1. or press the touch panel with too much force for it may cause irreparable damage Do not use GP in an environment where the surrounding temperature exceeds the specification range for it may damage the unit Please ensure that liquids or metal do not enter the GP unit for it may cause malfunc tion or a short Please avoid using the unit in areas where sudden large changes in temperature may occur These changes can cause condensation to form inside the unit possibly caus ing an accident To prevent from heat building up inside the GP please do not install GP where its ventilation holes may be blocked or where heat cannot escape Also please avoid using or storing the GP in an extremely hot place Do not operate the GP in areas with temperatures and humidity in express of those levels specified to prevent the GP s touch panel from becoming warped or bent Please avoid using or storing the GP under direct sunlight or in a dusty environment This unit is a delicate equipment so please avoid using or storing the GP unit in an environment where it can receive strong impact or vibration Please avoid using or storing GP where vaporized chemicals or chemicals can stick to it Do not use paint thinner or organic solvents to clean the GP unit or display Due to the danger of unforeseen accidents be sure to back up all GP screen data regularly After turning this unit OFF be sure to wait a few seconds before turning ON again If the unit
2. LCD B Touch Panel Runs any screen change operations and sends data to the PLC C Power Lamp Lights up when the power is turned On Green LED D Power Input Terminal Block c AB The input and ground terminals for AC power cable E Auxiliary Input Output AUX Operates the Touch Switch System Alarm Buzzer Run outputs and Remote Reset inputs F Serial Interface RS 232C RS 422 Serial interface Connect to the Host G Printer Interface Connect the printer here i H Tool Connector i Connect the Downloading Cable or a Bar Code D E F G H Reader here 2 Dimensions The drawings below illustrate the dimensions of the GP577R TC41 24VP unit unit mm Top View 301 263 Front View Side View 317 85 75 L775 J lt Z z i DE 211 2 Ei Serial Interface This is GP s serial port for RS 232C and RS 422 interface Connect GP s host here Pin Signal Pin Signal Name Condition 4 Nanna Condition 1 FG _ Frame ground 14 VCC eg Output SIE RS 2320 A RS 422 3 RD ee 16 RDB Roa B 4 RS eset 17 NC No connection s es gess el ose pe 6 NC No connection 19 ERB ac
3. is started within a few seconds it may not start up correctly UL cUL CSA Approval The GP577R TC41 24VP are UL cUL CSA recognized products UL file No E182139 E GP577R TC41 24VP conforms as a component to the following standards e EUL508 Industrial Control Equipment e UL1604 Electrical Equipment for Use in Class I and II Division 2 and Class II Hazardous Classified Locations e CAN CSA C22 2 Nos 142 and 213 M1987 Standard for Safety of Information Technology Equipment including Electrical Business Equipment GP577R TC41 24VP UL Registration Model 2780027 02 e The GP should be installed in the front face of a metal panel e Ifthe GP is installed so as to cool itself naturally be sure to install it in a verti cal panel Also be sure that the GP is mounted at least 100mm away from adja cent structures and other equipment otherwise the heat generated by the GP s internal components may become higher than that allowed by UL standard re quirements Installation and operation instructions are provided with each GP These installation instructions contain the following statements 1 Power input and output I O wiring must all be in accordance with Class I Divi sion 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 or as specified in Section 18 152 of the Canadian Electrical Code for units installed within Canada and in accordance with that location s authority 2 Suitable for us
4. To A WARNING When connecting a power cable to the GP unit be sure the cable has been unplugged from the power outlet so that you would not get an electric shock When replacing the backlight be sure to turn the GP power off and wear gloves to avoid burns or electric shock High voltage runs in the GP unit so if you take unit apart there is a danger of getting an electric shock Do not take the unit apart Do not use power beyond the specified voltage range If you do it may cause a fire or an electric shock Do not reconstruct the GP unit It may cause a fire or an electric shock Do not use the GP in an environment with flammable gas in the surrounding atmo sphere It may cause explosion GP use a lithium battery for backing up its internal clock data If the battery is incor rectly replaced the battery may explode To avoid the danger do not replace the battery yourself When the battery needs a replacement please consult with your local GP distributor Do not use touch panel switches in life related or important disaster prevention situ ations For safety related switches such as an emergency switch use a separate me chanical switch Please design your system so that the machine will not malfunction by a communica tion fault between the GP and its host controller If not there could be a danger of injuring a person or damaging materials Prevent From Damage Do not hit the touch panel with a hard or heavy object
5. d to hold the cable s set fastening screws in place 6 Installation Confirm the Installation Gasket s Seating It is strongly recommended that you use the gasket Place the GP on a level surface with the display panel facing downward Check that the GP s installation gasket is seated securely into the gasket s groove which runs around the perimeter of the panel s frame Installation Gasket CATAN e Before installing the GP into a cabinet or panel check that the Installa tion gasket is securely attached to the unit Cut a hole and mount the GP to the panel from the front Unit mm under 4 R2 302 0 5 es 1 6mm to 10mm S l a Panel thickness N a E Attach the Installation Fasteners from behind Fasten the screw of the installation fasteners with a screwdriver The fastening torque necessary for waterproofing is 0 5 0 6Nem CAUTION a e Tightening the screws with too much force can cause a damage 7 Wiring J N WARNING e To avoid electric shock be sure the Power Cable is unplugged from the power outlet when connecting the cable to the GP unit e GP577R TC41 24VP can only take DC24V input If you supply power other than DC24V you will damage its power supply and the GP unit e There is no power switch on the GP unit so please use a breaker switch O I 3 O When the FG terminal is connected be sure the wire is grounded Not grounding the GP unit will result in
6. e in Class I Division2 GroupsA B C and D hazardous location or nonhazardous locations only 3 WARNING Explosion hazard substitution of components may impair suitability for Class I Division2 4 WARNING Explosion hazard do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous 5 WARNING Explosion hazard when in hazardous locations turn off power before replacing or wiring modules CE Marking GP577R TC41 24VP are CE marked EMC compliant products These units also conform to EN50081 2 EN50082 2 directives 45 Package Contents The following items are included in the package Before using please ensure every thing is there i GPunit W Installation fasteners 4 pcs GP577R TC41 24VP H P W Handling guide 1 sheet this sheet Handling Guide This unit has been carefully packed with special attention to quality However should you find anything damaged or missing please contact your local GP distributor im mediately Extra Cost Options W Manual W Cables GP477R 577R Series W Adapters User s Manual W Screen editor software are optionally available Digital For more information see Digital s cata logues GP477R 577R Series User s Manual A Names and Functions of GP Parts Names and Functions of GP Parts are explained below A Display The monitor screen that indicates screens and data of the host GP577R TC41 24VP TFT type color
7. et as a Memory Link type and the cable type is RS 422 a 4 line system must be setup lt For RS 232C connection gt e Do not connect 9 TRMX 10 RDA 11 SDA 15 SDB 16 RDB 18 CSB 19 ERB 21 CSA and 22 ERA 4 Printer Interface This is the printer interface port in the rear side of GP unit PSTB E PDB4 When not using the INIT signal the 10 pin connection becomes unnecessary Recommended Connector FCN 787P014 G R lt manufactured by FUJITSU Inc gt Recommended Cover FCN 780C014 D E lt manufactured by FUJITSU Inc gt CAUTION e Do not connect to pin 12 and 13 FY AUX Interface Input Output An auxiliary interface for touch switch output system alarm output RUN output and remote reset input Name Touch Switch Output 8 bit 6 TSWs 8 Tsw Lh 4 Output On in RUN mode Off in standby mode or when the power is off 10 ALARM Alarm Output When On A feim alem ongni Output Common GND The AUX Alarm outputs in the following two cases e Hardware Alarm SCREEN MEMORY CHECKSUM ERROR e Software Alarm SYSTEM ERROR incorrect data that makes continuation of screen operation impossible Recommended Connector Dsub 15 pin Plug XM2A 1501 lt made by OMRON Corp gt Recommended Cover Dsub 15pin Cover XM2S 1511 lt made by OMRON Corp gt Jack Screw XM2Z 0071 lt made by OMRON Corp gt l MENO e Use rough metric type M2 6 x 0 45p threads use
8. excess noise and vibrations Ek m a e Wherever you can use thick wires max 2 mm for power terminals and provide an extra twist to the wire during connection J e Please use Ring Terminals with the size described below Over 3 2mm Under 6 0mm Cau e To avoid a short among the ring terminals when the screws get loosen please use ring terminals with a sleeve Rear side Ring Terminals 1 Power Input Terminal Block Ring Terminal to use V2 MS3 made by JST Connect the power cable following the steps below 1 Check to make sure the Power is Off 2 With a plus screwdriver remove the cover on the Power Input Terminal Block 3 Disconnect the screws from the 3 terminals to be used align the wire rings and re insert the screws Please make sure the connection of the wires are correct MEH e The torque necessary for fastening the screws is between 0 5 0 6Nem EJ Precautions for Supplying Power Please pay special attention to the following instructions when connecting the power cable to the GP unit e Ifthe supply voltage exceeds the GP unit range connect a voltage transformer e For between the line and ground select a power supply that is low in noise If there is an excess amount of noise connect a noise reducing transformer e When supplying power to the GP unit please separate the input output and operation unit lines e To increase the no
9. ise quality simply twist the power cable before connecting it to the GP unit e The power supply cable must not be bundled or kept close to main circuit lines high voltage high current or input output signal lines e Connect a surge absorber to deal with power surges e To reduce noise make the power cable as short as possible e After turning this unit OFF be sure to wait a few seconds before turning ON again If the unit is started within a few seconds it may not start up correctly 9 Precaution for Grounding e From the FG terminal at the rear side of GP unit please take grounding exclu sively within ground resistance of 100 Q 10 Precautions for Input Output Signal Lines e Input and Output signal lines must be separated from the power control cables for operational circuits e if this is not possible use a shielded cable and the shield should be grounded 11 Replacing the Backlight e The backlight on this unit can be replaced For an explanation of how to replace it please refer to the GP 477R 577R Series User s Manual sold separately or the instruction manual which comes with replacement backlights sold separately Applicable backlight models Backlight model GP577R TC41 24VP GP577RT BL00 MS CAUTION rE e Using any backlight other than the applicable models shown above may cause an accident or breakdown
10. s pi p 7 GND Signal ground 20 ER a o del e Taen 9 TRMX gee 22 ERA oua A 10 ADA e e AA 03 RESERVED o AR OES 11 SDA e A 24 NC No connection 12 NC No connection 25 RESERVED reserved for future 13 NC __ No connection Pin 14 can be used for the power supply for the user s optional equipment con nected to the GP Recommended Connector Dsub 25 pin plug XM2A 2501 lt made by OMRON Corp gt Recommended Cover Dsub 25 pin Cover XM2S 2511 lt made by OMRON Corp gt Jack Screw XM2Z 0071 lt made by OMRON Corp gt B MEMO o Use rough metric type M2 6 x 0 45p threads used to hold the cable s set fastening screws in place Recommended Cable CO MA VV SB5P x 28A WG lt madeby HITACHI Cable Ltd gt CATAN Pin 14 is not protected so be sure to use it only within its rated range e Be sure to connect this unit s SG terminal to the other unit s SG termi nal If necessary you may also need to connect the FG terminal to the other unit s FG terminal depending on the type of the other unit you use B MEMO When making a cable please be aware of the following lt For RS 422 Connection gt e The following pairs of pin s must be connected to each other 18 CSB lt gt 19 ERB 21 CSA lt gt 22 ERA e When connecting the RS 422 cable and the 9 TRMX and 10 RDA points a termination resistance of 100Q is added between RDA and RDB e When the GP is s