is higher as the maximum scale capacity overload Remove the load from the weigh platform Check cable and connector The loadcell could be damaged The weight signal is far too negative Check the correct position of the weigh platform and clean the interior of the platform Check for damage of the cable and connector The loadcell could be damaged Execute a new adjustment procedure i I DHL I Power supply excitation is too low battery is empty Lo Dncrc Recharge the battery The Hi Lo function cannot be selected with key F F No weight values has been entered in the Hi Lo mode Enter upper and down limit we
6. display reading will return to the weighing mode A check of the present weight values only may be done by simply pressing key three times Hold mode in weighing mode only and the function has to be selected in CAL mode This Lock up function is permanently switched off at legal stamped scales The weight value of a weighing may be locked up temporarily ur 4 i This may be done in two different way s setting in CAL menu a kg F1 The weight value will be locked up as soon as the reading comes to a NET exact standstill until the scale display returns to zero and comes to a standstill at zero F2 The weight value will be locked up as soon as a standstill within 1 2 or 3 scale divisions is determined However if the real weight value changes for at least 1 2 or 3 scale divisions the lock up will be set free On the condition that the Hold function has been selected in the Calibration Menu the function may be switched on and off by pressing key F The display shows in the left corner above which of the hold functions is in operation with the symbols F1 or F2 WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 431 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 431 36 522 20 60 3892 DA ZEEWOLDE The Netherlands pag 7 betonen Manual SA 250 holland b v Printing sending data Four functions of the procedure of data transmission may be selected in the User Menu PCG C SA
7. 250 Manual 27 03 07 0 Switched off 1 1x printing or transmission to a PC after pressing key Transmission is executed if 0 a the reading has standstill at pressing the key ma symbol is on LLL Ill kg the reading has had a standstill at O after the last transmission the reading is gt 0 b ad After pressing key a short beep sounds to confirm the transmission A longer beep indicates that no transmission will be executed since there is no standstill of the weight value or the reading has not been stable at zero before not active in the Hi Lo mode 2 automatic 1 x printing or transmission after each weighing Transmission is executed if the reading has come to a standstill a4 symbol is on the reading has had a standstill at O after the last transmission the reading is gt 0 the reading is in the weighing mode 3 continuous transmission Print of weight In the weighing mode only Transmission speed is about 10 Hz Attention gross negative values are transmitted too 30 240 kg At loads above the maximum scale capacity the transmission stops 28 750 kg In this mode the selected extra empty printing lines before and after the actual 7 890 kg data are not transmitted Printing examples Print of counting weighing HR version G gross N net G 20196 k pieds 3046s o QTY PCS quantity pieces T 0 000 kg PCW piece weight in grams OY 403 PCs PCW 50 06
8. Lo function offers the feature to do a very quick check on the weight of series of articles or to fill constant quantities within the settable weight ranges Two weight values may be entered These values will be used as upper and lower limits indicating that a measured weight value is HI 2 weight too high OK correct weight LO weight too low The three LED s left next to the display indicate the weighing result in red green or yellow Long or short beep sounds may be connected to the HI OK and LO functions via the User Mode page 11 Setting of the weight values is done with key F see next page On the condition that weight values have been entered pressing key starts and stops the HI LO function as well as the counting function Website www weegtechniek nl Tel 31 36 522 20 30 Email info weegtechniek nl Fax 31 36 522 20 60 pag 6 gt qeestechnick Manual SA 250 holland b v Hi Lo weighing continued Setting the weight limits PCG C SA 250 Manual 27 03 07 HI 1 Press key us The Hi Lo symbol and the red LED at HI show up The present value of the upper limit is shown The last figure is flashing and may be changed now with the cursor key Oj With key Q the next figure may be turned on and so on LO 2 Press key again The yellow LED at Lo will light up The present value of the upper limit is shown Continue procedure as with the entering of the upper limit value 3 By pressing key again
9. V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands Weegtechniek holland b v EN Ed ca Cc Cl Co Co C3 RN c3 E c3 L3 L3 Uu d P2 co ALN c2 ca ca a a Ex Eu Uu me N FRR C EN c3 c3 ca C23A Ut ES c3 ES Cl co ES c3 Ty WEEGTECHNIEK HOLLAND B V Patroonsweg 23 27 3892 DA ZEEWOLDE The Netherlands pag 16 Manual SA 250 PCG C SA 250 Manual 27 03 07 12 Add weights for the 3 point of adjustment upon the scale This is not necessarily the max weighing capacity 13 Press key to enter the measured weight signal 14 Enter the value of this weight with the keys increase and QO switch left The symbol F3 indicates this second point of adjustment 15 Press key to enter the value of the weight 16 The display now asks for the value of the maximum scale capacity The display shows SP 2 the figure at the right flashes and may be edited now with key s With key O the next figure is made editable and so on During normal operation of the scale the weight reading will switch off and show overload at loadings above this weight value 9 divisions 17 Press key to enter the value of the maximum weighing capacity The display shows CAL during the entering procedure The adjustment procedure will now be finished and the scale will
10. automatically return to the normal weighing mode 8 Remove the weight from the weigh platform 19 Switch the scale off and on again All keys will be accessible now The scale is ready to be used Website www weegtechniek nl Tel 31 36 522 20 30 Email info weegtechniek nl Fax 31 36 522 20 60 gt e estechniek holland b v RS 232 output Data communication Table1 Byte Format start Stop Table 2 Weight transmission only 1 string format 13 bytes m t a 2 4 5 6 7 e o to r ria k Table 3 Weight and counting transmission 5 strings format 14 16 bytes me i 2 3 4 s 6 ve o to rta 13 t4 15 t6 Gja x x x b xx x a k o por Nja x x x b x x x a k opcmr Tja x x x b x x x a k o jor T Yja x xixix x x a P o s entr X Pin configuration RS 232 connector inside indicator solder side Pin configuration RS 232 cable connector solder side pag 17 Manual SA 250 PCG C SA 250 Manual 27 03 07 Baud rate 2400 9600 selectable Parity none Data bits 8 Codes CR and LF a either a blank or a minus sign X blanks and or weight figures b decimal dot C blank k and g weight unit kilo gram In weight figures with 2 or 1 figure behind the decimal the decimal dot is in position 6 or 7 Weight figures without a decimal are transmitted without a decimal dot too Gross weight Net weight are weight QTY Quantity of counted pieces PCS Weight of one sing
11. right flashes and may be edited now with key With key FY the next figure is made editable and so on 6 Key in the complete weight value of the maximum scale capacity j L CAPACITY During normal operation of the scale the weight reading will switch off and show overload at loadings above this weight value 9 divisions 7 Press key t to enter the value of the maximum weighing capacity The display shows CAL during the entering procedure The adjustment procedure will now be finished and the scale will mame automatically return to the normal weighing mode 3 LI LI LI LI 8 Remove the weight from the weigh platform mre 9 Switch the scale off and on again All keys will be accessible now o7 LLL LN kg The scale is ready to be used WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 Co co N UO 2 N m m O m U m 3 D ed E D D C o pag 15 Weegtechniek Manual SA 250 holland b v PCG C SA 250 Manual 27 03 07 Multi points adjustment Procedure with 3 reference weights Press key to step to the next menu line zero adjustment CO The actual zero value can be read now in points of the A D converter ZERO VALUE The value should be in between 5 000 and 50 000 If this is not so adjust with switch 1 on the main print board Uti M Uti Uo 2 Setthe readin
12. scales is under EC rules not accessible The breaking of the legal seals only makes this access possible Breaking the seals of housing and platform terminates the warranty besides that it is a legal crime that may cause severe financial fines Scale divisions 18 different scale divisions d are selectable 0 001 0 1 0 010 J nnnl i 0 002 0 2 0 020 P uuu 0 005 0 5 0 050 0 01 1 10 0 02 2 20 0 05 5 50 E ar JZ 2 J With key the available choices are shown With key ius the selected choice may be entered followed by automatic stepping to the next menu line If the scale has to be adjusted only skip this function by pressing key WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 431 36 522 20 60 3892 DA ZEEWOLDE The Netherlands pag 13 b onek Manual SA 250 holland b v Hold function Lock up function is always disabled at legal stamped scales PCG C SA 250 Manual 27 03 07 The lock up function has 3 programs available 0 switched off 1 The weight value will be locked up as soon as the reading comes to a exact standstill until the scale display returns to zero and comes to l a standstill at zero LOC I 2 he weight value will be locked up as soon as a standstill within 1 2 or 3 scale divisions is determined However if the real weight value changes for at least 1 2 or 3 scale divisions the lock up will be set free L
13. 60 3892 DA ZEEWOLDE The Netherlands pag 14 Weegtechniek Manual SA 250 holland b v PCG C SA 250 Manual 27 03 07 One point adiustment Procedure with one reference weight 1 Press key to step to the next menu line zero adjustment The actual zero value can be read now in points of the A D converter 493 l5 msc The value should be in between 5 000 and 50 000 If this is not so adjust with switch 1 on the main print board 2 Setthe reading to zero with key If only the zero has to be adjusted the procedure may be terminated from here by pressing key S Putan accurate weight value free to choose in the middle of the weigh du4548 WEIGHT VALUE platform The display reading should be now in between 50 000 and 250 000 points If this number is higher or lower an accurate adjustment is not to possible 4 Press key to enter the measured weight signal The display now asks for the value of the weight that has been put upon the scale The display shows SP 1 the figure at the right flashes and may be edited now with key With key Q the next figure is made editable and so on Co Co Co Co SP 1 NU m cu OO T 5 Key in the complete weight value and enter with key The display will show CAL during the entering procedure and will step forward to the next menu line S2 m mum n The display now asks for the value of the maximum scale capacity LL LILILI The display shows SP2 the figure at the
14. 99 g The empty spaces above and below the printed lines may be selected max 9 empty lines in the User Mode G 5 041 kg N 4 344 kg T 0 697 kg QTY 856 PCS PCW 5 07199 g WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands b qecsicchnick holland b v The hatched frames show the default settings pag 8 Manual SA 250 PCG C SA 250 Manual 27 03 07 USER mode how to operate The User Mode is selected by pressing key F continuously and then starting the scale with key on As soon as the display shows CAL release the F key After operating key in one of the menu lines the present values of that line will be entered followed by automatic stepping to the next line After this at each line position in the menu the User Mode may be shut down by pressing key memorizing all the data that has been entered via key Ia Press key on to to the first and the next menu lines With key O the available settings of each line may be selected The User mode is always accessible for the user and may be edited MENU X USER mode Automatic Zero Auto 0 keeps the reading with an empty platform on zero ho u Yo division stepping t The automatic zero setting may be switched off or selected to be in operation around or 2 scale division from the gross zero weight value
15. CIC L If program 2 is selected this will offer the opportunity to select the number of Y divisions that will be used to determine the rate of motion that will start up and hold on the locking of the weight reading within 1 scale division within 2 scale divisions within 3 scale divisions With key the available choices are shown hm With key the selected choice may be entered followed by automatic stepping to the next menu line Choice of the weight adjusting procedures There are 2 procedures available to adjust the weight reading single point adjustment with one free to choose weight value Co I multi points adjustment with 3 free to choose weight values with this method a not linearity of the scale may be compensated With key the selected choice may be entered followed by automatic stepping to the next menu line CAL according to the selected choice this will be the one point or multi points adjustment procedure With key the required program may be selected With the one point procedure the best results are achieved by choosing a reference weight value of about 2 3 of the scale capacity With the multi points procedure the best results are achieved by choosing reference weight values of about 1 6 2 3 and 3 8 of the scale capacity WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20
16. atroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands Level indicator gt 7 eestechniek holland b v Start up RS connector Mains adaptor and x i Si l 333 Tumabe f console Indicator 4t Pole Z Weigh platform Pole foot w f platform cable connector 1 pag 2 Manual SA 250 PCG C SA 250 Manual 27 03 07 Carefully unpack the scale Check the presence of weigh platform with digital indicator stainless steel pole with locking bolts and bolt spanner mains adaptor in carton box English user manual gt Fix indicator upon the pole and the pole into the foot lockup bolts gt Put the scale in level position with the level indicator and the 4 leveling feet gt Connect the platform cable to the indicator connect mains adapter and press the ON switch with an empty weigh platform The scale automatically sets zero and is ready for use now gt The built in battery allows the scale to work for maximum 75 hours without connection to mains supply Due to differences in temperature it may last until 10 minutes after switching on before the reading of the weight is completely accurate Place the articles to be weighed carefully on the weigh platform Prevent for bumping against and overloading of the weighing platform The loadcell down under it may be damaged seriously Check if necessary the accuracy with an accurat
17. ble printing cccccccee cee eeeeeeeeeeaeeeeeeeaeeeaes 10 Extra ING Tecde REED RTT 10 Baud ANS ERPRTERTT 11 Hi Lo setting on off DECDS ccc eee esceeeeeeeseeeaeeeaes 11 CALIBRATION MODE DIVISIONS cout caceantbacancesee E E nv EE ARENDE 12 LOCK UD weight Valli amp essus piace x ed ir tiskin Rr Dac eo apri a 13 Choice calibration ProC Cure cc cece eee eeeeeaeeeaeeeeeaeeeaes 13 One Point calibration cccccceeeececeee cece ee eeeeeeeeeneaeenanas 14 Multi Points calibration ssseeeeeennnnmmmmnI 15 16 RS output Data communication sseesseeeeeeeeee 17 Loadcell connection sseeeesssseeeenn 17 Malfunctions and error codes sseseseeeeee 18 WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 431 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands pag 1 m Pr Manual SA 250 holland b v PCG C SA 250 Manual 27 03 07 Thank you for purchasing this SATEX precision balance This scale is equipped with reliable technology and has user friendly operational software You will use it many times and it will prove itself to be an easy speedy and accurate tool If any questions raise that are not described in this manual please address yourselves to your SATEX supplier have a look at our website www satex
18. d if the weight is correct At display reading 0 0 kg the beeps will be switched off 0 no beeps 1 shortbeeps be be be be 2 long beeps beee beee beee With key O the available choices are shown With key E the selected choice may be entered followed by automatic stepping to the next menu line Website www weegtechniek nl Tel 31 36 522 20 30 Email info weegtechniek nl Fax 431 36 522 20 60 pag 12 pd iecstechnick en aa holland b v PCG C SA 250 Manual 27 03 07 CALIBRATION mode how to operate The User Mode is selected by pressing key Q continuously and then starting the scale with key on l As soon as the display shows CAL release the Q key The hatched frames Press key Qo to step to the first and the next menu lines a Pee After operating key in one of the menu lines the present values of that line will be entered followed by automatic stepping to the next line Use key to edit a parameter in a menu line The menu may be closed with key f5 all edited data will be memorized that have been entered with key uio However once an weight adjusting procedure has been started it has to be completed to its full extend If this is not done the weighing results will be incorrect and not reliable The User mode is not accessible in legal stamped scales MENU CALIBRATON mode not accessible in legal stamped scales and on request Attention The calibration mode in legal stamped
19. e calibration weight Using the calibration procedure page 13 the scale may be re adjusted Stamped scales are sealed to prevent for illegal adjustments At first start up the built in battery may be not completely loaded Re load the battery by leaving the scale in OFF position for at least 16 hours with a connected mains adaptor Technical specifications Weighing capacities Accuracy Environmental Construction Excitation Operation on battery Battery charging time Automatic switch off Display back light RS 232 data communication WEEGTECHNIEK HOLLAND B V Patroonsweg 23 27 3892 DA ZEEWOLDE The Netherlands in operation 0 40 C Capacity and division are user settable via the software Legal trade version has 3000 divisions the High Resolution HR version has up to 15000 scale divisions Fulfils the European Weight and Measures regulations EN 45501 for new weighing scales at a load of O 500 divisions deviation lt V scale division 500 2000 divisions deviation 1 scale division 2000 3000 divisions deviation lt 11 2 scale division The HH version has a deviation of max 2 divisions in stock 10 55 C max 85 RH Stainless steel platform ABS housing of indicator coated aluminum 34 SA or steel 46 66 SA weigh frames stainless steel pole with cast aluminum foot Mains adaptor 230 VAC 50 Hz 60 mA output 9 VDC 500 mA built in rechargeable battery and charger
20. g to zero with key If only the zero has to be adjusted the procedure may be terminated from here by pressing key E Press key Qo to step to the next menu line 1 point of adjustment After a short LN 1 the display reading sets zero 4 Putan accurate weight value free to choose on the weigh platform Previously used calibration weight value may be shown now LA PCS J c2 5 Cc C3 aL Us A possible deviation from this previous adjustment now can be read 5 Press key iso to enter the measured weight signal T ru L Liou 6 Enter the value of this weight with the keys increase and F switch left The symbol F1 indicates this first point of adjustment rn it 7 Press key to enter the value of the weight After a short LN 2 the program steps to the 2 point of adjustment The adjusted value of the present load may be read now Lr Ae C3 ca c d C C23A 8 Add weights for the 2 point of adjustment upon the scale I200T L LLLILITI 9 Press key iso to enter the measured weight signal lt ri nmi 10 Enter the value of this weight with the keys increase and CF switch left LI LI LI LJ The symbol F2 indicates this second point of adjustment 2 JOIN Pou LILI 11 Press key uo to enter the value of the weight After a short LN 3 the program steps to the 3 point of adjustment e a V m Arni The adjusted value of the present load may be read now L LLLILILI WEEGTECHNIEK HOLLAND B
21. ight values with the key Hi Lo The Hi Lo function is disabled in the USER mode The Lock up function cannot be selected with key F Fo The Lock up function is disabled in the Calibration mode No data transmission or printing follows after operating the printer key The transmission function is disabled in the USER mode Scale reading is at zero Scale reading has not been on zero with standstill after the last transmission WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands
22. le piece The position of the decimal dot is here dependent on the presentation of the figure itself weight unit gram AzQ Q Connector DB 09 Male Pin 1 3 4 6 7 8 9 NC Pin 2 TXD Pin 5 GND Loadcell connection Connector DB 09 Female Loadcell cable D connector Cable internal Print colors Me on indicator O indicator Excitation Excitation pint pint ENSE back pna Sgmi rd pns bak S These are the standard wire colors Other colors may be applied In that case the loadcell has to be checked by measuring the resistances per wire group Exc en 420 Q Sense and 420 Q Signal and WEEGTECHNIEK HOLLAND B V Patroonsweg 23 27 Email 3892 DA ZEEWOLDE The Netherlands Pin configuration loadcell connector solder side inside indicator Pin configuration loadcell cable connector solder side 5 350 Q Website www weegtechniek nl Tel 31 36 522 20 30 info weegtechniek nl Fax 31 36 522 20 60 pag 18 Weegtechniek holland b v Manual SA 250 PCG C SA 250 Manual 27 03 07 Malfunctions and error codes i Lod stays on display At switching on the weight signal is too low Lo c Check the correct position of the weigh platform and possible damage of the connecting cable and connector The loadcell could be damaged Execute a new one point adjustment procedure until the point 2 zero setting The scale has been switched on
23. nl or send your questions per email to info satex nl Application Weight and Measures certified The SA 250 platform scale balance is designed for accurate and legal weighing for counting of articles and for check weighing and filling with settable weight setpoints with LED indicators in the front panel The scale is designed for use in dry inside conditions The weigh platform is equipped with an IP 65 water and dust tight HBM off centre loadcell Take care of a stable position of the scale Place it in accurate level position with the help of the 4 leveling feet and the level indicator down below the pole Important all 4 of the feet should carry the scale equally The CE OIML R76 1992 class III Certificate of this scale is valid in all European countries It is permitted to use the scale if stamped individually for weighing for trade purposes However there is no difference between the accuracy of a stamped or not stamped scale Even if the scale has been purchased without the legal stamping it may be stamped later on if the scale still is in good condition Safety Please read this manual thoroughly before start using the scale The supplier does not accept any responsibility if the guidelines of this manual are not observed Before any work is done on the scale power connections from the mains adaptor and the internal battery should be interrupted Warranty is void if the scale is opened anyhow Breaking of the seal of a stam
24. ped scale is a criminal act and causes the complete disapproval of the scale The instrument fulfils the requirements laid down in the EG regulations 89 336 EWG and 73 23 EWG for electromagnetic compatibility and the Council Directive 90 384 EEC for not automatic weighing machines Exceeding of the maximum values laid down in these regulations must be avoided Electrostatic discharges may cause fatal damage to the scale and should be avoided at all times l e a proper earth connection of the scale and the place of erection is required in such cases The mains adaptor has no special protection against humidity and water and should not come into contact with it In case this has happened or the adaptor shows any external damage the adaptor should not be used any longer The built in lead battery should if it has to be replaced be disposed off as small chemical waste not to be added to normal waste Maintenance Except from regular cleaning with a slightly humid cloth and a not aggressive detergent further maintenance is not required The stainless steel platform plate may be removed to clean the inside of the weigh platform However it makes sense to check the scale s weighing accuracy with regular intervals using accurate calibration weights otamped scales are sealed but a not stamped scale may be adjusted by the user itself using accurate Class M1 weights WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 P
25. ready to be used If the display with an empty weigh platform does not show a zero reading press key The zero setting range is limited up to and 2 of the scale capacity Outside this range zero setting will not be executed If more than 296 zero setting is required switch the scale off and on again The zero setting range is than and 10 Small deviations from zero lt 12 scale division are automatically compensated so the empty scale will always stay at zero reading This procedure is called zero tracking The addition of very small weights scale division starting from zero reading may cause faulty weight presentation caused by the zero tracking In that case the zero tracking may be switched off via the User Menu page 8 Tare taring is zero setting possible over the complete scale capacity Place empty container on the platform and tare to zero with key After standstill the weight reading sets zero The symbol at NET shows that a taring has been operated display reading now is the net weight Ze Taring may be repeated up to the maximum scale capacity The tare may be deleted by pressing key with an empty platform WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 431 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands Check weighing Hi Lo check weighing WEEGTECHNIEK HOLLAND B V Patroonsweg 23 27
26. stechniek holland b v Baud rate bbH Hi Lo settinq WEEGTECHNIEK HOLLAND B V Patroonsweg 23 27 3892 DA ZEEWOLDE The Netherlands pag 11 Manual SA 250 PCG C SA 250 Manual 27 03 07 Two Baud rates are selectable 9600 Bd and 2400 Bd With key QO the available choices are shown With key L the selected speed may be entered followed by automatic stepping to the next menu line On off De Hi Lo function may be switched on or off 0 off 1 on With key O the available choices are shown With key Ld the selected choice may be entered followed by automatic stepping to the next menu line Beeps at Hi Short or longer beeps may sound if the weight is above upper limit At display reading 0 0 kg the beeps will be switched off 0 no beeps 1 shortbeeps be be be be 2 long beeps beee beee beee With key QO the available choices are shown With key Ld the selected choice may be entered followed by automatic stepping to the next menu line Beeps at Lo Short or longer beeps may sound if the weight is below low limit At display reading 0 0 kg the beeps will be switched off 0 no beeps 1 shortbeeps be be be be 2 long beeps beee beee beee With key O the available choices are shown With key E the selected choice may be entered followed by automatic stepping to the next menu line Beeps at OK Short or longer beeps may soun
27. still if the function is selected only NET If the sign up here is on the reading is the Toggle from weighing weighing with net weight value a tare value has been subtracted lock up gt Hi Lo gt parts counting and back Cursor operation left move Scale is in parts counting mode Printing data transmission Hi Lo The Hi Lo function is in operation Cursor operation up move F1ofF2 The lock up function is in operation Operating a key causes a short beep sound as a confirmation If a selected function cannot be executed a longer beep sounds as a warning WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands pag 4 gt qfeestechnick Manual SA 250 holland b v Start up PCG C SA 250 Manual 27 03 07 At start up with the on key the display shows briefly Lod Loading During start up the display shows 3 x all the segments of the figures and the decimal dots running from left to right and the kg sign Next turn the display shows the program number PSP n1 After that the scale will automatically set zero as soon as the reading has come to an exact standstill Only after exact standstill the symbol Q is shown followed by the symbol 4 and the display reading will be zero After maximum 10 minutes warming up time the measuring system is stabilized and the scale is
28. tting the condition that a second printing is allowed only if the reading has been returned one time to O kg 1d This O value may be setted at and 1 2 or 5 scale divisions d around the actual zero At setting at 0 double printing data transmission is not disabled 2d With key 4 the available choices are shown r4 5d With key on the selected function may be entered followed by automatic LL ee D J stepping to the next menu line Extra empty lines Line Feeds For In order to place the printed lines on a printed label on the required hight max 9 empty lines may be inserted in front of the actual data lines fl The shown number corresponds with the number of empty lines line feeds G With key fa the available numbers are shown i i L L With key E the selected number may be entered followed by automatic stepping to the next menu line Extra empty lines Line Feeds After In order to create more space after the printed lines 9 empty lines may be inserted after the actual data lines The shown number corresponds with the number of empty lines line feeds With key Q the available numbers are shown With key on the selected number may be entered followed by automatic stepping to the next menu line WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 431 36 522 20 60 3892 DA ZEEWOLDE The Netherlands gt e
29. y be entered followed by automatic stepping to the next menu line Display speed The speed of refreshment of the display reading is settable Under unstable conditions a lower refreshment speed may give better readability of the weight values 0 standard 10 Hz 1 lowspeed 5 HZ 2 lowest speed 2 Hz With key QO the available choices are shown With key E the selected function may be entered followed by automatic stepping to the next menu line WEEGTECHNIEK HOLLAND B V Website www weegtechniek nl Tel 31 36 522 20 30 Patroonsweg 23 27 Email info weegtechniek nl Fax 31 36 522 20 60 3892 DA ZEEWOLDE The Netherlands pd rS holland b v Manual SA 250 Printer RS 232 data output PCG C SA 250 Manual 27 03 07 Four different functions of the RS 232 data output are available 0 switched off 1 1 x transmission after key operation at standstill Peo gd 2 automatic 1 x transmission each time the scales comes to a standstill after return to zero and standstill at zero and the display reading is not at zero continuous transmission with ca 10 Hz 3 Choices 2 and 3 are not available for the counting and lock up modes With key QO the available choices are shown With key E the selected function may be entered followed by automatic stepping to the next menu line Disable double printing added medio 2007 Twice printing of the same weighing could be undesirable and may be switched off disabled by se